Home
Omron Healthcare HEM-637 User's Manual
Contents
1. Deletes all the measurement values stored in this monitor Do not delete them in a normal situation e Please note deleted measured values cannot be restored Push the SET button while the power is turned off DELETE DATA NC ES NO Keep pressing the button until Delete Data Screen ad is displayed ne All Memory Erasure Screen Select YES or NO o S DELETE DATA The initial setting of the monitor is NO at any time t VES Ho 1 For selecting YES All Memory Push the 4 button to set to YES Erasure YES Screen If you push the SET button a screen asking ARE ARE YOU SURE YOU SURE is displayed for reconfirmation 2 ves HO Push the gt button again to set to YES To cancel push the button to NO Are You Sure YES Screen If you select YES in Are You Sure Screen following Delete Data Screen and push the SET button the display changes to Data Deleted Blank Screen All the data in memory is deleted and then the power will be turned off If you select NO and push the SET button the data in memory are not deleted and the display changes p Data Deleted to Reset Settings Screen Blank Screen 23 How to Use the Graph Function This monitor has a function to display the stored measurement results as a graph If you measure your blood pressure in a certain time frame for three times a day in the morning daytime and evening you will learn the trending of your blood pressure
2. Do not use batteries not specified for this unit worn and new batteries together or different brands of batteries together Automatic Memory Setting The monitor stores the measured values and the date and time of measurement which is helpful for the continuous blood pressure management However if more than one person is expected to use this monitor the measured values of more than one person will be stored In that case setting the Automatic Memory to OFF is recommended 1 Push the SET button while the power is turned off UTO HEHORY ERSE FY Automatic Memory Screen is displayed Kran are 1 Automatic Memory Screen 2 Select ON or OFF e The monitor is set to ON to store at time of your purchase AUTO HEHORY To set it to OFF push the button on DFF aK e If you want to set to ON after setting it to OFF push the button s Automatic Memory OFF Screen 3 Lock the setting If you are going to change other settings push the SET button to lock the setting e When you push the SET button the display changes to the Position Sensor Screen If you want to finish operation after locking the setting push the START STOP button to turn off the power Advanced Positioning Sensor APS Setting Set the APS function to ON or OFF and set SIGNAL of the position sensor to ON beeps or OFF does not beep 1 Push the SET button while the power is turned off
3. TIME SET P97 Time Screen Please be careful not to raise your wrist too high If your wrist is raised higher than the level of your heart the monitor will let it know with the display of a 4 mark Slowly lower your wrist so that the 4 mark aligns with the level of your heart mark using your elbow as the axis od gt oq l LEFT WRIST LEFT WRIST LEF ARIST When the wrist reaches the proper position the monitor beeps and automatically starts inflation and measurement 19 How to Measure Blood Pressure continued When the wrist reaches the level of your heart the monitor beeps and the Y mark changes to the mark instantly Hold your wrist at that position and do not make any movements until the measurement results are displayed e Be careful not to raise your wrist too high o bm ro om i LEFT WRIST LEFT WRIST LEFT WRIST e chat Mark Inflation Start Screen Indicating Inflation in v Progress 1725 AM When your wrist reaches the Pulse wee proper position the monitor beeps rien m iis 58 and automatically starts inflation Mar e ferr and measurement E Inflation in Progress Screen E118 3 When the measurement finishes the deflation ee i i 4 Fpppta mark flashes and the wrist cuff deflates Deflation 70 The measurement Its blood Mark ae e ent results 9100C pressure A Start Screen values pul
4. gt button Push gt to move the displayed item forward Push 4 to move the displayed item backward In the Selection Screen push SET button either button for selection Push this button to set various items on the monitor such as time setting Know Your Unit MEMORY button Push this button to see the measured values stored in the monitor GRAPH button Push this button to see the graph START STOP button Push this button to measure blood pressure You can also push this button to stop measurement or turn off the power Push this button in the Setting Screen to lock the setting Suggestions Before Measuring Blood Pressure 1 Avoid eating smoking and exercising for at least 30 minutes before taking measurement Also rest for at least 10 to 15 minutes before taking a reading 2 Stress raises blood pressure Avoid taking measurements during stressful times 3 The cuff can be applied to your left or right wrist 4 Measurements should be taken in a quiet place and you should be in a relaxed seated position 5 Remain still and do not talk during the measurements 6 Keep a record of you blood pressure and pulse for you doctor Remember a single measurement does not provide an accurate indication of your true blood pressure You need to take and record several readings over a period of time Try to measure your blood pressure at the same time each day for consistency 7 Wait 2 3 minutes betw
5. values and pulse rate in a week at a glance One of the measurement results in each time frame of morning daytime and evening is displayed in the graph Morning data The last measurement made between 12 A M and 9 59 A M Daytime data The last measurement made between 10 A M and 5 59 P M Evening data The last measurement made between 6 P M and 11 59 P M If you measure three times in the morning time zone only the third measurement values are displayed in the graph If no measured value exists in a time frame a blank column is displayed There are three types of graphical displays All data graph Displays all the data for morning daytime and evening in a week Morning data graph Displays the morning data in a week Evening data graph Displays the evening data in a week No graph display is provided for showing only daytime data To display the graph 1 Push the GRAPH CALL button 131 170 All Data Graph is displayed PM ll p play aa il il lls iF a All Data Graph Push the GRAPH CALL button again pial e l 170 to display the Morning Data Graph l aba 110 Morning Data Mark el Oa Morning 24 Data Graph How to Use the Graph Function continued Push the GRAPH button again to display the Evening Data Graph Each time you push the GRAPH button All Morning and Evening data are displayed in that order repeatedly Night Data Graph 2 Push the START STOP but
6. ET Push the SET button to lock the Hour gt AM E J0 e Minute will flash PM 8 00 Push the button to set the Minute to 30 Push the SET button to lock the Minute ALARH SET Each time you push the 4 button the display AH 6330 changes in the regressive order such as 59 PH 8 008 and 58 If you keep pressing the button Minute will ALARH SET change fast forward AH 6 354 gt The A mark flashes PH 8 00 Push either 4 or to change from not to go off to amp to go off then push the SET button to lock the setting 12 Ala rm Setting Continued e Once the first alarm time is locked the second ALARM SET alarm time of Hour and PM 8 flashes 7 AM 6 304 In the same manner set the hour for the second Aner time and to go off gt PH 8400 ALARM SET AH 6 304 PH 8 0 8 AN y Screen of setting the alarm to 3 Lock the setting go off at 6 30 A M and 8 P M If you are also going to change other settings push the SET button to lock the setting l ALARM e When you push the SET button the display changes to the Time Screen Screen of indicating that If you want to finish by locking the setting push the alarm is sounding the START STOP button to turn off the power 13 Date and Time Setting Setting the date and time is recommended before use of the monitor for continuous blood pressure management This blood pressure monitor automatically stores 90 measureme
7. Keep pressing the SET button until the SA pages Position Sensor Screen is displayed 1 gt srewat ON OFF 2 Select ON or OFF Position Sensor Screen e The Position Sensor is set to ON and the SIGNAL is set to ON to beep at the time of your purchase of the monitor For setting the Position Sensor to OFF ae a an Push the gt button to set the Position Sensor to OFF Position Sensor OFF Screen e To set it to ON after setting it OFF push the button POSITION SENSOR ON OFF SIGNAL There is no SIGNAL setting when Shon OFF the Position Sensor is set to OFF Position Sensor ON and SIGNAL ON Screen How to set the SIGNAL to OFF when aeons the Position Sensor is set to ON SIGNAL AT ON gt 3FF ziS Push the SET button to make SIGNAL ON flash Position Sensor ON and i SIGNAL OFF Screen To set the monitor to SIGNAL OFF push the button 3 Lock the setting If you are also going to change other settings push the SET button to lock the setting When you push the SET button the display changes to Measurement Screen If you want to finish after locking the setting push the START STOP button to turn off the power 10 Wrist Selection Setting Measurement can be made on the left wrist or on the right wrist Push the SET button while the power PRIEST is turned off p Keep pressing the button until the Measurement Screen is displayed Measuring Wrist Scre
8. abrasive or volatile cleaners Do not attempt to clean the wrist cuff e Never immerse the monitor or any components in water e Store the monitor in a safe and dry location Do not subject the monitor to extreme hot or cold temperatures humidity and direct sunlight e Avoid subjecting the monitor to strong shocks such as dropping on the floor e Remove the batteries if the unit will not be used for an extended period of time e Use the unit consistent with the instruction provided in this manual e Never inflate the unit over 299mmHg or attempt to disassemble the monitor Use only authorized parts and accessories 27 FCC Caution Caution Changes or modifications not expressly approved by Omron Healthcare Inc could void the user s authority to operate this product Note POTENTIAL FOR RADIO TELEVISION INTERFERENCE for U S A only This product has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation The product generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If the product does cause harmful interference to radio or televisio
9. creen the time is set to 00 seconds and matches ot Minnie 39 with the time tone TINE SET 2002 1 25 AH 8 D 3 Minute is indicated by flashing display of 00 Screen of 8 A o on January 25 2002 9 Lock the setting Push the SET button 15 How to Reset This Monitor Reset Settings Any change made in the Setting Mode is cancelled to restore the state at the time of your purchase of the monitor After initialization be sure to set the date and time e The stored measurement values are not deleted If you want to delete them execute All Memory Erasure 1 Push the SET button while the power is turned off Keep pressing the button until the Reset ea are Settings Screen is displayed veS gt Qo 2 Select YES or NO Reset Settings Screen e The initial setting of the monitor is NO at any time For selecting YES RESET SETTINGS Push the 4 button and select YES gt rt a 8 If you push the SET button a screen asking Are You Sure is displayed for reconfirmation Reset Settings YES Screen To set to YES push the 4 button again ARE You SURE To cancel push the button P If you select YES and push the SET button all settings are resumed to the state at the time of Are You Sure YES Screen your purchase and the display changes to the Automatic Memory Screen AUTO HEHORY THEN DFF If you select NO and push the SET button i the display changes to Automatic Memory Scree
10. e measurement may be impossible e Those having a slender wrist wrist circumference of less than 5 4 inches may feel the wrist cuff move if the velcro is not wrapped snugly In that case do not wrap the wrist cuff any tighter it will not affect the measurement Fold and fasten the extra portion of wrist cuff as shown to the right Even if the extra portion of wrist cuff is not fastened it will not affect the measurement T hies E You can also measure your blood pressure on your right wrist Wrap the wrist cuff as shown in the Figure to the right Oem e Change the Measurement to Right Hand in the Setting Mode 18 This measurement example describes the situation where the Position Sensor is set to ON and the How to Measure Blood Pressure SIGNAL is set to ON 1 Push the START STOP button The Position Sensor Screen is displayed If the date and time is not set the Time Screen is displayed Be sure to set the date and time before using this monitor Hold your elbow firmly to avoid body movement Remain still and do not talk during measurement Adjust the height of your wrist by using your elbow as the axis so that the mark can be aligned with the mark The wrist movement is indicated with the mark Slowly move your wrist up and down so that the wrist comes to the level of your heart mark POSITION ddad LEFT WRIST AD au gt LEFT WRIST
11. een measurements Waiting allows the engorged blood vessels to return to normal You may require more rest time between readings depending on your individual physiological characteristics Battery Installation Use this monitor after inserting batteries in the main unit 1 Place the main unit with the Battery Cover facing upward 2 Remove the Battery Cover Push down the indent portion of Battery Cover and slide it into the direction of the arrow 3 Insert two AAA Batteries with the polarities in the correct direction 4 Close the Battery Cover Close the Battery Cover by sliding it as shown in the Figure until it clicks Battery Replacement e High performance alkaline dry cell batteries 2 AAA should be good for approximately 300 readings e Battery life varies with ambient temperature Battery life is shorter under cold conditions such as during the winter If the battery replacement symbol blinks while measuring or if pressure is not applied when the START STOP button is pressed replace both batteries use the same brand Holding the START STOP button down may shorten battery life To avoid pressure on the button when transporting or storing use the case provided If the batteries have been replaced or removed resetting of the date and time is required If you are not going to use this monitor for a long period of time approximately three months or more remove the batteries
12. en 2 Select Left Wrist or Right Wrist e The initial setting is LEFT at the time of your purchase WRIST LEFT IGHT siy y DN To change the setting to RIGHT push the button i Measuring Wrist Right Wrist Screen e If you want to change the setting to LEFT after having set to RIGHT push the button Lock the setting If you are also going to change other settings push the SET button to lock the setting e When you push the SET button the display changes to an Alarm Screen If you want to finish after locking the setting push the START STOP button to turn off the power 11 Alarm Setting You can set the alarm to go off twice a day at a specified time in the morning and evening e You can stop the alarm by pushing any of the buttons of this blood pressure monitor e Alarm will stop automatically after sounding for 2 minutes e Alarm will not sound when this monitor is in use such as for measurement the Memory Call Screen and the Graph Call Screen 1 Push the SET button while the power is turned off ALARH SET Keep pressing the button until the Alarm z gt AN 8 F00 Screen is displayed fH 3 00x 2 Set the Alarm Alarm Screen e The initial setting is amp not to go off at the time of your purchase Example of Alarm setting If you want to set the alarm to go off at 6 30 A M and 8 P M Push the 4 button to set the Hour to AM 6 ALARM S
13. ervice Dept together with 5 00 for return shipping and insurance Be sure to include the model number of your unit your name and address and your phone number on any correspondence We will either repair or replace at our option free of charge any parts necessary to correct defects in the materials or workmanship The above warranty is complete and exclusive The warrantor expressly disclaims liability for incidental special or consequential damages of any nature Some states do not allow the exclusion or limitation of incidental or consequential damages so the above warranty may not apply to you Any implied warranties arising by the operation of law shall be limited in duration to the term of this warranty Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state As a condition to operation of your warranty the enclosed registration card must be completed and sent to us within 10 days from the date of purchase FOR CUSTOMER SERVICE CALL TOLL FREE 1 800 634 4350 30 Notes 31 Manufactured by OMRON Distributed by OMRON HEALTHCARE INC 300 Lakeview Parkway Vernon Hills Illinois 60061 www omronhealthcare com Copyright 2003 OMRON HEALTHCARE INC 637INST Rev A
14. n irate oie ene Rete Bena otencasest dee sess odee cas wetsencabse oaun cases yea 28 Specifications cepere ma iea Aa E SE E aS ER E AR EAR A 29 W rranty serris tortne Tenet EEEa EPEETAN e E tw siete sua sa DENE eek 30 NOTES 225 nied ns Sankt ee eaea A AN A E eRT A RAA RAAS 31 Introduction Thank you for purchasing the Omron HEM 637 Wrist Blood Pressure Monitor with Advanced Positioning Sensor APS This remarkable instrument is ideal for people who frequently monitor their own blood pressure because it s so compact and easy to use There is no tricky arm cuff just a small pre formed wrist cuff that is easy to apply With the push of a button the Omron Wrist Monitor measures your blood pressure and pulse and displays the reading on a clear digital panel Perfect for quick easy readings at home at work and while traveling The Omron Wrist Monitor uses the oscillometric method of blood pressure measurement This means the monitor detects your blood s movement through the artery in your wrist and converts the movements into a digital reading An oscillometric monitor does not need a stethoscope so the monitor is simple to use and measurements are easy to obtain Clinical research has proven a direct relationship between blood pressure in the wrist and blood pressure in the arm Changes in wrist blood pressure reflect changes in arm blood pressure because the arteries in the wrist and the arm connect Frequently measuring the blood pressu
15. n reception which can be determined by turning the product on and off the user is encouraged to try to correct the interference by one or more of the following measure e Reorient or relocate the receiving antenna Increase the separation between the product and the receiver e Connect the product into an outlet on a circuit different from that to which the receiver Consult the dealer or an experienced radio TV technician for help POTENTIAL FOR RADIO TELEVISION INTERFERENCE for Canada only This digital apparatus does not exceed the Class B limits for radio emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital Apparatus ICES 003 of the canadian Department of Communications Cet appareil numerique respecte les linites de bruits radioelectriques applicables aux appareils numeriques de Classe B prescrites dans la norme sur le materiel brouileur Appareils Numeriques NMB 003 edictee par le ministre des communications 28 Specifications Name OMRON Wrist Blood Pressure Monitor with Advanced Positioning Sensor APS Model HEM 637 Display Digital display Measurement Oscillometric method Measurement Range Pressure 0 to 299 mmHg Pulse rate 40 to 180 min Accuracy Pressure within 3 mmHg Pulse rate within 5 of reading Inflation Automatic inflation with pump Deflation Automatic rapid deflation Pressure De
16. n under the present setting Automatic Memory ON Screen If you want to finish setting here push the START STOP button to turn off the power 16 How to Apply the Wrist Cuff How to wrap the wrist cuff is one of the most important points for correct measurement Wrap the cuff snugly on your wrist This monitor is preset to measure on your left hand when you purchased it If you desire to measure on your right hand change the mode to Right Hand measurement in setting e Wrap the wrist cuff over your skin Please be careful not to catch the cuff of your shirt How to wrap the wrist cuff correctly on left wrist 1 Place the wrist cuff over your left wrist with your left thumb facing upward Cover the wrist cuff by leaving clearance of 1 2 inch the clearance almost equal to the width of an index finger between the edge of the wrist cuff and the bottom of the palm as shown in the Figure to the right Check if the wrist cuff completely covers your wrist as shown in the Figure to the right 17 How to Wrap the Wrist Cuff 2 Pull the wrist cuff upward holding the edge of the wrist cuff so that it can be wrapped snugly e If the wrist cuff is not wrapped snugly correct measurement may not be possible Lightly press the velcro part with your finger so that it is fastened tightly If the velcro part is not tightly fastened the wrist cuff will become loose during measurement and th
17. nt values If you use the monitor without setting the date and time correctly the measured values will be stored with the wrong date and time In the following cases it is necessary to set the date and time e When you use the monitor for the first time e After replacing the batteries e After reset settings 1 Push the SET button while the power is turn off Keep pressing the button until the Time Screen TIME SET is displayed Alano 2002 V1 The year in Gregorian calendar is shown in flash display as the Time Screen appears AM 12 00 Time Screen 2 Push the 4 gt button to set the year to the current year in Gregorian calendar 3 Push the SET button 4 Push the 4 b button to set the Month to the current month 5 Push the SET button 6 Push the 4 b button to set the Day to the current day 14 Date and Time Setting continued 7 Push the SET button TIME SET 2002 1225 8 Set the Hour and Minute gt AW 2 00 F lashin Screen The hour can be set between 12 A M and 11 A M 8 and 12 P M and 11 P M ot Pone AMA TIME SET 2002 1 25 Example of setting the time at the time tone for 8 A M F AM 8x 00 1 Set the hour to AM 8 in advance Flashing Screen of Hour AM 8 TIME SET 2 Set the minute display to flashing 59 and push 2002 1 25 the button on the instant when the time tone AN 82 pag is heard At the moment you push the arrow button Flashing S
18. omRON Wrist Blood Pressure Monitor with Advanced Positioning Sensor APS Mesi Model HEM 637 Thank you for purchasing the Omron Wrist Blood Pressure Monitor with APS Contents Tntroductioiis so2 0 ee Seen Sieh AET EE utente tidy E ETA PESEE bis 3 KNOW OUR Unit rere ton achat siete as aaah aid Seat O R AA eo a ess 4 5 Suggestions Before Measuring Blood Pressure 0ececeeeeceeeeeeee eee es 6 Initial Set Up Battery Installation Replacement cece cece ee ec ee eeeneeee een ees 7 8 Automatic Memory Setting 2 0 0 0 cece eee c tere e nese ee eeeeeeen eens 9 Advanced Positioning Sensor APS Setting cc eee eee eee e eee 10 Wrist Selection Setting 3 6 2 wiete leeds de a dade faces beet 11 Alarm Setting a reac nuke sad ceva csinedte serene tonne nan E aed toate 2 Date and Time Settings serere a Eaa EEE RA EEEE E eae How to Reset this Monitor Correct Usage How to Apply the Wrist Cuff s s ssssssrssssssrsrsrssrsrsrererrererereree 17 How to Wrap the Wrist Cuff ssia ianen o diain e Ea a EES 18 How to Measure Blood Pressure sssissssssrerererrererererrererere 19 21 How to Use the Memory Function ssssissssssrsrsrererrerereresrerereree 22 Memory Reset Funt O E ES 23 How to Use the Graph Function 0 00 0 0 0 cec ee eeceenee nese ees 24 25 Troubleshooting estes secede se a E E dees E A deaett es 26 Care and Maintenance coddani e tivts dae deisel it 27 Cautio
19. ore up to 90 measurement results When you push the MEMORY button the monitor displays the measured values together with the date and time For the 91st measurement and onward the measured values are deleted from the oldest one To delete all the stored data use the Setting Mode If the monitor is set to OFF in the Setting Mode the monitor does not store the measured values e The measured values are retained in memory even after the batteries are removed for battery replacement ff omon pua oaro The latest measured values that are stored in memory are displayed with the M mark T31 1 40 1 Push the MEMORY button BPH mmHg U J Z 2 Check the memory Each time you push the 4 button the latest measured values are displayed If you push the button the screen moves backward es to the previous one H pre 1 8 If you push the gt button while the latest DIA measured values are being displayed the Date and BPH mmia 5 Time of oldest measured values are displayed Measurement If you push the GRAPH button during the memory display you can see the measured values of one week including the called out measured values in graph display If you push the MEMORY button again the screen returns to the memory display 1 5 M erie uh ay ert AN a 7 1 3 Push the START STOP button to turn off the power 22 Memory Reset Function
20. re in your wrist will provide you and your doctor with an accurate indication of changes in your true blood pressure Please read this instruction manual thoroughly before operating the Omron Wrist Blood Pressure Monitor with Advanced Positioning Sensor APS to assure proper use For specific information on your own blood pressure CONTACT YOUR PHYSICIAN Know Your Unit Main unit Wrist Cuff Wrap the wrist cuff over your wrist snugly Battery Cover Insert the batteries Two AAA Alkaline batteries LR03 eC e D Carrying Case QY IntelliSense Technology Is An Assurance of Accuracy Blood pressure changes throughout the day IntelliSense technology was developed by Omron which enables your blood pressure monitor to inflate and deflate at the optimum level for each individual This helps ensure accurate measurement and is particularly useful for people with certain arrythmia or heart disorders Advanced Positioning Sensor APS Ensures a Reliable Measurement Correct cuff positioning is critical when monitoring blood pressure The Omron Wrist APS Blood Pressure Monitor has a unique positioning sensor that confirms the cuff is level with the user s heart This helps ensure that each reading is accurate and reliable Systolic Blood Pressure Display Diastolic Blood Pressure Display Date Time Display i Mark Displayed when the stored measurement values are called out Pulse Display lt
21. se rate date and time are displayed e If the velcro opens during measurement SYS wrap the wrist cuff snugly again fasten the F amid velcro securely and start measurement again For If t to st rement push th _ you want to stop measurement push the Measurement Results START STOP button Display Screen After the monitor stops inflation and deflates the power turns off automatically 20 How to Measure Blood Pressure continued How to see the measurement results in enlarged characters If you push the gt button while the measurement results are displayed the results will be displayed in enlarged characters repeatedly in the order of systolic blood pressure diastolic blood pressure and pulse rate SYS 118 anata DIA mmHg an 118 DIA min BPH mmHg I If you push the 4 button while the measurement results are displayed the results will be displayed in enlarged characters repeatedly in the order of pulse rate diastolic blood pressure and systolic blood pressure PULSE DIA 8 gt 118 See mhg DIA mhg BPH mmhg 4 To stop measurement Push the START STOP button to turn off the power Even if you forget to push the START STOP lt J button the power will turn itself off automatically in approximately two minutes 21 How to Use The Memory Function This monitor has a memory function to st
22. tection Electrostatic capacity semi conductor pressure sensor Power Supply Two AAA batteries Battery Life Approximately 300 times of measurement when using alkaline batteries In case of the monitor is used three times a day inflating to 170 mmHg at the room temperature of 72 F Operating Temperature and Humidity 50 to 104 F 30 to 85 RH Storage Temperature and Humidity 4 to 140 F 10 to 95 RH Measurable Circumference of Wrist 51 to 81 2 Weight of Main Unit Approximately 5 2 oz not including batteries External Dimensions 3 W x 2 2 H x 1 D not including the wrist cuff Electric Shock Protection Internal power supply appliance type B Accessories Two AAA alkaline batteries Carrying case Illustrated Instruction Manual Note These specifications to improve performance are subject to change without notice 29 Limited Five Year Warranty Your Omron HEM 637 Wrist Blood Pressure Monitor with Advanced Positioning Sensor APS is warranted to be free from manufacturing defects for a period of five years under normal use The five year warranty excludes the monitor cuff The cuff is warranted for a one year period This warranty extends only to the original retail purchaser Should repair be needed within the warranty period ship the unit prepaid to Omron Healthcare Inc 300 Lakeview Parkway Vernon Hills IL 60061 Attn S
23. ton to turn off the power How to see the graph Date of Blood Pressure Values How to see the graph is explained by using the ee era example of All Data Graph 1 31 pa When you push the GRAPH button the latest Ma W Il I measurement results appear in flashing display fl In the example shown to the right measurement is n i made at 10 40 p m on January 31 The graph shows G Z A G that the systolic blood pressure is 140 mmHg top of the vertical bar the diastolic blood pressure is 95 Pulse mmHg bottom of the vertical bar and the pulse rate Month Days Rate of a Week is 90 a minute B The data in flashing display When you push the MEMORY button during the graph display the details of data in flashing display appear with the M mark You can also change the flashing BPH rita position by pushing 4 or button Detail Screen of Data When you push the GRAPH button again in Flashing Display the graph display appears For the people with hypertension Display of the graph when the systolic blood pressure is higher than 170 mmHg e If the systolic blood pressure values that are higher than 170 mmHg are measured twice a symbol meaning that the systolic pressure is higher than 170 mmHg is displayed on the graph Wal 70 e If the systolic blood pressure values that Ha Mii are higher than 170 mmHg are stored cag ete m three times the symbol disappears e aH and the screen automaticall
24. y changes Display screen Graph Display to display the hypertension type graph where the systolic Sereen of capable of displaying 210 mmHg blood pressure Hypertension Type values higher than 170 mmHg are measured twice 25 Troubleshooting Error Cause How to correct TE E JE Measure your blood this fis pressure again without v HEIGHT 58 ong ron After several seconds You moved your wrist during measurement moving your wrist until the measurement is completed 125 T E15 E B16 i 0 a 98 Y After several seconds You moved your arm or body or talked during measurement Measure your blood pressure again without moving your arm or body 1725 am 515 E mag After several seconds You moved your arm or body extensively during measurement Measure your blood pressure again without moving your arm or body Battery replacement mark flashes Batteries are worn out Replace both batteries with new ones E 025 Only E and numerals are displayed Trouble caused by abnormality in function Please contact the nearest OMRON Healthcare Inc Customer Service 26 Care and Maintenance To keep your digital wrist blood pressure monitor in the best condition and protect the unit from damage follow the directions listed below e Clean the monitor with a soft dry cloth Do not use any
Download Pdf Manuals
Related Search
Related Contents
MOVIMOT® MM..B in Kategorie 3D (Staub Jump Starter &Air Compressor12Ah Manuel d`opération et de maintien PS 3.29 PS 3.31 安全衛生管理水準の さらなる向上を目指します Progress Lighting P2978-09 Instructions / Assembly Samsung AQV09VBCN Manuel de l'utilisateur HORSCH Pronto 6 AS Betriebsanleitung Manual de usuario - Portal de Mendoza アライメントステージ CMX Copyright © All rights reserved.