1.    DOUT menu     amp     AMP menu    The DOUT menu offers two options  Option    1    will force the system to output Left  and Right channel signals at digital output 1  and Left SUB and Right SUB channel  signals at digital output 2  Option    2    will output Left main channel and Left  subwoofer at digital output 1 and Right main channel and Right subwoofer at digital  output 2        This menu is designed to support TACT digital amplifiers  In many stereo systems  digital amplifiers are used to power both main channels and subwoofers  You would  use option    1    if both Left and Right channel are connected to the same amplifier   and both Left SUB and Right SUB channel are connected to the same amplifier  In  the case where one main channel and one SUB are connected to the same  amplifier you need to select option    2     To select one of the options  use the    LEFT     or    RIGHT    navigational buttons to position the cursor over the desired option and  press the    ENTER     bution to select it     NOTE  This menu has no affect on the analog outputs     The AMP menu is designed to allow the RCS 2 2X to interface with the TacT M2150  or  2150 digital amplifiers  The RCS 2 2X can control multiple digital amplifiers   This setting should be ENABLED only if you have a Tact digital amplifier  attached to the RCS 2 2X        2 1    For example  one amplifier can be used for main left and right channel and second  one can be used for the left and right subwoofer channel
2.    Owner   s Manual    RCS 2 2X    Preamplifier   Room Correction System       Blank Page    WARNING    TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK  DO  NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE     CAUTION    RISK OF ELECTRIC  SHOCK DO NOT OPEN    CAUTION  TO REDUCE THE RISK OF ELECTRICAL SHOCK   DO NOT REMOVE COVER  NO USER SERVICEABLE PARTS  INSIDE  REFER SERVICING TO QUALIFIED PERSONNEL        The exclamation point within an equilateral triangle is intended to alert  the user to the presence of important operating and maintenance  ser   vicing  instructions in the literature accompanying the product        The lightning with arrowhead symbol within an equilateral triangle is  intended to alert the user to the presence of    Dangerous Voltage     within the product s enclosure that maybe of sufficient magnitude to  constitute a risk of electrical shock to a person        Tact Audio 3    Important Safety    Instructions    Cleaning and  Maintenance       Note    symbol    4 Tact Audio     amp     AF NS     gt     11      b  a    Read these instructions entirely before installing or operating this equipment   Keep these instructions    Heed all warnings    Do not use this equipment near water or allow it to become wet    Do not block any ventilation openings  Install in accordance with the  manufacturer s instructions    Do not install near any heat sources such as radiators  heat registers  stoves  or  other appliances  including amplifiers  that produce heat   doing s
3.   PRESET menu option  This option allows for EQ preset  selection  The         character indicates the current preset  To  select a new preset highlight the PRESET option and by use  the    LEFT    and    RIGHT    buttons to scroll through available  presets  When the desired preset is displayed press the     ENTER     button to select it     4   LOCK menu option  This option is used to lock the current  parametric EQ preset  When set to YES the parametric EQ  preset can not be changed  To change the LOCK seiting high  light the current LOCK selection press the    ENTER    button to  toggle between the YES and NO selections     5   Active Preset display  This displays the preset that is  currently loaded into the system  This is not a selectable  menu option     Front Panel Displa    Parametric EQ This is an example of the linked parametric EQ filter table  Its display allows for ad   Table   Linked justment of all filter parameters  Level  center frequency and Q factor  The filter pa   rameters will be applied globally to both the left and right channels   1       1   Indicates that this table is for linked filters   2   Current parametric EQ preset   3   Filter order  For more filters scroll down the list     To change a parameter first highlight it and press the    ENTER    button  Then use  the    LEFT    and    RIGHT    navigational buttons change the parameter value     Parametric EQ This is an example of the left channel parametric EQ filter table  Its display allows  
4.  3             Active correction preset indicator     Tact Audio 29    Front Panel Displa    Parametric EQ menu    30 Tact Audio     amp     The Parametric EQ menu is used to apply up to twelve bands of parametric equal   ization for the left and right channels  The EQ processing can be applied in two dif   ferent ways  Both the left and right channels can be linked together to apply pro   cessing globally  or both the left and right channels can be processed indepen   dently for unique settings for each channel     Note  An EQ preset must be enabled from the main screen for the PAR EQ and  TONE menus to be active  If the EQ preset is set to    BP    the PAR EQ and  TONE controls are disabled        1   TABLE menu option  To enter the TABLE menu screen  highlight and select either the    LEFT  amp  RIGHT        LEFT      or    RIGHT    selections and then press the    ENTER    button  The  available selection will be determined by the setting of the LINK  option explained below     2   LINK menu option  This option determines if the left and right  channels are linked to the same EQ filters  If    NO    is selected  the channels are not linked and each channel has a separate  set of EQ filters  If    YES    is selected the channels are linked  and there will be only one set of filters used for both the left  and right channels  To change the LINK setting highlight the  current LINK selection and press the    ENTER     button to toggle  between the YES and NO selections     3 
5.  Audio 35    Quick Setup    STEP      Select the speaker configuration setting that you have set for the RCS 2 2x  Operating Mode  This setting is found in the  MODE  menu on the front panel of the    RCS 2 2 X   aj  Taci 22    Operating Mode i  E Shanes 22 Shanes 2 1 C Shane 20      Deke thit gpho i arii Deke thee codon i ii jesd tee ion i pour  cher oonan cd hen me paet oonan od e re piem coreests of ony h  Subs ete Sule   Select     2 2 operating mode   If your system uses two main loudspeakers and two  subwoofers     2 1 operating mode   If your system uses two main loudspeakers and one  subwoofer     2 0 operating mode   If your system uses only two main loudspeakers     You will then need to set the Loudspeaker Crossover Frequency or Loudspeaker  Lower Cutoff frequency  Your Operating Mode selection will determine what  parameters will need to be set  Your subwoofer and main loudspeaker frequency  response will determine the settings needed for these parameters  Please refer to  your main loudspeaker and  or subwoofer manual for this information      Loudspesker cross over irequency  Fiesa paleni the mam oub maera fequency acd  gaban lose  coi hegae  Thee peeled aoe  genbe  by yoa kulges e maisu             If you have selected 2 2 or the 2 1 operating mode you will need to set the     Loudspeaker crossover frequency  this sets the lowest frequency that will be  sent to your loudspeakers       Subwoofer lower cutoff frequency  this is the lowest frequency that your  sub
6.  are 24 bits at 44 1  48  88  96 or 192 kHz sampling rates  The output  sampling rate is set in the    DOUT    menu   TosLink does not support 192kHz     The sub output is for your subwoofer s  and can be configured for either mono or  stereo  Use the    MODE    menu to set the appropriate output mode 2 0  2 1  or 2 2   Connect one of these outputs to a TacT digital amplifier or external DA converter        Optional modules The RCS 2 2X is designed to accommodate virtually any input and output needed  without adding extra cost for features certain users might not use  There are therefore  3 optional modules that can be installed      ADC converter module for analog inputs such as a Tuner   Cassette deck  VCR etc      DAC converter module for main channels  for example  when the RCS 2 2X is used with traditional analog  amplifiers     DAC converter module for subwoofer s   for example when  the RCS 2 2X is used with analog self powered  subwoofer s     These modules are based on the latest 24 bits 1 92kHz state of the art technology  and offer performance far beyond that of most stand alone converters  Due to the  modular design of the RCS 2 2X  these modules can be added any time or exchanged  if upgrades should become available     Tact Audio 11    RCS 2 2X Connections    Analog input The RCS 2 2X has 4 stereo analog inputs when the optional ADC module is installed    optional ADC module       three analog stereo single ended  RCA     one analog stereo balanced  XLR        N
7.  communication port once  The next time  you run the Tact 2 2X software it will remember your settings     Before You Begin    b       Getting Started    Quick Setup    The Tact 2 2X Quick Setup wizard is designed to help both the first time and  experienced user perform complete room correction and create nine correction  presets quickly and easily  To run the Quick Setup successfully you will need to  know your speaker configuration  your loudspeakers lower cut off frequency  and  the type of amplifier s  that you have connected  This information will allow the  Quick Setup to automate the room correction process for you so that you can  begin enjoying the benefits of room correction immediately  For a detailed  explanation of all of the software features and instruction for performing room  correction manually please see the online help available in the software     1   Connect the RS 232    Input    jack on the back of the RCS 2 2 X to your  computers serial port using the supplied cables and adapters     NOTE  These instructions assume that you have already established  communication between the RCS 2 2X and the Room Correction Software  on your computer  See page 32     2   If you have one or more TacT M2150 S2150 digital amplifiers connect  them to the RCS 2 2X  Please make sure that a unique address has  been set for each device  For further instructions please refer to your  M2150 S2150 owner   s manual     3   Make sure that the RCS 2 2 X is powered off from the rea
8.  general menu option     Input sampling frequency indicator   This displays the sampling frequency of the currently selected digital input  The RCS  2 2X will automatically detect input signal presence and display its sampling  frequency     RCS 2 2X operating mode  This displays the systems operating mode  The operating mode can be modified  from the    MODE    general menu option        Saving Menu Custom settings that are made to any of the menu selections can be saved by  Settings placing the RCS 2 2X into standby mode  If you make changes to any of the menu  items and turn the unit off before placing the unit into standby mode all settings will be    lost  To place the RCS 2 2X into standby mode press STANDBY button found on the  front panel of the unit or the red    STANDBY    button on the remote control     Tact Audio 19    Front Panel Displa    MAIN menu The main menu screen lists all of the RCS 2 2X general menus  To highlight a  menu option 1  use the navigational buttons  To enter a highlighted option press the     ENTER     button        MODE menu The RCS 2 2X can be set to one of four operating modes  To highlight an option use  the navigational buttons  To enter a highlighted option press the    ENTER     button          STEREO 2 2  This mode produces 4 output signals  Left  Right   Left SUB  and Right SUB       STEREO 2 1  This mode produces 3 output signals  Left  Right  and one SUB signal  In this mode the SUB signal is mono  and is output to both the Left S
9.  highlight it using the navigation  buttons and then press the    ENTER     button to select it     2   CORR   This option allows for correction selection  When this  option is highlighted use the    LEFT    and    RIGHT    navigation  buttons to scroll through all possible correction presets  To  select the displayed preset press the    ENTER     button  Note  that the         character indicates the currently selected  correction preset     3   LOCK   This option allows you to lock the correction preset  setting  When this option is highlighted use the    ENTER     button to toggle between the    YES    and    NO    options  When     YES    is displayed the selected room correction preset is  locked and can not be changed by either front panel or remote  control     4   Active Corr    This displays the currently selected room  correction preset number     4   Name   This displays the currently selected room correction  symbolic name     Tact Audio 27    Front Panel Displa    LEVELS menu    o   amp     DELAYS menu    28 Tact Audio    The level menu allows for control of the system channel balancing  You can adjust  the system balance by changing the attenuation on any of the four output signals   To highlight an option use the    UP    and    DOWN     navigational buttons  To change  the current value use the    LEFT    and    RIGHT    buttons        1   Currently selected correction option   2   Individual channel level settings     NOTE  The RCS 2 2X provides a unique set 
10.  start the Quick Setup  automation     Diath Setup   STEP F    You have made the following selections        Tatts opaan mde  iA   Tact  2N qessover hegouency 200  Loud  paake lpia culoll heguencp  3   Humber of measurements per channel 25    Three Mi S 2150 ae commected Teas bo main oum amd ome bo subwoole  ouik  Du  1 AMP 7 dence addeese   2   Out HI AMP 2 dewoe addeess a 3   Gul HZ AMP device addissy   4       Check to see    your selections listed above are accurate for  your system setup  Use the  Go Back  button to fie any  erroneous selections  After you press the    Fmush  button  below  you wil have 15 seconds to eave the room  and close  the door  before the measurement process begs  After the  measurement i  completed  your RS mne comecton presets  wil be programmed  Your system wall then be ready for  mmediate Letenng and evaluation of the mne preset correction  curves     The measurement process can either use a kava faster or higher move accurate   number of lect pulses lo masira your soon  Select bom the lolloveng     Number of measurements per channel  25            If the settings listed are not correct select the    Back    button to go back and  make the appropriate changes and return to the finish screen when you are ready  to start the Quick Setup       If the settings listed are correct select the    Finish    button  This will start the  Quick Setup measurement and programing automation  When the automated  process is completed the    Quick Setup Comple
11.  the  unlikely event that the unit needs servicing  If this unit is shipped without the original  packing  damage could occur and void the warranty     Accessories You should find the following items in the accessory kit       one AC mains cord     RJ11 data cable     RJ11 to RS232 adapter     15    RS232 cable     CD ROM with RCS software    Measurement microphone     remote control     2 AAA batteries     this manual    Operating voltage The RCS 2 2X is designed with an automatic switching power supply  It will operate  on 65 265 volts at 50 60hz  No external settings are required     The RCS 2 2X has three operating modes     OFF AC mains power is cut off  either via the rear  panel mains switch  or by unplugging it from the  wall outlet     STANDBY The unitis powered but all outputs are muted and the  display is off  The unit uses very little current and    is    idling    or    sleeping    Use the remote or front panel     STANDBY    button to toggle between ON and STANDBY       ON Everything is powered and ready to go     Tact Audio 7    Room Correction  System    Separate Subwoofer  Control    Flexible DSP   s    8 Tact Audio    Introduction    Congratulations on your purchase of your RCS 2 2X  You have now acquired the most  advanced stereo Preamplifier   Room Correction System ever developed     The RCS 2 2X has four times the processing power of the famous TacT RCS 2 0 and  even better AD and DAconversion  This now combined with new features and a more  user friendl
12.  will scroll sequentially  allowing the selection one of the 5  digital inputs     3  ANALOG  The ANALOG button will scroll sequentially  allowing the selection one of the4  analog inputs     4  CORRECTION block   The CORRECTION block consists of 10 buttons  The buttons are numbered from 1  to 9 and one BYPASS  Pressing the BYPASS button will place room correction  into bypass mode     no correction  Pressing any of the remaining nine buttons will  engage the corresponding room correction preset     5   MENU  The MENU button will switch the front panel display from the status screen to the  main menu screen     6  VIDEO  The VIDEO button is inactive with this unit     7  UP  The UP navigational button is used to select menu options and or change their  values     8  DOWN  The DOWN navigational button is used to select menu options and or change their  values     9  LEFT  The LEFT navigational button is used to select menu options and or change their  values     10  RIGHT  The RIGHT navigational button is used to select menu options and or change their  values     11  ENTER  The ENTER button will select the menu option currently marked by the blinking  cursor or enter an edited parameter     12  VOLUME Block   The VOLUME block consists of three buttons    The    MUTE    button will mute un mute all enabled channels   The    UP    button will increase the master volume level   The    DOWN     button will decrease the master volume level     Tact Audio 17    18 Tact Audio    Mai
13. Corporation     The information contained in this document is subject to change without  notice     Registration    IMPORTANT  Please record your serial number here for future reference  You will need this for  future upgrades or should you ever require service on your RCS 2 2X Preamplifier     RCS 2 2X serial number     Optional modules installed        DAC 1 analog output   main channels  DAC 2 analog output   subwoofers  ADC analog input    Tact Audio 5    Table of contents    Safety instructions  Acknowledgments Registration  Unpacking the RCS 2 2X  Introduction   Connecting the RCS 2 2X   Front Panel Controls   Remote Control    Front Panel Display  Main screen  Saving Menu Settings  MAIN menu  MODE menu  ADC menu  DOUT FS menu  POL menu  TEST menu  DISPLAY menu  COMM menu  CRO menu  OPTIONS menu  DOUT menu  AMP menu  CORR menu  LEVELS menu  DELAYS  NAME menu  PAREQ menu  TONE menu    TacT 2 2X Room Correction Software  System Requirements  Software Installation  Microphone Installation  Connect your RCS 2 2X to  your Computer    Quick Setup    Update the RCS 2 2X Firmware    6 Tact Audio    Unpacking the RCS 2 2X    Carefully remove the RCS 2 2X and accessory kit from the carton and visually check  for shipping damage  Contact both the shipper and TacT Audio immediately if the unit  shows any sign of damage from rough handling  All Tac T Audio equipment is carefully  inspected before leaving our factory     KEEP SHIPPING CARTON AND PACKING MATERIALS for future use or in
14. OTE  A D conversion is always performed at 24 bits 192 kHz     AN NOTE  The optional ADC module is required for analog inputs        Analog output The RCS 2 2X has 2 stereo analog outputs for main channels when the optional DAC    main channels  MAIN module is installed    optional DAC module       one analog stereo single ended  RCA     one analog stereo balanced  XLR     AN NOTE  The optional DAC module is required for analog outputs        12 Tact Audio    RCS 2 2X Connections    Analog output The RCS 2 2X has 2 analog outputs for subwoofer s  when the optional DAC SUB    subwoofer s  module is installed    optional DAC module       one analog stereo single ended  RCA     one analog stereo balanced  XLR     AN NOTE  The optional DAC module is required for analog outputs        Microphone input Connect the supplied measurement microphone to the    Mic Input    connector when  taking a room measurement for room correction     CAUTION  To avoid damage through static discharge  we strongly recommend  to turn off the RCS 2 2X at the rear panel mains switch before connecting the  microphone          Tact Audio 13    RCS 2 2X Connections    RS 232 interface The RCS 2 2X has two RS232 interface ports   ports    INPUT   AUX    Use the    INPUT    port for communication with your Personal Computer     Use the    AUX    port to connect to TacT digital amplifiers  or to daisy chain with  multiple RS232 components              AC mains input Connect the RCS 2 2X to the AC mains wall so
15. T be removed     You now need to install the new TacT 2 2X RCS software on your computer       Double click on the    Tact 2 2X vx x exe       file that you have downloaded or is  found on the root of your CD and follow the installation instructions     Program the new firmware for the RCS 2 2 X     1   Connect the PC to the RCS2 2X using the RS232 cable  Please refer tothe  RCS 2 2X RS232 section of the user   s manual or the RS232 Connection document  for help     CAUTION  The RCS 2 2 X should be the only device connected to the RS232  cable during system reprogramming  Please disconnect any TacT digital  amplifiers that may be daisy chained to the RCS 2 2 X     2   Start the TacT 2 2X RCS software on your computer  3   Use the    Communication    option in the Tact 2 0 S room correction software to  make sure that the RCS 2 2 X and your computer are communicating  Please refer    to the RCS 2 2X RS232 section of the user   s manual or the RS232  Connection document for help     4  Turn the RCS 2 2 X OFF from the rear panel mains switch     Update the Tact 2 2 X Firmware    5   Press and hold the    DIGITAL    and    ANALOG    buttons on the front  panel of the RCS 2 2 X simultaneously while you turn the unit back ON  from the rear panel mains switch  Hold the buttons until the display  shows the    PROGRAMMING MODE     screen        6   From the TacT 2 2 X RCS software main screen  click on the    Add Ins    and then  select the    Standard    option  You should now see th
16. Table   Not Linked for adjustment of all filter parameters  Level  center frequency and bandwidth and  they will be applied independently to the left channel  There is a similar table for the  right channel  You can enter the right channel table from the previous menu        1   Indicates left or right channel filter table   2   Current parametric EQ preset   3   Filter order  For more filters scroll down the list     To change a parameter first highlight it and press the    ENTER    button  Then use  the    LEFT    and    RIGHT    navigational buttons change the parameter value     Tact Audio 31    Front Panel Displa    TONE menu    The tone menu allows for easy and very detailed system tonal control  Use the  navigation buttons to highlight an option  To select the highlighted option press the     ENTER    button  To modify the selected option use the    UP    and    DOWN    naviga   tional buttons  To deselect the selected option press the    ENTER     button again        3    1   Level control is used to set the low  mid and high frequency  filter attenuation  Filter level is given in dB and can be changed  in increments of 0 1 dB  Maximum filter level is 12 dB and  the minimum filter level is  12 0 dB     2   Frequency Control is used to set the cutoff frequency for the  low and high frequency filters and to set the center frequency  for mid  bandpass  filter   3   Q  Octave  control sets the filter bandwidth for the mid filter   B  Note  An EQ preset must be enabled fro
17. UB and Right SUB outputs       STEREO 2 0  This mode produces 2 output signals  This is standard two  channel stereo mode  In this mode there is no signal at the  subwoofer outputs       Mono  This option can be set to ON or OFF  When set to ON the  system will output the same signal for both the Left and Right    channels     20 Tact Audio    ADC menu   optional ADC module     o    DOUT FS menu    Front Panel Menu    The RCS 2 2X can be equipped with a state of the art Analog to Digital Converter   ADC module optional    To further enhance the converters performance  the system  offers two selectable gain values for the ADC input stage  These values can be  assigned to each input independently     NOTE  The optional ADC module is required for analog inputs        To select an option use the    UP    and    DOWN    navigation buttons and to change its  value press the    ENTER    button to toggle between the  6dB and 0 dB selections     The RCS 2 2X is equipped with a sample rate converter on each digital output   Each output can independently be set to 44 1  48  88  96 and 192 KHz sampling  frequencies        To set the sampling frequency for digital output 1  use the    LEFT    or    RIGHT     navigational buttons to highlight the desired option  on line 1  and then press the     ENTER    button to make the selection  The new sampling frequency will be  displayed in block  3      To set the sampling frequency for digital output 2  use the    LEFT    or    RIGHT     navigati
18. cket    amp  mains switch Use the mains switch to turn power ON or OFF     A CAUTION  Use the supplied IEC mains cable  or a 3 prong grounded cable only           14 Tact Audio    Front panel controls    The front panel controls on the RCS 2 2X will allow you to access and control all  menu settings     Digital Input Selector Input Display Master Volume Menu       Standby Mute Volume Level Navigation Enter    Analog Input Selector    Standby Use the    STANDBY    button to toggle between Standby mode and ON   The display will indicate Standby mode by displaying a small green light in the left  side of the display  When the unit is placed in Standby mode all user settings are  saved     Master volume The master volume is controlled by turning the    TacT wheel     The green digits on the  left side will change as you turn the wheel   this is your master volume level indicator    The wheel sensitivity  max  volume etc  can be set in the    OPTIONS    menu      Mute Use the    MUTE    button to mute or un mute during playback  The volume level indica   tor will switch to          in Mute mode  You can still adjust the master volume while the  unit is in Mute mode   the volume level indicator will briefly indicate the level  then  switch back to the          mute indicator    Digital Press the    DIGITAL    button to select the digital input  This is a toggle switch  and by  input selector pressing it multiple times it will toggle through all of the five digital inputs  The se   
19. e Add Ins window         gt   Pamei Fil      lgl x     Tack 2 System Paogam           f a a   la ee fad Cee  Tacdt 2 2 opershng wren Bef  Pimentel ag ee we  Dory BOOT wou hired cad   F  rief   Fii kb    LP ee ihe       7   Select the    Program    button and follow the prompts by answering all  questions  You will need to be able to answer    Yes    to all questions to   start the programming  The RCS 2 2 X will turn OFF and ON and then return to  normal operation     Tact Audio 41    Update the Tact 2 2 X Firmware    Step IV  After updating the firmware the System Files now need to be reprogrammed   Reprogram the  System Files              Program Tact 2 2 S       jm j suaj   wI r   wjr r  el Mal T E  ej mj r r  Ami Tr  r   me  e r    mir r   mj TF r       w E   a  O r  Croese          05      Fraas MyProjct    1   From the TacT 2 2 X RCS software main screen  click on the    Program TacT   2 2 X    button  You should now see the programming window     2   Press and hold the    Control    key on your computer keyboard and then press  the    S    key simultaneously  This should display the System Option  1  in the  bottom center of the programming window     3   Left click your mouse in the square next to System to select it with a check  mark     4   Press the    Program    button and follow the prompts by answering all  questions  You will need to be able to answer    Yes    to all questions to start the  system file reprogramming  The RCS 2 2 X will return to normal operat
20. e name should match the  serial number of the mic that came with your RCS 2 2X    7   The software installation will confirm with the    Mic installation complete     message    8   After you have installed your mic the mic serial number should be displayed in  the    Microphone    section at the top of the main page  If it is not please close  the software and restart it to register your mic file with the software     Tact Audio 33    Connect your  RCS 2 2X to your    34 Tact Audio    Computer    o    b    AN    Tact 2 2X Room Correction Software    Your RCS 2 2X must be connected to your computers serial port in order for it to  communicate with your computer and to run the Quick Setup and correction pro   cess  Please follow the steps below to connect your RCS 2 2 X to your computer     1   Connect the RS 232    Input    jack on the back of the RCS 2 2X to your  computers serial port using the supplied cables and adapters  Your  computer must have a standard RS 2382 serial port with a DB 9 connector     NOTE  If you have any Tact digital amplifiers please disconnect their RS232 con   nection at this time     2   Turn on your RCS 2 2X     3   Turn on your computer and start the Tact 2 2X Correction System  Software     NOTE  You may receive a communication error message  Please close the  message window and proceed to the next step     4   Select the    Communication    button on the main software screen to open  the communication window     5   Under the Operating Mode sel
21. ect    Connect        6   Under the COM Port section select    COM1     If you receive an    invalid  port number    message please try selecting each of the port selections until  you do not receive this message  If you receive this message on all COM ports  you may not have a COM port installed on your computer  Please refer to your  computer manufactures documentation for help to install a COM port     7   To verify that RCS 2 2X is properly connected to the host computer click  on the    Start    button to perform the communication test  If everything is  functioning properly you should see the results below  Press the    Stop     button after about 15 seconds to stop the test     Rx Buf should display    0      Count should have counted in increments of 100   Err Count should be    0        If the results are as above select the    Close    button to close the  communication window  Your RCS 2 2X is now connected to your computer     If the results are not as above please go back to step number 6 and select  another COM port  Then repeat step 7     NOTE  If you are still are not passing the communication test you may not have a  COM port installed on your computer or you may have another device such as a  modem or hand held PC that may be sharing the COM port on your computer  If  you have a Tact amplifier attached it may be set to the same address  The RCS re   quires a valid COM port that is not being used by any other devices     NOTE  You will only have to select the
22. igational buttons to  highlight the desired baud rate and then press the    ENTER    button to select it  The  new baud rate will be displayed on the bottom of the screen     To change the system device address highlight the    Address    option and then us   ing the    LEFT    and    RIGHT    navigational buttons select the desired system ad   dress  The RCS 2 2X is shipped with the default address set at 1     NOTE  If you change the device address make sure that you select the ap   propriate device address in the RCS 2 2X Room Correction software     The crossover menu offers five crossover selections options for use in bypass mode  only  Crossovers in correction mode are implemented into the correction filter via  the RCS software  To highlight an option use the    UP    and    DOWN    navigational  buttons  To make a selection press the    ENTER    button  The selected option will be  displayed on the top of the screen 1      1       When an option is selected the system will load the crossover filter and resume to  normal operation  Crossover filters are user programmable from the Crossover  screen in the Room Correction Software     Crossover names are also user programmable from the Crossover screen in the  RCS software  For crossover names you should choose symbolic names that  somehow relate to the crossover filter characteristics     OPTIONS menu     amp     Front Panel Displa    The options menu allows for control of the systems maximum signal level  signal  detec
23. ion mode  when finished     42 Tact Audio    Step V   Restoring the Default  RCS2 2X Settings    g    RCS 2 2X  update complete    This step is optional and is only required if you would like to reset all  internal settings in the unit to their factory defaults  If you proceed  you will erase your custom user settings     Restore the default settings for the new firmware installed on the RCS 2 2 X     1   From the TacT 2 2 X RCS software main screen  click on the    Options    menu  selection at the top of the screen and then select the    Default Settings    option   You should now see the Default Settings window        TOME  wif HEH   m E  S ae    i y Dee   Tr  Eu         2   Select the    Default    button and the default parameters for the RCS 2 2 X will be  loaded into the RCS 2 2X  The RCS 2 2X will turn OFF and then ON and return to  normal operation when finnished     NOTE  If you have TacT digital amplifiers attached to the RCS 2 2 X you  must set the    AMP    front panel general menu to    DISABLED     The default  settings will not be programed if these parameters are set to    ENABLED        You have now completed updating your RCS 2 2X and it is ready for normal  operation     Tact Audio 43    TacT Audio  Inc     201 Gates Road Unit G  Little Ferry     New Jersey 07643  USA  Phone   1 201 440 9300     Fax   1 201 440 5580     Email  info tactaudio com    www tactaudio com    
24. lected input will be displayed in the input display portion of the display     Analog Press the    ANALOG    button to select the analog input  This is a toggle switch  and  input selector by pressing it multiple times it will toggle through all of the four analog inputs  The  selected input will be displayed in the input display portion of the display      amp  NOTE  Please note that the optional ADC module is required for analog in     puts   Menu Press the    MENU    button to access the front panel menu system   Navigation Enter Use the navigational buttons to navigate the options and select with the middle    En   ter    button    LN NOTE  The remote and front panel controls are disabled whenever a Per   sonal Computer is connected and the Room Correction or ParEQ software is    running  To enable the remote and front panel controls press the    DIGITAL     and    ANALOG     input selector simultaneously     Tact Audio 15    Remote Control    The remote control is used to access the front panel display controls and menus     1 2   3  4   5  7 6  9 10  11 g  12       16 Tact Audio    Remote Control    1   STANDBY   The STANDBY button will turn the RCS 2 2X on or it will place it into standby  mode  When in stand by mode  the unit is placed into a low power    idling    state   The standby button is also used to save changes that were made in the menu  parameters  By placing the unit into standby mode the current menu settings are  saved     2   DIGITAL  The DIGITAL button
25. m the main screen for the PAR EQ    and TONE menus to be active  If the EQ preset is set to    BP    the PAR EQ  and TONE controls are disabled     32 Tact Audio    System requirements    Software Installation    Start The Room  Correction software    Microphone  Installation    TacT 2 2X Room Correction Software    The RCS 2 2X employs some of the most advanced audio software ever developed   In order to use the proprietary TacT Room Correction System  you will have to  install the supplied software on your computer  Complete instructions for using the  room correction software can be found in the online help available in the software   To make the room correction process easier for the first time user there is a Quick  Setup feature that is described later in this manual     Your computer system must meet the following requirements      An IBM compatible PC with Pentium 100 MHz  64 MB Ram  amp  100 MB  free hard disk space or better     Microsoft Windows 98  ME  2000 or XP     Operating system regional setting must be set to    English United States         Microsoft Windows compatible graphics card and monitor with screen  resolution 800x600 or better     CD ROM drive     Microsoft windows compatible 2  or 3  button mouse     Standard RS 232 serial port with DB 9 connectors    Follow the steps below to install the TACT 2 2X Room Correction Software     1   Start windows and insert the TacT software CD into your CD ROM drive   2   Double click on the    My Computer    icon 
26. n screen     amp     Front Panel Display    When the RCS 2 2X is powered on the main screen will be displayed   1 10 2       6 T 4 B    To move the cursor indicator  10  use the front panel or remote control navigation  buttons  To select an option press the    ENTER    button     1   Correction preset selection   2   EQ preset selection   3   Correction menu option   4   Parametric EQ menu option   5   Tone control menu option   6   Output sampling frequency indicator  7   Input sampling frequency indicator  8   RCS 2 2X operating mode   9   Master level in dB   10   Cursor indicator     Correction preset selection   To select one of the nine correction presets or bypass them use the    LEFT    or     RIGHT     navigation buttons to position the cursor over CR  1   Once the cursor is  positioned over CR  1  press the    ENTER     button  The system will then display a pull  down list containing all presets  Use the    UP    and    DOWN     navigation buttons to  point to the desired correction preset and then press the    ENTER     button  This action  will engage the selected preset and display the new selection in the CR box  1   Once  the cursor is positioned over CR  1  you can also select a correction preset by  pressing one of the ten buttons located in the block labeled    CORRECTION    on the  remote control     EQ preset selection   To select one of sixteen parametric EQ presets or bypass them use the    LEFT    or     RIGHT    navigation buttons to position the cur
27. n use the     LEFT    and    RIGHT    buttons to change the value          Timeout   This option is used to turn the front panel timer    ON     or    OFF     When this option is    ON    the front panel timer will  count the number of seconds specified by the Timeout in sec  option  and then turn the display OFF or dim it to a level  specified by OFF Brightness option       Timeout in sec   This option is used to set the number of  seconds that the display will remain on before turning off or  dimming after accessing an option on the front panel display   This parameter can be set to a value from 3 to 30 seconds  For  example if it is set to 15 seconds the front panel timer will count  15 seconds and then turn the display OFF or dim it to a level  specified by OFF Brightness option       ON Brightness   This option determines the front panel  brightness after the unit is powered on or an option on the front  panel display is accessed  This parameter can be set to any  value between 1 and MAX 16        OFF Brightness   This option determines the front panel    brightness after timeout has expired  This parameter can be set  to any value between OFF  0  and MAX 16      Tact Audio 23    Front Panel Displa    COMM menu    24 Tact Audio     amp     CRO menu    The communication menu allows for the RS232 baud rate selection and device  address assignment  By default the RCS 2 2X is set to baud rate of 57600        To change the system baud rate use the    UP    and    DOWN     nav
28. o may  damage the unit and present a fire hazard    Do not defeat the safety purpose of the polarized or grounding type plug  A  polarized plug has two blades with one wider than the other  If the provided plug  does not fit into your outlet  consult an electrician for replacement of the outlet to  one that is polarized  To protect against electrical shock  match the wide blade  of the polarized plug to the wide slot in the outlet and fully insert the plug   Protect the power cord from being walked on or pinched  particularly at plugs   convenience receptacles  and the point where they exit the equipment  Do not  use this unit with a damaged cord or plug    Only use attachments accessories specified by the manufacturer    Unplug this equipment during lightning storms or when unused for long periods of  time    Refer all servicing to qualified service personnel     Always unplug the unit from the electrical outlet before cleaning    Do not use abrasive cleaners  Simply wipe the exterior with a clean soft cloth  A  small amount of nonabrasive cleaner may be used on the cloth to remove  excessive dirt or fingerprints     The  gt note lt  symbol indicates information very useful or essential to daily    operation     Acknowledgments       2003 Tact Audio Corporation  All rights reserved    No part of this document may be reproduced or transmitted in any form or by any  means  electronic  mechanical  photocopying or other wise  without the prior  written consent of the Tact Audio 
29. of four levels  Left  Right  SUB  Left and SUB Right  for each room correction preset including bypass     NOTE  These levels are automatically adjusted for correction mode  We  strongly recommend that you only adjust the levels for Bypass mode   this  will allow you to match the level with correction mode     The delay menu allows for control of the systems time alignment  You can adjust  the system time alignment by changing the delay time on any of the four outputs   To highlight an option use the    UP    and    DOWN    navigational buttons and to  change the current value use the    LEFT    and    RIGHT    buttons        1   Currently selected correction option   2   Individual channel delay time settings     e       NAME menu    Front Panel Displa    NOTE  The RCS 2 2X provides a unique set of four delay times   Left  Right  SUB Left and SUB Right  for each room correction  preset including bypass     NOTE  System balancing is automatically implemented by the  room correction software  You would change these parameters  only if you needed additional adjustments     The name menu allows for selection of Room Correction presets based on their  symbolic names rather than based on their numbers  To highlight an option use the     UP    and    DOWN    navigational buttons to select a highlighted option and press the     ENTER    button        1   Available correction presets and their names  Keep  scrolling down for more presets    2   Currently selected correction preset   
30. omain  for completely seamless  integration surpassing even the best single box systems     With the RCS 2 2X  you can add subwoofers to an existing High End speaker system  for substantial sonic improvements  Preferably  the subwoofers should be placed in  the corners behind the main speakers  Corner placement of the subwoofers will yield  much higher efficiency with significantly reduced low frequency distortion  But more  importantly  the transfer of energy from the sub to the listening position will be much  more direct  resulting in vastly improved impulse response  The room correction  system will easily compensate for the frequency response variations of the subs  introduced by corner placement  It will delay the main speakers for perfect time  alignment to within 1 8 of an inch     The RCS 2 2X offers you the opportunity to add subwoofers to a system and improve  the transient response tremendously at the same  This contrasts sharply with the  normal result of adding subwoofers to a system  slow     undefined bass with lots of  frequency and time behavior problems  If the separate subwoofer outputs are not  used  then the RCS 2 2X will use all the processing power on the main speakers     Introduction    Modular design The internal layout of the RCS 2 2X is completely modular  All of the expensive com   ponents such as DSP   s  D A and A D converters are a plug in type and are placed on  a motherboard  This allows for easy and inexpensive future upgrades  Even the rea
31. on the desktop    3   Double click on the CD icon to launch the CD browser    4   Double click on    Tact 2 2X vx x exe    and follow the instructions     After the installation you will have the option to launch the RCS software  If you  would like to launch the program at this time when prompted  select    Launch  TacT RCS2 2X    and the software will start  You should now see the TacT 2 2X  Room Correction System main screen     To start the software go to the Windows    Start    menu  select    Programs    then     TacT 2 2 X    and click on the    TacT 2 2 X    icon  You should now see the TacT 2 2X  Room Correction System main screen     All TacT measurement microphones are individually calibrated to perform with the  highest accuracy and come with a unique calibration file  This file needs to be  installed before you perform the correction process  The microphone can be en   abled or disabled by clicking on the    mic     display window found on the main  screen with your left mouse button to toggle its setting     1   Insert the TacT software disc into the computers CD ROM drive    2   Start the Tact 2 2X Correction System Software on your computer    3   Select    File    from the menu selection at the top of the main software screen    4   Select    Microphone    and a new window will open    5   Select your CD Rom drive in the    Look in    menu you should now see a file in  the larger window below    6   Select the    Micxxxxx mic       file  The number in the fil
32. onal buttons to highlight the desired option  on line 2  and then press the     Enter    button to make the selection  The new sampling frequency will be  displayed in block  4      NOTE  This menu does not affect the analog output sampling frequency   Tact Audio 21    Front Panel Displa    22 Tact Audio    POL menu    TEST menu    The polarity menu allows for an independent polarity setting for each channel   Each channel can be set to          0  or          inverted         To select an option use the    UP    and    DOWN    navigational buttons and to change  its value press the    ENTER     button to toggle between a         or         setting     The test menu is designed to allow for a quick system check  When engaged it will  produce pink noise on all selected channels  1   When a channel is set to    Y    pink  noise will be heard from that channel when    Run Test    is selected        1 2    To highlight an option use the    UP    and    DOWN     navigational buttons and then  press    ENTER    button to make your selection  After all selections are made  high   light the    Run Test    option and hold down the    ENTER     button to produce the test  signal  The test tone will stop when the    ENTER     button is released  Press the     MENU    button to exit this menu     Front Panel Displa    DISPLAY menu The display menu allows for control over the front panel display appearance  To se   lect an option use the    UP    or    DOWN    navigational buttons and the
33. r   panel  including the sockets  can be exchanged to accommodate future interfaces     True Upgradeability The front panel and DSP s are 100  software driven  and improvements or new fea   tures can be loaded through the RS232 port with firmware upgrades  Itis our policy to  offer software upgrades at no cost  and we therefore encourage you to fill out and  submit the enclosed registration card by fax or email  info tactaudio com      Tact Audio 9    Digital input    Digital output 1  main channels    10 Tact Audio    RCS 2 2X Connections    The RCS 2 2X has 5 digital inputs       Three RCA  S PDIF    One AES EBU  XLR     One TosLink  S PDIF     All of the digital inputs supports PCM audio data with sampling rates from 32kHz to  96kHz  16 24 bits however  the AES EBU and RCA coaxial input also supports  192kHz        The RCS 2 2X has three digital outputs for the main channels        One RCA  S PDIF    One AES EBU  XLR     One TosLink    All outputs are 24 bits at 44 1  48  88  96 or 192 kHz sampling rates  TosLink does  not support 192kHz   The output sampling rate is set in the    DOUT    menu     The main channel output is used for your main speakers or for Mid High frequencies  when used with subwoofers  Connect one of these outputs to a TacT digital amplifier  or external DA converter        RCS 2 2X Connections    Digital output 2 The RCS 2 2X has three digital outputs for subwoofer s     subwoofers    one RCA  S PDIF     one AES EBU  XLR     one TosLink    All outputs
34. r panel mains  switch and connect the supplied measurement microphone to the    Mic Input     connector on the back of the RCS 2 2 X  Place the mic at the primary listening  position at the height of your head  This will require a microphone stand  or  something similar     CAUTION  To avoid damage through static discharge  we strongly  recommend to turn off the RCS 2 2 X at the rear panel mains switch  before connecting the microphone     4   Turn your RCS 2 2 Xon     5   Set the Mode setting for the RCS 2 2 X from the units front panel  This is the  speaker configuration your system will be using  Please refer to page 18 for  more information and instructions     6   Turn on your computer and start the TacT 2 2 X Correction System Software  If  you have not installed the software please see page 31 for instructions     7   Enable your microphone if you are using the Tact microphone that came with  your unit  To enable or disable the microphone click on the    mic     display  window found on the main screen with your left mouse button to toggle its  setting  When the microphone number is displayed it is enabled  If you have  not installed your microphone please see page 31 for instructions     Start the Quick Setup by selecting the yellow    Quick Setup    button located on the  Tact 2 2 X Room Correction System main window     The Tact 2 2 X Quick Setup wizard is broken into three steps  As you complete  each step select the    NEXT    button move to the next step     Tact
35. s  If two TacT digital ampli   fiers are connected  both options  1  and  2  should be set to ENABLED  If one Tact  digital amplifier is connected only one option should be set to ENABLED and the  other one should be set to DISABLED  Enable should only be set for the output  that uses Tact digital amplifiers     To change the settings use the    UP    and    DOWN     navigational buttons to highlight  the option and then press the    ENTER     button to change the setting      amp        CORR menu    Front Panel Displa    NOTE  When a TacT digital amplifier is controlled by the RCS 2 2X  all of  the amplifiers front panel and IR controls are disabled  Use the RS232 port  and or daisy chain to link the components     CAUTION  The AMP setting should only be set to ENABLED if you have Tact  amplifiers connected to the RCS 2 2X  When the AMP option set to ENABLED  both the analog and digital output with will output a full level signal regard   less of the RCS 2 2X master volume setting  If you do not have Tact amplifiers  connected to your system you will not be able to control the output level  from the RCS 2 2X volume control  The output is sent at its maximum level  and can result in damage to your speakers     The correction menu allows for control of all the room correction parameters  To  highlight an option use the navigation buttons and select it by pressing the     ENTER     button        1   LEVELS   DELAYS and NAMES are menu options  To enter  one of these menu options
36. sor over EQ  2   Once the cursor is  positioned over EQ  2  press the    ENTER     button  The system will then display a pull  down list containing all presets  Use the    UP    and    DOWN     navigation buttons to  point to the desired EQ preset and then press the    ENTER     button  This action will  engage the selected preset and display the new selection in the EQ box  2   Once  the cursor is positioned over EQ  2  you can also select a correction preset by  pressing one of the ten buttons located in the block labeled    CORRECTION    on the  remote control     Note  with the remote control you can only select first nine presets  To select  the rest you must use front panel controls     Front Panel Displa    Correction menu option  Move the cursor to the CORR  3  option and press the    ENTER     button to enter the  main room correction menu     Parametric EQ menu option  Move the cursor to the PAR EQ  4  option and press the    ENTER     button to enter the  main parametric EQ menu     a Note  An EQ preset must be enabled from the main screen for the PAR EQ and     TONE menus to be active  If the EQ preset is set to    BP    the PAR EQ and  TONE controls are disabled   Tone control menu option  Move the cursor to the TONE  5  option and press    ENTER     button to enter the tone  control screen     Output sampling frequency indicator  This displays the currently selected output sampling frequency  The output sampling  frequency is can be modified in the    OUT FS   
37. ted    message will be displayed   You can now close the RCS 2 2 X software and audition your nine correction  presets     Setup automation starts  This gives you time to leave the listening area       NOTE  The Quick Setup will give you a 15 second delay before the Quick  before the measurement process begins     Tact Audio 39    Step I     Removing your old  RCS2 2X Software     amp      Step Il     Install your new  RCS2 2X Software    Step III     Reprogramming the  RCS2 2X Firmware    40 Tact Audio    A       Update the RCS 2 2 X Firmware    Your RCS 2 2 X has been pre programmed with the latest firmware when shipped  from our factory and does not need to updated with the program CD that came with  your unit  TacT Audio may occasionally release updated versions of the RCS  software that will be available on our website    www tactaudio com     This new  software may contain updates or enhancements for your RCS 2 2 X  When  instructed by a technician or messaged from our website please follow the  instruction below to update your RCS 2 2 X firmware     First un install the current version of the TacT 2 2X RCS software on your computer     1   Turn on your computer    2   Open the Windows control panel and select the    Add Remove  Programs    option    3   Highlight the    TacT 2 2X    option and click on    Change Remove          4   Select    Yes    and the old 2 2X software will be removed     NOTE  Your target curves and measurements stored under unique names  will NO
38. tion threshold  SDTH   wheel speed  and remote control  To select an option  highlight it using the    UP    and    DOWN     navigational buttons  To modify a selected  option use the    LEFT    and    RIGHT     buttons          Max Level   This option controls the systems maximum signal  level  For example  if this option is set to  3 0 dB  the volume  control can not go above  3 0 dB       Detection   This option sets the signal detection threshold  If the  absolute value of the Left or the Right channel signal goes above  this threshold the red signaling dot will be displayed on the front  panel bellow the master volume display  This feature can be used  to indicate signal presence on either channel or to indicate near  clip condition  To use it as a signal presence indicator set the  Detection to a value close to  90 0 dB  To use it as near clip  indicator set the Detection to a value close to 0 0 dB     NOTE  This light does not indicate clip condition       Wheel   This option sets the wheel sensitivity  The wheel  sensitivity can be set to between 1 and 10 or to    OFF    to  disable the Wheel for volume control  The lower the setting the  slower the volume increases and the higher the setting the faster  the volume increases with each turn of the Wheel       Remote   This option enables and disables the remote control     Once the remote control is disabled the unit can only be con  trolled from the front panel     Tact Audio 25    Front Panel Displa    26 Tact Audio 
39. woofer can reproduce     36 Tact Audio    Quick Setup            If you have selected 2 0 operating mode you will need to set the       Loudspeaker lower cutoff frequency  this is the lowest frequency that your  loudspeakers can reproduce     STEP Il    Do you have one or more M S 2150 digital amplifier connected to your TacT 2 2 X     Duick etn   STEP 2         If you do not use Tact digital amplifiers select    No     Then select the    Next    button  and go to Step Ill     Tact Audio 37    Quick Setup    STEP Il    Quek Sebup   STEP 2         If one or more M S 2150 digital amplifiers are connected to your RCS 2 2 X  select    Yes     You will now need to select the options that match your RCS 2 2 X  connections to your M S 2150 amplifier s   If you have more than one digital  amplifier you will need to select more than one option          Next you will have to enter the unique address number that is assigned to each  amplifier in the    Amp panel    section  This parameter is automated to enter  address numbers 2 3  and 4 consecutively with the selection of your connected  amplifiers  The address entered for each amplifier should match the address  assigned in the    ADDR    menu of each amplifier  If you need to enter a new  address number select the address window that you want to change with your  left mouse button and enter the number that you have set for your amplifier     38 Tact Audio    Quick Setup    STEP Ill  Verify that the selections you made are correct and
40. y interface takes TacT Audio   s room correction to new heights  The RCS  2 2X has no noise and extremely low distortion  yielding amazingly transparent  accurate sound  Every effort has been made to make this preamplifier the best that  money can buy  Add to this the latest evolution of TacT Audio   s room correction  technology and the result is absolutely staggering     TacT room correction technology has been praised by the press all around the world   Comments like    Wholesale improvement in sound quality    have become a standard  phrase for reviewers describing the results that can be achieved with TacT   s room  correction  Now we have taken room correction technology even further  not only in  terms of processing power  but also in terms of the measurement and correction  systems  The measurement is now done with a triple pulse for each acquisition  This  increases the measurement resolution in both the time and frequency domains   Correction resolution is now four times higher than found in the original RCS 2 0     One of the most exciting features of the RCS 2 2X is its separate subwoofer output   The RCS 2 2X can be used with one or  preferably  two subwoofers  An electronic  crossover can be set with a frequency between 60 and 400 Hz and a slope between  12 dB octave and 60 dB octave to split the audio signal between the main and  subwoofer outputs  The correction software aligns the sub woofer s  with the main  speakers in the time domain and in the frequency d
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Avaya IP Telephony User's Manual  IOGear GCS1712 User's Manual  Autómatas Modicon Atrium TSX PCI 57 TSX  GHC - Giles  Autopilota SPX-5 a ruota  (301) user manual  Lenovo IdeaPad S10e  Remington MC R-830 User's Manual  CnMemory 8 GB Chopper  Rhino-Rack Roof Bars Installation Instructions    Copyright © All rights reserved. 