1. al line down each stud s center Center of screen mounting plate will be 2 5 offset from center of outer mounting slot as shown in figure 1 1 or will be 0 19 offset from center of inner mounting slot as shown in figure 1 2 Place wall arm A on wall as template level and mark the center of four mounting holes Top mounting slot will be X above the screen center as shown in figure 1 1 and chart 1 Drill four 5 32 dia holes to a minimum depth of 2 5 Secure wall arm A to wall with four wood screws D as shown in figure 1 2 NOTE Be sure arrow is pointing up when mounting wall arm A to wall as shown in figure 1 1 Level then tighten all fasteners Insert eight fastener caps G into wall plate mounting holes fig 1 1 fig 1 2 oe ARROW a 5 S S ES S S SCREEN SS _ MOUNTING PLATE amp CENTER OF SCREEN 4 of 10 ISSUED 10 01 10 SHEET 095 9354 3 12 13 10 Installation to Solid Concrete or Cinder Block A WARNING e When installing Peerless wall mounts on cinder block verify that you have a minimum of 1 3 8 35 mm of actual concrete thickness in the hole to be used for the concrete a
2. ghten screws firmly but do not overtighten Overtightening can damage the items greatly reducing their holding power This product is intended for indoor use only Use of this product outdoors could lead to product failure and personal injury This product was designed to be installed on the following wall construction only WALL CONSTRUCTION HARDWARE REQUIRED e Wood Stud Included Wood Beam Included Solid Concrete Included Cinder Block Included Brick Contact Qualified Professional Not evaluated by UL Other or unsure Contact Qualified Professional Not evaluated by UL Tools Needed for Assembly e stud finder edge to edge stud finder is recommended e phillips screwdriver e drill e 5 16 8 mm bit for concrete and cinder block wall e 5 32 4 mm bit for wood stud wall e level Table of Contents gt Parts Listesinin nnana is na a E T N EEE AE aAa A A eas Ea AEE meat caa N NE sient 3 Wal IAS CaN AU OM isc cies de Pees a T E A A A 4 5 Installing Adapter plates to SCrEGN c cccccceceeeeeeeeeeeceeceneaeeeeeeeeeeetee ee caaeaaeaeeeeeeeeeeeteeseceeaaeaeseeeeeeeesecaeaaeeaeeeeeeeeeeeeetecseesinsaeess 6 Mounting Flat Panel SCreeiaientiandereetentis nentt ea a edhe dent main dates 8 2 of 10 ISSUED 10 01 10 SHEET 095 9354 3 12 13 10 Before you begin make sure all parts shown are included with your product Parts List Description wall arm assembly upper mounting plate lower mounting plate wood screw conc
3. h display into eight mounting holes on bottom of display M5 CHROME SCREWS STANDOFFS Assemble upper mounting plate B to lower mounting plate C using four 10 32 x 1 2 thread forming screws K Use configuration as shown in figures 3 1 and 3 2 Do not tighten screws K FOR 46 DISPLAYS FOR 55 DISPLAYS 6 of 10 ISSUED 10 01 10 SHEET 095 9354 3 12 13 10 Set control box into lower mount plate C and place assembly onto back of display Adjust upper and lower mounting plates B C to align top mounting holes with ultra slim wall mount bar Secure assembly to back of display by reinstalling two M4 chrome plated screws included with display into ultra slim wall mount bar four M4 black phillips screws included with display into lower mounting holes of control box and four M4 x 16 mm phillips screws M into upper mounting holes of control box Tighten all fasteners ULTRA SLIM WALL MOUNT BAR DISPLAY Install two 1 4 20 x 1 2 thread forming screws L into lower mounting plate C leaving 1 8 exposed thread as shown below 7 of 10 ISSUED 10 01 10 SHEET 095 9354 3 12 13 10 Mounting Flat Panel Screen A WARNING e Tighten screws so screen brackets are firmly attached to screen Do not tighten with excessive force Overtightening can cause stress damage to screws greatly reducing their holding power and possibly causing screw heads to become detached Tighten to 40
4. in Ib 4 5 N M maximum torque O Hook two 1 4 20 x 1 2 thread forming screws L onto top slots of front plate as shown in figure 6 1 Fasten two 1 4 20 x 1 2 thread forming screws L into bottom mounting holes as shown in figure 6 2 Tighten all screws FRONT PLATE 8 of 10 ISSUED 10 01 10 SHEET 095 9354 3 12 13 10 Cable Management C Cables may be routed using short cable ties I Use holes on bottom of lower mounting plate C with cable ties I to secure cables as shown below Cables may be routed using cable clip H Slip cable clip H onto bottom of center joint as shown in figure 7 1 and secure cables to cable clip using long cable tie N as shown in figure 7 2 Secure cables to bottom of wall plate using cable tie N as shown below 9 of 10 ISSUED 10 01 10 SHEET 095 9354 3 12 13 10 Roll Adjustment O Adapter plate may be rolled 5 Loosen four M6 nylock nuts half a turn grasp edges of display and roll screen to desired position as shown Retighten four M6 nylock nuts and place four snap caps J onto M6 nylock nuts CAUTION e Do not tighten joint screws Doing so may cause damage to screws greatly reducing its holding power JOINT SCREWS i A gJ 8 ae a o 9 F 9 M6 NYLOCK NUTS 10 of 10 ISSUED 10 01 10 SHEET 095 9354 3 12 13 10 2009 Peerless Industries Inc Al
5. l rights reserved All other brand and product names are trademarks or registered trademarks of their respective owners
6. nchors Do not drill into mortar joints Be sure to mount in a solid part of the block generally 1 25 mm minimum from the side of the block Cinder block must meet ASTM C 90 specifications It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity Concrete must be 2000 psi density minimum Lighter density concrete may not hold concrete anchor e Installer must verify that the supporting surface will safely support the combined load of the equipment and all at tached hardware and components NOTE Wall arm assembly A must be mounted to wall using inner mounting holes Make sure that wall arm assembly is level and use wall plate as a template to mark four mounting holes Top mounting slot will be X above the screen center as shown in figure 1 1 and chart 1 on page 4 Drill four 5 16 8 mm dia holes to a minimum depth of 2 5 64 mm Insert anchors E in holes flush with wall as shown Place wall arm assembly over anchors and secure with wood screws D Level then tighten all fasteners Insert eight fastener caps G into mounting holes NOTE Be sure arrow of label is pointing up when mounting wall arm assembly A to wall as shown in figure 1 1 A WARNING e Tighten screws so that wall plate is firmly attached but do not overtighten Overtightening can damage screws greatly red
7. peer less Installation and Assembly Peerless Ultra Slim Articulating Mount for Samsung 46 and 55 C9000 LED displays Models SUAC9000 Max UL Load Capacity 75 Ib 34 kg 3215 W North Ave Melrose Park IL 800 865 2112 or 708 865 8870 Fax 708 865 2941 www peerlessmounts com ISSUED 10 01 10 SHEET 095 9354 3 12 13 10 NOTE Read entire instruction sheet before you start installation and assembly A WARNING Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet If you have any questions regarding any of the instructions or warnings for US customers please call Peerless customer care at 1 800 865 2112 for all international customers please contact your local distributor This product should only be installed by someone of good mechanical aptitude has experience with basic building construction and fully understands these instructions Make sure that the supporting surface will safely support the combined load of the equipment and all attached hardware and components Never exceed the Maximum UL Load Capacity See page one If mounting to wood wall studs make sure that mounting screws are anchored into the center of the studs Use of an edge to edge stud finder is highly recommended Always use an assistant or mechanical lifting equipment to safely lift and position equipment Ti
8. rete anchor security driver fastener cap cable clip short cable tie snap caps 10 32 x 1 2 thread forming screw 1 4 20 x 1 2 hex head thread forming screw M4 x 16 mm phillips screw 520 2088 long cable tie 2 590 2168 2 lt 046 4176 046 4179 046 4180 500 1090 590 0320 560 1133 046 4096 046 4137 560 2004 560 2029 520 2627 520 2592 r AC TAAMmMVIADA S BS 2 fe fo BS 1 BS Ee amp Zs Parts may appear slightly different than illustrated 3 of 10 ISSUED 10 01 10 SHEET 095 9354 3 12 13 10 Installation to Wood Stud Wall A WARNING e Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components Tighten wood screws so that wall plate is firmly attached but do not overtighten Overtightening can damage the screws greatly reducing their holding power Never tighten in excess of 80 in Ib 9 N M Make sure that mounting screws are anchored into the center of the stud The use of an edge to edge stud finder is highly recommended Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs Installers are responsible to provide hardware for other types of mounting situations not evaluated by UL Use a stud finder to locate the edges of the studs Use of an edge to edge stud finder is highly recommended D Based on their edges draw a vertic
9. ucing their holding power Never tighten in excess of 80 in Ib 9 N M Always attach concrete anchors directly to load bearing concrete Never attach concrete anchors to concrete covered with plaster drywall or other finishing material If mounting to concrete surfaces covered with a finishing surface is unavoidable not evaluated by UL the finishing surface must be counterbored as shown below Be sure concrete anchors do not pull away from concrete when tightening screws If plaster drywall is thicker than 5 8 16 mm custom fasteners must be supplied by installer not evaluated INCORRECT CUTAWAY VIEW 5 of 10 concrete surface E Tighten all fasteners SOLID CONCRETE CINDER BLOCK ISSUED 10 01 10 SHEET 095 9354 3 12 13 10 e Be sure to carry display upright from the top and bottom edges or damage to display may occur 2 Follow instruction manual included with display to remove display from stand Set display on a flat level surface Refer to display manufacturer s installation guide for recommended careful handling Remove two M4 chrome plated screws from Ultra Slim wall mount bar Save all screws Install eight standoff screws included wit
Download Pdf Manuals
Related Search
Related Contents
Coleman 2300-700 Water Heater User Manual V. Mueller™ CA600(T)(FG)シリーズ 20MHz/30MHz アナログオシロスコープ CALTEK User`s Manual - Firmware Center Raritan Computer 12-898 User's Manual Guía del usuario del mensaje IFTMCS para la comunicación Superflex Eco Bic Phone manual CG-K/CG-KF シ リ ーズ Manuale - Elettronica Nobile S.a.s. Copyright © All rights reserved.