Home

Perle Systems C-1000MM-XXXXXX User's Manual

image

Contents

1. 17 15 CM 1000MM M2SC05 RX 850 Max 4 Max 3 Fiber port 2 MM2 SM2 Wave TX RX Model Mode length Power Power ds nm dB dB C 1000MM M2SCO05 MM TX 850 Min 9 5 Min 17 15 CM 1000MM M2SC05 RX 850 Max 4 Max 3 C 1000MM M2ST05 MM TX 850 Min 9 5 Min 17 75 CM 1000MM M2ST05 RX 850 Max 4 Max 3 i C 1000MM M2LC05 MM TX 850 Min 9 5 Min 17 15 CM 1000MM M2LCO05 RX 850 Max 4 Max 3 C 1000MM S2SC10 SM TX 1310 Min 9 5 Min 20 10 5 CM 1000MM S2SC10 RX 1310 Max 3 Max 3 C 1000MM S2ST10 SM TX 1310 Min 9 5 Min 20 10 5 CM 1000MM S2ST10 RX 1310 Max 3 Max 3 i Gigabit Fiber to Fiber Media Converter Module Installation Guide 14 C 1000MM M2LC10 SM TX 1310 Min 9 5 Min 20 10 5 CM 1000MM M2LC10 RX 1310 Max 3 Max 3 i C 1000MM S2SC40 SM TX 1310 Min 3 Min 23 20 CM 1000MM S2SC40 RX 1310 Max 5 Max 3 C 1000MM S2ST40 SM TX 1310 Min 3 Min 23 20 CM 1000MM S2ST40 RX 1310 Max 5 Max 3 C 1000MM S2LC40 SM TX 1310 Min 3 Min 23 20 CM 1000MM S2LC40 RX 1310 Max 2 Max 3 C 1000MM S2SC70 SM TX 1550 Min 2 Min 23 21 CM 1000MM S2SC70 RX 1550 Max 5 Max 3 C 1000MM S2ST70 SM TX 1550 Min 0 Min 23 23 CM 1000MM S2ST70 RX 1550 Max 5 Max 3 C 1000MM S2LC70 SM TX 1550 Min 0 Min 23 23 CM 1000MM S2LC70 RX 1550 Max 5 Max 3 C 1000MM S2SC120 SM TX 1550 Min 0 Min 3
2. Systems Gigabit Fiber to Fiber Media Converter Module Installation Guide 17
3. its internal flash memory to see if configuration information has been downloaded to it from a management module If so it will use this as its running configuration If there is no configuration in flash it will read the settings of the DIP switches and use those as its running configuration SW Pin 1 and Pin 2 are strapped When set to SW Switch the module will at power up read the settings of the DIP Switches and use those as it running configuration It will ignore any configuration information in its flash memory NOTE The default jumper setting is Auto Pini Pin2 Pin3 e SW AUTO Gigabit Fiber to Fiber Media Converter Module Installation Guide A DIP Switch Settings 1 Fiber Negotiation 2 Link Mode 3 Fiber Fault Alert 4 Remote Loopback Fiber 1 5 Remote Loopback Fiber 2 sm Fiber Negotiation Switch 1 Switch Position Mode Up default Auto Down Off Auto In this mode of operation the Media Converter will negotiate fiber parameters on both MM1and MM2 SM2 fiber ports This will ensure the most optimal connection parameters will be in effect If connecting to another Perle media converter this parameter should be set to Auto Off Fiber negotiation on both fiber ports will be disabled Fiber Negotiation should only be turned off if the fiber link partner does not support fiber link negotiations Gigabit Fiber to Fiber Media Converter Module Ins
4. 1550 nm n us SC SUES loan 40km 24 9 mi 1550 nm Gigabit Fiber to Fiber Media Converter Module Installation Guide 2 Wavelength CM 1000MM M2xx05 Model Connector Mode Distance TX RX C 1000MM S1SC10U CM 1000MM SISCIQU SC SM 10 km 6 2 mi 1310 1490 nm pte dc SC SM 10 km 6 2 mi 1490 1310 nm Note 2 Please refer the Perle web site for the most up to date Installation guides models and specifications http www perle com Gigabit Fiber to Fiber Media Converter Module Installation Guide 3 Installation The default switch settings all switches in the UP position will work for most installations See the Operation section of this guide for more details The module comes equipped with a bank of DIP switches and jumpers for setting configuration The default DIP switch settings all switches in the UP position and jumper setting will work for most installations The following steps are used to configure the Perle Gigabit Fiber to Fiber Media Converter Module 1 Set the Auto Config jumper CM 1000MM only optional Set the DIP switch settings optional Insert the Media Converter Module into the chassis e 0I Connect the fiber cables Auto Config Jumper CM 1000MM only The Auto Config jumper is J5 Refer to the diagram below for labelling Auto Pin 2 and Pin 3 are strapped When set to Auto the module will at power up check
5. 2 32 CM 1000MM S2SC120 RX 1550 Max 5 Max 9 C 1000MM S2S T120 SM TX 1550 Min 0 Min 32 32 CM 1000MM S2ST120 RX 1550 Max 5 Max 9 C 1000MM S2LC120 SM TX 1550 Min 0 Min 32 32 CM 1000MM S2LC120 RX 1550 Max 5 Max 9 C 1000MM S1SC10U SM TX 1310 Min 9 Min 20 11 CM 1000MM S1SC10U RX 1490 Max 3 Max 3 C 1000 S1SC10D SM TX 1490 Min 9 Min 20 T CM 1000 S1SC10D RX 1310 Max 3 Max 3 Fiber Cabling Requirements MM 50 125 microns or 62 5 125 microns SM 9 125 microns Note Please refer the product page on the Perle website for the most up to date models and specifications http www perle com Gigabit Fiber to Fiber Media Converter Module Installation Guide 15 Compliance Information FCC This product has been found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions in this Guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his her own expense EN 55022 Class A WARNING This is a Class A product In a domestic e
6. Perle Gigabit Fiber to Fiber Media Converter Module Installation Guide C 1000MM XXXXXX Unmanaged Module CM 1000MM XXXXXX Managed Module P N 5500315 10 Overview This document contains instructions necessary for the installation and operation of the Perle Gigabit Fiber to Fiber Media Converter Module s that are used in conjunction with a Perle MCR chassis The C 1000MM media converters are unmanaged modules and the CM 1000MM are the managed converter modules These products allow dissimilar 1000Base X fiber interfaces to connect to one another For information on the management options of the CM 1000MM module refer to the MCR MGT Module User s Guide These are the fiber to fiber conversion models e Multimode to Multimode MM e Multimode to Single Mode SM e Multimode to Single Mode Single Strand MM The first fiber port will be multimode MM and the second fiber port can be either single mode SM or multimode MM depending on the model selected They can operate over different wavelengths and distances See tables below Fiber port 1 MM 1 Model Connector Mode Distance EC tae All models SC STILC MM 550 m 1804 ft 850nm Fiber port 2 MM2 SM2 Model Connector Mode Distance EROR EE CAL ONO Aeros SCISTLC MM S5SOm IS04f 850 nm EM ERN SC STILC SM 10 km 6 2 mi 1310nm anon SC STILC SM 40km249 mi 1310 nm EM ue SC STILC SM 70km A3 5 mi
7. Test e On Power is on module is operating normally e Blinking slowly the module is in loopback mode e Blinking quickly the module has a hardware error LK1 MM1 Fiber Link10 Activity e On Fiber link present e Blinking quickly Fiber link present and receiving data e Blinking s owly The fiber link has been taken down as a result of Smart Link Pass Through e Off No fiber link LK2 MM2 SM2 Fiber Link 2 Activity e On Fiber link present e Blinking quickly Fiber link present and receiving data e Blinking s owly The fiber link has been taken down as a result of Smart Link Pass Through e Off No fiber link Gigabit Fiber to Fiber Media Converter Module Installation Guide 12 Troubleshooting General Ensure the module is securely seated in the chassis The PWR LED on the module should be on solid Ensure all cabling is of the correct type and is in good operating condition Ensure both devices on either end of the fiber are compatible If using a simplex fiber connection ensure that you have both an Upstream U and Downstream D Media Converters For dual stranded fiber connections ensure the RX and TX has been reversed between the two Media Converters No connectivity If unable to get full connectivity with all DIP switches in the UP position these methods are recommended for troubleshooting Method 1 1 Turn off Fiber Negotiation SW1 Down on both media converters Leave all other s
8. damaged or incorrectly aligned pins If these are not damaged retry module insertion Tighten the captive retainer screw to ensure the Media Converter Module is locked in place Remove the dust cap from the fiber connector and connect the fiber and copper cables Gigabit Fiber to Fiber Media Converter Module Installation Guide 9 captive retainer screw Removing Media Convert Modules 1 Loosen the captive retainer screw on the front of the Media Converter Module and gently pull the module out 2 If not inserting a replacement Media Converter Module then cover the opening slot with a face plate and secure the screw Installing the Duplex Fiber Cable 1 Locate a 1000Base X compliant duplex 2 strands fiber cable with appropriate connectors 2 Connect the fiber cables from one Converter to the other Converter switch fiber device ensuring that the RX and TX are reversed at the opposite end Gigabit Fiber to Fiber Media Converter Module Installation Guide 10 Installing the Simplex Fiber Cable 1 Locate a 1000Base X compliant simplex 1 strand fiber cable with appropriate connectors 2 Connect the fiber cable from one Converter to the other Converter switch fiber device Gigabit Fiber to Fiber Media Converter Module Installation Guide 11 Operation Status LED The Perle Gigabit Media Converter Modules have three single colored status LEDs located on the face plate of the module PWR Power
9. enabled this switch is ignored Gigabit Fiber to Fiber Media Converter Module Installation Guide 6 Illustration of the FFA eg ST End zm End Device 4 0 EE ER Device Fiber Port 1 x Port 1 aL Port 2 sm ic 2 MMI MM2 Media Converter A Configuration Link Mode Standard Mode Fiber Fault Alert Media Converter B Configuration Link Mode Smart Link Pass Through Mode Fiber Fault Alert Sequence of Events 1 Media Converter A loses fiber connection RX on MM2 SM2 2 Media Converter A disables the transmitter TX MM2 SM2 3 Media Converter B detects loss of fiber link on receiver RX MM2 SM2 Media Converter B turns off transmitter TX on MM1 5 Media Converter A MM1 is not affected Gigabit Fiber to Fiber Media Converter Module Installation Guide 7 Remote Loopback Fiber 1 Switch 4 Switch Position Mode Up default Disabled Down Enabled Disabled The loopback feature is disabled This is the normal position for regular operation The switch must be set to this position in order for data to pass through the Media Converter Module Enabled This is a test mode All data received on the receive RX fiber connection is looped back to the transmit TX fiber connection Note Only one fiber interface can be in loopback at a time Remote Loopback Fiber 2 Switch 5 Switch Position Mode Up default Disabled Down Enabled Disab
10. led The loopback feature is disabled This is the normal position for regular operation The switch must be set to this position in order for data to pass through the Media Converter Module Enabled This is a test mode All data received on the receive RX fiber connection is looped back to the transmit TX fiber connection Note Only one fiber interface can be in loopback at a time Gigabit Fiber to Fiber Media Converter Module Installation Guide 8 Installing Media Converter Modules Caution Observe electrostatic discharge precautions when installing the Media Converter Module s into the Chassis Failure to observe this caution could result in damage to the Module s and or chassis The Perle Media Converter Modules can be installed in any available slot and in any order within the chassis 1 2 Remove the Module from its packaging Using a cross head screwdriver remove the screw holding the face plate to the Chassis to reveal the slot opening Set the jumpers and DIP switches on the Media Converter Module to the desired operating mode optional Locate the top and bottom alignment guides inside the MCR Chassis Using the module alignment guides gently slide the module into the slot until it becomes flush with the front of the Chassis Light pressure may be needed to seat the module Do not force the module as you might cause damage If there is resistance remove the module and check the module connector for
11. nvironment this product may cause radio interference in which case the user may be required to take adequate measures EN 55024 Class A Laser Safety IEC 60825 1 2007 This product meets Class Laser safety requirements per IEC 60825 1 2007 standard and complies with FDA CDRH 21 CFR1040 10 and 21 CFR1040 11 WARNING Visible and invisible laser radiation may be present when cables are not connected Do not stare into the beam or view the beam directly with optical instruments Failure to observe this warning could result in an eye injury or blindness WARNING Use of controls adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure Gigabit Fiber to Fiber Media Converter Module Installation Guide 16 Warranty Registration Perle s standard Lifetime Warranty provides customers with return to factory repairs for Perle products that fail under the conditions of the warranty coverage Details can be found at http www perle com support services warranty shtml Contacting Technical Support Contact information for the Perle Technical Assistance Center PTAC can be found at the link below A Technical Support Query may be made via this web page www perle com support services support request shtml Copyright 2011 Perle Systems Limited All rights reserved No part of this document may be reproduced or used in any form without written permission from Perle
12. tallation Guide B Link Mode Switch 2 Switch Position Mode Up default Smart Link Pass Through Mode Down Standard Mode Smart Link Pass Through In this mode the link state on one connection is directly reflected through the Media Converter to the other connection If link is lost on one of the connections then the other link will be brought down Standard Mode In this mode the links can be brought up and down independently of each other A loss of link on either fiber connection can occur without affecting the other connection Fiber Fault Alert Switch 3 Switch Position Mode Up default Enabled Down Disabled Enabled If the media converter module detects a loss of fiber signal on the fiber receiver the media module will immediately disable its fiber transmitter signal on this port This in effect notifies the fiber link partner that an error condition exists on the fiber connection If the remote media converter module is set up for Fiber Fault Alert FFA Enabled and the local media converter is set up with Smart Link Pass Through a loss of fiber link on either the transmit or receive line will be passed through to the other fiber connection Disabled The media converter module will not monitor for fiber fault Note This feature is not required if Fiber negotiation has been enabled since link negotiation accomplishes the same thing When Fiber Negotiation is
13. witches UP 2 Connect the near end device to port MM1 the LK1 LED should be lit to indicate a good fiber connections If the LK1 LED is not lit then check the fiber cable and the attached device Repeat step 2 for port MM2 SM2 Return the media converter to the desired configuration Method 2 The fiber connection can also be verified by configuring the remote media converter for loopback mode The LEDs on both media converters should be lit Data should pass through the local converter then over the fiber connection to the remote media converter Gigabit Fiber to Fiber Media Converter Module Installation Guide 13 Note If troubleshooting a CM 1000MM setting the Auto Config jumper J5 to SW will ensure the DIP switches are being read Technical Specifications The following applies to all C 1000MM and CM 1000MM media converters Power Input Consumption Operating Temperature Storage Temperature Operating Humidity Storage Humidity Operating Altitude Weight MTBF C 1000MM MTBF CM 1000MM 12V DC 2 5 W OC 50 32F 122F 25 70 13F 158F 5 to 90 non condensing 5 to 95 non condensing Up to 3 048 m 10 000 ft 0 15 kg 0 33 Ibs 421 344 hours 417 722 hours Fiber Optic Specifications Fiber port 1 MM1 Wave TX RX Model Mode length Power Power EM nm dB dB C 1000MM M2SCO05 MM TX 850 Min 9 5 Min