Home
NuTone NP629004 User's Manual
Contents
1. Use an extinguisher ONLY if A You know you have a Class ABC extinguisher and you already know how to operate it B The fire is small and contained in the area where it started C The fire department is being called D You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA Ds CAUTION 1 2 3 4 go 10 11 To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages Take care when using cleaning agents or detergents Avoid using food products that produce flames under the Range Hood For general ventilating use only Do not use to exhaust hazardous or explosive mate rials and vapors To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit Y our hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated The motor will restart when it cools down If the motor continues to shut off and restart have the hood serviced For best capture of cooking impurities the bottom of the hood should be a minimum of 24 and a maximum of 30 above the cooking surface Two installers are recommended because of the large size and weight of this hood This product is equipped with a thermostat which may start blower automatical
2. 49 8 126cm si la distance entre la hotte et le plan de cuisson c est de 30 VIS D ASSEMBLAGE 4 8x38mm TROUS RECTANGULAIRES PLANCHE DE BOIS POUR L ADAPTATION VIS DE REGLAGE EN PROFONDEUR VIS DE a REGLAGE EN HAUTEUR INSTALLATION ELECTRIQUE COUVERCLE DE LA BO TE DE CONNEXION Remarque Ce mod le de hotte doit tre reli la terre correctement Cet article devrait tre install par un lectricien qualifi selon les lois nationales et locales en mati re d lectricit 1 Enlevez le couvercle de la bo te de connexion lectrique Ouvrez un trou de la bo te de connexion lectrique 2 Fixer le conduit au bo tier de connexion l aide d un connecteur appropri pour ce conduit 3 Faites le raccordement lectrique Reliez le blanc au blanc le noir au noir et le vert au vert 4 Remettez le couvercle de la bo te de connexion et les vis Assurez vous que les fils se sont pas coinc s entre le couvercle et la bo te CONNEXION DU SYSTEME D EVACUATION 1 Fixez l trier d assemblage du conduit au plafond ou au mur comme cela est indiqu l aide des vis 4 8x38mm et des chevilles qui vous sont fournies 2 Utilisez un tuyau rond en m tal de 6 pour relier le collier du tuyau qui se trouve sur votre hotte au systeme d vacuation qui se zs Se 4 8x38mm trouve au dessus 3 Utilisez du ruban pour tuyauterie pour que les j
3. INSTALACION DEL TUBO DECORATIVO CABLE DE 1 Mantenga el tubo decorativo cerca de la parte superior de la campana Enchufe el cable de mandos de la campana al tubo decorativo como se indica 2 Deslice la parte inferior del tubo decorativo hacia abajo e introd zcala en CONDUCTOS 5 i pa a PARTE os conductos de la campana INFERIOR DEL TUBO DECORATIVO CONDUCTOS 3 Suba la parte superior del tubo decorativo PARTE SUPERIOR DEL TUBO y eng nchela en el soporte para el montaje DECORATIVO del tubo por medio de tornillos adjuntos 7 3 9x9 5mm SUJETAR AL SUPORTE PARA EL MONTAJE DEL TUBO 95 MANTENIMIENTO Un mantenimiento adecuado de la campana asegura el funcionamiento correcto del aparato Filtros antigrasa Limpie el filtro antigrasa con frecuencia Tire de l hacia abajo para extraerlo y limpiarlo Use un detergente que no sea fuerte Los filtros antigrasa se pueden meter en el lavavajillas Una vez limpiado el filtro anti grasa proceda FILTROS ANTIGRASA de la siguiente manera para volver a montarlo 1 Quite las l mparas hal genas 2 Monte el filtro anti grasa 3 Monte las l mparas hal genas Limpieza del interior de la campana ANTES DE LIMPIAR LA CAMPANA DESCONECTELA DE LA RED 1 Extraiga el filtro antigrasa come se ha indicado anteriormente 2 Extraiga las lamparas hal genas Consulte el capitulo LAMPARAS HALOGENAS ee 3 Extraiga la rejilla de metal
4. si la distancia entre la campa na y la zona de cocci n es de 30 AGUJEROS TORNILLOS PARA RECTANGULARES MONTAJE 4 8x38mm SOPORTES DE MONTAJE ESTRUCTURA DE MADERA _ EN LA PARED TORNILLOS PARA LA REGULACION DE LA PROFUNDIDAD TORNILLOS PARA LA REGULACION DE LA ALTURA INSTALACION ELECTRICA Nota Este tipo de campana tiene que ser conectada a tierra cuidadosamente La unidad debe instalarla un t cnico electricista siguiendo las normas nacionales y locales 1 2 Quite la tapa de la caja de conexi n el ctrica y saque un cable Fije el conduit a la caja de conexi n por medio de un conector id neo para el conduit Haga las conexiones el ctricas una blanco con blanco negro con negro y verde con verde Vuelva a conectar la tapa de la caja de conexi n Compruebe que los cables no queden pillados ENTUBADO DE CANALIZACION 1 Use tornillos 4 8x38mm y escarpias adjuntos para fijar en el techo o en la pared el soporte para el montaje del tubo como se indica Use el tubo de metal de 6 de di metro para unir el casquillo situado arriba de la campana al tubo que est arriba Use la cinta para unir todas las junturas y que el tubo quede herm tico 24 TAPA DE CONEXI N EL CTRICA SOPORTE PARA EL a MONTAJE DEL TUBO TORNILLOS DE MONTAJE 4 8x38mm DECORATIVO METAL DE 6 DE DIAMETRO
5. AU CAS O VOTRE CUISINI RE PRENDRAIT FEU OBSERVEZLES INSTRUCTIONS SUIVANTES 1 ETEINDRE LES FLAMMES l aide d un couvercle le plus herm tique possible une plaque g teaux ou un plateau en m tal puis teindre le br leur ATTENTION NE PAS VOUS BRULER Si les flammes ne s teignent pas imm diatement SORTEZ ET APPELEZ LES POMPIERS NE PRENEZ JAMAIS EN MAIN UNE PO LE OU UNE CASSEROLE QUI A PRIS FEU Vous pourriez vous br ler N UTILISEZ PAS D EAU ni torchons ou serviettes mouill s vous provoqueriez une violente explosion de vapeur 11 Utilisez un extincteur SEULEMENT si A Vous savez que vous avez un extincteur Classe ABC et vous en connaissez d j le mode d emploi B Ce n est pas un tr s gros incendie et qu il se limite l endroi o il a explos C Vous tes en train d avertir les pompiers D Vous avez la possibilit d essayer d teindre l incendie en ayant le dos tourn vers une issue D apr s les Suggestions concernant la S curit contre les incendies des cuisines publi es par NFPA ATTENTION 1 A Q 10 11 Pour r duire tout risque d incendie et pour vacuer correctement l air assurez vous de pr voir un conduit de ventilation ext rieur Ne videz pas l air dans les espaces limit s par des murs ou des plafonds les combles les passages troits ou les garages Faites tr s attention quand vous utilisez des produits de nettoyage o
6. Heating Refrigeration and Air Conditioning Engineers ASHRAB and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors Do not use this unit with any separate solid state speed control device To reduce the risk of fire use only metal ductwork This unit must be grounded O REDUCE THE RISK OF A RANGE TOP GREASE FIRE Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings Always turn hood ON when cooking at high heat or when cooking flaming foods i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambe Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP A FLAMING PAN You may be burned DO NOT USE WATER including wet dishcloths or towels violent steam explosion will result
7. MR16 12V 20W To change bulbs 1 Remove the grease filter 2 Remove bulbs by pulling them straight downward Do not rotate bulbs 3 Remount the grease filter 4 Replace bulbs by aligning the bulb s pins with the receptacle holes and pushing bulb upward FUSE REPLACEMENT SWITCH OFF THE ELECTRICITY SUPPLY Push the lower flue upwards Open the electrical box Replace with the same type of fuse 5x20mm 4A 125V WARRANTY BROAN NUTONE LLC ONE YEAR LIMITED WARRANTY Broan NuTone LLC warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase THERE ARE NO OTHER WAR RANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this one year period Broan NuTone LLC will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS TUBES HALOGEN AND INCANDESCENDT BULBS This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone LLC faulty installation or installation contrary to recommended installation instructions The duration of any im
8. codes l 2 3 Remove the wiring box cover Remove a knockout from the wiring box Secure the conduit to the wiring box through a conduit connector Make electrical connections Connect white to white black to black and green to green Replace wiring box cover and screws Make sure that wires are not pinched between cover and box CONNECT DUCTWORK iL Use screws 4 8x38mm and wall anchors provided to secure flue mounting bracket to the ceiling or wall as shown Use 6 round metal duct to connect the duct collar on the hood to the ductwork above Use duct tape to make all joints secure and air tight FLUE MOUNTING _ BRACKET MOUNTING SCREWS 4 8x38mm DECORATIVE _ FLUE DUCT TAPE FL 6 ROUND METAL DUCT INSTALL DECORATIVE FLUE SSeS SWITCH 1 Hold the decorative flue near the top of the CABLE hood Connect the switch cable from the hood to the decorative flue as shown 2 Slide the lower decorative flue section downward and into the channels on the CHANNEL hood LOWER DECORATIVE FLUE SECTION CHANNEL 3 Raise upper decorative flue section and attach it to the flue mounting bracket with screws supplied 3 9x9 5mm UPPER DECORATIVE FLUE SECTION FASTEN TO FLUE MOUNTING BRACKET MAINTENANCE Proper maintenance of the Range Hood will assure proper performance of the unit Grease Filter Clean the grease filter frequenil
9. normes Quand vous coupez ou percez des trous dans le mur ou le plafond n abimez pas les fils lectriques ou autres Leventilateur canalis doit toujours vacuer l air vers l ext rieur N utilisez pas cet appareil avec un appareil contr lant la vitesse tat solide Afin de diminuer tout risque d incendie n utilisez que des conduits en m tal Votre appareil doit tre reli la terre ATTENTION POUR REDUIRE LES RISQUES D INCENDIE DES MATIERES GRASSES QUI SONT EN TRAIN DE CUIRE A Ne laissez jamais ni vos l ments chauffants ni vos casseroles ou po les sur le feu sans les contr ler si vous r glez l apport de chaleur sur une position lev e Si vos casseroles ou po les d bordent cela provoque de la vapeur et des claboussures de graisse qui peuvent prendre feu Chauffez les huiles lentement feu bas ou moyen Faites toujours fonctionner votre hotte quand vous cuisez des temp ratures lev es ou quand vous cuisinez des plats flamb s par ex cr pes Suzette Cerises Jubil Steack au poivre flamb Nettoyez r guli rement les ailes de vos ventilateurs Ne permettez pas que la graisse s accumule sur le ventilateur ou sur le filtre Utilisez des casseroles de taille appropri e Utilisez toujours des ustensiles de cuisson dont la taille est appropri e la surface de votre l ment de cuisson AVERTISSEMENTS POUR REDUIRE LES RISQUES DE DOMMAGES AUX PERSONNES
10. CKETS 1 Construct wood wall framing that is flush with interior surface of wall studs Make sure a the framing is centered over installation location b the height of the framing will allow the mounting brackets to be secured to the framing within the dimensions shown After wall surface is finished secure mount ing brackets to framing at dimensions shown using screws provided INSTALL THE HOOD 1 Hang the hood from the brackets through the rectangular cut outs on the back of the hood Cut outs are larger than the brackets to allow for horizontal adjustment The bottom of the hood should be 24 to 30 above the cooking surface Height adjustment screws provide vertical adjustment Depth adjustment screws provide hori zontal adjustment Secure the hood with mounting screws 4 8x38mm Use drywall anchors provided if wall studs or framing are not available ROOF CAP DECORATIVE FLUE 24 TO 30 ABOVE COOKING SURFACE FAEERE EIEEE REEE F A ee ee F 435 s bottom of hood 24 above cooktop 495 s bottom of hood 30 above cooktop MOUNTING RECTANGULAR SCREWS CUTOUTS 4 8x38mm IS MOUNTING BRACKETS FRAMING DEPTH ADJUSTMENT SCREWS a HEIGHT A ADJUSTMENT SCREWS WIRING Note This range hood must be properly grounded The unit should be installed by a qualified electrician in accordance with all applicable national and local electrical
11. DES ETRIERS D ASSEMBLAGE 1 Construisez un cadre en bois pour le mur 2 dont les vis pivot ne d passent pas Assurez vous a que le cadre est centr au dessus de emplacement de l installation b la hauteur du cadre permettra que les triers d assemblage soient fix s au cadre en respectant les dimensions indiqu es Apr s avoir termin la surface du mur fixez les triers d assemblage au cadre en respectant les dimensions qui sont indiqu es INSTALLATION DE VOTRE HOTTE 1 Accrochez votre hotte aux triers par les trous rectangulaires qui se trouvent derri re votre hotte Les trous sont plus grands que les triers afin de vous permettre d ajuster le tout horizontalement Le fond de votre hotte devrait tre entre 24 et 30 au dessus de la surface de cuisson Les vis de r glage en hauteur permettent de r gler verticalement Les vis de r glage en profondeur permettent de r gler horizontalement Fixez votre hotte avec des vis d assemblage 4 8x38mm Utilisez des chevilles pour mur sec qui vous sont fournies si vous ne trouvez pas les vis pivot ou le cadre A COUVERCLE DU TOIT CONDUIT ee D CORATIF S N oR ch N N N HOTTE A COUDE ROND DE 6 DE 24 30 AU DESSUS DU PLAN DE CUISSON pem a p CADRE POUR LE MUR 435 s 110 8cm si la distance entre la hotte et le plan de cuisson c est de 24
12. E DECHARGES ELECTRIQUES OU DE DOMMAGES AUX PERSONNES OBSERVEZ LES INSTRUCTIONS SUIVANTES 1 OOND O1 N utilisez cet appareil que comme cela estindiqu parle constructeur Si vous avez des problemes contactez le fabriquant l adresse ou au num ro de t l phone indiqu s dans la garantie Avant de pourvoir l entretien ou au nettoyage de votre appareil teignez le au tableau des commandes ou bloquezle tableau des commandes afin d viter de le mettre en marche accidentellement Si vous ne pouvez pas bloquer le syst me permettant d teindre votre appareil appliquez un avertissement ext rieur d une fa on sure comme par exemple un panneau surle tableau des commandes L assemblage etla connexion lectrique doivent tre faits par des personnes qualifi es enrespectantles normes et r glements en vigueur y compris les normes et r glements concernantles possibilit s d incendie llestindispensable qu il y ait suffisamment d air pour que la combustion etl vacuation des gaz travers le tuyau du br leur du combustible ait lieu sans retour de flamme Suivez les indications donn es parle fabricant du br leur ainsi que les normes de s curit comme celles qui sont publi es par l Association Nationale pour la Protection contre les Incendies National Fire Protection Association NFPA etla American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE etles autorit s locales en mati re de
13. E LOS SOPO RTES PARA EL MONTAJE 1 Construya una estructura de madera en la pared que quedar nivelada con la parte interior de los tacos en la pared Aseg rese de que a La estructura se encuentra centrada por encima de la instalaci n del tubo b La altura de la estructura permite fijar los soportes para el montaje en esta estructura siguiendo las dimensiones indicadas 2 Una vez que la superficie de la pared est acabada sujete los soportes para el montaje siguiendo las dimensiones indicadas INSTALACION DE LA CAMPANA 1 Cuelgue la campana de los soportes por los agujeros rectangulares situados detr s de la campana Los agujeros son m s grandes que los soportes para permitir el ajuste en horizontal La parte inferior de la campana debe estar a una distancia de 24 30 por encima de la zona de cocci n Los tornillos para la regulaci n de la altura permiten un ajuste en vertical Los tornillos para la regulaci n de la profundidad permiten un ajuste en horizontal Sujete la campana con tornillos para montaje 4 8x38mm Use escarpias si no dispone de tacos o de la estructura de soporte en madera 23 CUBIERTA DEL TEJADO TUBO DE 6 DE DIAMETRO TUBO ES DECORATIVO CAMPANA 24 A 30 POR ENCIMA DE LA ZONA DE COCCION E AS A A ee F 43 8 110 8cm si la distancia entre la cam pana y la zona de cocci n es de 24 49 8 126cm
14. EQUENCE Quelques tats ne permettent pas l exclusion ou la limitation des dommages accidentels ou cons quentiels par cons quent la limitation indiqu e ci dessus peut ne pas vous concerner Cette garantie vous donne des droits l gaux sp cifiques et vous pouvez aussi avoir d autres droits qui varient d Etat Etat Cette garantie d passe toute garantie pr c dente Pour avoir droit la garantie vous devez a avertir la Maison Broan NuTone LLC l adresse indiqu e ci dessous ou t l phoner 1 800 637 1453 b donner le num ro du mod le et l identification de la pi ce d fectueuse et c d crire la nature de tout d faut de l article ou de la pi ce Au moment o vous demandez le service de garantie vous devez pr senter la preuve d achat avec la date Broan NuTone LLC 926 West State Street Hartford WI 53027 1 800 637 1453 NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 1 800 543 8687 LEA Y CONSERVE ESTAS INSTRUCCIONES INDICADO PARA EL USO ENCOCINAS DOMESTICAS ADVERTENCIA PARA EVITAR EL RIESGO DE INCENDIO CORTOCIRCUITO O DANO PARA LAS PERSONAS OBSERVE ATENTAMENTE LAS SIGUIENTES NORMAS 1 Use esta unidad solamente de la manera indicada por el fabricante si tiene dudas p ngase en contacto con ste a la direcci n o tel fono indicados en la garant a 2 Antes de hacer una revisi n o de limpiar la unidad descon ctela de la red para evitar que se encienda de manera accidental En el ca
15. ER Enlevez le filtre anti graisse comme cela est indiqu plus haut Enlevez les ampoules Voir AMPOULES HALOGENES la page suivante GRILLE EN _ METAL L quatre 4 vis qui la fixent Lavez l int rieur de votre hotte au moyen d un chiffon doux impr gn d une solution contenant un d tergent neutre Remonter le filtre anti graisse Remettre en place les ampoules halog nes Nettoyage de l xterieur de votre hotte L acier inoxydable est une des mati res les plus faciles nettoyer Un entretien de temps en temps permettra de le conserver en parfait tat Conseils pour le nettoyage Eau chaude et savon ou d tergent est tout ce qui est normalement n cessaire Apr s chaque nettoyage rincez bien l eau claire Essuyez avec un chiffon propre et doux afin d viter les taches d eau Si des d colorations ou des d p ts persistent utilisez un nettoyant domestique non abrasif ou de la poudre pour l acier inoxydable et un peu d eau et un chiffon doux Dans les cas difficiles utilisez une ponge en plastique ou une brosse douce avec du nettoyant et de l eau Frottez l g rement en suivant la direction du polissage ou du grain de l acier inoxydable Evitez de frotter trop fort afin de ne pas ab mer la surface NE LAISSEZ PAS les taches trop longtemps N UTILISEZ PAS de laines d acier ordinaires ou des brosses en acier Des d bris d acier pourraient adh rer a la surface et cause
16. IE EXPLICITE OU IMPLICITE Y COMPRIS MAIS NON PAS LIMIT E A LES GARANTIES IMPLICITES OU CONCERNANT LA CAPACITE COMMERCIALE OU LA CONVENANCE POUR TOUT BUT PARTICULIER Pendant cette p riode d un an Broan NuTone LLC r parera ou remplacera s il le jugera n cessaire gratuitement tout article ou toute pi ce qui r sulteront d fectueux condition qu ils aient t utilis e et entretenu correctement CETTE GARANTIE NE S ETEND PAS AUX INTERRUPTEURS DES NEON NEON LAMPES HALOGENES AMPOULES d ILLUMINATION Cette garantie ne couvre pas a l entretien normal ni b tout article ou toute pi ce qui aient subi une utilisation erron e une n gligence un accident un entretien erron ou une r paration autre que de la part de Broan NuTone LLC une installation d fectueuse ou bien une installation ne respectant pas les instructions d installation recommand es La dur e de toute garantie implicite est limit e un an comme cela est sp cifi dans la garantie explicite Quelques tats ne permettent pas de limites quant la dur e d une garantie implicite par cons quent la limitation indiqu e ci dessus peut ne pas vous concerner L OBLIGATION DE REPARER OU DE REMPLACER DE LA PART DE BROAN NUTONE LLC SERA LE SEUL ET EXCLUSIF REMEDE DE L ACHETEUR COUVERT PAR CETTE GARANTIE BROAN NUTONE LLC NE SERA PAS RESPONSABLE DES DOMMAGES ACCIDENTELS CONSEQUENTIELS OU SPECIAUX DUS A L UTILISATION DU PRODUIT O A SA PERFORMANCE OU EN ETANT LA CONS
17. Model NP629004 3 D O O yA ENGLISH 2 FRANCAIS 11 O 20 Broan NuTone LLC 926 West State Street Hartford WI 53027 NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 REGISTER YOUR PRODUCT ONLINE AT www nutone com register READ AND SAVE THESE INSTRUCTIONS INTENDED FOR DOMESTIC COOKING ONLY WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 2 oqo CIO al U O WU gt P Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer at the address or telephone number listed in the warranty Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by a qualified person s in accor dance with all applicable codes and standards including fire rated construction codes and standards Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equip ment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for
18. aredes otechos ticos espacios angostos o garajes Prestar la m xima atenci n al utilizar productos de limpieza o detergentes Evitar el uso de productos alimentarios que puedan inflamarse bajo la campana S lo para ventilaci n total No use gases de escape peligrosos o materiales y vapores explosivos Para evitar da os en el funcionamiento del motor e impulsores ruidosos y o desequi librados mantenga alejados de la unidad de encendido pulverizadores en seco o polvo El motor tiene un nivel de sobrecarga t rmica que apaga autom ticamente el motor cuando se ha recalentado excesivamente El motor se pone de nuevo en fincionamento cuando la temperatura baja Si el motor comienza a encenderse y a apagarse deber hacer una revisi n de ste Para limpiar mejor las impurezas al cocinar la distancia entre la parte inferior de la campana y la zona de cocci n debe ser m nimo 24 maximo 30 Debido a su gran tama o y peso se recomienda su montaje por parte de dos t cnicos esperializados Este producto est dotado de un termostato que pone en marcha autom ticamente el motor Para reducir el riesgo de da os y evitar que se encienda accidentalmente colocar el interruptor del panel de servicio en la posici n OFF y bloquear el panel de servizio o colocar una advertencia externa como por ejemplo un letrero o una chapita 10 Use solamente con juego de conexi n para alimentaci n aprobado 11 Se recomienda leer la placa de
19. caracteristicas del producto para ulterior informaci n 21 2 PREPARE LA CAMPANA Sacar la campana de l embalaje y controlar el contenido Recivireis 1 Campana 1 Tubo decorativo 1 Bolsita B080810285 con 2 Soportes de montaje 8 Tornillos de montaje 4 8 x 38mm cabeza redonda 8 Escarpias 2 Tornillos de montaje 3 9 x 9 5mm cabeza redonda 2 Tornillos de montaje 3 9 x 9 5mm cabeza redonda negra 1 Soporte para el montaje del tubo 1 Instrucciones para instalaci n TUBO DECORATIVO SOPORTES DE MONTAJE 2 TORNILLOS DE MONTAJE 3 9 x 9 5mm cabeza redonda 2 TORNILLOS DE MONTAJE 3 9 x 9 5mm cabeza redonda negra SOPORTE PARA EL MONTAJE DEL TUBO 8 TORNILLOS DE 8 ESCARPIAS MONTAJE 4 8 x 38mm cabeza redonda 29 INSTALACION DEL TUBO DE EXTRACCION NOTA para evitar el riesgo de incendio use solamente material de metal ie Decida donde va a colocar el tubo de extracci n entre la campana y la parte exterior Un recorrido de tubo corto y recto permitir a la campana funcionar de manera m s eficaz Los recorridos largos de tubo codos y manguitos impiden el buen funcionamiento de la campana Use el menor n mero de ellos posible Instale una cubierta 6 una tapa Una el tubo de metal de 6 de di metro a la cubierta y retroceda hasta la posici n de la campana Use une cinta para precintar las juntas entre las partes del entubado INSTALACION D
20. ci n reparaci n distinta da la realizada por Broan NuTone LLC montaje incorrecto instalaci n que no se ajuste a las instrucciones de montaje indicadas Le duraci n de la garant a se limita al periodo de un a o como est especificado en la garant a explicita Algunos paises no permiten un limite en la duraci n de la garant a implicita si es asi en su caso esta limitaci n arriba indicada podr a no aplicarse LA PRESENTE GARANTIA CUBRIRA EXCLUSIVAMENTE AL COMPRADOR LOS SERVICIOS DESCRITOS ANTERIORMENTE BROAN NUTONE LLC NO SE HACE RESPONSABLE DE DANOS PRODUCIDOS DE MANERA ACCIDENTAL O RELACIONADOS CON EL USO INCORRECTO DEL PRODUCTO O SU FUNCIONAMIENTO Algunos paises no permiten la exclusi n o limitaci n de los da os producidos de manera accidental si es as en su caso esta limitaci n arriba indicada podr a no aplicarse Esta garant a le da derechos legales espec ficos y podr a tambi n disponer de otros derechos que varian de pa s a pa s Esta garant a supera otras garant as dadas con anterioridad Para disfrutar de la garant a usted deber a Avisar a la direcci n abajo indicada bien llamar por tel fono al n mero 1 800 637 1453 b Dar el n mero de serie del modelo correspondiente o bien una descripci n de la parte averiada c Descripci n del defecto en el producto o bien en una de sus partes Para requerir un servicio en garant a debe presentar el justificante con la fecha de la compra Broan NuTone LLC 926 We
21. e Package Duct Connector Assembly Includes Key Nos 56 57 Blower Assembly Includes Key Nos 48 49 53 68 69 42 Fuse Fuse Holder 29 LISTE PIECES DE RECHANGE NP62000 SERIES RANGE HOOD Ci dessous liste pi ces de rechange pour hottes en inox Pour les pi ces de rechange des mod les de couleurs noir ou blanc contacter Broan Customer Service ONO PARTN DESCRIPTION B03118083 BE3401653 B020002340 B02300233 B03295005 B02300774 B02300787 B03292357 B03294033 B03295001 B02310184 B03295071 B03204177 BE3334551 BE3403483 B02300206 B02011258 B02011259 B03202430 B03204094 BE3334250 BE3334252 B08091225 BE3400561 BE3334555 B03292287 B03295008 B08086697 B02300727 B03292296 B02300783 B08088323 BE3401651 BE3234559 BE3342289 BE3342302 BE3342303 B03295006 B080810285 B08092518 B06002019 B02300782 B02300674 illustr es separement Groupe moteur Ensemble filtre Ressort du filtre Condensateur Protection trasformateur Lampe halogene Capteur Boite installation electrique Couvercle boite installation electrique Support filtre Moteur Turbine du moteur Pare chocs Couvercle groupe moteur Grille en m tal Cable commandes Cocue moteur droite Cocue moteur gauche Garniture tube Garniture verre Boite de alimentation Couvercle boite de alimentation Tube inf rieur Tube sup rieur Etrier montage tube Serre cable Boite fusible Curcuit imprim installation electr
22. ejemplo Crepes Suzette Cerezas Jubilee Ternera flambeada con granos de pimienta Limpie con frecuencia los ventiladores No se debe acumular grasa en el ventilador o en el filtro D Usa el tama p de cazuela apropiado Use siempre utensilios de cocina de tama o y material adecuados gt U OONO ADVERTENCIA PARA EVITAR EL RIESGO DE DA OS A PERSONAS EN CASO DE FUEGO POR ALTO NIVEL DE GRASA TENGA EN CUENTA LO SIGUIENTE 1 SOFOQUE LA LLAMA con una tapadera apropiada una bandeja met lica un utensilio de coc na que pueda cubrirla despues apague el quemador ACTUE CON PRECAUCION PARA EVITAR QUEMADURAS Si la llama no se extingue inmedia tamente SALGA Y LLAME A LOS BOMBEROS 2 NUNCA COJA UNA SARTEN EN LLAMAS porque corre el riesgo de quemarse 3 NO USE AGUA ni pa os o toallas h midas porque puede provocarse una violenta humareda 4 Use un extintor SOLAMENTE si A Posee un extintor de clase ABC y sabe perfectamente c mo usarlo B Elfuego es peque o y est controlado en el mismo sitio en que empez C Hallamado con anterioridad a los bomberos D Puede combatir el fuego retroced endo hacia la salida Basado en Seguridad antifuego en la coc na publicado por NFPA 50e ADVERTENCIA 1 Para reducir el riesgo de incendios y para evacuar correctamente los humos asegurarse rs D de haber realizado una conducci n del aire hasta el exterior No expulsar los humos en espacios cerrados por p
23. el aspirador a su velocidad m s alta Este mando funciona aunque el aspirador no est en marcha El mando con timer hace funcionar el aspirador durante 10 20 minutos antes de apagarse autom ticamente Accione el mando una vez para indicar 10 minutos y dos veces si quiere indicar 20 minutos Este mando funciona solamente cuando el aspirador est en marcha El piloto situado encima del mando reset se iluminar cuando el aspirador haya funcionado durante 30 horas Entonces tendr que cambiar el filtro antigrasa Una vez que el filtro haya sido cambiado y colocado en su sitio accione el conmutador para que se apague la luz y empiece a contar otras 30 horas HEAT SENTRY Su campana esta equipada con termostato HEAT SENTRY Este termostato tiene un mecanismo que se encender o acelerat el ventilador si se detecta un calor excesivo encima de la cocina 1 Si el ventilador esta apagando el se prender a una velocidad m xima 2 Si el ventilador esta encendido a una velocidad minima el se prender a una velocidad m xima Cuando la temperatura disminuye a un nivel normal el ventilador vuelve a la funci n de origen AVERTENCIA El HEAT SENTRY termostato puede comenzar a funcionar al igual si la campana esta parada En este caso es imposible parar el ventilador con los interruptores Si usted para la campana halago a partir del panel el ctrico principal 07 LAMPARAS HALOGENAS Este tipo de campana necesi
24. ique Support ceramique lampe Protection lampe Trasformateur Ensemble commandes Panneau int rieur Couvercle Support ampoule halog ne Etrier droit verre Etrier gauche verre Couvercle protection trasformateur Accessoires de fixation Ensemble bride de raccordement Comprenant n 56 57 Ensemble moteur Comprenant n 48 49 53 68 69 42 Fusible Porte fusible 30 LISTA DE PIEZAS DE RECAMBIO NP62000 SERIES RANGE HOOD Aqu aparecen solamente las piezas de recambio para campanas de acero inoxidable si desean las piezas de recambio de los modelos en blanco negro p nganse en contacto con el servicio al cliente de Broan COD N PIEZAN DESCRIPCI N B03118083 Grupo motor BE3401653 Conjunto filtro B020002340 Muelle del filtro B02300233 Condensador B03295005 Protecci n trasformador B02300774 L mpara hal gena B02300787 Sensor B03292357 Caja base de instalaci n el ctrica B03294033 Tapa de la caja base de instalaci n el ctrica B03295001 Soporte filtro B02310184 Motor B03295071 Manilla del motor B03204177 Almohadille del motor BE3334551 Tapa grupo motor BE3403483 Reijlla de metal B02300206 Cabo mandos B02011258 Lado derecho del motor B02011259 Lado isquierdo del motor B03202430 Guarnici n B03204094 Guarnici n del cristal BE3334250 Caja de alimentaci n BE3334252 Tapa de la caja de alimentaci n B08091225 Tubo decorativo inferior BE3400561 Tubo decorativo superior BE3334555 Soporte de mo
25. le ventilateur fonctionne en basse vitesse le ventilateur tournera en haute vitesse Lorsque la temp rature revient la normale le ventilateur retourne sa vitesse d origine AVERTISSEMENT Le thermostat HEAT SENTRY peu actionner la hotte m me si la hotte est arr t e Si tel est le cas il est impossible de l arr ter avec l interrupteur Si vous devez arr ter le ventilateur faites le partir du panneau lectrique principal 18 AMPOULES HALOGENES Ce mod le de hotte a deux ampoules halog nes Type MR16 12V 20W Pour changer les ampoules 1 2 3 REMPLACEMENT FUSIBLE D BRANCHEZ L APPAREIL Poussez vers le haut le conduit inf rieur Ouvrir le bo tier installation lectrique Remplacez par un fusible du m me type 5x20mm 4A 125V Enlever le filtre anti graisse Enlever les ampoules en les tirant tout droit vers le bas Ne pas faire tourner les ampoules Remonter le filtre anti graisse Remettre les ampoules en alignant les fiches des ampoules avec les cavit s a l int rieur desquelles elles doivent tre ins r es et en poussant les ampoules vers le haut FUSIBLE GARANTIE GARANTIE BROAN NUTONE LLC LIMIT E A UN AN Broan NuTone LLC garantit au consommateur acheteur de ses produits que ces produits seront sans d fauts concernant les mati res employ es et concernant la fabrication pendant une p riode d un an partir de la date d achat IL N Y A AUCUNE AUTRE GARANT
26. ly To reduce the risk of injury and to prevent power from being switched on accidentally switch power off at Service panel and lock or tag service panel Use with approved cord connection kit only Please read specification label on product for further information and requirements PREPARE THE HOOD Unpack hood and check contents You should receive 1 Hood 1 Decorative Flue Assembly 1 Parts Bag B080810285 containing 2 Mounting Brackets 8 Mounting Screws 4 8 x 38mm Pan Head 8 Drywall Anchors 2 Mounting Screws 3 9 x 9 5mm Pan Head 2 Mounting Screws 3 9 x 9 5mm Pan Head Black 1 Flue Mounting Bracket 1 Installation Instructions DECORATIVE FLUE MOUNTING BRACKETS 2 MOUNTING SCREWS 3 9 x 9 5mm Pan Head 2 MOUNTING SCREWS 3 9 x 9 5mm Pan Head Black FLUE MOUNTING BRACKET 8 MOUNTING SCREWS 8 DRYWALL 4 8 x 38mm Pan Head ANCHORS INSTALL THE DUCTWORK NOTE To reduce the risk of fire use only metal ductwork 1 2 Decide where the ductwork will run between the hood and the outside A straight short duct run will allow the hood to perform most efficiently Long duct runs elbows and transitions will reduce the performance of the hood Use as few of them as possible Install a roof or wall cap Connect 6 round metal ductwork to cap and work back to wards hood location Use duct tape to seal the joints between ductwork sections INSTALL MOUNTING BRA
27. me e DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface causing rust e DO NOT allow salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these com pounds contain chemicals which may be harmful Rinse with water after expo sure and wipe dry with a clean cloth Painted surfaces should be cleaned with warm water and mild detergent only Glass Cleaning Use a soft cloth and a glass cleaning solution only DO NOT use abrasive cloths steel wool or scouring pads DO NOT use strong cleaning solutions or abrasive powders 8 OPERATION LIGHT BLOWER BLOWER SWITCH SPEED SPEED RESET Controls LOWER HIGHEST The hood is operated using the 7 push RE oo t buttons located at eye level on the front of the O O O mm decorative flue e e y i i BLOWER BLOWER TIMED The light switch turns the halogen lights on ON OFF SPEED SHUT and off Push the light switch once to turn the SWITCH HIGHER OFF lights ON push a second time to turn the lights ON to a brighter level push a third time to turn the lights OFF The blower on off switch turns the blower on to its previous running speed The blower must be turned on using this switch Turn the blower off by pressing this switch a second time The blower speed lower switch lowers the blower s running speed This switch works only when the blower is already r
28. ntaje del tubo B03292287 Sujeta cabos B03295008 Caja fusible B08086697 Base para instalaci n el ctrica B02300727 Soporte de cer mica de la l mpara B03292296 Protecci n de la l mpara B02300783 Trasformador B08088323 Conjunto de mandos BE3401651 Pomo interior BE3234559 Tapa BE3342289 Soporte de la l mpara BE3342302 Soporte derecho del cristal BE3342303 Soporte isquierdo del cristal B03295006 Tapa protecci n trasformador B080810285 Accesorios para el montaje B08092518 Conjunto conector del tubo Incluye los N 56 57 B06002019 Conjunto motor Incluye los N 48 49 53 68 69 42 B02300782 Fusible B02300674 Portafusible Se encuentran por separado 31 SERVICE PARTS LISTE PIECES DE RECHANGE LISTA DE PIEZAS DE RECAMBIO NP62000 SERIES RANGE HOOD 111 04307653 1N
29. onctions soient sures et tanches ETRIER CONDUIT _ D CORATIF RUBAN POUR TUYAUTERIE PARA TUYAU ROND EN METAL DE 6 2452 INSTALLATION DU CONDUIT C BLE DES DECORATIF OA NDS 1 Tenez le conduit d coratif pr s du haut de votre hotte Reliez le c ble des commandes de votre hotte au conduit d coratif comme cela est indiqu 2 Faites glisser la section du bas de votre conduit d coratif vers le bas dans les RAINURE rainures de votre hotte SECTION DU 3 Tenez la section du haut de votre conduit ne SECTION DU HAUT DU CONDUIT d coratif et attachez le l trier DECORATIF d assemblage du conduit au moyen des vis qui vous sont fournies 3 9x9 5mm L ETRIER D ASSEM BLAGE DU CONDUIT AU MOYEN DES VIS 246 ENTRETIEN Un bon entretien de votre hotte garantira une excellente performance Filtre anti graisse Nettoyez le filtre anti graisse fr quemment Enlevez le filtre anti graisse en le tirant vers le bas Utilisez une solution d tergente ti de Les filtres anti graisse peuvent tre lav s au lave vaisselle Une fois le filtre anti graisse nettoy proc der comme suit pour son remontage 1 Retirer les ampoules halog nes 2 Remonter le filtre anti graisse 3 Remettre en place les ampoules halog nes Nettoyage de l int rieur de votre hotte DEBRANCHEZ VOTRE HOTTE AVANT DE LA 1 2 Enlevez la grille en m tal en d vissant les NETTOY
30. our vous servir de ce bouton Arr tez le ventilateur en appuyant une deuxi me fois Le bouton vitesse plus basse du ventilateur diminue la vitesse du ventilateur Ce bouton ne fonctionne que si le ventilateur fonctionne d j Le bouton vitesse plus haute du ventilateur augmente la vitesse du ventilateur Ce bouton ne fonctionne que si le ventilateur fonctionne d j Le bouton vitesse plus lev e du ventilateur augmente la vitesse au maxim Ce bouton fonctionne tout moment Le bouton du timer permet que le ventilateur fonctionne de 10 20 minutes avant qu il ne s arr te tout seul Appuyez sur le bouton une fois pour le r gler sur 10 minutes deux fois pour le r gler sur 20 minutes Ce bouton ne fonctionne que si le ventilateur est en marche Le voyant lumineux qui se trouve au dessus du bouton reset s allumera au bout de 30 heures de fonctionnement du ventilateur Cela vous rappelle que vous devez nettoyer le filtre anti graisse Apr s avoir nettoy et remis en place le filtre anti graisse appuyer sur le bouton reset pour teindre le voyant lumineux et faire qu il recommence compter 30 heures HEAT SENTRY Votre hotte est munie d un thermostat HEAT SENTRY Ce thermostat est un dispositif qui actionnera ou augmentera la vitesse du ventilateur s il d tecte une chaleur excessive au dessus de la surface de cuisson 1 Si le ventilateur n est pas en marche il actionnera le ventilateur en haute vitesse 2 Si
31. plied warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE LLC S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE LLC S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE LLC SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNEC TION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty supersedes all prior warranties To qualify for warranty service you must a notify Broan NuTone LLC at the address stated below or telephone 1 800 637 1453 b give the model number and part identification and c describe the nature of any defect in the product or part At the time of requesting warranty service you must present evidence of the original purchase date Broan NuTone LLC 926 West State Street Hartford WI 53027 1 800 637 1453 NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 1 800 543 8687 LISEZ ET CONSERVEZ CES INSTRUCTIONS SEULEMENT POUR UTILISATION DOMESTIQUE A AVERTISSEMENTS POUR REDUIRE LES RISQUES D INCENDIE D
32. quant les caract ristiques de votre hotte pour de plus amples informations et exigences 12 PREPAREZ LA HOTTE Enlever la hotte dans l emballage et controller le contenu Vous devez recevoir 1 Hotte 1 Conduit d coratif 1 Sachet B080810285 avec 2 triers d assemblage 8 Vis d assemblage 4 8 x 38mm T te ronde 8 Chevilles 2 Vis d assemblage 3 9 x 9 5mm T te ronde 2 Vis d assemblage 3 9 x 9 5mm T te ronde Noir 1 trier de support 1 Instructions pour l installation CONDUIT DECORATIVE ETRIERS D ASSEMBLAGE 2 VIS DASSEMBLAGE 3 9 x 9 5mm T te ronde 2 VIS DASSEMBLAGE 3 9 x 9 5mm T te ronde Noir ETRIER DE SUPPORT 8 VIS D ASSEMBLAGE 8 CHEVILLES 4 8 x 38mm T te ronde 248 INSTALLATION DU SYSTEME D EVACUATION REMARQUE Pour r duire les risques d incendie n utilisez que des tuyaux en m tal il 2 D cidez o le tuyau doit tre install entre votre hotte et l ext rieur Un tuyau droit et court permettra votre hotte de fonctionner d une fa on plus efficace Un tuyau long avec des coudes et des transitions r duira le bon fonctionnement de votre hotte En utiliser le moins possible Installez un couvercle sur le toit ou au mur Reliez un tuyau en m tal rond de 6 au couvercle et faites le aller jusqu l emplacement de votre hotte Rendez les jonctions du tuyau herm tiques au moyen d un ruban pour tuyaux INSTALLATION
33. r de la rouille NE PERMETTEZ PAS que des solutions sal es des d sinfectants des blanchissants ou des produits nettoyants restent en contact avec l acier pendant longtemps Beaucoup de ces produits contiennent des produits chimiques qui pourraient causer des dommages Rincez l eau imm diatement s ils entrent en contact et essuyez avec un chiffon humide 17 Les surfaces peintes doivent tre nettoy es avec de l eau ti de additionn e d un d tergent doux seulement Nettoyage du verre Utilisez seulement un chiffon doux et un produit nettoyant pour le verre N UTILISEZ PAS d ponges abrasives de laine d acier ou de produits d graissants N UTILISEZ PAS de solutions nettoyantes fortes ni de poudres abrasives FONCTIONNEMENT LUMIERE VITESSE MAX VITESSE PLUS BASSE Commandes Votre hotte fonctionne gr ce aux 7 boutons 2 2 sur lesquels vous devez appuyer et qui se O O O mm trouvent au niveau de vos yeux sur le devant du conduit d coratif ON OFF VITESSE TIMER Le bouton de la lumi re allume et teint les MOTEUR PLUS lampes halog nes En pressant 1 fois la HAUTE touche la lumi re s allume au 1 niveau en pressant 2 fois la touche la lumi re du 2 niveau s allume clairage plus intense en pressant encore une fois la touche la lumi re s teint Le bouton ON bas OFF du ventilateur fait fonctionner le ventilateur la vitesse qu il avait auparavant Le ventilateur doit tre en marche p
34. so de que ste no pueda ser desacti vado se indicar nel panel de servicio 3 El montaje y la instalaci n el ctrica debe hacerlos un t cnico especializado siguiendo las normas est ndar e incluyendo aquellas de construcci n anti incendio 4 Necesita aire suficiente para una apropiada combusti n y escape de gases a trav s del tubo del dep sito de quema de combustible Para evitar que el humo aspirado vuelva a la cocina siga las directivas del fabricante y las normas est ndar de siguridad as como las normas publicadas por la Asociaci n de prevenci n de incendios NFPA y la Socie dad americana de especialistas en cale facci n refrigeraci n y aire acondicionado y adem s las normas de las autoridades locales Hacer un corte o un taladro en la pared o en el techo no debe da ar la instalaci n el ctrica u otras instalaciones ocultas en la pared Los conductos ventiladores deben siempre desalojar al exterior No use esta unidad con dispositivo de control de la velocidad a estado s lido Para evitar el riesgo de incendio use solamente conductos de metal Esta unidad tiene que ser conectada a tierra O1 ARA EVITAR EL RIESGO DE FUEGO POR ALTO NIVEL DE GRASA Nunca abandone los quemadores con el fuego alto La cocci n causa humo y restos de grasa que pueden arder Caliente el aceite a fuego medio o bajo Encienda siempre la campana cuando cocine a fuego alto o cuando cocine alimentos f cilmente inflamables por
35. st State Street Hartford WI 53027 1 800 637 1453 NuTone Inc 4820 Red Bank Road Cincinnati OH 45227 1 800 543 8687 SERVICE PARTS NP62000 SERIES RANGE HOOD Parts for stainless steel models shown For service parts for black or white models call Broan Customer Service KEY NO PART NO DESCRIPTION B03118083 BE3401653 B020002340 B02300233 B03295005 B02300774 B02300787 B03292357 B03294033 B03295001 B02310184 B03295071 B03204177 BE3334551 BE3403483 B02300206 B02011258 B02011259 B03202430 B03204094 BE3334250 BE3334252 B08091225 BE3400561 BE3334555 B03292287 B03295008 B08086697 B02300727 B03292296 B02300783 B08088323 BE3401651 BE3234559 BE3342289 BE3342302 BE3342303 B03295006 B080810285 B08092518 B06002019 B02300782 B02300674 Not shown assembled Blower Unit Filter Assembly Filter Spring Motor Capacitor Transformer Protection Halogen Lamp Bulb Heat Sentry Wiring Box Wiring Box Cover Filter Support Motor Blower Wheel Rubber Washer Blower Unit Cover Metal Grille Controls Wire Right Blower Housing Left Blower Housing Flue Gasket Glass Gasket Wiring Box Wiring Box Cover Decorative Flue Bottom Decorative Flue Top Flue Mounting Bracket Wire Clamp Fuse Box Control Board Lamp Socket Lamp Shroud Transformer Switch Assembly Back Panel Cover Halogen Bulb Support Right Glass Bracket Left Glass Bracket Transformer Protection Cover Hardwar
36. sujeta con cuatro w tornillos 4 Use un pa o suave y un detergente que no sea fuerte para limpiar la parte interna de la campana 5 Monte el filtro anti grasa 6 Monte las l mparas hal genas Limpieza del exterior de la campana El acero inoxidable es uno de los meteriales m s f ciles de limpiar pero ser a aconsejable un especial cuidado en su uso para mantenerla en buen estado La campana se puede limpiar de las siguientes maneras e Agua caliente con jab n o detergente es la mejor manera para limpiarla e Acl rela con agua corriente s quela con un pa o suave y limpio para evitar las huellas que deja el agua e Para las manchas o restos de grasa que persistan use un producto qu mico dom stico que no raye un limpiador para acero inoxidable con poca agua y un pa o suave e Silas manchas persisten use un estropajo y un cepillo de cerdas suaves con un producto limpiador y agua Frote suavemente en el sentido del pulido o de las vetas del remate del inoxidable No apriete demasiado porque podr a da ar la superficie e No deje que las manchas se acumulen durante mucho tiempo e No use utensilios o cepillos de acero Peque as particulas de acero pueden adherirse y oxidarse e No use soluciones salinas desinfectantes lej as o productos de limpieza que permanezcan en contacto con el acero inoxidable durante largos periodos de tiempo Muchos de estos productos contienen componentes qu micos que podr an res
37. ta dos l mparas N Co SUSTITUCION FUSIBLE DESCONECTAREL APARATO Empuje el tubo decorativo hacia arriba Abrir la caja de la instalacion el ctrica Sustituir por un fusible del mismo tipo 5x20mm 4A 125V Extraiga el filtro antigrasa Extraiga las lamparas tirando de ellas hacia hal genas Tipo MR16 12V 20W Para cambiar las lamparas abajo No trate de sacarlas a rosca Monte el filtro anti grasa Coloque las lamparas metiendo las clavijas de estas en los agujeros y empujando las lamparas hacia arriba FUSIBLE GARANTIA GARANTIA BROAN NUTONE LLC POR UN ANO Broan NuTone LLC garantiza al consumidor comprador de sus productos que dichos productos no tendran defectos en los materiales o fabricaci n durante un periodo de un a o a partir de la fecha de la compra NO HAY OTRO TIPO DE GARANTIAS QUE INCLUYAN O SE LIMITEN EXCLUSIVAMENTE A GARANTIAS IMPLICITAS O DE CAPACIDAD COMERCIAL O CONVE NIENCIA PARA UN PROPOSITO ESPECIFICO Durante el periodo de un a o Broan NuTone LLC si lo estima conveniente reparar o reemplazar sin gastos para el usuario cualquier producto o parte de ste que sea defectuosos habi ndose usado correctamente ESTA GARANTIA NO CUBRE ESTARTER DE NEON NEON LAMPARAS HALOGENAS LAMPARAS DE ILUMINACI N Tampoco cubre el mantenimiento ni los productos o partes de stos que hayan sido usados de forma incorrecta con negligencia rotos accidentalmente o por una incorrecta manuten
38. u des d tergents Evitez d utiliser des aliments pouvant s enflammer sous la Range Hood N utilisez cet appareil que pour une ventilation g n rale Ne l utilisez pas pour vacuer des mati res ou des vapeurs dangereuses ou qui peuvent exploser Pour viter de causer des dommages au moteur et de rendre les rotors bruyants et ou non quilibr s vitez que les sprays pour murs secs la poussi re de construction entrent en contact avec la partie lectrique Le moteur de votre hotte a un thermostat qui teindra automatiquement le moteur s il est surchauff Le moteur se remettra en marche lorsqu il se sera refroidi Si le moteur continue s teindre et se remettre en marche faites v rifier votre hotte Pour mieux capturer les impuret s de cuisine le bas de votre hotte devrait tre une distance minimum de 24 et une distance maximum de 30 au dessus du plan de cuisson Vu que cette hotte est grande et lourde il est recommand de confier l installation de cette hotte deux personnes Ce produit est dot d un thermostat qui active automatiquement le moteur Pour r duire le risque de dommages et viter l activation accidentelle positionner l interrupteur du panneau de service sur la position OFF et bloquer le panneau de service ou mettre un avertissement externe par exemple une plaquette Utiliser uniquement avec un kit de connexion pour alimentation homologu Nous vous recommandons de lire l tiquette indi
39. ultar nocivos Aclare con agua y seque con un pa o limpio Las superficies lacadas deben limpiarse solamente con agua tibia y detergente no muy fuerte 26 Limpieza del cristal Use un pa o suave y un producto limpiacristales solamente No use pa os fuertes esponjas de acero o estropajos No use productos de limpieza fuertes o abrasivos FUNCIONAMIENTO VELOCIDAD LUZ VELOCIDAD TURBO MINIMA RESET Mandos La campana se pone en funcionamiento 000000 utilizando los 7 mandos situados a la altura O O O O mm de los ojos en la parte delantera del tubo decorativo ENCENDIDO TIMER DE El interruptor luz enciende y apaga las APAGADO VELOCIDAD APAGADO l mparas hal genas Pulsando la tecla una ASPIRADOR MAMMA AUTOM TICO vez la luz se enciende a intensidad 1 puls ndolo una segunda vez la luz se enciende a intensidad 2 luz m s intensa y puls ndolo otra vez m s la luz se apaga completamente El mando de encendido m nimo apagado del aspirador pone ste a una velocidad inicial El aspirador se pone en funcionamiento accionando este mando Para apagar el aspirador accione otra vez dicho mando El mando de velocidad m nima del aspirador hace descender la velocidad inicial S lo funciona cuando el aspirador est ya funcionando El mando de velocidad m xima del aspirador aumento la velocidad de ste Este mando s lo funciona cuando el aspirador ya se ha puesto en marcha El mando de velocidad turbo pone
40. unning The blower speed higher switch raises the blower s running speed This switch works only if the blower is already running The blower speed highest switch turns the blower on to its highest running speed This switch works at any time The timed shut off switch allows the blower to run for 10 or 20 minutes before shutting itself off Push the switch once to set for 10 minutes twice to set for 20 minutes This switch works only if the blower is runinng The pilot light above the reset switch will light after the blower has run for 30 hours This is a reminder to clean the grease filter Once the grease filter has been cleaned and replaced push the reset switch to turn out the pilot light and start a new 30 hour count HEAT SENTRY Your hood is equipped with a HEAT SENTRY thermostat This thermostat is a device that will turn on or speed up the blower if it senses excessive heat above the cooking surface 1 If blower is OFF it turns blower ON to HIGH speed 2 If blower is ON at a lower speed setting it turns blower up to HIGH speed When the temperature level drops to normal the blower will return to its original setting WARNING The HEAT SENTRY thermostat can start the blower even if the hood is turned OFF When this occurs it is impossible to turn the blower OFF with its switch If you must stop the blower do it from the main electrical panel HALOGEN BULBS This range hood requires two halogen bulbs Type
41. y Remove the grease filter by pulling it down ward Use a warm detergent solution Grease filters are dishwasher safe After cleaning the grease filter remount as follows 1 Remove the halogen lamps 2 Remount the grease filter 3 Remount the halogen lamps Interior Hood Cleaning DISCONNECT POWER TO HOOD BEFORE CLEANING 1 Remove the grease filter as shown above 2 Remove the light bulbs See HALOGEN BULBS on next page 3 Remove the metal grille held in place with four 4 screws 4 Use a soft cloth and mild detergent solution to wipe interior surfaces clean 5 Remount the grease filter 6 Remount the halogen lamps Exterior Hood Cleaning Stainless steel is one of the easiest materials to keep clean Occasional care will help preserve its fine appearance Cleaning tips e Hot water with soap or detergent is all that is usually needed e Follow all cleaning by rinsing with clear water Wipe dry with a clean soft cloth to avoid water marks e Fordiscolorations or deposits that persist use a non scratching household cleanser or stainless steel polishing powder with a little water and a soft cloth e For stubborn cases use a plastic scouring pad or soft bristle brush together with cleanser and water Rub lightly in direction of polishing lines or grain of the stainless finish Avoid using too much pressure which may mar the surface e DO NOT allow deposits to remain for long periods of ti