Home

Teka DCT60 User's Manual

image

Contents

1. 10401257250 01 Manual de Instrucciones CAMPANA DECORATIVADCT 60 DCT 90 Einbauanleitung und Pflegehinweise DUNSTABZUGSHAUBEN DCT 60 DCT 90 Instruction Manual CHIMNEY HOODS DCT 60 DCT 90 Instructions pour le montage HOTTE CHEMINEE DCT 60 DCT 90 Manual de Instruc es CHAMIN S DECORATIVASDCT 60 DCT 90 Instrukcja Montazu KOMINOWY DCT 60 DCT 90 D FIG 3 J MONTAJE SIN SOPORTE n BEFESTIGUNG OHNE BEFESTIGUNGSBUGEL INSTALLATION WITHOUT BRACKET MONTAGE SANS BARRE MONTAGEM SEM SUPORTE MONTA BEZ WSPORNIKA SOPORTE DE SUJECI N DE LOS TUBOS BEFESTIGUNGSBUGEL FUR DIE SCHACHTE TUBES FIXING BRACKET BARRE DE FIXATION TUBES SUPORTE DE FIXA AO DOS TUBOS WSPORNIK DO MOCOWANIA PRZEWODOW RUROWYCH FIG 4 ORIFICIOS PARA COLGAR LA CAMPANA BEFESTIGUNGSL CHER F R DIE HAUBE HOLES FOR THE HOOD FIXING TROUS POUR ACCROCHER LA HOTTE FUROSPARA PENDURAR A COIFA OTWORY DO ZAWIESZANIA OKAPU ORIFICIOS DE SUJECI N DE LA CAMPANA 8 mm SICHERUNGSLOCHER 8 mm FUR DIE HAUBE HOOD FIXING HOLES DIAMETER 8mm TROUS DE PERCAGE POUR LA HOTTE DIAM 8mm FUROS DE FIXA AO DE 8 mm DE DIAMETRO OTWORY DO MOCOWANIA OKAPU 8 mm MIN 650 PLEASE READ INSTRUCTIONS CAREFULLY BEFORE COMMENC ING INSTALLATION CHECK THAT THE ELECTRICAL SUPPLY DATA QUOTED ON THE RATING PLATE OF THE APPLIANCE AGR
2. 15 6 73 46881 Thailand Bangkok TEKA THAILAND CO LTD 66 2 5164954 2 9021484 The Netherlands Zoetermeer TEKA B V 31 79 345 15 89 79 3345 15 84 Turkey Istanbul TEKA TEKNIK MUTFAK A S 90 212 274 61 04 212 274 56 86 U K Abingdon TEKA PRODUCTS UK LTD 44 1235 86 19 16 1235 83 51 07 U S A Tampa TEKA USA INC 1 800 419 9344 813 228 8604 Venezuela Caracas TEKA ANDINA S A 58 212 291 28 21 212 291 28 25 KUCHENTECHNIK Teka Kuchentechnik GmbH Sechsheldener Str 122 35708 Haiger Germany Tel 49 2771 8141 0 Fax 49 2771 8141 10 http www teka net Teka Industria S A Cajo 17 39011 Santander Spain Tel 34 942 35 50 50 Fax 34 942 34 76 94 http www teka net JKP 06 03
3. EES WITH THAT OF YOUR SUPPLY SEE NOTE SAFETY REQUIREMENTS These instructions are designed to tell you of the various technical details of your cooker hood and to make you familiar with its use Since these instructions cover more than one type of the hood within the same series it may be that reference is made to components that do not form part of the hood that you are installing The hood may be used as an exhaust or filter hood If evacuation is available exhaust duct or air flue we recommend using the hood in the exhaust version to discharge all the kitchen vapors and odors outdoors Suggestions for using the hood in exhaust position When an exhaust hood and a heat source requiring ambient air e g gas oil coal stoves etc are used atthe same time attention is required because the air necessary for combustion is exhausted from the room through the hood and this creates depression There is no such danger when the maximum depression in the room is 0 04mbar In this condition no exhaust gas from the heat source is piped To assure this condition make openings inthe room which cannot be closed doors windows etc are not sufficient and through which the air necessary for combustion can freely flow Note All the exhaust ductwork in the apartment or house should be studied In case of doubts get advise or authorization from the person or agency responsible for the building When using gas burners gas ovens etc as well as when us
4. igned for fixing to reinforced concrete masonry walls or hollow building blocks Installation without bracket 1 Set the distance between the cooker hob and the hood pict 4 2 Fix the two screws and the two upper plugs into the wall at the height previously chosen pict 5 3 Hang the hood to the wall checking that the screw pict 5 P correctly fits into the hole pict 5 R 4 In order to provide an exact installation the cooker hood in the rear of the body is supplied with two holes of 8 mm diameter where the two screws with plugs have to be inserted Insure that all parts are properly fixed and that it is impossible to touch moving parts Connection filtering exhaust 1 Inthe exhaust version link a 125 mm diameter air outlet chimney to the spigot pict 5 M This pipe is not supplied with the hood 2 Ifthe filtering connection pict 5 N is made of steel fix it onto the hood outlet by means of the three screws supplied Installation of the pipes valid for exhaust or filter version 1 Fix the bracket pict 5 0 with 2 plugs and screws pict 5 E in the required high for the pipe 2 Screw the short pipe pict 5 F with 2 screws on the bracket pict 5 G Putthe long pipe over the short one pict 5 1 by pulling a part the laterals of the pipe 4 Fix the long chimney from the outside pict 5 L by using two screws which must be inserted into the holes at the foot of the chimney pict 5 H Electric connect
5. ing the hood in the filter version these precautions are not necessary Note The efficiency of the exhaust hood decreases as the length of the ducts and number of elbows increase When using the exhaust version follow these rules Do not connect the exhaust hood to chimney flues and air ducts serving the room Before venting into exhaust flues and ducts no longer in use ask for the approval of the person or agency responsible for the building The evacuated air must not be let into a warm air duct For the evacuation of the exhausted air please note ufficial instructions Installation The hood must be mounted over the centre of the cooking area The minimum distances between the cooking area and the underpart of the hood are 650 mm Warning If the room contains a flued fuel burning appliance which is not of the balance flue type make sure these is an adequate air inlet to the room at all times so that fumes are not drawn down the flue N B The distances however are subject to the safety rules in effect in the various countries Before drilling the wall make sure that no pipes or cables will be damaged If there is no outer waste pipe for the exhaust version an air outlet with a diameter of 160 in case you use the spigot reduction pict 5 C you need an exhaust outlet of 130mm Attention Take attention that the wall will support the weight of the cookerhood about 30 Kg The screws supplied with this rangehood are des
6. ion Make sure the supply voltage ratings correspond with those stated on the appliance dataplate Attention if the appliance is not provided with a plug or cannot be easily connected to a wall socket then the electrical circuit must incorporate a circuit breaker having at least a 3 mm separation between contacts If the appliance is provided with a supply cord and plug the appliances must be positioned so that the plug is accessible Introduction 3 Attention the electrical supply cable must be connected as follow Green Yellow ground Blue neutral Brown line Important the hood manufacturer will not be responsible for any damage or loss caused by failure to observe these instructions Important a damaged power supply cord must be replaced by the service Operating instructions The cooker hood should be switched on either before or at the same as cooking or frying commences The grease and carbon filters are more effective if the fan is not switched off immediately after cooking or frying is completed but only after a period of some 20 30 minutes Before using the cooker hood please ensure that all plastic films like on metal grease filter an stainless steel ducting are removed User instructions Working instruction of the cooker hood Mechanical Switches Pict 3 slide or pushbutton 1 Speed Switch 2 Light Switch Lamp Replacement To changes a incandescent bulbs please work from outside of the hood means to p
7. l cavity unless designed for the pur pose Note instructions for cleaning fan as note 4 on MAINTE NANCE Moreover it is important to clean regularly each filter of the hood or replace it N B THE RANGEHOOD IS DESIGNED FOR IN DOOR USE ONLY UNDER NO CIRCUMSTANCES SHOULD THIS UNIT BE INSTALLED IN OUTDOOR CONDITION OR OVER A BAR BECUE TEKA GROUP NS SO ram COUNTRY CITY COMPANY cc PHONE FAX Austria Wien KUPPERSBUSCH GES M B H 43 1 86680 0 1 86680 72 Belgium Zellik B V B A K PPERSBUSCH S PR L 32 2466 8740 2466 7687 Chile Santiago de Chile TEKA CHILE S A 56 2 273 19 45 2 2173 10 88 China Shanghai TEKA CHINA LTD 86 21 6236 2375 21 6236 2379 Czech Republic Brno TEKA CZ S R O 42 05 4921 0478 05 4921 0479 France Paris TEKA FRANCE S A R L 33 1 5836 4830 1 5836 4831 Greece Athens TEKA HELLAS A E 30 210 9760283 210 9 12725 Hungary Budapest TEKA HUNGARY KFT 36 1 354 21 10 1 354 21 15 Indonesia Jakarta P T TEKA BUANA 62 21 39052 74 21 39052 79 Malaysia Kuala Lumpur TEKA K CHENTECHNIK MALAYSIA SDN BHD 60 3 762 01 600 3 762 01 626 Mexico D F TEKA MEXICANA S A DE C V 52 555 762 04 90 555 762 05 17 Poland Pruszk w TEKA POLSKA SP ZO O 48 22 738 32 80 22 738 32 89 Portugal llhavo TEKA PORTUGUESA LTDA 351 234 32 95 00 234 32 54 57 Russia Moscow TEKA RUS LLC 7 095 737 4689 095 737 4690 Singapore TEKA SINGAPORE PTE LTD 65 6 73 424
8. the fan and air ducts to prevent build up of flammable fat deposits The carbon filter When acarbon filter is fitted the air that is sucked in is additionally cleaned by the active carbon particles within the filter This filter cannot be cleaned and so needs to be replaced from time to time approximately every six months depending on how frequently the hood is use Replacing the active carbon filter only for recirculation hoods The filter can be easily removed itis sufficient to rotate it anticlockwise pict 2 Grease filter This absorbs vapour suspended grease particles and protects the kitchen and furniture from greasy residues The filter should be washed every 10 to 15 days in normal operating conditions Dip the filter into a de greaser solution or putitin the dish washer Make sure not to damage the filter which is made of several layers of thin alloy by hitting or crushing it The aluminium filter will may change colour that will have no influence of the efficiency of the filter may it will improve it Replacing or cleaning the filters To remove the aluminium grease filter pict 1 grab the opening tongue at the filter pull it in your direction and move the filter downwards To reinstall it operate reversed Safety Requirements Exhaust air must not be discharged into any chimney or flue which may carry combustion products from other sources In addition exhaust air must not be discharged into a wal
9. ull off the lamp diffuser Never use lamps with a wattage higher than the one shown on the label inside the hood Safety rules Do not do any flamb cooking underneath the hood When frying never leave the pan alone because the cooking oil could flare up Clean all the surfaces frequently to avoid danger of fire This can be done with a cloth or and with a brush drenched with denatured alcohol or with any other similar It is also important to remove and clean or substitute frequently the filter installed inthe hood This appliance is not intended for use by small children orinfirm persons without supervision Young children should be supervised to ensure that they do not play with the appliance Maintenance NOTE Prior to any maintenance switch off and disconnect from electrical supply 1 Under normal cooking conditions the grease filter should be cleaned every 10 15 days in hot water to which a suitable detergent has been added For reasons of efficiency and safety regular cleaning is advised The grease filter may be subject to a small amount of shrinkage initially 2 The outer casing of the Cooker Hood should be cleaned with a damp cloth 3 The effective life of the carbon filter will naturally depend on the frequency and type of cooking fumes to which it is subject As general guide we suggest that a replacement is fitted at least every 12 months 4 Once a year more frequently with heavy usage call a serviceman to clean