Home

Planet Technology 170S8FS User's Manual

image

Contents

1. Copper To configure the device through Terminal Emulation Program via RS 232 serial RED port Indicator Console Zu Port e10 100Base TX Port To configure the device through Web Browser or TELNET program via LAN Ethernet 3 2 LED Indicators There are two powers at the rear and will indicate on the front panel the status of the power and fan PWROn Lights Green PWR Fail Lights Amber console Blinks Green when the data is transmitting Blinks Amber_ when transmitting the wrong data Lights Green when link to networking Ethernet Be Blinks Green when link is activit Chapter 4 CONFIGURING THE SYSTEM This chapter provides network managers and system administrators with information about how to configure the WMC 1600R via the Management interface 4 1 Configure Through Terminal Emulator TELNET Program 4 1 1 Console and Terminal Emulator program setting The WMC 1600R can be accessible using a terminal or terminal emulator attached to the RS 232 serial port 1 Locate correct DB9 serial port cable with female DB9 connector 2 Attach the DB9 serial port female cable connector to the male DB9 serial port connector on the chassis system 3 Attach the other end of the DB9 serial port cable to a remote the workstation 4 By default the Management Module uses the following serial port parameter values Bits per second 57600 Stop bits 1 Data bits 8 Parity NONE Flow Control NONE The default Lo
2. 11 sw 4 1 3 2 3 Media Converter Chassis Plugin Power Fail Fan Fail Power 1 V x X Power 2 y The screen will show out the power status of the WMC 1600R V stands for yes and X stands for No Plug in indicates if Power 1 or 2 was plugged in or not Power Fail indicates if the Power 1 or 2 is fail or not Fan Fail indicates if the Fan 1 or 2 is fail or not 4 1 3 2 4 Media Converters Configuration Media Converters Status Media 1 Media 2 Slot Name Plugin Link Dup Speed Fall Link Dup Speed Fail 01 Slot a a 02 Slot 03 Slot3 10 100TX 100 O4 Slot4 S1000T 10 Slot5 100TX 100FXS Slot6 Slot S10001 1000S X Slot8 1001X 100FXS Slot9 S1000T 1000SX x x 100M F 108 x e a z gt de ee are e e ee x x x x Y X Indicates the Link Duplex mode Speed and Fail status of each media converter 4 1 3 2 5 Media Converters Setting This screen is to set the Device function of LLCF and Link Enable the Media 1 LLR function Auto Negotiation Speed Duplex Mode Flow Control and Link Enable the Media 2 LLR function Auto Negotiation Duplex mode and Link Enable The in the screen stands for N A not available and the management interface will detect if the slot has the function in it and will let you set the function exist on the media converter slot Select the slot and press the space bar button to choose which function to open up t2 1 Devi
3. C Humidity Operating 10 90 Storage 5 90 Overload All outputs protected from short circuit condition automatic Protection recover Emissions FCC Class A CE Mark Class A VCCI Class A 21 H Management Module IEEE802 3 10Base T Ethernet Standards IEEE802 3u 100 Base TX Fast Ethernet IEEE802 3x flow control CSMA CD Data Ethernet 10Mbps half duplex 20Mbps full duplex Fast Transfer Rate Ethernet 100Mbps half duplex 200Mbps full duplex LED Indicators Power On Power Fail Fan Fail MGM Console LNK ACT 10BaseT 2 pair UTP Cat 3 4 5 EIA TIA 568 100 ohm STP 100Base TX 2 pair UTP Cat 5 EIA TIA 568 100 ohm STP Fixed Ports 1 x 10 100Base TX port 1 x 9 pin RS 232 Console port Power 3 watts Max Consumption Temperature operating 0 50 C Storage 10 70 C Humidity Operating 10 90 Storage 5 90 FCC Class A CE Mark Class A VCCI Class A 2 Part No EM WMCv1
4. Chapter 2 UNPACKING AND INSTALL 3 2 1 Unpacking 3 2 2 Installation 3 2 3 Deciding How to Install the System 3 Chapter 3 IDENTIFYING FRONT PANEL 7 3 1 Front Panel 7 3 2 LED Indicators 7 Chapter 4 CONFIGURING THE SYSTEM 4 1 Configure Through Terminal Emulator TELNET Program 9 4 2 Management through Web browser 15 Chapter5 TECHNICAL SPECIFICATIONS 21 Chapter 1 Introduction 1 1 Briefing The Intelligent Media Converter Chassis WMC 1600R series provides 16 slot and one management system in the 19 rack chassis The management function enable network administrator to monitor the media converter connection status and configure the converter via SNMP agent Telnet and Web remotely or via RS 232 console port yet eases the maintenance of media conversion The WMC 1600R series media converter chassis allows the connectivity of up to sixteen PLANET Smart Fast Gigabit Ethernet Converter in one chassis With the independent power supply on each slot of the WMC 1600R series you can freely install or remove the converters without interrupting the rest of the networks Moreover it s very flexible that each bay of the media converter chassis can be deployed with PLANET s smart media converter family Redundant power supply is also provided to enhance the reliability with option of either 100 240V AC power or 48V DC power 1 2 Features e High quality 19 Rack Mountable Chassis installation e Supports up to sixteen slide in modular med
5. Intelligent Media Converter Chassis WMC 1600R WMC 1600R43 User s Manual Trademarks Copyright PLANET Technology Corp 2002 Contents subject to revision without prior notice PLANET is a registered trademark of PLANET Technology Corp The information in this manual is subject to change without notice All other trademarks belong to their respective owners FCC Warning This equipment has been tested and found to comply with the regulations for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures REVISION User s manual for PLANET Intelligent Media Converter Chassis For Models WMC 1600R WMC 1600R48 Rev 1 0 Dec 2002 Part No EM WMCvi Table of Contents Chapter 1 INTRODUCTION 1 1 1 Briefing 1 2 Features Rh e
6. LATTE Step 3 Proceed to the Connecting to Power section 2 3 2 Installing Media Converter The chassis is equipped with sixteen media converter carriers each of which is fitted into bays of the chassis Step 1 To install a media converter module onto the chassis you have to unscrew the bay cover from the desired bay first Step 2 Unscrew the hand screw counter clockwise by using hand or screwdriver and pull out the media converter out the carrier as shown below TI Unscrew the hand screw counter clockwise by using hand or screwdriver and pull the media converter module out on the carrier NE Step 3 Carefully slide in the module and fasten the hand screw clockwise by using hand or screwdriver until it is fully and firmly fitted into the slot of the chassis Insert the media converter module into an available slot and fasten the hand screw clockwise by using hand or screwdriver 2 3 3 Connecting to Power Power Supply The chassis ships with only one power supply and a second power supply option is at your discretion When the chassis is equipped with two power supplies you can have the following advanced performance Hot Swappable The design of the power system is based on an idea of providing maximum flexibility and redundancy In this way you may remove any of the two power supplies without turning off the system Redundancy During operation both power supplies are switched on and sh
7. are the current load In case that one of them should fail the other will instantaneously take 100 of the load without any loss Similarly if one power supply is removed from servicing it can be switched off and removed while the chassis continues functioning Protection System The power of each converter bay comes from the two shared power supplies Each bay is isolated from each other under a certain protection mechanism so that it is free from any problem that might occur to the power supplies or faulty converter bay This is the best solution to protect your investment in media converters Note There is an optional solution for the backup power 48 volt DC to DC Power Supply The chassis system is equipped with one power supply and allows one additional power supply for redundancy For reliable operation we suggest that you run the chassis system with two power supplies are in place Step 1 Connect the supplied AC power cord to the back of the chassis Step 2 Attach the plug into a standard AC outlet with a voltage range from 100 240 VAC Step 3 Turn on the chassis system by flipping the switch beside the receptacle to ON position The LED on the front panel of power supply will come on then st 2 3 4 Installing and Removing the Power Supply To remove a power supply out the chassis you have to loose the hand screw counter clockwise and pull out the power supply from the chassis To install a power supply to th
8. ator password Confirm Password to confirm the setting of administrator password lI6 gg System Name to authorize the device system name Location to show the WMC 1600R where it is located Refresh time to set the refreshing time of the device through the web NOTE After configuring the system device need to press the save button to save the setting 4 2 2 2 System Configuration MAC Address 00 30 4f 47 f2 aa MAC Address will show out the MAC address of the Management interface IP Address to allocate an IP address for the Management interface the default IP is 192 168 1 1 Subnet Mask to set the Subnet Mask the default is 255 255 255 0 Default Gateway to set the gateway address the default is 192 168 1 254 NOTE After configuring the system device need to press the save button to save the setting 4 2 2 3 SNMP Configuration Cold Stan Trap GO Enable O Disable Warm Star Trap GO Enable O Disable Authentication Fall Trap 3 Enable O Disable PowerfFail Trap O Enable O Disable FanFallTiapt Enable ODisable MEPlugin Trap Enable O Disable MC Palas O Enable Disable EGG Enable O Disable CIK O Enable Disable MONDS Enable O Disable AR RS Get Community Name to get the device community name default public Set Community Name to set the device community name defaul
9. be subjected to extreme temperatures humidity or electromagnetic interference Specifically the site you select should meet the following requirements The ambient temperature should be between 32 and 104 degrees Fahrenheit 0 to 40 degrees Celsius The relative humidity should be less than 90 percent non condensing Surrounding electrical devices should not exceed the electromagnetic field RFC standards for IEC 801 3 Level 2 3V M field strength Make sure that the equipment receives adequate ventilation at the rear Do not block the fan exhaust holes on the rear of the chassis The power outlet should be within 1 8 meters of the chassis 2 3 Deciding How to Install the System We strongly suggest that you install the chassis first as this is more convenient for you to install media converters into the chassis with ease The accessories supplied in the product package include rack mount screws 8 pcs and rack mount brackets 2 pcs This well built chassis can be installed in the following ways 3 2 3 1 Mounted to 19 inch standard rack Use the rack mount brackets and screws to install the chassis into any EIA 19 standard rack Step 1 Attach the brackets to each side of the chassis Apply four screws to each side and secure them tightly Step 2 Carefully position the chassis into the rack Align the brackets to the side holes on the rack and use rack screws to secure the chassis with the rack
10. ce LLCF Link Loss Carry Forward on or off Enable to enable the link of the Device on or off Media 1 LLR Link Loss Return on or off Auto A for Auto Negotiation or F for forced Mode Speed to select the speed of the copper port 10M 100M or 1G Dup Duplex mode F for Full Duplex or H for Half Duplex FC Flow Control on or off Enable to enable the link of the Media 1 on or off Media 2 LLR Link Loss Return on or off Auto A for Auto Negotiation or F for forced Mode Dup Duplex mode F for Full Duplex or H for Half Duplex Enable to enable the link of the Media 1 on or off Note Some of the function can be control only depends on the Smart Media Converter 4 1 3 2 6 Redundant Backup Setting Group Act Master Slave i Disable i Restart 02 Disable 3 Restart 03 Disable i 6 Restart Disable f Restart gt Disable Restart Disable 1 i Restart 7 Disable 2 Restart D sable 9 Restart The redundant function is to change the master line to the slave line in case of the linking fails happen The Redundant functions were set fixed the master slot is slot 1 odd number slot and the slave slot is slot 2 even number slot and there are eight redundant groups in all The Act will indicate what slot is active When the
11. e chassis you have to fasten the hand screw clockwise and slide in the power supply to the chassis You can slide in and out the power supply from the bay fasten or loose the hand screw clockwise or counter clockwise by using hand or screwdriver Note If the Chassis System needs to work alone you can stick up four Rub ber foot below the chassis 2 3 5 Power Notice 1 The device is a power required device it means it will not work till it is powered If your networks should active all the time please consider using UPS Uninterrupted Power Supply for your device It will prevent you from network data loss or network downtime 2 In some area installing a surge suppression device may also help to protect your switch from being damaged by unregulated surge or current to the media converter eg Chapter 3 IDENTIFYING FRONT PANEL This section identifies all the major components of the front panel The front panel is shown followed by a description of each panel feature The indicator panel is described in detail in the next chapter 3 1 Front Panel The figure below shows the front panels of the Management Module The LED indicators of the Management Module include Power On Power Fail Fan Fail MGM Console and Link ACT The following shows the LED indicators for the Switch along with an explanation of each indicator eLED Indicator Panel Refer to the next section for detailed information eConsole Port RS 232
12. ected 4 13 i 4 2 2 5 Redundant Backup Setting Group ACE Master Slave Restart HEE O Enable ODisable WEHEN NREN O Enable Disable NE OEnable Disable HAZ O Enable O Disable B53 OEnable O Disable NEN OEnable Disable HE O Enable O Disable 82 O Enable O Disable O ar Hm Hti a o m Nim The redundant function is to change the master line to the slave line in case of the linking fails happen The Redundant functions were set fixed the master slot is slot 1 odd number slot and the slave slot is slot 2 even number slot and there are eight redundant groups in all The Act will indicate what slot is active When the slave slot is active and we need to transfer again to the master slot we need to push on the restart button 19 41210 Chapter 5 TECHNICAL SPECIFICATIONS Chassis System Capacity Sixteen bays for housing up to sixteen media converters One power supply provided hot swappable A second power supply for load sharing is optional also hot swappable cooling fans mounted together with the power supply or alone at the rear Dimensions W415 mm x D 390mm x H89 mmStandard 19 size 2 U Net Weight 7 2kg approx Only one power supply included Fan Dimensions 80 x 80 x 25 mm Power Supply Inputs 100 to 240 VAC universal power supplyor 48V DC Power 150 watts max Consumption Temperature Operating 0 40 C Storage 10 50
13. en plugged in default enable MC Pullout Trap to set the trap when the Media Converter module has been pulled out default enable MC Broken trap to set the trap when the Media Converter module was broken default enable MC Link up trap to set the trap when a linking is connected default enable MC Link down trap to set the trap when a linking is disconnected default enable MC Active Slot Xchg trap to set the trap when there is a redundant function activated default enable MC Active Slot Lose trap to set the trap when the redundant function is fail default enable 4 2 Management through Web browser The WMC 1600R is accessible using a Web browser IE explorer Netscape Communications etc to open up the chassis monitoring system The default IP Address for the chassis system is 192 168 1 1 and the default Login name and password is both root After enter its web interface the Home Page will show out the page for general configuration To set the management system click on the left side menu System Function and Configuration the center screen will then show the status and configuration screen for the menu you clicked on the left side Y PLANET Intelligent Media Conv Click on the Media Converter slot and it will appear a screen for you to monitor or control depend on what media converter you are using Sp 4 2 1 System Function There are fo
14. gin name and password is both root 4 1 2 TELNET program setting The WMC 1600R can be accessible using TELNET through LAN 1 Run TELNET program 2 Enter the IP address 192 168 1 1 the factory default IP address setting 3 The default Login name and password is both root 9 4 1 3 Management Setting Through Terminal Emulator There are three items in the Main Menu System Function Configuration and SNMP Configuration System Function Configuration snmp Configuration 4 1 3 1 System Function There are three items in System Function menu Software Reboot Factory Reset and Image Update Software Reboot Factory Reset Image Update 4 1 3 1 1 Software Reboot After configuring it needs to reboot the software setting in order to run the device properly 4 1 3 1 2 Factory Reset This function is to set the device back to the default setting in case of the messy setting 4 1 3 1 3 Image Update FIP Server IP Address HEAT Update File mcimage The section is to set the TFTP Server IP Address first and the default address was set to 192 168 1 2 The Image File can be updated by uploading the image file from the TFTP server Note The content of the image file will write the whole firmware of the man agement module please be sure that the image file is correct 4 1 3 2 Configuration To set the Software Reboot Factory Reset and Image Update eneral Configuratio System Confi
15. guration Media Converter Chassis Media Converters Status Media Converters Setting Redundant Backup Setting H 10 i There are four items in the Configuration menu General Configuration System Configuration Media Converter Chassis and Media Converters 4 1 3 2 1 General Configuration Hardware revision A2 BIOS revision 1 91 Firmware revision 1 10 Change Password ll Confirm Password System Name Location I Refresh Time l 5 Hardware revision noted the version of the hardware BIOS revision noted the version of the BIOS Firmware revision noted the version of the firmware Change Password the changing of the admit password Confirm Password to confirm the setting of admit password System Name to authorize the device system name Location to show the device where it is located Refresh time to set the refreshing time of the device through the web 4 1 3 2 2 System Configuration as Address 00 30 4f 47 92 53 IP Address BEI 168 l 1_ Subnet Mask 259 259 259 Default GW 1192 168 1 254 MAC Address will show out the MAC address of the device IP Address to allocate an IP address for the device the default IP is 192 168 1 1 Subnet Mask to set the Subnet Mask the default is 255 255 255 0 Default Gateway to set the gateway address the default is 192 168 1 254 NOTE After configuring the system device need to press the save button to save the setting
16. ia converters hot swappable e Two power slots for redundant power support with options of 100 240V AC or 48V DC e Reduce the effort of converter maintenance and management diagnose the status at one time e Two fans brings the air flow for system cooling and LED indicators for system and fan status e Bay power isolation ensure each bay is electrically isolated from each other e Support PLANET smart series Fast Ethernet and Gigabit Ethernet Media Converter e One 10 100Mbps Fast Ethernet port and one RS 232 port for management e Configurable through console Telnet and Web and SNMP e Provide the status of power fan and converters with SNMP trap function for any chassis and connectivity events 1 JH Chapter 2 UNPACKING AND INSTALL This chapter provides unpacking and setup information for the Media Converter Chassis 2 1 Unpacking Open the box of the WMC 1600R and carefully unpack it The box should contain the following items e One Intelligent Media Converter Chassis with one power supply installed e One RS 232 Cable e One Power Cord e CD ROM e Rack mounting Kit e This User s Manual If any item is found missing or damaged please contact your local reseller for replacement 2 2 Installation The site where you place the chassis system may greatly affect its performance When installing take the following into your consideration As with any electric device you should place the equipment where it will not
17. slave slot is active and we need to transfer again to the master slot push on the restart button 4 1 3 3 SNMP Configuration Get Community Name MAT Set Community Name private rap Community Name public Trap Host IP Address 192 168 1 2 Cold Start Trap Enable Warm Start Trap Enable Authentication Fail Trap Enable Power Fail Trap Enable Fan Fail Trap Enable MC Plugin Trap Enable MC Pullout Trap Enable MC Link Up Trap Enable MC Link Down Trap Enable MC Broken Trap Enable MC ACTIVE SLOT XCHG TRAP Enable MC ACTIVE SLOT LOSE TRAP Enable Get Community Name to get the device community name default public Set Community Name to set the device community name default private Trap Community Name to authorize the device trap community name default public Trap Host IP Address to set the trap host IP address Same as monitoring station IP address Cold Start trap to set the trap for rebooting the device default enable Warm Start trap to set the trap when the device had been reset default enable Authentication Fail Trap to set the warning trap when the community name of the device and workstation are different default enable Power Fail Trap to set the Power Fail Trap default enable Fan Fail Trap to set the fan fail trap default enable MC Plug in Trap to set the trap when a Media Converter module has be
18. t private Trap Community Name to authorize the device trap community name default public Trap Host IP Address to set the trap host IP address same as monitoring station IP address Cold Start trap to set the trap for rebooting the device default enable 11 sw Warm Start trap to set the trap when the device had been reset default enable Authentication Fail Trap to set the warning trap when the community name of the device and workstation are different default enable Power Fail Trap to set the Power Fail Trap default enable Fan Fail Trap to set the Fan fail trap default enable MC Plug in Trap to set the trap when a Media Converter Module has been plugged in default enable MC Pullout Trap to set the trap when the Media Converter Module has been pulled out default enable MC Broken trap to set the trap when the Media Converter Module was broken default enable MC Link up trap to set the trap when a linking is connected default enable MC Link down trap to set the trap when a linking is disconnected default enable MC Active Slot Xchg trap to set the trap when there is a redundant function activated default enable MC Active Slot Lose trap to set the trap when the redundant function is fail default enable 4 2 2 4 Location Setting mas a Assign each slot s location or name in order to remember in where each slot was conn
19. ur items in System Function menu Software Reboot Factory Reset Image Update and Configuration Update 4 2 1 1 Software Reboot Reboot the management module in order to run the new setting properly 4 2 1 2 Factory Reset This function is to set the device back to the default setting in case of the messy setting 4 2 1 3 Image Update The section is to set the TFTP Server IP Address first and the default address was set to 192 168 1 2 The Image File can be updated by uploading the image file from the TFTP server Note The content of the image file will write the whole firmware of the man agement interface please be sure that the image file is correct 4 2 1 4 Configuration Update The section is explaining how to upload and download the configure setting of the management interface The Configuration Upload is to restore a setting file to the management interface The Configuration Download is to backup the setting from the management interface 4 2 2 Configuration There are five items in Configuration menu General Configuration System Configuration SNMP Configuration Location Setting and Redundant Backup Setting 4 2 2 1 General Configuration Hardware revision A2 BIOS revision 1 01 Firmware revision 1 11 Hardware revision noted the version of the WMC 1600R BIOS revision noted the version of the BIOS Firmware revision noted the version of the firmware Change Password the changing of the administr

Download Pdf Manuals

image

Related Search

Related Contents

SOVOS 5” E-Reader Plus SVEBK5 User Guide  How to reset SMS-530  K118取扱説明書を見る  Rockford Fosgate R152 User's Manual  Exhibitor Service Manual  User Guide TWS Alerter R2.1  M12-896D GPS Watch User Manual Introduction Getting  LEDライト  Manual de instrucciones y funcionamiento  Manuale utente Cleopatra  

Copyright © All rights reserved.
Failed to retrieve file