Home
Pelco WCS1-4 User's Manual
Contents
1. 8 05 Revised manual per ECO 05 11280 to change input power and a fuse value from 230 VAC to 240 VAC C561M E 8 05 11 PELCO World Headquarters 3500 Pelco Way Clovis California 93612 USA USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120 www pelco com 1509001 Orangeburg New York Las Vegas Nevada Eindhoven The Netherlands Wokingham United Kingdom Montreal Canada Singapore
2. WCS1 4 power supply refer to Figure 4 and do the following 1 2 C561M E 8 05 Determine the size of the input wire needed Bring the wiring into the WCS1 4 through the conduit fitting Attach the neutral input power wire to the 100V 120V or 240V NEUTRAL connection on the Primary Line Input connector strip Attach the hot wire to the LINE connection on the same strip Attach the input ground wire to the No 6 ground stud located between the conduit holes and tighten the wire with the nut and washer supplied OUTPUT WIRING To install the output wiring to the camera dome or positioning system refer to Figure 4 and do the following 1 Refer to Table A and determine the output connection needed for your camera dome or positioning system Refer to Figure 4 for the proper connector strip connections 2 Attach one output wire to either the Tap A 24 VAC Tap B 26 VAC or Tap C 28 VAC connections on the Secondary Output Tap s connector strip and attach the second wire to the COM connection on the same strip Be sure that you have the proper wiring size and distances installed if you plan to change connections later 3 Close the lid to the WCS1 4 power supply replace the retaining screw to the door latch and then turn power on SPARE FUSES FUSE HOLDER INPUT TERMINALS OUTPUT TERMINALS GROUND STUD O Figure 4 Wiring Connector Diagram 6 C561M E 8 05 CABLE CONNECTIONS AND RE
3. 1 4 is a mutliple power supply designed for indoor or outdoor applications and is ideal for use with cameras domes and integrated positioning systems such as Spectra and Esprit The WCS1 4 is capable of powering up to four units and can handle pan tilt heater blower and camera operation The WCS1 4 power supply has one fused output and is capable of handling up to 4 amps 100 VA of total load The unit features selectable 100 120 240 VAC input power selectable 24 26 28 VAC output power and a stainless steel link lock latch that can be secured with padlock padlock not provided C561M E 8 05 3 INSTALLATION MOUNTING INSTRUCTIONS To mount the power supply directly to a wallboard wall or concrete refer to Figures 1 through 3 and do the following 1 Remove the retaining screw from the door latch of the WCS1 4 power supply 2 Open the door of the WCS1 4 power supply and then remove the plug s from the required conduit hole s located on the bottom of the unit Install 3 4 inch 1 91 cm conduit fitting s not supplied Close the lid to the power supply 3 Determine the mounting location for the WCS1 4 4 Use the WCS1 4 power supply as a template and mark the four fastener positions on the mounting surface 5 Prepare the holes for installation 6 Attach the WCS1 4 power supply securely to the mounting surface with four fasteners of appropria
4. 1H 2 and MC3651H 2X camera models which have a five year warranty e Two years on standard motorized or fixed focal length lenses e Two years on Legacy CM6700 CM6800 CM9700 Series matrix and DF5 DF8 Series fixed dome products e Two years on Spectra Esprit ExSite and PS20 scanners including when used in continuous motion applications e Two years on Esprit and WW5700 Series window wiper excluding wiper blades e Eighteen months on DX Series digital video recorders NVR300 Series network video recorders and Endura Series distributed network based video products e One year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months e Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products Pelco s iability for any claim whether based on breach of contract negligence infringement of any rights of any party or product li
5. 81 425 129 Tap C 28 VAC 77 23 122 37 195 59 311 94 493 150 C561M E 8 05 MAINTENANGE There are no user serviceable parts except for the fuse If the transformer in the WCS1 4 does not work properly the entire environmental power supply needs to be returned to the factory for repair Refer to the Warranty and Return Information for instructions on returning the WCS1 4 Clean the outer surface of the WCS1 4 box with a nonabrasive cleaning cloth and antistatic cleaner Do not use kerosene or similar substances that may damage the surface 8 C561M E 8 05 SPECIFICATIONS ELECTRICAL Input Voltage Output Voltage Power Fusing Spare Fuse Holder MECHANICAL Construction Finish Cable Entry Mount Method Latch GENERAL Environment Operating Range Weight Dimensions Selectable 100 120 240 VAC 50 60 Hz via the Primary Line Input connector strip Selectable 24 VAC Tap A 26 VAC Tap B or 28 VAC Tap C at 100 VA via the Secondary Output Tap s connector strip One fuse Select from one of the following supplied fuses Three 1 6 A fast acting fuses 120 VAC Three 500 mA fast acting fuses 240 VAC Two spare fuse holders attached to transformer cover Aluminum Gray polyester powder coat Two hole plugs will accommodate 3 4 inch 1 91 cm conduit fittings not provided that meet NEMA Type 4X standards Four 0 375 inch 0 95 cm holes on mounting plate One stainle
6. INSTALLATION OPERATION WCS1 4 Environmental Power Supply C561M E 8 05 IMPORTANT SAFEGUARDS AND WARNINGS 1 2 Read these instructions Keep these instructions Heed all warnings Follow all instructions Installation should be done only by qualified service personnel and conform to all local codes Use only installation methods and materials capable of supporting four times the maximum specified load Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Only use attachments accessories specified by Pelco Use only with the cart stand tripod bracket or table specified by Pelco or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as liquid has been spilled or objects have fallen into the apparatus the apparatus does not operate normally or has been dropped Only use parts recommended by Pelco Use stainless steel hardware to fasten the enclosure to outdoor surfaces AN ALL POLE MAINS SWITCH with a contact separation of at least 3 mm in each pole shall be incorporated in the electrical installation of the building permanent 240 VAC product only C561M E 8 05 DESCRIPTION The WCS
7. QUIREMENTS Table A Wiring Distances The following are the recommended maximum distances to wire the WCS1 4 to a Spectra Ill or Esprit positioning system To determine the correct voltage tap 1 Pick the unit type 2 Find the wire gauge used 22 gauge is not recommended 3 Determine which secondary output tap A B or C is appropriate for the distance between the dome or positioning system and the WCS1 4 Distance is in feet meters MAXIMUM DISTANCE FROM TRANSFORMER TO LOAD 20 AWG 18 AWG 16 AWG 14 AWG 12 AWG Spectra III Indoor 25 VA 0 5 mm 1 0 mm 1 5 mm 2 5 mm 4 0 mm Tap A 24 VAC 113 34 180 55 287 87 455 139 725 221 Tap B 26 VAC 133 40 212 64 337 103 536 163 852 260 Tap C 28 VAC 155 47 246 75 392 119 623 190 990 302 Environmental Spectra llland 20 AWG 18 AWG 16 AWG 14 AWG 12 AWG Esprit with 10C amp IOP 70 VA 0 5 mm 1 0 mm 1 5 mm 2 5 mm 4 0 mm Tap A 24 VAC 41 12 64 19 102 31 163 50 259 79 Tap B 26 VAC 49 15 78 24 124 38 198 60 315 96 Tap C 28 VAC 55 17 88 27 135 41 222 68 353 107 20 AWG 18 AWG 16 AWG 14 AWG 12 AWG Esprit 50 VA 0 5 mm 1 0 mm 1 5 mm 2 5 mm 4 0 mm Tap A 24 VAC 56 17 90 27 143 43 228 69 362 110 Tap B 26 VAC 66 20 105 32 168 51 268
8. ability relating to the Products hall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise he above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state a a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide he following information Model and serial number 2 Date of shipment P O number Sales Order number or Pelco invoice number 3 Details of the defect or problem there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS n order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods ret
9. ss steel link lock latch secured with screw latch also can be secured with padlock not supplied Indoor outdoor 50 F to 122 F 45 56 C to 50 C 6 5 Ib 2 95 kg See Figure 5 Design and product specifications subject to change without notice This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002 96 EC of the European Union regarding the disposal of waste electrical and electronic equipment WEEE Contact your local dealer for procedures for recycling this equipment Es C561M E 8 05 6 50 16 51 gt 5 63 14 30 ude Fe 4 50 11 43 gt j A 0 0 3 ak A 7 88 6 44 20 02 16 36 5 88 14 94 I Y O o o O 0 NOTE VALUES IN PARENTHESES ARE CENTIMETERS ALL OTHERS ARE INCHES Figure 5 WCS1 4 Dimension Drawing C561M E 8 05 WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below e Five years on FT FR8000 Series fiber optic products e Three years on Genex Series products multiplexers server and keyboard e Three years on Camclosure and fixed camera models except the CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC365
10. te length Fasteners between 1 4 inch and 5 16 inch diameter not supplied can be used MOUNTING HARDWARE WITH Jo WOOD SCREW MOUNTING song ico nse pp L fo E o sed DOOR DOORS DOOR LATCH LATCH LATCH o RETAINING RETAINING RETAINING pmm Ld ne i arene WALLBOARD WALL oe CONCRETE w w WALL Figure 1 Figure 2 Figure 3 Mounting to Mounting to Mounting to Concrete Wallboard Wall A WARNING Under light load conditions and high input power voltage output voltage from the WCS1 4 power supply may reach 32 VAC Pelco recommends that all equipment connected to the WCS1 4 power supply be rated to handle 32 VAC Pelco s Spectra domes and Esprit integrated positioning systems meet this require ment Pelco cannot be liable for any damages resulting from incorrect wiring of the WCS1 4 power supply C561M E 8 05 FUSE INSTALLATION The WCS1 4 power supply is shipped from the factory with a 1 6 amp fuse installed for 100 120 VAC input power To use input power of 240 VAC change the 1 6 amp fuse to a 500 milliamp fuse supplied To change the fuse remove the lid to the fuse holder refer to figure 4 located inside the power supply and then install the new fuse Store extra fuses supplied in the spare fuse holders INPUT POWER WIRING breaker before wiring the power supply A WARNING The WCS1 4 does not have an on off switch Turn off power at the circuit To install the input power wires to the
11. urned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below If you are located within the continental U S Alaska Hawaii or Puerto Rico send goods to Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 Ifyou are located outside the continental U S Alaska Hawaii or Puerto Rico and are instructed to return goods to the USA you may do one of the following If the goods are to be sent by a COURIER SERVICE send the goods to If the goods are to be sent by a FREIGHT FORWARDER send the goods to Pelco Pelco c o Expeditors 3500 Pelco Way 473 Eccles Avenue Clovis CA 93612 5699 USA South San Francisco CA 94080 USA Phone 650 737 1700 Fax 650 737 0933 Pelco the Pelco logo Spectra Genex Coaxitron Legacy Esprit Camclosure Spectra Ill and Spectra Ill SE are registered trademarks of Pelco Copyright 2003 Pelco All rights reserved REVISION HISTORY Manual Date Comments C561M 11 97 Original version C561M A 12 98 Changed model number Revised Table A to update vA ratings for Spectra 5 00 Changed model number C561M B 6 00 Revised manual to support changes required for UL listing C561M C 5 03 Revised Wiring Distance section to include Spectra III and Esprit information Updated manual to new format C561M D 11 03 Revised cover photo and Figure 5 to show new conduit hole plug per ECO 01 6947 C561M E