1. holes in back of the enclosure and pressing the pins in Make sure that the pins are firmly seated and the module is secure Wiring Instructions Note Module wiring should only be performed by a experienced licensed electrician Make sure all power has been shut off to the equipment and there is no live circuit Route all cables through the knock out holes and bundle with tie wraps or cable straps to ensure safe and long lasting connections 1 2 Route Category 5 phone cables from the network interface device at the phone company s demarcation point to the module Using a wire stripper strip off about 2 of the cable to expose the wires Separate the four wire pairs Using a standard 110 punchdown tool terminate the tip and ring wires at the from telcom side of the telephone hub Match each wire pair with the color codes on the IDC block white blue blue pair in line one white orange orange pair in line two white green green pair in line three white brown brown pair in line four Perform the stripping and punchdown function for wires at the output side of the telephone hub for 1 6 locations in the home lag each cable in the module with its point of destination Houte the cables from the hub to the phone fax modem locations in the home and termi nate accordingly Security System This FastHome module offers a connection to the security system that can override any phone in
2. 550 020Manual qxd 7 6 04 3 32 PM Page 1 CUETO MW COeNNECTLIVI Y PLATFORMS ML gium T B ET E url r2 9 cet 550 020 Fast Media Telephone Module 6 2 W x 27s H x 1 D Manufactured by Steren Electronics International LLC 8675 Miralani Drive San Diego CA 92126 1 800 266 3333 www steren com 550 020Manual qxd 7 6 04 3 32 PM Page 2 CIS FastHome 550 020 Telephone Hub Module Installation Guide Introduction Welcome to the FastHome Series Thank you for purchasing this product part of the FastHome Series of Fast Media Home Network Systems by Steren You have made an excellent choice for the homeowner The FastHome Series of enclosures and modules provide a quality control center for the wiring of cable TV phone fax modem Ethernet security sound system and other voice video data and audio devices Installation is easy and requires only basic tools By following the instruc tions in this guide you will ensure the proper installation of the FastHome module Product Description From a centralized location the Fast Media Telephone Hub Module distributes four incoming phone fax modem lines to six rooms The module also features an RJ 31X security system connection and an RJ 45 expansion port This module exceeds TIA EIA 568 CAT5 standards All FastHome modules feature 18 gauge cold rolled s
3. dules High quality FastHome modules Steren provide secure reliable connections for voice video data and audio applications Each module is housed in a sturdy 18 gauge cold rolled steel construction for excellent RFI shielding The system is expand able by adding multiple modules 550 010 Fast Media Telephone TV Hub Module 61 2 W x 43 4 H 1 D Fast Media Audio Splitter Module 61 2 W x 27 s H x 11D 550 100 Small Surface Mount Enclosure 7 W x 1111H x 35 16 D 550 200 Small Flush Mount Enclosure 143 3 W x 1911H 31 2 D 550 020 Fast Media Telephone Hub Module 61 2 W x 27 s H x 11D 550 060 Fast Media Ethernet Switch Module 61 2 W x 23 4 H x 11D STEREN 550 105 Large Surface Mount Enclosure 149 6 W x 19 H x 45Ae D 550 205 Medium Flush Mount Enclosure 143 3 W x 321H x 7 D 550 030 Fast Media Data Hub Module MAE 27 s H 1700 550 070 Fast Media Power Module 61 7 W 25 8 1H x 11D 550 210 Large Flush Mount Enclosure 14 s W x 44 H x 2 D 550 040 Fast Media TV Combiner Splitter Module 61 2 W x 27 s H 1 D ce 550 080 Fast Media RF Modulator Module 61 2 W x 31H x 23 s D Manufactured by Steren Electronics International LLC 8675 Miralani Drive San Diego CA 92126 1 800 266 3333 www steren com Made in China
4. e connected to a live circuit 2 do not install wires or electrical equipment Systems are produced with during a lightning storm 3 do not install wires or electrical equipment or their superior design and engineering enclosures near water or locations where water is used in the kitchen bathroom high quality materials and excep laundry room swimming pool etc 4 do not install electrical components or equip tional manufacturing processes ment in wet areas unless specifically rated for moisture attributes that are synonymous e Make sure all wires in the modules are properly connected or terminated with the Steren name AONE D STEREN Fast Media Home Network Systems Revised 06 04 FASTHOME rs ML 550 020Manual qxd 7 6 04 3 32 PM Page 3 CIS FastHome 550 020 Telephone Hub Module Installation Guide Pre Installation Instructions 1 After the enclosure has been mounted determine which modules will be inserted On a sheet of paper diagram the location where each module will be placed An expansion module should be placed close to the module with which it interfaces On the diagram identify the origin and destination of each cable Make sure the module serving each device is safely within a 100ft 30m distance Installation Instructions 1 2 Identify the enclosure location on which the module will be mounted Mount the module by inserting the nylon pins into the
5. teel construction for excellent RFI shielding Contents of Package 1 Fast Media Telephone Hub Module 2 Installation manual Tools for Module Installation and Wiring 1 Wire stripper 2 Punchdown tool Standard 110 3 Personal protective equipment Punchdown Tool Safety Instructions Read these safety instructions before installing this module and follow them carefully Keep these instructions handy and refer to them when working on the module e Always wear the necessary personal protective gear and follow all About Steren Electronics basic precautions and safety procedures when working with wires and electrical equipment using power tools or working in unfinished Based in San Diego Steren construction areas has been a leading component Use caution when handling this module Be careful not to drop the manufacturer for nearly 50 years module because this could affect the performance and or damage With more than 2 000 items the module in our catalog we supply inter Take extra precautions when working with cables wires and tools connect products and electronics pui ds and a s to be damaged Avoid accessories for home and ud ng an ara a T x m commerci Tuse e careful when using tools that might touch exposed wires or live electrical contacts The FastHome Series e To prevent electric shock 1 do not touch uninsulated wires and terminals that of Fast Media Home Network may still b
6. use and alert the security service provider of an emergency To enable this function connect the security system cable to the module s RJ 31X jack located below the expansion port Refer to the manual from the security system manufacturer for specific instructions and safety information STEREN LIN ML Fast Media Home Network Systems Revised 06 04 Installation OX o Sample configuration for telephone audio video security and Ethernet For More Information about FastHome and Fast Media Home Network Systems contact Steren Electronics International LLC 8675 Miralani Drive San Diego CA 92126 1 800 266 3333 www steren com Copyright 2004 Steren Electronics International LLC Printed in China 176104 E 550 020Manual qxd p E CUSTOM CONNECTIVITY PLATFORMS 3 32 PM Page 4 Fast Media Home Network Systems For your future construction needs consider the entire series of FastHome Enclosures and Modules Enclosures From centralized location Fast Media Home Network Systems enclosures fully inte grate manage and distribute broadband and multimedia serv ices on a flexible customizable and upgradeable platform Constructed of 18 gauge cold rolled steel for strength and protection against interference FastHome enclosures mount on a wall surface mount or between 16 center wall studs flush mount FastHome Mo