Home
Sanyo VCC-6594P User's Manual
Contents
1. gt gt gt gt lt 4 ees Video signal connections 12 V DC connection S a oie Push to insert the cable Connections to the camera Y C OUT connector 3 The POWER indicator A will light Adjust the picture on the i R monitor using the Brightness and Contrast controls The peripheral devices VCR monitor lens etc and cables are sold separately CAUTION e Please use a monitor with a Y C or S VIDEO input terminal or a 1 Using a coaxial cable twin type 75 ohms connect the Y C time lapse VCR with a S VIDEO input terminal OUT connector from the camera to the S VIDEO input terminal on the monitor or time lapse VCR e Use a Mini DIN round type 4 pin plug to connect to the Y C connector 2 Use a commercially available 12 V DC adaptor Never use a coaxial cable longer that 10 metres to connect the Connect an DC 12 V power source to the 12 V DC input terminal camera to the S VIDEO input terminal on the back of the camera 2A When using this unit the supplied clamping core A or B must be installed on the power cord and BNC cable in order to prevent electromagnetic interference to the other devices connected 10 English CONNECTIONS IF gt gt gt gt gt Basic connection for monitoring or recording The peripheral devices VCR monitor lens etc AC adaptor Video signal connections B gt gt VIDEO IN 55 gt VIDEO OUT and cables ar
2. A than required set switch 5 to the down NOR position 5 14 English SETTINGS E Backlight compensation setting This camera has two different backlight compensation functions Normally backlight compensation switch 6 MULT and 7 CENT Lt lt are set to the down OFF position Change the backlight compensation switch settings 6 7 depending on the conditions e MULT mode Use this position when applying backlight compensation to the whole of the screen e CENT mode Use this position when applying backlight compensation to only the central portion of the screen Note e H switches 6 and 7 are set to the up ON position at the same time the MULT setting will have priority e When MULT mode is set scenes with no backlighting may appear extremely dark and the object may appear over exposed If this happens set to CENT mode English 15 MULTI mode 64 sections CENT mode If using a VIDEO type auto iris lens e The ALC volume on the lens should be turned all the way to Av Average e H the backlight compensation function does not compensate properly for the conditions set using the LEVEL volume on the lens SETTINGS E White balance adjustment Normally the switch 8 WB is set to the down ATW auto white balance position and the white balance is adjusted automatically If a manual white balance adjustment is necessary follow the steps below Set the switch 8 WB to the up M manual
3. NOTE When using an auto iris lens the supplied clamping core B must be installed on the lens wire in order to prevent electromagnetic interference to the other devices connected English 7 MOUNTING THE LENS E Rewiring the lens cable in the lens iris plug 1 Prepare the lens cable Cut the cable at the plug then remove approx 8 mm of the cable sheath and strip about 2 mm from each wire 2 Install the lens iris plug Solder the cable to the pins following the correct pin layout refer to the table and illustrations then close the plug cover Pin layout DC type lenses VIDEO type lenses Brake coil 12 V DC 50 mA max Brake coil Not used Drive coil Video output 1 0 Vp p high impedance 1 2 3 4 E Flange back adjustment If the pick up surface is not correctly positioned with relation to the lens focal point the picture will be out of focus in particular when using auto iris power zoom lenses sold separately If that is the case adjust the flange back position as described below Drive coil Ground for video signal and DC power Using a screwdriver loosen the FLANGE BACK LOCK screw M2 Set the zoom lens to the maximum telephoto position set the focus using the focus ring on the lens Set the zoom lens to the maximum wide angle position set the focus using the FLANGE BACK ADJ screw Repeat steps 2 and 3 until the image stays in focus when changing from
4. position then adjust the colour e Turn RED VR302 to set the red ratio and or BLUE VR303 to set the blue ratio At OO VR302 VR303 Synchronization settings The default setting is internal synchronization INT You can change the power supply synchronization by moving switch 9 to the up LL position Refer to Line phase adjustment for details External sync adjustment VBS VCC 6592P only 1 Connect the VBS signal output for the other camera to the VBS IN connector at the rear of this camera 2 If the signals are not synchronized change the sub carrier SC P1 switches as follows Setting 9 pin OFF down Default Set to 90 counterclockwise OFF Set to 180 counterclockwise ON Set to 270 counterclockwise ON d e The sub carrier switches let you make broad adjustments to the sub carrier phase If finer adjustments are required contact the place of purchase e The type and length of the cable which is connected to the VBS connector may cause the horizontal synchronization being out of phase If this happens adjust VR304 H P horizontal sync 16 English SETTINGS E Lens iris adjustment If using a DC type auto iris lens you will need to set the LEVEL VR301 volume when shooting in the conditions described below VR301 L counterclockwise To decrease the contrast H clockwise To increase the contrast e H shooting simultaneously in a dark ro
5. Do not use the camera if smoke or a strange odour comes from the unit or if it seems not to function correctly Disconnect the power cord immediately and consult your dealer or a Sanyo Authorized Service Centre HB Do not open or modify Do not open the cabinet as it may be dangerous and cause damage to the unit For internal settings and repairs consult your dealer or a Sanyo Authorized Service Centre E Do not put objects inside the unit Make sure that no metal objects or flammable substance get inside the camera If used with a foreign object inside it could cause a fire short circuits or damages If water or a liquid gets inside the camera disconnect the power cord immediately and consult your dealer or a Sanyo Authorized Service Centre Be careful to protect the camera from rain sea water etc W Be careful when handling the unit To prevent damages do not drop the camera or subject it to strong shock or vibration W Install away from electric or magnetic fields If installed close to a TV radio transmitter magnet electric motor transformer audio speakers the magnetic field they generate will distort the image HB Protect from humidity and dust To prevent damages to the camera do not install it where there is greasy smoke or steam where the dampness may get too high or where there is a lot of dust E Protect from high temperatures Do not install close to stoves or other heat generating devices such
6. a telephoto shot to a wide angle shot When the setting is complete tighten the FLANGE BACK LOCK screw 8 English CONNECTIONS VCC 6592P only 4 1 I I I I REESEN Ps Video signal connections 12 V DC connection pp gt VIDEO IN 2 SS gt VIDEO OUT Push to insert the cable Basic connection for monitoring or recording 3 Insert the plug of this power cord into a wall outlet The POWER indicator A will light Adjust the picture on the The peripheral devices VCR monitor lens etc and cables are z monitor using the Brightness and Contrast controls etc sold separately 1 Make the video signal connection between the camera and W Coaxial cable type and maximum length the monitor or time lapse VCR e Cable type RG 59U 3C 2V 250 m maximum 2 Useacommercially available 12 V DC adaptor e Cable type RG 6U 5C 2V 500 m maximum Connect an DC 12 V power source to the 12 V DC input terminal e Cable type RG 11U 7C 2V 600 m maximum on the back of the camera CAUTION 2A When using this unit the supplied clamping core A or B must be e The RG 59U type cable should not be run through electrical installed on the power cord and BNC cable in order to prevent conduits or through the air electromagnetic interference to the other devices connected e Using CCTV Video grade coaxial cable English 9 CONNECTIONS VCC 6592P only
7. INSTRUCTION MANUAL BEDIENUNGSANLEITUNG MANUEL D INSTRUCTIONS ERW COLOUR CCD camera CCD Farbkamera Camera CCD COULEUR CCD About this manual e Before installing and using the camera please read this manual carefully Be sure to keep it handy for later reference e This manual gives basic connections and operating instructions for 2 PAL models VCC 6592P 6594P Uber diese Bedienungsanleitung e Lesen Sie bitte vor der Montage und dem Inbetriebnehmen der Kamera zuerst diese Bedienungsanleitung sorgfaltig durch und bewahren Sie sie zum spateren Nachschlagen auf e In dieser Anleitung finden Sie die Anschl sse und die Grundbedienung f r 2 PAL Modelle VCC 6592P und 6594P SANYO VCC 6592P VCC 6594P A propos de ce manuel e Avant d installer et d utiliser la cam ra veuillez lire ce manuel attentivement Gardez le a port e de main pour toute r f rence ult rieure e Ce manuel couvre les branchements et instructions pour l utilisation de base pour 2 mod les de format PAL VCC 6592P et 6594P KFARAH o CRRA EAM ZA TAN a EAR EA TB REET Dae a eee KU BECE2RNPALN EU VCC 6592P 6594P WAHRER Jr FUER VE DE SANYO Sanyo Electric Co Ltd 1AC6P1P2424 Printed in Japan L53H2 H4 XE 0901KPS DSP Depending on the conditions of use installation and environment please be sure to make the appropriate settings and adjustments If you need help with installation and or setting
8. as spotlights etc or where it could be subject to direct sunlight as that could cause deformation discoloration or other damages Be careful when installing close to the ceiling in a kitchen or boiler room as the temperature may raise to high levels Install where the temperature range will stay between 10 C and 50 C no condensation E Cleaning e Dirt can be removed from the cabinet by wiping it with a soft cloth To remove stains wipe with a soft cloth moistened with a soft detergent solution and wrung dry then wipe dry with dry soft cloth Do not use benzine thinner or other chemical product on the cabinet as that may cause deformation and paint peeling Before using a chemical cloth make sure to read all accompanying instructions Make sure that no plastic or rubber material comes in contact with the cabinet for a long period of time as that may cause damage or paint peeling HSITDNA 2 English PARTS NAMES VCC 6592P English 3 Video output connector VIDEO OUT BNC type Connect this connector to a device such as a VCR or monitor with a VIDEO IN connector Power input terminal e VCC 6592P 12 V DC input terminal 12 V DC GND e VCC 6594P 24 V AC input terminal AC 24 V AC 24 V GND Y C OUT connector 4 pin Separate Y luminance and C chroma signals are output from this terminal A better picture quality is obtained if the monitor or VCR is c
9. control setting HI NORM HI Aperture compensation setting SHRP NORM Backlight compensation setting BLC OFF MULT OFF Backlight compensation setting BLC OFF CENT OFF White balance switch MANU ATW and ATW colour R or B adjustment volume External sync setting SC PHASE1 0 External sync horizontal adjustment H adjustable ES EI GAIN APER Sch WB SC PHASE 1 HI SHRP MULT CENT MANU 180 90 a Auto iris lens setting A I LENS see page 6 DC D Lens iris level adjustment volume adjustable LSB NORM NORM OFF OFF ATW The sticker on the inside of cover 12 English SETTINGS VCC 6594P only The illustration shows the factory default settings for the switches in the camera setup section The camera settings are described on the assumption that a DC type auto iris lens is being used If you are using a VIDEO type auto iris lens be sure to read the Note which is given 2 OA VR301 oN ele Ess Che GAIN APER BLC WB 2 H SHRP MULT CENT MANU LL Con
10. e sold separately 1 Make the video signal connection between the camera and W Coaxial cable type and maximum length the monitor or time lapse VCR 2 Use a commercially available 24 V AC adaptor VCC 6594P only AC 24 V connection SCH Push to insert the cable SS 3 Insert the plug of this power cord into a wall outlet The POWER indicator A will light Adjust the picture on the monitor using the Brightness and Contrast controls etc e Cable type RG 59U 3C 2V 250 m maximum e Cable type RG 6U 5C 2V 500 m maximum Connect an AC 24 V power source to the AC 24 V input terminal e Cable type RG 11U 7C 2V 600 m maximum on the back of the camera CAUTION 2A When using this unit the supplied clamping core A must be e The RG 59U type cable should not be run through electrical installed on the power cord and BNC cable in order to prevent conduits or through the air electromagnetic interference to the other devices connected English 11 e Using CCTV Video grade coaxial cable SETTINGS VCC 6592P only The illustration shows the factory default settings for the switches in the camera setup section The camera settings are described on the assumption that a DC type auto iris lens is being used If you are using a VIDEO type auto iris lens be sure to read the Note which is given Control name Position High speed electronic shutter ES 1 50 sec Electronic iris El setting Auto gain
11. enon effect Use a manual or fixed iris lens and set the lens aperture to the shortest F stop Set the switch 1 3 to the up position The electronic iris is suitable for normal indoor use When the switch 1 3 is set to the up position do not use an auto iris lens If used under fluorescent light the image may flicker In such a case change to incandescent lighting or set the switch 1 3 to the down position and use an auto iris lens If conditions are outside the electronic iris operation range or more than the maximum illumination it will cause saturation of the CCD In that case use a manual iris lens Table A switch 1 3 1 50 Al 1 2 E Automatic Gain Control AGC setting The automatic gain control can be turned HI or NORM using the AGC switch 4 in the camera setup section HI Auto gain control fuction on 6 dB NORM Auto gain control normal gain lt 4 Note In the AGC switch position HI noise may be noticed in dark places of dimly lit objects In the AGC switch position NORM the noise will be reduced but the sensitivity will also be reduced to half in this case E Aperture The initial setting for switch 5 is up SHRP so that the contours of the object are emphasized However if the contours of the object are already emphasized more
12. m VCL CS2LY Ultra wide angle f 2 8 mm Greater telephoto angle f 16 mm W if using a VIDEO type auto iris lens e Set the ALC and LEVEL controls on the lens to adjust the iris Normally the ALC volume should be turned all the way to Av Average e Depending on the type of lens used the lens may not perform properly In such a case adjust the LEVEL volume on the lens casing to correct 6 English MOUNTING THE LENS Please use a DC type auto iris lens sold separately Check the lens mount Do not use a lens if the length L is more than 5 mm That may damage the camera and prevent proper installation C mount type lens 2 A w 1 Remove the lens mount cap from the camera Install the auto iris lens CS mount type lens Carefully align the lens mount with the camera opening then turn the lens slowly to install it C mount type lens To allow for flange back adjustment install the C mount adaptor option on the lens mount then carefully align the lens mount with the camera opening and turn the lens slowly to install it CS mount 3 Connect the lens plug to the lens iris output connector LENS on the side of the camera type lens When using lenses from other makers the plug shape may not correspond to the terminal on the camera In such a case remove the original plug and using a soldering iron connect the supplied lens iris plug according to the diagram Refer to page 8
13. n connector is used to send the DC control signal and power supply to an auto iris type lens Camera setup section under the cover These settings are for when using a 1 3 inch CS mount DC without EE internal amplifier type lens However if due to installation conditions or environment the settings may need to be modified for best results see SETTINGS To access the controls remove the cover fixing screw then remove the cover NOTE When using a 1 2 or 2 3 inch C mount VIDEO with EE internal amplifier auto iris type lens set the AL LENS switch to the VIDEO position English 5 CONCERNING AUTO IRIS LENSES VR301 DC VIDEO AL LENS EI DC type auto iris lens A lens without amplifier circuit that operates only on a DC power source In general this type of lens is referred to as DC type coil lens or DC type non amplifier lens Set the A I LENS switch to the DC position E VIDEO type auto iris lens A lens with amplifier circuit that operates on video signal and DC power source In general this type of lens is referred to as EE amplifier type lens ALC and LEVEL volume level controls are available on the lens for iris adjustments Set the A I LENS switch to the VIDEO position Hi Compatible auto iris lenses 1 3 inch Sanyo DC type lens VIDEO type lens VCL CS8LY Standard angle f 8 mm Standard angle f 9 mm VCL CS4LY Wide angle f A mm Telephoto angle f 12 m
14. om and through a bright window e If the subject background is extremely bright or dark e H the brightness of the picture on the monitor is not correct English 17 E Line phase adjustment VCC 6594P only When using a camera switcher to connect 2 cameras or more to one monitor there may be a vertical roll of the images when switched In such a case set as described below 1 2 Set the switch 9 SYNC to the up LL position Switch the display on the monitor from camera 1 to camera 2 Adjust the LINE PHASE volume on camera 2 until the vertical roll of the image stops If more than two cameras are used please repeat this procedure for all the cameras CAUTION If the vertical roll cannot be corrected by setting the LINE PHASE volume on camera 2 try setting the LINE PHASE volume on camera 1 If it still cannot be corrected please check that the polarity of the power cords of all connected devices is correct TROUBLESHOOTING Before taking the camera for repairs please check below to make sure that the camera is used correctly If it still does not perform correctly please consult your dealer or a Sanyo Authorized Service Centre EI No picture on the monitor screen e Is the power turned on to all connected devices Is the voltage correct e Are all the signal connecting cables correctly connected e Is the lighting sufficient e Has the lens cap been removed e Is the lens type DC or VIDEO correc
15. onnected to this connector Y signal ground C signal ground Y signal 1 0 Vp p 75 ohms unbalanced negative sync C signal 0 3 Vp p 75 ohms unbalanced Power indicator POWER Comes on when the power to the camera is on External sync composite video signal input connector VBS IN BNC type Connect to this connector the synchronizing signal output from a synchronizing signal device or the composite signal of a video distributor Line phase adjustment volume LINE PHASE VCC 6594P only When using two cameras or more the image on the monitor may roll vertically when switching sources This rolling can be minimized by turning this volume PARTS NAMES Lens mount cap The cap is installed to protect the lens mount section Remove the lens mount cap before installing a lens sold separately Flange back adjustment screw FLANGE BACK ADJ Flange back lock screw FLANGE BACK LOCK Camera installation bracket The bracket can be fixed at the top or bottom of the camera When fixing the bracket be sure to use the longer screws and install the shorter screws on the opposite side to seal the openings CAUTION When installing the camera support select a location that can support the total weight of the camera and accessories Shorter screws M3 x 4 Longer screws M3 x 6 Camera mounting screw hole 1 4 20 UNC 4 English PARTS NAMES Lens iris output connector LENS This 4 pi
16. s Environmental conditions 625 TV lines 25 frames sec Power supply Power consumption switchable VCC 6592P only Internal sync Line lock manually switchable VCC 6594P only 520 TV lines horizontally 400 TV lines vertically N Weight C Burst 0 3 Vp p 75 ohms VCC 6592P only More than 48 dB Approx 0 3 lux with a F 1 2 lens AGC HI Approx 0 6 lux with a F 1 2 lens AGC NORM Manual MULT CENT OFF switching Active when using an auto iris lens Al EI selectable by switches Electronic shutter 0 6 lux to 50 000 lux F 1 2 lens 7 speeds selectable by switches 1 50 1 120 1 500 1 1000 1 2000 1 4000 1 10000 sec 12 5 mm 0 5 mm ATW Manual switching CS mount HI NORM Temperature 0 C 50 C Humidity less than 90 no condensation 12 15 V DC VCC 6592P 24 V AC 50 Hz VCC 6594P VCC 6592P Approx 2 7 W with auto iris lens Approx 2 0 W without auto iris lens VCC 6594P Approx 2 8 W with auto iris lens Approx 2 1 W without auto iris lens Approx 310 g without lens SPECIFICATIONS HE Dimensions oe 1 4 20 UNC VCC 6592P VCC 6594P Features and specifications are subject to change without prior notice or obligations 20 English
17. s please consult your dealer CONTENTS PRECAUTIONS csssssssssssssssessssessseessseesssessssseessseessseesssseessseessaensans 2 ELO H CONCERNING AUTO IRIS LENSES MOUNTING THE LENS enneesssseessseennsssenunseonuneennsneunuszennunseunnnensnnneununnen CONNECTIONS ses 9 KU 12 TROUBLESHOOTING usneesssseonnssesnsseesunnsenusssenunsesnunsenunnsenunssununneunnn 18 SPECIFICATIONS ACCESSORIES Lens iris plug pn DC Clamping core A VCC 6594P oo ccccccccccccscsceeseteesteeteestsseeseees 2 pc VOC 6592P occ ccccccccessessessessessessessessesseseeesess 3 pc Clamping core B VCC 6594P nnnnnnnnnnnenn 1 pe VEG6592 Po n aaa E S Enni 2 pc English 1 FEATURES e Built in interline transfer method 1 3 CCD approx 470 000 picture elements e Equipped with a DSP Digital Signal Processor function e Horizontal resolution more than 520 TV lines e High sensitivity minimum required illumination is 0 3 lux F1 2 AGC HI position e Two types of backlight compensation functions multi spot photometry and center focus photometry e Low smear anti blooming low lag no burning and no geometric distortion using the CCD solid state image device e 100 solid state components giving excellent immunity to shock and vibration e Not subject to interference from magnetic or electrostatic fields e Power supply 24 V AC operation VCC 6594P 12 V DC operation VCC 6592P PRECAUTIONS EB In case of problem
18. tly selected Depending on the type of lens the A I LENS switch must be set accordingly e Is the iris control correctly set EB The picture is not clear e Is the monitor correctly adjusted e Is the flange back position correctly set e Is the lens focus correctly adjusted e Are the lens surfaces clean f there is dust or finger prints on the lens the image quality will deteriorate To clean the lens use a soft cloth or a commercially available lens cleaning set SERVICE This camera is a precision instruments and if treated with care will provide years of satisfactory performance However in the event of a problem the owner is advised not to attempt to make repairs or open the cabinet Servicing should always be referred to your dealer or Sanyo Authorized Service Centre 18 English SPECIFICATIONS E Camera Scanning system Interlace Image device Picture elements Effective picture elements Synchronizing system Resolution Video output level Y C signal outputs Video S N ratio Minimum required illumination incandescent lighting Backlight compensation Iris function Electronic iris range Electronic shutter Flange back White balance Lens mount AGC English 19 PAL standard PLL 2 1 interlace 1 3 inch solid state image device CCD 795 H x 596 V 752 H x 582 V Internal sync External sync automatic 1 0 Vp p 75 ohms composite Y Video 0 7 Vp p sync 0 3 Vp p 75 ohm
19. trol name Position High speed electronic shutter ES Electronic iris El setting 1 50 sec Auto gain control setting HI NORM HI Aperture compensation setting SHRP NORM Backlight compensation setting BLC MULT OFF Backlight compensation setting BLC CENT OFF White balance switch MANU ATW and colour R or B adjustment volume Syncronisation SYNC setting INT LL Auto iris lens setting A I LENS see page 6 DC LSB NORM NORM OFF OFF ATW The sticker on the inside of cover English 13 So 9 B 8 9 Lens iris level adjustment volume adjustable SETTINGS E Electronic shutter settings and electronic iris When all of these switches are down electronic shutter 1 50 sec or settings auto iris setting is enabled The electronic shutter can be set to one of 7 speeds as shown in Table A Furthermore when all switches are up electronic iris setting is enabled Notes on the electronic shutter Using the high speed electronic shutter indoors with low lighting will give darker pictures In such a case add some lights to make sure the lighting is sufficient If the lighting is very bright pay attention to the light angle in order to avoid or minimize the smear phenom
Download Pdf Manuals