Home
TP-Link TL-SL3226P User's Manual
Contents
1. Ports Management Direction centric Sniffer Direction Disable Mode Sniffer Sniffer Port 1 Monitored Port Mask N A Flow centric Mode State Disable Sniffer Sniffer Port 1 Destination Port 1 Source Port 1 Port Description N A Port Statistics 0 Port BandWidth Ingress Control Disable Engress Control Disable Network IP Address DHCP Disable Parameters IP Address 192 168 0 1 Subnet Mask 255 255 255 0 Default Gateway 0 0 0 0 MAC Address table Max Age 300 Max Age Static MAC Address N A Table Filter MAC Address N A Spanning Tree Switch Configuration Spanning Tree Disable Bridge Priority 32768 Bridge Hello Time 2 Bridge Hello Age 20 Forward Delay 15 Port Configuration IEEE802 1x Protocol Switch Configuration Priority 128 all ports Path Cost 19 all ports 802 1x State Disable Authentication Method PAP Authentication Auth Server IP 0 0 0 0 Backup Auth Server IP 0 0 0 0 Auth Server Port 1812 Auth Server Key N A Acct Server IP 0 0 0 0 Backup Acct Server IP 0 0 0 0 Acct Server Port 1813 Acct Server Key N A Re Auth Enable Disable Re Auth Period s 3600 37 _ TL SL3226P EEP EEA EEO AAT IEEE802 1x Protocol Port Configuration State Disable all ports Force AUTH MAC Table N A Force UNAUTH MAC Table N A VLAN Management VLAN Mode Configuration IEEE802 1q Tag VLAN VLAN Configuration
2. TL SL3226P EEP EAE AEO AICO LU ATG 2 When downloading TFTP TFTP server must have the files for updating 3 Youmustguarantee the TFTP server in operating 4 To break the download is not allowed during the TFTP download Or else the Switch may be out of the way Save Reset When you reset to factory situation all parameters except IP address can be configured to factory configuration 4 4 2 Port Management clipz Hove an lt Euter gt Mule Se leet ivn Figure 4 4 Port Management Ports parameters In the IEEE802 1Q Tag VLAN mode there are two pages of port parameters as figure 4 3 and figure 4 4 In the figure 4 3 when the cursor is on the Speed Duplex the interface as figure 4 4 will exist when you move the cursor right Inthe Port VLAN mode or VLAN Disable mode there is only one page of port parameters as figure 4 5 The Port Security of Port 2 in the above figure is not configurable because 20 TL SL3226P RPS PACLO CIAL N Tt ATE the IEEE802 1X protocol of Port 2 has been configured to be Enable Please note Port Security Trunk and IEEE802 1X protocol are mutually exclusive In other word when you configure one of them other two can t be configured State The port can be used when the State is Enable while the port is prohibited when the State is Disable The Switch will discard the packets from the port e Port Security When you configure the Port Security of a port to b
3. All ports are in one VLAN whose VID is 1 Untag Trunk Configuration No Trunk IGMP Snooping IGMP Snooping set IGMP Snooping State Disable IGMP Snooping Age Time 120 SNMP Protocol Agent status SNMP Agent Status Enable Community Community Name Public Access Mode Read Write Host N A Trap N A Event None all items Priority Port Priority Priority Mode 802 1p all ports Priority Class Mapping Table Priority Class Mapping Low Priority Config High Priority Class Weight Low Priority Class Weight Delay Bound Mode OFF Low Priority Delay Bound Control Disable Low Priority Delay Bound Time Security 38 Security Configuration User Name Supervisor Password Supervisor User Type Admin State Enable
4. Remarks e Pay attention to the stability when you put the TL SL3226P It s serious ifthe TL SL3226P drops 10 TL SL3226P EE EEA EET e The TL SL3226P can start to work with the correct power supply Please confirm whether the power supply is accordant to the requirements of the TL SL3226P In order to avoid the risk of the power attach don t open the shelf of the TL SL3226P when it works Don t open the shelf even without power When the TL SL3226P is connecting with the working stop server hub or other switches the network cord must be less than 100m if the network cord is UTP e You must use Cat 3 or above UTP for 10Base T Ethernet e You must use Cat 5 UTP for 100Base TX Ethernet e The module decides the operating speed of the extension slot The 100M Module can work in 100M situations while the 1000M modules can work in 1000M networks e When the TL SL3226P is working the network cord can be put into the port or put out from the port randomly without breaking the operating of the TL SL3226P e Before clean the TL SL3226P please unplug the power adapter Don t clean with liquid e Don t put the TL SL3226P near water or humidity avoid water or humidity air into the shelf e Avoid the dust and strong electromagnetism Chapter4 TELNET Out of Band Management 4 1 Introduction Through TELNET you can realize Remote Log in to manage the Switch 11 _ TL SL3226P 624 2GGigabitM anaged Switc
5. The Spanning Tree protocol includes the Switch configuration Open Close Spanning Tree Network Bridge Priority and port configuration Such as port priority situation IEEE802 1X protocol includes Switch configuration port configuration force authorized table force unauthorized table and authorized address table VLAN Management includes VLAN mode configuration Port based VLAN IEEE802 1Q Tag VLAN and VLAN Disable VLAN configuration and MTU VLAN team Trunk Configuration is to configure and check Trunk IGMP includes IGMP Snooping Set and IPMC Group Member Info SNMP protocol includes SNMP agent situation SNMP team name table such as access mode situation SNMP host table such as IP address team name situation SNMP Trap purpose table purposed IP address port situation and SNMP system event Priority Management includes Port priority priority mapping and priority configuration Security Configuration menu is used to configure the user managing the Switch such as user s name password situation Help is used to check the usage of kinds of control button such as direction button TAB button 16 TL SL3226P EEP EEA EEO The assumpsit of normal control button in the operating interface is as following lt Arrow Key gt Direction Button up down left right moves cursor lt Tab gt Tab Button move the cursor to the next stay place lt W gt lt w gt W w Button move the cursor u
6. MAC address can t be set into the Force UNAUTH MAC Table Static MAC Address e Filter MAC Address Force UNAUTH MAC Address e Authorized MAC Address 4 4 6 VLAN Management NAN Ma trasane init gt gt ULAH Nude yusa ULAN Cont iguratian ATI UTAN Genep Rach Tu Main Mim 4Up Dound Move uraa singar Heke Salsccion Figure 4 8 VLAN Management Se Remarks 1 When the VLAN mode has been changed the Switch will reboot automatically 27 _ TL SL3226P RPS SPACLO CHAU Tct AAT 2 When you configure the MTU VLAN and effect it all original VLAN and Trunk configuration will be cancelled 4 4 7 Configure Trunk Jaunk VarSdjuratian iwye Lof gt 1 11112333322 OD I me l ee ee eee Sere ia sble Wacrbis I 1 i s Warrbis 1 s Virbi 1 War rbis 1 i Wibi Wasebie Figure 4 10 Configure Trunk Page 2 of 2 Ee Remarks 1 Trunk Configuration Regulation The Switch supports 7 Trunk 24 normal ports can only form Trunk with the normal ports Two modules with same model can form a Trunk But the module slot can t form Trunk with the normal ports There must be from 2 to 4 ports to be a Trunk e The Trunk will be treated as a logistic port after you seta Trunk 28 TL SL3226P RPS SPACLO CHAU N Tt AATE 2 When you configure a Trunk the ports added to the Trunk will be deleted from all VLANs no matter whether you create a
7. The internal power system of the TL SL3226P can automatically adjust the screws provided 2 Slide the TL SF3226P into the Rack 3 Use the screws to secure the TL SL3226P to the Rack operating power pressure according to the power pressure input The POWER LED willbe light when power on JN Caution As a precaution in the event of a power failure unplug the switch When the power resumed plug the switch back in TL SL3226P RPS SPACLO CHAU LN Tt AAT 3 2 Connecting the Switch 3 2 1 Front Panel There are 2 extension module slots 24 10 100Mbps ports one console RS232 port and LED indicators on the front panel of the TL SL3226P Slot a AA A A ibit Managed Switeh Figure 3 2 Front Panel of the TL SL3226P Module Slot The module slots can connect 100M 1000M module card and GBIC card e 24 10Base T 100Base TX RJ 45 ports All ports can auto negotiate between 10Mbps or 100Mbps and full or half duplex You can configure the speed duplex mode flow control broadcast storm control and security control through kinds of manage ment way such as SNMP Web Telnet or Out of Band management There is one LED on each side of every port Link Act LED on the left is green 100Mbps LED on the rightis orange Link Act 7 100M Figure 3 3 one port of the TL SL3226P e Console port The Console port or R
8. Addewce Table Rack Th Nadin Menu lt Up Boun gt Mowe Cursar Ribkwe gt Aaka See lord inne Figure 4 5 Network amp Remarks 1 Max Aging Time Dynamic forwarding table entries which aremade up of the source and destination MAC addresses and their associated port numbers are deleted from the table if they are not accessed within the aging time The aging time can be from 300 to 765 seconds A very long aging time can result in dynamic forwarding table entries that are out of date or no longer exist This may cause incorrect packet forwarding decisions by the Switch If the Aging Time 24 TL SL3226P RPS SPACLO CDLAC N Tt ATG is too short however many entries may be aged out too soon This will result in a high percentage of received packets whose source addresses cannot be found in the forwarding table in which case the switch will broadcast the packet to all ports egating many of the benefits of having a switch Static forwarding entries are not affected by the aging time 2 Static MAC Address If you set the wrong port of the address or change the port during operation you must reset the Static MAC Address Table Or else the address can t be used After you configure the Static MAC Address the Switch can t operate normally if a equipment with this address connects to the other port of the Switch It s better to delete the static address which won t be used when you configure the static MAC addr
9. Or Figure 3 5 Module of the TL SL3226P as the following figure D TX RX O Link Act 10 100M FDX Col When you install any of the modules you must turn off the power at first After you take out the board on the slot put the module into the extension slot The TL SL3226P can auto identify the module and configure automatically The TL SL3226P can use with TL SM201 100M series modules TL SM301 Gigabit series modules and TL SM301GB GBIC cards TL SM201 100M Series Module TL SL3226P 624 2GGigabitM anaged SwitchUser s Guide Model No Standard Interface Network Media Maximum Transfer Distance TL SM201U 100Base TX RJ 45 Cat 5 UTP STP 100m TL SM201CM 100Base FX SC 50 125 um MMF 62 5 125 um MMF 2000m TL SM201CS 20 100Base FX SC 9 125 um SMF 20000m TL SM201CS 40 100Base FX SC 9 125 um SMF 40000m TL SM201CS 60 100Base FX SC 9 125 um SMF 60000m e TL SM301 Gigabit series module A Caution The extension slots with UTP module can support auto negotiation and auto Model No Standard Interface Network Media Maximum Transfer Distance TL SM301U 1000Base T RJ 45 Cat 5 UTP 100m TL SM301CM 1000Base SX SC 50 125 um MMF 62 5 125 um MMF 550m TL SM301CS 1000Base LX SC 9 125 um SMF 10000m MDI MDIX These two slots are independent never conflicting with other normal ports 3 3
10. S232 port on the right of the front panel is the _ esieyrata 24 2GGigabitM anaged SwitchUser s Guide connection port with PC when Out of Band management Power LED Located between the console port and 24 normal ports the power LED will be always green when power on Or else please check the power connection e 100Mbps LED Speed LED When anormal port connects to 100Mbps equipment the responding LED is orange An unlit LED indicates a connection speed of 10Mbps e Link Act Connection LED The LEDs are lit when there is a secure connection to a device at any of the ports The flash LED indicates data transmission at the responding port 3 2 2 Rear Panel The rear panel of the TL SL3226P contains a power connector and a port for ground connection 10 280V spans oaa Figure 3 4 the Rear Panel of the TL SL3226P Power connector The AC power connector is a standard three pronged connector that _ TL SL3226P RPS SPACLOI CDLAC Nit AATE supports the power cord Plug in the female connector of the provided power cord into this socket and the male side of the cord into a power outlet Supported input voltage range from 110 to 260VAC at 50 60Hz The port for connection to the ground There is a porton the left of the panel for the connection to the ground 3 2 3 Optional Extension Modules There are two module extension slots on the front panel of the TL SL38226P O
11. SL3226P 624 2GGigabitM anaged Switch User s Guide 10HD 10Mbps Half Duplex 10FD 10Mbps Full Duplex 100HD 100Mbps Half Duplex 100FD 100Mbps Full Duplex 1000HD 1000Mbps Half Duplex 1000FD 1000Mbps Full Duplex Default VID There is this choice only in the IEEE802 1Q Tag VLAN mode Every port on the Switch has a Default VID which is the VID for an Untag Tag received by the port e Drop Untag Frm One of the input regulations of the Switch When you configure it to be Enable the Switch will discard the Untag Tags e Drop Nonmbr Frm One of the input regulations of the Switch When you configure it to be Enable the Switch will discard Unmember Tags Port Sniffer There are two modes of Port Sniffer Direction Centric Mode Sniffer and Flow Centric Mode Sniffer Please note these two modes can t be Enable at the same time When you use one of two modes you can t use another The Trunk member port can t 23 _ TL SL3226P 624 2GGigabitM anaged SwitchUser s Guide be a sniffer port The Sniffer port should in a same VLAN with the mirrored port Direction Centric Mode Sniffer Sniffer Port can choose any port from port 1 to port 26 but it can t included in the mirrored port Port 25 and Port 26 can t be used if there are no modules inside 4 4 3 Network Hotwork gt gt IP Mihira Persant lt lt HAC Addwau Table Nax Aye Dymanic MAC Address Table Etarir MEG Addwean Tahir Filter MAC
12. TP LINK SHENZHEN TP LINK TECHNOLOGIES CO LTD Tel 86 755 2661 2350 2652 5723 Website http www tp link com Add Fl 3 Bldg R1 B High Tech Industrial Park Shennan Road Shenzhen China E mail export tp link com cn OL H 999 aae TP LINK users Guide TL SL3226P 24 2G Gigabit Managed Switch Trademark Copyright statement TP LINK is the registered trademark of Shenzhen TP LINK Technologies Co Ltd All rights reserved contents may be revised without prior notice No part of this publication may be reproduced in any form or by any means or used to make any derivative such as translation transformation or adaptation without permission from Shenzhen TP LINK Technologies Co Ltd See our web site for more details http Awww tp link com _ Table of contents CMECKIIST 2 c5 cca ce itesieasscce contanaceaige e ae AA A a E ORE EE AE EEE 1 Chapter 1 About this User s Guide osseesseesneeneeresrneerreenneenneena 1 lel USIOE a e aia aa 1 12 ASSUMPSIE cneid ea E eas 1 1 3 Overview of this User s Guide eee eee eeeeeeeeneeteneeeneees 2 Chapter 2 INtroGuction ee eee eeeeeeeeececeenecesnereseeeeeeeessaneeeeeeeeeneners 2 231 Overview Of the product i ccieis2 d ssetedeseaekedgegahegtegeieddsneadoeasts 2 2 2 Features and Specifar 3 22 f 110 2 en ee ee eie e 3 22 2 SPCC CATON peie cae csecebdenaas tcdecendedees dash cuseladehcent ccenesdean 4 Chapter 3 Installation eee cece eee
13. Trunk or add the port to a Trunk If you delete any port or delete the whole Trunk the original port in the Trunk can t reset to any VLAN In the begging of creating a Trunk the Trunk is not along to any VLAN You must configure it to the required VLAN according to the requirements Chapter5 WEB Management 5 1 Introduction The TL SL3226P offers an embedded Web based HTML server allowing users to manage the Switch from anywhere on the network through a standard browser such as Microsoft Internet Explorer The Web based management module and the Console program and Telnet are different ways to access the same internal switching software and configure it Thus all settings encountered in Web based management are the same as those found in the console program 5 2 Connection of WEB Management 5 2 1 Getting Start The first step in getting started in using Web based management for your Switch is to secure a browser such as Microsoft Internet Explorer Simply called IE Furthermore the browser must support Javascript Script For the best effect we suggest you to use IE5 0 or above version and 800x600 or above system 29 _ TL SL3226P RPS SPACLO CIAL Tt iN ACG LU MRT Before getting start you must finish some preparing steps We choose IE 5 0 in Windows 2000 to be an example The First Step Toolin the IE menu Internet options the following screen axi General enir Content Connections Progr
14. ame A venced Hore pzge 2 Fiu cin change whic page to 50 for yo_t ONI pace I au fddrees http az tonk cr cn Lscnurn Use Lefa l Lee Bank Tenzovsty Inzernst les iz A Peges yan wes or he ternet acs darer in peris Fider E ij fur quik viewing aler Hetor y a OT e bisbury fdha cu lans iks lu pays you ve viile fur ca it aczess to ecer tly viese paces Dave bo kezp pages I hEtorv Ja eat Hstury Lgo FIOS AMUJI PECORI y o CK Ianca Apae Figure 5 1 Internet Options The Second Step Press Settings to the following screen 30 _ TL SL3226P EEP EE AEE AAT kaka f Ng Check for newer ve sicns of stored pages C Every visi tc ths page Temporary Internct Files older Gurrentlocation C Cocumerts anc sectngsiAdmn stratoriLoca Seli gs Tempur ary I lem Fits Arront of ds4spaca to use e 127 ME 1 Move Fulder View Fics View Objetls owa Figure 5 2 Settings Please choose Automatically then press OK The Third step Choose Security User defined 2 x Genwal a ontert Tonnertinre l Progra l zwenred zocc a web Torben anz be spzefy its szcurty szttings Inczernst oca l tramet stez clzzs Resirktez shes Internet The sne ua lans sl wee siz yuu havent placad I other co e berurby vd for ths zone Move the aldzt bo ze the sesurty level for ths zone Me
15. d D abts E o a Partye Noe o Stop bits i gf Ilow cortot Nore M Reslue D faulls H Fante Lpaly Figure 4 1 Console configuration The speed of the console port is 9600bps The data bit is 8 bit There is no Parity Test and flow control The Stop bitis 1 If there is no HyperTerminal in the system you can setup the HyperTerminal software from the system setup disk or download from the website such as 13 TL SL3226P EEP EEAO AICO LU mR INTL HyperTerminal Private Edition The configuration way is similar with that on Windows 4 4 Theinterface and operating way of TELNET Out of Band No matter through TELNET or Out of Band Management the users have two rights e Admin the control right to manage the Switch e Guest the read right for part of objects Admin visits AN Caution Since Guest account has the read right only for some pages there will be a prompt to remind the user no right for reversion when the Guest account want to configure the active the Switch When the account wants to enter SNMP menu Security menu IEEE802 1X protocol menu file transmission menu and reset menu of the system configuration menu the account will be reminded no right to enter Because the basic content of TELNET and Out of band Management through the Console port is as same as each other we introduce them together After you use the correct user s name and password the default user s nam
16. diu Sdr lmi yt ls 17 n tina Pia pls bafwe Luo loading pleididiy urea uwiii U signzd Acte comtrok wil not ze dosnozdzd Azpprate 2e nast Internet stes CK Ianca Pople Figure 5 3 Security 31 TL SL3226P EEP EEA EEO AICO LU MMOL The Forth Step Choose Enable in the Active Scripting or choose Reset to Medium press Reset and press OK Security Settings 2x Selis E Surili B active scaptna bVizatle Fnahe Promat Ei Allow gt aste operations via scr p Disatle Encbe O Fromat 4 Scripting of Jeva asplets Disalle Enade i Promat rase custom settings Reset to rezum x Resel ae Figure 5 4 Security Settings The Fifth step Press the right button of the mouse choose Propertiesin the menu existed The following screen will exist Choose Settings set 800x600 press Apply or OK 32 _ TL SL3226P RPS SPACLO CDLAC Nit AAT alzi Beoego n Szrzo Saver Appearance Web Etoc Suna Y E spas C zfaut onto cn Inve Cirzo ation 210 S azhes Cowoler 4 b Li les liee sma bus lee 24 r lass Figure 5 5 5 2 2 Connection We propose the IP address of the Switch is 192 168 0 2 you can input http 192 168 0 2 in the IE to connect the Switch Then press Enter the following screen will exist axl fog ras tyre your se nemne and password f xe 197 IRA NF Rear gt AER WN dia hans enera Barsd Fig
17. e and password are supervisor you will log on the interface of TELNET Out of Band Management 14 TL SL3226P EE EEA EET The management interface is the menu drive After you log on you will in the first menu as following TP T TNK TL 1 2226P Moin Menu 22 Systen Canfisuratian C lt Parr Management Nulwurk Spanning Iree Protocol EEERHZ d Piwka ULAN Managenent Tmmk Canfiguratian IGMP Siwupiny SHNI Protocol ily He Luguut SMD gt Merwe Cesc cInter gt Moke Figure 4 2 Main Menu e Illumination System Configuration includes system information such as software hardware version module information switch parameter such as broadcast storm filter mode file transmission save and reset Ports Management includes port parameter open close flow control port default VID port security port mirror two types direction mode mirror and flow mode mirror port description use character string to describe ports port statistic the statistic information of tag forwarding receiving and conflicting port situation connection situation port speed duplex mode and port bandwidth entrance bandwidth and exit bandwidth Network includes address parameter the Ethernet address of the Switch IP address NetMask Gateway etc maximum aging time Dynamic address 15 _ TL SL3226P RPS PACLO CIAL Tt iN ACG RUS mR INTL table static address table and filter address table
18. e Enable the port won t learn any new MAC address Furthermore the port only transfers the Data Tag accordant to requirements OtherTags will be discarded When the Port Security of a port is Disable the port will automatically learn any new MAC address and transfer Tags received Flow Control Disable default The port won t produce Flow Control packets and will discard the Flow Control packets received Enabled The Switch will negotiate Flow Control on the specified port according to Full Duplex or Half Duplex Speed Duplex 10Base T 100Base TX ports Auto default auto test the speed and negotiate the duplex mode with the other end 10HD 10Mbps Half Duplex 21 _ TL SL3226P EEP EAE AEO AICO LU mR INTL 10FD 10Mbps Full Duplex 100HD 100Mbps Half Duplex 100FD 100Mbps Full Duplex Two independent modules The operating mode of two independent modules is different according to different module There are four types of the modules 1 100M fiber module such as TL SM201 series Auto auto negotiation 100FD 100Mbps Full Duplex 2 100M Twisted Pairmodule such as TL SM201U Auto auto negotiation 10HD 10Mbps Half Duplex 10FD 10Mbps Full Duplex 100HD 100Mbps Half Duplex 100FD 100Mbps Full Duplex 3 Gigabit FiberModule suchas TL SM301CS Auto auto negotiation 1000FD 1000Mbps Full Duplex 4 Gigabit Twisted Pair module such as TL SM301U Auto auto negotiation 22 TL
19. e MIB TP LINK LED Power Power on Enterprise MIB indicator Each port Two indicators Link Act and 10 100Mbps ne Dimension 440mm X 260mm XxX 44mm W x H x L e Support RMON Statistics History Alarm and Event group Environment Operating temperature 0 C 40 C Support IEEE802 1D Spanning Tree protocol Storage temperature 20 C 70 C Operating humidity 10 90 RH Storage humidity 5 90 RH and connect to RADIUS Power 110 260V 50 60Hz e Support IEEE802 1X Port Based Network Access Control protocol _ TL SL3226P EEP EE AEE ATE TL SL3226P EEP EAEE AAT Chapter3 Installation 3 1 Installation Follow these steps to install the switch 5 e The surface must support at least 5kg Nese i piee pn e The power source must be within 1 5m B e Check the power cable to make sure the connection to AC power o e Leave enough space for the ventilation o p 3 1 1 Desktop or Shelf Installation Ae Put the TL SL3226P on the big and stable desktop bottom up 2 Attach the cushioning feet on the bottom at each corner of the device 3 Upturnthe device putit on the desktop Figure 3 1 Rack Installation 3 1 3 Power On The TL SL3226P can be used with the power source in the range of 110 to 260VAC 50 to 60Hz 3 1 2 Rack Installation The TL SL3226P can be mounted in an EIA standard size 19 inch rack ils Attach a mounting bracket to each side of the TL SL3226P with the
20. eeeeeeeeeeeeeeeeeeaeeseseeeeseneeenneees 5 6S Stalai Meere a E rere eeteercer er er ereerrre rest 5 3 1 1 Desktop or Shelf Installation eee eee eeeeeeeeeeeeeneeeeneeeeneees 5 Bv 2 Rack Installationsccseccicth gnisninger 5 SiS POWG OM iene ihren uk aeration es eee ce tee ee eel eee Seah 6 3 2 Connecting the SWItCH eee eeeneeeeeeeteeeeeteeeeteeeeeaeeees 7 3 2 Eront Panolu ae ae O ee a e eee e 7 3 22 Roar Panola genieeo i a eee ieia ai 8 3 2 3 Optional Extension Modules eee eeeeeeeeeeeeeeeeeeeeeeeeneeeeneees 9 3 3 RomarkS sorok neeaae ae a sures aA Ao OAE AA E 10 Chapter 4 TELNET Out of Band Management cceeeeeee 11 AM WAMOGUCHOM aini ei n eis 11 4 2 Howtoconnect TELNET cccccceeeecceccceseeeeeeeeeeeeeseeaeeeeees 12 4 3 How to connect Out of Band eee eeeeeeeeeeeeeteeeeeeeeeeeaes 13 4 4 The interface and operating way of TELNET Out of Band 14 4 4 1 Configure SYSteM c ce eeeeeeeeeeeeeeeeeeeeeeeeeeeeeeaeeseeeeeeeeensaeeeeaes 17 4 4 2 Port Management riescia a 20 4 4 3 NOWO K oossoo eaaa eaen ea a gE 24 4 4 4 Spanning Tree protocol ssesssesseessiessreesreesrernnsennsrnnsrnnsrnnsnnnne 25 4 4 5 IEEE802 1X Protocol koitetun ieithog ananuna nsa 26 4 4 6 VLAN Managemernt seesseeseessesseesrnesrnesrnesrneernsernsennsennsennnrnne 27 4 4 7 Configure Trunk sssseeeeseeeieeriesiresiesiresiierirerrnsrrnsrenerenereeereeet 28 Chapter 5 WEB Management eeeeseeeseeeereeererrre
21. ess 4 4 4 Spanning Tree protocol Hock Lo Main Menu Up Down Move tuxrcor an cud Hy ir Boon Enkard Makna Salaction Figure 4 6 Spanning Tree protocol Remarks There are limits as following 25 _ TL SL3226P 624 2GGigabitM anaged SwitchUser s Guide Priority 0 65535 Hello Time 1 10 Maximum Age Timer 6 40 Forward Delay Timer 4 30 Max Age lt 2 x Forward Delay 1 second Max Age 2 x Hello Time 1 second When the Spanning Tree changes from Disable to Enable the port will be blocked for a while which is two times of the Forward Delay After revision you must TELNET the Switch again There are limits to the Port Priority and Port Cost Port Priority 0 255 can configure 1 and 255 Port Cost 1 65535 can configure 1 and 65535 4 4 5 IEEE802 1X protocol LEEW 1x Preotucul gt gt Switch Canfiguration lt lt Furt Cont iyurat ivu Foaree AMTH MAC Tahle Force UNAUTH NAC Table AUTIILD MAC Details Beck Tu Hain Nenu lt Up Down gt Move Gurser SEnter gt Make Select ive Figure 4 7 IEEE802 1X protocol Remarks The following MAC address can t be set into the Force AUTH MAC 26 TL SL3226P EE EE AEEA Table e Static MAC Address Filter MAC Address e Force UNAUTH MAC Address e Authorized MAC Address 2 No matter which port the MAC Address of the Force UNAUTH MAC Table relates to the Switch won t transfer its packets The following
22. hUser s Guide Out of Band Management manages the Switch locally through the console port without occupying the bandwidth Though TELNET and Out of Band have different presentation their management contents are same Both of them are to configure the Switch s characters 4 2 Howto connect TELNET Connect the management workstation to the management port on the Switch You can directly use TELNET commend on the commend DOS promptin the Windows Attachment The parameter following the TELNET commend is the IP address of the Switch which can be revised to adapt to the network However when you reuse TELNET to access the parameter will be the Switch s IP address newly set There is limit to the users accessing times through TELNET maximum 3 times There is also time limit for the connection The connection will be automatically broken if there is no operation in a limit time Furthermore maximum 5 users can access to the Switch through TELNET at one time Remark Only the PC connecting to the management port can configure the Switch through TELNET or WEB 12 _ TL SL3226P EEP EEA EET E 4 3 Howto connect Out of Band Out of Band Management needs a terminal or a HyperTerminal First connect the Switch s console port with the PC s console port by the console cord Then run HyperTerminal Refer to the following figure to configure the HyperTerminal ax Port Settirgs Bts per second feeoo ti
23. how to manage the switch through TELNET Out of Band Management Chapter5 WEB Management AnnexA RJ 45 Plug Connector Pin Specification Annex B Default Configurationof the switch Chapter2 Introduction 2 1 Overview ofthe product TL SL3226P switch fully complies with IEEE802 3 Ethernet standard its standard 19 inch size and intelligent management make it suitable for small middle and large networks TL SL3226P switch provides powerful management functions including the system port network Spanning Tree protocol IEEE802 1X protocol VLAN Trunk IGMP Snooping SNMP protocol priority and security etc TL SL3226P switch provides multiple management method SNMP Web Telnet and Console RS232 TL SL3226P switch provides two independent extension slots which support 100 1000M module card and GBIC This modular structure protects user investment and makes the switch more versatile _ TL SL3226P PCS SPACLO CHALICE N Tt iN AICO US mR ONT 2 TL SL3226P RPS SPACLO CIAL Tct AATE 22 Features and Specification Support static priority and IEEE802 1p class of service with 2 level riority mode 2 2 1 Features pene Fully comply with IEEE802 3 standard e Full and half duplex for both 10Mbps and 100Mbps connections e Support Static MAC address management and MAC address Binding e Provide the configuration function of port security broadcast storm a control and port sniffer e Support IEEE802 3x flow control for full duple
24. mation 1 Ifyou use modules you can configure the responding module slot Slot1 Port25 Slot2 Port26 2 Ifyou install modules the module information will be showed according to the specific modules 100M UTP module 100BASE TX 100M Fiber module 100BASE FX Gig abit UTP module 1000BASE T Gig abit Fiber module 1000BASE LX SX 18 TL SL3226P EEP EE AEE AT Switch Parameters 1 Assigned Managed Port can be any port or all ports from P1 to P26 Only the workstation connecting to the Assigned Managed Port in the Switch can manage the Switch The default is All ports 2 Broadcast Strom Filtering Mode have six choices 5 10 15 20 and 25 3 The configuration of parameters won t be effect until you activate the changes When you press Ctrl U the Switch will list Are you sure you want to activate the changes Y N Y for confirmation N for cancel e File Transfer 1 Transfer types are Update System Backup Switch Config and Updata Switch Config Updata Switch System Through the program files using by TFTP server to update the Switch download the program files provided by TFTP server into the Switch to realize the software update Backup Switch Config Upload the configuration files of the Switch to TFTP server to store the configuration parameters of the Switch Updata Switch Config download the configuration files for the Switch from TFTP server to update the Switch configuration 19 _
25. p lt S gt lt s gt S s Button move the cursor down lt A gt lt a gt S s Button move the cursor left lt D gt lt d gt D d Button move the cursor right lt Esc gt Esc Button exit the current menu lt Enter gt Enter Button enter the next sub directory or active the revision lt Space gt Space Button switch the choice lt Backspace gt Backspace Button delete one letter lt U gt press U button after press Ctrl button Ctrl U active the revision data lt A gt press A button after press Ctrl button Ctrl A choose all letter where the cursor locates Remark The revised configuration won t be effect without activation The effect configuration is effective before the next startup In order to effect the configuration after next startup you need to enter into the SAVE and RESET menu of System configuration menu to save the configuration 4 4 1 System Configuration 17 _ TL SL3226P RPS SPACLO CALI LCITt iN ACG LU mR TTL 2 Susten Canl iyuration 3 Susten Information lt lt Hndiilre Infarmatinn Suitch Parameters Fale Transfer Save Reset Dack Io Main Nenu 4ilp Dnun gt Hnue Cian lt Entar Moke Selsction Figure 4 3 System Configuration CS Remarks System Information When you configure System Information only System Name System Contact and System Location can be changed Others of System Information are only for read Module Infor
26. rriereereereeresreee 29 SA NrodUCtON iseiti ane a id 29 5 2 Connection of WEB Management eeeeeeeeerreererrrerreereeree 29 Annex A RJ 45 Plug Connector Pin Specification 0 ee 34 Annex B Default Configuration of the SWitCh eee 36 TL SL3226P RPS SPACLO CDLAC N Tt WN AICO U MRI s Checklist Open the box and carefully unpack the TL SL3226P You should have all the items on the following checklist One TL SL3226P Switch e One AC power cable One Serial cable One User s Guide CD or Presswork e Two mounting brackets and screws If any item is missing contact the retailer where you purchased the TL SL3226P for assistant Chapter1 Aboutthis User s Guide Thank you for purchasing TL SL3226P 24 2G Gigabit Managed Switch The TL SL3226P provide powerful management functions With the features of high performance easy to use and economic the TL SL3226P is the ideal choice for you 1 1 Usage This User s Guide tells you how to use your TL SL3226P 1 2 Assumpsit The TL SL3226P indicated in this User s Guide is the TL SL3226P 24 2G Gigabit Managed Switch _ TL SL3226P 624 2GGigabitM anaged SwitchUser s Guide 1 3 Overview of this User s Guide Chapter1 Aboutthis User s Guide Chapter2 Introduction Describes the switch and its features Chapter3 Installation Helps you to get started with the basic installation of the switch Chapter4 TELNET Out of Band Management Describes
27. t used Not used 5 Not used Not used 6 RX receive TX transmit 7 Not used Not used 8 Not used Not used Table A 1 The standard Category 3 cable RJ 45 pin assignment The following Figure shows the facture of the Straight Cable and the Cross Cable Straight Cable The Switch Uplink port or NIC connects to equipments normal ports Figure A 3 Straight Cable the switch hub other 35 _ TL SL3226P EEP EAEE iN AICO RUS mR TILT Cross Cable The Switch normal port connects to the switch hub other equipments normal port MDI X MDI X Figure A 4 Cross Cable Usually the Straight Cable is required to connect to the switch Uplink Port or NIC Annex B Default Configuration of the switch System Configuration System Information System Name TL SL3226PVXX System Position New Location Contact Administrator Switch Parameter Assigned Managed Port All Ports Broadcast Storm Filtering Mode OFF File transfer Transfers Type Update System File File Name sl3226p bin TFTP Server 0 0 0 0 Ports Management 36 Port Parameters State Enable Port Security Disable Flow Control Enable Speed Duplex Auto Drop Untag Frm Disable Drop NonMbr Frm Disable Default VID 1 TL SL3226P EE EEA EEO ATE
28. ure 5 6 33 TL SL3226P 24 2GGigabitM anaged SwitchUser s Guide Input the user s name and password the default user s name and password are supervisor Furthermore the default user has managing right Press OK to the page of WEB management JN Caution The default user s name and password are set in factory You can revise and add user s names and passwords in the Security Configuration You must have management right when you revising such configuration If you reset the Switch to factory configuration all users names and passwords set before will disappear There is only default user s name and password Like TELNET WEB has two managing rights Manager s right and user s right Annex A RJ 45 Plug Connector Pin Specification When connecting the Switch to another switch a bridge or a hub a normal cable is necessary Please review these products for matching cable pin assignment The following diagram and table show the standard RJ 45 receptacle connector and their pin assignments for the switch to network adapter card connection and the normal cable for the Switch to switch hub bridge connection Figure A 1 The standard RJ 45 receptacle connector 34 TL SL3226P EE EEA EEO AATE RJ 45 Connector pin assignment Connector pin assignment Contact MDI II Signal MDI X Signal 1 TX transmit RX receive 2 TX transmit RX receive 3 RX receive TX transmit 4 No
29. x mode and collision Provide per port egress ingress rate control function and the minimum based backpressure for half duplex mode granularity is 64kbps Use non blocking store and forward shared memory architecture e Provide static IP address configuration and dynamic IP parameters by e 24 10 100BaseT TX RJ 45 ports with auto MDI MDIX en e Provide 2 independent extension slots support 100 1000M module e Support firmware upgrade configuration backup and restore by TFTP card and GBIC Support the port N Way auto negotiation function automatically 2 2 2 Specification negotiate the speed and duplex mode between two devices e Provide 6K MAC address space Standard Compliant with IEEE802 3 IEEE802 1D s F IEEE802 1Q and IEEE802 1X e Support MAC address learning and aging with programmable age Eon 24 10 100M RJ 45 ports with auto MDI MDIX time 2 independent 100 1000M extension slots e Provide IGMP snooping function One console port RS232 VLAN Mode IEEE802 1Q VLAN mode Provide maximum 26 port based VLAN and 256 IEEE802 1Q VLAN Port based VLAN mode e Provide maximum 7 trunk groups of up to 4 member ports within 26 Network Medium 10Base T CAT 3 or above CAT 3 UTP STP 100Base TX CAT 5 UTP STP parts 100Base FX MMF SMF e Provide SNMP Web and Telnet Console management 1000Base T CAT 5 UTP STP e Support SNMPv1 SNMPv2c LONER ase se MMF 1000Base LX SMF or MMF e Support SNMP MIB II Ethernet like MIB Bridg
Download Pdf Manuals
Related Search
Related Contents
Exacompta 542572E ring binder BenQ MX600 Quick Start Manual POMPES VERTICALES POUR FORAGE Samsung SGH-D838 用戶手冊 Mode d`emploi 『かまど大火力』と『鍛造厚釜』で、 ふっくら炊き上げ。 Feldbusse für SINAMICS G120, G120P, G120C - Service cp color mh Mode d`emploi Trancheuse universelle MASTER M 80 Computer Gear 20m 3.5mm - 3.5mm Copyright © All rights reserved.