Home
NuTone 10N User's Manual
Contents
1. top end of the cabinet Replace cover Fig 2 Nulone OPERATING INSTRUCTION Fig 3 Control Panel AVD45 and AVD50 Series SAFETY SWITCH The Ironing Board depresses this switch when placed in its storage position This disconnects all power to the ironing center controls TIMER Work Lamp Pilot Light and Receptacle are powered ONLY when timer is set Set the amount of time you will be ironing by turning the knob clockwise The timer can be manually turned to 0 Off at any time Turn to 0 Off position when not in use PILOT LIGHT When light is lit it shows that the timer is set and that the power is ON WORK LAMP The lamp will come on when the timer is set A 40 watt max bulb is recom mended ELECTRICAL RECEPTACLE The Ironing Center is equipped with 3 prong grounded receptacle CAUTION Make sure your iron s power cord does not interfere with operation of the SAFETY SWITCH when board is being placed in its storage position CABINET DOOR Fig 4 NOTE Door and fixtures are supplied on AVD4O0WN AVD40KN AVD45WN and AVD45KN Decorative door and fixtures may be purchased separately for AVD4ON AVD45N and AVD50N models See Service Parts List 1 MOUNTING THE CABINET DOOR Door may be hinged from either side of the cabinet Both sides of the cabinet has pre punched holes Use two hinges supplied to fix door to the cabinet Hinges should be placed on top and bottom section of th
2. ER TO AVOID DAMAGE TO THE COVER DO NOT WASH THE COVER The laminated surface of the unit may be wiped clean with non abrasive household cleaner
3. Nulone MODELS AVD4ON AVD40KN AVD40WN AVD45N AVD45KN AVD45WN AVD50N BUILT IN IRONING CENTER Page READ AND SAVE THESE INSTRUCTIONS WARNING A AVD45 and AVD50 Series Only ALL ELECTRICAL WORK MUST BE DONE IN ACCORDANCE WITH LOCAL AND OR NATIONAL ELECTRICAL CODES AS APPLICABLE FOR SAFETY THIS PRODUCT MUST BE GROUNDED IF YOU ARE UNFA MILIAR WITH METHODS OF IN STALLING ELECTRICAL WIRING SE CURE THE SERVICES OF A QUALIFIED ELECTRICIAN The ironing center should be installed on a SEPARATE 15 amp circuit to prevent circuit overload TURN OFF POWER AT SERVICE ENTRANCE BEFORE INSTALLING WIRING OR SERVICING THIS PRODUCT Do not place EXCESSIVE WEIGHT weight should not exceed 30 pounds on the ironing board when opened as it is designed to accept normal ironing use only Allow iron to cool down before storing in the cabinet Empty water reservoir and turn off steam action prior to storing iron Turn power off when not in use Do not remove the board retainer The appliance is supplied with approved components and wires which must not be changed If any components or wires of this equipment is damaged it must only be replaced by the manufacturer service agent or similarly quali fied person in order to avoid hazard 7 This unit may be installed as a surface mount If installed in this manner you MUST USE the Surface Mount Collar Assembly AVDSMN See instruc tions included with Assembly for mounti
4. e cabinet Attach the hinge to cabinet and door using the screws supplied Use the decorative plugs supplied to cover the remaining pre punched holes 2 INSTALLING MAGNETIC CATCH Magnetic catch is attached opposite the hinge Attachment position is located on the top section of the cabinet and the door Attach the magnetic catch 2A onto cabinet using the screws supplied Attach the strike plate 2B onto door using the screw supplied 3 LAMP REPLACEMENT Ensure the power is switched off Timer is on O Off position Insert small screwdriver or slim knife as shown ease catch to side and slip out diffuser Replace lamp 40 watt max Slide diffuser back into aperture and click Into place IRONING BOARD HEIGHT ADJUSTMENT Fig 5 MODEL AVD50N The Ironing Board has three working heights to adjust the board 1 Lower board to the first operating position lowest position 2 Hold the board with one hand NOT BY THE NOSE and support the pivot rod with the other hand 3 Adjust the lroning board to the desired position by lifting the board NOT BY THE NOSE and moving it to the path of height adjust bracket NOTE in order to store the Ironing board it must be on its lowest position MODELS AVD4ON AVD40KN AVD40WN AVD45N AVD45KN AVD45WN AVD50N SAR a a ae tea Sg OE TS a EO RN TE Dae ee Page 2 ELECTRICAL RECEPTACLE MAINTENANCE IRONING CENTER BOARD IS FITTED WITH HEAT RESISTANT COV
5. ng by this method INSTALLATION Fig 1 1 DETERMINE WALL OPENING The NuTone Ironing Centers are designed to fit between standard 16 on cen ter wall studs A 49 1 4 x 14 1 8 x 3 7 8 deep opening is required 24 on center studs will require framing to proper opening size 2 DETERMINE DISTANCE ABOVE THE FLOOR Use the following chart to determine the recommended wall opening above the floor Wall Opening Working Height Above the Floor AVD40 45 Series AVD50 Series k Oomph a7 29 31 33 357 37739 aT aANT 3 ATTACH CLEATS Fasten 2x4 cleats to wall studs to provide a level surface on which to rest cabinet 4 MOUNT CABINET Lift cabinet into place and attach it to studs using the six supplied screws CAUTION DO NOT ALLOW WIRE TO EX Mounting holes positions are indicated by the arrows On AVD45 and AVD50 TEND OUTSIDE OF WIRING BOX EX Series models remove the wireway cover to access mounting hole Be sure to POSED WIRES CAN BECOME PINCHED allow for wall covering thickness behind cabinet face frame Plumb and shim AND ELECTRICAL SHOCK HAZARD MAY cabinet to fit RESULT 5 CONNECT WIRING Fig 2 AVD45 amp AVD50 Series only Remove wireway cover Bring house wiring into cabinet access hole and attach wiring to cabinet with an approved wire strain relief Connect black to black white to white and green bare wire from house wiring to ground fixing terminal at the
Download Pdf Manuals
Related Search
Related Contents
YARDGARD 328402A Instructions / Assembly Manual President Grant II ASC (ENG) Guide Gestion du fait religieux dans l`entreprise vaporetto 2085 V7 L17PS Achat 206 passive full-range speaker user manual 4573-15 PLANILLA COTIZ.x TC 310 - NUSSBAUM France Copyright © All rights reserved.
Failed to retrieve file