Home
Simer Pumps 3075SS User's Manual
Contents
1. B Il faut tre extr mement prudent lorsqu on remplace un fusible Pour r duire les possibilit s de secousses lec triques mortelles NE PAS se tenir dans l eau et ne pas met tre de doigt dans la douille du fusible C Mettre la terre la bo te de sortie de la prise de courant D Ne brancher la pompe et son servor gulateur que dans une prise de courant ad quatement mise la terre pro t g e par un interrupteur de fuite la terre Pour obtenir des pi ces ou de l aide appeler le Service la client le Simer en composant le 800 468 7867 1 800 546 7867 Table des matieres Merci d avoir achet une pompe de qualit sup rieure mise Pessai l usine Consignes de s curit g n rales ssh RE ee 10 Garantie a it nee etat strass 11 Renseignements gen rdUX 2222 2228 2 4 oa De RAA Re EEE lat Re 12 Installation calada 12 13 Branchements elector edi sas 14 SEOANE A A E 14 FOMCUONMEMEMNE sissies evans diana ia nana labs panas men tates eme REE ESTRE een des 14 Quand la pompe cesse t elle de fonctionner 14 15 Entr tien RN 15 D pannage rss dt di 15 PISCES DETECTA EE T A en aes ee airs ne a 16 Garantie limit e Simer SIMER garantit l acheteur utilisateur initial Acheteur que ses produits sont exempts de tout d faut de fabrication et de mat riaux Tout produit reconnu d fectueux dans les douze 12 mois qui suivent la date d acha
2. Pour obtenir des pi ces ou de l aide appeler le Service la client le Simer en composant le 800 468 7867 1 800 546 7867 Renseignements g n raux et Installation 12 Utiliser cette pompe PressureMate pour augmenter la pression de l eau fournit par la municipalit Les branchements de la tuyauterie sont d crits dans cette Notice RENSEIGNEMENTS G N RAUX Ne pomper que de l eau propre avec cette pompe PressureMate Pour ne pas boucher la pompe et pour ne pas endommager le joint de son arbre ne pas pomper d eau contenant des mati res solides des corps trangers du sable du limon ou des substances abrasives e Si on doit augmenter la pression de l eau pomp e d un puits s assurer que les clapets de non retour du syst me sont bien serr s Si la pression du syst me chute pendant que la pompe du puits ne fonctionne pas la pompe PressureMate peut d marrer et s arr ter continuellement Des d marrages et des arr ts rapides ou excessifs de la pompe PressureMate risquent d endommager son moteur ce qui annulera la garantie e Ne pas utiliser de p te pour raccords filet s sur les orifices filet s de la pompe N utiliser que du ruban d tanch it au t flon pour rendre tanches ces filets Les p tes d tanch it pour raccords filet s endommageront les mat riaux du ser vor gulateur NOTA Le bouchon d amorcage est d j dot d un joint torique il n est donc pas n cessaire de le rendre tan
3. Vers l habitation Arriv e d eau Figure 3 Branchement type de la tuyauterie de d riva tion pour permettre la d pose de la pompe au cas o elle devrait tre r par e sans avoir fermer toute l ali mentation d eau de l habitation Pour obtenir des pi ces ou de l aide appeler le Service la client le Simer en composant le 800 468 7867 1 800 546 7867 Installation et fonctionnement BRANCHEMENTS LECTRIQUES Tension dangereuse Ne brancher cette pompe que dans une prise de courant ad quatement mise la terre prot g e par un interrupteur de fuite la terre et ali ment e en courant alternatif de 115 volts 60 Hz Cette pompe est livr e avec un cordon lectrique 3 conducteurs dont un de mise terre et une fiche 3 broches Ne pas mod ifier ni enlever la fiche S assurer que la prise de courant corre spond selon le cas au National Electric Code ou au Code canadien de l lectricit Pour ne pas subir de secousses lec triques dangereuses toujours garder le cordon lectrique sec Se reporter la Figure 2 SERVOR GULATEUR Le servor gulateur est mont sur la pompe Il prot ge la pompe contre e Un fonctionnement sec e Toute surchauffe e Des d marrages fr quents caus s par de petites pertes d eau dans le syst me e Les chutes de pression Le servor gulateur se caract rise par les t moins lectrolumi nescents et les commandes suivants T
4. ar las piezas internas de la bomba recalentarla lo que provo car a quemaduras a las personas que estuviesen trabajando con la bomba o repar ndola y anular la garant a 6 ADVERTENCIA Riesgo de incendio o de explosi n Para evitar el riesgo de incendio y explosi n bombee agua sola mente con esta bomba No bombee l quidos ni sustancias qu micas inflamables No use la bomba cerca de luces 18 piloto de gas o en reas en presencia de vapores qu micos o de gases El uso de una bomba el ctrica con l quidos que no sean agua o en una atm sfera que contenga vapores qu micos o gases podr inflamar esos l quidos o gases provocando lesiones o muerte debido a una explosi n y o un incendio 7 A ADVERTENCIA Peligro de quemaduras Si el agua queda atrapada en la bomba durante el funcionamiento sta se puede convertir en vapor El vapor atrapado puede con ducir a una explosi n y a quemaduras Nunca deje mar char la bomba con la llave de salida cerrada u obstruida 8 PRECAUCI N No toque un motor en funcionamien to Los motores modernos est n dise ados para funcionar a altas temperaturas Para evitar quemaduras durante las reparaciones y el mantenimiento de la bomba deje que se enfr e durante 20 minutos despu s de apagarla y antes de intentar manipularla INSTRUCCIONES DE SEGURIDAD ASOCIADAS CON LA ELECTRICIDAD La bomba viene provista de un cord n de 3 conductores
5. e Press and release the RESET button e The PUMP ON LED should light up and e The TEMPERATURE FAILURE LED should stop flashing e If not let it cool some more and retry NOTE If the pump continues to run hot shut it off and call Simer Customer Service at 1 800 468 7867 LUBRICATION The motor is lubricated at the factory for the life of the bearings The pump seal is water cooled and self lubricating PUMP SERVICE 44 WARNING Hazardous voltage Can shock burn or cause death Unplug the pump and controller before ser vicing them Do not handle the pump or controller or attempt to work on the pump with wet hands or while standing on a wet or damp floor The motor has an auto reset thermal overload protector If the motor overheats the overload will cut off the power to prevent damage and will reset after the motor cools If the overload trips repeatedly check the pump for the cause low voltage a clogged impeller etc SYMPTOM POSSIBLE CAUSE S CORRECTIVE ACTION Motor will not run Fuse is blown or circuit breaker tripped Power cord not plugged in DISCONNECT POWER Replace fuse or reset circuit breaker Plug into 115 Volt grounded outlet Motor runs hot and overload kicks off or motor does not run and only hums Voltage is too low Impeller not moving freely Check voltage being supplied to pump Check that impeller moves freely and is not clogged Motor runs b
6. moin lectroluminescent POWER ON Sous tension Il indique que l appareil est lectriquement branch et qu il est ali ment en courant lectrique La pompe est pr te fonctionner T moin lectroluminescent PUMP ON Pompe en marche Il indique que la pompe fonctionne et qu elle pompe de l eau T moin lectroluminescent WATER FAILURE Manque d eau Il indique que la pompe n est pas aliment e en eau T moin lectroluminescent TEMPERATURE FAILURE Panne de temp rature Il indique que la temp rature l int rieur de la pompe a atteint 70 C 158 F Manette rotative de r glage de la pression STARTING PRES SURE Pression de d marrage Elle permet de r gler la pres R enclenchement T moin Manque d eau _ T moin Panne de temp rature Fat T moin Pompe en marche ee D gt lt A T moin Sous tension aa lm Manette rotative de r glage de la pression Figure 4 Panneau des commandes du servor gulateur 14 sion du syst me entre 103 et 310 kPa entre 15 et 45 Ib po La pompe d marrera automatiquement d s que la pression du syst me chutera sous la pression r gl e avec la manette rotative STARTING PRESSURE Pression de d marrage Touche RESET R enclenchement Elle permet de r en clencher les caract ristiques s curit qui se sont d clench es et a la pompe de red marrer NOTA Le servor gul
7. Simer Customer Service at 1 800 468 7867 1 800 546 7867 S curit LIRE TOUTES CES CONSIGNES DE SECURITE ET LES RESPECTER Ce symbole indique qu il faut tre prudent Lorsque ce symbole appara t sur la pompe ou dans cette Notice rechercher une des mises en garde qui suivent car elles indiquent un potentiel possible de blessures corporelles SAN avertit d un danger qui causera des blessures corporelles la mort ou des dommages mat riels importants si on l ignore A AVERTISSEMENT avertit d un danger qui risque de causer des blessures corporelles la mort ou des dommages mat riels importants si on l ignore A ATTENTION avertit d un danger qui causera ou qui ris quera de causer des blessures corporelles la mort ou des dom mages mat riels importants si on l ignore Le mot NOTA indique des instructions sp ciales et importantes n ayant aucun rapport avec les dangers Lire attentivement toutes les consignes de s curit contenues dans cette Notice et coll es sur la pompe Garder les autocollants de s curit en bon tat les remplacer s ils manquent ou s ils ont t endommag s Rendre les ateliers l preuve des enfants poser des cadenas et des interrupteurs principaux enlever la cl des d marreurs CONSIGNES DE S CURIT G N RALES 1 Pour viter tout risque de blessures corporelles graves et de dommages mat riels importants lire attentivement ces consignes
8. after the dis covery of any alleged defect SIMER will subsequently take corrective action as promptly as reasonably possible No requests for service under this warranty will be accepted if received more than 30 days after the term of the warranty This warranty sets forth SIMER s sole obligation and purchaser s exclusive rem edy for defective products SIMER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL INCIDENTAL OR CONTINGENT DAMAGES WHATSOEVER THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICABLE EXPRESS WARRANTIES PROVIDED HEREIN Some states do not allow the exclusion or limitation of incidental or conse quential damages or limitations on how long an implied warranty lasts so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state SIMER 293 Wright St Delavan WI U S A 53115 Phone 1 800 468 7867 1 800 546 7867 Fax 1 800 390 5351 For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867 General Information Installation 4 Use the 307555 to boost city water pressure Plumbing connections are described in this manual o INFORMATION Pump only clean wat
9. d s que la pompe d marre la pression de l eau augmente tr s rapidement et le servor gulateur d tecte qu il y a d bit S il n y a pas de d bit d eau pas et si la pression dans le syst me n augmente pas le servor gulateur a d tect qu il y a manque d eau Il peut galement d tecter cette situation pendant que la pompe fonctionne si l eau cesse de parvenir la pompe Pour prot ger la pompe contre un fonctionnement sec e 15 secondes apr s que le servor gulateur aura d tect qu il ny a pas d eau la pompe cessera de fonctionner Le t moin lectroluminescent PUMP ON Pompe en marche s teindra et Le t moin lectroluminescent WATER FAILURE Manque d eau clignotera Red marrage S assurer que la conduite d aspiration n est pas obstru e et qu elle est bien branch e sur une source d eau e Appuyer sur la touche RESET R enclenchement et la tenir appuy e e Le t moin lectroluminescent PUMP ON Pompe en marche doit s allumer et e Le t moin lectroluminescent WATER FAILURE Manque d eau doit cesser de clignoter Si le d bit est ad quat la pompe continuera de fonctionner pen dant 15 secondes apr s qu elle aura atteint la pression r gl e et que le ou les robinets de l habitation auront t ferm s Temp rature lev e D s de la temp rature de l eau l in t rieur de la pompe atteint 70 C 158 F e La pompe
10. de d marrage et apr s que le ou les robinets de l habitation auront t ferm s QUAND LA POMPE CESSE T ELLE DE FONCTIONNER R glage de la pression Plus de d bit La pompe cesse de fonc tionner et le t moin lectroluminescent PUMP ON Pompe en marche s teint 15 secondes apr s e D s que la pression dans le syst me est sup rieure la pres sion r gl e avec la manette rotative STARTING PRESSURE Pression de d marrage et e Que le ou les robinets de l habitation auront t ferm s Ce fonctionnement est normal Red marrage D s que le d bit est sup rieur 1 gal min ou d s que la pression chute sous le r glage de la pression STARTING PRESSURE Pression de d marrage la pompe red marre et le t moin lectroluminescent PUMP ON Pompe en marche s allume La pompe continuera de fonc tionner pendant 15 secondes apr s e Que la pression aura atteint la pression r gl e et e Que le ou les robinets de l habitation auront t ferm s NOTA Ce d lai de 15 secondes avant que la pompe s arr te emp che des fonctionnements et des arr ts rapides d s qu on ouvre et ferme rapidement un robinet par exemple pendant qu on se brosse les dents Pour obtenir des pi ces ou de l aide appeler le Service la client le Simer en composant le 800 468 7867 1 800 546 7867 Fonctionnement entretien et d pannage Chute de pression Plus de d bit Normalement
11. de s curit avant de proc der l installation de la pompe 2 Pour installer cette pompe respecter les codes de la plomberie du b timent et de l lectricit de la municipalit et du gouvernement f d ral Pour installer cette pompe n utiliser que des tuyaux rigides 3 A AVERTISSEMENT Pression dangereuse Le corps de la pompe risque d exploser si la pompe est utilis e pour aug menter la pression plus de 689 kPa 100 Ib po Sur la tuyauterie de refoulement poser une soupape de s ret qui permettra d vacuer tout le d bit de la pompe une pres sion de 689 kPa 100 lb po Si cet nonc est contraire aux codes respecter ce qui est stipul par les codes Ne pas utiliser cette pompe si la pression d arriv e de l eau est sup rieure 345 kPa 50 lb po 4 Il est recommand d utiliser un disjoncteur de s curit basse pression pour couper le courant alimentant la pompe au cas o la pression de refoulement chuterait suite une interruption de l arriv e de l eau d alimentation un tuyau bris etc 5 Ne jamais faire fonctionner la pompe sec sinon ses pi ces internes risquent d tre endommag es la pompe risque de surchauffer et les personnes qui manipuleront ou interviendront sur la pompe risqueront d tre br l es De plus cette pratique annule la garantie 6 A AVERTISSEMENT Risque d incendie ou d explosion Pour emp cher tout risque d incendie ou d
12. evitar que marche en seco e 15 segundos despu s de haber detectado el estado de falta de agua la bomba dejar de funcionar e Se apagar la luz de BOMBA ENCENDIDA y e La luz de FALLA DE AGUA comenzar a centellear Reinicio Aseg rese de que la l nea de aspiraci n no est obstruida y que est conectada a una fuente de suministro de agua e Oprima y suelte el bot n de REPOSICI N e La luz de BOMBA ENCENDIDA se deber encender y e La luz de FALLA DE AGUA deber dejar de centellear Si el flujo es adecuado la bomba funcionar hasta 15 segundos despu s de que alcance la presi n del punto de referencia y el flujo se detenga Temperatura alta Cuando la temperatura del agua dentro de la bomba alcanza los 158 F 70 C e La bomba dejar de funcionar e La luz de BOMBA ENCENDIDA se apagar y e La luz de FALLA DE TEMPERATURA comenzar a centel lear Reinicio Espere 20 minutos para permitir que la temperatura del agua caiga por debajo de los 104 F 40 C e Aseg rese de que la bomba est provista de agua y que el flujo no tenga obstrucciones e Oprima y suelte el bot n de REPOSICI N LOCALIZACI N DE FALLAS 23 e La luz de BOMBA ENCENDIDA se deber encender y e La luz de FALLA DE TEMPERATURA deber dejar de centellear e De lo contrario deje que se enfr e por m s tiempo y vuel va a tratar NOTA Si la bomba con
13. explosion ne pom per que de l eau avec cette pompe Ne pas pomper de liq 10 uides inflammables ni de produits chimiques Ne pas utilis er cette pompe pr s de veilleuses fonctionnant au gaz ni en pr sence de vapeurs de produits chimiques d essence ou de tout autre produit inflammable L utilisation d une lectropompe pour pomper des liquides autres que de l eau ou dans une atmosph re contenant des vapeurs de produits chimiques d essence ou de tout autre produit inflammable risque d enflammer ces liquides ou ces vapeurs et de causer des blessures voire la mort suite une explosion et ou un incendie 7 A AVERTISSEMENT Risque de br lures Si de l eau reste emprisonn e dans la pompe pendant qu elle fonctionne cette eau risque de se transformer en vapeur La vapeur emprisonn e dans la pompe risque de provoquer une explosion et des br lures Ne jamais faire fonctionner la pompe si son refoulement est ferm ou obstru 8 A ATTENTION Ke pas toucher un moteur pendant qu il fonctionne Les moteurs modernes sont con us pour fonc tionner par des temp ratures lev es Pour ne pas se br ler pendant qu on intervient sur la pompe toujours la laisser refroidir pendant au moins 20 minutes apr s l avoir arr t e et avant de la manipuler CONSIGNES DE S CURIT CONCERNANT L LECTRICIT Cette pompe est livr e avec un cordon lectrique 3 conducteurs dont un d
14. pompe et la garantie sera annul e e P riodiquement inspecter la pompe le servor gulateur et les composants du systeme NOTA Les codes de la municipalit exigent peut tre l utilisa tion d une soupape de s ret ou d un r gulateur de pression ATTENTION Risque de fuite et d inondation Ne pas utiliser cette pompe si la pression d arriv e de l eau est sup rieure 345 kPa 50 lb po AVERTISSEMENT Pression dangereuse et risque d explosion Cette pompe peut d velopper des pressions extr mement lev es pendant qu elle fonctionne si son refoulement est ferm ou obstru Pour utiliser cette pompe en toute s curit nous recommandons de respecter ce qui suit Sur la tuyauterie de refoulement poser une soupape de s ret qui permettra d vacuer tout le d bit de la pompe une pres sion de 689 kPa 100 Ib po Amener le tuyau de refoulement branch sur la soupape de s ret jusqu un renvoi l gout de plancher ou jusqu tout autre renvoi l gout qui assurera une vacuation ad quate Figure Ne pas faire fonctionner la pompe si l arriv e est ferm e Prise de courant de 115 volts mise la terre et prot g e par un interrupteur de fuite la terre Vers l habitation refoulement de la pompe K 2 Soupape de s ret Raccords unions Clapet de non retour Alimentation en eau aspiration de la pompe Figure 2 Installation ty
15. pompe n est pas ad quatement amorc e Le filtre eau est bouch Le robinet de refoulement est ferm Le diam tre des tuyaux est trop petit L impulseur est bouch Les tuyaux sont gel s R amorcer la pompe conform ment aux instructions Arr ter la pompe Fermer l arriv e d eau et remplacer la cartouche filtrante Le filtre doit tre pos sur le c te refoulement de la pompe Ouvrir le robinet Remplacer les tuyaux par des tuyaux du m me diam tre que les orifices d aspiration et de refoulement de la pompe Nettoyer l impulseur Les d geler La pompe ne d bite pas son d bit maximal Les tuyaux rigides sont corrod s Le diam tre des tuyaux est trop petit La pompe n est pas suffisamment aliment e en eau Basse tension Les remplacer par des tuyaux rigides en plastique ou des tuyaux en acier neufs Remplacer les tuyaux par des tuyaux du m me diam tre que les orifices d aspiration et de refoulement de la pompe Utiliser un tuyau d arriv e d eau de diam tre plus gros v rifier le syst me de pompage du puits S assurer que la prise de courant est aliment e en courant alternatif de 115 volts Pour obtenir des pi ces ou de l aide appeler le Service la client le Simer en composant le 800 468 7867 1 800 546 7867 Pieces de rechange 16 4220 0702 S rie Ace In The Hole mod le 307558 D signation 307558 R f des pi ces Qt 1 2 ch 1
16. s lo zumba La tensi n es demasiado baja El impulsor no se est moviendo con libertad Verifique la tensi n de suministro a la bomba Verifique que el impulsor se est moviendo libremente y que no est obstruido El motor marcha pero no Cebadura inadecuada descarga agua Filtro de agua obstruido NOTA Desenchufe la bomba luego abra los grifos y observe si el agua corre a trav s del sistema V lvula de descarga cerrada Tuber a de tama o demasiado peque o El impulsor est obstruido Las tuber as est n congeladas Vuelva a cebar seg n las instrucciones Detenga la bomba cierre el suministro de agua y cambie el cartucho de filtro El filtro se debe instalar del lado de la descarga de la bomba Abra la v lvula Vuelva a conectar las tuber as usando una tuber a del mismo tama o que los orificios de aspiraci n y de descarga en la bomba Limpie el impulsor Descongele las tuber as La bomba no Tuber as corro das descarga agua a toda La tuber a es de un tama o demasiado su capacidad peque o No se suministra suficiente agua a la bomba Baja tensi n Reemplace con tuber as nuevas de pl stico r gido o de acero Vuelva a conectar las tuber as usando una tuber a r gida del mismo tama o que los orificios de aspiraci n y de descarga en la bomba Agrande la tuber a de admisi n inspeccione el sistema de la bomba de pozo Verifique que el tomacorriente sea de 115
17. todas las instrucciones de seguridad que aparecen en este manual y en el equipo Mantenga las etiquetas de seguridad en buen estado Cambie toda etiqueta de seguridad que falte o est da ada Aseg rese de que los talleres sean a prueba de ni os use candados e interruptores maestros retire las llaves de arranque encendido INSTRUCCIONES GENERALES sde SEGURIDAD Para evitar el riesgo de lesiones corporales graves y da os materiales lea con atenci n las instrucciones de seguridad antes de instalar esta bomba 2 Observe los c digos de plomer a construcci n y electrici dad tanto locales como nacionales cuando instale la bomba Use tubos r gidos cuando instale esta bomba 3 LA ADVERTENCIA Presi n peligrosa El cuerpo de la bomba puede explotar si sta se usa para reforzar presi n por encima de los 100 psi 689 kPa Instale una v lvula de desahogo de presi n en la l nea de descarga capaz de pasar el caudal total de la bomba a 100 psi 689 kPa Si esta disposici n est en conflicto con el c digo siga las instrucciones del c digo No use esta bomba con una pre si n de admisi n superior a 50 psi 345 kPa 4 Se recomienda instalar un interruptor de cierre de seguri dad por baja presi n para apagar la bomba en caso de una presi n de descarga baja debido a la interrupci n del sum inistro de agua entrante a una tuber a rota etc 5 Nunca deje marchar la bomba en seco Esto podr a da
18. voltios Si necesita repuestos o asistencia llame al Servicio al Cliente de Simer l 800 468 7867 1 800 546 7867 Repuestos para la reparaci n Modelo 3075SS de la Serie Ace in the hole La mejor baza Clave Descripci n 307588 No de la pieza Cantidad 1 2 HP 1 Juego de unidad de bomba incluye pernos 1 FPP1801 2 Juego de repuestos internos 1 FPP1870 3 Capacitor 1 171P5750 4 Juego de caja de cables Cubierta Empaquetadura 1 FPP1802 5 Rejilla de protecci n 1 72151090 6 Juego de sello del eje y aro t rico 1 FPP1850 24 4220 0702 Si necesita repuestos o asistencia llame al Servicio al Cliente de Simer 1 800 468 7867 1 800 546 7867
19. Corps de la pompe comprend les boulons 1 FPP1801 2 Trousse des pi ces internes 1 FPP1870 3 Condensateur 1 171P5750 4 Trousse de bo te de c blage Couvercle Joints 1 FPP1802 5 Carter du ventilateur 1 72151090 6 Trousse de joints d arbre et de joints toriques 1 FPP1850 Pour obtenir des pi ces ou de l aide appeler le Service la client le Simer en composant le 800 468 7867 1 800 546 7867 17 Pour obtenir des pi ces ou de l aide appeler le Service la client le Simer en composant le 800 468 7867 1 800 546 7867 Seguridad ES IMPORTANTE LEER Y SEGUIR LAS INSTRUCCIONES DE SEGURIDAD Este es el simbolo de alerta de seguridad Cuando vea este simbolo en su bomba o en este manual busque una de las siguientes palabras de se al y est alerta a la posibilidad de lesiones personales LN Advierte sobre peligros que provocar n lesiones personales graves muerte o da os materiales consider ables si se les ignora ADVERTENCIA Advierte sobre peligros que pueden provocar lesiones personales graves muerte o da os materiales consider ables si se les ignora PRECAUCI N Advierte sobre peligros que provocar n o pueden provocar lesiones personales o da os materiales menores si se les ignora La etiqueta de ATENCI N NOTICE indica instrucciones especiales que son importantes pero que no est n asociadas a peligros Lea y observe cuidadosamente
20. INICIAL y el flujo se haya detenido CU NDO DEJA DE FUNCIONAR LA BOMBA Punto de referencia de presi n sin flujo La bomba dejar de funcionar y la luz de BOMBA ENCENDIDA se apagar 15 segundos despu s de que e La presi n del sistema es superior al punto configurado en el cuadrante de PRESI N INICIAL y e El flujo se haya detenido Este es el funcionamiento normal Reinicio Un flujo de agua en el sistema mayor de 1 gpm o una ca da en la presi n por debajo del punto de referencia de la PRESI N INICIAL har que la bomba reinicie su ciclo y se encienda la luz de BOMBA ENCENDIDA La bomba continuar funcionando hasta 15 segundos despu s de que e haya alcanzado la presi n configurada y e el flujo se haya detenido NOTA La demora de 15 segundos de la bomba en apagarse evita la creaci n de un ciclo r pido cuando los grifos de agua se abren y cierran r pidamente por ejemplo cuando uno se lava los dientes etc Si necesita repuestos o asistencia llame al Servicio al Cliente de Simer 1 800 468 7867 1 800 546 7867 Operaci n Servicio Localizaci n de fallas Ca da de presi n Sin flujo Normalmente cuando la bomba inicia el bombeo r pidamente genera presi n y flujo Si no hay flujo y la presi n no sube detecta un estado de falta de agua Tambi n puede detectar esto durante el funcionamiento si falla el suministro de agua hacia la bomba Para proteger a la bomba y
21. NTROLLER The Automatic Pressure Controller mounts on the pump It protects against e Run dry operation e Overheating e Frequent starts caused by small water losses in the system e Pressure drop The Automatic Pressure Controller features the following LEDs and controls POWER ON LED indicates that the unit is electrically connected and that voltage is present The pump is ready to operate PUMP ON LED indicates that the pump is running and actually pumping water WATER FAILURE LED indicates that no water is detected coming into the pump TEMPERATURE FAILURE LED indicates that the tem perature inside the pump has reached 158 F 70 C Reset Water Failure LED _ Temp Failure LED ST Pump on LED Z Power on LED ie Starting Pressure Dial Figure 4 Control Panel Starting Pressure dial allows you to set the system pressure at 15 to 45 psi 103 to 310 kPa The pump will start automatically when the system pressure drops below the pressure point which you have set on the Starting Pressure dial Reset button resets any safeties which have tripped and allows the pump to restart NOTE The unit will not respond if the RESET button is held down It must be pressed and released to activate the reset function NORMAL OPERATION OF THE 3075SS CAUTION Burn Hazard NEVER run the pump dry Running the pump without water may cause pump to ove
22. Simer 293 Wright St Delavan WI 53115 Phone 1 800 468 7867 1 800 546 7867 Fax 1 800 390 5351 Web Site http www simerpump com OWNER S MANUAL Automatic Booster Pump mihe NOTICE D UTILISATION mihe Pompe de surpression fonctionnement automatique MANUAL DEL USUARIO Bomba autom tica de refuerzo mihe Installation Operation Parts For further operating installation or maintenance assistance Call 1 800 468 7867 English Pages 2 8 2002 PRINTED IN U S A Mod 3075SS Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 468 7867 Fran ais Pages 10 16 Instalaci n Operaci n Piezas Para mayor informaci n sobre el funcionamiento instalaci n o mantenimiento de la bomba Llame al 1 800 468 7867 Espa ol Paginas 18 24 SIM591 10 14 02 Safety READ AND FOLLOW SAFETY INSTRUCTIONS This is the safety alert symbol When you see this symbol on your pump or in this manual look for one of the following signal words and be alert to the potential for personal injury AA warns about hazards that will cause serious personal injury death or major property damage if ignored A WARNING warns about hazards that can cause serious personal injury death or major property damage if ignored CAUTION Warns about hazards that will or c
23. a bomba se cebe debidamente y puede reducir su rendimiento en forma considerable e El montaje de la bomba debe ser nivelado s lido tan cerca de la fuente de agua como sea posible y protegido contra el exceso de humedad y contra inundaciones e Use el trayecto m s corto posible para la tuber a y la menor cantidad posible de accesorios Trayectos de tuber a largos y numerosos accesorios aumentan la fricci n y reducen el flujo del agua e Apoye el peso de la tuber a y de la bomba e No permita que la bomba el controlador de presi n ni ning n componente del sistema se congelen El conge lamiento da ar la bomba y anular la garant a e Inspeccione peri dicamente la bomba el controlador de pre si n y los componentes del sistema NOTA El c digo local puede especificar el uso de una v lvula de desahogo de presi n o de un regulador de presi n PRECAUCI N Riesgo de fugas y de inundaci n No use esta bomba con una presi n de admisi n superior a 50 psi 345 kPa ADVERTENCIA Peligro de presi n y riesgo de explosi n Esta bomba puede desarrollar una presi n alta si se hace funcionar con la descarga cerrada u obstruida Para una operaci n segu ra recomendamos lo siguiente Instale una v lvula de desahogo de presi n en la l nea de descarga capaz de pasar el caudal total de la bomba a 100 psi 689 kPa Consulte la Figura 2 Si esta disposici n est en conflicto con el c d
24. an cause minor personal injury or property damage if ignored The label NOTICE indicates special instructions which are important but not related to hazards Carefully read and follow all safety instructions in this manual and on pump Keep safety labels in good condition Replace missing or damaged safety labels Make workshops childproof use padlocks and master switches remove starter keys GENERAL SAFETY 1 To avoid risk of serious bodily injury and property damage read the safety instructions carefully before installing this pump 2 Follow local and or national plumbing building and electrical codes when installing the pump Use rigid pipe when installing this pump 3 AWARNING Hazardous Pressure The pump body may explode if used to boost pressure above 100 psi 689 kPa Do not use this pump with inlet pressure greater than 50 psi 345 kPa If not already in the plumbing system install a pressure relief valve in the pump discharge line capable of passing the full pump flow at 100 psi 689 kPa If local code requires installation of a pressure relief valve capable of han dling the full pump flow at a pressure less than 100 psi 689 kPa follow the code requirements 4 A low pressure safety cutoff switch is recommended to shut off power to the pump in case of low dis charge pressure due to interruption of the incoming water supply broken pipe etc 5 Never run the pump dry To do so c
25. an damage inter nal parts overheat pump which can cause burns to people handling or servicing pump and will void warranty 2 6 AWARNING Risk of fire or explosion To avoid risk of fire and explosion Pump Water Only with this pump Do not pump flammable liquids or chemicals Do not use the pump near gas pilot lights or where chemical or gas fumes are present Use of an electric pump with liquids other than water or in an atmos phere containing chemical or gas fumes may ignite those liquids or gases and cause injury or death due to an explosion and or fire 7 A WARNING Burn Hazard If water is trapped in the pump during operation it may turn to steam Trapped steam can lead to an explosion and burns Never run the pump with the outlet closed or obstructed 8 A CAUTION Do not touch an operating motor Modern motors can operate at high temperatures To avoid burns when servicing the pump allow it to cool for 20 minutes after shut down before handling ELECTRICAL SAFETY A The pump is supplied with a 3 conductor ground ing type cord Connect only to a properly ground ed GFCI protected outlet Do not lift the pump by the electrical cord A WARNING Hazardous voltage Can shock burn or cause death Ground the pump before connecting to a power supply Disconnect the power before working on the pump motor or tank The pump and controller are non submersible Keep the motor dry a
26. ateur ne r pondra pas si la touche RESET R enclenchement est tenue appuy e Il faut appuy er sur cette touche puis la relacher pour actionner la fonction de r enclenchement FONCTIONNEMENT NORMAL DE LA POMPE PRESSUREMATE ATTENTION Risque de br lures Ne JAMAIS faire fonc tionner la pompe sec sinon elle risque de surchauffer et les personnes qui la manipuleront risqueront de se br ler L impulseur et le joint de l arbre de la pompe peuvent galement tre endommag s si la pompe fonctionne sec ce qui pourrait causer des fuites ou une inondation De plus la garantie sera annul e Avant de d marrer la pompe la remplir d eau S assurer que la pompe PressureMate a t ad quatement install e amorc e se reporter la page 11 que le tuyau d aspiration n est pas obstru et qu il est ouvert Tourner la manette rotative STARTING PRESSURE Pression de d marrage la pression minimum d sir e du syst me Brancher le cordon lectrique de la pompe dans la prise de courant Les t moins lectroluminescents POWER ON Sous tension et PUMP ON Pompe en marche s al lumeront indiquant respectivement que le courant lectrique alimente la pompe et que la pompe est pr te fonctionner La pompe d marrera et fonctionnera pendant 15 secondes apr s que la pression dans le syst me aura d pass la pression r gl e avec la manette rotative STARTING PRESSURE Pression
27. cesse de fonctionner e Le t moin lectroluminescent PUMP ON Pompe en marche s teint et Le t moin lectroluminescent PANNE DE TEMP RATURE clignote Red marrage Attendre 20 minutes pour laisser la temp ra ture de l eau chuter sous 40 C 104 F D PANNAGE I5 S assurer que la pompe est aliment e en eau et que le d bit n est pas obstru Appuyer sur la touche RESET R enclenchement puis la rel cher Le t moin lectroluminescent PUMP ON Pompe en marche doit s allumer et Le t moin lectroluminescent WATER FAILURE Manque d eau doit cesser de clignoter Sinon laisser refroidir la pompe plus longtemps puis r essayer NOTA Si la pompe continue de chauffer pendant qu elle fonctionne l arr ter et appeler le Service la client le Simer en composant le 1 800 468 7867 LUBRIFICATION Le moteur a t lubrifi l usine pour la dur e des paliers Le joint de l arbre de la pompe est lubrif et refroidi par l eau ENTRETIEN DE LA POMPE AVERTISSEMENT Tension dangereuse Risque de secousses lec triques de br lures voire de mort Avant d intervenir sur la pompe et le servor gulateur d brancher le cordon lectrique de la prise de courant Ne pas manipuler la pompe ni le servor gulateur et ne pas essayer d intervenir sur la pompe si on a les mains humides ou si l on se tient sur un plancher mouill ou humide Le mot
28. che e Serrer la main tous les raccords et tous les tuyaux branch s sur la pompe puis les serrer de 1 1 2 tour de plus au maximum e Un serrage excessif de ces raccords et de ces tuyaux risque de briser la pompe ce qui annulera la garantie e Le diam tre nominal minimum des tuyaux et des raccords branch s sur la pompe doit tre d au moins 1 pouce Des tuyaux et des raccords ayant un diam tre inf rieur 1 pouce diminueront le d bit ce qui risque d endommager la pompe suite une cavitation e S assurer qu il n y a pas de prises d air ni de poches d air dans le tuyau d aspiration Toute prise d air dans le tuyau d aspiration aspirera de l air sans toutefois que l eau coule par cette prise d air Toute prise d air et toute poche d air emp cheront la pompe de s amorcer ad quatement ce qui risquera de diminuer consid rablement son d bit e Le socle sur lequel la pompe sera pos e doit tre de niveau bien solide et aussi pr s que possible de la source d eau II doit galement tre prot g contre toute humidit et inonda tion excessives e Utiliser la plus courte longueur de tuyau possible et le moins possible de raccords De grandes longueurs de tuyau et de nombreux raccords augmentent le frottement ce qui diminue le d bit de la pompe e Supporter le poids de la tuyauterie et de la pompe e Ne pas permettre la pompe son servor gulateur ni aux composants de syst me de geler Le gel endommagera la
29. con conexi n a tierra Con ctela solamente a un toma corriente debidamente puesto a tierra y protegido por un GFCI disyuntor diferencial No levante la bomba por medio del cord n el ctrico ADVERTENCIA Tensi n peligrosa Puede provocar choque el ctrico quemaduras o muerte Conecte la bomba a tierra antes de conectarla a una fuente de suministro de energ a Desconecte la corriente antes de trabajar con la bomba con el motor o con el tanque La bomba y el controlador no son sumergibles Mantenga el motor seco en todo momento No lave el motor No lo sumerja Proteja el motor en situaciones de clima lluvioso Si usa un cord n de alargue use solamente un cord n trifilar aprobado para uso en el interior y al aire libre con conexi n a tierra No permita que ninguna parte del cord n o los extremos del recept culo queden apoyados en el agua o en lugares h medos Desenchufe la bomba antes de repararla o de realizar trabajos de mantenimiento Para evitar choques fatales proceda de la siguiente manera si es necesario reparar o realizar trabajos de mantenimiento en la bomba A Desconecte la corriente a la caja de salida de la bomba antes de desenchufarla Despu s de haberla desenchufado deje que la bomba se enfr e durante 20 minutos antes de tratar de trabajar en la misma B Proceda con extrema cautela cuando cambie los fusibles Para reducir la posibilidad de choques el ctricos fatal
30. difier par la suite au fur et mesure que l on acquerra de l exp rience avec le fonctionnement du syst me 13 Avant de poursuivre l installation et pour de plus amples d tails concernant les fonctions du syst me se reporter aux rubriques de cette notice intitul es Branchements lectriques Servor gulateur Fonctionnement normal de la pompe et Quand la pompe cesse t elle de fonctionner 14 ce point on peut brancher pour la premi re fois le cor don lectrique de la pompe dans la prise de courant Apr s avoir branch le cordon lectrique de la pompe dans la prise de courant la pompe d marrera et fonctionnera pendant 15 secondes quelle que soit la pression r gl e avec la manette rotative du servor gulateur Si la pression d arriv e est sup rieure la pression r gl e la pompe s ar r tera apr s 15 secondes 15 Pendant que la pompe fonctionne et apr s qu elle s arr te automatiquement le syst me fonctionne la pression r gl e Inspecter de nouveau les tuyaux et les raccords pour s assurer qu il n y a pas de fuites En cas de fuites d brancher le cordon lectrique de la pompe de la prise de courant fermer le robinet de la conduite d arriv e d eau principale puis ouvrir un robinet de l habitation pour dis siper la pression dans les tuyaux R parer la fuite R p ter cette op ration jusqu ce que le syst me soit compl te ment tanche qu il ne fuit plus
31. e mise la terre Ne brancher ce cordon lectrique que dans une prise de courant ad quate ment mise terre et prot g e par un disjoncteur de fuite la terre Ne pas lever cette pompe par son cordon lectrique AVERTISSEMENT Tension dangereuse Risque de secousses lectriques de br lures voire de mort Mettre cette pompe la terre avant de la brancher sur le courant lectrique Couper le courant avant d intervenir sur la pompe le moteur ou le r servoir Cette pompe et son servor gulateur ne sont pas sub mersibles Toujours garder le moteur sec Ne pas le laver Ne pas l immerger Le prot ger contre la pluie Si on doit utiliser un cordon prolongateur n utiliser qu un cordon prolongateur 3 conducteurs dont un de mise la terre et approuv pour l utilisation int rieure et ext rieure Ne permettre aucune partie du cordon prolonga teur ni sa fiche et sa prise de reposer dans l eau ou dans un endroit humide Avant d intervenir sur la pompe la d brancher de la prise de courant Pour viter de subir des secousses lec triques mortelles si on doit intervenir sur la pompe proc der comme il est indiqu ci dessous A Couper le courant alimentant la prise de courant avant d intervenir sur la pompe Apr s avoir d branch la fiche du cordon lectrique de la prise de courant attendre au moins 20 minutes avant d intervenir sur la pompe afin de la laisser refroidir
32. er with your 3075SS To avoid clogging the pump and damaging the shaft seal do not pump water containing solids foreign material sand silt or abrasives e If you are boosting the pressure from a well pump be sure that the system check valves are tight If the sys tem pressure drops when the well pump is not run ning the 307555 may start and cycle Excessive or rapid cycling may damage the motor and will void the warranty e Do not use pipe joint compound on pump ports use only teflon tape to seal the threads Pipe joint com pound will damage the controller materials NOTE The priming plug has an O ring already installed and does not require sealing e Tighten all the piping joints to the pump hand tight plus 1 1 2 turns not more Overtightening may break the pump and will void the warranty e Pipe and fittings to the pump should be at least nomi nal 1 diameter Pipe or fittings less than 1 in diame ter will reduce performance and may damage the pump through cavitation e Make sure that there are no air leaks or air pockets in the suction pipe An air leak in the suction pipe may draw air in although no water leaks out Air leaks and air pockets will prevent the pump from priming prop erly and can substantially reduce its performance e The pump mount should be level solid as near as possible to the water source and protected against excess moisture and flooding e Use the shortest possible run for pi
33. era instalar un interruptor de cierre de seguridad por baja presi n en la descarga de la bomba para apagar la corriente en caso de una baja presi n de descarga provo cada por una tuber a rota etc Instale la bomba sobre una base firme en el lugar que haya decidido Escoja un momento en que pueda cerrar el suministro de agua a la casa mientras instala la PressureMate Cierre la v lvula principal de suministro de agua a la casa Abra cualquier grifo para descargar la presi n del agua en la plomer a Una vez que haya descargado la presi n del agua cierre el grifo LEA COMPLETAMENTE EL PASO 6 ANTES DE COMENZAR A TRABAJAR EN LA BOMBA Usted debe sacar un largo de la tuber a de la l nea de suministro principal de agua para permitir la instalaci n de los codos para la PressureMate Los lugares de los cortes deben tener en cuenta el tama o de los codos que se est n usando el largo de las roscas en las juntas fileteadas o la superposici n en las juntas adheri das o soldadas etc Coloque los codos en l nea con las roscas de aspiraci n y descarga de la bomba Puede haber una peque a fuga de agua mientras est cortando la tuber a Saque las rebabas o virutas creadas por la her ramienta de corte NOTA Es posible que no se necesite cortar las tuber as gal vanizadas si hay una uni n cerca del lugar de la bomba desarme la uni n y saque destornille la tuber a hasta pasar el lugar de ubicaci n de la bomba Corte y e
34. es NO se pare sobre el agua ni ponga sus dedos en el porta fusibles C Conecte a tierra la caja el ctrica de salida D Enchufe la bomba y el controlador en un tomacorriente conectado a tierra y protegido por un Disyuntor Diferencial GFCI seg n sus siglas en ingl s Si necesita repuestos o asistencia llame al Servicio al Cliente de Simer 1 800 468 7867 1 800 546 7867 Indice 19 Gracias por comprar una bomba de alta calidad probada en la f brica Informaci n General sobre la Seguridad CA A ane tamerets Informaci n general Instalaci n 22 Conexi n el ctrica Controlador autom tico de presi n Operaci N oscila ae Cu ndo deja de funcionar la bomba SEVI CI Ori EET eee Localizaci n de fallas o oommmmm Repuestos para la reparaci n PR I aoe 22 23 Garantia limitada de Simer SIMER garantiza al comprador consumidor original Comprador de sus produc tos que se encuentran libres de defectos en material o mano de obra Si dentro de los doce 12 meses a partir de la fecha de la compra original por el con sumidor ese producto resulta defectuoso ste ser reparado o reemplazado a opci n de SIMER sujeto a los t rminos y condiciones mencionados a continuaci n Su recibo de compra se usar para determinar la elegibilidad de la garant a Excepciones a la Garant a de doce 12 meses Garan
35. eur est dot d un limiteur de surcharge r enclenche ment automatique Si le moteur surchauffe le limiteur de sur charge interrompra le courant lectrique alimentant la pompe pour emp cher qu elle soit endommag e le limiteur de sur charge se r enclenchera automatiquement d s que le moteur aura refroidi Si le limiteur de surcharge se d clenche de fa on r p titive v rifier la pompe et d terminer la cause de cet inci dent basse tension impulseur bouch etc SYMPT MES CAUSES POSSIBLES MESURES CORRECTIVES Le moteur ne d marre pas Le fusible est saut ou le disjoncteur est disjonct Le cordon lectrique n est pas branch dans une prise de courant COUPER LE COURANT Remplacer le fusible ou r enclencher le disjoncteur Brancher le cordon lectrique dans une prise de courant mise la terre aliment e en courant alternatif de 115 volts Le moteur chauffe et le limiteur de surcharge se d clenche ou bien le moteur ne fonctionne pas et ne fait que murmurer La tension est trop basse L impulseur ne tourne pas librement V rifier la tension alimentant la pompe V rifier l impulseur pour s assurer qu il tourne librement et qu il n est pas bouch Le moteur fonctionne mais la pompe ne d bite pas d eau Nota D brancher le cordon lectrique de la pompe de la prise de courant puis ouvrir un robinet pour confirmer que l eau circule dans le systeme La
36. ga por debajo del punto de presi n configurado en el cuad rante de Presi n inicial El bot n de Reposici n reposiciona todos los medios de seguridad que se hayan disparado y permite que la bomba se vuelva a encender NOTA La unidad no responder si se mantiene oprimido el bot n de REPOSICI N Se debe oprimir y soltar para activar la funci n de reposici n FUNCIONAMIENTO NORMAL DE LA PRESSUREMATE PRECAUCI N Peligro de quemaduras NUNCA deje mar char la bomba en seco Si se deja que la bomba marche sin agua sta se podr recalentar y podr quemar a las personas que est n manipulando la bomba Tambi n podr da ar el impulsor y el sello provocando fugas o inundaci n y anular la garant a Llene la bomba con agua antes de encenderla Verifique que la PressureMate se haya instalado y cebado debidamente Consulte la P gina 4 y que la tuber a de aspiraci n no est obstruida y est abierta Haga girar el cuadrante de PRESI N INICIAL a la presi n m nima del sistema que se desee Enchufe la bomba Se encender n las luces de CORRIENTE ACTIVADA y BOMBA ENCENDIDA indicando respectiva mente que hay tensi n el ctrica y que la bomba est lista para funcionar La bomba comenzar a funcionar y continuar funcionando hasta 15 segundos despu s de que la presi n del sistema se haya elevado m s all del punto de referencia en el cuadrante de PRESI N
37. igo siga las instrucciones del c digo Deje que la descarga de la v lvula de desahogo vaya hacia un desag e del piso o a otro desag e que permita una eliminaci n adecuada Figura No deje marchar la bomba con la admisi n cerrada Tomacorriente de 115V conectado a tierra y protegido por un GFCI A la casa descarga de la bomba V lvula de desahogo Uniones V lvula checadora Admisi n del suministro de agua aspiraci n de la bomba Figura 2 Instalaci n t pica de refuerzo en un entorno dom stico Adquiera los accesorios de plomer a por separado Consulte el c digo con los requerimientos para la v lvula de desahogo y el regulador de presi n INSTALACI N PRECAUCI N Riesgo de inundaci n Verifique que toda la plomer a y los accesorios est n clasificados para resistir la presi n del sistema que se espera que genere la bomba 1 Decida cu l es el mejor lugar para instalar la bomba Tenga en cuenta lo siguiente e debe estar cerca de la l nea principal de suministro de agua e la bomba debe ser accesible e el cord n el ctrico debe llegar hasta un tomacorriente e las luces DEL del controlador deben ser visibles e facilidad de plomer a e ahorro de espacio Si necesita repuestos o asistencia llame al Servicio al Cliente de Simer 1 800 468 7867 1 800 546 7867 Instalaci n 9 NOTA Se recomienda y es posible que su c digo local as lo requi
38. ing turned on and off quickly for example when brushing teeth etc For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867 Operation Service Troubleshooting Pressure Drop No Flow Normally when the pump starts it will very quickly generate pressure and sense flow If there is no flow and the pressure does not rise it senses a no water condition lt can also sense this dur ing operation if the water supply to the pump fails To protect the pump from running dry e 15 seconds after it detects no water the pump will stop operating e The PUMP ON LED will go out and e The WATER FAILURE LED will begin flashing Restart Make sure that the suction line is not obstruct ed and that it is connected to a water source e Press and release the RESET button e The PUMP ON LED should light up and e The WATER FAILURE LED should stop flashing If flow is adequate the pump will operate until it reaches the set point pressure and the flow stops High Temperature When the water temperature inside the pump reaches 158 F 70 C e The pump will stop operating e The PUMP ON LED will go out and e The TEMPERATURE FAILURE LED will begin flashing Restart Wait 20 minutes to let the water temperature drop below 104 F 40 C e Make sure that the pump is supplied with water and that the flow is unobstructed TROUBLESHOOTING
39. must take into consideration the size of the elbows being used the length of the threads in threaded joints or the overlap in glued or soldered joints etc Position the elbows in line with the pump suction and discharge threads There may be slight water leakage while cutting the pipe Remove any burrs or shavings caused by the cutting tool NOTE Galvanized pipe may not need to be cut If there is a union close to the pump location disas semble the union and remove unscrew pipe back past the pump location Have new lengths of pipe cut and threaded to allow for the pump installation NOTE Both female suction and male discharge ports have 1 NPT threads Depending on your type of connection and the size of your home s piping you may need to install adapters on the ports Once the short piece of pipe is removed the piping above the cut can be drained to prevent water mess Place a pail under the opening going to the house hold Open the highest faucet in the system to let in air so the water can fall out of the pipes into the pail Once it s drained close the faucet Install the elbows in the main water supply line Point them toward the pump WARNING Risk of burst hose and flooding Do not install with flexible hoses Use only rigid piping that meets code Install piping from elbows to pump including a union in each line and a check valve in the pump suction line The arrow on the check valve must point to
40. nrosque nuevos largos de tuber a para permitir la instalaci n de la bomba NOTA Tanto los orificios hembra de aspiraci n como los orificios macho de descarga tienen roscas NPT de 1 pulga da Seg n el tipo de conexi n que usted tenga y el tama o de la tuber a de su casa es posible que deba instalar adap tadores en los orificios Una vez que haya sacado un trozo peque o de tuber a podr drenar la tuber a que se encuentre por encima del corte para evitar que el agua ensucie el rea Coloque un balde debajo de la abertura que conduce hacia la casa Abre el grifo m s alto en el sistema para dejar entrar el aire de manera que el agua pueda caer y salir de las tuber as hacia el balde Una vez que haya drenado cierre el grifo Instale los codos en la l nea de suministro principal de agua Ap ntelos hacia la bomba ADVERTENCIA Riesgo de explosi n de la manguera y de inundaci n No haga la instalaci n con mangueras flexibles Use solamente tubos r gidos que cumplan con las disposi ciones del c digo Instale la tuber a desde los codos a la bomba incluyendo una uni n en cada l nea y una v lvula checadora en la l nea de aspiraci n de la bomba La flecha en la v lvula checadora debe apuntar hacia la aspiraci n de la bomba consulte la Figura 2 Instale una v lvula de desahogo de presi n en la l nea de descarga capaz de pasar el caudal total de la bomba a 100 psi 689 kPa Si esta disposici n es
41. o enchufe el cord n el ctrico la bomba se encen der y marchar por unos 15 segundos independiente mente de la graduaci n del controlador Si la presi n de admisi n es superior al punto de referencia la bomba se detendr despu s de 15 segundos Cuando la bomba marche y despu s se apague autom tica mente el sistema estar a las presiones reforzadas Inspeccione la tuber a y los accesorios nuevamente para verificar que no haya fugas Si aparecen fugas desenchufe la bomba cierre la v lvula principal de suministro de agua abra un grifo para descargar la presi n y repare la fuga Repita este paso hasta que no haya m s fugas en el sistema A la casa Admisi n del suministro de agua Figura 3 Tuber a t pica de desviaci n que se necesita para permitir la remoci n de la bomba para repara ciones sin cerrar el sistema de agua dom stico Si necesita repuestos o asistencia llame al Servicio al Cliente de Simer 1 800 468 7867 1 800 546 7867 Instalaci n Operaci n CONEXIONES EL CTRICAS ADVERTENCIA Riesgo de choque el ctrico peligroso o fatal Enchufe la bomba solamente en un tomacorriente de 115 voltios 60 ciclos conectado a tierra y protegido por un Disyuntor Diferencial GFCI seg n sus siglas en ingl s La bomba viene equipada con un cord n el ctrico trifilar y un enchufe conectados a tierra No modifique ni saque el enchufe Aseg rese de que el tomacorriente cumpla con las n
42. odo de la garant a Esta garant a establece la nica obligaci n de SIMER y el recurso exclusivo del comprador en relaci n a productos defectuosos SIMER NO SE HAR RESPONSABLE DE NING N DA O CONSECUENTE INCI DENTAL O CONTINGENTE LAS GARANT AS QUE ANTECEDEN SON EXCLUSIVAS Y EN LUGAR DE TODA OTRA GARANT A EXPL CITA O IMPL CITA INCLUYENDO PERO SIN LIMITARSE A LAS GARANT AS IMPL CITAS DE COMERCIABILIDAD E IDONEIDAD PARA UN FIN ESPEC FICO Y NO SE EXTENDER N M S ALL DE LA DURACI N DE LAS GARANT AS EXPL CITAS CORRESPONDIENTES SUMINISTRADAS EN LA PRESENTE Algunos estados no permiten la exclusi n o limitaci n de da os incidentales o consecuentes o de limitaciones de tiempo sobre garant as impl citas de modo que es posible que las limitaciones o exclusiones que preceden no correspondan en su caso Esta garant a le otorga derechos legales espec ficos y es posible que Ud tambi n tenga otros derechos que pueden variar de un estado al otro SIMER 293 Wright St Delavan WI E U A 53115 Tel fono 1 800 468 7867 1 800 546 7867 Fax 1 800 390 5351 Si necesita repuestos o asistencia llame al Servicio al Cliente de Simer 1 800 468 7867 1 800 546 7867 Informaci n general Instalaci n 20 Use PressureMate para reforzar la presi n del agua de servicio municipal Las conexiones de plomer a se describen en este manual INFORMACI N GENERAL Bombee solamente agua limpia con su PressureMate Pa
43. ormas del National Electric Code o del Canadian Electrical Code seg n cor responda Para evitar el peligro de choque el ctrico mantenga el cord n seco en todo momento Consulte la Figura 2 CONTROLADOR AUTOM TICO DE PRESION El Controlador Autom tico de Presi n se monta sobre la bomba y la protege contra e funcionamiento en seco e recalentamiento e arranques frecuentes provocados por p rdidas peque as de agua en el sistema e ca da de presi n El Controlador Autom tico de Presi n tiene las luces DEL diodo emisor de luz y los controles siguientes Luz de Corriente activada indica que la unidad est conecta da el ctricamente y que hay tensi n el ctrica La bomba est lista para funcionar Luz de Bomba encendida indica que la bomba est marchando y bombeando agua Luz de Falla de agua indica que no se detecta agua desde la bomba Reposici n Luz de falla de agua Luz de falla de temperatura 4 Luz de bomba encendida Luz de corriente L activada Cuadrante de presi n inicial Figura 4 Tablero de control de PressureMate 22 Luz de Falla de temperatura indica que la temperatura den tro de la bomba ha alcanzado los 158 F 70 C El cuadrante de Presi n inicial le permite graduar la presi n del sistema entre 15 y 45 psi 103 y 310 kPa La bomba se encender autom ticamente cuando la presi n del sistema cai
44. ormation on how the system functions 14 At this point you can plug in the pump for the first time When you plug in the power cord the pump will start and run for 15 seconds regardless of the controller setting If the inlet pressure is above the set point the pump will stop after 15 seconds 15 When the pump is running and after it shuts off auto matically the system is at the boosted pressures Inspect the pipe and fittings again for water leaks If any leaks appear unplug the pump turn the water main valve off open a faucet to relieve the pressure and repair the leak Repeat this step until there are no leaks in the system To Household RS Water Supply In Figure 3 Typical bypass piping needed to allow removal of pump for repair without shutting down household water system For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867 Installation Operation ELECTRICAL CONNECTION WARNING Hazardous voltage Risk of dangerous or fatal electric shock Plug the pump into a 115 Volt 60 Cycle Ground Fault Circuit Interrupter GFCI protect ed grounded outlet only The pump is equipped with a 3 wire grounded cord and plug Do not modify or remove the plug Make sure the outlet meets the National Electric Code or the Canadian Electrical Code as applicable To avoid dangerous electrical shock haz ard keep the cord dry at all times See Figure 2 AUTOMATIC PRESSURE CO
45. pape de s ret qui permettra d vacuer tout le d bit de la pompe une pression de 689 kPa 100 Ib po Si cette stipulation est contraire aux codes respecter les codes Un disjonc teur de s curit doit galement install sur la conduite de refoulement au cas o la pression de refoulement de la pompe chuterait Les codes de la municipalit peuvent aussi exiger l utilisation d un tel disjoncteur de s curit 10 Une fois les tuyaux et les raccords install s et rendus 13 tanches ouvrir le robinet de la conduite d arriv e d eau principale de fa on mettre sous pression le syst me et pouvoir v rifier son tanch it Si on remarque des fuites fermer le robinet de la conduite d arriv e d eau principale ouvrir un robinet de l habitation pour dissiper la pression dans les tuyaux puis r parer la fuite R p ter cette op ra tion jusqu ce que le syst me soit compl tement tanche qu il ne fuit plus 11 Ouvrir un robinet pour chasser l air des tuyaux et permettre l eau de couler D s que l eau coulera normalement du robinet la pompe sera pleine d eau et compl tement amor c e Fermer le robinet 12 Tourner la manette rotative du servor gulateur sur la pres sion laquelle on d sire que la pompe se mette en marche La pompe PressureMate est livr e r gl e 207 kPa 30 lb po Au d but il est recommand de faire fonctionner la pompe sur ce r glage puis de le mo
46. pe d une pompe de surpression dans une habitation Les raccords des tuyaux doivent tre achet s s par ment Consulter les codes pour savoir quelle soupape de s ret lquel r gulateur de pression doivent tre utilis s INSTALLATION ATTENTION Risque d inondation S assurer que tous les tuyaux et que tous les raccords utilis s sont certifi s pour sup porter les pressions que la pompe du syst me peut produire 1 D cider du meilleur emplacement pour installer la pompe Dans cette optique il faudra consid rer ce qui suit e La pompe doit tre pos e le plus pr s possible de la conduite principale d arriv e d eau e On doit pouvoir acc der facilement la pompe e Une prise de courant doit tre assez proche pour que le cordon puisse y tre branch e Les t moins lectroluminescents du servor gulateur doivent tre visibles e On doit pouvoir facilement brancher la tuyauterie sur la pompe e La pompe doit prendre le moins de place possible Pour obtenir des pi ces ou de l aide appeler le Service la client le Simer en composant le 800 468 7867 1 800 546 7867 Installation NOTA II est recommand et cette recommandation peut tre exig e par les codes de la municipalit de poser un disjoncteur de s curit au cas o la pression c t refoule ment de la pompe chuterait suite un tuyau cass etc afin que le courant alimentant la pompe soit coup Monter la pompe s
47. ping and the smallest possible number of fittings Long pipe runs and numerous fittings increase friction and reduce the flow of water e Support the weight of the piping and pump e Do not allow the pump pressure controller or any system components to freeze Freezing will damage the pump and void the warranty e Periodically inspect the pump pressure controller and system components NOTE Local code may require a pressure relief valve or pressure regulator CAUTION Risk of leaks and flooding Do not use this pump with inlet pressure greater than 50 psi 345 kPa WARNING Pressure hazard and risk of explosion This pump can develop high pressure when operated with the discharge shut off or obstructed For safe operation we recommend the following If not already in the plumbing system install a pressure relief valve in the pump discharge line capable of pass ing the full pump flow at 100 psi 689 kPa See Figure 2 If local code requires installation of a pressure relief valve capable of handling the full pump flow at a pres sure less than 100 psi 689 kPa follow the code require ments Run the relief valve discharge to a floor drain or other drain that will give adequate runoff Figure Do Not Run the Pump With Inlet Shut Off Grounded GFCI protected 115V g To Household Pump Discharge F4 Check Valve Water Supply In Pump Suction Figure 2 Typical household boo
48. r Purchaser of its products that they are free from defects in material or workmanship If within twelve 12 months from the date of the original consumer purchase any such product shall prove to be defective it shall be repaired or replaced at SIMER s option subject to the terms and conditions set forth below Your origi nal receipt of purchase is required to determine warranty eligibility Exceptions to the Twelve 12 Month Warranty Three 3 Year Warranty If within three 3 years from original consumer purchase any 3075SS shall prove to be defective it shall be repaired or replaced at SIMER s option subject to the terms and conditions set forth below General Terms and Conditions Purchaser must pay all labor and shipping charges necessary to replace product covered by this warranty This warranty shall not apply to acts of God nor shall it apply to products which in the sole judgement of SIMER have been subject to negligence abuse accident misapplication tampering alteration nor due to improper installation operation maintenance or storage nor to other than normal application use or service including but not limited to operational fail ures caused by corrosion rust or other foreign materials in the system or oper ation at pressures in excess of recommended maximums Requests for service under this warranty shall be made by returning the defec tive product to the Retail outlet or to SIMER as soon as possible
49. ra evitar obstruir la bomba y da ar el sello del eje no bombee agua que contenga part culas s lidas materiales extra os arena limo o sustancias abrasivas e Si est reforzando la presi n de una bomba de pozo veri fique que las v lvulas checadoras del sistema est n bien ajustadas Si cae la presi n del sistema cuando la bomba de pozo no est marchando la PressureMate puede encenderse y comenzar el ciclo Un ciclo excesivo o r pido puede da ar el motor y anular la garant a e No use compuestos para juntas de tuber as en los orificios de la bomba use solamente cinta de tefl n para sellar las roscas El compuesto para juntas de tuber as da ar los materiales del controlador NOTA El tap n de cebadura ya tiene un aro t rico instalado y no es necesario sellarlo e Ajuste a mano todas las juntas de las tuber as a la bomba m s 1 1 2 vueltas no m s Si ajusta demasiado puede romper la bomba y se anular la garant a e Las tuber as y los accesorios a la bomba deben ser por lo menos de 1 pulgada de di metro nominal Las tuber as o los accesorios menores de 1 pulgada de di metro reducir n el rendimiento y pueden da ar la bomba debido a la cav itaci n e Verifique que no hayan fugas de aire ni bolsas de aire en la tuber a de aspiraci n Una fuga de aire en la tuber a de aspiraci n puede hacer penetrar aire aunque no se observen fugas de agua Las fugas de aire y las bolsas de aire evitar n que l
50. rheat and cause burns to persons handling the pump It may also damage the impeller and may damage the seal causing leaking or flooding and will void the war ranty Fill the pump with water before starting it Make sure that the 3075SS has been properly installed primed see page 4 and that the suction pipe is unob structed and open Turn the STARTING PRESSURE dial to the minimum desired system pressure Plug in the pump The POWER ON and PUMP ON lights will come on indicating respectively that voltage is present and that the pump is ready to operate The pump will start and will continue to operate until 15 seconds after the system pressure has risen past the set point on the STARTING PRESSURE dial and flow has stopped WHEN DOES THE PUMP STOP OPERATING Pressure Set Point No Flow The pump will stop operat ing and the PUMP ON LED will go off 15 seconds after e The system pressure is above the point set by the STARTING PRESSURE dial and e The flow has stopped This is normal operation Restart A water flow in the system greater than 1 GPM or a drop in pressure below the STARTING PRESSURE set point will cause the pump to restart and the PUMP ON LED to light up The pump will contin ue to operate until 15 seconds after e lt reaches the set pressure and e The flow stops NOTE The 15 second delay in shutting off the pump prevents rapid cycling when water faucets are be
51. sera pos e Couper de nou velles longueurs de tuyau et les fileter de fa on permettre l installation de la pompe NOTA Les orifices d aspiration femelle et de refoulement m le de la pompe ont 1 pouce NPT de diam tre et ils sont filet s En fonction du type des raccordements et du diam tre des tuyaux de l habitation il faudra peut tre poser des adaptateurs dans ces orifices Apr s avoir d pos la petite longueur de tuyau on pourra vider la tuyauterie au dessus de la coupe de fa on ne pas causer de d g ts d eau Mettre un seau sous le tuyau coup alimentant l habitation Ouvrir le robin et se trouvant le plus haut et laisser l air s introduire dans les tuyaux pour que l eau coule dans le seau Lorsque les tuyaux seront vides fermer le robinet Installer les coudes sur la conduite d arriv e d eau princi pale en les orientant vers la pompe AVERTISSEMENT Des tuyaux souples risquent d clater et de causer une inondation ne faut donc pas utiliser de tuyaux souples pour proc der cette installation N utiliser que des tuyaux rigides conformes aux codes Brancher les tuyaux sur les coudes jusqu la pompe en utilisant un raccord union sur chaque conduite et un clapet de non retour sur la conduite d aspiration de la pompe La fl che frapp e sur le clapet de non retour doit tre orient e vers l aspiration de la pompe se reporter la Figure 2 Sur la conduite de refoulement poser une sou
52. ster installation Purchase plumbing fittings separately Consult code for relief valvelpressure regulator requirements INSTALLATION CAUTION Risk of flooding Be sure that all plumbing and fittings are rated to withstand the system pressure which you expect the pump to generate 1 Decide what s the best place to install the pump Think about these things e it must be near the main water supply line the pump must be accessible the power cord must reach a power outlet the controller s LED lights must be visible ease of plumbing space saving For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867 Installation NOTE Installation of a low pressure safety cutoff switch on the pump discharge is recommended and may be required by your local code to shut off the power in case of low discharge pressure caused by broken pipe etc Mount the pump on a solid base in the location you have decided on Choose a time that will allow you to shut off the water to the household while you install the 307555 4 Shutoff the main water supply valve to the household Open any faucet to relieve water pressure in the plumbing Once the water pressure is relieved close the faucet READ STEP 6 COMPLETELY BEFORE STARTING TO WORK ON IT You must remove a length of pipe from the main water supply line to allow installation of elbows for the 307555 The locations of the cuts
53. t en conflicto con el c digo siga las instrucciones del c digo Tambi n se deber a instalar un interruptor de cierre de seguridad por baja presi n en la l nea de descarga que puede ser exigido por sus c digos locales 10 11 12 13 14 15 21 Con todas las tuber as y los accesorios instalados y sellados herm ticamente abra lentamente el suministro principal de agua para presurizar el sistema y verificar que no haya fugas Si aparecen fugas cierre la v lvula principal abra un grifo para descargar la presi n y reparar la fuga Repita este paso hasta que ya no haya fugas en el sistema Abra un grifo para descargar el aire de las tuber as y dejar que corra el agua Cuando observe que sale un chorro firme de agua del grifo la bomba estar llena de agua y completamente cebada Cierre el grifo Haga girar la perilla del controlador a la presi n en que desea que la bomba se encienda La PressureMate viene graduada de f brica a 30 psi 207 kPa y le recomendamos que comience a esa presi n y luego la ajuste seg n su experiencia con el sistema Antes de continuar con la instalaci n consulte las sec ciones de este manual tituladas Conexiones El ctricas Controlador Autom tico de Presi n Funcionamiento normal y Cu ndo deja de funcionar la bomba para obtener informaci n detallada sobre c mo funciona el sis tema Ahora usted puede enchufar la bomba por primera vez Cuand
54. t a de tres 3 a os Si dentro de los tres 3 a os de la compra por parte del comprador inicial se comprueba que un producto 3075SS es defectuoso ste ser reparado o reem plazado a opci n de SIMER sujeto a los t rminos y condiciones indicados a continuaci n T rminos y Condiciones Generales El comprador deber pagar por toda la mano de obra y cargos de env o necesar ios para reemplazar el producto cubierto por esta garant a Esta garant a no cor responde en caso de actos fortuitos ni corresponde a productos que a solo juicio de SIMER hayan sido objeto de negligencia abuso accidente mala aplicaci n alteraciones forzosas o de otro tipo ni debido a instalaci n operaci n manten imiento o almacenamiento indebidos ni debido a toda operaci n uso o servicio que no sea normal incluyendo pero sin limitarse a fallas de operaci n ocasion adas por corrosi n herrumbre u otros materiales for neos en el sistema o por la operaci n a presiones en exceso a los m ximos que se recomiendan Las solicitudes de servicio bajo esta garant a se deber n realizar por medio de la devoluci n del producto defectuoso a la tienda minorista o a SIMER a la brevedad posible despu s de haber descubierto el supuesto defecto SIMER entonces tomar una acci n correctiva tan pronto como sea razonablemente posible No se acep tar n solicitudes de servicio bajo esta garant a si se reciben despu s de m s de 30 d as de terminado el per
55. t all times Do not wash the motor Do not immerse Protect the motor from wet weather If using an extension cord use only an approved indoor outdoor 3 wire grounding type cord Do not allow any part of the cord or the receptacle ends to sit in water or in damp locations Unplug the pump before servicing To avoid fatal shock proceed as follows if the pump needs servicing A Disconnect the power to the pump outlet box before unplugging the pump After the plug is pulled let the pump cool for 20 minutes before attempting to work on it B Take extreme care when changing fuses To reduce the chance of fatal electrical shock DO NOT stand in water or put your finger in the fuse socket P Ground the electrical outlet box D Plug the pump and the controller into a Ground Fault Circuit Interrupter GFCI protected grounded outlet only For parts or assistance call Simer Customer Service at 800 468 7867 1 800 546 7867 Table of Contents Thank you for purchasing a top quality factory tested pump General Saeta ist Warranty ars TE General Information Installation ococccccccnncnnncnnnnnnnnnninininas Electrical Connection Automatic Pressure Controller Operation msi cido When Does Pump Stop Operating A A A etes Troubleshooting sus tre Repair Parts siennes sd has a Le 6 7 Simer Limited Warranty SIMER warrants to the original consumer purchase
56. t d origine sera remplac ou r par la discr tion de SIMER selon les con ditions stipul es ci dessous La preuve dat e de l achat servira d terminer si le produit est sous garantie Exceptions la garantie de douze 12 mois Garantie de trois 3 ans Si dans les trois 3 ans compter de la date d achat par l acheteur utilisateur initial n importe quel mod le 3075SS s av rait d fectueux il sera r par ou remplac au choix de SIMER conform ment aux conditions g n rales stipul es ci dessous Conditions g n rales L Acheteur s engage payer tous les frais de main d oeuvre et d exp dition n ces saires au remplacement du produit couvert par la garantie Cette garantie ne cou vre pas les cas de force majeure et ne s applique pas aux produits qui du seul avis de SIMER ont fait l objet de n gligence d utilisation abusive ou incorrecte d ac cident de modification ou d alt ration ni aux produits qui n ont pas t install s utilis s entrepos s ou entretenus correctement ni ceux qui n ont pas t utilis s ou entretenus normalement y compris mais sans s y limiter aux produits ayant subi des pannes de fonctionnement caus es par la corrosion la rouille ou tout autre corps tranger qui se serait introduit dans le syst me ou aux produits ayant fonctionn des pressions d passant la pression maximum recommand e Les demandes de service en vertu de la pr sente garantie seront fai
57. tes en retour nant le produit d fectueux au d taillant ou SIMER d s la d couverte du d faut all gu SIMER prendra alors les mesures correctives aussi rapidement qu il est raisonnablement possible Aucune demande de service en vertu de la pr sente garantie ne sera accept e si elle est re ue plus de 30 jours apr s l expiration de ladite garantie La pr sente garantie nonce la totalit des obligations de SIMER et le seul recours possible de l Acheteur dans le cas de produits d fectueux SIMER NE PEUT TRE TENUE RESPONSABLE D AUCUN DOMMAGE INDIRECT ACCIDENTEL OU FORTUIT QUEL QU IL SOIT LES PR SENTES GARANTIES SONT EXCLUSIVES ET TIENNENT LIEU DE TOUTE AUTRE GARANTIE EXPRESSE LES GARANTIES IMPLICITES Y COMPRIS MAIS SANS S Y LIMITER LES GARANTIES IMPLICITES AYANT TRAIT LA COMMERCIABILIT ET L ADAPTATION UN USAGE PARTICULIER NE D PASSERONT PAS LA DUR E DES GARANTIES EXPRESSE APPLICABLES STIPUL ES DANS LES PR SENTES Certaines provinces n autorisent pas d exclure ou de limiter des dommages fortu its ou indirects ou de limiter la dur e d une garantie implicite il se peut donc que les limitations ou exclusions ci dessus ne s appliquent pas votre cas La pr sente garantie vous donne des droits juridiques sp cifiques et vous pouvez en avoir d autres qui varient d une province l autre SIMER 293 Wright St Delavan WI 53115 T l 1 800 468 7867 1 800 546 7867 e T l c 1 800 390 5351
58. the pump suction see Figure 2 If not already in the plumbing system install a pressure relief valve in the pump discharge line capable of passing the full pump flow at 100 psi 689 kPa If local code requires installation of a pressure relief valve capable of han dling the full pump flow at a pressure less than 100 psi 689 kPa follow the code requirements A low pressure safety cutoff switch should also be installed in the discharge line and may be required by your local codes 5 10 With all pipe and fittings installed and sealed turn on the main water supply slowly to pressurize the system and check for leaks If any leaks appear turn the main valve off open a faucet to relieve the pressure and repair the leak Repeat this step until there are no leaks in the system 11 Open a faucet to release the air from the pipes and allow water to flow When a steady stream of water flows out of the faucet the pump is full of water and fully primed Close the faucet 12 Turn the controller knob to the desired pressure for the pump to turn on The 3075SS comes factory pre set at 30 psi 207 kPa and we recommend starting there and adjusting it later according to your experi ence with the system 13 Before continuing with the installation see the sections of this manual titled Electrical Connections Automatic Pressure Controller Normal Operation and When Does The Pump Stop Operating for detailed inf
59. tin a calent ndose durante el fun cionamiento ap guela y llame al Servicio de Atenci n al Cliente de Simer 1 800 468 7867 LUBRICACI N El motor viene lubricado de f brica para la vida til de los cojinetes El sello de la bomba se enfr a por agua y es auto lubricante SERVICIO DE LA BOMBA ADVERTENCIA Tensi n peligrosa Puede provocar choques quemaduras o muerte Desenchufe la bomba y el controlador antes de realizar trabajos de reparaci n o mantenimiento en los mismos No maneje la bomba ni el controlador ni trate de tra bajar en la bomba con manos mojadas o cuando est parado sobre un piso mojado o h medo El motor tiene un protector de sobrecarga t rmico que se reposi ciona autom ticamente Si se recalienta el motor el protector de sobrecarga cortar la corriente para evitar da os y se reposi cionar despu s de que el motor se haya enfriado Si el protec tor de sobrecarga se dispara repetidamente inspeccione la bomba para determinar la causa baja tensi n impulsor obstrui do etc S NTOMA CAUSA S POSIBLE S MEDIDA CORRECTIVA El motor no funciona El fusible est quemado o se dispar el disyuntor El cord n el ctrico no est enchufado DESCONECTE LA CORRIENTE Cambie el fusible o reposicione el disyuntor Enchufe en un tomacorriente de 115 voltios conectado a tierra El motor marcha en caliente y el protector de sobrecarga se dispara o el motor no marcha y
60. ur un socle solide l endroit que l on a choisi Choisir un moment dans la journ e qui permettra de couper l arriv e d eau alimentant l habitation pendant que l on proc dera l installation de la pompe PressureMate Fermer le robinet de la conduite d arriv e d eau principale de l habitation Ouvrir n importe quel robinet de fa on dissiper la pres sion d eau dans les tuyaux D s que la pression de l eau dans les tuyaux sera dissip e fermer le robinet AVANT DE POURSUIVRE LIRE ATTENTIVEMENT TOUTE L OP RATION 6 Pour permettre le branchement de la pompe PressureMate l aide de coudes il faudra couper une certaine longueur de la conduite d arriv e d eau princi pale Pour choisir l emplacement des coupes effectuer il faudra prendre en consid ration la dimension des coudes qu on utilisera la longueur du filetage des raccords ou l em boitement des raccords lisses coller ou souder etc Positionner les coudes en ligne avec les orifices d aspiration et de refoulement de la pompe Un peu d eau coulera peut tre pendant que l on coupera le tuyau Enlever toutes les bavures ou tous les copeaux laiss s par l outil de coupe NOTA Il ne sera peut tre pas n cessaire de couper les tuyaux galvanis s Si un raccord union se trouve proxim it de l emplacement o la pompe sera install e le d mon ter puis enlever en le d vissant le tuyau jusqu au del de l emplacement o la pompe
61. ut no water is delivered Improper priming Clogged water filter Note Unplug pump then open faucets and see if water is flowing through system Discharge valve closed Pipe size too small Impeller is plugged Pipes are frozen Re prime according to instructions Stop pump shut off water and change filter cartridge Filter should be installed on discharge side of pump Open valve Re pipe using pipe of the same size as suction and discharge ports on pump Clean impeller Thaw pipes Pump does not deliver water to full capacity Corroded pipes Piping is too small in size Pump not being supplied with enough water Low voltage Replace with plastic or new steel pipe Re pipe using pipe the same size as suction and discharge ports on pump Enlarge inlet pipe check well pump system Make sure outlet is at 115 Volts For parts or assistance call Simer Customer Service at 1 800 468 7867 1 800 546 7867 Repair Parts 4220 0702 Ace In The Hole Series Model 3075SS Key Part No 307588 No Description Used 1 2 HP 1 Pump Body Kit includes Bolts 1 FPP1801 2 Internal Parts Kit 1 FPP1870 3 Capacitor 1 171P5750 4 Wiring Box Cover Gasket Kit 1 FPP1802 5 Fan Guard 1 72151090 6 Shaft Seal and O Ring Kit 1 FPP1850 For parts or assistance call Simer Customer Service at 800 468 7867 1 800 546 7867 For parts or assistance call
Download Pdf Manuals
Related Search
Related Contents
LAP100 Netbook With Integrated 3G Module User Manual v1.0 Baumatic BO600SS Récepteur Terrestre Numérique SRT 5200/SRT 5202/SRT5205 Automatic Assurance/Quality Control Documentation Series USER MANUAL - Pool Technologie N Series Stepper Motor Driver 2M880N User Manual Videoregistratori digitali serie 40H+ Manuale Utente Hyundai H-CDM8064 User's Manual Laser Tool - DMC Equipamentos Lenovo ThinkCentre M90 Copyright © All rights reserved.