Home

Nikon Monarch Gold (E) User's Manual

image

Contents

1. Magnification Objective Diameter Exit Pupil Eye Relief Battery Reticle Intensity Adjustment _ Field of View at 110yds Tube Diameter Objective Tube Dia Length Weight Adjustment Graduation Maximum Internal Adjustment Elevation amp Windage Parallax Settings Outside Diameter of Eyepiece moa minute of angle Deviation is 27 8mm at 100m 1in at 100 yds 25 4mm at 91 44m 1 5 6x42 1 55 5 82 mm 42 in 1 65 mm 7 2 in 0 28 mm 104 102 in 4 09 4 02 m 19 7 5 27 ft 64 7 17 3 mm 30 in 1 18 mm 50 in 1 97 mm 290 in 11 42 9 490 oz 17 3 1 4 1 click moa 120 m 91 44 yards 100 mm 43 in 1 69 2 5 10x50 SF 2 58 9 7 50 1 97 5 2 0 20 102 101 4 02 3 98 11 83 3 20 38 8 10 5 30 1 18 58 2 28 330 12 99 600 21 2 1 4 1 click 80 at least 45 72 00 at least 50 00 43 1 69 2 5 10x56 SF 2 59 9 75 56 2 20 5 7 0 22 102 4 02 6 position OFF to 5 for Green color and Red color 11 83 3 20 38 8 10 5 30 1 18 65 2 56 350 13 78 670 23 6 1 4 1 click 80 at least 45 72 00 at least 50 00 43 1 69 1 1 4x24 Dual Illuminated Reticle 1 1 4x 24 0 94 6 0 0 24 94 94 3 7 3 7 2 5 10x50 SF Dual Illuminated Reticle 2 58 9 7 50 1 97 5 2 0 20 102 101 4 02 3 98 3 Volts Lithium CR2032 32 93 8 93 108 29 3 30 1 18 30 1 18 267 10 51 480 16 9 1 4 1
2. click 80 91 44 100 43 6 1 72 11 83 3 20 38 8 10 5 30 1 18 58 2 28 330 12 99 660 23 3 1 4 1 click 80 at least 45 72 00 at least 50 00 43 1 69 2 5 10x56 SF Dual Illuminated Reticle 2 59 9 75 56 2 20 5 7 0 22 102 4 02 11 83 3 20 38 8 10 5 30 1 18 65 2 56 350 13 78 720 25 4 1 4 1 click moa 80 at least 45 72 00 at least 50 00 43 1 69 Nikon riflescopes are factory set to be parallax free at 100 yds 91 44 m 2 5 10x50 SF allow free adjustment from 50yds 45 72 m up to infinite point Instructions 1 Battery CAUTION When installing batteries make sure the firearm is unloaded Use safe firearm handling practices at all times Your Nikon Monarch Gold E 2 5 10x50 SF and 2 5 10x56 Dual Illuminated Reticle are powered by one 3V lithium battery CR2032 or equivalent When your reticle grows dim or not light at all you need to replace the battery How to replace battery 1 Hold the rheostat intensity dial tightly and turn the cover with coin counter clockwise 2 Take out the old battery and put one 3V Lithium Battery into the compartment Be sure side to be Up 3 Put the cover back and turn it clockwise with coin until the cover is firmly secured 4 Turn the rheostat intensity dial to the desired color red or green and intensity OFF to 5 6 steps 2 Focusing 1 Look through the eyepiece with your eye positioned about 10cm 4
3. in away from the eyepiece lens Fig 3 1 and you will see the Nikoplex reticle Fig 3 2 the Reticle 4 reticle Fig 3 3 or the IL Reticle 4 reticle Fig 3 4 or the BDC reticle Fig 3 5 On the model IL Reticle 4 reticle if the illumination function is turned on only the intersection point of the cross wire appears faintly illuminated Be sure your eye is positioned within proper alignment and proper eye relief otherwise the view will black out 2 Point the objective end of the scope at the sky Do not point at the sun or at a plain unpatterned wall Turn the eyepiece adjustment counter clockwise and then turn it clockwise until the reticle appears sharp 1 Eyepeice Adjustment 2 Eye Relief Non illuminated Reticle model MI RISP f ie T An ay E 7 PRE au Da r bre dd Dre Va 7 E Fig 3 1 Abb 3 1 The reticle should be immediately crisp and clear to the quick glance PPPE Fig 3 2 Fig 3 3 Fig 3 4 Fig 3 5 Abb 3 2 Abb 3 3 Abb 3 4 Abb 3 5 Nikoplex Reticle Reticle 4 Reticle IL Reticle 4 Reticle BDC reticle 2 5 10x50 only Illuminated Reticle model only 3 Magnification e The Nikon Monarch Gold E 2 5 10x50 SF and 2 5 10x56 SF have a variable magnification from 2 5 to 10x 1 5 6x42 from 1 5 to 6x 1 1 4x24 from 1 1 to 4x To change powers just rotate the power selector ring until the desired magnification appears adjace
4. Nikon Monarch Gold E 2 5 10x50 SF 2 5 10x56 SF 1 5 6x42 and 1 1 4x24 are calibrated in division of 1 4 minute of angle with a click at intervals of 1 4 minute of angle one division e When adjusting the reticle to the point of aim remember that one minute of angle equals approximately one inch 2 54 cm at 100 yards 91 44 m Therefore if the impact point is two inches 5 08 cm low and one inch 2 54 cm right at 100 yards 91 44 m Parallax Setting you should adjust two minutes of angle up one minute of angle left In case of 50 yards 45 72 m Parallax Setting the adjusting value is double In case of 75 yards 68 58 m Parallax Setting is 1 5 times M i TI qi Lock ShlieBen Serrure Fig 3 9 Cerrar Abb 3 9 Serratura 5 Adjustable objective The Nikon Monarch Gold E 2 5 10x50 SF and 2 5 10x56 SF can be more precisely focused within the range of at least 50 yards 45 72 m infinity by rotating the Side Focus adjustment ring Parallax can be eliminated and sight alignment will be accurate Use its distance scale as a reference guide The Side Focus adjusting ring has a locking system To loosen locking system pull the Side Focus adjustment ring out Fig 3 9 Then set the parallax free distance and push the adjusting ring in to lock the ring Maintenance 1 Lens cleaning To remove dirt or fingerprint soak gauze or lens cleaning paper silicon free paper sold at camera shop with a small quantity of ab
5. Nikon Riflescope Monarch Gold E 2 5 10x50 SF 2 5 10x50 SF Dual Illuminated Reticle 2 5 10x56 SF 2 5 10x56 Dual Illuminated Reticle 1 5 6x42 1 1 4x24 Dual Illuminated Reticle Instruction manual Congratulations on your choice of a Nikon RIFLESCOPE Your new scope is the finest example of Nikon s rugged and durable construction and precision bright optics important qualities for a serious shooter s riflescope Whether you use your scope for hunting or for target shooting the procedure for mounting is identical You should acquire a set of high quality steel mounting rings which have a standard diameter of 30 mm Follow the ring manufacturer s instructions for mounting procedures After mounting the scope on your rifle follow the procedures for reticle alignment Caution 1 Do not look at the sun through the riflescope It will permanently damage your eye This precaution applies to all optical devices such as cameras and binoculars 2 The riflescope is effectively sealed against moisture and dust You may use your scope safely either in the rain or in dusty climates To preserve the appearance of the scope we suggest that it be dried and cleaned prior to storage Use a soft cloth for cleaning metal surfaces and use photographic lens tissue to clean the scope s lenses When setting the reticle for hunting you should determine your standard range and then adjust the reticle based upon that target distance For targets which
6. nt to the power index dot 4 Adjustment and Zero setting of the riflescope Sighting through the riflescope align the rifle with your aiming point on the target and shoot a trial round If the bullet does not hit the aiming point adjust the elevation and windage as follows If the bullet hits under the aiming point turn the elevation adjustment counter clockwise in the direction of the arrow marked U for up as in Fig 3 6 If the bullet hits high turn adjustment clockwise in the direction of the arrow marked D for down lf the bullet hits to the right of the aiming point turn the windage adjustment clockwise in the direction of the arrow marked L for left as in Fig 3 7 If the bullet hits to the left of the aiming point turn adjustment counter clockwise in the direction of the arrow marked R for right e After the reticle has been adjusted to the point of impacts with the grip held with your fingers to avoid shifting of the aligned grip turn the grip screw in top of the grip counterclockwise with coin Then lift the grip up and align the Y with the index mark It may happen that the Y could not align with the index mark exactly because of the coupling pitch of the grip with the shaft And by securing the grip with your fingers to avoid shifting of the grip turn the grip screw clockwise with the coin until the grip is firmly secured Fig 3 8 Note e The windage and elevation scales of the
7. solute alcohol available from drugstore and lightly wipe off Wiping with leather chamois is not recommended as it is likely to damage the lens surface Dust may scratch the lens surface or corrode the lens Brush dust off using a soft oil free brush 2 Scope Exterior Use a soft dry cloth to wipe off any dirt or finger prints that might accumulate It is not necessary to oil the scope s surface 3 Windage Elevation Adjustments These adjustments are permanently lubricated Do not attempt to lubricate them Cover with caps supplied except when adjusting to keep out dust and dirt 4 Eyepiece Adjustment This adjustment is permanently lubricated Do not attempt to lubricate 5 Power Selector Ring No lubrication is required on the power selector ring Do not loosen or remove screws in power selector ring In the event that you should require service for your Nikon RIFLESCOPE in case of USA market please send it directly to Nikon Scope Service 841 Apollo Street Suite 100 El Segundo CA 90245 4721 1 800 Nikon SV In other market please bring it to dealer from which you purchased it Nikon Inc 1300 Walt Whitman Road Melville NY 11747 3064 P 631 547 8632 F 631 547 4040
8. vary from that standard distance you may simply adjust the position of the reticle in relation to your target or you may wish to use the procedure for trajectory compensation It s up to your personal preference We hope that you will enjoy your new Nikon RIFLESCOPE for many years to come Enjoy using it and above all always follow safe shooting procedures 1 Nomenclature Objective Lens Eyepiece Lens Elevation Adjustment Windage Adjustment Eyepiece Adjustment Power Index Dot Power Scale Power Selector Ring Side Focus Adjustment Ring Side Focus Distance Scale Distance Scale Index Adjustment Cap 13 14 OONOOUAWN Rheostat Intensity Dial Battery Compartment Cover I a 2 5 10x50 SF O 4 Fig 1 1 2 5 10x56 SF Abb 1 1 2 5 10x50 SF Dual Illuminated Reticle i 2 5 10x56 SF Dual Illuminated Reticle ms mme cn SP Fig 1 3 1 5 6x42 Abb 1 3 1 4x24 Dual Illumi i 1 ual Illuminated Reticle Fig 1 4 Abb 1 4 ITEM SUPPLIED Body Eyepiece cap Objective ul Battery 3V Lithium battery CR2032 Dual illuminated Reticle model only 1pc 1 pair 1pc TTT Fig 1 5 Abb 1 5 Magnified Figure of Hand turn Grip Vergr Berte Darstellung des Handdrehgriffs Sch ma agrandi de la poign e rotation manuelle llustracion ampliada de cilindro de ajuste manual Figura ingrandita dell impugnatura a rotazione manuale TTT e aa 2 Specifications Model Actual