Robertshaw RS4220C User's Manual

image

Contents

1. U Lo E FL Timer to remind the home owner to maintain the filter Default setting is off The timer runs when the system is on and can be set at n OFF or y ON When set to y the filter reminder FL will appear after 1000 hours of system operation Press the and W buttons to restart the filter timer FL n CY Cycle Timer allows a compressor to rest between cycles Can be set from 0 to 5 minutes in 1 min increments CS WARNING A wrong short cycle setting can damage your equipment This should only be changed by a trained HVAC professional CL Calibration offset Changes the displayed temperature from the actual temperature by 3 to 3 degrees in one degree increments Increasing the offset by 2 will cause the thermostat to display a temperature that is 2 degrees higher than the actual room rs LL Creating a Password Protect the Settings The buttons on the front of the thermostat can be locked with a password To create a password 1 Press the and buttons at the same time and hold them in for 5 seconds You will be asked for a 2 digit password 2 The digits are set using the amp and W buttons to progress through 00 to 99 Press the GX to move to the next digit Press 8 to move back 3 The password is saved after 5 seconds All of the front buttons are now locked out until the password is entered Pressing any button will cause amp to flas
2. Changez imm diatement les piles Changez les piles si vous laissez le thermostat sans surveillance pendant plus de 30 jours Description g n rale L affichage du thermostat indiquera l information qui est utilis e lors du fonctionnement ou de la programmation Cette illustration indique toutes les possibilit s d affichage avec une explication a 4 68 no o SETAT CIC ee 85 Le 5 Ao Fa A Va a Fl 6 Utilis avec une valeur de r glage Utilis pour la valeur de r glage actuelle et certaines donn es de configuration Mode et tat du CVC Les ic nes clignotent pendant l activit A indique Auto 2 indique le second tage de fonctionnement E indique le mode d urgence Indique l activation du syst me de s curit Indicateur de d charge de la pile Utilis pour la temp rature ambiante et la date de configuration par ex diff rentiel du premier tage d quipement F ou C etc 7 Indicateur de ventilation tourne quand le ventilateur est actif 8 La s lection du mode ventilateur se fait en appuyant sur la touche du VENTILATEUR 3 o N ous R glages programmables par l utilisateur valeurs par d faut Pendant tous les changements de programmation l affichage retourne l affichage du fonctionnement si vous n appuyez sur aucune touche dans les 10 secondes La temp rature est en Fahrenheit La lumi re de nuit est allu
3. 2 tage AUTO d quipement fonctionne l affichage indiquera le 6 Yam num ro 2 c t des symboles de chauffage et de climatisation Un diff rentiel programmable de la temp rature la valeur par d faut est de 2 F ou de 1 C et un d lai de temporisation la valeur par d faut est de 20 minutes contr le le cycle du 2 tage Le 2 tage d quipement s allume quand e _ La temp rature de la pi ce s carte de la valeur de r glage par la somme des valeurs de r glage des diff rentiels du ler et 2 tages d quipement e Le premier tage a fonctionn pendant tout le d lai de temporisation mais le chauffage ou la climatisation n a pas atteint le niveau requis Syst mes trois tages de fonctionnement Un 3 me tage d quipement est un troisi me o SET AT syst me ou un syst me suppl mentaire qui ey fournira du chauffage suppl mentaire dans les C H H AUTO Ea applications avec thermopompes 36 Com Quand un 3 tage d quipement fonctionne l affichage indiquera le num ro 2 et un E c t du symbole de chauffage Une temporisation la valeur par d faut du d lai est de 20 minutes contr le le cycle du 3 tage Cette temporisation commence quand le second tage de l quipement se met en route Affichage r tro clair Ce thermostat est muni d un r tro clairage pour une lecture facile de l affichage Appuyez sur Q pour activer le r
4. de droits suppl mentaires pouvant varier d un tat ou d une province l autre Pour les renvois sous garantie exp diez le thermostat en port pay a Invensys Controls Warranty Claims Department 515 S Promenade Corona CA 91719 Au Canada Invensys Controls 3505 Laird Road Unit 14 Mississauga Ontario L5L 5Y7 Canada Attn Warranty Department Service des garanties Invensys Controls 515 South Promenade Avenue Corona CA 92879 1736 tats Unis d Am rique www invensyscontrols com 2008 Invensys Controls 2 08 352 00058 001 Rev B
5. me se met en route trop souvent Le ventilateur du syst me ne fonctionne pas correctement Le thermostat n indique pas la temp rature ambiante correcte L cran affiche HI ou LO mais la temp rature ambiante est normale V rifiez le c blage Voir la section sur le sch ma de c blage Augmentez le diff rentiel de la temp rature Voir la section pour changer les valeurs chelle horloge diff rentiel heures du filtre cycle court ou talonnage R glez le commutateur du ventilateur sur l option gaz ou lectricit de mani re correspondre au syst me Voir la section sur l emplacement des interrupteurs V rifiez la s lection F C Fahrenheit Celsius Voir la section sur l chelle ou l talonnage Appelez un technicien qualifi pour le d pannage ou le remplacement Si vos probl mes de thermostat ne peuvent pas tre r solus contactez www invensyscontrols com ou Assistance technique 800 445 8299 Garantie limit e de cinq ans Invensys Controls garantit l entrepreneur installateur d origine ou au consommateur utilisateur d origine que chaque nouveau thermostat Robertshaw est d pourvu de tout d faut de mat riau et de main d oeuvre dans des conditions normales d utilisation et d entretien pendant une p riode de cing 5 ans compter de la date d achat Cette garantie et notre responsabilit ne s appliquent pas aux piles ou aux marchandises qui sont endommag es l
6. temp rature programm e le syst me s allume Si le syst me s allume trop souvent augmentez le r glage de cette valeur diff rentielle Notez qu un plus grand diff rentiel permettra davantage de changements de temp rature ambiante avant la mise en route du syst me TRE J d2 diff rentiel de deuxi me niveau d quipement fonctionne avec le premier tage de l quipement pour contr ler un deuxi me syst me de chauffage climatisation Ce chiffre sera ajout au diff rentiel du premier tage de fonctionnement Voyez Syst mes deux tages Si le premier tage du syst me s allume trop souvent diminuez cette valeur Ceci allumera le deuxi me tage pour aider le premier tage du syst me Si les deux tages du syst me s allument trop souvent augmentez le r glage de cette valeur pour retarder la mise en route du deuxi me tage de fonctionnement Wee LJ dL D lai de second tage de fonctionnement Cette temporisation commence quand le premier tage de l quipement se met en route Elle se remet z ro quand le premier tage de l quipement s arr te Si cette temporisation arrive terme le deuxi me tage s allumera voyez Syst mes deux tages 20 dLE2 D lai de troisi me tage de fonctionnement Cette temporisation commence quand le second tage de l quipement se met en route Elle se remet z ro quand le second tage de l quipement s arr te Si cette
7. temporisation arrive terme le troisi me tage s allumera Seulement disponible avec le RS4320C Voyez Syst mes trois tages Mat E Auto changeover enable Permet d utiliser le mode d inversion automatique Lorsque ce mode est choisi le thermostat peut faire passer automatiquement du chauffage la climatisation et inversement Notez que les valeurs de r glages HI et LO haute et basse ne sont pas en vigueur en mode d inversion automatique ES db Zone morte pour l inversion automatique correspond au nombre de degr s d cart tol r entre la temp rature de la pi ce et la valeur de r glage avant le d clenchement d un appel de chauffage ou de climatisation Plus la zone morte est grande plus la temp rature ambiante pourra varier Il peut s agir du chaud au froid ou du froid au chaud Uniquement disponible quand l Inversion automatique est activ e J Hi Limite Haute de chauffage C est la valeur maximum de r glage du chauffage L utilisateur ne peut pas programmer une valeur de r glage pour le chauffage plus haute que cette valeur REMARQUE La limite haute de chauffage n est pas en vigueur en mode de transition automatique MH LI Lo Limite Basse de climatisation C est la valeur minimum de r glage de la climatisation L utilisateur ne peut pas programmer une valeur de r glage pour la climatisation plus basse que cette
8. tro clairage Le r tro clairage s teint apr s que 10 secondes se sont coul es sans activit Si le thermostat est c bl de mani re laisser le r tro clairage allum en permanence la lumi re de nuit peut s allumer et s teindre au niveau du menu Arr t automatique Le thermostat n affichera pas la temp rature de la pi ce si la temp rature d passe 37 C 99 F ou descend moins de 0 C 32 F L cran affichera HI ou LO Le thermostat continuera de contr ler le chauffage et la climatisation elle affichera de nouveau les donn es en temps r el une fois que la temp rature ambiante est revenue dans la plage d affichage R glage du ventilateur sur ON AUTO ou CIRC Le ventilateur a 3 r glages On Auto ou Circ Appuyez sur 8 pour passer d un r glage l autre ON Le ventilateur fonctionne constamment Le mode de l quipement de chauffage et de climatisation n a aucun effet sur le ventilateur AUTO Le ventilateur se met en route s il y a un appel de chauffage ou de climatisation CIRC Le ventilateur fonctionne de mani re cyclique en route pendant 10 minutes puis arr t pendant 20 minutes S il y a un appel de chauffage ou de climatisation le cycle est interrompu et le ventilateur r pond l appel Le cycle de circulation reprend quand la demande de chauffage ou de climatisation est satisfaite V rification d pannage Probl me Le thermostat ne met pas le syst me en route Le syst
9. valeur REMARQUE La limite basse de climatisation n est pas en vigueur en mode de transition automatique Lo FL Minuterie pour rappeler au propri taire qu il faut entretenir le filtre Le r glage par d faut est teint Cette minuterie fonctionne quand le syst me est allum et peut tre r gl e sur n teinte ou y activ e Quand il est r gl sur y le rappel de v rification du filtre FL s affiche apr s 1000 heures de fonctionnement Appuyez sur les touches et W pour remettre en route la minuterie du filtre FL n CY Temporisateur de cycle qui permet un compresseur de se reposer entre cycles Cette temporisation peut se r gler de 0 5 minutes par incr ments d une minute g AVERTISSEMENT Un r glage de cycle court incorrect peut endommager votre mat riel Cette valeur ne doit tre modifi e que par un professionnel chauffage climatisation qualifi CL talonnage Modifie la temp rature affich e par rapport la temp rature r elle par 3 3 degr s et par incr ments d un degr Une augmentation de l talonnage de 2 fera afficher par le thermostat une temp rature qui est 2 degr s plus grande que celle de la pi ce ri LL Cr ation d un mot de passe Protection des r glages Les touches sur la face du thermostat peuvent tre verrouill es avec un mot de passe Pour cr er un mot de passe 1 App
10. 320C peut contr ler jusqu trois tages de chauffage et deux tages de climatisation pour les applications avec pompe chaleur Les thermostats RS4000C sont non programmables et fonctionnent avec des valeurs de r glage s par es pour le chauffage et la climatisation A ATTENTION PRECAUTIONS IMPORTANTES A SUIVRE e Coupez toujours l alimentation lectrique au niveau du fusible ou du disjoncteur principal avant d installer de retirer de nettoyer ou de d panner le thermostat e Lisez toute l information de ce manuel avant d installer ce thermostat e l s agit d un thermostat de 24 V c a en basse tension Ne l installez pas si la tension est sup rieure a 30 V c a e Tout le c blage doit se faire en conformit avec les r glements et codes de construction et les r glements et codes lectriques en vigueur e Ne court circuitez pas avec un cavalier les bornes au niveau du robinet de gaz ou du contr le du syst me pour v rifier l installation Ceci endommagera le thermostat et annulera la garantie e Ne mettez aucune des bornes de ce dispositif la masse e Ce thermostat est configur avec une protection automatique du compresseur pour emp cher les d g ts en raison d un cycle court ou de coupures de courant prolong es La protection contre les cycles courts fournit un d lai entre les cycles de chauffage et de climatisation pour les pompes chaleur Des instructions d taill es pour la pose et le c blag
11. E VERS LE HAUT Augmente la valeur de r glage ou de l l ment qui clignote FL CHE VERS LE BAS Diminue la valeur de r glage ou de l l ment qui clignote CHAUFFAGE CLIMATISATION HEAT COOL Permet de passer de l arr t au chauffage a la Climatisation et au mode automatique OFF HEATING COOLING AUTO S il est configur comme thermopompe HP le chauffage d urgence est galement affich Modification des valeurs de l utilisateur Quand vous appuyez en m me temps sur amp et W le thermostat affiche les r glages actuels dans l ordre Pour changer un r glage Quand la valeur est visible et clignote appuyez sur les fl ches ou W pour modifier le chiffre affich SC Echelle F Fahrenheit ou C Celsius Lx bL Le r tro clairage de l cran est toujours allum y ou teint n On l appelle aussi veilleuse ou lumi re de nuit nighlight Si le thermostat a t c bl sous 24 V c a bornes R et C ce dispositif sera affich et son r glage peut tre chang n dF Le diff rentiel emp che le thermostat de s allumer pour de petits changements de temp rature En Fahrenheit il s agit d une plage de 0 5 3 0 degr s En Celsius il s agit d une plage de 0 5 1 5 degr s Le r glage d usine du diff rentiel est de 0 5 C 1 F Ceci signifie que chaque fois que la temp rature ambiante s carte par plus de 0 5 C 1 F de la
12. RS4220C RS4320C 352 00058 001 Rev B USERS MANUAL 28 gt e Thank you for purchasing a Robertshaw RS4000C thermostat This user s manual will guide you through the setup of the RS4220C two stage and the RS4320C three stage thermostats The thermostat should already be mounted and correctly wired The default settings will enable the thermostat to operate efficiently Features e Pop Up Wizard e Automatic changeover e Circulating Fan e Worry Free memory retention e Easy change battery e Large back lit display e Filter change reminder e Low battery indicator e Fahrenheit and Celsius displays e Dual power e Adjustable 1 stage temperature differential 0 5 F to 3 0 F 0 5 C to 1 5 C e Accuracy within 1 F e Universal staging on multi stage units e Automatic heating shutdown if temperature exceeds 99 F 37 C e Keypad security lockout e User settable Hi and Lo temperature limits Three stage heating available for heat pump applications only 1 Application The Robertshaw RS4000C family of thermostats is designed to control gas electric oil heat pump and millivolt heating and electric cooling systems The RS4220C is a two stage thermostat The RS4320C can support three stages of heating and two stages of cooling in heat pump applications The RS4000C thermostats are non programmable and operate on separate heating and cooling setpoints A IMPORTANT SAFETY INFORMATION WARNING
13. a suite d une utilisation incorrecte de n gligence d une mauvaise manipulation de modifications d une installation incorrecte ou d une utilisation non conforme aux recommandations et instructions de Invensys Controls Invensys Controls accepte de r parer ou de remplacer sa discr tion tout thermostat sous garantie condition que celui ci soit retourn pendant la p riode de garantie port pay avec un justificatif de la date d achat Invensys Controls n est pas responsable du co t de la d pose et de la repose du thermostat La r paration ou le remplacement pr vus par cette garantie constituent le seul rem de pour le consommateur Invensys Controls ne sera pas responsable des d g ts secondaires ou cons quents caus s par la rupture de toute garantie expresse ou implicite pour ce produit nine sera responsable sous aucune autre th orie de responsabilit Dans la mesure des lois applicables toute garantie ou condition tacite d aptitude de ce produit tre vendu ou utilis dans un but particulier est limit e la dur e de cette garantie Certaines juridictions ne permettent pas l exclusion ou la limitation des dommages incidents ou cons cutifs ou ne permettent pas de limitations quant la dur e d une garantie par cons quent les limitations ou exclusions d crites ci dessus pourraient ne pas s appliquer dans votre cas Cette garantie vous octroie des droits l gaux sp cifiques Vous pouvez galement b n ficier
14. controls the 3rd stage cycle This time delay starts when the second stage turns on Backlit Display This thermostat is equipped with a backlight to make viewing the display easy Press the button to activate the backlight The backlight will turn off after 10 seconds of inactivity If the thermostat is wired to have the backlight stay on all the time the night light can be turned on off in the settings menu Automatic Shut Down The thermostat will not display the room temperature if the temperature goes higher than 99 F 37 C or lower than 32 F 0 C The display will show HI or LO The thermostat continues to control heating and cooling and will resume the display of real time information when the room temperature is back inside the display s range Setting The Fan To ON AUTO or CIRC The fan has 3 settings On Auto or Circ Press the button to switch among the three ON The fan is on constantly The status of the heating cooling equipment has no effect on the fan AUTO Whenever there is a call for heating or cooling the fan will turn on CIRC The fan operates in a cycle of on for 10 minutes and off for 20 minutes Whenever there is a call for heating or cooling the cycle stops and the fan responds to the call The fan circulation resumes when the call for heating or cooling is satisfied Troubleshooting BC CCE Thermostat does not turn on system System turns on too often System fan does not operat
15. e Always turn off power at main fuse or circuit breaker panel before installing removing cleaning or servicing thermostat e Read all the information in this manual before installing this thermostat e This is a 24V AC low voltage thermostat Do not install on voltages higher than 30V AC e All wiring must conform to local and national building and electrical codes and ordinances e Do not short jumper across terminals on the gas valve or at the system control to test installation This will damage the thermostat and void the warranty e Do not connect ground to any terminal in this unit e This thermostat is configured with automatic compressor protection to prevent damage because of short cycling or extended power outages Short cycle protection provides a delay between heating and cooling cycles on heat pumps Detailed mounting and wiring instructions are explained in the Installation Manual Refer to the pop up wizard section in the installation manual for a complete list of factory defaults and contractor settings Providing Power to the Thermostat For wiring diagrams refer to the Installation Manual The thermostats will operate using 24V AC or two AA batteries When the two AA batteries are installed the thermostat will continue to run if the 24V AC fails Installing or Changing the Batteries To remove the battery compartment gently squeeze the ribbed edges on both sides The battery compartment will pull down
16. e manuel de l utilisateur vous servira de guide pour le r glage des thermostats RS4220C pour deux tages d quipement et du RS4320C pour trois tages d quipement Le thermostat devrait d j tre mont et correctement c bl Les r glages par d faut permettront au thermostat de fonctionner efficacement Caract ristiques e Guide intelligent e Transition automatique e Ventilateur de circulation e Pr servation de la m moire sans tracas e Remplacement facile de la pile e Grand cran d affichage r tro clair e Rappel de changement de filtre e Indicateur de d charge de la pile e Affichage en Centigrade ou en Fahrenheit e Alimentation double e Diff rentiel de temp rature de 1er tage ou niveau de fonctionnement r glable 0 5 C 1 5 C 0 5 F 3 F e Exacta 0 5 C e Etagement universel pour le mat riel multi tag e Arr t automatique du chauffage si la temp rature d passe 37 C 99 F e Verrouillage s curitaire du clavier e Limites de temp ratures haute et basse r glables par l utilisateur Les trois niveaux de fonctionnement ne concernent que les applications avec pompe chaleur Application La gamme de thermostats Robertshaw 4000C est con ue pour contr ler les syst mes de chauffage au gaz lectriques au p trole avec pompes chaleur le chauffage au millivolt et les syst mes de climatisation lectriques Le RS4220C est un thermostat pour deux tages d quipement Le RS4
17. e properly Thermostat does not display proper room temperature Display Shows HI or LO and room temperature is normal Check wiring See Wiring Diagrams section Increase temperature differential See Changing Scale Clock Mode Differential Filter Hours Short Cycle or Offset section Move fan option switch to either gas or electric to match system See Switch Locations section Check F C Fahrenheit Celsius setting See Changing Scale or Calibration section Call a licensed service person to replace repair If problems with thermostat cannot be resolved call www invensyscontrols com or Technical Support 800 445 8299 Five Year Limited Warranty Invensys Controls warrants to the original contractor installer or to the original consumer user each new Robertshaw thermostat to be free from defects in materials and workmanship under normal use and service for a period of Five 5 years from date of purchase This warranty and our liability does not apply to batteries or merchandise that has been damaged by misuse neglect mishandling alterations improper installation or use in a way other than in accordance with Invensys Controls recommendations and instructions Invensys Controls agrees to repair or replace at its option any thermostat under warranty provided it is returned within the warranty period postage prepaid with proof of the date of purchase Cost of thermostat removal or reinstallatio
18. e sont fournies dans le manuel d installation R f rez vous la section sur le guide intelligent dans le manuel d installation pour la liste compl te des r glages d usine et d entrepreneur Alimentation lectrique du thermostat R f rez vous au manuel d installation pour les sch mas de c blage Les thermostats fonctionneront sur 24V c a ou avec deux piles de format AA Si les deux piles AA sont install es le thermostat continuera de fonctionner m me si l alimentation en 24 V c a est coup e Installation ou remplacement des piles Pour retirer le compartiment des piles resserrez doucement les bords c tel s Le compartiment des piles s abaissera du corps du thermostat et s en d tachera Placez y deux piles de type AA en respectant la polarit indiqu e l int rieur du compartiment Remettez le compartiment dans le thermostat Lorsque les piles seront presque d charg es le thermostat se mettra en mode de pile d charg e Ce mode a deux niveaux e NIVEAU 1 L ic ne de la pile d charg e est affich e Le thermostat continuera fonctionner Changez les piles aussit t que possible e NIVEAU 2 L ic ne de la pile d charg e clignote S I l Avec une alimentation de 24 V c a le thermostat continuera de fonctionner m me si les piles sont I s d charg es ou retir es Sans alimentation de 24 V c a le thermostat fonctionne seulement sur les piles et LE SYST ME NE FONCTIONNERA PAS
19. from the thermostat body and will detach Install two AA batteries following the polarity as shown inside the compartment Place compartment back into the thermostat When the batteries are low the thermostat will enter a low battery mode Low battery mode has two levels e LEVEL 1 The low battery icon will be displayed The thermostat will continue to operate Replace Na the batteries as soon as possible e LEVEL 2 The low battery icon will flash If 24V AC is present the thermostat will continue to operate if D l l the batteries are discharged or removed If 24V AC is not present the thermostat runs on batteries only I s and THE SYSTEM WILL NOT OPERATE Replace batteries immediately Replace batteries if leaving thermostat unattended for more than 30 days Display Description The thermostat display will show information that is being used during operation or programming This illustration shows all of the display s possibilities with an explanation 8 N N SETAT 00 ge See CI x TS AUTO 4 api 117 am a EE 7 6 Used with setpoint 2 Used for current setpoint and some configuration data 3 HVAC mode and status Icons blink when active Ais for Auto 2 is for second stage E is for emergency Both the 2 and E will be displayed when 3rd stage heat is active Indicates when security is active Low battery indicator Used for ambient temperature and configu
20. h To unlock the buttons 1 Push and hold the amp and buttons for 5 seconds until the request for password is displayed 2 Enter the digits for the password by pressing amp or W to progress through the numbers to the password 3 When the correct password is set wait for 5 seconds to unlock the system 4 If the wrong password is entered the display will flash for 5 seconds then return to normal Once the security has been disabled a password needs to be re created to protect the settings Two Stage Systems will provide extra heating or cooling When a 2nd stage is operating the display will show the sof g number 2 by the heat cool icons Ven 6 A 2nd stage is a second or additional system that SET AT A temperature differential default value is 2 0 F or 1 0 C and time delay default value 20 minutes control the 2nd stage cycle Operation of the 2nd stage begins when e The room temperature changes from the setpoint by the sum of the 1st and 2nd stage differential settings e The first stage has been on for the specified delay time but the heating cooling demand has not yet been met Three Stage Systems A 3rd stage is a third or additional system that will SETAT provide extra heating in heat pump applications When a 3rd stage is operating the display will E4 A 6 show the number 2 and E by the heat icon 36 en A time delay default value 20 minutes
21. hauffage Inversion automatique L inversion automatique Auto Changeover est la capacit du thermostat de commuter automatiquement entre les r glages de chauffage et les r glages de climatisation C est utile au printemps et en automne quand il fait chaud pendant le jour mais froid la nuit En mode de chauffage si la pi ce continue chauffer au del d un seuil d termin le thermostat passe au mode de climatisation avec les r glages de climatisation associ s Et inversement mesure que la temp rature de la pi ce change le thermostat demande du chauffage ou de la climatisation selon le besoin Pour emp cher le chevauchement du chauffage et de la climatisation il faut une plage de transition automatique appel e zone morte deadband La zone morte est le changement de temp rature minimum n cessaire pour passer du chauffage la climatisation et inversement Plus la zone morte est grande plus la temp rature ambiante pourra varier Utilisation du thermostat N importe quel r glage peut tre chang quand il clignote en appuyant sur amp ou Y Si vous n appuyez sur aucune touche pendant 10 secondes le thermostat revient au fonctionnement normal Les touches suivantes sont accessibles sur la face du panneau BARRE DE LUMI RE LIGHT BAR Allume le r tro clairage de l cran pendant 10 secondes VENTILATEUR FAN Met le ventilateur sur AUTOMATIQUE CIRCULATION ou en MARCHE FL CH
22. hen the first stage turns on It resets when the first stage turns off If this timer runs out the second stage will turn on See Two Stage Systems ot dL E2 Third Stage Delay This timer starts when the second stage turns on It resets when the second stage turns off If this timer runs out the third stage will turn on Available on RS4320C only See Three Stage Systems Mat E Auto changeover enable Makes the auto changeover mode available When chosen the user can select auto changeover mode which automatically switches between heating and cooling Note that the High and Low setpoint limits are not enforced in auto changeover mode db Deadband for auto changeover the number of degrees that the room temperature can move away from the active setpoint until heating or cooling is called for The larger the deadband the more the room temperature will vary This can be from heat to cool or cool to heat Available only when auto changeover is enabled J Hi High Heat Limit This is the highest allowed heating setpoint The user will not be allowed to set a heating setpoint higher than this value Note High Heat Limit is not enforced in auto changover mode Lo Low Cool Limit This is the lowest allowed cooling setpoint The user will not be allowed to set a cooling setpoint lower than this value Note Low Cool Limit is not enforced in auto changover mode
23. m e Le diff rentiel de premier tage est de 1 F Le diff rentiel de second tage RS4220C est de 2 F Le d lai de second tage de fonctionnement est de 20 minutes Le d lai de troisi me tage de fonctionnement RS4320C est de 20 minutes Inversion automatique activ e La zone morte de l Inversion automatique est de 3 F Le rappel de la dur e d utilisation du filtre est teint Le d calage de la temp rature est de 0 degr s La limite haute HI pour le chauffage est 32 C 90 F La limite basse LO de la climatisation est 7 C 45 F Le mode de fonctionnement est TEINT La valeur du ventilateur est Auto Le clavier n a pas de protection par mot de passe R f rez vous la section sur le guide intelligent dans le manuel d installation pour la liste compl te des r glages d usine et d entrepreneur Chauffage d urgence Votre syst me peut comprendre un chauffage d urgence Emergency Heat Les thermostats RS4220C et RS4320C ont une capacit de chauffage d urgence pour les syst mes multi tag s avec thermopompe Pour savoir si votre syst me est capable d utiliser le chauffage d urgence contactez votre entrepreneur Utilisez la touche amp pour acc der au mode d urgence EMER Un E sera affich avec le symbole du chauffage Ce mode est employ pour contourner la pompe chaleur quand elle a besoin d entretien ou quand elle ne peut pas r pondre la demande de c
24. n is not the responsibility of Invensys Controls Repair or replacement as provided under this warranty is the exclusive remedy of the consumer Invensys Controls shall not be liable for any incidental or consequential damages for breach of any express or implied warranty on this product or under any other theory of liability Except to the extent prohibited by applicable law any implied warranty of merchantability or fitness for a particular purpose on this product is limited to the duration of this warranty Some states do not allow the exclusion or limitation of incidental or consequential damages or allow limitations on how long an implied warranty lasts so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state For warranty returns send thermostat shipping prepaid to Invensys Controls Warranty Claims Department 515 S Promenade Corona CA 91719 In Canada Invensys Controls 3505 Laird Road Unit 14 Mississauga Ontarion L5L 5Y7 Canada Attn Warranty Department NOTES Invensys Controls 515 South Promenade Avenue Corona CA 92879 1736 United States of America www invensyscontrols com 2008 Invensys Controls 2 08 352 00058 001 Rev B RS4220C RS4320C 352 00058 001 Rev B MANUEL DE LUTILISATEUR CO SNS ANR yt 00e Roth Merci pour votre achat d un thermostat programmable Robertshaw RS4000C C
25. ny setting When the setting is visible and flashing press the am or Y arrows to adjust the number on the screen SC Scale in F Fahrenheit or C Celsius Lx bL Display backlight always on y or off n Also called the nightlight feature If the thermostat has been wired with 24V AC R and C terminals then this feature will be displayed and the setting can be changed n dF The differential keeps the thermostat from turning on for small changes in temperature When in Fahrenheit the range is 0 5 to 3 0 Degrees In Celsius the range is 0 5 to 1 5 Degrees The differential is factory set at 1 0 F 0 5 C This means that whenever the room temperature is more than 1 F 0 5 C different from the set temperature the system will turn on If the system is turning on too often increase the differential setting Note that a larger differential will mean the room temperature changes more before the system turns on TRE J d2 Second Stage Differential Operates with the first stage to control a second heating cooling system This number will be added to the first stage differential See Two Stage Systems If the first stage is running too often lower the settings This will turn the second stage on to help the first stage If both stages are coming on too often then increase this setting to delay the second stage Wee Ls dL Second Stage Delay This timer starts w
26. r is the ability of the thermostat to switch automatically between heating settings and cooling settings This is useful in Spring and Fall when the days are warm and the nights are cool In heat mode if the room continues to warm beyond a set threshold the thermostat switches to the cool mode and the associated cooling settings The reverse is also true As the room temperature changes the thermostat will call for heating or cooling as needed To prevent the heating and cooling systems from overriding each other an auto changeover deadband is used The deadband is the minimum temperature swing before changing from heating to cooling or vice versa The larger the deadband the more the room temperature will vary Operating the Thermostat Any setting can be changed when it is flashing by pushing amp or W If a button is not pushed for 10 seconds the thermostat returns to operation The following buttons can be accessed from the front panel E LIGHT BAR Turns on the display back light for 10 seconds FAN Turns fan to AUTOMATIC CIRCULATE or ON UP ARROW Raises the setpoint or increases flashing item DOWN ARROW Lowers the setpoint or decreases flashing item HEAT COOL Toggles through OFF HEATING COOLING and AUTO If configured as HP then emergency heat is also displayed Changing the User Settings When amp and W are pressed at the same time the thermostat will display the current settings in order To change a
27. ration data e g first stage differential F or C etc 7 Fan status rotates when active 8 Fan mode selected by pressing FAN button ans User Settings Defaults During any program changes the display returns back to the operating display if a button has not been pushed in 10 seconds The temperature scale is set to Fahrenheit Night light is on The first stage differential is 1 F The second stage differential RS4220C is 2 F The second stage delay is 20 minutes Third stage delay RS4320C is 20 minutes Auto changeover is enabled Auto changeover deadband is 3 F Filter reminder length is off Temperature offset is 0 degrees The HI heat limit is 90 F 32 C The LO cool limit is 45 F 7 C The operation mode is OFF The fan setting is Auto The keypad has no password protection Refer to the Pop Up Wizard section in the installation manual for a complete list of factory defaults and contractor settings Emergency Heat Your system may include Emergency Heat The RS4220C and RS4320C thermostats have an emergency heat capability for multi stage heat pump systems To determine if your system is capable of using emergency heat contact your contractor Use the button to enter the EMER mode An E will be displayed with the Heat symbol This mode is used to bypass the heat pump when it needs servicing or when it cannot keep up with the heat demand Auto Changeover Auto changeove
28. uyez simultan ment sur les touches et 6 et maintenez les enfonc es pendant 5 secondes On vous demandera un mot de passe de 2 chiffres 2 Les chiffres sont programm s avec les touches amp et W qui permettent d aller de 00 a 99 Appuyez sur CE pour passer au chiffre suivant Appuyez sur 8 pour revenir en arri re 3 Le mot de passe est enregistr apr s 5 secondes Toutes les touches sur la face du thermostat sont maintenant verrouill es jusqu ce que le mot de passe soit entr 8 Lorsqu on appuie sur n importe quelle touche amp se met clignoter Pour d bloquer les touches 1 Maintenez enfonc es les touches et 4 pendant 5 secondes jusqu ce que la demande du mot de passe s affiche 2 Entrez les chiffres du mot de passe en appuyant sur les touches s et W ou pour faire d filer les chiffres jusqu ceux du mot de passe 3 Une fois que le mot de passe correct est entr le syst me se d verrouille apr s un d lai de 5 secondes 4 Sile mot de passe entr est incorrect l cran affichera et fera clignoter pendant 5 secondes puis reviendra la normale Une fois que le syst me de s curit a t neutralis il faut recr er un mot de passe pour prot ger les r glages Syst mes deux tages d quipement Un second tage d quipement est un deuxi me syst me ou un syst me suppl mentaire qui r SETAT fournira du chauffage ou de la climatisation l suppl mentaire Quand un

Download Pdf Manuals

image

Related Search

Related Contents

User`s Manual of Small Pressure Sensor (VUS12 Series)  Dixon Zeeter 14295-0804 User's Manual  除雪機の取扱いに注意![PDF:355KB]  Modo de empleo TNC 122  OCI55  User Guide - Mining Mart  SCP 12000 Level Sensor SDP 14000 Level Sensor  Ricerca guasti del server  Home Legend HL9312NH Installation Guide  Dragon Ball Z The Legend (Saturn)  