Contents
1. UPS Status Green LED Red LED Buzzer Self test Blink 1 by turns B1 AC Charging ON X X aa Charge Off ON x x Low Battery Self test ON Blink 2 B2 Over Load ON Blink 2 B4 DC Normal Blink 2 x B1 Battery Over Load Blink 2 Blink 2 B4 Low Battery Blink 2 Blink 2 B3 Short Fault X ON ON Over Battery Battery Fault X Blink 2 B5 Notes Blink 1 ON 0 5 seconds OFF 0 5 seconds Blink 2 ON 0 25 seconds OFF 0 25 seconds B1 1 beep 5seconds ON 0 25 seconds OFF 4 75 seconds B2 3 beeps 30 seconds ON 0 25 seconds OFF 0 25 seconds 3 times 28 5 seconds OFF B3 2 beeps 5seconds ON 0 25 seconds OFF 0 25 seconds 2 times 4 seconds OFF B4 ON 0 5 seconds OFF 0 5 seconds B5 3 beeps 5seconds ON 0 25 seconds OFF 0 25 seconds 3 times 3 5 seconds OFF SPECIFICATIONS Model Numbers PW3105 350A PW3105 500A PW3105 700A Capacity 350 VA 210W 500 VA 300W 700 VA 420W Nominal Input Voltage 240Vac Nominal Output Voltage 240Vac Frequency 50 60 Hz auto sensing Total6 Outlets 3 Battery Backup amp Surge Protection 3 Surge Protection only Lighting Surge Protection 476 Joules Transfer Time to Battery AC 6ms Typical Battery Type Maintenance free Sealed and leak prooflead acid battery Battery Specification 350 500VA 12V 5AH 750 VA 12V 7AH Typical Backup Time 3 minutes minimumat full ratedload
2. Internet Phone Fax Protection RJ11 Short Circuit Protection Circuit Breaker Communication Port USB Operating Temperature 0 C to 40 C Operating Relative Humidity 0 to 95 non condensing Storage Temperature 15 C to 50C Meriah B00VA 5 5 Kg 700VA 7 kg Dimensions W xD x H 280 x180 x115mm Due tocontinuing product improvementprograms specifications subjectto change without notice UPS is makinga continuous sound and the Overload indicator is lighted The Battery Backup amp Surge Protection outlets are overloaded Turn offthe UPS andreduce the amount of equipmentconnected to these outlets UPS does notprovide expected runtime The battery isnot fully charged Removed all connected equipments from the UPS and charge the battery at least 8 hours During this charging period turn off the UPS to prevent unnecessary discharging Battery is getting older Call for service or you can replace the battery by ordering one from your dealer When utility power fails connected equipment loses power The UPS is overloaded Reduce the amount of equipment plugged into the outlets of the UPS Try reducing the load by removing one piece of equipment at a time to determine if the problem continues The UPS has exhausted its available runtime The UPS willturn offwhen the battery has beendepleted during an extended poweroutage Allow the UPS tore charge
3. Powerware 3105 UPS USER S MANUAL The Powerware 3105 uninterruptible power system UPS protects your sensitive electronic equipment from basic power problems such as power failures power sags power surges andline noise Features e Six outlets Three with surge and battery backup protection Three with surge protection only Telephoneline surge protectionjacks Cold Start capability Proprietary LanSafe Powermanagement software User replaceable batteries Built in USB communication port Compact design fits on under your desk can also be mounted to a wall Convenient transformer block spacing SAFETY INSTRUCTIONS Once you have received the Powerware 3105 UPS product you should remove and inspect the product for shipping damage If any damage is found please notify the carrier and your dealer Please keep the shipping carton and the packing foam in the event the product must be returned to the factory for service ATTENTION Maintenance must be performed by a qualified personnel Failure to do so could result in an electric shock Replace Battery with Powerware supplied Battery ONLY Although the unit may be unplugged from utility power hazardous voltage still may be present through the battery 1 Place the Powerware 3105 UPS indoors in an area that has adequate airflow and is freeof excessive dust Do NOT allow the UPSto be exposedto moisture rain excessive heat or directsunlight 2 Use ofthe Powerware 3105UPS pro
4. Ps 1 On Off Push Button Switch One switch controls the power to your equipment Upon power turn on unit performs a self test NOTE Turnon the UPS Press the push button switch locked in toturn on the UPS NOTE Turn off the UPS Press the push button switch again to turn off the UPS NOTE Self Test The UPS performs a self test for about 5 seconds when the UPS is turned on 2 On Off Battery LED Indicates the UPS is on and is powering your equipment Aconstantly illuminated LED indicates normal utility power operation A blinking LED indicates that the UPS is providing power from its battery 3 Fault Warning LED Indicates a fault or warning conditionis present Aconstantly illuminated LED indicates a fault or output SHORT condition A blinking LED indicates the UPS is overloaded or BAD battery condition 4 Battery Backup amp Surge Protection Outlets Four Australian output receptacles that provide both battery backup and surge protection 5 Surge Protection Outlets Four Australian output receptacles that provide surge and spike protection 6 Phone Fax Protection Connectors RJ11 7 USB Communication Port The provided LanSafe monitoring and shutdown software can be automatically configured to save your files and shut down your computer in the event ofa prolonged power outage Your personal computer can receive the status of utility powerline utility power failure on battery and low battery by contact closure signals t
5. Installation and Operation Following steps explain how to connect and operate the Powerware 3105 UPS 1 Connect the UPS toa grounded power outlet Note Itis recommended that the battery should be charged for minimum 8 hours to ensure full charge before placing the UPS inservice 2 Plug your computer monitor or load to be protected into the Battery Backup amp Surge Protection outlets These outlets will provide emergency battery backup power during power outages as well as protection from surges and spikes CAUTION Do NOT plug LASER PRINTERS into the Battery Backup outlets CAUTION Do NOT plug ACCESSORY SURGE strips into the Battery Backup outlets 3 Plug yourperipheral equipment ornon critical loads printer scanner fax speaker etc into the Surge Protection outlets These outlets provide surge and spike protection only they will NOT provide battery backup power during a utility power failure Connect your computer to the UPS using USB cable provided With your equipment turnedoff switchon the UPS When the On Off LED light is illuminated turn on the connected equipment Install Power management software provided with the UPS NOOSA INDICATORS i i i i eo KAJ D Ome a 4 I F y
6. duct inlife support applications where failure of thisequipment can reasonably be expected tocause failure oflife support equipment orto significantly affect its safety or effectiveness is NOT recommended 3 Disconnect the input power cord from the wall outlet before replacing the battery 4 When replacing the battery use the same numberand type ofbattery 5 Do NOT dispose of battery ina fire The battery may explode 6 Do NOT open or mutilate the battery They contain an electrolyte that is toxic and harmful to the skin and eyes 7 Proper disposal of the battery is required Please refer to your local laws regulations regarding battery disposal 8 Use tools with insulated handles to replace the battery to avoid personal injury Due to energy hazard please remove wristwatches and jewelry such as rings whenreplacing battery BATTERY CONNECTION REQUIRED BEFORE USE Connecting the Battery 350VAand 500VA models 12V 5AH battery Pull out the battery onto a flat stable surface and connect the black battery cable to the battery terminal Push the topcenter edge ofbattery cover forward and remove the battery cover Pull out the battery onto aflat stable surface and connectthe black battery cable to the battery terminal Push the topcenter edge ofbattery cover forward and remove the battery cover Reinstall the battery into the UPS Reinstall the battery cover INSTALLATION AND OPERATION
7. hat are sentthrough the USB port 8 Circuit Breaker resetable The button protrudes whenan overload condition occurs If the button protrudes disconnectsome non essential equipment and reset the circuit breaker by pushing the button inward 9 Power Cord Australian plug type detached 1 8 meter line cord BATTERY REPLACEMENT PROCEDURE 1 Disconnect UPS system from power source 2 Open battery door 3 Disconnect used battery Connect new battery Itis important that connectors be firmly attached to new batteries 4 Close battery door 5 Properly recycle used battery 350VAand 500VA models 12V 5AH battery TROUBLESHOOTING Symptom Possible Cause Action to Take UPS will notturn on The battery is disconnected or utility power is not available at the wall outlet Connect the battery see Connect Battery and ensure power is available at the wall outlet Input Circuit Breaker has tripped Reduce the amountof equipment plugged into the outlets of the UPS Next reset the circuit breaker by pushing the plunger back in ei oaks Sogea STATUS INDICATORS The UPS provides both visual and audible status indicators Visual indicators consist of two LEDs to represent the following conditions e On utility power operation e On battery power operation e UPS fault alarm LED amp Alarm Status Table
8. the battery before continuing onbattery opera tion Equipment is connected to the surge Protection outlets Ensure the equipment that is to be protected from a power outage is plugged into the Battery Backup amp Surge Protection outlets The UPS mayrequire service Contact Powerware Technical Support SERVICE AND SUPPORT For service andsupport please callyour local distributoror the Powerware Australia National Service and Repair Centre Australia freecall 1300 303 059 Please have the following information ready e Model number and serial number e Symptoms of failure or problem e Customer contact information For additional information and to register your warranty please visit Www powerware com au Register your warranty within 30 days and receive an extended pro rated warranty and load protection guarantee Eaton Power Quality Pty Ltd 119 127 Wicks Road North Ryde NSW 2113 ETN Powerware MA6B412005 2005 01 12