1. Manufacturer OMRON HEALTHCARE Co Ltd 53 Kunotsubo Terado cho Kyoto 617 0002 JAPAN EU representative OMRON HEALTHCARE EUROPE B V Scorpius 33 2132 LR Hoofddorp THE NETHERLANDS www omron healthcare com OMRON HEALTHCARE MANUFACTURING VIETNAM CO LTD Binh Duong Province VIETNAM Production facility Planta de producci n Site de production Productiefaciliteit Herstellungswerk Stabilimento di produzione 62 221 Subsidiary Empresa filial Succursale Dochteronderneming Niederlassung Consociata imas OMRON HEALTHCARE UK LTD Opal Drive Fox Milne Milton Keynes MK15 0DG U K OMRON MEDIZINTECHNIK HANDELSGESELLSCHAFT mbH John Deere Str 81a 68163 Mannheim GERMANY www omron medizintechnik de OMRON SANT FRANCE SAS 4 rue de Lisbonne 93561 Rosny sous Bois Cedex FRANCE Uniquement pour le march frangais JOMRON Service Apr s Vente N Vert 0 800 91 43 14 consommateurs 9omron sante fr www omron sante fr contact Made in Vietnam Fabricado en Vietnam Fabriqu en Vietnam Geproduceerd in Vietnam Hergestellt in Vietnam Prodotto in Vietnam mue Check following components V rifier les composants suivants Controleer de volgende onderdelen Pr fen Sie folgende Teile des Lieferumfangs Co
2. gt _ it a Push 4 or I buttons to change T 420 1 Is B 9 2 Push the button confirm a T AE on lt 1 vu N Next setting appears Day Minute ES Press the START button to store the setting Notes If the batteries have been removed for 30 seconds or more the date and time setting will need to be reset If the date and time are not set appears during or after measurement ores Open both the front and rear covers to read following The alphabet and number in the cover page correspond to those in the body page 3 1 Applying the Arm Cuff Remove tight fitting clothing or tight rolled up sleeve from your upper arm Do not place the cuff over thick clothes 1 Insert the air plug into the air jack 2 Put your arm through the cuff loop 3 Position the arm correctly The bottom edge of the cuff should be a 1 to 2 cm above the elbow D Marker arrow_ under tube is centred on the middle of your inner arm Close the fabric fastener FIRMLY Notes e When you take a measurement on the right arm air tube will be at the side of your elbow Be careful not to rest your arm on the air tube e The blood pressure can differ between the right arm and the left arm and therefore also the measured blood pressure values can be different OMRON recommends to always use the same arm for measurement If the values betwe
3. Battery compartment DAC adapter jack for optional AC adapter Arm cuff DArm cuff Wide Range Cuff arm circumference 22 42cm Marker Air tube DAir plug Display Systolic blood pressure N Diastolic blood pressure Heartbeat symbol Flashes during measurement Average value symbol Q Deflation symbol Memory symbol S Irregular heartbeat symbol Movement error symbol 0 Blood pressure level indicator V Pulse display and Memory number W Buzzer symbol x Cuff wrapping guide G USER ID symbol Battery low symbol Date Time display 2 Preparation 2 1 Installing Replacing the Batteries 1 Remove the battery cover 2 Insert four AA batteries as indicated in the battery compartment and then replace the battery cover Notes If the battery low symbol 4X appears on the display turn the unit off then replace all batteries at the same time The measurement values continue to be stored in memory even after the batteries are replaced Disposal of used batteries should be carried out in accordance with the national regulations for the disposal of batteries 2 Preparation 2 2 Setting the Buzzer Date and Time 1 Press the button 2 Set the Buzzer GIL 1 Push lt buttons to select On or Off C 2 Push the button to confirm 3 Set the monitor to the correct date and time before pr a measurement for the TS time S A lt
4. For professional office blood pressure measurement criteria please refer to Chapter 7 10 3 Using the Unit Your blood pressure monitor includes an irregular heartbeat feature Irregular heartbeats can influence the results of the measurement The irregular heartbeat algorithm automatically determines if the measurement is usable or needs to be repeated If the measurement results are affected by irregular heartbeats but the result is valid the result is shown together with the irregular heartbeat symbol If the irregular heartbeats cause the measurement to be invalid no result is shown If the irregular heartbeat symbol is shown after you have taken a measurement repeat the measurement If the irregular heartbeat symbol is shown frequently please make your doctor aware of it If you move during measurement the movement error symbol ffi will appear on the display Keep still and repeat the measurement 11 3 Using the Unit 3 4 Using the Memory Function The monitor automatically stores the result up to 60 sets for each user A and B It can also calculate an average reading based on the measurements from the last three readings taken within 10 minutes If there are only two readings in memory for that period the average will be based on two readings If there is one reading in memory for that period the average will be based on one reading Notes If the memory is full the monitor will delete th
5. O I START button again The cuff will start to inflate automatically The buzzer will sound when measurement is completed 3 Using the Unit If your systolic pressure is more than 220 mmHg After the cuff starts to inflate press and hold the O I START button until the monitor inflates 30 to 40 mmHg higher than your expected systolic pressure WSTART WINFLATE W COMPLETE WEND WDEFLATE Notes The monitor will not inflate above 299 mmHg Do not apply more pressure than necessary Notes e During measurement the buzzer if set to on will beep in rhythm with your heartbeat Wait 2 3 minutes before taking another blood pressure measurement Waiting between readings allows the arteries to return to the condition prior to taking the blood pressure measurement A Warning Self diagnosis of measured results and treatment are dangerous Please follow the instructions of your doctor 3 Using the Unit 4 Remove the arm cuff 5 Press the O I START button to turn off the monitor The monitor automatically stores the measurement in its memory It will automatically turn off after five minutes Important Recent research suggests that the following values can be used as a guide to high blood pressure for measurements taken at home Systolic Blood Pressure Above 135 mmHg Diastolic Blood Pressure Above 85 mmHg This criteria is for home blood pressure measurement
6. cuff not applied correctly Movement or talking during measurement Clothing is interfering with the arm cuff The air tube is not securely connected into the main unit Air is leaking from the arm cuff The arm cuff is loose The arm cuff has not been inflated sufficiently Apply the arm cuff correctly Refer to section 3 1 Remain still and do not talk during measurement Refer to section 3 3 Remove any clothing interfering with the arm cuff Refer to section 3 2 Make sure that the air tube is connected securely Refer to section 3 1 Replace the arm cuff with a new one Refer to Chapter 5 Apply the cuff correctly so that it is firmly wrapped around the arm Refer to section 3 1 Inflate the cuff so that it is 30 to 40 mmHg above your previous measurement result Refer to section 3 3
7. e oldest readings e When viewing the reading taken without setting the date and time is displayed instead of the date and time To View the Average Value 1 Press the 4 or gt button 2 Select your USER ID A or B Note If there are no measurements results stored in the memory the screen to the right is displayed 12 3 Using the Unit To View the Readings Stored in Memory 1 Press the button while the average value is displayed The Memory number appears for a second Alternating date before the pulse rate is displayed The newest time display set is numbered 1 2 Press the 4 or gt button to view the readings stored in memory To the older readings gt To the more recent readings To Delete All the Values Stored in Memory The values stored in the memory are deleted by USER ID When the memory symbol E appears first press the button Then while holding it down press the O I START button simultaneously for about 2 3 seconds Note You cannot partially delete values stored in the memory START All values for the user you select will be deleted 4 Troubleshooting and Maintenance 4 1 The Icons and Error Messages Remove the arm cuff Wait 2 3 minutes and then take another measurement Repeat the steps in section 3 3 If this error continues to appear contact your doctor Irregular or weak pulses are detected Movement during
8. en the two arms differ substantially please check with your physician which arm to use for your measurement 3 Using the Unit 3 2 How to Sit Correctly To take a measurement you need to be relaxed and comfortably seated under comfortable room temperature No eating smoking or exercising 30 minutes before taking a measurement e Sit on a chair with your feet flat on the floor Sit upright with your back straight c The cuff should be at the same level as your heart d Cuff wrapping guide EN The Cuff Wrapping Guide is a unique feature that indicates if the cuff is not wrapped tightly enough around the arm Even when the 5 is displayed a blood pressure reading will be taken Note This reading is NOT reliable due to the incorrect wrapping of the cuff Please wrap the cuff again taking care to wrap it correctly and take the measurement again When the D is displayed the cuff is correctly wrapped tightly enough on the arm and the reading is accurate and reliable 3 Using the Unit 3 3 Taking a Reading Notes To cancel a measurement press the O I START button to turn off the unit and to release the air in the arm cuff Remain still while taking a measurement The monitor is designed to take measurements and store the measurement values in the memory for two people using USER ID A and USER ID B 1 Press the O I START button 2 Select your USER ID A or B USER A B O 3 Press the
9. measurement Carefully read and repeat the steps in section 3 3 Cuff is not applied correctly Apply the arm cuff correctly Refer to section 3 1 You should replace them with new ones ahead of Blink The batteries low time Refer to section 2 1 me batteries are exhausted You should replace them with new ones at once Refer to section 2 1 14 4 Troubleshooting and Maintenance Carefully read and repeat the steps listed under Cuff is under inflated section 3 3 Repeat measurement Remain still and do not Movement during measurement talk during measurement Refer to section 3 3 Insert the air plug securely elsconne clon Refer to section 3 1 Apply the arm cuff correctly Arm cuff not applied correctly Refer to section SA Clothing is interfering with the arm cuff Remove any clothing interfering with the arm cuff Refer to section 3 1 ES Replace cuff with new one Air is leaking from the arm cuff Refer to Chapter 5 The arm cuff was inflated above 299 Do not inflate the arm cuff above 299 mmHg mmHg when inflating the cuff manually Refer to section 3 3 Note The irregular heartbeat symbol may also be displayed with error messages 15 16 4 Troubleshooting and Maintenance 4 2 Troubleshooting The reading is extremely low or high Arm cuff pressure does not rise Arm cuff deflates too soon Cannot measure or readings are too low or too high Arm
10. ntrollare i componenti indicati di seguito Xd cusa o gias iCompruebe los siguientes componentes Digital Automatic Blood Pressure Monitor Model M3W Instruction Manual GD Intelli SV sense for Healthcare IM HEM 7202 E V 02 01 2012 5334060 6B Thank you for purchasing the OMRON M3W Digital Automatic Blood Pressure Monitor The OMRON M3W is a compact fully automatic blood pressure monitor operating on the oscillometric principle It measures your blood pressure and pulse rate simply and quickly For comfortable controlled inflation without the need of pressure pre setting or re inflation the devices uses its advanced IntelliSense technology Intended Use This product is designed to measure the blood pressure and pulse rate of people within the range of the designated arm cuff following the instructions in this instruction manual It is mainly designed for general household use Please read the Important Safety Information in this instruction manual before using the unit Important Safety Inform 1 Overview 2 Preparation 2 1 Installing Replacing the Batteries 2 2 Setting the Buzzer Date and Time 3 Using the Unit 3 1 Applying Arm Cuff 3 2 Howto Sit Correctly 3 8 Taking a Reading 34 Using the Memory Function 4 Troubleshooting and Maintenance 4 1 The Icons and Error Messages 42 Troubleshootin 43 Maintenance 44 Storage Optional Par
11. our AA alkaline or manganese batteries with this unit Do not use other types of batteries Do not insert the batteries with their polarities incorrectly aligned Replace old batteries with new ones immediately Replace all four batteries at the same time e Remove the batteries if the unit will not be used for three months or more Do not use new and used batteries together General Precautions Do not apply strong shocks and vibrations to or drop the unit and arm cuff Do not take measurements after bathing drinking alcohol smoking exercising or eating Do not forcibly bend the arm cuff or bend the air tube excessively When removing the air tube pull on the air plug at the connection with the main unit not the tube itself Do not inflate the arm cuff when it is not wrapped around your arm Do not wash the arm cuff or immerse it in water Read and follow the Important information regarding Electro Magnetic Compatibility EMC in the Technical Data Section Read and follow the Correct Disposal of This Product in the Technical Data Section when disposing of the device and any used accessories or optional parts 7 the rear cover page to read following The alphabet in the rear cover page correspond to those in the body page Main unit Display START button OUser A B button Up Down 4 buttons Buzzer and Date Time setting button Air Jack
12. s their consent Do not use the unit for any purpose other than measuring blood pressure Do not disassemble the unit or arm cuff Use only the approved arm cuff for this unit Use of other arm cuffs may result in incorrect measurement results Make sure that the air tube is not wrapped around other parts of your body when taking measurements This could result in injury when the air pressure in the air tube is increased Do not leave the cuff wrapped on the arm if taking measurements during the night This could result in injury Do not inflate the arm cuff over 299 mmHg Do not use a mobile phone or other devices that emit electromagnetic fields near the unit This may result in incorrect operation of the unit Do not operate the unit in a moving vehicle car airplane To inflate the cuff manually refer to Section 3 3 If the cuff is over inflated it can cause internal bleeding Important Safety Information AC Adapter Usage Use only the original AC adapter optional designed for this unit Use of unsupported adapters may damage and or may be hazardous to the unit Plug the AC adapter into the appropriate voltage outlet Do not use a multiple tap Do not use the AC adapter if the unit or the power cord is damaged Turn off the power and unplug the power cord immediately Battery Usage If battery fluid should get on your skin or clothing immediately rinse with plenty of clean water Use only f
13. ts Technical Data Some Useful Information about gt Noa Please read this instruction manual thoroughly before using the unit Please keep for future reference For specific information about your own blood pressure CONSULT YOUR DOCTOR Important Safety Information Consult your doctor prior to using in pregnancy or if diagnosed with arrhythmia or arteriosclerosis Please read this section carefully before using the unit A Warning e Indicates a potentially hazardous situation which if not avoided could result in death or serious injury General Usage e Always consult your doctor Self diagnosis of measurement results and self treatment are dangerous e People with severe blood flow problems or blood disorders should consult a doctor before using the unit as cuff inflation can cause internal bleeding AC Adapter Usage e Never plug in or unplug the power cord from the electric outlet with wet hands EN Battery Usage If battery fluid should get in your eyes immediately rinse with plenty of clean water Consult a doctor immediately AA Caution Indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury to the user or patient or damage to the equipment or other property General Usage Do not leave the unit unattended with infants or persons who cannot expres
Download Pdf Manuals
Related Search
Related Contents
BEDIENUNGSANLEITUNG DOSIERGERÄT 8035 Manuel d`utilisation CEE - Mathieu BERGEROT - Conseil Manual PDF Datei / File ( 4,9 MB) - Dissertation User Manual Wireless G Notebook Card Carte G sans fil pour ordinateur maintenance - Cleanco Truckmounted Fulton Armory Catalog - AR-15 Copyright © All rights reserved.