Home
Napoleon Fireplaces INDOOR AIR QAULITY WF 6/9/18 User's Manual
Contents
1. Screw the housing back onto the unit This must be screwed on very tightly or it will leak 6 TROUBLESHOOTING Water not flowing Pump not plugged in Plug pump into nearest GFI protected receptacle Insufficient water level Add water to recommended level Pump must be submerged by 1 2 at all times Water flow control valve Turn valve to on position turned off Filter plugged Replace filter Pump is vapour locked The pump may have an air bubble in it preventing it from pushing water through Unplug the pump and plug it back in several times or momentarily turn the valve to the purge setting Pump burned out Replace pump Dry spots on waterfall Improper start up procedure Ensure surface of waterfall is wet before starting by spraying with water or surface washing with wet cloth Insufficient flow Increase flow by opening water flow valve Surface not cleaned Clean with liquid TSP or TSP Substitute to remove oily residue properly Plugged ports in manifold Turn off water and remove manifold tube Inspect and clean See cleaning instructions Lights not working Lights not plugged in Plug lights into nearest electrical receptacle Bulb s are broken Replace light bulb s UV light not working UV light not plugged in Plug UV light into nearest electrical receptacle tional optional Bulb no longer good Replace UV light bulb Water leaking on floor Leaking connection Check all connec
2. 0012 n160 0012 n160 0012 5 8 hose clamp x 15 n160 0013 n160 0013 n160 0013 1 hose clamp x 16 n255 0034 n255 0034 n255 0034 3 4 bulkhead fitting x 17 n255 0037 n255 0037 n255 0037 3 4 male pipe to 3 4 barb elbow fitting x 18 n475 0149 n475 0150 n475 0151 waterfall panel stainless steel x n475 0152 n475 0153 n475 0154 waterfall panel black grooved acrylic ac 19 n335 0037 n335 0037 n335 0037 water basin lid x 20 n185 0002c n185 0002c n185 0002c water basin x 21 n255 0035 n255 0035 n255 0035 1 4 female pipe to 1 2 barb adapter fitting x 22 n517 0001 n517 0001 n517 0001 w ater pump x 23 n725 0023 n725 0023 n725 0023 float valve x 24 n010 0443 n010 0443 n010 0443 water basin housing x 25 n725 0022 n725 0022 n725 0022 3 w ay valve x 26 n255 0041 n255 0041 n255 0041 3 4 male pipe to 1 2 barb adapter fitting x 27 n350 0052 n350 0052 n350 0052 filter housing x 28 n252 0001 n252 0001 n252 0001 replacement filter 5 micron ac 29 n080 0177 n080 0177 n080 0177 filter mounting bracket x 30 n570 0043 n570 0043 n570 0043 8 32 x 3 4 stainless steel screw x 31 n402 0002 n402 0002 n402 0002 ultra violet light ac 32 n402 0008 n402 0008 n402 0008 ultra violet replacement bulb ac 33 n080 0171 n080 0171 n080 0171 ultra violet light mounting bracket ac 34 n255 0042 n255 0042 n255 0042 fitting plastic 1 2 male pipe 1 2 barb elbow x 35 n255 0039 n255 0039 n255 0039 fitting plastic 1 2 female pipe 1 2 female pipe elbow ac 36 n255 0040 n255 0040
3. Ph Ei gt Eg FROM THREE i WAY VALVE TO W FROM WATERFALL WATERFALL W DRAIN TO BASIN A B A WE FROM THREE WAY VALVE TO WATERFALL FROM BASIN TO WATERFALL DRAIN ve FROM WATER NS SOURCE TO as FLOAT VALVE INSTALL THE SUPPLIED was HOSE CLAMPS ON EITHER SIDE OF THE BASIN PROTECTION SADDLE VALVE y ig FLOW CONTROL VALVE PURGE OVERFLOW 4 va LIGHT WATER VALVE 3 f FILTER h TODRAIN PURGE LINE REMOVE COMPONENTS FROM BASIN AND ASSEMBLE AS SHOWN THE FITTINGS REQUIRED ARE ALREADY ATTACHED TO THE FILTER AND BASIN WHEN USING THE OPTIONAL UV LIGHT THE BARBED ELBOW FITTING ON THE IN SIDE OF THE FILTER WILL NEED TO BE REMOVED AND THREADED INTO THE ELBOW AT THE BOTTOM OF THE UV LIGHT THEN CON NECT THE UV LIGHT DIRECTLY TO THE FILTER USE TEFLON TAPE TO SEAL THESE CONNECTIONS ENSURE THAT THE SUPPLIED GROUND WIRE IS CONNECTED FROM THE GROUNDING TERMINAL ON THE UV LIGHT TO EITHER GROUNDED COPPER PLUMBING OR THE GROUND IN YOUR ELECTRICAL SYSTEM USE THE SUPPLIED SHORT PIECE OF BLACK TUBING TO RUN FROM THE PUMP TO THE UV LIGHT MEASURE AND CUT THE LINES TO THE LENGTH NECESSARY PUSH ONTO THE BARBED FITTINGS AND SECURE WITH THE SUPPLIED HOSE CLAMPS LEAK TEST THE WATERFALL BEFORE FULLY ENCLOSING 11 WATERFALL SURFACE INSTALLATION The stainless stee
4. excess moisture can lead to the formation of mold and mildew It is recommended that all homes have some form of humidity control and air exchange system to prevent such an occurence 3 WATER Water is perhaps the most critical component in the waterfall Dirty or contaminated water will quickly cause operational problems with your waterfall House water must be softened and filtered if the unit is to be connected to the water supply RO Reverse Osmosis water will give the best results and require the least amount of maintenance If the unit is not being connected to the house supply distilled bottled water is recommended The provided filter and optional UV light cannot prevent hard water deposits from forming on the surfaces of your waterfall Hard water will also cause plugged passages and manifold ports reducing the flow effect on the waterfall surface The life span of the pump will also be adversely affected due to the use of hard water Use of RO or distilled water is by far the best way of ensuring years of carefree enjoyment from your waterfall The provided particle filter will help prevent clogging of the manifold ports that disperse the water down the face of the waterfall The water that flows down the face will attract dust debris particles and mould spores that are floating in the air in your home This will help to naturally filter the air you breath and keep your home cleaner However the filter will become contaminated and the
5. HT 4 00 CENTERS 24 RECOMMENDED WIDTH CHECK WITH YOUR LOCAL BUILDING AUTHORITY FOR COMPLETE FRAMING GUIDELINES THE CHART BELOW WILL GIVE YOU THE OPENING SIZE REQUIRED FOR EACH MODEL MODEL HEIGHT WIDTH 49 00 26 750 49 00 38 625 WF18 84 25 38 625 Additional height may be required to ensure adequate drop to the pump module PIPING DIAGRAM WITHOUT UV LIGHT N570 0043 8 32 X 3 4 TO ELECTRICAL OUTLET FROM THREE WAY VALVE TO FROM WATERFALL WATERFALL i J DRAIN TO BASIN af EG FROM THREE WAY FROM BASIN TO VALVE TO WATERFALL WATERFALL DRAIN FROM WATER SOURCE TO FLOAT VALVE INSTALL THE SUPPLIED HOSE CLAMPS ON EITHER SIDE OF THE BASIN CUT THE SHORT PIECE OF BLACK TUBING TO 14 SADDLE VALVE NOT INCLUDED son FLOW CONTROL OVERFLOW WATER VALVE PURGE PROTECTION VALVE FILTER TO DRAIN PURGELINE REMOVE COMPONENTS FROM BASINAND ASSEMBLE AS SHOWN THE FITTINGS REQUIRED ARE ALREADY ATTACHED TO THE FILTERAND BASIN MEASURE AND CUT THE LINES TO THE LENGTH NECESSARY PUSH ONTO THE BARBED 10 FITTINGS AND SECURE WITH THE SUPPLIED HOSE CLAMPS LEAK TEST THE WATERFALL BEFORE FULLY ENCLOSING PIPING DIAGRAM WITH UY LIGrIT N570 0043 8 32 X 3 4 ELECTRICAL OUTLET
6. SERIAL S RIEZ INDOOR AIR QUALITY DECORATIVE INDOOR WATERFALLS THAT PURIFY AND HUMIDIFY THE AIR WF 6 9 18 MANUFACTURED BY MANUFACTURE PAR NAPOLEON APPLIANCE CORP ERE 214 BAYVIEW DR BARRIE ONTARIO CANADA LAN 4Y8 PHONE 705 726 4278 i FAX 705 725 2564 EMAIL ask nac on ca WEB SITE www napoleongrills com ae RETAIN THIS MANUAL FOR FUTURE REFERENGE GARDER CE LIVRE POUR REFERENCES FUTURES ER e NAPOLEON WATERFALLS NAPOLEON waterfalls are manufactured under the strict Standard of the world recognized ISO 9001 2000 Quality Assurance Certificate NAPOLEON products are designed with superior components and materials and are assembled by trained craftsmen who take great pride in their work Every component is thoroughly in spected by qualified technician before packaging and shipping to ensure that you the customer receive the quality product you expect from NAPOLEON NAPOLEON WATERFALL PRESIDENT S WARRANTY NAPOLEON warrants the materials and workmanship in your new NAPOLEON Waterfall against defects for a period of one year This excludes filters light bulbs and UV light bulbs NAPOLEON shall not be liable for any transportation charges labour costs installation or removal costs water damage or export duties CONDITIONS AND LIMITATIONS NAPOLEON warrants its products against manufacturing defects to the original purchaser only ie the individual or legal entity registered cu
7. T PARTS Before contacting the customer service department check the NAC web site for more extensive cleaning maintenance trouble shooting and part replacement instructions at www napoleongrills com Contact the factory directly for replacement parts and warranty claims The customer service department is available between 9 AM and 5 PM Eastern standard time at 1 866 820 8686 or fax at 1 705 727 4282 In order to process a claim we must be provided with the following information 1 Model and serial number of the unit 2 Part number and description 3 A concise description of the problem broken is not sufficient 4 Proof of purchase photocopy of the invoice In some cases the customer service representative may request to have the parts returned to the factory for inspection before providing replacement parts The parts must be shipped prepaid to the attention of the customer service department with the above information Before contacting customer service kindly note that the following items are not covered by the warranty costs for transportation brokerage or export duties labour costs for removal and reinstallation costs for service calls to diagnose problems discoloration of stainless steel parts part failure due to lack of cleaning and maintenance or use of improper cleaners NOTES FRAMING SPECIFICATIONS 2x6 HEADER PANEL RECOMMENDED CHECK WITH LOCAL CODES HEIG
8. adjustable wrench to house water supply 3 8 nut driver teflon tape pliers possible additional 1 2 i d tubing and 3 4 i d tubing depending on location of unit flat screw driver liquid TSP Trisodium Phosphate or TSP Substitute cleaner APPROPRIATE LOCATION There are several things to consider when choosing the appropriate location to install your waterfall The waterfall is designed to be installed into a 2 x 4 interior wall The waterfall should not be installed in a load bearing wall unless it can be framed in with proper supports and headers as required by your local building codes Check with your local building authority for specifications Installing the waterfall in an exterior wall is not recommended as it cannot be properly insulated If there are no suitable alternative locations then the waterfall can be installed in a 2 x 6 wall using rigid foam insulation between the exterior of the house and the back of the fountain The waterfall cannot be installed in a 2 x 4 exterior wall The lights pump and optional UV light require power Make sure you choose a location that has the available power within reach of the supplied electrical cords The receptacle must be GFI ground fault interrupt protected Electrical work must be done by a qualified electrician Check with your local building authority for specifications for your area Do not run extension cords behind walls An area to locate the
9. e right to have its representative inspect any product or part prior to honouring any warranty claim NAPOLEON shall not be liable for any transportation charges labour costs installation or removal cost water damage or export duties INDOOR AIR QUALITY Your new NAPOLEON waterfall will dramatically improve the indoor air quality in your home The waterfall is a natural humidifier which helps alleviate dry skin and allergies This is extremely beneficial in dry climates and also cold climates where forced air furnaces dry the air The waterfall also cleans the air by attracting contaminants Moving water attracts airborne particles such as dust pet dander pollen and other pollutants The waterfall draws these particles into the water which is then filtered through a 5 micron filter before being recirculated The result is cleaner fresher humidified air Waterfalls also generate negative ions These odourless tasteless invisible molecules are created in nature as air molecules break apart due to sunlight radiation and moving air and water Researchers now believe that negative ions aid in alleviating depression reducing stress and boosting energy INSTALLATION TOOLS AND MATERIALS REQUIRED Before you begin hooking up the fountain ensure that you have access to the following materials and tools Tools Materials utility knife saddle valve and 1 4 tubing ice maker plumbing kit required if unit is being connected
10. h the fountain for 3 minutes and purge again If calcium or hard water deposits are forming on the panel or anywhere else in the system cycle CLR solution through the system until the deposits are removed then purge the system a few times with water TO FOUNTAIN If there are spots on the panel that dry out check that there are no blocked ports in the manifold tube Remove the three nuts that secure the tube cover and remove the cover Re move the tube by flexing it out in the centre This will allow the ends to pull out Poke the holes out T 3 with an opened paper clip and then flush the tube with water Clean the angled surface that the v TO DRAIN manifold sprays onto with liquid TSP or TSP substitute It is critical that this surface is extremely wa clean Install the tube back into the unit with the ports aiming straight down and refill with water f Install the tube cover and test the unit VALVE PURGE POSITION MANIFOLD TUBE ad as F ff f TUBE COVER The filter should be replaced every 3 4 months To replace unplug the pump Lay a towel under the filter housing as water will drain out of the housing when opening Unscrew the housing and remove the filter Replace with a new filter part N252 0001 available through your authorized NAPOLEON dealer Push the new filter firmly onto the collar in the bottom of the housing
11. he basin Be sure to not block or restrict in any way the pump s water inlet ELECTRICAL REQUIREMENTS The waterfall will require 2 separate 110 volt electrical receptacles one for the lights and one for the water pump GFI recepta cles must be used because of the use of water and possibility of contact It is not required that the receptacles be wired on their own circuit as the pump lights and optional UV light draw very little current If there is already a heavy load elsewhere on that circuit or you have trouble with breakers tripping a separate circuit will need to be installed Any circuit wiring or GFI installation must be done by a qualified electrician If you would like to be able to turn the fountain on and off the receptacles should be wired to a wall switch Two wall switched receptacles are recommended one for 4 the pump and UV light optional and one for the lights This will allow you to turn the lights on and off independently of the fountain INSTALLATION The framing dimensions are included in the framing specifications drawing The unit is designed to be installed after drywalling For added protection water resistant drywall green board or cement board are recommended in the vicinity of the fountain The fountain is designed to be attached to the studs over the drywall along both vertical sides of the fountain using drywall screws This will leave a basically flush surface to trim over Leak test the waterfall befo
12. in the unit to prevent dust and debris from the manufacturing process from entering the water Use caution when cleaning the grooves on the panel as the machined edges can be very sharp The acrylic panel is supplied with double sided tape which is used to attach the acrylic panel to the stainless steel panel Run three strips vertically down the panel one at each side and one down the centre Remove the backing and adhere the acrylic panel to the stainless panel Ensure that the bottom of the acrylic panel and the stainless panel are flush The acrylic panel will require more water to achieve the same wave effect as the stainless panel as the grooves will fill and retain water Again any dry spots can be removed by rubbing horizontally with a Scotchbrite pad 5 WF6 WF9 WF18 BACKBOARD PAIS OASHD BACKBOARD _ MORTAR 35 250 TILES 70 50 23 625 35 50 MORTAR CUSTOM SURFACE PANEL Panels can also be made using materials such as mirror glass slate marble or ceramic tile for display in your waterfall If tiling use waterproof cement board as a backer available at any building centre Cut the cement board to the size of your existing stainless steel panel Ensure that the tiles can be used in a wet environment Porce TILES lain tiles are recommended Tile the surface using thinset mortar as you would a ceramic tile floor or bathroom wall It is not necessary to leave a gap or grout line in yo
13. l panel provided with the waterfall is installed simply by sliding the top of the panel under the retaining bracket at the top of the waterfall and pushing it high enough to slip over the bottom support brackets The welded brackets that protrude at an angle from the waterfall housing merely provide pressure to the panel to prevent it from bowing The optional acrylic panel can be placed in front of the stainless steel panel in the same manner If building your own ceramic tile or slate background you must remove the stainless steel panel because ofthe thickness of the tile and cement board backing pARTS LIS ITEM WF6 PART WF9 PART WI18 PART PARTS DESCRIPTION 1 n010 0446 n010 0447 n010 0448 main housing x 2 n010 0449 n010 0450 n010 0451 water supply line assembly x 3 n432 0014 n432 0015 n432 0015 manifold x 4 n105 0008 n105 0008 n105 0008 rubber grommet x 5 n080 0169 n080 0170 n080 0170 water pinch bracket x 6 n450 0009 n450 0009 n450 0009 10 24 nut x 7 n402 0006 n402 0006 n402 0006 lighting track WF6 20 long WF9 18 32 long x 8 n402 0004 n402 0004 n402 0004 lighting track end cap x 9 n402 0005 n402 0005 n402 0005 lighting track pow er connection x 10 n402 0007 n402 0007 n402 0007 light socket x 11 n402 0003 n402 0003 n402 0003 light bulb x 12 n200 0071 n200 0072 n200 0072 light cover x n707 0002 n707 0002 n707 0002 12 volt transformer x 13 n255 0033 n255 0033 n255 0033 1 2 female pipe to 1 2 barb adapter fitting x 14 n160
14. me Warranty NAPOLEON may at its discretion fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part s NAPOLEON will not be responsible for the installation labour or any other costs or expenses related to the re installation of a warranted part and such expenses are not covered by this warranty Notwithstanding any provision contained in this President s Limited Lifetime Warranty NAPOLEON s responsiblity under this warranty is defined as above and it shall not in any event extend to any incidental consequential or indirect damages This warranty defines the obligation and liability of NAPOLEON with respect to the NAPOLEON waterfall and any other warranties expressed or implied with respect to this product its components or accessories are excluded NAPOLEON neither assumes nor authorizes any third party to assume on its behalf any other liabilities with respect to the sale of this product Any damages to the waterfall due to weather damage hail rough handling damaging chemicals or cleaners will not be the responsibility of NAPOLEON The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from NAPOLEON The warranty registration card must be returned within fourteen days to register the warranty or you can register on line at www napoleongrills com NAPOLEON reserves th
15. n streams of water with large dry spots in between Cleaning the panel with liquid TSP or TSP Substitute will remove any residue or film that is impeding the progress of the water Clean the panel thoroughly two or three times before the first use Before starting the waterfall the entire panel surface should be wet down either by spray bottle or wet cloth This will help the water to spread evenly across the panel The wave effect of water flowing down the panel will be attained after the panel is covered in water The wave pattern can be adjusted by increasing or restricting the flow of water with the valve at the side of the filter Adjust the valve to achieve the effect that is most pleasing to your eye Itis important to remember that too little water flow can cause dry spots to reappear on the surface of the waterfall You can increase the flow of water slightly until they disappear Lightly rubbing a wet cloth or Scotchbrite pad careful not to scratch the stainless steel surface across the panel may be enough to remove any dry spots l TO FOUNTAIN TO FOUNTAIN FROM BASIN iw TO DRAIN TO DRAIN VALVE VALVE FULL OPEN PARTIAL OPEN GROOVED ACRYLIC PANEL An optional grooved acrylic panel which enhances the ripple effect can be purchased at your authorized NAPOLEON dealer It is designed to be placed in front of the stainless steel panel This panel must be cleaned with liquid TSP or TSP Substitute before being placed
16. n255 0040 3 4 male pipe x 1 2 female pipe bushing x x standard x compris ac accessory ac accessoires 13
17. om that will not be covered by warranty If there is not a suitable water source to be had nearby the waterfall can be installed as a stand alone system but the water level will have to be monitored frequently and supplemented as needed WATER PUMPS The water pump supplied with your waterfall has been selected for its high flow volume efficiency quiet operation and reliability The pump is suitable for pushing water to a height of 12 feet however the flow is reduced greatly at that height This must be kept in mind when finding a location for the pump and water basin so the pump module must be located on the same floor as the fountain The system has a flow control valve after the filter that can be adjusted to provide the desired flow rate on the waterfall surface The pump must be kept submersed in water at all times while in operation The water acts as a cooling agent for the pump preventing the pump from overheating Low water levels frequently turning the pump on and off and impurities in the water from poor waterfall maintenance will shorten the life of the pump If maintained properly the pump will provide years of reliable service If you hear excessive noise coming from your pump check first to see that you have enough water in the basin to keep the pump fully submerged below 1 2 of water The pump should not be vibrating against the tub but if it is it can be isolated by placing a small piece of sponge between the pump and t
18. pump module is also required It should be located as close to the fountain as possible and in a location that is easily accessible for servicing and maintaining the module For every 1 foot that the pump module is located away from the fountain unit 1 inch of drop is required from the fountain basin drain outlet to the pump module drain inlet The waterfall is designed to be connected to a water source to automatically refill the basin as water evaporates and to a drain in case of accidental overflow The unit can be operated without the water source connection but is not recommended The water will evaporate naturally and will require additional water to ensure proper flow and pump operation Damage to the pump incurred by running dry is not covered by warranty The waterfall must be hooked up to a drain which will allow the tank to be purged for routine cleaning and will prevent the unit from overflowing if the float valve malfunctions Water damage to surrounding objects in your home is not covered in your NAPOLEON warranty The waterfall is designed to not splash however if it is not properly installed or maintained some splashing may occur Protect delicate nearby surfaces that could be damaged by splashing Do not trim with materials that can be damaged by moisture such as particle board or MDF It is best to install the unit in stone marble glass tile etc Although your NAPOLEON Waterfall will be beneficial to the air quality of your home
19. re fully enclosing All trim used on the fountain should be made of real wood not MDF or any other material that is not damaged by moisture with several coats of a water proof coating paint or urethane depending on the desired look The bottom piece of trim can only be nailed at the ends because it is mounted in front of the stainless basin It should be siliconed to the stainless basin for additional support After installing the fountain connect the piping as shown in the piping diagrams The tubing to connect the unit overflow to the house drain is not supplied If the unit is being connected to the water supply use an ice maker plumbing kit not supplied to connect the water supply to the float valve When the unit is operational adjust the float valve so that it turns the water off when the top of the pump is submerged below 1 2 of water Ensure that the wing nut on the side of the float valve is properly tightened Connect the light wire to the terminals on the transformer WATERFALL SURFACE MATERIALS The waterfall is supplied with a stainless steel panel for the water to flow over The surface of the stainless steel must be cleaned to remove any grease or oily materials left behind from the manufacturing process The protective coating will also leave a residue behind Any residue left on the surface or oily residue from your hands will repel the water and prevent a sheet of water from forming over the panel This will give you thi
20. stomer whose name appears on the warranty registration card filed with NAPOLEON provided that the purchase was made through an authorized NAPOLEON dealer and is subject to the following conditions and limitations This factory warranty is non transferable and may not be extended what so ever by any of our representatives The waterfall must be installed by a licenced authorized service technician or contractor Installation must be done in accordance with the installation instructions included with the product and all local and national building codes This limited warranty does not cover damages caused by misuse lack of maintenance hostile environments accident alterations abuse or neglect and parts installed from other manufacturers will nullify this warranty This limited warranty further does not cover any scratches dents rust painted finishes abrasive and chemical cleaners nor chipping on porcelain enamel parts nor any components used in the installation of the waterfall Should deterioration of parts occur to the degree of non performance within the duration of the warranted coverage a replacement part will be provided In the first year only this warranty extends to the replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions After the first year with respect to this President s Limited Lifeti
21. tions and ensure they are tight If leaking re tighten Water level too high Check that the basin drain is hooked up properly and not blocked preventing water from escaping Ensure that there is adequate drop from the fountain to the basin Also check that the float valve is working properly and not overfilling the basin Weld leaking in waterfall Inspect waterfall thoughly and ascertain exactly where the leak is coming housing from Drain all water and dry thoroughly Apply a bead of clear silicone to the inside surface of the weld Let stand 24 hours before re filling with water Water leaking out sides of Wipe the sides of the waterfall frame with an oiled WD40 rag to repel water waterfall Drain is gurgling Insufficient drop from Ensure there is at least 1 per foot drop from the fountain outlet to the basin fountain to basin inlet P trap created in drain line Ensure that there is a consistent slope from the fountain outlet to basin inlet with no dips that would trap water Certain drain configurations Reduce the flow through the flow control valve or loosen the white fitting in may have a tendency to the left hand drain loosen a couple of turns at a time and then test gurgle Water dripping from lip Decorative panel is not Remove the panel and flex out the panel tension springs Ensure positive of top retainer touching front lip of retainer tension on panel Replace the decorative panel ORDERING REPLACEMEN
22. ur tile Ensure that the 35 50 bottom edge of the tiles are flush with the bottom edge of the cement board You can choose any colour or pattern that you like to match the room or surroundings The water will flow over the tiles just as it does on the stainless steel panel but be sure to keep the edges of the tiles fairly flush to each other to prevent the water from splashing off Surfaces less than 3 8 thick such as glass or mirror can be installed in front of the stainless panel The stainless panel must be removed for all panels thicker than 3 8 up to a maximum of 3 4 Do not use glue to attach the tiles to the back panel as some types of glue or epoxy will leach out into the water causing the filter and manifold to plug CLEANING AND MAINTENANCE The waterfall should be drained and cleaned every 3 4 months possibly more depending on the quality of the water The water fall surface can be cleaned using a warm soap and water mixture Do not use harsh abrasive cleaners on the surface of the stainless steel panel or it will permanently scratch the surface Any wiping motion should be done in the direction of the grain If small scratches do occur they can be blended out by gentle rubbing in the direction of the grain with a Scotchbrite pad The water should be completely flushed and drained from the system switch the valve to the purge setting and run the pump to pump the water out Refill the tank run the water throug
23. water flow will be reduced over time We recommend that the filter be replaced whenever the waterfall is cleaned every 3 4 months or sooner as deemed necessary by poor water flow The filters can be purchased through your authorized NAPOLEON dealer The optional ultraviolet light will help destroy any green algae bacteria mould or mildew found in the water Flowing water is fairly resistant to this kind of growth but in time the water will become contaminated and the system will have to be flushed and thor oughly cleaned Not only unsightly but mould and bacteria growth will plug the manifold ports reducing the flow of water and can damage the water pump over time The optional UV light will help to keep your waterfall relatively maintenance free by keeping the water cleaner for a longer period of time The UV bulb must be replaced every year to ensure proper operation The UV bulbs are available from your authorized NAPOLEON dealer The waterfall is designed to be connected directly to a water source Waterfalls are natural humidifiers for the environment The amount of water the waterfall consumes daily is dependant upon how dry the air is and how large the waterfall surface is There is a float valve that will open as the water level drops allowing water to enter the system This will ensure that the water level is kept at the height required for proper operation of the water pump The pump should never be allowed to run dry and damage resulting fr
Download Pdf Manuals