Regency L900E-NG User's Manual
Contents
1. 42 WARRANTY The Warranty Limited Lifetime rronnrnnnnrrnnnrnnanennnre 43 SAFETY LABEL This is a copy of the label that accompanies each LOO00E NG and L900E LP Direct Vent DO NOT REMOVE THIS LABEL NE PAS ENLEVER CETTE ETIQUETTE Gas Fireplace We have printed a copy of the contents here for your review The safety label REGENCY 322 is located on the right hand side of the unit FIREPLACE FPRSDESTE Serial No No de serie H visible when the exterior right side brick panel Listed VENTED GAS FIREPLACE lt q is removed Tested to ANSI Z21 88 2005 CSA 2 33 2005 CAN CGA 2 17 M91 ANSI Z21 50 2003 CSA 2 22 2003 ANSI Z21 50A 2003 lt NOTE Regency units are constantly being 122 CSA 2 22A 2003 ANSI Z21 50B 2003 CSA Z22b 2003 m improved Check the label on the unit and if ie Certified for Certifi e pour CANADA AND U S A gt there is a difference the label on the unit is the correct one NATURAL GAS FIREPLACE MODEL L900E NG Factory Equipped For Altitude 0 4500ft 0 1372m rs Min Supply Pressure 5 WC 1 25 kpa Low Setting Man Pressure 1 6 WC 0 39 kpa Max Manifold Pressure 3 5 WC 0 87 kpa 6 5 Orifice Size Front Burner HAT DMS Orifice Size Back Burner 30 DMS f Minimum Input 11 000 Btu h 3 22 kW Maximum Input 48 000 Btu h 14 06 kW PROPANE GAS FIREPLACE MODEL L900E LP O Factory Equipped For Altitude 0 4500ft 0 137
2. FIREPLACE PRODUCTS REGENCY www regency fire com LIBERTY L900E Gas Fireplace Owners amp Installation Manual Unit requires 120V to operate See Wiring Diagram section in manual for more details Receptacle is included RR with manual _ eva WARNING Ifthe information in these instructions are not followed exactly What to do if you smell gas a fire or explosion may result causing property damage Do not try to light any appliance personal injury or loss of life Do not touch any electrical switch do not use any phone in your FOR YOUR SAFETY building Do not store or use gasoline or other flammable vapors and Immediately call your gas supplier liquids in the vicinity of this or any other appliance from a neighbour s phone Follow the gas supplier s instructions Installation and service must be performed by a qualified If you cannot reach your gas installer service agency or the gas supplier supplier call the fire department Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference 918 623a FPI FIREPLACE PRODUCTS INTERNATIONAL LTD 6988 Venture St Delta BC Canada V4G 1H4 01 07 08 To the New Owner Congratulations You are the owner of a state of the art Gas Fireplace by REGENCY The L900E has been designed to provide you with al
3. Regency L900E Direct Vent Gas Fireplace INSTALLATION 5 X 6 RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed Not All Rigid Pipe components are available directly from FPI Simpson 6 Pipe Length Galvanized 6 Pipe Length Black 9 Pipe Length Galvanized 9 Pipe Length Black 12 Pipe Length Galvanized 12 Pipe Length Black 18 Pipe Length Galvanized 16 Pipe Length Black 24 Pipe Length Galvanized 24 Pipe Length Black 36 Pipe Length Galvanized 36 Pipe Length Black 48 Pipe Length Galvanized 48 Pipe Length Black 60 Pipe Length Galvanized 60 Pipe Length Black Adjustable Length 3 10 Galvanized Adjustable Length 3 10 Black Adjustable Length 11 14 Galvanized Adjustable Length 11 14 Black Adjustable Length 17 24 Galvanized Adjustable Length 177 24 Black Extension Pipe 8 1 2 Galvanized Extension Pipe 8 1 2 Black Extension Pipe 16 Galvanized Extension Pipe 16 Black 45 Elbow Galvanized 45 Elbow Black 45 Elbow Swivel Galvanized 45 Elbow Swivel Black 90 Elbow Galvanized 90 Elbow Black 90 Elbow Swivel Galvanized 90 Elbow Swivel Black 90 Starter Elbow Swivel Galvanized Adaptor Ceiling Support Cathedral Support Box Wall Support Band Offset Support Wall Thimble Black Wall Thimble Support Box Ceiling Support
4. Note When constructing the framed opening please ensure there is access to install the gas lines when the unitis installed See diagram 3 for details 2 For exterior walls insulate the enclosure to the same degree as the rest of the house apply vapour barrier and drywall as per local instal lation codes Do not insulate the fireplace itself 3 The unit does not have to be completely enclosed in chase The clearance on top of the unit from the top standoffs is 0 so combusti ble building materials can be laid directly on top of the standoffs You must maintain clearances from the vent to combustible materials See Clearances section Combustible materials can be laid against the side and back standoffs and the stove base Note When installing this fireplace there are two warnings on the front face of the unit The areas indicated here are painted black and indicate that no nails screws or other punctures can be made at these points as there are sensitive electronic components directly behind these markings Regency L900E Direct Vent Gas Fireplace 11 Z gt E gt Z O x x o Z INSTALLATION UNIT ASSEMBLY PRIOR TO INSTALLATION The Top Facing Support the Side Nailing Strips and the 2 Top Standoffs must be correctly positioned and attached to the top before unit is slipped into position TOP STANDOFF ASSEMBLY The top standoffs are shipped in a flat posit
5. 14 12 10 6 6 4 2 0 Z Note Ensure the paint that is used meer Eser on the mantel and the facing is 13 330mm heat resistant or the paint may discolour 25 Drywall 20 3 89mm Header y sl V On Edge 15 Non combustible 1 25mm Facing 27 1 2 18 1 2 699mm 470mm Standoff 10 17 1 2 445mm 0 Top of 7 Front Facing MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram MANTEL LEG Allowable mantel 11 1 2 292mm leg projection Side wall 10 Regency L900E Direct Vent Gas Fireplace INSTALLATION FRAMING amp FINISHING 1 Frame in the enclosure for the unit with framing material The framed opening for the assembled kit is 50 3 4 high x 52 wide x 26 1 2 deep 1289mm x H 1321mm W x 673mm D See Diagram 1 Also see Diagram 2 for corner installations Header On Edge 83 2108mm Min 26 1 2 673mm 52 1321mm Diagram 1 90 7 16 2286mm gt Diagram 2 Non Combustible Requirements e 53 3 4 1365mm Non combustible Material 10 5 16 254mm Drywall Non Combustible X Material Header iW X VA gt E E LO st x N a A I N rs N N A 76 1930mm v Diagram 3 Q 8 152mm
6. LLI lt 10 Replace the control box 11 Reverse steps 9 to 1 When re connecting wire harnesses Ensure that the cables match the letters labelled on the control box and are securely connected Jumper Cable B DO NOT REMOVE 38 Regency L900E Direct Vent Gas Fireplace MAINTENANGE VALVE TRAY REPLACEMENT 1 Remove the exterior brick panels 3 Loosen the screw that holds the right side 8 Remove the grate by undoing the 2 screws heat shield in place on the right and left side 2 Remove the glass door a Release the 2 door latches on the left and right side at the top of the firebox Mr ED Latch Location Grate Heat Shield 9 Remove the front burner by removing the Latch screw 4 Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket located directly above the heat shield 5 Disconnect both sources of power the power cord located on the left hand side of the firebox and the wires connected to the back up battery located on the right side of the firebox Swing the door outfrom the top andrelease the hinges on the left and right side of the door by lifting them up Backup Battery Door Power Receptacle lt gt Z m Z gt Z O Front Burner Removed Ai 10 Remove the back burner by removing the screw c Place the door on asoftsurface to prevent scratching 6 R
7. RIGID PIPE VENTING SYSTEMS BASIC HORIZONTAL amp VERTICAL TERMINATIONS Rigid Pipe Vent Systems offer a complete line of component parts for installation of both horizontal and vertical installations Many items are offered in decorative black as well as gal vanized finish The minimum components required for a basic horizontal termination are AstroCap XL 90 Elbow Rigid Pipe Adaptor Wall Thimble Length of pipe to suit wall thickness _ _ The minimum components required for a basic vertical termination are 1 Vertical Termination Cap 1 Rigid Pipe Adaptor 1 Lengths of pipe to adequately penetrate roof 1 Ceiling Firestop 1 Flashing 1 Storm Collar Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap For siding other than vinyl furring strips may be used instead of the vinyl siding standoff to create 8 level surface to mount the vent terminal The Terminal must not be recessed into siding Measure the wall thickness including furring strips If a Vinyl Siding Standoff is required it must be used with vinyl siding measure to outside surface of wall without siding and add 2 inches Alternate Horizontal Termination Caps Alternate Snorkel Termination Cap Part 1282 14 Part 1281 36 Part 5DT ST14 14 Part 5DT ST36 36 Vertical Terminal e Nun Storm Collar CD Flashing Ceiling Fres gt Vinyl Sid
8. a 03 41 Log Rear b 03 42 Log Front Left c 03 43 Log Front Right d 03 44 Log Cross Left e 03 45 Log Cross Right f 902 154 Embers Lava g 902 179 Vermiculite h 946 669 Platinum Embers supplied with packaged manual 4 Spread some vermiculite on the front log tray next to log 03 42 as shown in the image below Note Do not build up vermiculite as this will cause the next log 03 43 not to sit all the way down Vermiculite is only needed to conceal the metal inbetween the left and right front logs The 03 reference numbers i e 03 41 are molded into the rear of each log 1 Carefully remove the logs from the box and unwrap them The logs are fragile handle with care do not force into position 2 Place log 03 41 on the rear log support pins 30 Regency L900E Direct Vent Gas Fireplace INSTALLATION 5 Place the left end of log 03 43 into the pin while fitting the notch 8 Spread all of the Embers on the bottom brick panel around the burner onto the burner tube Slide the right end of the log forward until it is tube and on the inside of the grate as shown approximately 3 8 away from the back side of the grate Separate platinum embers and place on the embers around the burner tube and on the inside of the grate Avoid stacking platinum embers Z gt E gt 4 Embers on bottom brick panel Burner Tube 6 Line up the two holes on the underside of log 03 44
9. 46 47 48 49 Part 521 015 546 016 546 042 948 459 948 458 546 050 502 061 380 013 W840470 521 007 546 025 910 480 546 547 910 952 910 953 904 617 904 622 904 241 904 641 Description Bracket Log Tray Log Tray Deflector Log Tray Burner Rear NG LP Burner Front NG LP Grate Pilot Shield Pilot Holder Gasket Pilot Assembly Valve Tray Valve Bracket Valve 845 SIT Electric Valve Tray Assembly Pilot Assembly NG Pilot Assembly LP NG Orifice 430 NG Orifice 47 LP Orifice 456 LP Orifice 450 Part 910 937 546 930 546 935 910 960 918 619 BURNER amp LOG ASSEMBLY Description Valve Solenoid Birch Log Set Oak Log Set FireWizard Remote Control Manual FireWizard E 42 Regency L900E Direct Vent Gas Fireplace WARRANTY REGENCY Regency Fireplace Products are designed with reliability and simplicity in mind In addition our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility FPI Fireplace Products International Ltd is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product This warranty is not transferable The Warranty Limited Lifetime The combustion chamber heat exchanger burner tubes logs brick panels against defective manufacture only are covered under the Limited Lifetime Warranty for five 5 years for parts and sub
10. Corner C Recessed into Wall Alcove Corner Diagram 1 4 This appliance is Listed for bedroom installations using the standard FireWizard Remote millivolt thermostat system Some areas may have further requirements check local codes before installation 5 The L900E Direct Vent Gas Fireplace is approved for alcove installations see Clearances section for details 6 We recommend that you plan your installation on paper using exact measurements for clearances and floor protection before actually installing this appliance Have an authorized inspector dealer or installer review your plans before installation Note For vent terminations refer to Exterior Vent Termination Locations section HEATWAVE DUCT KIT The HeatWave Air Duct Kit increases the effectiveness of your fireplace by dispersing warm air from the fireplace to remote locations in the same room or other rooms in your home Up to two kits may be installed on the fireplace Please Note Only 1 HeatWave kit may be operated at one time See HeatWave installation manual for complete details and clearances from side only Heat Wave gt The HeatWave Duct Kit has different clearance and framing requirements check the HeatWave manual for details HEAT RELEASE KIT The Heat Release Kit expels warm air from the fireplace to the outside of the building allowing the fireplace to be operated with less heat entering t
11. N A N A N A 5DT EL45 N A 5DT EL45B N A N A 5D45L N A 5D45LB 5DT EL90S N A 5DT EL90SB N A N A 5D90L N A 5D90LB N A 5D90A N A SDDA SDT CS SDT CSS SDT WS B SDT OS SDT WT N A SDT FS SDT TP 17 INSTALLATION Components from different Manufacturers may not be mixed Not All Rigid Pipe components are available directly from FPI Simpson EE Simpson 5 Selkirk Metal Fab Descri ption Direct Vent Pro Der Direct Temp Sure Seal Discontinued Round Support Radiation Sheild N A N A N A N A Flat Flashing N A N A N A N A Attic Insulation Shield 12 58DVA IS N A from FP 58DVA IS N A from FPI Basic Horizontal Termination Kit A N A 5DT HKA Horizontal Termination Kit B 58DVA KHA 5DT HKB Vertical Termination Kit 58DVA VCH 5DT VKC O x x ep Z High Wind Vertical Cap N A N A High Wind Horizontal Cap DISC N A Horizontal Square Termination Cap N A 5DT HHC Vertical Termination Cap N A 5DT HVC Storm Collar 58DVA SC 5DT SC Adjustable Flashing 0 12 6 12 58DVA F6 1243 5DT AF6 5DE Adjustable Flashing 6 12 12 12 58DVA F12 1243S 5DT AF12 5DF 12 Vinyl Siding Standoff 58DVA VSS 1250 5DT VS 5DVS Vinyl Siding Shield Plate N A N A 5DT VSP N A Snorkel Termination 14 58DVA SNK14 1282 5DT ST14 5DST14 Snorkel Termination 36 N A 1281 5DT ST36 5DST36 Restrictor Disk 58DVA RD N A N A N A Colinear Flex Liner Adapter 3 N A N A N A N A FPI 946 604 P Simpson Direc
12. Remove any bird nests or other foreign material 3 Check for evidences of excessive condensation such as water droplets forming in the inner liner and subsequently dripping out the joints Continuous condensation can cause corrosion of caps pipe and fittings It may be caused by having excessive lateral runs too many elbows and exterior portions of the system being exposed to cold weather 4 Inspect joints to verify that no pipe sections or fittings have been disturbed and consequently loosened Also check mechanical supports such as Wall Straps or plumbers tape for rigidity LOG REPLACEMENT The unit should never be used with broken logs Turn off the unit and allow the unit to cool before opening door and carefully remove the logs If for any reason a log should need replacement you must use the proper replacement log The position of these logs must be as shown in the diagrams under Log Installation Note Improper positioning of logs may create carbon build up and will severely alter the unit s performance which is not covered under warranty GLASS GASKET If the glass gasket requires replacement use a tadpole glass gasket Part 936 155 DOOR GLASS Your Regency fireplace is supplied with high temperature 5mm Ceramic glass If your glass requires cleaning we recommend using an approved glass cleaner available at all authorized dealers Do not use abrasive materials CAUTION amp WARNINGS Do n
13. Venting Arrangements cccccseeeceeeeeseeeeeeeeeeeeeeeaaees 15 Horizontal Termination 15 Rigid Pipe Venting Systems rrrrnnnnnnrrnnnnrrnnnrennnnnen 16 Basic Horizontal amp Vertical Terminations 16 5 x 8 Rigid Pipe Cross Reference Chart 17 Venting Arrangements ccccseeeceeeeseeeeeeeeeeaeeeenaees 19 Allowable Horizontal Terminations 06 19 Venting Arrangements ccccseeecceeeeseeeeeeeeeeeeeeeaaees 22 Allowable Vertical Terminations 00008 22 Unit Installation with Horizontal Termination 23 Unit Installation with Vertical Termination 24 Horizontal Termination with Flex Vent System 25 Regency L900E Direct Vent Gas Fireplace TABLE OF CONTENTS HOM EIGV ALON eee 26 Gas Line Installation 555555555055550555505559005599555 59 26 NOU AGUS WIIG IN oases eset tse cases 26 Gas Pipe Pressure Testing cccccseceseeeceeeeeeeeeeeees 26 SIT 845 Valve Description rrrarenrnrrnnnnenrnnrnrnnnrvnnnennn 26 Aeration Adjustment 5 55 5555555555595555 26 Back Up Battery Installation rrorororrrnnrrrarrrnnrrnnnrnn 27 Brick Panel Installation 555 5555 555505555555505559555 5 28 Log Set 518 8
14. all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment all venting instructions all parts lists for venting instructions and or all venting design instructions shall remain with the appliance or equipment at the completion of the installation Regency L900E Direct Vent Gas Fireplace 5 UNIT DIMENSIONS O x x ep Z 51 1 2 1308mm 5 127mm Inner Dia 8 203mm Outer Dia T F E Al 3 7 Q 1 il H 51mm 33 1 8 838mm 6 Regency L900E Direct Vent Gas Fireplace IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The L900E Direct Vent Fireplace must be installed in accordance with these instructions Carefully read all the instructions in this manual first Consult the authority having jurisdiction to determine the need for a permit prior to starting the installation It is the responsibility of the installer to ensure this fireplace is installed in compliance with manufacturers instructions and all applicable codes BEFORE YOU START Safe installation and operation of this appliance requires common sense however we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSO
15. is perfectly normal due to the fact that there are various gauges and types of steel used within your appliance Listed below are some examples All are normal operating sounds and should not be considered as defects in your appliance Burner Tray The burner tray is positioned directly under the burner tube and logs and is made of a different gauge material from the rest of the firebox and body Therefore the varying thicknesses of steel will expand and contract at slightly different rates which can cause ticking and cracking sounds You should also be aware that as there are temperature changes within the unit these sounds will likely re occur Again this is normal for steel fireboxes Pilot Flame While the pilot flame is on it can make a very slight whisper sound Gas Control Valve As the gas control valve turns ON and OFF a dull clicking sound may be audible this is normal operation of a gas regulator or valve Unit Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process OPERATION DURING POWER OUTAGE In the event of a power failure the unit will be fully functional for the first 45 minutes using the backup battery system If power resumes within the first 45 minutes you can continue using the unit as normal If power is restored after 45 minutes you will need to rese
16. screws Vinyl siding standoff Wall Thimble required Diagram 5 The four wood screws provided should be re placed with appropriate fasteners for stucco brick concrete or other types of sidings Before connecting the horizontal run of vent pipe to the vent termination slide the Wall Thimble over the vent pipe The wall thimble is required for all horizontal terminations Slide the appliance and vent assembly towards the wall carefully inserting the vent pipe into the vent cap assembly Itis important that the vent pipe extends into the vent cap sufficient distance so as to result in 8 minimum pipe overlap of 1 1 4 inches 32mm Secure the connection between the vent pipe and the vent cap 10 Install wall thimble in the center of the 11 279mm square and attach with wood screws Diagram 7 wood screws gt Diagram 7 NOTE A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower 23 Z gt gt Z INSTALLATION UNIT INSTALLATION 4 Assemble the desired lengths of pipe and elbows Ensure that all pipes and elbow WITH VERTICAL connections are in the fully twist locked position and sealed TERMINATION Note pr Rig id Vent Sy stems For best results and optimum performance Note clearance of 2 51mm must be with each approved venting system it is lt ma
17. to PT en EE NO EN z 3 E 4 gt 2 0 y e Vent must be supported at offsets e Firestops are required at each floor level and whenever passing through a wall e Maintain clearances to combustibles as listed in the Clearances section e Refer to Vent Restrictor Position section for details on how to change the vent restrictor to Set 1 Set 2 or Set 3 if required Note Must use optional flue adapter when using Rigid Pipe Part 770 994 22 Regency L900E Direct Vent Gas Fireplace INSTALLATION Horizontal runs of vent must be supported every 3 feet 0 9meter Wall straps are available for this purpose UNIT INSTALLATION WITH HORIZONTAL TERMINATION Rigid Vent Systems 6 Mark the wall for a 11 x 11 279mm x 279mm square hole The center of the square hole should line up with the center line of the horizontal pipe Cut and frame the 11 inch 279mm square hole in the exterior wall where the vent will be terminated See diagram 2 for center line requirements Atop clearance of 3 76mm and side amp bottom clearance of 2 51mm must be maintained except when passing through a wall ceil ing or at the termination where the use of a firestop or wall thimble reduces the required clearance to 1 1 2 38mm We recommend framing a 11 279mm x 11 279mm inside dimensions hole to give structural rigidity for mounting the termination If the wall being penetrated is cons
18. warranty policy Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy The warranty will not extend to any part which has been tampered with or altered in any way or in our judgment has been subject to misuse improper installation negligence or accident spillage or downdrafts caused by environmental or geographical conditions inadequate ventilation excessive offsets negative air pressure caused by mechanical systems such as furnaces fans clothes dryer etc Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer FPI will not be liable for acts of God or acts of terrorism which cause malfunction of the appliance Performance problems due to operator error will not be covered by this warranty policy Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI may nullify your warranty on this product Any alteration to the unit which causes sooting or carboning that results in damage to the interior exterior facia is not the responsibility of FPI Subsidy according to job scale as predetermined by FPI Regency L900E Direct Vent Gas Fireplace 43 FPI fireplaces are designed with reliability and simplicity in mind In addition our internal Quality Assurance Team carefully inspects each unit thoroughl
19. with the pins on logs 03 41 and 03 42 and fit in place Embers on inside of grate 9 Spreadthe vermiculite on the base brick panel covering the remaining exposed base brick 7 Line up the two holes on the underside of log 03 45 with the pins on logs 03 41 and 03 43 and fit in place Regency L900E Direct Vent Gas Fireplace 31 O x x ep Z INSTALLATION WIRING DIAGRAM Lockout Led Reset Button ECS MODULE 120V Power Source NEUTRAL white MODULATING g COIL EMBER REAR SECONDARY MAIN BURNER BURNER ROC N ME EO Ii EVI Ev2 D AO ET red Z black 9V SOLENOID VALVE Flame Sensor PILOT Spark Ignitor Areceptacle is provided on the left hand side of the unit 120 Volt AC power Caution Ensure that the wires do not touch any hot must be wired to the receptacle and the control module plugged in for the surfaces and are away from sharp edges unit to operate fully The front and rear burners will operate on low when the unit is running on battery back up CAUTION Label all wires prior to disconnection when Do not cut the ground terminal off under any circumstances servicing controls Wiring errors can cause improper and dangerous operation 32 Regency L900E Direct Vent Gas Fireplace OPERATING INSTRUCTIONS MATCHING REMOTE HANDSET amp CONTROL BOX ID CODE The Remote Control Handset has a set of unique ID co
20. 0 55 0555 055550555505555555555 555 30 VV ITE Biagi AN vamser 32 OPERATING INSTRUCTIONS Matching Remote Handset amp Control Box ID Code 33 Operating Instructions ccccceeeecceeeeceeeeeeeeeeeesees 33 BLE a ree eee ERE eho ote ee ree ge 33 Lighting Procedure rernnnvrnnnernnnnnnnnnnnnnnennnnennnnennnnen 33 Shutdown Procedure m isrsnssmnmnsssnesverdeedsmebdnser danken 33 Normal Operating Sounds of Gas Appliances 34 Operation During Power Outage rrrrnnnnnnnnrnnnnnnnnnennn 34 BACKUP BEATE ae 34 Copy of Lighting Plate Instructions 35 Maintenance Instructions rrronrrrarernrrrnnrrnnrrvnnrvnnnnnn 36 General Vent Maintenance cccccccceeeeeeeeeeeeeeeaes 36 Log Replacement 2 sstesduanenletaavatse ii 36 Glass Giskes 36 MAINTENANCE Biore GIES per 36 Glass Replacement rrannrnnnnonnnnrnnanennanenvanennannnnannenen 36 Back up Battery Replacement ranrnnrnnnnnranrvnnrnnnnnnn 37 Control Box Replacement rrrranennanennnnerrannnrnnnnvnnnennn 37 Valve Tray Replacement rrrannnnnrnnnnnnnnnnnnnvnnrnnnnnnnnnn 39 PARTS LIST Main Assembly 41 Burner amp Log Assembly
21. 149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This appliance comes equipped with a dedicated 8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local codes The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or the Canadian Electrical Code CSA C22 1 This appliance may only be installed in an aftermarket permanently located manufactured U S A only or mobile home where not prohibited by local codes This appliance can only be used with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used Ensure that structural members are not cut or weakened during installation ah ek We recommend that our products be INSTITUTE installed and serviced by professionals who are certified in the U S by the National Fireplace Institute NFI ONE REGENCY ONE TREE For each Regency sold we plant a tree AmericanForests org Technical Training or in Canada by Wood Energy Technical Wood Energy CERTIFIED Training WETT 2 Regency L900E Direct Vent Gas Fireplace SAFETY LABEL Copy of Safety Decale ra 4 REQUIREMENTS MA Code CO Detector for the State of Massachusetts 5 UNIT DIMENSIONS
22. 2m rs Q Min Supply Pressure 12 WC 2 98 kpa Low Setting Man Pressure 3 6 WC 0 9 kpa r Max Manifold Pressure 10 WC 2 49 kpa 1 ee Orifice Size Front Burner 56 DMS lt 23 Orifice Size Back Burner 50 DMS Minimum Input 9 500 Btu n 2 78 kW ras Maximum Input 46 500 Btu h 13 62 kW VENTED GAS FIREPLACE LLI This appliance must be installed in accordance with the manufacturer s installation LL instructions and with local codes if any if none follow the current ANSI Z223 1 in lt the USA or the current CAN 1 B149 in Canada N This vented gas fireplace is not for use with air filters For Manufactured Home Installation This Direct Vent System Appliance must be O installed in accordance with the manufacturer s installation instructions and gt Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 or the Q current Standard for Fire Safety Criteria for Manufactured Home Installation Sites and O Communities ANSI NFPA 501A and with CAN CSA Z240 MH Mobile Home Standard in Canada This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes See owner s manual for details This appliance is not convertible for use with other gases unless a certified kit is used Kit 4546 969 Certified for use with Heat Wave Kit 4946 556 and Heat Relea
23. Firestop Spacer Trim Plate Black Regency L900E Direct Vent Gas Fireplace 58DVA 06 58DVA 06B 58DVA 09 58DVA 09B 58DVA 12 58DVA 12B 58DVA 18 58DVA 18B N A from FPI 58DVA 24 58DVA 24B 58DVA 36 58DVA 36B 58DVA 48 58DVA 48B 58DVA 60 58DVA 60B N A from FPI N A N A Disc See 58DV 08A Disc See 58DV 08AB Disc See 58DV 16A Disc See 58DV 16AB 58DVA 08A N A from FPI 58DVA 08AB 58DVA 16A N A from FPI 58DVA 16AB 58DVA E45 58DVA E45B Disc See 58DVA E45 Disc See 58DVA E45B 58DVA E90 58DVA E90B Disc See 58DVA E90 Disc See 58DVA E90B N A N A 58DVA DC 58DVA CS 58DVA WS 58DVA ES N A from FPI 58DVA WT 58DVA DC N A from FPI 58DVA FS 58DAV WFS Simpson Direct Vent GS Discontinued 1208 1208B 1207 1207B 1206 1206B 58DVA 18 58DVA 18B N A from FPI 1204 1204B 1203 1203B 1202 1202B 58DVA 60 58DVA 60B N A from FPI N A N A Disc See 58DV 08A Disc See 58DV 08AB Disc See 58DV 16A Disc See 58DV 16AB 58DVA 08A N A from FPI 58DVA 08AB 58DVA 16A N A from FPI 58DVA 16AB 1245 1245B 12456 1245BG 58DVA E90 58DVA E90B Disc See 58DVA E90 Disc See 58DVA E90B N A N A Selkirk Metal Fab Direct Temp Sure Seal 5D6 SDT 6 SDT 6B SDT 9 5SDT 9B SDT 12 5SDT 12B SDT 18 5SDT 18B 5DT 24 SDT 24B SDT 36 5 1 365 5DT 48 5SDT 48B N A N A Z gt E gt Z N A N A 5DT AJ 5DT AJB N A N A N A
24. N MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING BEDDING MATERIAL ETC IT IS IMPERATIVE THAT CONTROL COMPARTMENTS BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES ESPE CIALLY THE FIREPLACE GLASS AND SHOULD STAY AWAY TOAVOID BURNS OR CLOTHING IGNITION Regency L900E Direct Vent Gas Fireplace YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE CLOTHING OR OTHER FLAMMABLE MATERIALSHOULDNOTBEPLACED ON OR NEAR THE APPLIANCE GENERAL SAFETY INFORMATION 1 The appliance installation must conform with local codes or in the absence of local codes with the current Canadian or National Gas Codes CAN1 B149 or ANSI 2223 1 Installation Codes 2 The appliance when installed must be electrically grounded in accordance with local codes orin the absence of local codes with the current National Electrical Code ANSI NFPA 70 or CSA C22 1 Canadian Electrical Code 3 See general construction and assembly instructions The appliance and vent should be enclosed 4 This appliance must be connected to the spe
25. S LINE INSTALLATION Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN CGA B149 installation code For USA installations follow local codes and or the current National Fuel Gas Code ANSI 2223 1 When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be easily disconnected for servicing Flare nuts for copper lines and flex connectors are usually considered to meet this requirement Important Always check for gas leaks witha soap and water solution or gas leak detector Do not use open flame for leak testing PILOT ADJUSTMENT Periodically check the pilot flames Correct flame pattern has three strong blue flames 1 around the flame sensor and 1 flowing across the burner it does not have to be touching the burner Burner 00 060006 OO O O O O O ooo0oo0o0o0o0 Flame Sensor Pilot Ignitor Note Ifyou have an incorrect flame pattern contact your Regency dealer for further instructions Incorrect flame pattern will have small probably yellow flames not coming into proper contact with the rear burner or flame sensor GAS PIPE PRESSURE TESTING The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 45 kPa Disco
26. TION WITH FLEX VENT SYSTEM Note top clearance of 3 76mm and 1 Note 2 3 side amp bottom clearance of 2 51mm must be maintained except when passing through a wall ceiling or at the termination where the use of a firestop or wall thimble reduces the required clearance to 1 1 2 38mm Werecommendframing a 11 279mm x 11 279mm inside dimensions hole to give structural rigidity for mounting the termination Locate the unit in the framing rough in the gas preferably on the right side of the unit and the electrical Junction block is on the left side on the left Locate the centerline of the termination and mark wall accordingly Cut an 11 279mm hole in the wall inside dimension aft T at Fairing ng 2 If installing termination on a siding covered wall a vinyl siding standoff or vinyl furring strips must be used to ensure that the termination is not recessed into the siding Level the fireplace and fasten it to the fram ing using nails or screws through the nailing strips Assemble the vent assembly by applying Mill Pac to the 5 127mm inner collar of the termination and slipping the 5 127mm liner over it at least 1 3 8 35mm Fasten with the 3 screws drilling pilot holes will make this easier Apply Mill Pac or high temperature silicone to the 8 203mm flex pipe and slip it over the 8 outer collar of the vent terminal at least 1 3 8 35mm and fas
27. TRICTOR SETTING rd OOP Vent restrictor at 0 factory set no adjustment required 20 Regency L900E Direct Vent Gas Fireplace INSTALLATION Vertical Venting with Three 3 90 Elbows One 90 elbow Two 45 elbows With these options max total pipe length is 30 feet with min of 10 feet total vertical and max 8 feet total horizontal Z gt E gt Z Please note min 1 foot VENT RESTRICTOR SETTING between 90 elbows is Vent restrictor at 0 factory set no required adjustment required KJ J KJ S Regency L900E Direct Vent Gas Fireplace 21 INSTALLATION VENTING ARRANGEMENTS ALLOWABLE VERTICAL TERMINATIONS The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations using two 90 elbows with Rigid Pipe Venting Systems for Propane and Natural Gas Two 45 elbows equal to one 90 elbow Maximum of four 45 elbows allowed O x x ep Z f4 if Jz i FAG Vent Restrictor on Set 3 VL NNN aes VG 24 22 TT oO S 20 OD E N I OG Re AB er a Vent Restrictor on Set 2 N gt z E 16 5 gt 14 12 SM SO a SR SE SER Eee 10 Vent Restrictor on Set 1 NS 8 E 5
28. VAL LIMON SIONS vasre eee 6 INSTALLATION Important Message rrrrnnnernnnennnnernnnennnnnnnnnnnnnnnennnnene 7 Before YOU Sta eaan a 7 General Safety Information rrrranrrrnnnrrnnnrnnnnrnnanennnre 7 Installation Checklist rarrrrnnrerrnrrrranerrannnrnnrrrnnnennnnen 7 Manufactured Mobile Home Additional Requirements 8 Locating Your Gas Fireplace rrrnnnnnnrnnnnnrnnnnnnrrnnnnennnn 8 Heatwave Duct Kit 555 055 05550555555550555955595555 555 8 Heat Release Kit 555 555550555055505535555950559055555559 555 8 Hearth Requirements ccccsccceccceecceeeeeseeseeesseesaees 8 CET 9 Mantel Clearance 10 Mantel Leg Clearances rrrannnnnnnrnannrnnnnrnnanennnnennnnen 10 Framing amp Finishing onrrrrnnnnrvnnnrrvrnnrrvrnnnnnrnnnnnnnnsnen 11 Unit Assembly Prior To Installation 12 Top Standoff Assembly 12 Side Nailing Strips erronnrrrnnnrrrrrnnrrnrnnnrnnnnnrennnnne 12 Finishing Template cccccseecseeeeeeecsseseeeeaeeeseeens 12 Venting INtrodUuCtion cccccccsseceeeeceeeceeeseeeeaeeeseeens 13 Vent Restrictor Position rrrrarnrarrranrvnernrnnnranennnnnnnnnn 13 Exterior Vent Termination Requirements 14
29. a white film may develop on the glass front as part of the curing process The glass should be cleaned after the unit has cooled down or the film will bake on and become very difficult to remove Use a non abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT LIGHTING PROCEDURE 1 Plug the power cord into 8 power outlet 2 Press and release the ON OFF button once on the Remote Control 3 After approximately 3 seconds the spark ignition system will spark for 30 seconds to light the main burner 4 The unit will turn on NOTE If the unit does not turn on within 90 seconds of pressing the ON OFF button on the Remote Control this means that the system is in lockout mode The unit will need to be reset as follows a Remove the left side exterior brick panel b Hold the reset button for 3 to 5 seconds or until LED stops blinking c Repeat step 2 Note Forcompleteremotecontrolfunctionality refer to the Fire Wizard manual SHUTDOWN PROCEDURE 1 Press and release the ON OFF button once on the Remote Control 2 If service is to be preformed you must disconnect both sources of power to the unit main power and the battery Regency L900E Direct Vent Gas Fireplace 33 O m gt O Z Z e x TI A OPERATING INSTRUCTIONS NORMAL OPERATING SOUNDS OF GAS APPLIANCES Itis possible that you will hear some sounds from your gas appliance This
30. ad screws and then hang it on the top bracket located directly above the heat shield close to the top of the firebox 4 Remove the battery by lifting off the velcro and bring out from the side b Swing the door out from the top and release the hinges on the of the firebox left and right side of the door by lifting them up Door lt gt Z m Z gt Z O 3 Loosen the 2 screws that hold the right side heat shield in place Heat Shield 6 Replace with new battery and reconnect battery wires accordingly 7 Re install the battery to the right side of the firebox 8 Re install the right side heat shield Regency L900E Direct Vent Gas Fireplace 37 MAINTENANGE 4 Disconnect both sources of power the power cord located on the 7 Disconnect the spark cable and valve sensor wires from the control left hand side of the firebox and the wires connected to the back up board battery located on the right side of the firebox Backup Battery Power Receptacle 5 Remove the control box by carefully lifting off the velcro and sliding it 8 Remove the cable tie from control box to release the wires Do not out from the side of the firebox discard cable tie 9 Remove the Ground screw from the control box 6 Disconnect the wire harnesses from the control board labelled A C D amp F Do not disconnect the the jumper cables labelled B LLI O Z Z
31. but may need adjusting due to either the local gas supply or altitude Open the air shutter for a blue flame or close for a more yellow flame In order to adjust the aeration the logs grate and burners will need to be removed to be able to access the shutters Minimum Air Shutter Opening NG Front Burner 1 4 Rear Burner 4 2 LP Front Burner 1 4 Rear Burner 3 8 CAUTION Carbon will be produced if air shutter is tightly closed Note Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty 26 Regency L900E Direct Vent Gas Fireplace INSTALLATION BACK UP BATTERY INSTALLATION 1 Unsecure the battery from the outer firebox base flange by cuttingthe 6 Connect the red and black wires to the battery accordingly cable tie and remove from protective wrapping 2 Remove the plastic pin protectors from the battery 3 Loosen the screw that holds the right side heat shield in place Z gt gt 4 Z 7 Place the battery into position on the velcro at the base of the firebox as shown Heat Shield 4 Lift the heat shield up and pull out slightly to clear the head screws and then hang it on the top bracket located directly above the heat shield close to the top of the firebox 5 Pull out the battery wires from the right side of the firebox l l 8 Re install the heat shield Regency L900E Direct Vent Gas Fireplac
32. by Z gt E gt Z standoffs The metal ends of the standoff may NOT be recessed into combustible construction Clearance to Combustibles from Back 0 Omm A Side 0 Omm ED Floor 0 Omm C ED 42 Minimum Clearance from Top of Front Facing Mantel min 17 1 2 445mm Ceiling 49 1245mm from top of front facing Side Wall to Unit 16 406mm E Y Horizontal Vent Clearances to Combustibles 2 Top 3 76mm Side 2 51mm lt Bottom 2 51 mm gt Vertical Vent Clearances to Combustibles All Sides 2 51mm __ 3 Alcove Clearances 76mm Min Depth 36 914mm Min Width 84 2134mm Min Height 84 2134mm Alcove side wall must have a minimum of 16 406mm clearance on one side WARNING Fire hazard is an extreme risk if these clearances air space to combustible materials are not adhered to It is of greatest importance that this fireplace and vent system be installed only in accordance with these instructions Regency L900E Direct Vent Gas Fireplace 9 INSTALLATION MANTEL CLEARANGES Z Because of the extreme heat this fireplace emits the mantel clearances are critical Combustible mantel clearances from top of front facing O are shown in the diagram below lt q Note non combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible d board lt
33. cified vent and termination cap to the outside of the building envelope Never vent to another room or inside a building Make sure that the vent is fitted as per Venting instructions 5 Inspect the venting system annually for blockage and any signs of deterioration 6 Venting terminals shall not be recessed into a wall or siding 7 Any safety glass removed for servicing must be replaced prior to operating the appliance 8 To prevent injury do not allow anyone who is unfamiliar with the operation to use the fireplace 9 Weargloves and safety glasses for protection while doing required maintenance 10 Be aware of electrical wiring locations in walls and ceilings when cutting holes for termination 11 Under no circumstances should this appliance be modified Parts that have to be removed for servicing should be replaced prior to operating this appliance INSTALLATION 12 Installation and any repairs to this appliance should be done by an authorized service person A professional service person should be called to inspect this appliance annually Make it practice to have all of your gas appliances checked annually 13 Do not slam shut or strike the glass door 14 Under no circumstances should any solid fuels wood paper cardboard coal etc be used in this appliance 15 The appliance area must be kept clear and free of combustible materials gases and other flammable vapours and liquids Emission
34. customer the installer must ensure that the appliance is firing correctly and operation fully explained to customer 200 8 SN NN This includes 1 Clocking the appliance to ensure the correct firing rate rate noted on label 48 000 NG Btu h 46 500 LP Btu h after burning appliance for 15 minutes 2 Ifrequired adjusting the primary airto ensure that the flame does not carbon First allow the unit to burn for 15 20 min to stabilize CAUTION Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer MANUFACTURED MOBILE HOME ADDITIONAL REQUIREMENTS 1 Ensure that structural members are not cut or weakened during installation 2 Ensure proper grounding using the 8 ground lug provided See Wiring Diagram section LOCATING YOUR GAS FIREPLACE 1 When selecting a location for your fireplace ensure that the clearances are met 2 The appliance must be installed on a flat solid continuous surface e g wood metal concrete This may be the floor or raised up on a platform to enhance its visual impact The appliance must be installed on a metal or wood panel extending the full width and depth of the appliance 3 The L900E Direct Vent Gas Fireplace can be installed in a recessed position or framed out into the room as in A B C and D See Diagram 1 Flat on Wall B Flat on Wall
35. des that is pre programmed into its memory This set of ID codes helps to differenti ate one Remote Control Handset from another so that only the control box with a matching ID code will respond to the appropriate Remote Control Handset To ensure the remote control is matched to the receiver correctly please follow the steps below 1 Install the 2 x AAA alkaline batteries into the Remote Control 2 Unplug and re plug the power cord The power cord is located on the left hand side of the appliance and will be plugged into the receptacle 3 Press and hold the PROG and FAN buttons simultaneously for up to 20 seconds During this time the remote will display LC while it is transmitting codes to the receiver 4 Once it is successfully transmitted wait for 20 seconds and press the ON OFF button on the remote control once and the burners will come on Ifis does not work the first time repeat steps 2 and 3 5 The remote control is now programmed to the receiver and the appliance can now be operated with it The control box will only learn the Remote ID codes during the first 30 seconds after power is applied and will ignore this special command from the Remote after the first 30 seconds NOTE This must only be performed by a quali fied installer OPERATING INSTRUCTIONS 1 Read and understand these instructions before operating this appliance 2 Check to see that all wiring is correct and enclosed to prevent
36. e 27 INSTALLATION BRICK PANEL INSTALLATION IMPORTANT Must install 1 set of brick panels The operation of this unit without the brick panels is prohibited Dangerous operating conditions may occur if the panels are broken Handle with care DO NOT FORCE INTO POSITION Interior Brick Panel Installation 3 Remove the 2 brick panel clips on the inside left and right side of the firebox by removing the screw 1 Remove the glass door x 4 x op Z a Release the 2 door latches on the left and right side at the top of the firebox p Latch 4 Place the 2 small back brick panels at the base of the firebox on the left and right side of the rear log tray b Swing the door out from the top and release the hinges on the left Motes MOE non SOR AEE OE DANE ENE and right side of the door by lifting them up Left Side Back Brick Panel Right Side Back Brick Panel Hinge Door eel c Place the door on a soft surface to prevent scratching 2 Unwrap the brick panels from the protective wrapping Note The logs must not be in the unit i Right Side Back Brick Panel Left Side 28 Regency L900E Direct Vent Gas Fireplace INSTALLATION 5 Install the back brick panel by carefully placing it against the back 7 Slide the left side brick panel into position and secure in place with wall of the firebox the brick panel clip that was removed in step 3 Z g
37. emove the log set 7 Remove the interior brick panels Back Burner Regency L900E Direct Vent Gas Fireplace 39 88 O Z Z LLI lt MAINTENANCE 11 Remove the rear log stand by removing the 4 screws Rear Log Stand e z ii 12 Carefully remove the bottom brick panel Ee 21 Bottom Brick Panel 13 Disconnect the inlet gas line from the valve 14 Disconnect the 2 connectors from the 15 Disconnect the molex connector from the valve Molex Connector Modulating Coil 16 Remove the igniter wire and the thermocouple wire from the control box 17 Release the two grey wire clips on the bottom of the fireplace to release the wires attached to the valve assembly 18 Disconnect the black and red wires from the solenoid valve 19 Remove the 16 screws that hold the valve tray to the firebox and slightly pull out the valve tray Valve Tray Valve Tray Slightly Removed 20 Ensure that all wiring is free and clear of any obstructions Completely pull out the valve tray 21 Replace the valve tray and reverse steps to re install 22 Turn on the gas supply and check for gas leaks 23 Re connect both sources of power 24 Re install the left heat shield 25 Re install the grate 26 Re install the interior brick panels 27 Re install the log set 28 Re install the glass door 29 Check the inlet and out
38. ent clean See installation and operating instructions accompanying appliance LIGHTING INSTRUCTIONS STOP Read the safety information above on this label Plug the power cord into a power outlet Press and release the ON OFF button once on the Remote Control After approximately 3 seconds the spark ignition system will spark for 30 seconds to light the main burner If the main burner does not light within 90 seconds you must reset the unit See instruction manual for details TO TURN OFF GAS APPLIANCE Press the ON OFF button once on the Remote Control If service is to be performed you must disconnect both sources of power to the unit main power and the battery DO NOT REMOVE THIS INSTRUCTION PLATE 18628 Regency L900E Direct Vent Gas Fireplace 35 Lu O Z Z Z lt MAINTENANCE MAINTENANCE INSTRUCTIONS 1 Always turn off the unit before cleaning For relighting refer to lighting instructions Keep the burner and control compartment clean by brushing and vacuuming at least once a year When cleaning the logs use a soft clean paint brush as the logs are fragile and easily damaged 2 Clean appliance and door with a damp cloth never when unit is hot Never use an abrasive cleaner The glass should be cleaned with a gas fireplace glass cleaner The glass should be cleaned when it starts looking cloudy 3 The heater is finished in a heat resistant paint and should only be refin
39. ever allow the vent to run downward This could cause high temperatures and may present a possible fire hazard 18 Regency L900E Direct Vent Gas Fireplace INSTALLATION VENTING ARRANGEMENTS ALLOWABLE HORIZONTAL TERMINATIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations using one 90 two 45 elbows equal one 90 elbow Note Must use optional rigid pipe adapter Part 770 994 when using Rigid Pipe Venting Systems Horizontal Feet 0 2 4 6 8 10 12 14 16 18 20 fe dE OK 11111 11 11 l l l 6 ae Resiicion 4 4 on Set2 Ni a y i 14 BE HV ON A oe oe Vent Restrictor Ja ra 3 N 2 l S I Oo T g FK oe pp Vent Restrictor see E Factory Set 0 wwe OD gt 4 76 1930mm 2 Minimum Height A Vent Guard is required when the AstroCap Requirement 5 is installed above grade at 7 feet or lower 0 Vv IMPORTANT NOTE e The Simpson Dura Vent and Selkirk Direct Temp horizontal termination caps cannot be used in any applications e Only the AstroCap XL and Snorkels are certified for horizontal terminations VENT RESTRICTOR SETTING Vent restrictor at 0 factory set no adjustment required unless otherwise indicated Refer to the Vent Restrictor Position section for details on how to change the vent rest
40. ffset Chart ili This all fe ll adjustments the ceiling and mark Spacer is allows for small adjustments GS 8 203mm Nominal Diameter ID the spot where the Diagram 2 i ventwill penetrate the roof Determine if ceiling Offset Pipe Length L Height 6 Continue to assemble pipe lengths inches mm inches mm inches joists roof rafters or other framing will obstruct the venting system You may wish to relocate the appliance or to offset as shown in Diagram 2 to avoid cutting load bearing members Note If an offset is necessary in the attic to avoid obstructions it is important to support the vent pipe every 3 feet 0 9 meter to avoid excessive 3 AFirestop spacer must be installed in the floor stress on the elbows and possible or ceiling of every level separation Wall straps are available for this purpose Diagram 2 framin A Galvanized pipe is desirable above the roofline due to its higher corrosion resistance Continue to add pipe sections through the flashing until the height of the vent cap meets the minimum height requirements specified in Diagram 5 or local codes Note that for steep roof pitches the vertical height must be increased Offset 7 Height firestop spacer N gt l 24 Regency L900E Direct Vent Gas Fireplace UNIT INSTALLATION HORIZONTAL TERMINA
41. he over 16 12 to 18 12 Venting Arrangemnt hole should be of sufficient size to meet Vertical Termination the minimum requirements for clearance to SEE section for the combustibles of 1 1 2 38mm Slipthe flashing PE KF maximum vertical rise under the shingles shingles should overlap hi el 1 du dd of the venting system and 2 We half the flashing as per Diagram 4 ign Mnd the maximum horizontal roof lines in these cases increasing the vent offset limitations height may solve the problem Diagram 1 2 Setthe gas appliance 7 Ensure vent is vertical and secure the base inits desired location El of the flashing to the roof with roofing rails Drop 8 plumb bob slide storm collar over the pipe section and down fromthe ceiling to the position of the plumber s appliance flue exit tape andmarkthelocation connected where the vent will to wall strap penetrate the ceiling Drill a small hole at wall seal with a mastic 8 Install the vertical termination cap by twist locking it Note Any closets or storage spaces which the vent passes through must be his point Next drop Strap 7 Elbows enclosed a plumb bob from Diagram 4 The upper half of the flashing is the roof to the hole installed under the roofing material and not previously drilled in T Firestop nailed down until the chimney is installed O
42. he room The kit may be used on either the left or right side See Heat Release installation manual for complete details and clearances from side only HEARTH REQUIREMENTS Aminimum 33 1 8 838mm wide x 12 305mm deep x 2 51mm thick non combustible hearth is required if the finished floor is not flush with the base of the unit The maximum height between the finished floor and sub floor is 1 25mm Unit Sitting on Sub Floor Non combustible Material Finished Floor 1 ae Base of Unit Exterior Brick Panel Non combustible Material 2 51mm NOTE No hearth is required when the unit is flush with the finished floor as shown below The minimum floor clearance must be maintained from the top surface of the carpet etc to the unit base Unit Sitting on Finished Floor Non combustible Material Finished Floor Regency L900E Direct Vent Gas Fireplace INSTALLATION CLEARANCES The clearances listed below are Minimum distances unless otherwise stated A major cause of chimney related fires is failure to maintain required clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions Caution Requirements The top back and sides of the fireplace are defined
43. ing Standoff Optional AstroCap XL Termination Cap Part 4946 623 P Wall Thimble Mandatory in all Horizontal Terminations 14 5 8 Pipe Length F R Length 1 9 0 Elbow O I 24 Pipe Length lt gt Rigid Pipe Adapter 770 994 A n WARNING Do not combine venting components from different venting systems Use of the the AstroCap XL is acceptable with all systems This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct Vent GS and Selkirk Direct Temp systems Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower IMPORTANT NOTE e The Simpson Dura Vent and Selkirk Direct Temp horizontal termination caps cannot be used in any applications e Only the AstroCap XL and Snorkels are certified for horizontal terminations When using Rigid Vent other than Simpson Dura Vent 3 screws must be used to secure rigid pipe to adaptor The FPI AstroCap XL is certified for installations using FPI venting systems as well as Simpson Dura Vent Direct Vent GS and Selkirk Direct Temp AstroCap XL is a proprietary trademark of FPI Fireplace Products International Ltd Dura Vent and Direct Vent GS are registered and or proprietary trademarks of Simpson Dura Vent Co Inc 16
44. intained except when passing highly recommended to apply Mill Pac through a wall ceiling or at the sealant supplied to every inner pipe connec WY termination where the use ofafirestop tion Failure to do so may result in drafting Minimum Vent or wall thimble reduces the required or performance issues not covered under Roof Pitch Height clearance to 1 1 2 38mm We warranty Silicone red RTV is optional recommend framing a 11 279mm x 11 279mm inside dimensions hole flat to 7 12 2 ost nidi Female to give structural rigidity for mounting Lock ng over 7 12 to 8 12 2 061 the termination 02 2 2 2 ie Lugs over 8 12 to 9 12 2 aintain the mm se clearances air spaces SI Mil Pac J gt Silicone over 9 12 to 10 12 4 5 T 5 to combustibles when 2 22 Male over 10 12 to 11 12 3 25 q Locking 325 passing through ceilings walls roofs enclosures Lugs over 11 12 to 12 12 4 122 attic rafter or other nearby if 8 over 12 12 to 14 12 5 152 combustible surfaces over 14 12 to 16 12 Do not pack air spaces 5 Cut a hole in the roof centered on the small with insulation Check drilled hole placed in the roof in Step 2 T
45. ion and must be folded into shape and attached 1 Remove the standoffs from the fireplace top 2 Take each standoff and bend into the correct shape Bend up at the bend lines until the screw holes in the standoff and the pre punched screw holes on the fireplace top line up 3 Attach the standoff securely to the top with 2 screws per standoff on opposite corners i Top Standoff Top Standoff after bending flat shipping position 12 SIDE NAILING STRIPS The side nailing strips come attached to the unit There are 3 plates one on the top and bottom that can be folded out as required Side Nailing Strips shown folded out FINISHING TEMPLATE In order to maintain a clean face the L900E allows for a 1 8 in overlap of finishing material such as rock or tile on both the left and right hand sides of the unit top and bottom sides do not allow for an overlap this overlap must not be exceeded or the glass door will no longer open properly Non combustible wall board is installed up to the flanges on all sides of the unit When installing any additional facing material use the Finishing Template included with the unit to ensure that the finishing material does not exceed the allowable overlap The Finishing Template uses two magnets to attach itself to the flange on the left or right side of the unit see diagram below Install the facing materia
46. ion may result causing property damage personal injury or loss of life Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult 8 qualified installer service agency or gas supplier A BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from 8 neighbours phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department B Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water C This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air 10 18 4 0 0 06 CAUTION Hot while in operation Do not touch Severe Burns may result Due to high surface temperatures keep children clothing and furniture gasoline and other liquids having flammable vapors away Keep burner and control compartm
47. ished with heat resistant paint Regency uses StoveBright Paint Metallic Black 6309 4 Make a periodic check of burner for proper position and condition Visually check the flame of the burner periodically making sure the flames are steady not lifting or floating If there is a problem call a qualified service person 5 The appliance and venting system must be inspected before use and at least annually by a qualified field service person to ensure that the flow of combustion and ventilation air is not obstructed Note Never operate the appliance without the glass properly secured in place 6 Donotuse this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 7 In the event this appliance has been serviced check that the vent air system has been properly resealed amp reinstalled in accordance with the manufacturer s instructions 8 Verify operation after servicing GENERAL VENT MAINTENANCE Conduct an inspection of the venting system semiannually Recommended areas to inspect as follows 1 Check the Venting System for corrosion in areas that are exposed to the elements These will appear as rust spots or streaks and in extreme cases holes These components should be replaced immediately 2 Remove the Cap and shine a flashlight down the Vent
48. l clearance to ventilated soffit located above the terminal within K Clearance to non mechanical air supply inlet to building or the a horizontal distance of 24 60cm from the centerline of the terminal combustion air inlet to any other appliance 12 30cm 9 23cm min 33 84cm check with local code L Clearance to a mechanical air supply inlet min 72 1 8m 3 91cm E Clearance to unventilated soffit min 33 84cm above if within 10 3m horizontally F Clearance to outside corner with AstroCap Termination Cap min M Clearance above paved sidewalk or a paved driveway located on 13 public property min 84 2 1m N Clearance under veranda porch deck or balcony min 33 84cm Note Excluding direct vent or non condensing appliances a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings Only permitted if veranda porch deck or balcony is fully open on a minimum of two sides beneath the floor If the vent termination is accessible a certified guard shall be installed As specified in CGA B149 Installation Code Note Local codes or regulations may require different clearances In accordance with the current ANSI Z223 1 NFPA 54 Natioinal Fuel Gas Code 14 Regency L900E Direct Vent Gas Fireplace INSTALLATION VENTING ARRANGEMENTS HORIZONTAL TERMINATION FLEX Regency Direct Vent System The
49. l the warmth and charm of wood fireplace at the flick of a switch The model L900E has been approved by Warnock Hersey for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace MANUFACTURED MOBILE HOME REQUIREMENTS INFORMATION FOR MOBILE MANUFACTURED HOMES AFTER FIRST SALE This Regency product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards VENTED GAS FIREPLACE HEATERS ANSI Z21 88 2005 CSA 2 33 2005 GAS FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN CGA 2 17 M91 and ANSI Z21 50b 2003 CSA 2 22b 2003 This Direct Vent System Appliance must be installed in accordance with the manufacturer s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 or the current Standard of Fire Safety Criteria for Manufactured Home Installations Sites and Communities ANSI NFPA 501A and with CAN CSA Z240 MH Mobile Home Standard in Canada This appliance installation must comply with the manufacturer s installation instructions and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z223 1 and the current National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B
50. l up to the outside edge when facing the unit of the finishing template This template may be discarded after the facing material has been installed Regency L900E Direct Vent Gas Fireplace INSTALLATION need to use heated room air for combustion and losing warm room air up the chimney VENTING To set the vent restriction as indicated in the Screws for plugging the holes venting arrangements diagrams refer to the all holes must be plugged with a screw INTRODUCTION instructions below e Screw holes for fixing the restrictor plate The L900E uses the balanced flue technology 1 Remove the glass door a Co Axial system The inner liner vents products a Release the 2 door latches on the left of combustion to the outside while the outer and right side at the top of the firebox gt liner draws outside combustion air into the EG combustion chamber thereby eliminating the O Z Note These flue pipes must not be connected to any other appliance The gas appliance and vent system must be vented directly to the outside of the building Factory Set Vent Restrictor Setting and never be attached to a chimney serving a no adjustment required separate solid fuel or gas burning appliance Each direct vent gas appliance must use it s own separate vent system Common vent systems are prohibited Latch VENT RESTRICTOR POSITION Vent restriction is required for certain venting installations see
51. let pressures 30 Re install the right heat shield 31 Check operation of flame control 32 Check for proper flame appearance 33 Re install the exterior brick panels 40 Regency L900E Direct Vent Gas Fireplace PARTS LIST MAIN ASSEMBLY Part Description 1 521 527 Flue Collar Inner Assembly 1 at 2 502 008 Flue Collar Outer 5 904 751 Capscrew 1 4 x 4 1 2 6 W260280 Gasket Top Relief Plate 7 770 066 Top Relief Plate 8 942 117 Top Relief Frame 9 W260260 Top Relief Frame Gasket 11 910 950 IPI Control Box and Battery Backup 910 075 Backup Battery Not shown 12 546 540 Door Frame Assembly with Glass 940 354 P Glass 13 546 013 One Piece Faceplate 15 521 021F Control Arm 16 521 019 Bracket Control Arm 17 546 070 Heat Shield Valve 18 521 072 Gas Line Screen Plate 20 546 901 Brick Panel Set Standard Brown 546 902 Brick Panel Set Standard Red Left Side Panel Interior Top Panel Interior Back Panel Interior Right Side Panel Interior Right Side Panel Exterior Base Panel Exterior Left Side Panel Exterior 946 556 Heat Wave Kit 946 570 Heat Release Kit 546 969E LP Converison Kit 918 623 Manual Not available as a replacement part 13 y gt 3 3 Op E Regency L900E Direct Vent Gas Fireplace 41 3 op H PARTS LIST 30 31 32 35 36 37 41 42 43
52. nnect piping from valve at pressures over 1 2 psig The manifold pressure is controlled by aregulator builtinto the gas control and should be checked at the pressure test point Note Toproperly check gas pressure both inlet and manifold pressures should be checked using the valve pressure ports on the valve 1 Make sure the unit is turned OFF 2 Loosen the IN and or OUT pressure tap s turning counterclockwise with a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pressure tap s using a 5 16 ID hose 4 Turn the unit ON 5 The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label 6 When finished reading manometer turn off the unit disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screw should be snug but do not over tighten SIT 845 VALVE DESCRIPTION 1 On Off Solenoid Valve EV1 2 On Off Solenoid Valve EV2 3 Inlet Pressure Test Point 4 Outlet Pressure Test Point 5 Connection for Pressure Regulator Combustion Chamber Compensation 6 Pressure Regulator for Minimum and Maximum Outlet Pressure 7 Gas Outlet Pressure Electric Modulator 8 Pilot Outlet 9 Main Gas Outlet 10 Side Outlet 11 Main Gas Inlet AERATION ADJUSTMENT The burner aeration is factory set
53. o run downward This using nails or screws through the top and could cause high temperatures and may side nailing strips present the possibility of a fire 5 Assemble the desired combination of pipe and elbows to the appliance adaptor and twist lock for 8 solid connection Note For best results and optimum performance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may result in drafting or performance issues not covered under warranty Silicone red RTV is optional Diagram 1 Regency L900E Direct Vent Gas Fireplace b The location of the horizontal vent termination on an exterior wall must meet all local and national building codes and must not be blocked or obstructed See Exterior Vent Termination Locations section for more details 7 Ensure that the pipe clearances to combustible materials are maintained Diagram 5 Install the termination cap Note If installing termination on a vinyl siding covered wall a vinyl siding standoff or furring strips must be used to ensure that the termination is not recessed into the siding Siding 3 20 sealant all four sides bolt Horizontal lt Top to Vinyl Standoff lt 8 9 lt 4
54. on the next adjacent floor level b In the event that the requirements of this subdivision can not be met at the time of completion of installation the owner shall have a period of thirty 30 days to comply with the above requirements provided however that during said thirty 30 day period a battery operated carbon monoxide detector with an alarm shall be installed 2 APPROVED CARBON MONOXIDE DETECTORS Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight 8 feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5 08 2 8 1 through 4 b EXEMPTIONS The following equipment is exempt from 248 CMR 5 08 2 8 1 through 4 1 The equipment listed in Chapter 10 entitled Equipment Not Required To Be Vented in the mo
55. ot clean when the glass is hot The use of substitute glass will void all product warranties Care must be taken to avoid breakage of the glass Do not strike or abuse the glass Do not operate this fireplace without the glass front or with a cracked or broken glass front Wear gloves when removing damaged or broken glass Replacement of the glass panel s should be done by a licensed or qualified service per son GLASS REPLACEMENT In the event that you break your glass by impact purchase your replacement from an authorized Regency dealer only Replacement glass is shipped already installed into the door frame CAUTION Wear gloves when removing damaged or broken glass WARNING Do not operate the appliance with the glass panels removed cracked or broken Replacement ofthe glass panels should be done by a licensed or qualified service person 36 Regency L900E Direct Vent Gas Fireplace MAINTAINENCE BACK UP BATTERY REPLACEMENT CONTROL BOX REPLACEMENT 1 Disconnect the power cord located on the left hand side of the firebox 1 Remove the exterior brick panels Power Receptacle 2 Remove the glass door a Release the 2 door latches on the left and right side at the top of the firebox a 48 Latch Location Latch Heat Shield 2 Loosen the 2 screws that hold the right side heat shield in place 3 Lift the heat shield up and pull out slightly to clear the he
56. possible shock 3 Check to ensure there are no gas leaks 4 Make sure the glass in the door frame is properly positioned Never operate the appliance with the glass removed 5 Verify that the venting and cap are unobstructed 6 Ensure that the brick panels are installed 7 Verify log placement If the pilot cannot be seen when lighting the unit the logs have been incorrectly positioned 8 The unit should never be turned off and on again without a minimum of a 60 second wait FIRST FIRE The FIRST FIRE in your heater is part of the paint curing process To ensure the paint is properly cured it is recommended you burn your fireplace for at least four 4 hours the first time When first operated the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufac turing Smoke detectors in the house may go off at this time Open a few windows to ventilate the room for a couple of hours The glass may require cleaning NOTE The main burner will always start on HIGH and resume it s last setting after 20 seconds of operation NOTE When the glass is cold and the appliance is lit it may Cause condensation and fog the glass This condensation is normal and will disappear in a few minutes as the glass heats up DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT During the first few fires
57. r out INSTALLATION IMPORTANT Do not locate termination hood where excessive snow or ice buildup may occur Be sure to check vent termination area after snow falls and clear to prevent accidental blockage of venting system When using snow blowers make sure snow 5 not directed towards vent termination area Z gt E gt Z ASTROCAP XL DIMENSIONS 946 623 P Q 12 1 4 311mm 12 1 4 311mm 2 x 4 or 2 x 6 5 dia fl 7 with ine sa me pl X n y 8 dia air intake Screws Vinyl Siding sorsas Wall Thimble Mandatory on all horizontal terminations 25 INSTALLATION INSTALLATION L900E NG SYSTEM DATA 5 WC 1 25 kpa 1 6 WC 0 39 kpa Min Supply Pressure Low Setting Man Pressure Max Manifold Pressure 3 5 WC 0 87 kpa Orifice Size Front 47 DMS Burner Orifice Size Back Burner 30 DMS 11 000 Btu h 3 22 kW 48 000 Btu h 12 3 kW L900E LP SYSTEM DATA 12 WC 2 98 kpa 3 6 WC 2 49 kpa Minimum Input Maximum Input Min Supply Pressure Low Setting Man Pressure Max Manifold Pressure 10 WC 2 98 kpa 56 DMS Orifice Size Front Burner Orifice Size Back Burner 50 DMS 9 500 Btu h 2 64 kW 46 500 Btu h 11 72 kW Minimum Input Maxiumm Input HIGH ELEVATION This unit is approved in Canada for altitude 0 to 4500 ft CAN1 2 17 M91 GA
58. rictor to Set 1 Set 2 or Set 3 if required A vent guard is required when the AstroCap is installed above grade at 7 feet or lower vent guard may also be required in other installations as per local codes refer to Exterior Vent Termination Requirements section for details Note Regency Direct Vent System Flex is only approved for horizontal terminations e Maintain clearances to combustibles as listed in Clearances section e Horizontal vent must be supported every 3 feet e Firestops are required at each floor level and whenever passing through a wall e A wall thimble is mandatory for all horizontal terminations due to high temperatures Regency L900E Direct Vent Gas Fireplace 19 Z gt i gt Z INSTALLATION Horizontal Venting with Two 2 90 Elbows O x x ep Z One 90 elbow Two 45 elbows With these options maximum total pipe length is 30 feet with minimum of 10 feet total vertical and maximum 10 feet total horizontal Please note minimum 1 foot between 90 elbows is required VENT RESTRICTOR SETTING Vent restrictor at 0 factory set no adjustment required Horizontal Venting with Three 3 90 Elbows One 90 elbow Two 45 elbows With these options max total pipe length is 30 feet with min of 11 feet total vertical and max 10 feet total horizontal Please note min 1 VENT RES
59. s from burning wood or gas could contain chemicals known to the State of California to cause cancer birth defects or other reproductive harm INSTALLATION CHECKLIST 1 Locate appliance a Room location Refer to Locating Your Gas fireplace section b Clearances to Combustibles Refer to Clearances section c Mantle Clearances Refer to Mantel Clearances section d Framing amp Finishing Requirements Refer to Framing amp Finishing section e Venting Requirements Refer to Venting section 2 Assemble Top Standoffs Refer to Unit Assembly Prior to Installation 3 Install back up batteries Refer to Back up Battery Installation section 4 Slide unit into place 5 Install vent Refer to Venting Arrangement sections 6 Make gas connections Refer to Gas Line Installation section 7 Makeelectrical connections Refer to Wiring Diagram section NOTE Unit requires 120V to operate 8 Test the pilot Refer to Pilot Adjustment section 9 Test Gas Pressure Refer to Gas Pipe Pressure Testing section 10 Install standard and optional features Refer to the following sections Z gt gt O x x ep Z INSTALLATION Interior Brick Panels Log Set Exterior Brick Panels Remote Control refer to Matching Remote Handset amp Control Box ID Code section 11 Final check Before leaving this unit with the
60. se Kit 4946 570 For use with glass doors certified with the appliance only Electrical Supply 120 V 0 22 A 60 Hz NOT FOR USE WITH SOLID FUEL For the State of Massachusetts installation See aan Eee E from Fireplace and repair must be done by plumber or on 06mm gasfitter licensed in the Commonwealth of Ceiling B 49 1245mm Massachusetts Min Mantel Height C 17 1 2 445mm l Max Mantel Depth D 13 330mm For the State of Massachusetts flexible Alcove Width E 84 2134mm connectors shall not exceed 36 inches in Alcove Depth F 36 914mm length Non Combustible Hearth Extension For the State of Massachusetts the appli Hearth Height G 2 51mm ances individual manual shut off must be 8 Hearth Width H 33 1 8 841mm t handle type valve l Alcove side wall must have a min of 16 406mm clearance on one side The State of Massachusetts SJUNGS the Mantel depth taken at 27 1 2 699mm from front facing installation of a carbon monoxide alarm in accordance with NFPA 720 and 8 CO alarm FPI Fireplace Products International Ltd Delta BC CANADA with battery back up in the same room where MADE IN CANADA FABRIQUE AU CANADA 918 624 the gas appliance is installed 4 Regency L900E Direct Vent Gas Fireplace REQUIREMENTS MA Code CO Detector for the State of Massachusetts only 5 08 Modifications to NFPA 54 Chapter 10 2 Revise 10 8 3 by adding the following additional req
61. se venting systems in combination with the L900E have been tested and listed as direct vent system by Warnock Hersey The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram from the Exterior Vent Termination Locations section Z gt E gt Z FPI Direct Vent Flex System Termination Kits include all the parts needed to install the L900E using a flexible vent 1 946 618 6 Feet 8 flexible liner Kit length 5 flexible liner Kit length spring spacers 3 thimble 2 AstroCap termination cap 1 946 616 10 Feet screws 12 tube of Mill Pac 1 plated screws 8 S S screws 8 x 1 1 2 drill point 4 vinyl siding standoff Vinyl Siding standoff Wall Thimble PS Mandatory in all Horizontal Terminations uard if required art 946 506 P AstroCap XL Termination Cap Part 946 623 P 8 dia Flue pipe gt A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower Notes 1 Liner sections should be continuous without any joints or seams 2 Only Flex pipe purchased from FPI may be used for Flex installations 3 Horizontal vent must be supported every 3 feet 4 Awallthimble is mandatory for all horizontal terminations due to high temperatures Regency L900E Direct Vent Gas Fireplace 15 O x x ep Z INSTALLATION
62. sidized labour and parts only thereafter Glass is covered for lifetime against thermal breakage only parts and subsidized labour for five 5 years and parts only thereafter from date of purchase Electrical and mechanical components such as switches wiring FPI remote controls pilot assembly components control boards and gas valves are covered for two years parts and one year subsidized labour from the date of purchase Blowers and valves replaced under warranty are considered repairs and continue as if new with appliance ie twelve 12 months from original purchase date of appliance with a minimum of three 3 months coverage from date of replacement FPI venting components are covered parts and subsidized labour for three 3 years from date of purchase Simpson Dura Vent venting components Direct Vent units are covered by Simpson Dura Vent Inc warranty Repair replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty valid with a receipt only Any item shown to be defective will be repaired or replaced at our discretion No labor coverage is included with these parts Conditions Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI s option through an accredited distributor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid if requested I
63. st current edition of NFPA 54 as adopted by the Board and 2 Product Approved side wall horizontally vented gas fueled equipment installed in 8 room or structure separate from the dwelling building or structure used in whole or in part for residential purposes c MANUFACTURER REQUIREMENTS GAS EQUIPMENT VENTING SYSTEM PROVIDED When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment the instructions provided by the manufacturer for installation of the equipment and the venting system shall include 1 Detailed instructions for the installation of the venting system design or the venting system components and 2 A complete parts list for the venting system design or venting system d MANUFACTURER REQUIREMENTS GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases but identifies special venting systems the following requirements shall be satisfied by the manufacturer 1 The referenced special venting system instructions shall be included with the appliance or equipment installation instructions and 2 The special venting systems shall be Product Approved by the Board and the instructions for that system shall include a parts list and detailed installation instructions 6 A copy of
64. t E gt 4 Exterior Brick Panel Installation 1 Ensure installation of the logs and glass door has been completed before installing the exterior brick panels 2 Line up the pins in the exterior base brick panel with the holes on the outerbox of the firebox and fit in place 6 Place the top brick panel into position and hold it in place while slid ing the right side brick panel into position and secure using the brick panel clip that was removed in step 3 Outerbox of Firebox 3 Install the right side exterior brick panel by placing the bottom tab into the slot of the exterior base brick panel The top of the brick panel is held in place by a magnet that sits against the bracket as shown in the image below Repeat for left side exterior brick panel Tab Base Brick Panel Slot Regency L900E Direct Vent Gas Fireplace 29 x 4 x op Z INSTALLATION LOG SET INSTALLATION Installation of Interior Brick Panels must be completed before installing the log set Read the instructions below carefully and refer to the diagrams 3 Place log 03 42 on the front left side of the burner Place the right If the logs are broken do not use the unit until they are replaced end of the log into the pin and rest the notch on the left end of the Broken logs can interfere with pilot operation log on the grate Log kit Part No 546 930 and 546 935 contain the following pieces
65. t Vent Vent Guard Optional 946 623 P AstroCap XL Horizontal Cap 770 994 Rigid Pipe Adapter Must use with all Rigid Piping 946 506 P Vent Guard Optional NOTE When using Metal Fab Sure Seal Rigid Piping please note that either the Adaptor 5DDA or 90 Starter Elbow SD90A must be used in conjunction with FPI Rigid Pipe Adaptor 770 994 L676 amp L900 Direct Vent Fireplace IMPORTANT NOTE e A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower e The Simpson Dura Vent and Selkirk Direct Temp horizontal termination caps cannot be used in any applications e Only the AstroCap XL and Snorkels are certified for horizontal terminations Offset Pipe Selection Use this table to determine offset pipe lengths For specific instructions or details on particular 5 x 8 Venting venting components please visit the following websites Pipe Length Run X Rise Y 0 Omm 5 11 16 144mm 15 5 16 389mm Selkirk Direct Temp www selkirkcorp com 6 152mm 8 13 1 6 224mm 18 7 16 468 Metal Fab Sure Seal www mtlfab com 9 229mm 10 15 16 278mm MR 12 305mm 13 330 22 11 16 576mm lt a 24 610mm 21 7 16 697mm X 36 914mm 29 13 16 757 29 7 16 1002 48 1219mm 38 1 4 972mm 47 7 8 1216mm 4 X gt NOTE Horizontal runs of vent must be level or have a 1 4 inch rise for every 1 foot of run towards the termination N
66. t is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect The authorized selling dealer is responsible for all in field service work carried out on your Regency product FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that all submitted claims provide all of the necessary information including customer name purchase date serial type of unit problem and part or parts requested without this information the warranty will be invalid Exclusions This limited Lifetime Warranty does not extend to or include paint door or glass gasketing or trim At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit FPI has no obligation to enhance or modify any unit once manufactured ie as products evolve field modifications or upgrades will not be performed FPI will not be liable for travel costs for service work Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy Embers gaskets and paint are not covered under the terms of this
67. t the unit as follows a Remove the left side exterior brick panel b Hold the reset button for 3 to 5 seconds or until the LED stops blinking c Press and release the ON OFF button once on the Remote Control Reset Button Located on the left hand side of the firebox behind the exterior brick panel BACKUP BATTERY Listed below are approved battery types that can be used for replacement a Powersonic 1 3AH b Panasonic 1 3AH c Henda 1 3AH d Magnacharge 1 3AH CAUTION Risk of Energy Hazard 12V 1 3 Amphere hour battery Before replacing batteries remove con ductive jewelry such as chains wrist watches and rings High energy through conductive materials could cause severe burns Dispose of batteries at an authorized battery disposal site Do not dispose of batteries in a fire The batteries may explode Do not open or mutilate batteries Released material is harmful to the skin and eyes It may be toxic NOTE This must only be performed by a quali fied installer 34 Regency L900E Direct Vent Gas Fireplace OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 or Natural Gas and Propane Installation Codes CSA B149 1 WARNING If you do not follow these instructions exactly a fire or explos
68. ten with the 3 screws NOTE Horizontal sections must be sup ported at intervals not exceeding 3 feet 0 9 meter Flame picture and performance will be affected by sags in the liner Regency L900E Direct Vent Gas Fireplace 4 5 6 7 8 9 Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom Fasten the other thimble half to the inside wall The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls Slip the assembled liner and termination assembly through the thimble making sure the termination cap faces up there are markings on the cap that show which way is up This will position the termination cap with proper down slope for draining water Fasten the cap to the outer wall with the 4 supplied screws Pull the centre 5 127mm liner and outer 8 203mm liner out enough to slip over the flue collars of the fireplace You may wish to cut the liner shorter to make it more workable Do not bend liner more than 90 The liners must slip over the collars a minimum of 1 3 8 Apply Mill Pac over the fireplace inner collar and slip the 5 127mm liner down over it and attach with 3 supplied screws Do the same with the 8 203mm liner Apply a bead of silicone between the thimble and termination and around the outer edge of the terminal at the wall in order to keep the wate
69. the diagrams in the Venting Arrangements section to determine if they are required for your installation Swing the door outfrom the top and release the hinges on the left and right side of the door by lifting them up The Vent Restrictor plate is located on the inside top of the firebox Vent Restrictor Plate Door Vent Restrictor Set 2 2 Remove the screws that hold the vent restric tor plate in place 3 Adjustthe ventrestrictor plate to the required vent restrictor position as per the diagrams shown 4 Oncethe ventrestrictor plate is in the required A N position secure with screws i a hi Vent Restrictor Set 3 Regency L900E Direct Vent Gas Fireplace 13 O x x ep Z INSTALLATION EXTERIOR VENT TERMINATION REQUIREMENTS Openable Vent Termination Q Air Supply Outlet Area where terminal is not permitted A Clearance above grade veranda porch deck or balcony min G Clearance to inside corner with AstroCap Termination Cap min 12 30cm 18 B Clearance to window or door that may be opened 12 30cm H Notto be installed above a meter regulator assembly within 3 90cm 9 23cm horizontally from the centerline of the regulator C Clearance to permanently closed window min 12 30cm J Clearance to service regulator vent outlet min 36 90cm D Vertica
70. tructed of non combustible material i e masonry block or concrete an 8 203mm diameter hole is acceptable center of hole Install the vent system according to the manufacturer s instructions included with the components Set the unit in its desired location Check to determine if wall studs or roof rafters are in the way when the venting system is attached If this is the case you may want to adjust the location of the unit Rough in the gas preferably on the right side of the unit and L the electrical junction block is on the left side on the left 2 DirectVentpipe andfittings are designed with special twist lock connections to connect the venting system to the appliance flue outlet A twist lock appliance adaptor is required 76 1930mm Min height 3 In conjunction with the Simpson Dura Vent Direct Vent GS system Install the adaptor after the unit is set in its desired location Put a bead of high temperature silicone inside the outer section of the adapter and a bead of Mill Pack on the inner collar Slip the adapter over the existing inner and outer flue collar Fasten to the outer collar only with the 3 supplied screws drilling pilot holes will make this easier Diagram 2 Note a The horizontal run of vent must be level or have 1 4 inch rise for every 1 foot of run towards the termination Never 4 Levelthe fireplace and fasten it to the framing allow the vent t
71. uirements a For all side wall horizontally vented gas fueled equipment installed in every dwelling building or structure used in whole or in part for residential purposes including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven 7 feet above finished grade in the area of the venting including but not limited to decks and porches the following requirements shall be satisfied Z gt gt Z 1 INSTALLATION OF CARBON MONOXIDE DETECTORS At the time of installation of the side wall horizontal vented gas fueled equipment the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back up is installed on the floor level where the gas equipment is to be installed In addition the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling building or structure served by the side wall horizontal vented gas fueled equipment It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors a In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic the hard wired carbon monoxide detector with alarm and battery back up may be installed
72. y before it leaves our door FPI Fireplace Products International Ltd is pleasedto extend this Limited Lifetime Warranty to the original purchaser of a FPI Product See the inside back cover for details Register your Regency online at http www regency fire com a a G l E Ti a T ST 1 5 25 md 1 Installer Please complete the following information Dealer Name amp Address Installer Phone Date Installed Serial No
Download Pdf Manuals
Related Search
Related Contents
PN-G655 取扱説明書 Groupe SEB USA - T-FAL Turbo Pro User's Manual Application interface specification for IBM 4610 PDF manual Delta Electronics OPGP-34-A4B3RA User's Manual capitolato speciale di appalto - Università degli Studi di Teramo FLEXI WASCHTISCH - Pro-Ipso MXL Microphone USB-77 User's Manual HiFi-Receiver AMP-2580 Copyright © All rights reserved.