Home
NewAir AD-400 User's Manual
Contents
1. When the dehumidifier is in operation maintain minimum clearance around the unit as shown in the diagram on the right 20cm 20cm TROUBLESHOOTING If one of the problems listed below exists check the following conditions before contacting customer service Possible Causes The unit does not operate Has the power cord been Plug the power cord back disconnected into the outlet Is the Full Tank Indicator Empty the water in the Light blinking the tank drainage tank and is either full or in a reposition it back into the wrong position tank Is the temperature in the The protective device is room above 95 F or activated and the unit below 41 F cannot be started The dehumidifying Is the air filter clogged Clean the air filter as function does not work instructed in Cleaning the Dehumidifier Is the intake or discharge Remove the obstruction duct obstructed from the discharge or intake duct No air is being Is the air filter clogged Clean the air filter as discharged from the unit instructed in Cleaning the Dehumidifier angle or unsteady sturdy location Is the air filter clogged Clean the air filter as instructed in Cleaning the Dehumidifier
2. s humidity level 2 When the desired humidity level is selected it will indicate this level 3 When the programmable timer is set it will indicator the hours set Button Functions Power Button Press this button once to begin operation The default humidity level will be 60 Press this button again to stop operation O rimer Button 24 Hour Timer Setting Press this button to program the time in which the unit turns on and off To cancel the timer function press the button to adjust the time to 00 adjustable Humidity Button The humidistat range for this dehumidifier ranges from 40 to 80 Press the Humidity Button to set the desired humidity level this can be set in increments of 5 The display will then show 60 65 80 40 45 60 The LED will turn on during this process When the dehumidifying function is in operation the LED light will turn on If the humidity level of the room is lower than the selected humidity level the unit will automatically stop dehumidifying and the fan will circulate the air Fan Speed Button Press this button to set the desired fan speed This can be adjusted between high and low speeds lon Button Press this button to set the ionic function Once pressed the LED light will turn on and to cancel the ionic function press the lon Button again OPERATION 1 Turning on the Unit After the unit is plugged in for the first time a buzzer will sound and the humidity ind
3. drainage tank back onto the unit press the tank firmly in place with both hands If the tank is not positioned properly the TANK FULL sensor will be activated and the dehumidifier will not operate Continuous Water Drainage This dehumidifier features a continuous drainage port To utilize this function use a plastic pipe with an inner diameter of 9 mm The water in the drainage tank can now be continuously drained out of the port on the unit MAINTENANCE Cleaning the Dehumidifier To Clean the Body To clean the body simply wipe it with a soft damp cloth Refrain from using harsh cleaners or detergents To Clean the Air Filter To clean the air filter following these steps 2 Run a vacuum cleaner lightly over the surface of the air filter to remove dirt dust and debris Ifthe air filter 1s exceptionally dirty wash it with warm water and a mild cleanser Remember to dry thoroughly s on i 3 Reattach the air filter by inserting it back into the unit Storing the Dehumidifier When not being used for an extended period of time properly store the unit by following these steps 1 Fold the power supply cord and secure it to the water tank 2 Discard any water left in the drainage tank Clean the air filter 4 Store the unit upright in a cool dry place and in its original packaging to keep it free from dust and debris U Clearance
4. will automatically stop to defrost every 45 minutes Adjustable Humidistat The built in humidistat allows you to select the desired humidity level for your room Programmable Timer The programmable timer allows you to set when the unit is to be turned on and or off Quiet Operation This dehumidifier operates at a low noise level and will not disturb your indoor environment Energy Efficient This dehumidifier consumes little power and is extremely energy efficient SAFETY WARNINGS When operating the unit please observe the following safety precautions 2 3 eae Unplug the power supply cord before cleaning or storage Do not submerge the unit in water or near damp areas Do not set the unit close to heat generating devices or near flammable and dangerous materials Do not place fingers or foreign objects into or near the intake or discharge ducts Do not sit or stand on the unit Empty water that has collected in the tank as required Do not operate the dehumidifier in an enclosed area such as inside a closet as this poses a fire hazard Install the drain piping at a downhill grade to ensure condensed water can be drained continuously If the power supply cord is damaged it must be replaced by the manufacturer or a qualified service agent PRODUCT DIAGRAM FRONT Control panel Louver Wheels REAR Handle Air filter Water tank Supply cord Continuous drainage port If the Un
5. AD 400 DEHUMIDIFIER Owner s Manual Please Keep These Instructions for Future Reference Thank You Thank you for purchasing this NewAir dehumidifier The following owner s manual will provide you with valuable information necessary for the proper care and maintenance of your new dehumidifier Please take a few moments to read these instructions thoroughly and to familiarize yourself with all the operational aspects of this dehumidifier FEATURES Because this dehumidifier removes unwanted moisture from the air it provides a more comfortable environment for your home or office In addition this unit can be conveniently moved from room to room with ease Here are some additional features this dehumidifier has to offer Powerful Dehumidification Capabilities By taking advantage of refrigeration technology this powerful dehumidifier removes excess moisture from the air in order to decrease the humidity level of a room or area As a result this keeps the indoor air dry and comfortable Lightweight amp Portable Design This dehumidifier is both compact and lightweight The casters on the bottom of the unit make it easy to move from room to room Low Temperature Operation with Automatic Defrost When the unit is operating in rooms where the temperature ranges from 41 F and 53 6 F it will automatically stop to defrost every 30 minutes When the unit is operating in rooms where the temperature ranges from 53 6 F and 68 F it
6. icator will show the default humidity level at 60 with low fan speed Press the button to start operation 2 Manually Opening the Louver Before operating the unit check to make sure the louver has been opened If the louver is closed the unit may overheat 3 Stopping Operation Press the POWER button to stop the dehumidification process Never turn off the unit by unplugging the supply cord DRAINING THE COLLECTED WATER When the drainage tank 1s full the Full Tank Indicator Light will turn on and the buzzer will beep 15 times to alert the user Operation will then stop automatically To continue operation the water will need to be emptied from the drainage tank Emptying the Drainage Tank 1 Lightly press the sides of the unit s tank with both hands and gently pull it out NE W 7 NL 2 Discard the collected water and replace the tank back onto the unit ANN AA K B PLEASE NOTE 1 Do not remove the float from the unit as doing so will prevent the water level sensor from correctly detecting the water level Moreover removing the float may cause water leakage from the unit s water tank emi i 2 Ifthe dramage tank is dirty rinse it with cold or lukewarm water Do not use detergent scouring pads chemically treated dust cloths gasoline benzene paint thinner or other solvents as these can scratch and damage the tank and cause water leakage 3 When replacing the
7. it is Not Operating 1 If the unit does not turn on please check up the plug 2 Ifthe Full Tank Indicator Light is on drain the tank before restarting the unit OPERATING INSTRUCTIONS G o O Q DAT 2 of TON SPEED SETTINGS TIMER POWER FULL Indicator Lights Full Tank Indicator Light The Full Tank Indicator Light will turn red when the drainage tank is full If this occurs empty the water out of the drainage tank and make sure the tank is positioned properly before restarting the unit O power Indicator Light Regardless of whether the unit is actually in operation the Power Indicator Light will turn green when the unit is plugged in Orimer Indicator Light The Timer Indicator Light will turn green when the timer function is set adjustable Humidity Setting Indicator Light The Adjustable Humidity Setting Indicator Light will turn green when the humidity level is set OO S Fan Speed Indicator Light The Right Fan Indicator Light located above the smaller fan icon will turn green when the unit is programmed to the low fan speed The Left Fan Indicator Light located above the larger fan icon will turn red when the unit is programmed to the high fan speed Ion Indicator Light The Ion Indicator Light will turn green when the ionizer setting is turned on HE Humidity Level amp Timer Indicator Lights This indicator features 3 functions 1 When the unit is plugged in it will indicate the room
Download Pdf Manuals
Related Search
Related Contents
IT700 Y-NET Package Quick Start Guide d`Utilisation et Manuel d`Installation 19 Mai 2013 - Site de Mister Février efectivas - Poverty Action Lab ガス器具は正しく使って ガス器具は正しく使って 安全で楽しいキャンプを LG RC700N User's Manual User Manual - Howard Computers URGENT – Programme volontaire de correction de RM-V70T Copyright © All rights reserved.