Home

Peavey Electronics Speaker 48 User's Manual

image

Contents

1. 1200 ms Gain 0 Amplifier Level Settings Sensitivity set at 10 dB is recommended when using Peavey CS series amps All channels set to the same voltage gain referenced to the 12 woofer Crest power amps should be used with the sensitivity setting in the x20 position and the attenuators fully clockwise wide open Please review our white paper on minimizing system noise when using VSX on our website VSX presets A VSX 26 may be used to provide a conventional 2 channel stereo three way control of any Versarray System The VSX 48 should be selected when it is desirable to control the system in zones that may be used to split coverage between balconies and a main floor or when shading of EQ or Level is desired The added control provided by the VSX 48 gives the user additional capabilities to fine tune the system The VSX 48 presets also provide an easy means to use an aux fed sub system see our white paper http Awww peavey com support technotes VSX26 presets Input Ato out 1 subs out 2 mids out 3 highs Input Bto out4 subs out 5 mids out 6 highs VSX 48 presets Input Out 1 mids top pair Out 2 highs Out 3 mids middle pair Out 4 highs Out 5 mids bottom pair Out 6 highs Out 7 subs Input B Out 8 subs for aux fed subs
2. woofer level increase relative to a subwoofer level A uniform splay of 5 degrees per cabinet for an 8 cabinet array would require approximately 5 dB of tweeter level boost and approx 1 dB of 12 woofer level increase relative to a subwoofer Complete processor settings for the recommended 2 5 degree continuous curvature with 6 Versarray 112 cabinets and one Versarray 218 Sub Front End EQ before the crossover section PEQ 4 0 dB 2k bw 0 7 or use 1 3 octave band 2 kHz set to 2 5 dB AND 1 3 octave band 1 6 kHz set to 2 dB Infrasonic filtering 24 dB oct LR 34 Hz Crossover settings Woofer 24 dB oct LR 2 0 kHz Tweeter 24 dB oct Bessel 3 0 kHz Woofer Polarity Normal Tweeter Polarity Normal EQ after crossover Woofer EQ PEQ 1 5 dB 560 Hz bw 0 5 PEQ 3 5 dB 850 Hz bw 0 5 PEQ 3dB 115 Hz bw 2 PEQ 1 5 dB 2 2 kHz bw 7 PEQ 2 dB 700 Hz bw 3 0 Woofer Delay 0 0 ms none Tweeter EQ PEQ 3 dB 2 7 kHz bw 0 7 PEQ 2 5 dB 4 6 kHz bw 1 0 PEQ 3 5 dB 16 5 kHz bw 1 0 Tweeter Delay 0 0 ms none Sub to Woofer Crossover Sub 24 dB oct LR 125Hz Woofer 24 dB oct LR 100Hz Sub Polarity Normal Woofer Polarity Normal Sub EQ PEQ 4 0 dB 50 Hz bw 0 7 PEQ 2 5 dB 100 Hz bw 0 5 Level Settings for same model of power amp with all channels set to the same voltage gain One Versarray 218 Sub 4 dB Versarray 112 Woofer 0 0 dB Tweeter 8 5 dB for
3. Setting up the Versarray System Processor Settings for Versarray 112Neo amp Subs with VSX 26 48 also Digitool Prolinx Single VR112 Neo Cabinet w 118 Sub Front End EQ before the crossover section PEQ 2 0 dB 2k bw 0 6 or use 1 3 octave band at 2 kHz set to 2 0 dB Infrasonic filtering 24 dB oct LR 34 Hz Crossover settings Woofer 24 dB oct LR 2 0 kHz Tweeter 24 dB oct Bessel 3 0 kHz Woofer Polarity Normal Tweeter Polarity Normal Sub to Woofer Crossover Sub 24 dB oct LR 125Hz Woofer 24 dB oct LR 100Hz Sub Polarity Normal Woofer Polarity Normal EQ after crossover Woofer EQ PEQ 1 5 dB 560 Hz bw 0 5 PEQ 3 5 dB 850 Hz bw 0 5 PEQ 3dB 115 Hz bw 2 PEQ 1 5 dB 2 2 kHz bw 7 PEQ 2 dB 700 Hz bw 3 0 Woofer Delay 0 0 ms none Tweeter EQ PEQ 3 dB 2 7 kHz bw 0 7 PEQ 2 5 dB 4 6 kHz bw 1 0 PEQ 3 5 dB 16 5 kHz bw 1 0 Tweeter Delay 0 0 ms none Sub EQ PEQ 4 0 dB 50 Hz bw 0 7 PEQ 2 5 dB 100 Hz bw 0 5 Chart for Changes with Number of Cabinets No of Cabs 1 2 3 4 6 8 218 Sub Levelt 6 0 dB 2 5 dB 0 5 dB 1 5 dB 4 dB 5 5 dB 12 Wfr 0 0 dB 0 0 dB 0 0 dB 0 0 dB 0 0 dB 0 0 dB Level Twtr 0 0 dB 2 0 dB 4 0 dB 5 5dB 6 5 dB 7 0 dB Level Drive levels are for factory 16 ohm wiring for 4 ohm wiring subtract 6 dB Front Block EQ at 2 kHz 2 0 dB at1 8kHz 3 0 dB 3 5 dB 3 5 dB 4 0 dB 4 5 dB at a bw
4. ribbons wired 16 ohms SPECIAL NOTE Versarray 218 Sub is in 4 ohm mode woofers paralleled If the Versarray 218 Sub woofers are driven separately using an amp with the same gain as all the other amps then drive level does not increase A word about system low end The above settings will produce a nominally flat system It is currently fashionable for modern systems to have 6 GB to 15 dB boost in output compared to midband If this is desired then simply do not cut the drive to the subs and if necessary turn the attenuator clockwise to wide open If such drastic response is required consider using an Aux Fed Sub arrangement Dynamics settings The following settings have been chosen to provide a reasonable balance between dynamic range and speaker protection You may wish to save an additional preset with safe mode settings by reducing the threshold by 6 dB It is often a good idea to start the system up in the safe mode until it is determined that everything is running correctly and the system operator is capable of safe driving The trade off is more protection for less dynamic range Recommended settings using CS series power amps Amps w att wide open x40 gain Ribbons Threshold 2 dB Attack 5ms 10 ms Release 50ms 100 ms Gain 0 12 woofer Threshold 4dB Attack 50ms 100 ms Release 500ms 1000 ms Gain 0 Subs Threshold 7dB Attack 60ms 150 ms Release 600ms
5. set to 0 577 bw 707 bw 707 t SPECIAL NOTE Versarray 218 Sub is supplied in 4 ohm mode woofers paralleled If the Versarray 218 Sub woofers are driven separately using an amp with the same gain as all the other amps then drive level to the separate woofers is the same To convert the above drive levels for a single Versarray 218 Sub to drive levels suitable for a single Versarray 118 Sub add 6 dB When doubling the number of Subs subtract 6 dB for each time they are doubled SPECIAL NOTE To match this PEQ setting with a 1 3 octave band EQ use the following To equate to a PEQ setting of 3 dB 1 8k bw 0 6 use 1 3 octave band 2 kHz set to 1 5 dB AND 1 3 octave band 1 6 kHz also set to 1 5 dB To equate to a PEQ setting of 3 5 dB 1 8k bw 0 6 use 1 3 octave band 2 kHz set to 2 dB AND 1 3 octave band 1 6 kHz set to 1 5 dB To equate to a PEQ setting of 4 dB 1 8k bw 0 7 or use 1 3 octave band 2 kHz set to 2 0 dB AND 1 3 octave band 1 6 kHz set to 2 0 dB To equate to a PEQ setting of 4 5 dB 1 8k bw 0 7 or use 1 3 octave band 2 kHz set to 2 5 dB AND 1 3 octave band 1 6 kHz set to 2 0 dB Line curvature or splay between cabinets Splaying the line will tend to require more level increase from the tweeters and some more cut EQ at 1 8 kHz A uniform splay of 2 5 degrees between cabinets for an 8 cabinet array would need approximately 2 dB of tweeter boost and 0 5 dB of 12

Download Pdf Manuals

image

Related Search

Related Contents

Exhibitor Service Manual  catalogue - College Tunisie    BMP71 User Guide-Fre.book - Cepelec au service de l'industrie  Bryant FF1DNA User's Manual  取扱説明書(2.0MB)  Avaya VPNremote for 4600 Series IP Phone Admin Guide  3A3118B, Husky 1050HP 2:1 Diaphragm Pumps  Sable dans les cimetières - Mode d`emploi (1,27 MB  

Copyright © All rights reserved.
Failed to retrieve file