Home
Spectra QM95 User's Manual
Contents
1. www trimble com spectra Quick Start Guide QM95 Quick Measure Distance Meter User Guide Trimble Introduction Thank you for choosing the Spectra Precision QM95 from the Trimble family of precision products This easy to use distance measuring tool will allow you to measure distances quickly accurately and reliably Before using the Quick Measure read this operator s manual carefully Included is information about operation safety and maintenance Ensure that the operating instructions are with the laser distance meter when it is given to other persons Your comments and suggestions are welcome please contact us at Trimble Spectra Precision Division 8261 State Route 235 Dayton Ohio 45424 USA Phone 1 937 203 4419 1 800 527 3771 Fax 1 937 482 0030 Internet www trimble com spectra Single Measure Continuous Measure Change measure reference Area Short e eC mm w wp Subtraction ge rene of measure Long Cycle through units change i eee 10 Features Power ON OFF Measure reference Liquid Crystal Display LCD Measure Buton Add Button Clear Button Subtract Button Area Button Battery Access z N e a i Tann Side Measure f oo Button i ral i 3 Protective Flip out tab overmolding 4 extension el 3 Features LCD Detail 3 112m 12 324m 8 235m 6 507m 3rd prior measu
2. Clear button Press the C button to clear the last reading During area measures the C button clears the most recent measure but preserves previous measures 13 General Care Safety And Storage General safety rules a Check the condition of the tool before use b The user must check the accuracy of the tool after it has been dropped or subjected to other mechanical stresses c Although the tool is designed for the tough conditions of jobsite use as with other measuring instruments it should be treated with care Do not use prisms or mirrored surfaces Distances can be measured from all stationary targets without a highly reflective surface i e concrete stone wood plastic paper etc The use of prisms or other highly reflective targets is not permissible and if attempted may falsify the results Calibration Check It is recommended to occasionally check the calibration of the tool 1 Select a known measure distance about 1 to 5 meters 3 to 15 ft that does not change over time 2 Measure the distance 10 times Calculate the mean deviation from the actual distance The measured mean deviation should be less than the typical accuracy tolerance of 1 5 mm 1 16 in van Laser Safety Use of this product by people other than those trained on this product may result in exposure to hazardous laser light e Do not remove warning labels from the unit e The QM95 is a Class 2M 635 nm laser product e
3. after a long period of storage or transportation Transport Use the original packaging or packaging of equivalent quality for transporting or shipping your equipment CAUTION Always remove the batteries before shipping the tool 18 Warranty Trimble warrants the Quick Measure QM95 to be free of defects in material and workmanship for a period of 3 years For the first 2 years Trimble or its authorized Dealer or Service Center will repair or replace at its option any defective part or the entire product for which notice has been given during the warranty period For the 3rd year an exchange fee may apply This warranty period is in effect from the date the system is delivered by Trimble or its authorized Dealer to the purchaser or is put into service by a Dealer as a demonstrator or rental component Any evidence of negligent or abnormal use or any attempt to repair equipment by other than factory authorized personnel or Trimble certified or recommended parts automatically voids the warranty The foregoing states the entire liability of Trimble regarding the purchase and use of its equipment Trimble will not be held responsible for any consequential loss or damage of any kind This warranty is in lieu of all other warranties except as set forth above including an implied warranty Merchantability of fitness for a particular purpose is hereby disclaimed Customers should send products to the nearest authorized Fact
4. Never look into the laser beam or direct it to the eyes of other people e Always operate the unit in a way that prevents the beam from getting into people s eyes ee ete Trim Titia Maehgerior Lid Diya dna LL CAUTION a AN DIN EN 60825 2008 aioe CP D Er a D tera r EA FE A Power I 400m Suta Number a1 Settings menu to change sound and unit of measure 1 With the tool switched off press and hold the Power On Off Button for approximately 2 seconds to enter menu mode 2 Press to cycle sound on or off 3 Press the button to cycle through unit measure options BE ft TL 4 To close the menu press and hold the Power On Off Button for approximately 2 seconds The tool is switched off and settings are saved 14 Cleaning and drying 1 Blow dust off the lens 2 Do not touch the lens with the fingers 3 Use only a clean soft cloth for cleaning If necessary moisten the cloth slightly with pure alcohol or a little water NOTE Do not use any other liquids as these may damage the plastic components Storage The temperature limits for storage of your equipment must be observed especially in winter summer Remove the tool from its pouch if it has become wet The tool its carrying case and accessories should be cleaned and dried at maximum 40 C Repack the equipment only once it is completely dry Check the accuracy of the equipment before it is used
5. ory Dealer or Service Center for warranty repairs freight prepaid In countries with Trimble Service Subsidiary Centers the repaired products will be returned to the customer freight prepaid 22 Specifications Measurement range Distance performance and measure speed is dependent upon several Measuring Range 0 1 to 200 m 1 to 650 ft factors 1 0 mm typical 1 24 in e Ambient lighting Individual measure Continuous measure Area Addition Subtraction Automatic shut off Battery life alkaline LCD 4 segments 100 75 50 25 Class II as per EN 60825 1 2007 IEC 60825 1 2007 CFR 21 1040 FDA Dimensions 62 x 28 5 x 120 mm 2 4 x 1 2 x 4 7 217 g 7 7 oz with batteries Dependent upon several factors See table next page Accuracy Functions Target reflectivity e Dust and particles in the air Measure reference e Temperature ngeon Operating temperature Storage temperature Power supply Power indication Laser Safety Cto 100000 kx 0 17 to 50 m 10 C to 50 C 100000 Ix 0 17 to 45 m 10 C to 50 C 100000 Ix 0 17 to 45 m Minimum measuring distance 170 mm Laser Type Power 15 16 Trouble Shooting The batteries are exhausted Replace the batteries Incorrect battery polarity Insert the batteries correctly and close the battery compartment cover Frequent error messages or the unit doesn t The target surface is too brightly lit by the s
6. re 2nd prior measure Previous measure Current measure Units of measure General Operation Single distance measurement 1 Switch on the laser beam by pressing the Measure Button 2 Point the laser dot to the surface to be measured Default measure reference is from bottom of the tool 3 Press the Measure Button once again The measured distance will be displayed 4 Press the Power On Off Button to switch off Continuous measurement 1 Press and hold the Measure Button for 2 seconds to activate continuous measuring mode The tool beeps during continuous measure mode if beeper is turned on 2 Press the Measure Button again to stop continuous measure When continuous measure is stopped the last valid distance measurement is displayed on the result line Continuous measure can be useful to find the shortest distance to a wall or longest distance to a corner as shown i Included with the QM95 Pouch unit battery user guide Batteries Installation 1 Open the battery compartment 2 Remove the batteries from the packaging and insert them in the tool NOTE When installing batteries note the positive and negative markings on the housings 3 Close the battery compartment cover Battery disposal Some areas have regulations regarding the disposal of batteries Be sure to dispose of discharged batteries properly CAUTION The batteries should be removed when storing the laser mo
7. re than 30 days oe Features LCD Detail X Indicates laser is activated Indicates measure reference is from back Indicates measure reference is from front Automatic detection of tab extension and indicates measure reference is from extension More bars indicate more battery power remaining Flashing indicates it is time to change batteries Unfavorable signal conditions Hardware error Switch unit on off several time If this symbol remains contact your dealer Temperature too high or too low z Power on off options 1 The Quick Measure is designed to allow quick measurements by pressing the Measure Button to switch on the tool and activate the laser In this case measurement is accomplished when the Measure Button is pressed the second time 2 It is also possible to use the power button to switch on the tool In this case the Measure Button must be pressed once to activate the laser and a second time to accomplish a measurement Area 1 Press the measure button to turn on the unit or the Clear button to clear 2 Press the Area button 3 Press the Measure button to measure the first side as shown on the LCD screen 4 Press the Measure button to measure the second side as shown on the LCD screen The Area will be shown along with both measures 2 General Operation Addition and Subtraction The next measure is added to the previous one The next measure is subtracted from the previous one
8. rimble com cn Trimble Kaiserslautern GmbH Am Sportplatz 5 67661 Kaiserslautern GERMANY Tel 49 0 6301 71 14 14 Fax 49 06301 32213 Africa amp Middle East Trimble Export Middle East PO Box 17760 JAFZ View Dubai UAE 97 1 4 881 3005 Phone 97 1 4 881 3007 Fax 23 20 Declarations We declare on our sole responsibility that this product complies with the following directives and standards EN 50081 1 EN 61000 6 2 2004 108 EC Designation Laser range meter Type QM95 Notice to Our European Union Customers For product recycling instructions and more information please go to www trimble com environment summary html Recycling in Europe To recycle Trimble WEEE call 31 497 53 2430 and ask for the WEEE associate or mail a request for recycling instructions to Trimble Europe BV c o Menlo Worldwide Logistics Meerheide 45 5521 DZ Eersel NL Trimble CEO 2012 Trimble Navigation Limited All rights reserved Reorder PN 1213 1220 Rev A 09 12
9. un Bright sunlight towards the tool Temperature too high gt 50 C 122 F Temperature too low lt 10 C 14 F Allow the unit to warm up The unit cant be switched on No distances displayed by the unit Measure Button was not pressed Unit was not switched on Faulty display Temperature indicator symbol in the display Unfavorable signal conditions symbol in the Insufficient reflected laser light Observe the minimum measuring distance gt 200 display mm 8 inch from the front edge of the unit clean the lenses take the measurement from a different surface or use a target plate General hardware fault symbol in the display Hardware fault Switch the unit off and on again 19 Service Request To locate your local dealer or authorized Trimble Service Center outside the U S A for service accessories or spare parts contact one of our offices listed below Asia Pacific Trimble Navigation Singapore PTE Ltd 8261 State Route 235 80 Marine Parade Road 22 06 Dayton Ohio 45424 6383 Parkway Parade U S A Singapore 449269 888 527 3771 65 6348 2212 Phone Toll Free in U S A 65 6348 2232 Fax 1 937 203 4419 Phone China 1 937 482 0030 Fax North Latin America Trimble Spectra Precision Division i Trimble Beijing trimble com spectra Room 2805 07 Tengda Plaza Europe No 168 Xiwai Street Haidian District Beijing China 100044 86 10 8857 7575 Phone 86 10 8857 7161 Fax www t
Download Pdf Manuals
Related Search
Related Contents
Graco Inc. 311911C Paint Sprayer User Manual Pharos Science & Applications 135 User's Manual N∞ 107 - Corenc Bureau Communautaire du 05 septembre 2013 iiView 1000DV User's Manual Manuel d`installation d`utilisation et de maintenance Acer MMP3400 User's Manual UV COB Cannon Olympus VH-210 Copyright © All rights reserved.