Home

SkyLink HA-318 User's Manual

image

Contents

1. refer to Section 3 Walk Test to determine the best mounting angle Insert a 9V alkaline battery not included to the motion sensor and its LED will be on for 2 seconds The receiver will beep and red LED flash The sensor requires a warm up time of approx 45 seconds before it can function properly After powering up the sensor face it to the wall where no motion will be od y 7 i detected After 45 seconds the sensor is ready Wave your hand in front of the sensor the receiver will SOMONIY D ow na a ae leer ee ee Section 3 Walk Test If the walk test result is satisfied the Shik Ace emg i sensitivity does not require to be adjusted further If the walk approx 15 seconds a ae test result shows the sensitivity is too low then you can change i Plug in the adapter to the receiver x J lal A j the green LED will start flashing 4 i i t aft p h j indicating the receiver unit is Ka ih ee eet powered up but no sensor is x oe a detected Sensitivity Connectors Plug in the adapter to the receiver Insert 9V alkaline battery to the sensor on Motion Sensor Diagram 2 Diagram 1 3 POWER UP THE INDOOR OUTDOOR MOTION SENSOR AND RECEIVER CONT 4 WALK TEST After mounting the sensor at the desired location it is important to perform a walk test in order to determine if the sensor is detecting the things you want to detect In order to control how far the sensor can see this can be done by adju
2. Motion Alert Model HA 318 1 INTRODUCTION The Motion Alert is designed to monitor movement around your house The motion sensor can be placed either indoor or outdoor Once motion is detected the receiver will beep amp flash In this package you should find an Indoor Outdoor Motion Sensor a Houselink Receiver an adapter ball head joint screws and a clip 2 SET UP THE INDOOR OUTDOOR MOTION SENSOR AND HOUSELINK RECEIVER 1 CODE CONNECTORS In order for the sensor to communicate with the receiver properly the sensor s code must match with the receivers code Code connectors 1 to 6 can be found by opening the battery cover and back cover of the receiver User is required to set these code connectors randomly and the code settings on both sensor and receiver must be the same Each position of the code connector 2 ZONE CONNECTORS Each receiver can work with up to 4 different sensors to represent 4 different zones on the receiver There are 2 connectors that determine the zone number 1 2 3 and 4 These 2 connectors can be found by opening the battery cover Please follow table 1 to set the zone can be set to or O positions Refer to the diagram below to set the code connectors properly Note A connector can be removed with the clip as shown Ball head joint Indoor Outdoor Motion Sensor 5 Adapter Table 1 Zone connectors Houselink Clip Receiver Code Connect
3. flash and the receiver will emit a continuous 4 beeps i e beep beep beep beep pause beep beep beep beep pause etc By the number of beeps emitted by the receiver user can identify which zone is triggered 5 BUZZER VOLUME You can select the buzzer volume by m switching the volume switch to HI or i LO position The buzzer can be disabled by switching to the OFF position z 9 FCC The Houselink receiver can work with up to 4 different sensors This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device garage door monitor sensors door window sensors water may not cause harmful interference and 2 This device must accept any interference received including interference that sensors indoor outdoor motion sensors etc Please visit www skylinkhome com or contact us at support skylinkhome com WARNING may cause undesired operation for more information of how to fully utilize your Motion Alert Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation Th
4. is equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment dose cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 6 MUTE When a sensor is triggered for a long period of time you may stop the buzzer by pressing the mute button When another signal comes again you can disable the buzzer for all currently activated sensors by pressing the mute button The receive will beep again if it receives another signal For instance if you are working on your lawn with the garage door open you may iz want to disable the buzzer for this garage door only Then you can press the Mute z button after it starts to sound If any other sensor is triggered the receiver will sound iW 5 7 LOSS OF SIGNAL INDICATION When the battery le
5. ors on Receiver 2 pcs 3 x 18 screws Code Connectors on Motion Sensor Included in the table means the connector for that position should be placed on the posts Note If you experience interference from a nearby system which could accidentally trigger your l 7 in the table means the connector for that position should be removed system please change the code settings on the sensor and receiver The code setting on the Pea EIO OW AE Mo CHO MSc Oe ow ese CID OU MORON SENT sensor and receiver should still match after changing the code setting and the receiver 3 POWER UP THE INDOOR OUTDOOR MOTION SENSOR AND RECEIVER 2 SENSOR SENSITIVITY The sensitivity of the motion sensor is adjustable Change the setting by placing the connector on either the High or Low position When the sensitivity is set to Low more movement is required to trigger the sensor It is recommended to set the 1 POWER UP After setting up all the connectors properly both units are now ready to be powered up 3 MOUNTING A ball head joint is necessary to mount the sensor at a desire location A height of 5 6 ft is recommended depending on your application Once a location is selected mount the ball head joint to this location by screws provided see diagram 1 Once the ball head joint is mounted to the wall slide the back of the sensor into the ball head joint see diagram 2 The mounting angle can be adjusted Please
6. sting the angle of the sensor To reduce the detection range simply move the sensor downward To increase the range move the sensor up to around 12 degrees This will give the maximum range However this may not be desired if the sensor is placed outdoors since a false trigger may occur if the sensor is set to detect motion in a distance You should walk in the area that you would like the sensor to monitor The receiver will beep if the sensor detects your movement If the receiver does not respond adjust the mounting angle accordingly Perform the walk test again after 30 seconds Repeat this procedure until your motion is detected There should be no movement in the detected area during the 30 seconds Perform walk test in the undesired area to ensure movement cannot be detected Tips The sensor should not face towards direct sunlight placing near heat or cold producing devices i e A C or furnance vents fans ovens heaters etc that may cause false triggers 8 OTHER HOUSEHOLD ALERT SENSORS 4 OPERATION When motion is detected in the monitored area the sensor will send a signal to the receiver It will beep and the corresponding zone red LED will flash for 15 seconds If the sensor is set to zone 1 zone 1 red LED on the receiver will flash and the receiver will emit a continuous single beep i e beep pause beep pause etc If the sensor is set to zone 4 zone 4 red LED will
7. vel on the sensor drops to a certain level or the sensor is out of the operating range the receiver will show a loss of signal indication The red LED representing that zone will flash rapidly i e if zone 1 sensor is lost the zone 1 red LED will flash rapidly When the loss of signal indication occurs move the receiver closer to the corresponding sensor and trigger that sensor If the red LED stops flash ing rapidly that means the receiver or sensor needs to be relocated If the loss of signal indication persists replace the battery of that sensor 10 WARRANTY If within one year from date of purchase this product should become defective except battery due to faulty workmanship or materials it will be repaired or replaced without charge Proof of purchase and a Return Authorization are required 11 CUSTOMER SERVICE If you would like to order Skylink s products or have difficulty getting them to work please 1 visit our FAQ website at www skylinkhome com or 2 email us at support skylinkhome com reply within 24 hrs or 3 call our toll free at 1 800 304 1187 from Monday to Friday 9 am to 5 pm EST Fax 800 286 1320 CUSTOMER SERVICE Email support skylinkhome com Reply within 24 hrs http Awww skylinkhome com P N 101A205 002 Rev 2 2003 SKYLINK GROUP