1. CXP o Nebuliser NUE gt Nebuliser kit JetAIRPIUS see also on page 4 Air tube Air filter compartment air inlet Air outlet connection Power OFF ON switch O I Compressor unit Air ventilation holes Description of the nebuliser kit JetAIRP us 8 14 15 8 Valve cap 9 Exhalation valve 10 Mouthpiece 11 Inhalation valve 12 Nebuliser cap 13 Vaporiser head 14 Jet nozzle inside medication tank 15 Medication tank Inhaling with the OMRON CompAIR CXP Nebuliser Before using the nebuliser the nebuliser kit must be cleaned according to the cleaning and disinfection instruction within this manual see page 7 1 2 Make sure that the filter compartment air inlet and air ventilation holes are not covered otherwise the unit may become overheated Make sure that the power switch is set to the OFF O position and plug in the mains cable For steps 3 7 refer to the drawing below 3 Remove the nebuliser cap from the medication tank by turning it counterclockwise and lifting it Remove the mouthpiece Remove the vaporiser head Fill the medication tank with the prescribed amount and type of medication max 6 ml Reinsert the vaporisation head Reconnect the nebuliser cap to the medication tank and fit the mouthpiece 8 Connect the airtube one end to the compressor unit and the other end to the bottom of the medication tank 10 Although the design of thi
2. d easy handling Before using the nebuliser for the first time please read through this manual carefully If you still have any questions regarding its use please contact OMRON Customer service at the address shown on the packaging or in the enclosed instruction manual They will be pleased to assist you OMRON Healthcare Europe General Information The OMRON CompAIR CXP is a nebuliser for the inhalation of medical aerosols to treat asthma chronic bronchitis and other respiratory tract disorders This nebuliser is suitable for all commonly used inhalation solutions Use only the type and amount of medication prescribed by your doctor The advanced nebulisation system of the OMRON CompAIR CXP 0 produces a very low particle size distri bution and therefore a medication vapour that will reach effectively and reliably the upper and lower respirato ry passages Due to the inhalation and exhalation valves the amount of medication deposited into the lungs is maximized and medication waste is minimized The OMRON CompAIR CXP is suitable for inhalation at home in the hospital or at a doctor s practice Safety precautions Please read the following safety precautions carefully as they contain important information concerning safe Set up use and maintenance of your nebuliser e Keep this manual for future reference e As soon as you have unpacked the nebuliser check it for visible damages or defects In particular check for cracks i
3. d once daily with a clean damp piece of cloth Do not use any volatile fluids Never submerge the compressor unit in water If there is some moisture in the air tube connect the air tube to the compressor unit and leave the other end open Then switch on the compressor unit and blow the tube dry Storage and maintenance e Put the nebuliser kit masks and airtube in a clean bag and place them in the storage pocket of the car rying case e Wrap the mains cable and place it in its storage compartment at the rear of the compressor unit e Do not store the compressor on the floor e The unit does not contain any user serviceable parts and does not require oil Do not attempt to lubricate any internal parts Do not open the compressor unit e Incase you encounter difficulties with your nebuliser please contact your local OMRON dealer address on inside package e Disposal of this product should be carried out in accordance with the national regulations for the disposal of electronic products Filter Check once a month whether the filter in the filter compartment is still white and clean If it turns dirty replace it However this filter should be replaced at least once a year Procedure for replacing 1 Slide the filter cover open to expose the filter compartment 2 Remove the dirty filter with a small pointed object 3 Replace with a clean OMRON filter order no 8403 A set of 5 spare filters is provided with the nebulis
4. er 4 Slide the filter cover closed Caution Do not use cotton or any other material to replace the filter Do not wash or clean the filter Use only OMRON filters Do not operate without a filter Possible problems and how to solve them If the OMRON CompAIR CXP does not nebulise or only very weakly check the following points e Make sure that the power supply plug is firmly fitted onto the wall socket e Make sure that the ends of the air tube are fitted tightly onto the compressor unit and onto the medication tank e Check whether the medication tank is empty If so and if necessary refill the medication tank e Is the vaporiser head installed correctly in the medication tank If not install it and press it down into the jet nozzle e Check whether the air tube is twisted If so untwist e Check whether the jet nozzle is blocked If so unblock it by cleaning the medication tank If not possible to unblock replace the nebuliser kit e Check whether the air filter is clean If not replace it refer to section Filter in this manual Optional accessories parts Nebuliserkit JetAIRPIUS incl airtube mouthpiece inhalation exhalationvalves order no A040001 Inhalation valve for JetAIRPlus order no P040017 Exhalation valve for JetAIRPlus order no P040018 Vaporiser head for JetAIRPIUS order no P040026 Airtube for JetAIRPIUS order no P040019 Flexible adult mask MAF order no A040002 Flexible child mask MPF o
5. n the plastic housing which could expose electrical components If this is the case or if you are in doubt contact your OMRON dealer directly e Only use the nebuliser for its intended purpose for inhalation therapy Any other form of use constitutes an improper use and is therefore dangerous The manufacturer cannot be held liable for any damage caused by improper or incorrect use e Do not leave the unit unattended with people who require supervision e g people with infirmities or children e The unit does not contain any user serviceable parts and does not require oil Do not attempt to lubricate any internal parts Never open the unit e Make sure that the electrical rating shown on the rating label on the bottom of the unit corresponds to your mains voltage and frequency before plugging in the nebuliser e Always disconnect the nebuliser from the mains supply before you start cleaning it e The unit is not protected against water penetration so Never touch the unit when your hands are wet or moist Do not use the nebuliser while you are in the bath or having a shower Never submerge the nebuliser in water In case this occurs accidentally always first disconnect the power supply plug from the wall socket before reaching for the unit After having removed the unit from the water do not use it again Contact your OMRON dealer and have your unit checked e Always switch the unit off first before you disconnect the power plug e Do not
6. omnon com ATR GATS Compressor Nebuliser Kompressor Inhalationsger t Compressor vernevelaar N buliseur compresseur Nebulizzatore a compressore Nebulisador por compresor Instruction Manual English Page 1 10 Gebrauchsanweisung Deutsch Seite 11 20 Gebruiksaanwijzing Nederlands Pagina 21 30 Manuel d instuctions Francais Page 31 40 Manuale di instuzioni Italiano Pagina 41 50 Manual de instucciones Espa ol P gina 51 60 OMRON CompAIR CXPro Nebuliser Table of Contents General information 22 1 ge Fan er uer xc vr T r eS E Safety precautions Description of OMRONCXP Nebuliser Description of JetAIRPIUS Nebuliser kit Inhaling with the OMRON CXP Nebuliser Cleaning and disinfection Storage and maintenance gl RP Possible problems and how to solve them Optional accessories parts Technical data siss ige rene mmn n mener ER SN D JJ O1 I ONN Dear Customer Thank you for purchasing this OMRON product You can be sure that you have made a wise choice By buying the OMRON CompAIR CXP Nebuliser you have chosen a high quality innovative instrument During its development particular attention was given to reliability convenient an
7. rder no A040003 Airfilter set 5 pcs order no 8403 8 Technical data This device fulfills the provisions of the EC directive 93 42 EEC Medical Device Directive and the European Standard EN13544 1 2001 Respiratory therapy equipment Part1 Nebulizing systems and their components Type Dimensions Weight Nebulisation rate Particle size MMAD OUTPUT OUTPUT RATE Max A weighted sound pressure level Minimum recommended fill volume Max air pressure Capacity of medication tank Sound noise level at 1 m distance Operating conditions Storage conditions Supply voltage Power consumption Electrical safety Contents of the package value measured with 0 996 NaCl solution OMRON CompAIR CXP NE C18 160 W x 90 H x 220 D mm approx 2 kg 0 3 ml min average 3 8 um also refer to particle size distribution curve 0 35 ml 0 06 ml min 57 dB 2 ml 2 5 bar 250 kPa 6 ml 60 dB Temperature 10 C 40 C Humidity 10 95 RH Temperature 25 C 70 C Humidity 10 95 RH AC 230 V 50 Hz 85 W Fuse T2 5AL250V UR Rit Class 2 Type B Compressor unit nebuliser kit JetAIRPIUS air tube flexible child mask flexible adult mask carrying case 5 spare filters instruction manual guarantee card Please note that specifications may vary with medication type used MMAD Mean Mass Aerosol Diameter CXP particle size distribution curve Cumulative Vi
8. ron healthcare com OMRON HEALTHCARE UK LTD Omron subsidiary Opal Drive Fox Milne Milton Keynes MK 15 ODG United Kingdom Omron OMRON Medizintechnik Handelsgesellschaft m b H Niederlassung Windeckstr 81a 58163 Mannheim Germany www omron medizintechnik de OMRON SANTE FRANCE SAS 14 rue de Lisbonne 93561 Rosny sous Bois Cedex France 10 OMRON HEALTHCARE EUROPE B V IM NE C18 E 02 07 07
9. s nebuliser kit enables its use in a tilted position sit as upright as possible during the inhalation If you must be treated in bed support yourself with pillows Always be calm and relaxed when you inhale Breathe in slowly and deeply so that the medication can reach deep into the bronchial tubes Hold your breath for a short time Then breathe out slowly It is not necessary to remove the mouthpiece from your mouth the inhalation and exhalation valves are automatically controlled by your breathing During inhalation air will enter the nebuliser through the inha lation valve During your exhalation exhaled air will leave the nebuliser through the exhalation valve Do not try to breathe too quickly Pause when you feel like having a rest Breathe in Breathe out 11 When the treatment is finished set the OFF ON switch O I to the OFF O position and disconnect the power plug from the wall socket 12 Clean the nebuliser kit refer to the cleaning instructions on page 7 Note If a mask is used remove the mouthpiece from the nebuliser cap and connect the mask instead Place it with the rubber band onto the face so that the mask will enclose the nose and the mouth The tightness of the rubber band can be adjusted The mask has openings which will enable unres trained breathing Cleaning and disinfection Disinfect the nebuliser before first use and at least once per day when in use Procedure Disassemble the nebuliser kit b
10. sit us at www omron healthcare com Undersize 100 50 Concentration Alog Dp Dp um Subject to technical modification without prior notice Symbols la Class Il A Type B O I power switch OFF ON bg Warning read the instruction manual carefully C 0197 Important information regarding Electro Magnetic Compatibility EMC With the increased number of electronic devices such as PC s and mobile cellular telephones medical devices in use may be susceptible to electromagnetic interference from other devices Electromagnetic interference may result in incorrect ope ration of the medical device and create a potentially unsafe situation Medical devices should also not interfere with other devices In order to regulate the requirements for EMC Electro Magnetic Compatibility with the aim to prevent unsafe product situ ations the IEC60601 1 2 standard has been implemented This standard defines the levels of immunity to electromagnetic interferences as well as maximum levels of electromagnetic emissions for medical devices This medical device manufactured by OMRON Healthcare conforms to this IEC60601 1 2 2001 standard for both immunity and emissions Nevertheless special precautions need to be observed o Do not use mobile cellular telephones and other devices which generate strong electrical or electromagnetic fields near
11. the medical device This may result in incorrect operation of the unit and create a potentially unsafe situation Recommendation is to keep a minimum distance of 7 m Verify correct operation of the device in case the distance is shor ter Further documentation in accordance with IEC60601 1 2 2001 is available at OMRON Healthcare Europe at the address mentioned in this instruction manual Documentation is also available at www omron healthcare com Correct Disposal of This Product Waste Electrical amp Electronic Equipment This marking shown on the product or its literature indicates that it should not be disposed of with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for disposal This product does not contain any hazardous substances OMRON HEALTHCARE EUROPE B V Kruisweg 577 2132 NA Hoofddorp The Netherlands wwiw om
12. use the unit in the presence of anaeststhetic mixtures which are inflammable when they come into contact with air oxygen or nitrous oxide e Keep the power cable away from heated or hot surfaces e If you discover that the nebuliser or its mains cable is damaged or does not operate properly switch it off immediately disconnect the power plug and stop using it Contact your OMRON dealer and have your unit checked e Always use original OMRON nebuliser kit and air filter order no for replacements can be found in this manual e Do not block the air ventilation holes on left right side of the compressor unit e Place the compressor unit on a flat and stable surface during operation e Although this device fulfils the provisions of the EMC Electromagnetic Compatibility directive the use of it should be avoided in direct vicinity of other electric devices e This device is not suitable for use in anaestetic breathing systems e Before using this device be sure to confirm proper operation of the device Prepare and fill the nebuliser kit as instructed in the manual followed by visual checking if aerosol comes out after power on of the device e Specifications regarding Output Output rate and particle size may depend on the type of medication used Especially suspensions and high viscosity medications may have big influence on the indicated specifications See drug supplier s data sheet for further details Description of the OMRON CompAIR
13. y disconnecting the air tube and mouthpiece or mask Remove the nebuliser cap from the medication tank and remove the vaporizer head Also refer to the illustrations as shown under step 3 and 4 page 5 Disinfect all disassembled nebuliser parts NOT the air tube and masks by placing them in boiling water max 10 minutes or in an autoclave max 121 C refer to the autoclave instructions for the duration To clean the nebuliser and mask immediately after each treatment it is sufficient to rinse the disassembled parts under running warm tap water The masks can be disinfected by any commercially available disinfectant containing hypochloride After cleaning disinfecting of the parts place them on a clean paper towel and let them air dry For hygienic reasons each person should use their own nebuliser kit It is recommended that the nebuliser kit is replaced every 6 months or earlier in case the nebuliser is obstructed in order to maintain efficient inhalation Contact your OMRON dealer for replacements The exterior of both the air tube and compressor unit should be cleaned once daily with a clean damp piece of cloth Do not use any volatile fluids Never submerge the compressor unit in water If there is some moisture in the air tube connect the air tube to the compressor unit and leave the other end open Then switch on the compressor unit and blow the tube dry The exterior of both the air tube and compressor unit should be cleane