1. HRUCCEDCON 6 Be RS232 Gei 06 o 3 PL ma LI EG SAVE SEE IS RRS sl Is eg el DI ls p L Sy a 13 O Q L Q 210 Jla e Sr Q Ks RS9006PNG O l Figure 2 3 Rear Panel Mounting RuggedCom RuggedSwitch 12 RS900GP Installation Guide Rev 100 2 Installation 2 2 3 RS900GP Side Panel Mount Option The side panel mounting brackets fit flush with the side of the RS900GP ee Gil RS232 So OI D 8 Y J KE ea
2. IS RSSOOGPNC 8 11 Figure 2 4 Side Panel Mounting 1 21 1 50 1 63 202000 222000 7 46 7 71 RuggedCom RuggedSwitch TM 13 RS900GP Installation Guide Rev 100 2 Installation 2 3 DC Power Supply Wiring and Grounding a 9 8 00 GID He fe V TETSU ONdOLOGSE Q Q 1 LS DC Input A DC Input B Surge Ground Surge Ground DC Input A DC Input B
3. EE GER Power LED RS232 be RS232 Serial bo OY Ports 9 10 Configurable 00 o A Alarm LED 1000 Base LX Gigabit Ethernet PU x shown Dz Fail Safe Relay amp SAVE SI J O dy Power Supply A L Alen Ground Ports 1 8 Ju 8 L Gelz 10 100 Base Tx ls S L EI Le Power Supply B Ju 4 Ground Pot BS RSS00GPNC Figure 1 1 RS900GP Front Panel Power LED JD Green steady Power is on Alarm LED A Red steady Alarm condition exists BB Ethernet Port 1 8 Link LED i 1 Green steady Network link ID d Ethernet Port 1 8 Link LED Green blinking Network activity OI L L Ethernet Port 1 8 PoE LED d 1 Orange steady PoE is enabled and powered on H NIPA Ethernet Port 1 8 PoE LED EF PS Orange blinking PoE is enabled and powered off Ethernet Port 1 8 PoE LED i 1 Off PoE is disabled Table 1 1 Front Panel LED Definitions RuggedCom RuggedSwitch TM RS900GP Installation Guide Rev 100 2 Installation 2 Installation 2 1 DIN Rail Mounting An optional DIN rail mounting bracket is available for the RS900GP
4. 2 E D i 7 0 REF yr Ir le LESE E y 1 I enpARFS BADARE RSSOOGPNC FRONT FE LU 134 S JI PITYTIVNINVL TOP j 6 8 REF j 6 1 REF j U 3 e e e Q 3 e e e SIDE Figure 3 1 RS900GP Physical Dimensions Dimensions 6 95 x 3 63 x 6 08 inches 17 653 x 9 22 x 14 4432 cm Length x Width x Depth Weight To be determined Ingress Protection IP40 1mm objects Enclosure Cast Aluminum Table 3 8 Physical Specifications RuggedCom RuggedS
5. o Gil Rs232 Gei ro PU SO Si 54V 552 SI 7 S 6 5 gc Sy al 8 10 2 o E PoE Y RSS00GPNC I 3 37 Figure 2 1 DIN Rail Mounting 22200 22200 RuggedCom RuggedSwitch TM 10 RS900GP Installation Guide Rev 100 2 Installation 2 2 Panel Mounting Options The RS900GP can be equipped with front rear or side panel mount brackets 2 2 1 RS900GP Front Panel Mount Option The front panel mounting brackets fit flush
6. RuggedSwitch TM RS900GP Hardware Installation Guide Revision 100 November 10 2011 www RuggedCom com RuggedSwitch RS900GP RuggedSwitch RS900GP Hardware Installation Guide Copyright 2011 RuggedCom Inc All Rights Reserved Dissemination or reproduction of this document or evaluation and communication of its contents is not authorized except where expressly permitted Violations are liable for damages All rights are reserved particularly for the purposes of patent application or trademark registration This document contains proprietary information which is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of RuggedCom Inc Disclaimer Of Liability We have checked the contents of this manual against the hardware and software described However deviations from the description cannot be completely ruled out RuggedCom shall not be liable for any errors or omissions contained herein or for consequential damages in connection with the furnishing performance or use of this material The information given in this document is reviewed regularly and any necessary corrections will be included in subsequent editions We appreciate any suggested improvements We reserve the right to make technical improvements without notice Registered Trademarks ROX RuggedBackbone RuggedRated and
7. of different transceiver choices for Gigabit fiber optic communications The following table details fiber optic specifications based on the order code transceiver selected at time of ordering 50u 125 2LC10 SM LC 1310 9u 125 9 5 3 22 3 10 2LC25 SM LC 1310 9u 125 5 0 22 3 25 2SC10 SM SC 1310 9u 125 10 3 22 3 10 2SC25 SM SC 1310 9u 125 7 3 24 3 25 SFP MM LC 850 50u 125 8 5 4 22 3 0 5 SFP SM LC 1310 9u 125 9 3 24 0 10 SFP SM LC 1310 9u 125 7 3 26 3 25 SFP SM LC 1550 9 125 5 0 26 0 50 SFP SM LC 1550 94 125 0 5 26 0 80 SFP Ge 1310 94 125 9 3 22 3 10 ert Se SS 1490 94 125 9 3 22 3 10 All cabling is duplex type unless otherwise specified ai optical power numbers are listed as dBm averages Maximum segment length is greatly dependent on factors such as fiber quality and number of patches and splices Please consult RuggedCom sales associates when determining maximum segment distances d These transceivers utilize a distributed feedback DFB type laser and are rated for 20 C to 85 C operation only Table 3 7 Fiber Optic Port Specifications RuggedCom RuggedSwitch 19 RS900GP Installation Guide Rev 100 3 Specifications 3 6 Physical Dimensions UGCEDCOM i DUSTRIAL STRENGTH NETWOI m ES RS232 EI 2 H
8. precautions that shall be taken and access is through the use of a tool or lock and key or other means of security and is controlled by the authority responsible for the location Caution Hot Surfaces When in operation regions of the unit surface may be hot Caution Lithium Battery This product contains a Lithium battery that is not replaceable by the operator or by service personnel RuggedCom RuggedSwitch 6 RS900GP Installation Guide Rev 100 1 Product Overview 1 Product Overview The RuggedSwitch RS900GP is an industrially hardened fully managed Ethernet switch providing dual fiber optical Gigabit Ethernet ports and eight Fast Ethernet copper ports each capable of supplying high power 802 3at compliant power over Ethernet Designed to operate reliably in harsh industrial environments the RS900GP provides a high level of immunity to electromagnetic interference and heavy electrical surges typical of environments found in electric utility substations factory floors or in curb side traffic control cabinets An operating temperature range of 40 C to 85 C coupled with hazardous location certification a powder coated aluminum enclosure and optional conformal coating allows the RS900GP to be placed in almost any location The embedded Rugged Operating System ROSTM provides advanced networking features such as Enhanced Rapid Spanning Tree eRSTP Port Rate Limiting and a full array of intelligent function
9. with the front of the RS900GP 2 00 H 1 50 _ I I YU I E N D SE L 304 CQ 09 o A 3 f I ma Br H AV S Sn 28 S 8 IL 7 S Q 6 5 e Sy al 3 Q Ol Q Bee 210 Jla A el IS RS900GPNC 0 z r Figure 2 2 Front Panel Mounting RuggedCom RuggedSwitch 11 RS900GP Installation Guide Rev 100 2 Installation 2 2 2 RS900GP Rear Panel Mount Option The rear panel mounting brackets fit flush with the rear of the RS900GP 2 00 1 50
10. 2 IEC 60255 21 2 Shock 30g 11 ms Class 2 Table 3 11 IEC Environmental Type Tests RS900GP Installation Guide Rev 100 RuggedCom RuggedSwitch 22 3 Specifications 3 8 Agency Approvals Ce CSA CSA C22 2 No 60950 UL 60950 Approved GE EN 60950 EN 61000 6 2 DEELEN FCC FCC Part 15 Class A Approved CISPR EN55022 Class A Approved FDA CDRH 21 CFR Chapter 1 Subchapter J Approved IEC EN EN60825 1 1994 A11 1996 A2 2001 Approved Hazardous Locations CSA Class 1 Division 2 Groups A B C amp D Approved T6 rating at 40 C T4A rating at 85 C With the use of shielded Ethernet cables Table 3 12 Agency Approvals RuggedCom RuggedSwitch 23 RS900GP Installation Guide Rev 100 Appendix A Warranty Appendix A Warranty RuggedCom warrants this product for a period of five 5 years from the date of purchase This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void For warranty details visit www RuggedCom com or contact your customer service representative Should this product require service contact the factory at RuggedCom Inc 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Phone 1 905 856 5288 Fax 1 905 856 1995 RuggedCom RuggedSwitch 24 RS900GP Installation Guide Rev 100
11. Figure 2 5 DC Power Supply Wiring and Grounding The RS900GP low voltage DC power supply features reverse polarity protection and dual independent inputs This feature allows the connection of two DC sources with the same nominal voltage to provide redundant power supply inputs The DC source must be connected to the DC inputs according to the polarity markings on the unit Equipment must be installed according to the applicable country wiring codes Surge Ground should be connected to Chassis Ground via a braided cable or other appropriate ground wire Chassis Ground must be connected to the protective earth All line to ground transient energy is shunted to the Surge Ground terminal In cases where users require the DC inputs to be isolated from ground remove the ground braid between Surge and Chassis Ground Note that all line to ground transient protection circuitry will be disabled JOALIALIALLAS MAMA Figure 2 6 RS900GP Chassis Ground Connection g RuggedCom RuggedSwitch 14 RS900GP Installation Guide Rev 100 2 Installation 2 4 Failsafe Output Wiring and Specifications The Failsafe output relay is provided to signal critical error conditions that may occur on the RS900GP The contacts are energized upon power up of the unit and remain energized un
12. Ports Signal Description The RS900GP has several 10 100BaseTX ports that allow connection to standard CAT 5 UTP cable with RJ45 male connectors The RJ45 receptacles are directly connected to the chassis ground on the unit and can accept shielded CAT 5 cables If shielded cables are used care must be taken to ensure the shielded cables do not form a ground loop via the shield wire and the RJ45 receptacles at either end Pin 8 Pin 1 Figure 2 9 RJ45 Port Connector 1 RX A 2 RX A 3 TX B 4 NC C 5 NC C 6 TX B 7 NC D 8 NC D Table 2 2 RJ45 Ethernet Pin Assignment RuggedCom does not recommend the use of CAT 5 cabling of any length for critical real time substation automation applications However transient suppression circuitry is present on all copper ports to protect against damage from electrical transients and to ensure IEC 61850 3 and IEEE 1613 Class 1 conformance This means that during the transient event communications errors or interruptions may occur but recovery is automatic RuggedCom also does not recommended to use these ports to interface to field devices across distances which could produce high levels of ground potential rise i e greater than 2500V during line to ground fault conditions RuggedCom RuggedSwitch 16 RS900GP Installation Guide Rev 100 3 Specifications 3 Specifications 3 1 Operating Environment Ambient Tempe
13. ality for high network availability and manageability Ethernet Ports e Up to 2 Fiber Optic Gigabit Ethernet Ports 100 1000BaseX e 8 Fast Ethernet Ports 10 100BaseTX all external 802 3af 802 3at compliant PoE e Up to 2 10 100 1000 BaseTX copper ports e Full compliance with IEEE 802 3 802 3u and 802 3z e Non blocking store and forward switching e Full duplex operation and flow control IEEE 802 3x Industry standard fiber optical connectors LC SC SFP e Bi Directional simplex fiber support Long haul optics allow Gigabit distances up to 70km Power Over Ethernet PoE e 8 10 100 BaseTx 802 3af 802 3at compliant ports Data and power over a single Ethernet cable e Auto sensing ports that provide power only to PoE end devices RuggedRated for Reliability in Harsh Environments e Meets IEEE 1613 electric utility substations e Exceeds IEC 61850 3 electric utility substations e Exceeds IEEE 61800 3 variable speed drive systems e Exceeds IEC 61000 6 2 generic industrial environment e Exceeds NEMA TS 2 traffic control equipment e Hazardous Location Certification Class 1 Division 2 e 40 to 85 C operating temperature no fans e Conformal coated circuit boards optional e Rugged powder coated aluminum enclosure RuggedCom RuggedSwitch 7 RS900GP Installation Guide Rev 100 1 Product Overview Power Supply 2 redundant 54VDC inputs 51 57VDC e Supports 8 30W PoE powered devices minim
14. e of Contents FCC Statement And Cautions sara 6 1 Ge e de 7 1 1 RS900GP Front E 9 e ERE EET EE 10 21 DIN RA Migrene 10 2 2 Panel Mounting Options v uesnnanemensmsdmtnnn items home tinde nltndte 11 2 2 1 RS900GP Front Panel Mount Option rrrrnnrrnnrrnnnorvrrrnnnrenrrnnnnnnnvrnnnnrnnrnnerernr 11 2 2 2 RS900GP Rear Panel Mount Option uvenner 12 2 2 3 RS900GP Side Panel Mount CIE 222538 masi 13 2 3 DC Power Supply Wiring and Grounding rerennvvnnnnnnnvvnnnnnnrrnnnnnnrrrrnnnennrrnnnennnnnnereenn 14 2 4 Failsafe Output Wiring and Specifications rrrrnnrrrnnnnnnnvnnnnnnnrnnnnorrrrrnnnrnnrrnnennnnnnne 15 25 R9232 Port Wing sienien ent E a ERE EE N 15 2 6 RJ45 Ports Signal Description E 16 Klee de ne ee ee 17 3 1 Operating Environment E 17 3 2 Power Supply Ee EE 17 22 IN RR EN EE NR RE NE 17 KN 17 EE NN 17 3 3 Failsafe Relay Specifications E 17 3 4 Twisted Pair Data Port Specifications 1 28 titine nite 18 3 5 Fiber Optic EE 19 3 6 Physical Dimensions een es eee 20 3 7 Type Test Seele ss samedis 21 3 7 1 IEC 61850 3 Type T l Heen 21 3 7 2 IEEE 1613 WK 22 3 7 3 IEC Environmental Type Tests AAR 22 29 Agency ADDrOVAIS secnnade naaie EAE N nase 23 Ae Waray eren 24 RuggedCom RuggedSwitch 3 RS900GP Installation Guide Rev 100 RuggedSwitch RS900GP List of Figures 1 1 RS900GP Fr nt FAN as 9 2 1 DIN Rail Mounting Sa EE 10 2 2 Front Panel Mounting EE 11 2 3 Rear Pan
15. eRSTP are trademarks of RuggedCom Inc ROS RuggedRouter and RuggedSwitch are registered trademarks of RuggedCom Inc Other designations in this manual might be trademarks whose use by third parties for their own purposes would infringe the rights of the owner Linux is the registered trademark of Linus Torvalds in the U S and other countries The registered trademark Linux is used pursuant to a sublicense from LMI the exclusive licensee of Linus Torvalds owner of the mark on a world wide basis Warranty Five 5 years from date of purchase return to factory For warranty details visit www RuggedCom com or contact your customer service representative Contacting RuggedCom Corporate Headquarters RuggedCom Inc 300 Applewood Crescent Concord Ontario Canada L4K 5C7 Tel 1 905 856 5288 Fax 1 905 856 1995 Toll free 1 888 264 0006 US Headquarters RuggedCom 1930 Harrison Street Suite 209 Hollywood Florida USA 33020 Tel 1 954 922 7938 ext 103 Fax 1 954 922 7984 Toll free 1 888 264 0006 Europe Headquarters RuggedCom Unit 41 Aztec Centre Aztec West Almondsbury Bristol United Kingdom BS32 4TD Tel 44 1454 203 404 Fax 44 1454 203 403 Email RuggedSales RuggedCom com Technical Support Toll Free North America 1 866 922 7975 International 1 905 856 5288 Email Support RuggedCom com Web www RuggedCom com RuggedSwitch RS900GP Tabl
16. el Mouning EE 12 2 4 Side Panel NTT 13 2 5 DC Power Supply Wiring and Grounding ss 14 2 6 RS900GP Chassis Ground Connection ss 14 2 7 Faillsat Output E 15 2 8 RS232 Female Connector EE 15 2 9 RJ45 POM BIEN Lan eege 16 3 1 RS900GP Physical Dimensions ii 20 RuggedCom RuggedSwitch 4 RS900GP Installation Guide Rev 100 RuggedSwitch RS900GP List of Tables 1 1 Front Panel LED Definitions er 9 2 1 RS232 Female DCE Pinout EE 15 2 2 RJ45 Ethernet Pin Assignment uk 16 Sule Operating len E E 17 3 2 RS900GP eeler E 17 3 3 IEEE802 3AF Power Supply Ratings lt mem nnmeeinvnieinninenneiemev unne 17 3 4 IEEE802 3AT Power Supply Ratings ss 17 3 5 Failsafe Relay Specifications ususeesatnemnisssdnmemeddme venn nettes ete tint 17 3 6 Twisted Pair Data Port Specifications eege ege ties ie hese aaa ice 18 3 7 Fiber Optic Port Specifications Gunnes nan mines 19 3 8 Physical Specifications EE 20 3 9 RS900GP IEC 61850 3 Type Tests sonneries 21 3 10 RS900GP IEEE 1613 Type Te 22 3 11 IEC Environmental Type Test ns attir e tetteiventiadianttimelans 22 Fo my Ee Ee TE 23 RuggedCom RuggedSwitch 5 RS900GP Installation Guide Rev 100 FCC Statement And Cautions FCC Statement And Cautions Federal Communications Commission Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Pa
17. ower ports 5kV N A Table 3 9 RS900GP IEC 61850 3 Type Tests RuggedCom RuggedSwitch 21 RS900GP Installation Guide Rev 100 3 Specifications 3 7 2 IEEE 1613 Type Tests IEEE Test IEEE 1613 Clause Description Test Levels Enclosure Contact SKV C37 90 3 9 ESD Enclosure Air 12kV C37 90 2 8 Radiated RFI Enclosure ports 35 V m Signal ports ey 2 5kHz C37 90 1 7 Fast Transient D C Power ports RSC Earth ground ports 2kV 2 2kV Signal ports ee oe mode 1MHz C37 90 1 7 Oscillatory 2 2KkV common amp D C Power ports differential mode 1MHz 5 kV Failsafe Signal ports C37 90 6 H V Impulse Relay D C Power ports 5 kV 2kV Signal ports AC Failsafe C37 90 6 Dielectric Strength Relay D C Power ports 1 2kV DC Table 3 10 RS900GP IEEE 1613 Type Tests D If the unit contains copper ports the IEEE 1613 conformance is Class 1 During disturbance errors may occur but recovery is automatic e If the unit contains all fiber ports the IEEE 1613 conformance is Class 2 During disturbance no errors will occur 3 7 3 IEC Environmental Type Tests Test Ad 40 C 16 Hours N A IEC 60068 2 1 Cold Temperature IEC 60068 2 2 Dry Heat Test Bd 85 C 16 Hours N A SH Humidity Damp 95 non condensing IEC 60068 2 30 Heat Cyclic Test Db 55 C 6 cycles N A IEC 60255 21 1 Vibration 2g 10 150 Hz Class
18. rature as measured Ambient Operating Temperature 40 to 85 C from a 30cm radius surrounding the center of the RS900GP enclosure Ambient Relative Humidity 5 to 95 Non condensing Ambient Storage Temperature 40 to 85 C Operating Altitude 0 to 15240m 0 to 50000 ft Over temperature range of 40 to 85 C Table 3 1 Operating Environment 3 2 Power Supply Specifications 3 2 1 General 54 VDC 45 VDC 57 VDC 6 3A T 1 5 kV DC 15W 273W a T denotes time delay fuse Table 3 2 RS900GP Power Supply Specifications 3 2 2 IEEE802 3AF 45 57 VDC 3 5 A MAX 44 57 VDC 15 W PORT MAX Table 3 3 IEEE802 3AF Power Supply Ratings 3 2 3 IEEE802 3AT 51 57 VDC 6 A MAX 50 57 VDC 30 W PORT MAX Table 3 4 IEEE802 3AT Power Supply Ratings 3 3 Failsafe Relay Specifications Max Switching Voltage 30VAC 80VDC 0 3A 30VAC 1A 30VDC 0 3A 80VDC Rated Switching Current Table 3 5 Failsafe Relay Specifications O e Resistive Load e For Class 2 circuits only RuggedCom RuggedSwitch 17 RS900GP Installation Guide Rev 100 3 Specifications 3 4 Twisted Pair Data Port Specifications 10 100 Mbps Cat 5 UTP or STP 100m RJ45 Table 3 6 Twisted Pair Data Port Specifications RuggedCom RuggedSwitch 18 RS900GP Installation Guide Rev 100 3 Specifications 3 5 Fiber Optic Port Specifications For maximum flexibility RuggedCom Inc offers a number
19. rt 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Caution LASER This product contains a laser system and is classified as a CLASS 1 LASER PRODUCT Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Caution Service This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void Changes or modifications not expressly approved by RuggedCom Inc could invalidate specifications test results and agency approvals and void the user s authority to operate the equipment Should this device require service refer to Appendix A Warranty in this guide Caution Physical Access This product should be installed in a restricted access location where access can only be gained by service personnel or users who have been instructed about the reasons for the restrictions applied to the location and about any
20. til an alarm condition or power loss occurs N A amp r r ETETETE eilelzelle DE m 8 S 1 1 i f Lt r7 2 CD Ei a I HH gull 3 b g vis Q D l 9 g ceHHHHRS BARA 2 N Normally Closed Normally Open Common Figure 2 7 Failsafe Output Relay 2 5 RS232 Port Wiring The RS232 port is used for configuring the unit A straight through serial cable with a DB 9 connector is required There is no need to crossover the Transmit and Receive signals from the PC side since this has been done internally as shown in the figure below 66660 Seog Figure 2 8 RS232 Female Connector No Connection Transmit Data Receive Data No Connection Ground No Connection No Connection III A j N No Connection o No Connection Table 2 1 RS232 Female DCE Pinout O This port is not intended to be a permanent connection and the cable shall be less than 2m 6 5 ft in length RuggedCom RuggedSwitch 15 RS900GP Installation Guide Rev 100 2 Installation 2 6 RJ45
21. um 260W total output e Supports power supply sharing Reverse polarity protection e CSA UL 60950 safety approved to 85 C Simple Plug and Play Operation e Plug and play operation 802 3af 802 3at Automatic learning of up to 8192 MAC addresses e Auto negotiation on all 10 100BaseTX ports e Auto MDI MDIX crossover on all 10 100BaseTX ports e LED indicators for Link Activity and Power ROS Advanced Network Management e Enhanced Rapid Spanning Tree eRSTPTM e Quality of Service 802 1p for real time traffic e Port rate limiting 128kbps to 8Mbps e VLAN 802 1q with double tagging e IGMP Snooping for multicast filtering e Port configuration status statistics mirroring security Loss of link management on fiber ports e Web based Telnet CLI management interfaces e SNMP v2 and RMON Rich set of diagnostics with logging and alarms RuggedCom RuggedSwitch 8 RS900GP Installation Guide Rev 100 1 Product Overview 1 1 RS900GP Front Panel Chassis Ground Connection on top of heatsink fin
22. witch 20 RS900GP Installation Guide Rev 100 3 Specifications 3 7 Type Test Specifications 3 7 1 IEC 61850 3 Type Tests 4 Enclosure Contact 8kV IEC 61000 4 2 ESD Enclosure Air 15kV IEC 61000 4 3 Radiated RFI Enclosure ports 20 V m D Signal ports 2KV 2 5kHz D IEC 61000 4 4 Burst Fast Transient D C Power ports 2kV Earth ground ports 2kV Signal pore 2kV line to earth 4 eege 5 SES 1 5KV line to line 4 urge S ES Bar bert 1 5kV line to earth 3 bes P 1kV line to line Signal ports 10V IEC 61000 4 6 Induced Conducted RFI D C Power ports 10V Earth ground ports 10V ee 40 A m continuous IEC 61000 4 8 Magnetic Field Enclosure ports 1000 A m for 1s N A 30 for 0 15 60 for IEC 61000 4 29 Voltage Dips amp Interrupts D C Power ports 0 18 100 for 0 055 N A Signalioors 2 5kV common 1kV 3 SS differential mode 1MHz IEC 61000 4 12 Damped Oscillatory DC Pawar borts 2 5kV common 1kV 3 da P differential mode 1MHz Signal ports 30V Continuous 300V for 1s IEC 61000 4 16 Mains Frequency Voltage D C Power ports 30V Continuous 300V for 1s IEC 61000 4 17 Ripple on D C Power Supply D C Power ports 10 1 5kV AC Fail Signal ports N A IEC 60255 5 Dielectric Strength ok Safe Relay output D C Power ports 1 5kV DC N A EE TE l Signal ports 5kV Fail Safe Relay output N A V Impulse D C P