Home

Nortel Networks NN46205-310 User's Manual

image

Contents

1. End Variable definition Use the data in the following table to use the password commands access level Allows or blocks this access level The available access levels are I4admin l4oper e layer word layer2 layer3 word oper read only word e read write word Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 64 Configuration read write all word slbadmin slboper ssladmin word represents the new password with 0 to 20 characters aging time 1 365 Sets the age out time for passwords in days default lockout time 60 65 Changes the default lockout time after 000 three invalid attempts Sets the lockout time in seconds and is in the range of 60 to 65 000 The default is 60 seconds To set this option to the default value use the default operator with the command lockout WORD 0 64 time Sets the Host lockout time 60 65000 wordis the Host Internet Protocol IP address in the format a b c d e time is the lockout out time in seconds for passwords from 60 to 65 000 The default is 60 seconds min passwd len 10 20 Sets the minimum length for passwords in high secure mode To set this option to the default value use the default operator with the command password history 3 32 Specifies the number of previous passwords to remember The defaul
2. 2008 Nortel Networks 34 Installation Procedure steps Step Action 1 Use a Phillips screwdriver to loosen the two screws that fasten the filler panel to the chassis 2 Pull the filler panel away from the slot as shown in the following figure 10416FA End Installing an Ethernet Routing Switch 8003 8006 or 8010 chassis into a rack Install an Ethernet Routing Switch 8003 8006 or 8010 chassis in a standard equipment rack 19 inch Prerequisites for installing an Ethernet Routing Switch 8003 8006 or 8010 chassis into a rack Remove any filler panels before you install the chassis to decrease the weight during installation Procedure steps Step Action 1 Hold each rack mounting bracket to the sides of the chassis and align the screw holes Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Installing an Ethernet Routing Switch 8003 8006 or 8010 chassis into a rack 35 9104FA 2 Attach the brackets to the chassis using the supplied Phillips head screws WARNING Risk of personal injury It requires two people to lift a fully loaded chassis To prevent injury keep your back straight and lift with your legs An Ethernet Routing Switch 8010 chassis weighs approximately 101 kg 225 lbs An Ethernet Routing Switch 8006 chassis weighs approximately 77 kg 170 lbs An Ethernet Routing Switch 8003 chassis weighs appr
3. Sets the Layer 4 Administrator logon to connect to the WSM 1 l4oper username Sets the Layer 4 Operator logon to connect to the WSM lockout time lt HostAddress gt Sets the Host lockout time secs HostAddress is the Host IP address in the format a b c d secs is the lockout out time in seconds for passwords from 60 to 65000 The default is 60 seconds Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 62 Configuration min passwd len integer Sets the minimum length for passwords in high secure mode integer is a range from a minimum of 10 to 20 oper username Sets the Operator logon to connect to the WSM password history number Specifies the number of previous passwords to remember number uses a configurable range of 3 to 32 The default is 3 ro username password Changes the read only logon and or password username is the logon name passwordis the password associated with the logon name rw username password Changes the read and write logon name or password or both username is the logon name passwordis the password associated with the logon name rwa username password Changes the read and write all logon name or password or both username is the logon name passwordis the password associated with the logon name slboper username Set
4. This chapter contains configuration instructions for Ethernet Routing Switch 8600 Navigation Connecting a modem using the CLI page 53 Connecting a modem using the NNCLI page 56 Connecting a VT 100 terminal or PC for local access page 58 e Setting system date and time using the CLI page 59 e Setting system date and time using the NNCLI page 59 Changing passwords using the CLI page 22 Changing passwords using the NNCLI page 22 Configuring the system using the setup utility page 65 Connecting a modem using the CLI This section describes how to connect a modem to the modem port on a module You can access the CLI through a modem connection to the Ethernet Routing Switch 8690SF 8691SF CPU or 8692SF CPU modules The modem port is a DTE device is operating at e 9600 baud rate e 8 data bits e no parity e one stop bit ATTENTION Nortel recommends to use the default settings for the Modem port for most modem installations Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 54 Configuration Because the modem port will receive Data Set Ready DSR and Clear To Send CTS signals before transmitting the DSR and CTS control lines are required in the cables The modem port does not support inbound flow control therefore the port does not turn on and off control lines to indicate that the input buffer is full
5. e EMC Electromagnetic Emissions CISPR 22 Class A e EMC Electromagnetic Immunity CISPR 24 e Electrical Safety IEC 60950 with CB member national deviations Further the equipment has been certified as compliant with the national standards as detailed in the following sections National Electromagnetic Compliance EMC Statements of Compliance FCC Statement USA only This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the Federal Communications Commission FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy If it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to take whatever measures may be necessary to correct the interference at their Own expense Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 6 Regulatory Information and Safety Precautions ICES Statement Canada only Canadian Department of Communications Radio Interference Regulations This digital apparatus 8000 Series chassis and installed compo
6. Before connecting a modem to an Ethernet Routing Switch you may need to configure the modem port using another type of CLI connection To configure the modem port using the Ethernet Routing Switch CLI complete the steps in the following procedure Prerequisites You need a DTE to DCE cable straight or transmit cable to connect the Nortel Ethernet Routing Switch 8600 to the modem e You must configure your client dial up settings to establish the connection to the modem Procedure steps Step Action 1 Configure the modem using the following command config bootconfig sio modem Now you can enter options for this command level without retyping the first part of the command 2 Configure port parameters based on the modem requirements baud rate e 8databits true false mode lt ascii slip ppp gt For information about the configuration requirements of your modem see the documentation shipped with the modem ATTENTION Nortel recommends that before you configure SLIP or PPP modes you become familiar with these protocols 3 If you assign the port mode to slip configure the following parameters slip compression true false slip rx compression true false Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Connecting a modem using the CLI 55 0 N OOA If you assign the port mode to ppp configure the following p
7. constitutes a safety hazard 3 If necessary use a heat gun to shrink the tubing around the cable End Installing a breaker interface panel For more information on installing a breaker interface panel BIP see nstalling the Breaker Interface Panel for the 8010co Chassis NN46205 313 Installing a PCMCIA software card Insert the PCMCIA card into the PCMCIA slot of the CPU Starting the system Start the system to run a set of internal self diagnostic tests for all modules Starting the system navigation Turning on AC power supplies page 49 Turning on DC power supplies page 50 LED power supply page 51 Turning on AC power supplies Turn on an Ethernet Routing Switch 8000 Series chassis with an AC power supply Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 50 Installation Procedure steps Step Action 1 Verify the AC power cords are connected to AC power outlets 2 Turn each AC power supply switch to the on position simultaneously Do not operate the 8010co chassis with only one power supply ATTENTION If the chassis contains two or three power supplies turn on the power supplies simultaneously If you wait longer to turn on the second power supply one of the power supplies can turn off within 7 seconds To correct this condition turn off the power supplies for a short period of time and then simultaneously
8. hex wrench on each terminal Attach the earth ground cable to the system or rack ground for the DC input power source Attach the positive and negative terminal leads to the DC input power source according to the safety and technical specifications for your 48 V power distribution system Replace the plastic safety cover on the power supply using a Phillips screwdriver Firmly slide the power supply all the way into the bay Tighten the retaining screws until the power supply is firmly seated Turn the DC input power source on or reset the power source circuit breaker to provide power to the power supply Turn the power supply switch to the on position ATTENTION If the chassis contains two or three non redundant power supplies turn on the power supplies simultaneously If you wait longer to turn on the second power supply one of the power supplies can turn off within 7 seconds To correct this condition turn off the power supplies for a short period of time and then simultaneously turn them on End Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Starting the system 49 Cable preparation Prepare cables for connecting the DC power supply Procedure steps Step Action 1 Strip 0 81 in 2 1 cm of insulation from the ends of the cables 2 Crimp the lugs onto the cables using a standard crimping tool WARNING Failure to properly crimp the lugs onto the cables
9. 2008 Nortel Networks 72 Translation of safety messages WARNING AVVISO Rischio di lesioni personali Sono necessarie due persone per sollevare uno chassis a pieno carico Per evitare lesioni mantenere la schiena dritta e sollevarsi con le gambe Uno chassis Ethernet Routing Switch 8010 pesa circa 101 kg 225 libbre Uno chassis Ethernet Routing Switch 8006 pesa circa 77 kg 170 libbre Uno chassis Ethernet Routing Switch 8003 pesa circa 49 5 kg 110 libbre Preventing electrical shock warning statement WARNING Risk of injury by electric shock To avoid the danger of electrical shock be careful when working with power equipment and connections WARNING AVERTISSEMENT Risques de blessure par choc lectrique Pour pr venir les risques de choc lectrique soyez vigilants lorsque vous manipulez des quipements et des connexions lectriques WARNING WARNUNG Verletzungsrisiko durch Stromschlag Zur Vermeidung eines Stromschlages gehen Sie beim Umgang mit stromf hrenden Ger ten und Anschl ssen sorgf ltig vor WARNING ADVERTENCIA Riesgo de lesiones por choques el ctricos Para evitar choques el ctricos maneje los equipos y conexiones el ctricas con cuidado Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Preventing hand injury warning statement 73 WARNING AVISO Risco de ferimento por choque el trico Para evitar o perigo
10. May 2008 Copyright 2008 Nortel Networks 70 Translation of safety messages WARNING AVISO Risco de ferimento Segure a bandeja do ventilador no meio do painel frontal e tenha cuidado para n o colocar os dedos nas l minas do ventilador WARNING AVVISO Rischio di lesioni personali Afferrare il vassoio del ventilatore nella parte centrale del pannello frontale e prestare attenzione a non toccare le lame Preventing back injury warning statement WARNING Risk of personal injury It requires two people to lift a fully loaded chassis To prevent injury keep your back straight and lift with your legs An Ethernet Routing Switch 8010 chassis weighs approximately 101 kg 225 lbs An Ethernet Routing Switch 8006 chassis weighs approximately 77 kg 170 lbs An Ethernet Routing Switch 8003 chassis weighs approximately 49 5 kg 110 Ibs WARNING AVERTISSEMENT Risques de blessure corporelle Deux personnes sont n cessaires pour soulever un ch ssis rempli Pour viter tout risque de blessure gardez le dos droit et utilisez l appui de vos jambes pour soulever la charge Le ch ssis d un commutateur routeur Ethernet 8010 p se environ 101 kg Le ch ssis d un commutateur routeur Ethernet 8006 p se environ 77 kg Le ch ssis d un commutateur routeur Ethernet 8003 p se environ 49 5 kg Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Preventing
11. Nortel Networks 42 Installation ATTENTION You can install an Ethernet Routing Switch 8600 module with the power on or off Procedure steps Step Action 1 Locate the slot where you want to install the module 2 Remove the power filler panel For instructions see Removing a power filler panel page 33 3 Extend the insert and extract levers away from the front of the module 4 Slide the module into the slot using the module guides until the connector panel touches the chassis back panel 5 Rotate the insert and extract levers to seat the module backplane connectors 6 Tighten the two captive screws to secure the module to the chassis using a Phillips screwdriver See Procedure job aid Installing a module page 43 for installing a module in various chassis 7 After you install the modules you can connect console equipment and network cables End Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Installing AC power modules 43 Procedure job aid Installing a module Figure 2 Installing a module in a 8010co chassis OOOO d KE alia pO ma oa Da ca GG ca ce ei E ZZ LUIGI Den ii sais vivi OOOO MO E ror ed dti tl e ror rir ed od ol irr rar d DODQUDDOOOQUDOOUGUDOOUOOQOOC 20 j gl d 3 Al DI 5 2 ir B g Jul O y EEN C A es V eei eese e s MUS ODIOSO OO U
12. VAC 50 60 Hz 12 6 A maximum for each power supply Model 8005AC 100 120 VAC 50 60 Hz 16 A maximum for each power supply 200 240 VAC 50 60 Hz 8 5 A maximum for each power supply Model 8005DI AC 100 120 VAC 50 60 Hz 16 A maximum for each power supply 200 240 VAC 50 60 Hz 9 3 A maximum for each power supply Model 8004DC 48 60 VDC 29 23 A Model 8005DC 48 60 VDC 42 34 A Informaci n NOM unicamente para M xico La informaci n siguiente se proporciona en el dispositivo o en los dispositivos descritos en este documento en cumplimiento con los requisitos de la Norma Oficial M xicana NOM Exportador Nortel Networks Inc 4655 Great America Parkway Santa Clara CA 95054 USA Importador Nortel Networks de M xico S A de C V Avenida Insurgentes Sur 1605 Piso 30 Oficina Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 10 Regulatory Information and Safety Precautions Tel Fax Embarcar a Col San Jose Insurgentes Deleg Benito Juarez M xico D F 03900 52 5 480 2100 52 5 480 2199 Model 8003AC 100 240 VCA 50 60 Hz 9 A max por fuente de poder Model 8004AC 100 240 VCA 50 60 Hz 12 6 A max por fuente de poder Model 8005AC 100 120 VCA 50 60 Hz 16 A max por fuente de poder 200 240 VCA 50 60 Hz 9 5 A max por fuente de poder Model 8005DI AC 100 120 VCA 50 60 Hz 16 A max por fuente de
13. do choque el trico tenha cuidado ao trabalhar com equipamentos e conex es el tricos WARNING AVVISO Rischio di lesioni per shock elettrico Per evitare il pericolo di shock elettrico prestare attenzione quando si lavora con l alimentatore e i collegamenti WARNING Risk of injury by fan blades When removing the fan module do not put your hands into the opening because of the spinning fan blades in the adjacent fan modules WARNING AVERTISSEMENT Risques de blessure provoqu e par les pales du ventilateur Lorsque vous retirez le module du ventilateur ne mettez pas vos mains dans l ouverture car les pales des modules adjacents en fonctionnement risqueraient de vous blesser WARNING WARNUNG Verletzungsrisiko durch L fter Bl tter Greifen Sie beim Entfernen des L ftungsmoduls wegen der rotierenden Blatter des sich in der Nahe befindlichen L fters nicht in die Offnung Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 74 Translation of safety messages WARNING ADVERTENCIA Riesgo de lesiones por las aspas del ventilador Cuando deba retirar el m dulo del ventilador no coloque las manos en la abertura para evitar accidentes con las aspas de los ventiladores adyacentes WARNING AVISO Risco de ferimento com lamina do ventilador Ao remover o m dulo do ventilador n o coloque as m os na abertura porque existem laminas que giram nos m
14. dulos adjacentes WARNING AVVISO Rischio di lesioni causate dalle lame del ventilatore Quando si rimuove il modulo del ventilatore non inserire le mani nell apertura data la presenza delle lame rotanti del ventilatore nei moduli adiacenti DANGER Risk of injury by electric shock Failure to properly crimp the lugs onto the cables constitutes a safety hazard DANGER DANGER Risques de blessure par choc lectrique Pour votre s curit v rifiez que les cosses sont correctement serties sur les c bles DANGER GEFAHR Verletzungsrisiko durch Stromschlag Es besteht ein Sicherheitsrisiko wenn die Anschlussst cke nicht ordnungsgem auf die Kabel geklemmt werden Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Injury to eye warning statement 75 DANGER PELIGRO Riesgo de lesiones por choques el ctricos Para evitar riesgos pliegue correctamente hacia adentro los terminales de los cables DANGER PERIGO Risco de ferimento por choque el trico Enrolar os suportes aos cabos de maneira incorreta implica em um risco de seguranga WARNING PERICOLO Rischio di lesioni per shock elettrico Il piegamento non corretto delle linguette nei cavi costituisce un rischio per la sicurezza WARNING Risk of eye injury by laser Fiber optic equipment can emit laser or infrared light that can injure your eyes Never look into an optical fiber or c
15. poder 200 240 VCA 50 60 Hz 9 3 A max por fuente de poder Model 8004DC 48 VCD 29A Model 8005DC 48 VCD 42 A Denan Statement Japan Nippon only S ds RBM RER Dron ERT e RT RES E ACTAT Riek BUM UF MRI RE Fc ent CH Nortel Ethernet Routing Switch 8600 Start Quick NN46205 310 02 01 Standard Copyright 2008 Nortel Networks 30 May 2008 Safety Messages 11 Safety Messages This section describes the different precautionary notices used in this document This section also contains precautionary notices that you must read for safe operation of the Nortel Ethernet Routing Switch 8600 Notices Notice paragraphs alert you about issues that require your attention The following sections describe the types of notices For a list of safety messages used in this guide and their translations see Translations of safety messages Attention Notice ATTENTION An attention notice provides important information regarding the installation and operation of Nortel products Caution ESD Notice CAUTION ESD ESD notices provide information about how to avoid discharge of static electricity and subsequent damage to Nortel products CAUTION ESD d charge lectrostatique La mention ESD fournit des informations sur les moyens de pr venir une d charge lectrostatique et d viter d endommager les produits Nortel CAUTION ACHTUNG ESD ESD Hinweise bieten Information dazu wie man d
16. und die mit Stromkreisen verbundenen Gefahren bevor Sie mit diesem Ger t arbeiten Verwenden Sie nur Netzkabel mit Erdungspfad Stellen Sie sicher dass der Schalter ordnungsgemaB geerdet ist bevor Sie das Ger t einschalten DANGER PELIGRO Riesgo de lesi n por electrocuci n Antes de trabajar con este equipo inf rmese acerca de las medidas de seguridad adecuadas y de los peligros relacionados con los circuitos el ctricos Utilice s lo cables de corriente que tengan puesta a tierra Aseg rese de que el interruptor tenga puesta a tierra antes de encender la unidad Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 78 Translation of safety messages DANGER PERIGO Risco de ferimentos por choque el trico Antes de comecar a trabalhar com o equipamento esteja ciente das pr ticas de seguran a adequadas e dos perigos inerentes a circuitos el tricos Use apenas cabos de alimenta o que tenham liga o terra Certifique se de que o switch esteja devidamente aterrado antes de ligar o aparelho DANGER PERICOLO Rischio di scosse elettriche Prima di utilizzare questa apparecchiatura considerare le appropriate pratiche di sicurezza e i pericoli correlati ai circuiti elettrici Utilizzare esclusivamente cavi di alimentazione dotati di un percorso per il collegamento a terra Prima di attivare l alimentazione dell unit accertarsi che l interr
17. 0 02 01 Start Standard 30 May 2008 Copyright 2008 Nortel Networks Do you want to enable CPU High Availability mode n y n Do you want to enable vlan optimization mode support n y n Do you want to enable r mode support n y n Do you want to enable FTP n y n Do you want to enable RLOGIN n y n Do you want to enable TELNET n y n Do you want to enable TFTP n y n Do you want to enable WEB server service n y n IP Address for mgmt port in first CPU Slot 192 168 168 168 255 255 255 0 IP Address for mgmt port in second CPU Slot 192 168 168 169 255 255 255 0 IP Address for mgmt virtual ip 0 0 0 0 0 0 0 0 Configuring the system using the setup utility 67 Specify y if you want to enable CPU high availability HA mode Accept the default n if you do not want to enable CPU HA mode Specify y if you want to enable vlan optimization mode support Accept the default n if you do not want to enable vlan optimization mode support Specify y if you want to enable r mode support Accept the default n if you do not want to enable r mode support Enter y if you want to enable FTP for remote users Accept the default n if you do not want to enable FTP Enter y if you want to enable Rlogin for remote users Press Enter to accept the default n if you do not want to enable Rlogin Enter y if you want to enable Telnet Press Enter to acce
18. 5 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 26 Installation preparation The 8003 chassis provides two slots for installing Ethernet Routing Switch 8600 interface modules and one slot for installing an Ethernet Routing Switch 8691 CPU Module Slots are numbered from top to bottom DC power supply accessories The DC power supply shipment contains hardware accessories Use the following checklist to verify the contents of the 8004DC shipping container Table 1 8004DC power supply shipping accessories check Iesse pu Two 2 hole crimp Connect the positive lug terminals with and negative power attached tubing inputs 8004 One 1 hole crimp Connect the ground lug terminal with e stud attached tubing ES 5 lock washers Po Connect all leads 1 washer Connect the ground stud Use the following checklist to verify the contents of the 8005DC shipping container Table 2 8005DC power supply shipping accessories check Iesse Jun Three 2 hole crimp Connect the positive lug terminals with Lege mm and negative power attached tubing inputs Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Safety precautions 27 check Accessory J Kc 6 nuts Connect all leads 6 lock washers Po Connect all leads 2 washers Connect the ground stud Safety precautions This section describes the safety precautions whic
19. NORTEL Quick Start Release 5 0 Document Revision 02 01 www nortel com NN46205 310 321749 B Rev 01 Nortel Ethernet Routing Switch 8600 Release 5 0 Publication NN46205 310 Document status Standard Document release date 30 May 2008 Copyright 2008 Nortel Networks All Rights Reserved Printed in Canada India and the United States of America LEGAL NOTICE While the information in this document is believed to be accurate and reliable except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT AS IS WITHOUT WARRANTY OR CONDITION OF ANY KIND EITHER EXPRESS OR IMPLIED The information and or products described in this document are subject to change without notice Nortel the Nortel logo the Globemark and Passport are trademarks of Nortel Networks All other trademarks are the property of their respective owners ATTENTION For information about the regulatory and safety precautions read Regulatory messages and safety precautions in this guide For information about the software license read Software license in this guide For a list of safety messages used in this guide and their translations see Translations of safety messages Contents Regulatory Information and Safety Precautions 5 Software license 17 New in this release 21 Features 21 Other changes 21 Connecting the modem using the CLI 22 Connecting the modem using the NNCLI 22 Setting the system d
20. OR IMPLIED The information and or products described in this document are subject to change without notice Nortel the Nortel logo the Globemark and Passport are trademarks of Nortel Networks All other trademarks are the property of their respective owners ATTENTION For information about the regulatory and safety precautions read Regulatory messages and safety precautions in this guide For information about the software license read Software license in this guide For a list of safety messages used in this guide and their translations see Translations of safety messages NORTEL
21. Push the sides of the top cable management bracket into place Insert and tighten the eight screws using a Phillips screwdriver to secure the top cable management bracket to the chassis End Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Installing the side cable management brackets 39 Procedure job aid Installing the cable management brackets m gt d le note r nj EON 3 CH w DIAE 8 g B B g Li o W H ALD d AL mE 114 AE gd et Qi CN Installing the side cable management brackets Install the side cable management brackets to each side of the 8010co chassis Procedure steps Step Action 1 Align the slots on the side cable management bracket with the rods in the chassis 2 Push the bracket into place For more information see Procedure job aid Installing the cable management brackets page 39 End Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 40 Installation Grounding the 8010co chassis Ground the 8010co chassis to avoid electrical hazard and ensure optimal performance ATTENTION Nortel recommends grounding the 8010co chassis before you connect power cables or network cables to your switch Prerequisites Verify that you have the following tools and materials One single hole cable l
22. RS 8606 5 Setting system date and time using the NNCLI Set the system date and time using the NNCLI Prerequisites You must log on to the privExec mode Procedure steps Action Set the system date by using the following command clock set lt MMddyyyyhhmmss gt Procedure job aid clock set command output The following is a sample output to verify the clock set command Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 60 Configuration ERS 86108 5itclock set lt MMddyyyyhhmmss gt MMddyyyyhhmmss ERS 8616 5 clock set 09202007172000 local time THU SEP 26 17 20 00 2007 UTC utc time THU SEP 20 17 26 66 2007 UTC ERS 8610 5 _ Changing passwords using the CLI Set new passwords for each access level or change the logon password for the different switch access The Ethernet Routing Switch Switch 8600 ships with default passwords configured for CLI access When you use Simple Network Management Protocol version 3 SNMPv3 you can change passwords that are in an encrypted format Prerequisites You must have read write all privileges to change passwords Passwords are saved to a hidden file to maintain security The password associated with the user name or logon name is the optional password parameter Procedure steps Action Change a password by using the following command config cli password Variable definitions Use the data
23. Software require Nortel Networks to include additional or different terms Customer agrees to abide by such terms provided by Nortel Networks with respect to such third party software 2 Warranty Except as may be otherwise expressly agreed to in writing between Nortel Networks and Customer Software is provided AS IS without any warranties conditions of any kind NORTEL NETWORKS DISCLAIMS ALL WARRANTIES CONDITIONS FOR THE SOFTWARE EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND ANY WARRANTY OF NON INFRINGEMENT Nortel Networks is not obligated to provide support of any kind for the Software Some jurisdictions do not allow exclusion of implied warranties and in such event the above exclusions may not apply 3 Limitation of Remedies IN NO EVENT SHALL NORTEL NETWORKS OR ITS AGENTS OR SUPPLIERS BE LIABLE FOR ANY OF THE FOLLOWING a DAMAGES BASED ON ANY THIRD PARTY CLAIM b LOSS OF OR DAMAGE TO CUSTOMER S RECORDS FILES OR DATA OR c DIRECT INDIRECT SPECIAL INCIDENTAL PUNITIVE OR CONSEQUENTIAL DAMAGES INCLUDING LOST PROFITS OR SAVINGS WHETHER IN CONTRACT TORT OR OTHERWISE INCLUDING NEGLIGENCE ARISING OUT OF YOUR USE OF THE SOFTWARE EVEN IF NORTEL NETWORKS ITS AGENTS OR SUPPLIERS HAVE BEEN ADVISED OF THEIR POSSIBILITY The forgoing limitations of remedies also apply to any developer and or supplier of the Software Such develo
24. TA oh We Ah M M d 00 00 00 00 00 eo 00 na Af M 10275FA Figure 3 Installing a module in a 8003 8006 and 8010 chassis 102S0FA Installing AC power modules Install AC power modules in the left most bay to supply AC power to the chassis ATTENTION The 8006 8010 and 8010co chassis have three power supply bays that are numbered 1 2 and 3 from left to right as viewed from the front of the chassis The 8003 chassis has 2 power supply bays that are numbered 1 and 2 from left to right Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 44 Installation Prerequisites Ensure the filler panel or cover from the power bay is removed To remove the filler panel see Removing a power filler panel page 33 Procedure steps Step Action 1 Grasp the handle of the new power supply and push the power supply firmly into the bay 2 Tighten the retaining screws until the power supply is firmly seated 3 Connect the power cord to the power supply and to an AC power outlet that is connected to a circuit with no other equipment connections End Installing DC power modules Install the DC power supply module in the leftmost bay to supply DC power to the chassis ATTENTION The 8006 and 8010 chassis have three power supply bays that are numbered 1 2 and 3 from left to right as viewed from the front of the chassis Prerequisi
25. VT 100 terminal or PC for local access 58 Setting system date and time using the CLI 59 Procedure job aid config setdate command sample output 59 Setting system date and time using the NNCLI 59 Procedure job aid clock set command output 59 Changing passwords using the CLI 60 Changing passwords using the NNCLI 63 Configuring the system using the setup utility 65 Procedure job aid Setup Utility prompt descriptions 66 Translation of safety messages 69 Fan tray safety warning message 69 Preventing back injury warning statement 70 Preventing electrical shock warning statement 72 Preventing hand injury warning statement 73 Safety danger statement 74 Injury to eye warning statement 75 Safety practices and the hazards danger statement 77 Safety practices and the hazards danger statement 78 Preventing electric shock danger statement 80 Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Regulatory Information and Safety Precautions Read the information in this section to learn about regulatory conformities and compliances International Regulatory Statements of Conformity This is to certify that the Nortel 8000 Series chassis and components installed within the chassis were evaluated to the international regulatory standards for electromagnetic compliance EMC and safety and were found to have met the requirements for the following international standards
26. accept a default route of 0 0 0 0 Enter the IP address of the third network management route static route from the network management port to a device in the network Enter an IP address of the fourth network management route static route from the network management port to a device in the network Enter the IP address of the default virtual LAN VLAN Enter y to save the boot and runtime configuration files Press Enter n if you do not want to save your changes Nortel Ethernet Routing Switch 8600 Copyright 2008 Nortel Networks Quick Start NN46205 310 02 01 30 May 2008 Standard 69 Translation of safety messages Fan tray safety warning message WARNING Risk of personal injury Grasp the fan tray at the middle of the front panel and be careful to keep your fingers out of the fan blades WARNING AVERTISSEMENT Risques de blessure corporelle Saisissez le boitier du ventilateur au milieu du panneau avant en veillant maintenir vos doigts loign s des pales WARNING WARNUNG Verletzungsrisiko Greifen Sie das Geh use des L fters vorne in der Mitte und achten Sie darauf dass Ihre Finger nicht zwischen die Bl tter des L fters geraten WARNING ADVERTENCIA Riesgo de lesiones Sostenga la bandeja del ventilador en la mitad del panel delantero y tenga cuidado de mantener los dedos alejados de las aspas Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30
27. arameters mtu bytes my ip lt ipaddr gt peer ip lt ipaddr gt pppfile file Turn off echo mode and return code messaging on the modem Connect the modem to the modem port Save the boot configuration Reboot the switch End Variable definitions 8databits true false Specifies either 8 true or 7 false data bits for each byte for software to interpret The default is false baud rate Sets the baud rate for the modem The default is 9600 enable true false True sets the value to 7 False sets the value to 8 This setting is default Sets the default setting This setting is recommended for most modem connections Sets the port for serial line IP SLIP operation PPP operation LENT Sets the port for point to point protocol slip compression Enables or disables the TCP IP header true false compression The default is false slip rx compression Enables or disables the TCP IP header true false compression on the receive packet The default is false mtu bytes Sets the maximum transmission unit for the di e IDE link 0 2048 The default is zero my ip ipaddr Sets the near end IP address on the point to point link The default is 0 0 0 0 Copyright 2008 Nortel Networks Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 56 Configuration peer ip lt ipaddr gt Sets the peer IP address on the point
28. ate and time using the CLI 22 Setting the system date and time using the NNCLI 22 Changing passwords using the CLI 22 Changing passwords using the NNCLI 22 Introduction 23 Installation preparation 25 Ethernet Routing Switch 8600 slots 25 DC power supply accessories 26 Safety precautions 27 Personal safety 27 Installation 31 Unpacking the chassis 32 Removing a power filler panel 33 Installing an Ethernet Routing Switch 8003 8006 or 8010 chassis into a rack 34 Installing the 8010co chassis in a 19 inch two post rack 36 Installing the 8003 8006 and 8010 chassis cable guides 37 Installing the top cable management bracket 38 Procedure job aid Installing the cable management brackets 39 Installing the side cable management brackets 39 Grounding the 8010co chassis 40 Procedure job aid Grounding the 8010co chassis 41 Installing a module 41 Procedure job aid Installing a module 43 Installing AC power modules 43 Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Installing DC power modules 44 Cable preparation 49 Installing a breaker interface panel 49 Installing a PCMCIA software card 49 Starting the system 49 Turning on AC power supplies 49 Turning on DC power supplies 50 LED power supply 51 Verifying a successful installation 51 Configuration 53 Connecting a modem using the CLI 53 Connecting a modem using the NNCLI 56 Connecting a
29. ation about the configuration requirements of your modem see the documentation shipped with the modem ATTENTION Nortel recommends that before you configure Serial Line IP SLIP or PPP you become familiar with these protocols 2 If you assign the port mode to slip use the following command to configure other slip parameters boot config sio modem slip compression slip rx compression 3 If you assign the port mode to ppp use the following commands to configure other ppp parameters boot config sio modem mtu lt bytes gt my ip lt ipaddr gt peer ip lt ipaddr gt pppfile lt file gt Turn off echo mode and return code messaging on the modem Connect the modem to the modem port Save the boot configuration zl oO A Optionally shutdown and reinitialize the port by using the following command boot config sio modem restart 8 Reboot the switch End Variable definitions 8databits Set number of data bits per byte for software to interpret mtu Sets point to point link maximum transmission unit Sets my IP address on point to point link Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 58 Configuration Set peer IP address on point to point link pppfile Use the file for PPP initialization parameters Shutdown and re initialize the port Enable TCP IP header compression slip rx compression Enable re
30. aws and regulations 4 Neither party may bring an action regardless of form more than two years after the cause of the action arose 5 The terms and conditions of this License Agreement form the complete and exclusive agreement between Customer and Nortel Networks 6 This License Agreement is governed by the laws of the country in which Customer acquires the Software If the Software is acquired in the United States then this License Agreement is governed by the laws of the state of New York Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Jting Switch 8600 Standard 8 Copyright 2008 Nortel Networks 21 New in this release The following sections detail what s new in Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 for Release 5 0 Features page 21 e Other changes page 21 Features See the following sections for information about changes that are feature related Nortel Command Line Interface page 21 Nortel Command Line Interface The Nortel Ethernet Routing Switch 8600 uses the Nortel Networks Command Line Interface NNCLI This document provides configuration instructions for existing features using the NNCLI Other changes See the following sections for information about the changes that are not feature related Connecting the modem using the CLI page 22 Connecting the modem us
31. back injury warning statement 71 WARNING WARNUNG Verletzungsrisiko Es sind 2 Personen notwendig um ein voll besetztes Chassis anzuheben Zur Vermeidung von Verletzungen halten Sie beim Heben Ihren R cken gerade und heben Sie das Gewicht aus den Beinen heraus Das Chassis des Ethernet Routing Switch 8010 wiegt ungefahr 101 kg 225 lbs Das Chassis des Ethernet Routing Switch 8006 wiegt ungefahr 77 kg 170 lbs Das Chassis des Ethernet Routing Switch 8003 wiegt ungefahr 49 5 kg 110 lbs WARNING ADVERTENCIA Riesgo de lesiones Se necesitan dos personas para levantar un chasis completamente cargado Para evitar lesiones mantenga la espalda recta y realice la fuerza con las piernas El chasis de Ethernet Routing Switch 8010 pesa aproximadamente 101 kg 225 Ib El chasis de Ethernet Routing Switch 8006 pesa aproximadamente 77 kg 170 Ib El chasis de Ethernet Routing Switch 8003 pesa aproximadamente 49 5 kg 110 Ib WARNING AVISO Risco de ferimento Para erguer um chassi totalmente carregado sao necessarias duas pessoas Para evitar ferimentos mantenha sua coluna reta e erga suas pernas Um chassi Ethernet Routing Switch 8010 pesa aproximadamente 101 kg 225 lbs Um chassi Ethernet Routing Switch 8006 pesa aproximadamente 77 kg 170 Ibs Um chassi Ethernet Routing Switch 8003 pesa aproximadamente 49 5 kg 110 lbs Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright
32. ceive packet TCP IP header compression Sets my IP address on point to point link Procedure job aid DTE to DCE straight through pin assignments Table 4 DTE to DCE straight through pin assignments DCE DB 9 DCE DB 25 I CPE number p number Connecting a VT 100 terminal or PC for local access Connect a VT 100 terminal or a personal computer to the console port on a 8691SF CPU or 8692SF CPU module to establish a local CLI NNCLI or Device Manager session Prerequisites Aserial console cable with a nine pin receptable connector Procedure steps Step Action 1 Connect an RS 232 cable to the console port on an 8691SF CPU or 8692SF CPU module 2 Connect the other end of the RS 232 cable to a VT 100 terminal or PC serial port Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Setting system date and time using the NNCLI 59 3 Turn on the terminal or PC 4 Log on to the CLI End Setting system date and time using the CLI Set the system date and time using the CLI Procedure steps Action Set the date of the system by using the following command config setdate lt MMddyyyyhhmmss gt Procedure job aid config setdate command sample output The following is a sample output to verify the config setdate command ERS 8606 5 config setdate 06062002191200 local time THU JUN 06 19 12 00 2002 UTC utc time THU JUN 06 19 12 00 2002 UTC E
33. checklist of the shipped accessories Navigation Ethernet Routing Switch 8600 slots page 25 DC power supply accessories page 26 e Safety precautions page 27 Ethernet Routing Switch 8600 slots The Ethernet Routing Switch 8010co chassis provides eight slots for installing Ethernet Routing Switch 8600 interface modules and two slots for installing the Ethernet Routing Switch 8691SF CPU and 8692SF CPU switch fabric modules Slots are numbered from left to right Install Ethernet Routing Switch 8600 interface modules in slots 1 to 4 and 7 to10 Slots 5 and 6 are reserved for Ethernet Routing Switch 8600 Series SF CPU modules The 8010 chassis provides eight slots for installing Ethernet Routing Switch 8600 interface modules and two slots for installing Ethernet Routing Switch 8691SF CPU or 8692SF CPU modules Slots are numbered from top to bottom Install Ethernet Routing Switch 8600 interface modules in slots 1 to 4 and 7 to 10 Slots 5 and 6 are reserved for Ethernet Routing Switch 8600 SF CPU modules The 8006 chassis provides four slots for installing Ethernet Routing Switch 8600 interface modules and two slots for installing Ethernet Routing Switch 8691SF CPU or 8692SF CPU modules Slots are numbered from top to bottom Install Ethernet Routing Switch 8600 interface modules in slots 1 to 4 Slots 5 and 6 are reserved for Ethernet Routing Switch 8600 SF CPU modules Nortel Ethernet Routing Switch 8600 Quick Start NN4620
34. decuadas y de los peligros relacionados con los circuitos el ctricos Utilice s lo cables de corriente que tengan puesta a tierra Aseg rese de que el interruptor tenga puesta a tierra antes de encender la unidad DANGER PERIGO Risco de ferimentos por choque el trico Antes de comegar a trabalhar com o equipamento esteja ciente das pr ticas de seguranca adequadas e dos perigos inerentes a circuitos el tricos Use apenas cabos de alimenta o que tenham liga o terra Certifique se de que o switch esteja devidamente aterrado antes de ligar o aparelho DANGER PERICOLO PERICOLO Rischio di scosse elettriche Prima di utilizzare questa apparecchiatura considerare le appropriate pratiche di sicurezza e i pericoli correlati ai circuiti elettrici Utilizzare esclusivamente cavi di alimentazione dotati di un percorso per il collegamento a terra Prima di attivare l alimentazione dell unit accertarsi che l interruttore sia adeguatamente collegato alla messa a terra Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 80 Translation of safety messages Preventing electric shock danger statement Copyright 2008 Nortel Networks DANGER Risk of injury by electric shock Before you continue with this procedure ensure that the DC power source is switched off DANGER Risques de blessure par choc lectrique Avant de poursuivre cette proc dure a
35. eries chassis complies with the requirements of EN 300386 V1 3 3 for emissions and for immunity for a Class A device intended for use in either Telecommunications centre or locations other than telecommunications centres given the performance criteria as specified by the manufacturer EC Declaration of Conformity This product conforms to the provisions of the R amp TTE Directive 1999 5 EC Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks National Electromagnetic Compliance EMC Statements of Compliance 7 European Union and European Free Trade Association EFTA Notice All products labeled with the CE marking comply with R amp TTE Directive E E 1999 5 EEC which includes the Electromagnetic Compliance EMC Directive 2004 108 EC and the Low Voltage Directive 2006 95 EC issued by the Commission of the European Community Compliance with these directives implies conformity to the following European Norms ENs The equivalent international standards are listed in parenthesis EN 55022 CISPR 22 Electromagnetic Interference EN 55024 IEC 61000 4 2 3 4 5 6 8 11 Electromagnetic Immunity e EN 61000 3 2 IEC 610000 3 2 Power Line Harmonics EN 61000 3 3 IEC 610000 3 3 Power Line Flicker VCCI Statement Japan Nippon only This is a Class A product based on the standard of the Voluntary Control Council for Interference VCCI for informat
36. f the runtime image resides on a PCMCIA card you must specify the path for example pcmcia filename Press Enter to accept the default Ethernet Routing Switch 8606 or enter a different string of up to 20 characters Press Enter to accept the default 5 or specify 6 for the master CPU slot Press Enter to accept the default n or enter y to indicate that you want the master CPU management port to use autonegotiation Press Enter to accept the default 10 Mbps or specify 100 Mbps Press Enter y if you want the boot and runtime configuration files to be saved on the backup CPU Press Enter to accept the default n if you want the boot and runtime configuration files to be saved only on the primary CPU Press Enter y if you want the chassis to run in 128 K or M mode Press Enter to accept the default n if you want it to run in 32 K mode only To run in 128 K mode the CPU module must be an 8691 or higher and the switch must have at least one 8600 module 128 K module If you enable m mode support and you have a mixed configuration of modules the E modules and classic modules are disabled Enter y if you want to enable enhanced operation mode Accept the default n if you do not want to enable enhanced operation mode If you enable enhanced operation mode and you have a mixed configuration of modules the classic modules E or M modules are disabled Nortel Ethernet Routing Switch 8600 Quick NN46205 31
37. h are vital for handling and installing the Ethernet Routing Switch 8600 Safety precautions navigation Personal safety page 27 Module safety page 28 Cable and connector safety page 28 e Electrostatic discharge safety page 29 Personal safety For your safety review the following personal safety warnings before working with the Ethernet Routing Switch 8600 DANGER Risk of injury by fan blades When removing the fan module do not put your hands into the opening because of the spinning fan blades in the adjacent fan modules WARNING Risk of personal injury Grasp the fan tray at the middle of the front panel and be careful to keep your fingers out of the fan blades DANGER Risk of injury by electric shock The electrical connector at the rear of the slot poses a risk of electrical shock Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 28 Installation preparation WARNING Risk of eye injury by laser Fiber optic equipment can emit laser or infrared light that can injure your eyes Never look into an optical fiber or connector port Always assume that fiber optic cables are connected to a light source Module safety Use the following general practices to prevent the equipment damage when working with the Ethernet Routing Switch 8600 Always wear an antistatic wrist strap that is connected to an Electrostatic discha
38. ie Entladung von statischer Elektrizitat und Folgeschaden an Nortel Produkten verhindert CAUTION PRECAUCION ESD Descarga electrost tica El aviso de ESD brinda informaci n acerca de c mo evitar una descarga de electricidad est tica y el da o posterior a los productos Nortel CAUTION CUIDADO ESD Os avisos do ESD oferecem informac es sobre como evitar descarga de eletricidade est tica e os conseq entes danos aos produtos da Nortel Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 12 Regulatory Information and Safety Precautions CAUTION ATTENZIONE ESD Le indicazioni ESD forniscono informazioni per evitare scariche di elettricit statica e i danni correlati per i prodotti Nortel Caution Notice CAUTION Caution notices provide information about how to avoid possible service disruption or damage to Nortel products CAUTION ATTENTION La mention Attention fournit des informations sur les moyens de pr venir une perturbation possible du service et d viter d endommager les produits Nortel CAUTION ACHTUNG Achtungshinweise bieten Informationen dazu wie man m gliche Dienstunterbrechungen oder Sch den an Nortel Produkten verhindert CAUTION PRECAUCION Los avisos de Precauci n brindan informaci n acerca de c mo evitar posibles interrupciones del servicio o el dafo a los productos Nortel CAUTION CUIDADO Os aviso
39. ify that the Nortel 8000 Series chassis and components installed within the chassis are in compliance with the requirements of EN 60 950 in accordance with the Low Voltage Directive Additional national differences for all European Union countries have been evaluated for compliance Some components installed within the 8000 Series chassis may use a nickel metal hydride NiMH and or lithium ion battery The NiMH and lithium ion batteries are long life batteries and it is very possible that you will never need to replace them However should you need to replace them refer to the individual component manual for directions on replacement and disposal of the battery NOM Statement 8010 8006 and 8003 Chassis Mexico only The following information is provided on the devices described in this document in compliance with the safety requirements of the Norma Oficial M xicana NOM Exporter Nortel Networks Inc 4655 Great America Parkway Santa Clara CA 95054 USA Importer Nortel Networks de M xico S A de C V Avenida Insurgentes Sur 1605 Piso 30 Oficina Col San Jose Insurgentes Deleg Benito Juarez Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks National Safety Statements of Compliance 9 M xico D F 03900 Tel 52 5 480 2100 Fax 52 5 480 2199 Input Model 8003AC 100 240 VAC 50 60 Hz 9 A maximum for each power supply Model 8004AC 100 240
40. in the following table to use the config cli password command access level access level Allows or blocks this access level lt enable disable gt access level is an integer from 2 to 8 enable disable enables or disables the chosen access level aging days Sets the password age out time days is the number of days until the password expires from 1 to 365 Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Changing passwords using the CLI 61 default lockout time secs Changes the default lockout time after three invalid attempts secsis the lockout time in seconds from 60 to 6500 The default is 60 seconds info Shows the current level parameter settings and the next level directories 11 username password Changes the Layer 1 read and write logon name or password or both username is the logon name passwordis the password associated with the logon name 12 username password Changes the Layer 2 read and write logon name or password or both username is the logon name passwordis the password associated with the logon name 13 username password Changes the Layer 3 read and write logon name or password or both applies only to the Ethernet Routing Switch 8600 username is the logon name passwordis the password associated with the logon name l4admin username
41. ing the NNCLI page 22 e Setting the system date and time using the CLI page 22 e Setting the system date and time using the NNCLI page 22 Changing passwords using the CLI page 22 Changing passwords using the NNCLI page 22 Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 22 New in this release Connecting the modem using the CLI This section describes how to connect a modem to the modem port on an SF CPU module using the CLI command You can access the CLI through a modem connection to the Ethernet Routing Switch 8690SF 8691SF CPU or 8692SF CPU modules For more information see Connecting a modem using the CLI page 53 Connecting the modem using the NNCLI This section describes how to connect a modem to the modem port on an SF CPU module using the NNCLI command You can access the NNCLI through a modem connection to the Ethernet Routing Switch 8690SF 8691SF CPU or 8692SF CPU modules For more information see Connecting a modem using the NNCLI page 56 Setting the system date and time using the CLI This section describes the instructions to set the system date and time using the CLI For more information see Setting system date and time using the CLI page 59 Setting the system date and time using the NNCLI This section describes the instructions to set the system date and time using the NNCLI For more infor
42. ion technology equipment If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions CORES HHLRKESCRRSAEMHNBRS VCCI OXX ESC VIAZAMMRHERCT TOHE SXIERRCIERT S cq DREESIAETICENDNES oSRelcut mmti sss m 5k5NR nscthkbuti BSMI Statement for 8010 8006 and 8003 Chassis Taiwan only This is a Class A product based on the standard of the Bureau of Standards Metrology and Inspection BSMI CNS 13438 Class A ub jee PRIVE i gt TERR CERTOS HRS HIS TRE SORS DU ZR FR HER TF AEREOS ESE MIC Notice for 8010 8006 8003 Chassis Republic of Korea only This device has been approved for use in Business applications only per the Class A requirements of the Republic of Korea Ministry of Information and Communications MIC This device may not be sold for use in a non business application Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 8 Regulatory Information and Safety Precautions Ven Ore Ore Ore Ore Orr Orr en ee See Gre dee Ore Ore Orr Ore Orr SE Sa Y Switch Passport 2600 ECtt 02 0015 A seet Nortel Netwarks Ltd HTA Za 2 Nortel Networks Ltd Bl Acum por 9 SAP 807 N97 SAP 8809 N97 SNP SH ge SHIP SNP ie E ge e National Safety Statements of Compliance CE Marking Statement Europe only EN 60 950 Statement This is to cert
43. mation see Setting system date and time using the NNCLI page 59 Changing passwords using the CLI This section describes the instructions to set new passwords for each access level or change the logon password for the different switch access using the CLI For more information see Connecting a modem using the CLI page 53 Changing passwords using the NNCLI This section describes the instructions to set new passwords for each access level or change the logon password for the different switch access using the NNCLI For more information see Changing passwords using the NNCLI page 63 Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 23 Introduction The Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 provides basic instructions about installing the hardware and performing basic configuration of the Ethernet Routing Switch 8010 8006 8003 and 8010co chassis and software Navigation Installation preparation page 25 Installation page 31 e Configuration page 53 Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 24 Jting Switch 8600 Standard 8 Copyright 2008 Nortel Networks 25 Installation preparation This section provides basic information about the Ethernet Routing Switch 8600 slots It also include a
44. nents does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications R glement sur le brouillage radio lectrique du minist re des Communications Cet appareil num rique 8000 Series chassis respecte les limites de bruits radio lectriques visant les appareils num riques de classe A prescrites dans le R glement sur le brouillage radio lectrique du minist re des Communications du Canada CE Marking Statement Europe only EN 55 022 Statements This is to certify that the Nortel 8000 Series chassis and components installed within the chassis are shielded against the generation of radio interference in accordance with the application of Council Directive 2004 108 EC Conformity is declared by the application of EN 55 022 Class A CISPR 22 CAUTION This device is a Class A product Operation of this equipment in a residential area is likely to cause harmful interference in which case users are required to take appropriate measures necessary to correct the interference at their own expense EN 55 024 Statement This is to certify that the Nortel 8000 Series chassis is shielded against the susceptibility to radio interference in accordance with the application of Council Directive 2004 108 EC Conformity is declared by the application of EN 55 024 CISPR 24 EN 300386 Statement The Ethernet Routing Switch 8000 S
45. onnector port Always assume that fiber optic cables are connected to a light source WARNING AVERTISSEMENT Risques de blessure oculaire par lumi re laser L quipement de fibres optiques peut mettre une lumi re laser ou infrarouge nuisible vos yeux Ne regardez jamais en direction de fibres optiques ou d un port connecteur Supposez toujours que les c bles de fibres optiques sont connect s une source de lumi re Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 76 Translation of safety messages Copyright 2008 Nortel Networks WARNING WARNUNG Risiko einer Augenverletzung durch Laser Glasfaserger te k nnen Laserstrahlen oder ultraviolettes Licht aussenden das Ihre Augen verletzen kann Schauen Sie nie direkt in einen Glasfaserleiter oder Verbindungsanschluss Gehen Sie immer davon aus dass Glasfaserkabel mit einer Lichtquelle verbunden sind WARNING ADVERTENCIA Riesgo de lesi n en los ojos por l ser El equipo de fibra ptica puede emitir una luz l ser o infrarroja que dafie sus ojos Nunca mire un puerto de fibra ptica o conector Siempre asuma que los cables de fibra ptica est n conectados a una fuente de luz WARNING AVISO O laser pode causar ferimentos no olho O equipamento de fibra tica pode emitir laser ou luz infravermelha que pode causar danos a sua vista Nunca olhe para dentro da fibra tica ou da
46. ons page 66 5 Restart the switch ATTENTION You can use a default password to log on if the switch reboots without any previously configured password and the high secure hsecure mode is enabled however you will be prompted to change the password For more information about the secure mode see Security NN46205 601 End Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 66 Configuration Please provide primary config file path flash config cfg Please provide primary image file path flash p80a41 xx img Please add system prompt Ethernet Routing Switch 8606 Please select CPU Master slot 5 6 5 Master CPU mgmt port autonegotiation n y n speed 10 100 10 Do you want to enable automatic savetostandby mode n y n Do you want to enable m mode support n y n Do you want to enable enhanced operation mode support n y n Procedure job aid Setup Utility prompt descriptions Press Enter to accept the default flash config cfg or enter a different file location for the primary configuration file To store the configuration file on the PCMCIA card use pcmcia config cfg Specifying the path to the file is optional Press Enter to accept the default flash p80a4 1xx img or enter a different file location for the primary image file Specifying the path to the file is optional I
47. oximately 49 5 kg 110 lbs 3 Hold the chassis in position and align the flanged end of each mounting rail with the two holes on each side of the vertical rack support Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 36 Installation 9075FA 4 Insert and tighten the rack mounting screws with a Phillips screwdriver End Installing the 8010co chassis in a 19 inch two post rack Install the 8010co chassis in a 19 inch two post rack Prerequisites Verify that you have the following tools and materials 12 Phillips head screws 1 Phillips screwdriver Procedure steps Step Action 1 Place the installation shelf at the bottom of the rack and inside the rails 2 Hold the installation shelf in position and align the shelf mounting rail with the two holes on each side of the vertical rack support 3 Insert a Phillips head screw through each installation shelf mounting hole and into the corresponding hole in the rack Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Installing the 8003 8006 and 8010 chassis cable guides 37 4 Add a hex nut to each screw and tighten using a hex wrench 5 Tighten each screw using a Phillips head screwdriver 6 If the holes in the rack vertical supports require clip nuts insert a clip nut into each of the 12 loca
48. per and or supplier is an intended beneficiary of this Section Some jurisdictions do not allow these limitations or exclusions and in such event they may not apply 4 General 1 If Customer is the United States Government the following paragraph shall apply All Nortel Networks Software available under this License Agreement is commercial computer software and commercial computer Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Nortel Networks Inc software license agreement 19 software documentation and in the event Software is licensed for or on behalf of the United States Government the respective rights to the software and software documentation are governed by Nortel Networks standard commercial license in accordance with U S Federal Regulations at 48 C F R Sections 12 212 for non DoD entities and 48 C F R 227 7202 for DoD entities 2 Customer may terminate the license at any time Nortel Networks may terminate the license if Customer fails to comply with the terms and conditions of this license In either event upon termination Customer must either return the Software to Nortel Networks or certify its destruction 3 Customer is responsible for payment of any taxes including personal property taxes resulting from Customer s use of the Software Customer agrees to comply with all applicable laws including all applicable export and import l
49. porta do conector Tenha sempre em mente que os cabos de fibra tica est o ligados a uma fonte de luz WARNING AVVISO Rischio di ustioni agli occhi dovute al laser Le apparecchiature con fibre ottiche possono emettere raggi laser o infrarossi in grado di provocare ferite agli occhi Non guardare mai all interno di una porta di connessione o una fibra ottica Tenere sempre presente che i cavi a fibra ottica sono collegati a una sorgente luminosa Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Safety practices and the hazards danger statement 77 Safety practices and the hazards danger statement DANGER Risk of injury by electric shock Before working on this equipment be aware of proper safety practices and the hazards involved with electrical circuits Use only power cords that have a grounding path Ensure the switch is properly grounded before powering on the unit DANGER DANGER Risques de blessure par choc lectrique Avant de manipuler cet quipement vous devez prendre connaissance des pratiques de s curit appropri es et des risques associ s aux circuits lectriques Utilisez uniquement des cordons d alimentation poss dant un conducteur de terre Assurez vous que le commutateur est correctement reli la terre avant de mettre l unit sous tension DANGER GEFAHR Verletzungsrisiko durch Stromschlag Informieren Sie sich ber entsprechende SicherheitsmaBnahmen
50. pt the default n if you do not want to enable Telnet Enter y if you want to enable TFTP Press Enter to accept the default n if you do not want to enable TFTP Enter y if you want to enable WEB server service Press Enter to accept the default n if you do not want to enable WEB server service Enter the IP address of the management port in the first CPU slot Enter the IP address of the management port in the second CPU slot Enter the IP address of the virtual management port Press Enter to accept the default 0 0 0 0 0 0 0 0 if you do not want to specify an IP address First net mgmt route Enter the IP address of the first network 0 0 0 0 0 0 0 0 management route Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 68 Configuration Second net mgmt route 0 0 0 0 0 0 0 0 Third net mgmt route 0 0 0 0 0 0 0 0 Fourth net mgmt route 0 0 0 0 0 0 0 0 IP address of the default VLAN 0 0 0 0 0 0 0 0 Do you want to save the changes Saving the parameters will update the files flash boot cfg and flash config cfg y n Enter the IP address of the second network management route static route from the network management port to a device in the network For security reasons the system does not accept a route to a network that conflicts with the main nonmanagement routing table and therefore does not
51. r death from high voltage or electric shock DANGER La mention Danger Tension lev e fournit des informations sur les moyens de pr venir une situation ou une condition qui pourrait entrainer un risque de blessure grave ou mortelle la suite d une tension lev e ou d un choc lectrique DANGER GEFAHR Hinweise mit Vorsicht Hochspannung bieten Informationen dazu wie man Situationen oder Umstande verhindert die zu schweren Personensch den oder Tod durch Hochspannung oder Stromschlag f hren k nnen Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 14 Regulatory Information and Safety Precautions DANGER PELIGRO Los avisos de Peligro Alto voltaje brindan informaci n acerca de c mo evitar una situaci n o condici n que cause graves lesiones a personas o la muerte a causa de una electrocuci n o de una descarga de alto voltaje DANGER PERIGO Avisos de Perigo Alta Tens o oferecem informacdes sobre como evitar uma situagao ou condic o que possa causar graves ferimentos ou morte devido a alta tens o ou choques el tricos DANGER PERICOLO Le indicazioni Pericolo Alta tensione forniscono informazioni per evitare situazioni o condizioni che potrebbero causare gravi danni alle persone o il decesso a causa dell alta tensione o di scosse elettriche DANGER Danger notices provide information about how to avoid a situation or condition that can cause serious per
52. rge ESD grounding jack when handling modules e Always set modules on appropriate antistatic material Handle modules using the faceplate Do not touch pins or electrical connections e Do not leave slots open Fill all the slots with modules or use slot covers to maintain safety compliance proper cooling and EMI containment in the chassis Ensure your environment meets the requirements for temperature humidity and cleanliness Replace the 8010co chassis air filter regularly approximately every three months to maintain proper cooling and airflow For instructions to replace the 8010co chassis air filter see Nortel Ethernet Routing Switch 8600 Routine Maintenance NN46205 312 Do not overtighten thumb screws or lug nuts Tighten screws and nuts until snug plus a quarter turn If you use a power tool to tighten screws use a low torque setting 2 to 3 inches per pound in Ib Cable and connector safety Use the following instructions to safeguard cables and connectors while working with the Ethernet Routing Switch 8600 e Support cables to prevent stress on connectors If the Ethernet Routing Switch 8600 has a high cable density configuration install additional cable management equipment Do not exceed the bend radius recommended for the cable type installed Fiber optic cables and connectors require special care Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Cop
53. rtel Networks Removing a power filler panel 33 Procedure steps Step Action 1 Remove the equipment from the shipping container and place the chassis on antistatic material 2 Check all items for damage ATTENTION If the equipment is damaged contact your Nortel sales representative 3 Use the following chassis shipping accessories checklist to verify that the shipping container includes all contents check Accessory uet Bracket kit two Support the chassis in an rack mounting brackets equipment rack and Phillips head screws Screw package Mount the chassis in an equipment rack Side cable management Manage network interface bracket two brackets for cables the 8010 chassis and one bracket for the 8006 and 8003 chassis Rubber footpads Keep the chassis from slipping when mounting on a flat surface Console cable with built in Connect an optional adapter management console to the chassis Each cable end has a female DB9 and a DB25 connector Cable guide Keep cable clusters fastened and out of the way but accessible for maintenance End Removing a power filler panel A power filler panel maintains the proper cooling airflow in the Ethernet Routing Switch 8600 chassis You must remove the power filler panel from the power bay when you install a power supply in a bay for the first time Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright
54. s de cuidado oferecem informac es sobre como evitar poss veis interrup es do servico ou danos aos produtos da Nortel CAUTION ATTENZIONE Le indicazioni di attenzione forniscono informazioni per evitare possibili interruzioni del servizio o danni ai prodotti Nortel Warning Notice WARNING Warning notices provide information about how to avoid personal injury when working with Nortel products Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright O 2008 Nortel Networks Copyright 2008 Nortel Networks Safety Messages 13 WARNING AVERTISSEMENT La mention Avertissement fournit des informations sur les moyens de pr venir les risques de blessure lors de la manipulation de produits Nortel WARNING WARNUNG Warnhinweise bieten Informationen dazu wie man Personenschaden bei der Arbeit mit Nortel Produkten verhindert WARNING ADVERTENCIA Los avisos de Advertencia brindan informaci n acerca de c mo prevenir las lesiones a personas al trabajar con productos Nortel WARNING AVISO Os avisos oferecem informa es sobre como evitar ferimentos ao trabalhar com os produtos da Nortel WARNING AVVISO Le indicazioni di avviso forniscono informazioni per evitare danni alle persone durante l utilizzo dei prodotti Nortel DANGER Danger High Voltage notices provide information about how to avoid a situation or condition that can cause serious personal injury o
55. s the server load balancing SLB Operator login to connect to the Web Switch Module WSM Slbadmin username Sets the SLB Administrator logon to connect to the WSM ssladmin username Sets the ssladmin logon to connect to and configure the SSL acceleration module SAM For more information about the WSM see Nortel Ethernet Routing Switch 8600 Web Switching Module Fundamentals NN46205 31 4 Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Changing passwords using the NNCLI 63 Changing passwords using the NNCLI Set new passwords for each access level or change the logon or password for various access levels of the switch The Ethernet Routing Switch 8600 ships with default passwords set for access to the NNCLI When using Simple Network Management Protocol version 3 SNMPv3 you can change passwords that are in encrypted format Prerequisites You must have read write all privileges to change passwords For security passwords are saved to a hidden file You must log on to the global configuration mode Procedure steps Step Action 1 Change a password by using the following command cli password word lt access level gt 2 Configure password options by using the following command password aging time day lt 1 365 gt default lockout time 60 65 000 gt min passwd len lt 10 20 gt password history lt 3 32 gt
56. se with designated hardware or Customer furnished equipment CFE Customer is granted a nonexclusive license to use Software only on such hardware or CFE as applicable Software contains trade secrets and Customer agrees to treat Software as confidential information using the same care and discretion Customer uses with its own similar information that it does not wish to disclose publish or disseminate Customer will ensure that anyone who uses the Software does so only in compliance with the terms Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 18 Software license of this Agreement Customer shall not a use copy modify transfer or distribute the Software except as expressly authorized b reverse assemble reverse compile reverse engineer or otherwise translate the Software c create derivative works or modifications unless expressly authorized or d sublicense rent or lease the Software Licensors of intellectual property to Nortel Networks are beneficiaries of this provision Upon termination or breach of the license by Customer or in the event designated hardware or CFE is no longer in use Customer will promptly return the Software to Nortel Networks or certify its destruction Nortel Networks may audit by remote polling or other reasonable means to determine Customer s Software activation or usage levels If suppliers of third party software included in
57. sonal injury or death DANGER La mention Danger fournit des informations sur les moyens de pr venir une situation ou une condition qui pourrait entrainer un risque de blessure grave ou mortelle DANGER GEFAHR Gefahrenhinweise stellen Informationen dar ber bereit wie man Situationen oder Umst nden verhindert die zu schweren Personensch den oder Tod f hren k nnen DANGER PELIGRO Los avisos de Peligro brindan informaci n acerca de c mo evitar una situaci n o condici n que pueda causar lesiones personales graves o la muerte DANGER PERIGO Avisos de perigo oferecem informac es sobre como evitar uma situa o ou condig o que possa causar graves ferimentos ou morte Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Safety Messages 15 DANGER PERICOLO Le indicazioni di pericolo forniscono informazioni per evitare situazioni o condizioni che potrebbero causare gravi danni alle persone o il decesso Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks atory Information and Safety Precautions Switch 8600 Standard 8 Copyright 2008 Nortel Networks 17 Software license This section contains the Nortel Networks software license Nortel Networks Inc software license agreement This Software License Agreement License Agreement is bet
58. ssurez vous que la source d alimentation en courant continu est teinte DANGER GEFAHR Verletzungsrisiko durch Stromschlag Bevor Sie dieses Verfahren fortsetzen stellen Sie sicher dass die Stromquelle f r Wechselstrom ausgeschaltet ist DANGER PELIGRO Riesgo de lesi n por electrocuci n Antes de continuar con este proceso aseg rese de que la fuente de alimentaci n de CC est apagada DANGER PERIGO Risco de ferimentos por choque el trico Antes de continuar este procedimento certifique se de que a fonte de energia DC est desligada DANGER PERICOLO Rischio di scosse elettriche Prima di continuare questa procedura accertarsi che la fonte di alimentazione CC sia disattivata Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Nortel Ethernet Routing Switch 8600 Quick Start Copyright 2008 Nortel Networks All Rights Reserved Printed in Canada India and the United States of America Release 5 0 Publication NN46205 310 Document status Standard Document revision 02 01 Document release date 30 May 2008 To provide feedback or to report a problem in this document go to www nortel com documentfeedback www nortel com LEGAL NOTICE While the information in this document is believed to be accurate and reliable except as otherwise expressly agreed to in writing NORTEL PROVIDES THIS DOCUMENT AS IS WITHOUT WARRANTY OR CONDITION OF ANY KIND EITHER EXPRESS
59. switching off the circuit breaker or disconnecting at the remote end before you connect the terminal leads to the power supply Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 46 Installation Copyright 2008 Nortel Networks 1 Ground studs 2 Positive power inputs 3 Negative power inputs 1 Ground studs 2 Positive power inputs 3 Negative power inputs Attach the earth ground lead to the ground stud on the power supply Use the washers in the following order flat washer crimp lug lock washer hex nut Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Installing DC power modules 47 EN bi en Le CS fro Qm mm 4 Grournding stud 4 Lock washer 2 e Flat washer 6 Hex nul 3 Diro ug 6 Earth ground bad 101A 7 Attach the positive voltage lead to the positive terminal on the power supply inserting a lock washer between the crimp lug and each hex nut Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 48 Installation 10 11 12 13 14 15 16 Copyright 2008 Nortel Networks Attach the negative voltage lead to the negative terminal on the power supply inserting a lock washer between the crimp lug and each hex nut Tighten the hex nut using a 7 16 in
60. t 2008 Nortel Networks 30 Installation preparation Switch 8600 Standard 8 Copyright 2008 Nortel Networks 31 Installation This chapter contains installation instructions for the Ethernet Routing Switch 8000 series chassis Navigation e Unpacking the chassis page 32 e Removing a power filler panel page 33 Installing an Ethernet Routing Switch 8003 8006 or 8010 chassis into a rack page 34 Installing the 8010co chassis in a 19 inch two post rack page 36 Installing the 8003 8006 and 8010 chassis cable guides page 37 Installing the top cable management bracket page 38 Installing the side cable management brackets page 39 e Grounding the 8010co chassis page 40 Installing a module page 41 Installing AC power modules page 43 Installing DC power modules page 44 e Installing a breaker interface panel page 49 Installing a PCMCIA software card page 49 e Starting the system page 49 e Verifying a successful installation page 51 Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 32 Installation Unpacking the chassis Unpack the shipping container to ensure the chassis and all accessories are included and undamaged Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 No
61. t is 3 To set this option to the default value use the default operator with the command For more information about the WSM see Nortel Ethernet Routing Switch 8600 Web Switching Module Fundamentals NN46205 31 4 Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Configuring the system using the setup utility 65 Configuring the system using the setup utility Use the setup utility for the initial configuration of the switch The setup utility uses a series of questions to guide you through the configuration process ATTENTION Answer each question or accept the default by pressing Enter Each question includes the default value in brackets and the acceptable parameter options in parenthesis Procedure steps Step Action 1 Power up the system 2 Connect through the console and logon as a default user using the following command install ATTENTION You must connect to the master CPU to use the install script After running the setup utility remember to reboot the switch A Welcome to the Ethernet Routing Switch 8000 Setup Utility message appears stating you are starting initial configuration of the switch The data is stored in the flash boot cfg and runtime configuration flash config config files 3 If you want to continue type y 4 Follow the setup utility prompts See Procedure job aid Setup Utility prompt descripti
62. tes Verify that you have the following tools and materials Cable Crimping tool for crimping the lugs onto the cable Heat gun to shrink the tubing around the cable optional Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Installing DC power modules 45 A 7 16 inch hex wrench Phillips screwdriver Ensure the filler panel or cover is removed from the power bay To remove the filler panel see Removing a power filler panel page 33 ATTENTION Nortel does not supply the cables for connecting the DC power supply to the DC input power source Select cables that comply with the electrical code of the country where you use the DC power supply Procedure steps Step Action 1 Make sure that the power switch is turned off 2 Grasp the handle of the new power supply and push it partway into the bay leaving the terminal block at the side of the power supply exposed 3 Remove the screw that secures the plastic safety cover to the power supply using a Phillips screwdriver 4 Remove the cover and set it aside 5 Record the positions of the ground stud and of the positive and negative power inputs ATTENTION Make sure the DC cable is always connected to the positive terminal and that the DC cable is always connected to the negative terminal DANGER Risk of injury by electric shock Make sure that the DC power source is off by
63. tions 7 Lift the 8010co chassis onto the installation shelf WARNING Risk of personal injury It requires three people to lift the 8010co chassis To make the chassis lighter remove the modules and power supplies before you lift it 8 Hold the 8010co chassis in position and align the flanged end of the chassis mounting rail with the six holes on each side of the vertical rack support Make sure the hole pairs on each side of the vertical support match horizontally 9 Tighten each screw using a Phillips head screwdriver End Installing the 8003 8006 and 8010 chassis cable guides Install the 8003 8006 and 8010 chassis cable guides to fasten the cable clusters and keep them out of the way ATTENTION Ensure the cable clusters are accessible for maintenance Procedure steps Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks 38 Installation Action Loosen but do not remove the rack mounting screws required to install a cable guide Slide the cable guide onto the loosened screws 10246FA Tighten the screws to secure the cable guide to the chassis End Installing the top cable management bracket Install the top cable management bracket to the 8010co chassis Procedure steps Step 1 Action Align the mounting retainers on the inside of the top cable management bracket with the holes on the front of the chassis
64. to point link The default is 0 0 0 0 pppfile lt file gt Identifies the file to use for PPP initialization parameters Procedure job aid DTE to DCE straight through pin assignments Table 3 DTE to DCE straight through pin assignments DCE DB 9 DCE DB 25 pin number pin number Connecting a modem using the NNCLI Connect a modem to a Ethernet Routing Switch 8600 to establish a connection with the switch To connect a modem to an Ethernet Routing Switch you may need to set up the modem port using another type of connection such as a terminal connection to the NNCLI You can access the NNCLI through a modem connection to the Ethernet Routing Switch 8690SF 8691SF CPU or 8692SF CPU modules ATTENTION Nortel recommends that you use the default settings for the modem port for most modem installations Prerequisites You need a DTE to DCE cable straight or transmit cable to connect the Nortel Ethernet Routing Switch 8600 to the modem You must configure your client dial up settings to establish the connection to the modem You must log on to the Global Configuration mode in the NNCLI Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Connecting a modem using the NNCLI 57 Procedure steps Step Action 1 Configure port parameters based on the requirements of the modem by using the following command boot config sio modem For inform
65. turn them on 3 Verify that the power LED on each power supply turns green 4 Verify that the power supply status LEDs and the fan LED on the 8691SF CPU or 8692SF CPU modules turn green 5 Verify that air flows from the cooling fans through the chassis vents ATTENTION The red fan tray fail LED may light briefly while the fans power to operational speed End Turning on DC power supplies Step Action 1 Turn the power switch on each DC power supply to the on position It is not necessary to remove the bezel to turn the switch on ATTENTION If the chassis contains two or three power supplies turn on the power supplies simultaneously If you wait longer to turn on the second power supply one of the power supplies can turn off within 7 seconds To correct this condition turn off the power supplies for a short period of time and then simultaneously turn them on 2 Verify that the power output LED for each power supply turns green 3 Verify that the power supply status LEDs and the fan LED on the 8691SF CPU or 8692SF CPU modules turn green Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Verifying a successful installation 51 ATTENTION The red fan tray fail LED may light briefly while the fans power to operational speed End LED power supply After you turn on the Ethernet Routing Switch 8000 Series each module automaticall
66. ug that fits over one of the grounding studs A nut and locking washer for the grounding stud A 6 AWG grounding wire long enough to connect to the ground point A 7 16 inch hex wrench to fasten the hardware in the correct order Procedure steps Step Action 1 Locate the shelf grounding point on the rack The rack grounding point is a grounding strip located on the back base top or side ATTENTION The rack grounding strip can look different than the one shown in Procedure job aid Grounding the 8010co chassis page 41 the procedure job aid 2 Attach the lug ends of the chassis ground cables to the rack grounding strip using a 7 16 inch hex wrench to fasten the hardware in the correct order For more information see Procedure job aid Grounding the 8010co chassis page 41 End Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Installing a module 41 Procedure job aid Grounding the 8010co chassis Figure 1 Location of ground studs on a 8010co chassis rear panel 1 Grounding studs 1 He head bolt 3 Ground crimo lug 2 Lock washer 4 Rack grounding ship Installing a module Install Ethernet Routing Switch 8600 modules to provide communications interfaces for switching and routing operations Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008
67. uttore sia adeguatamente collegato alla messa a terra Safety practices and the hazards danger statement DANGER Risk of injury by electric shock Before working on this equipment be aware of proper safety practices and the hazards involved with electrical circuits Use only power cords that have a grounding path Ensure the switch is properly grounded before powering on the unit DANGER Risques de blessure par choc lectrique Avant de manipuler cet quipement vous devez prendre connaissance des pratiques de s curit appropri es et des risques associ s aux circuits lectriques Utilisez uniquement des cordons d alimentation poss dant un conducteur de terre Assurez vous que le commutateur est correctement reli la terre avant de mettre l unit sous tension Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Safety practices and the hazards danger statement 79 DANGER GEFAHR Verletzungsrisiko durch Stromschlag Informieren Sie sich ber entsprechende SicherheitsmaBnah men und die mit Stromkreisen verbundenen Gefahren bevor Sie mit diesem Ger t arbeiten Verwenden Sie nur Netzkabel mit Erdungspfad Stellen Sie sicher dass der Schalter ordnungsgem geerdet ist bevor Sie das Ger t einschalten DANGER PELIGRO Riesgo de lesi n por electrocuci n Antes de trabajar con este equipo inf rmese acerca de las medidas de seguridad a
68. ween you the end user Customer and Nortel Networks Corporation and its subsidiaries and affiliates Nortel Networks PLEASE READ THE FOLLOWING CAREFULLY YOU MUST ACCEPT THESE LICENSE TERMS IN ORDER TO DOWNLOAD AND OR USE THE SOFTWARE USE OF THE SOFTWARE CONSTITUTES YOUR ACCEPTANCE OF THIS LICENSE AGREEMENT If you do not accept these terms and conditions return the Software unused and in the original shipping container within 30 days of purchase to obtain a credit for the full purchase price Software is owned or licensed by Nortel Networks its parent or one of its subsidiaries or affiliates and is copyrighted and licensed not sold Software consists of machine readable instructions its components data audio visual content such as images text recordings or pictures and related licensed materials including all whole or partial copies Nortel Networks grants you a license to use the Software only in the country where you acquired the Software You obtain no rights other than those granted to you under this License Agreement You are responsible for the selection of the Software and for the installation of use of and results obtained from the Software 1 Licensed Use of Software Nortel Networks grants Customer a nonexclusive license to use a copy of the Software on only one machine at any one time or to the extent of the activation or authorized usage level whichever is applicable To the extent Software is furnished for u
69. y initiates a diagnostic test to verify proper module function If the power supply LED remains off do the following Procedure steps Step Action 1 Turn the power switch on each power supply to the off position 2 Wait 1 minute 3 Turn the power switch on each power supply to the on position End Verifying a successful installation e The following list describes a successful starting sequence for an Ethernet Routing Switch When power is applied to the Ethernet Routing Switch 8000 the green LED on each power supply and fan tray or cooling module turns on and the Online LED for each module is amber Each module initiates a self test during which time the port and module LEDs display various patterns to indicate the progress of the self test Upon successful completion of the self test within 2 or 3 minutes after power is applied to a fully loaded chassis the module Online LED transitions from amber to green After 1 minute of operation the fan tray Pass LED lights remain green f the LEDs on the modules light in this sequence your installation is successful Contact your network administrator to verify that the Ethernet Routing Switch 8000 is connected to the network Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyright 2008 Nortel Networks Jting Switch 8600 Standard 8 Copyright 2008 Nortel Networks 53 Configuration
70. yright 2008 Nortel Networks Safety precautions 29 Protect connectors with rubber safety plugs when cables are not inserted Follow appropriate fiber cleaning procedures to install or replace cables Do not exceed the bend radius recommended for fiber optic cables The acceptable bend radius for fiber optic cable is ten times its diameter or 2 5 to 5 cm 1 to 2 in Anything less than the recommendation can cause a loss of integrity during data transmission It is difficult to diagnose loss of integrity because of incorrect bend radius Electrostatic discharge safety Electrostatic discharge ESD is the transfer of charge between objects at different electrical potentials ESD can change the electrical characteristics and degrade or destroy a semiconductor device ESD can also disrupt the normal operation of an electronic system by causing equipment malfunction or failure To dissipate or neutralize electrostatic charges use proper grounding and conductive or dissipative materials CAUTION Risk of equipment damage To prevent damage from electrostatic discharge always wear an antistatic wrist strap connected to an electrostatic discharge ESD jack Proper antistatic packaging effectively shields products from electrostatic charges and reduces the charge generation caused by product movement within the container Nortel Ethernet Routing Switch 8600 Quick Start NN46205 310 02 01 Standard 30 May 2008 Copyrigh

Download Pdf Manuals

image

Related Search

Related Contents

CS 30Y • CS 35Y • CS 40Y • CS 45Y  Tripp Lite 2-Prong European Computer Power Cord (C5 to SCHUKO CEE 7/7), 6-ft.  Targus Blacktop 15.4" Standard Laptop Case Dome Protection  手引き書 - 中部地方整備局 港湾・空港部  Chaville Magazine  Bedienungsanleitung E  Serie KPD Manual DVR MPEG-4  User Manual - Actionstar  Lenovo 04N7324 User's Manual  LDKIT Laser Control Kit User Manual RevA  