Home
Napoleon Fireplaces EF30G User's Manual
Contents
1. 5 0 3 CONTROLS FOR ELECTRIC FIREPLACE Plug in your electric appliance FIGURE 5 0 3 Temperature Control Button Main ON OFF Power Switch and LED This switch is located on the right side of the control panel The indicates ON and O indicates OFF Heater LED When the appliance is first turned on the defe settings are as follows Ember bed HIGH TEMP f ruwe gy Flame HIGH Heater Appliance OFF Temperature Control Button and LED The Appliance LED is located to the right of the Remote Control ON OFF Power FLAME Button Push the TEMP button to cycle Receiver Button through different appliance settings Press and release the TEMP button to cycle through LO MED HI and OFF Each time the TEMP button is pushed the Appliance LED will change to its corresponding color Green for LO Orange for MED Red for HI and blank for OFF When the appliance is turned on heat will emit through the vents located in the middle of the top louvre panel The appliance has a built in thermostat so it will shut off automatically once the pre set temperature is reached It will also turn on automatically if the room temperature drops below the pre set temperature NOTE When the appliance is turned on for the first time it may release a slight harmless odour This odour is a normal occurrence caused by the initial heating of the internal heating elements and should not occur again Flame Control Button Flame Control Button
2. Inspect the bulbs inside the flame generation cylinder drum and replace them if necessary Ember bed is not Bulb s are burnt out Inspect the ember bed bulbs and replace them if necessary glowing or dimming Fireplace turns off Fireplace has overheated and Unplug the unit allow fireplace to cool for 10 minutes then and will not turn on safety device has caused the plug it back in termal switch to disconnect House circuit breaker has tripped Reset house circuit breaker Fireplace will not Fireplace is not plugged into an Check plug and plug it in come on when switch electrical outlet is flipped to ON Fireplace has overheated and Unplug the unit allow fireplace to cool for 10 minutes then safety device has caused the plug it back in thermal switch to disconnect Remote control does Low batteries Replace AA batteries in remote transmitter not work No warm air is Room temperature is higher Set fireplace to a higher temperature setting MED or HI coming out of the than the fireplace setting if it is fireplace set to LO or MED TP TROUBLE SHOOTING WARNING TP TROUBLE SHOOTING_ELECTRIC W415 0760 12 19 08
3. DDD DDD DDD DDD DDD DDD DDD DDD DDD DDD DDD DDD DDD DDD DDD DDD Power Cord and Thermostat 1 6 LOCATING APPLIANCE Back View Due to high temperatures this electric fireplace should be located out of traffic Keep combustible materials such as furniture pillows bedding papers clothes and curtains at least 3 feet 0 9m from the front of the fireplace Never locate this electric fireplace where it may fall into a bathtub or other water container Wear safety gloves and safety glasses for protection during installation and maintenance To prevent contact with sagging or loose insulation the electric fireplace must not be installed against vapor barrier or exposed insulation Localized overheating could occur and a fire could result Minimum clearance of 1 on all sides back and top must be TOP VIEW SHOWING APPROVED ROOM maintained at all times Illustrations throughout these instruc LOCATIONS OF FIREPLACE tions reflect typical installations and are for design purposes only Actual installations may vary slightly due to individual preferences Figure 1 6 illustrates a variety of ways the appliance may be located in a room The appliance may be installed directly on the floor uncarpeted or raised on a hearth 1 7 UNPACKING AND TESTING APPLIANCE Carefully remove the appliance from the box Prior to installing the appliance test to make sure the appliance operates properly by plugging the power supply cord into a
4. national and local electrical codes This appliance can be installed into either an existing appliance opening or as new construction renovation EXISTING APPLIANCE INSTALLATION Thoroughly clean out the existing appliance and hearth area Plan the power supply If an existing grounded outlet is near the appliance the power cord can run behind the appliance If the cord is not long enough to reach the outlet a grounded extension cord minimum AWG No 14 and rated to a minimum of 1875 watts may be used If you plan to cut or drill a hole in the existing appliance for wiring it is best to hire a professional to do this step in order to prevent personal injury MINIMUM CLEARANCE TO COMBUSTIBLES Sides back and top 1 NEW CONSTRUCTION OR RENOVATION 3 2 1 Select a location that is not prone to moisture and is located at least 0 9 m or 3 feet away from combustible materials such as curtains or drapes furniture bedding paper etc 3 2 2 Place the appliance in selected location to see how it will look in the future 3 2 3 Mark the desired location on the floor and store appliance in a safe dry and dust free location 3 2 4 Frame in an opening leaving at least 1 4 6 mm around the edge of the appliance Any new wiring must be done in compliance with local and national codes and other applicable regulations in order to reduce the risk of fire electric shock or other injuries Therefore it is strongly recommended that you hire a professional t
5. 2 4 0 FRAMING 13 4 1 HEARTH 14 4 2 COLD CLIMATE INSTALLATION 14 4 3 MINIMUM MANTEL CLEARANCES 14 4 4 FINISHING CHECKLIST 14 5 0 OPERATING INSTRUCTIONS 15 5 1 REMOTE CONTROL 16 6 0 MAINTENANCE 17 6 1 FLAME GENERATION BULB REPLACEMENT 17 6 2 EMBER BED BULB REPLACEMENT 18 6 3 CLEANING 18 7 0 REPLACEMENTS 19 N i 8 0 TROUBLESHOOTING 1 0 INTRODUCTION Do not operate fireplace before reading and understanding operating instructions Failure to operate fireplace according to operating instructions could cause fire or injury Risk of burns The fireplace should be turned off and cooled before servicing Do not install damaged incomplete or substitute components Do not burn wood or other materials in this fireplace Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition Supervise young children when they are in the same room as the fireplace Clothing or other flammable material should not be placed on or near the fireplace Due to high temperatures the fireplace should be located out of traffic and away from furniture and draperies Ensure you have incorporated adequate safety measure to protect infants toddlers from touching hot surfaces Even after the fireplace is out the glass and or screen will remain hot for an extended period of time Check with your local hearth specialty dealer for safety screens and hearth guards to protect children
6. INSTALLER LEAVE THIS MANUAL WITH THE APPLIANCE CONSUMER RETAIN THIS MANUAL FOR FUTURE REFERENCE TORO INSTALLATION AND quaLity FIREPLACES OPERATION INSTRUCTIONS Award Winning Products CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS CSA C22 2 No 46 UL 1278 CSA STANDARD EF30G ELECTRIC FIREPLACE CERTIFIED FOR CANADA AND UNITED STATES USING ANSI CSA METHODS SAFETY INFORMATION If the information in these instructions are not followed exactly an electrical shock or fire may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Wolf Steel Ltd 24 Napoleon Rd Barrie ON L4M 4Y8 Canada 705 721 1212 fax 705 722 6031 www napoleonfireplaces com ask napoleon on ca For customer service inquiries please call 1 866 592 6667 9 00am 5 00pm PST 10 00 W415 0760 12 19 08 TABLE OF CONTENTS 1 0 INTRODUCTION 2 1 1 WARRANTY 3 1 2 GENERAL INSTRUCTIONS 4 1 3 PRECAUTIONS 4 1 4 LISTING APPROVALS 5 1 5 DIMENSIONS 6 1 6 LOCATING APPLIANCE 6 1 7 UNPACKING AND TESTING APPLIANCE 6 3 0 ELECTRICAL REQUIREMENTS 7 3 1 GROUNDING APPLIANCE 7 3 3 HARDWIRE INSTALLATION 8 3 0 INSTALLATION 10 3 1 MINIMUM CLEARANCE TO COMBUSTIBLES 10 3 2 NEW CONSTRUCTION OR RENOVATION 10 3 3 INSTALLING THE APPLIANCE 11 3 4 GLASS EMBER INSTALLATION 11 3 5 THERMOSTAT AND THERMAL SENSOR INSTALLATION 1
7. This button is located to the right of the TEMP Button After power is turned on push the FLAME control button to adjust the flame and ember bed brightness Press and release the Flame Control Button to cycle through LO MED HI and OFF W415 0760 12 19 08 16 5 1 REMOTE CONTROL 5 1 1 5 1 2 5 1 7 Plug in your electric appliance REMOTE CONTROL FOR ELECTRIC FIREPLACE Make sure the appliance s main Power ON OFF button is at the ON positiqn The remote control will NOT work if the main Power button is at the OFF Infrared Ray Exit position Indicator When operating the remote control it must be directed towards the front Light of the appliance The button at the top left corner of the remote is the main ON OFF power button Pressing this button activates the power to the appliance To adjust the ember bed brightness press the or buttons To increase the ember bed brightness press the button to decrease the ember bed brightness press the button There are seven levels of brightness To activate the appliance press CC the button Press CC and release the button to cycle through LO MED HI and OFF Each time the button is pushed the Appliance LED will change to its corresponding colour Green for LO Orange for MED Red for HI and blank for OFF The appliance has a built in thermostat so it will shut off automatically once the pre set temperature is reached It will also turn on au
8. concerning prices and policies on replacement parts Normally all parts can be ordered through your Authorized dealer distributor FOR WARRANTY REPLACEMENT PARTS A PHOTOCOPY OF THE ORIGINAL INVOICE WILL BE REQUIRED TO HONOUR THE CLAIM When ordering replacement parts always give the following information e Model amp Serial Number of appliance e Installation date of appliance e Part number e Description of part e Finish IDENTIFIES ITEMS WHICH ARE NOT ILLUSTRATED FOR FURTHER INFORMATION CONTACT YOUR AUTHORIZED DEALER For aftermarket sales and service please call 1 866 592 6667 COMPONENTS REFNO EF90S DESCRIPTION O O OO fs woor REPLACEMENT GLASS EMBERS ACCESSORIES REF NO EFS0S DESCRIPTION W660 0081 DIGITAL THERMOSTAT W690 0001 MILLIVOLT THERMOSTAT NOTE Care must be taken when removing and disposing of any broken glass or damaged compo nents Be sure to vacuum up any broken glass from inside the appliance before operation Failure to position the parts in accordance with this manual or failure to use only parts specifically approved with this appliance may result in property damage or personal injury TP REPLACEMENTS W415 0760 12 19 08 20 8 0 TROUBLESHOOTING Turn off the fireplace completely and let cool before servicing Only a qualified service person should service and repair this electric fireplace SYMPTOM PROBLEM TEST SOLUTION Dim or no flame Bulb s are burnt out
9. conveniently located 120 Volt grounded outlet TP LOCATING APPLIANCE WARNING W415 0760 12 19 08 3 0 ELECTRICAL REQUIREMENTS 3 1 GROUNDING APPLIANCE This appliance is for use on 120 Volts The cord has a plug as shown in A of Figure 1 given below An adapter as shown in C is available for connecting three blade grounding type plugs to two slot receptacles The green grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box The adapter should GROUNDING METHODS METAL SCREW not be used if a three slot grounded receptacle is available COVER OF _ GROUNDED B To disconnect appliance turn controls to off then remove plug OUTLET BOX from outlet FIGURE 3 1 ADAPTER GROUNDING MEANS NOT ALLOWED IN CANADA W415 0760 12 19 08 8 3 3 HARDWIRE INSTALLATION Ensure all power is turned off before hard wiring this fireplace ELECTRIC DIAGRAM FIGURE 3 3 YOLOW Y4MO19 MSE Z MAAK YOLOW AWV14 IF YOU PUT IN THE TEMPERATURE MAIN CONTROL SENSOR ON THE WALL PLS CHOOSE 2 a 7 TEMPERATURE CONTROL SWITCH t 1 TEMPERATURE IF YOU USE THE SENSOR TEMPERATURE SENSOR PLS CHOOSE 1 RECEIVER If it is necessary to hard wire this appliance a qualified electrician may remove the cord connection and wire the appliance directly to the house hold wiring This appliance must be electrically connected and gro
10. e the risk of fire electric shock or personal injury Do not run cord under carpeting Do not cover cord with throw rugs runners or the like Arrange cord away from traffic areas and where it will not be tripped over RISK OF FIRE To prevent a possible fire do not block air intake or exhaust in any manner Do not use on soft surfaces where openings may become blocked RISK OF FIRE Do not blow or place insulation against the fireplace This electric fireplace is tested and listed for use only with the approved optional accessories Use of optional accessories not specifically tested for this electric fireplace could void the warranty and or result in a safety hazard If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors in the vicinity of this or any other fireplace This appliance must remain removable from the enclosure The appliance may be hardwired but it is recommended that it be plugged into a standard outlet using the supplied power cord This appliance must not be sealed around the front facing Fireplace vents located on the front and back of this electric fireplace cannot in any way be covered as it may create a fire hazard BEFORE INSTALLATION Select a suitable location that is not susceptible to moisture and is away from drapes furniture and high traffic areas NOTE Follow all
11. epresentatives Installation must be done in accordance with the installation instructions included with the product and all local and national building and fire codes This limited warranty does not cover damages caused by misuse lack of maintenance accident alterations abuse or neglect and parts installed from other manufacturers will nullify this warranty This limited warranty further does not cover any scratches dents corrosion or discoloring caused by excessive heat abrasive and chemical cleaners nor chipping on porcelain enamel parts mechanical breakage of PHAZER logs In the first year only this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions NAPOLEONE will not be responsible for installation labour or any other expenses related to the reinstallation of a warranted part and such expenses are not covered by this warranty Notwithstanding any provisions contained in the President s Limited Lifetime Warranty NAPOLEON s responsibility under this warranty is defined as above and it shall not in any event extend to any incidental consequential or indirect damages This warranty defines the obligations and liability of NAPOLEON with respect to the NAPOLEON electric fireplace and any other warranties expressed or implied with respect to this product it
12. es are manufactured under the strict Standard of the world recognized ISO 9001 2000 Quality Assurance Certificate NAPOLEON products are designed with superior components and materials assembled by trained craftsmen who take great pride in their work Once assembled the complete fireplace is thoroughly inspected by a qualified technician before packing to ensure that you the customer receive the quality product that you expect from NAPOLEON NAPOLEON ELECTRIC FIREPLACE PRESIDENT S LIFETIME LIMITED WARRANTY Electrical components and wearable parts such as fan heater motors switches nylon bearing components and remote controls are covered and NAPOLEON will provide replacement parts free of charge during the first year of limited warranty Light bulbs and fuses are NOT covered by the warranty Any labour related to warranty repair is not covered Construction of models vary Warranty applies only to components included with your specific heater CONDITIONS AND LIMITATIONS NAPOLEON warrants its products against manufacturing defects to the original purchaser only i e the individual or legal entity registered customer whose name appears on the warranty registration card filed with NAPOLEON provided that the purchase was made through an authorized NAPOLEON dealer and is subject to the following conditions and limitations This factory warranty is non transferable and may not be extended whatsoever by any of our r
13. from hot surfaces These screens and guards must be fastened to the floor Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace It is imperative that the control compartments circulating blower and its passageway in the fireplace and are kept clean The fireplace should be inspected before use and at least annually by a qualified service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc The fireplace area must be kept clear and free from combustible materials gasoline and other flammable vapors and liquids Under no circumstances should this fireplace be modified Do not use this fireplace if any part has been under water Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system which has been under water Do not operate the fireplace with the glass door removed cracked or broken Replacement of the glass should be done by a licensed or qualified service person Do not strike or slam shut the fireplace glass door Keep the packaging material out of reach of children and dispose of the material in a safe manner As with all plastic bags these are not toys and should be kept away from children and infants NOTE Changes other than editorial are denoted by a vertical line in the margin TP ELECTRIC WARNING W415 0760 12 19 08 1 1 WARRANTY NAPOLEONG electric fireplac
14. ir intakes or exhaust in any manner Do not use on soft surfaces like a carpet where openings may become blocked 1 3 12 Use this appliance only as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons 1 3 13 Avoid the use of an extension cord because the extension cord may overheat and cause a risk of fire However if an extension cord must be used the cord shall be No 14 AWG minimum size and rated not less than 1875 watts SAVE THESE INSTRUCTIONS LISTING APPROVALS This appliance has been tested in accordance with the CSA Standards for fixed and location dedicated electric room appliances in the United States and Canada If you need assistance during installation please contact your local dealer NOTE This appliance must be electrically wired and grounded in accordance with local codes or in the absence of local codes with National Electric Code ANSI NFPA 70 latest edition or the Canadian Electric Code CSA C22 1 as appropriate Appliance 30 762mm Width Appliance 32 29 820mm Height Appliance 11 02 280mm Depth Net Weight 77 lbs 35kgs Gross Weight 83 8 Ibs 38kgs W415 0760 12 19 08 6 1 5 DIMENSIONS FIGURE 1b Heater vents DO NOT COVER 32 250 FIGURE 1a Rating Plate and Serial Number T 30 375 FIGURE 1d Heater vents and air openings can not be covered in any circumstances
15. l of a home This will ensure that clearance to combustibles is maintained within the cavity 4A W415 0760 12 19 08 14 4 1 HEARTH A hearth is NOT necessary but is recommended for aesthetic purposes 4 2 COLD CLIMATE INSTALLATION It is MANDATORY to have an insulated wall behind the fireplace when the fireplace is being installed on an outside wall or chase 4 3 MINIMUM MANTEL CLEARANCES Risk of fire maintain all specified air space clearances to combustibles Failure to comply with these instructions may cause a fire or cause the appliance to overheat Ensure all clearances i e back side top vent hearth mantel front etc are clearly maintained When using paint or lacquer to finish the mantel the paint or lacquer must be heat resistant to prevent discolouration The minimum distance from me top of the appliance that the FIGURE 4 3 V7 mantel can be installed is 10 at any depth ee MANTEL y WALL mm m FIREPLACE FRONT SIDEVIEW GLASS OPTIONAL HEARTH r r r TF 4 4 FINISHING CHECKLIST 4 4 1 Power supply service must be completed prior to finishing to avoid reconstruction 4 4 2 Appliance vents and air openings cannot be covered in any circumstances TP COLD CLIMATE WARNING TP MINIMUM MANTEL CLEARANCES WARNING W415 0760 12 19 08 15 5 0 OPERATING INSTRUCTIONS The controls are located on the bottom right corner of the appliance 5 0 1 5 0 2 5 0 3
16. ns before using this appliance 1 3 2 This appliance is hot when in use To avoid burns do not let bare skin touch hot surfaces If provided use handles when moving this appliance Keep combustible materials such as furniture pillows bedding papers clothes and curtains at least 3 feet 0 9 meters from the front of the appliance and keep them away from the sides and rear 1 3 3 Extreme caution is necessary when this appliance is used by or near children and whenever the appliance is left operating and unattended 1 3 4 Always unplug appliance when not in use TP ELECTRIC GENERAL INSTRUCTIONS WARNING W415 0760 12 19 08 1 4 5 1 3 5 Do not operate this appliance with a damaged cord or plug after the appliance malfunctions has been dropped or damaged in any manner Return appliance to authorized service facility for examination electrical or mechanical adjustment or repair 1 3 6 Do not use outdoors 1 3 7 This appliance is not intended for use in bathrooms laundry areas and similar indoor locations Never locate appliance where it may fall into a bathtub or other water container 1 3 8 To disconnect appliance turn controls to off then remove plug from outlet 1 3 9 Connect to properly grounded outlets only 1 3 10 Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or fire or damage the appliance 1 3 11 To prevent a possible fire do not block a
17. o complete any such work TP INSTALLATION WARNING W415 0760 12 19 08 11 3 3 INSTALLING THE APPLIANCE 3 3 1 Once the site has been prepared the appliance can be installed 3 3 2 Make sure the main power switch is in the OFF position 3 3 3 Plug the appliance into a 15 amp 120 Volt grounded outlet Use a CSA or UL approved surge protector 3 3 4 Push in the appliance so that the trim is against the finished mantel or wall surface 3 4 GLASS EMBER INSTALLATION Glass front must be removed and the fireplaces must be installed in it s final location before the glass embers are installed 3 4 1 To remove the glass front remove the two bottom screws as illustrated below 3 4 2 Lift the front up and pull forward and off Set the front in a location where it will not be Knocked over or damaged 3 4 3 Carefully distribute the glass embers into the bottom tray on the front of the appliance as illustrated 3 4 4 Re install the glass front using the two securing screws BOTTOM TRAY 2 SCREWS TP GLASS EMBER WARNING W415 0760 12 19 08 12 3 5 THERMOSTAT AND THERMAL SENSOR INSTALLATION This appliance has two options for heat control First is a thermal controlled sensor which comes plugged into the appliance beside the main power cord This sensor has no user temperature set points it will turn off the heater when the sensor reaches its pre set point and will only turn the heater back on when it has c
18. ooled back down below this set point On the low setting green light the set point is 16 C 61 F on medium orange light 22 C 72 F and on high red light 28 C 82 F This small sensor can be placed anywhere in the room within the length of the sensor wire but it should not be placed near the top or front of the appliance Placing the sensor too close to the heater area of the appliance will cause unwanted cycling of the heater Second is the option of a wall mounted thermostat Napoleon Part W690 0001 W660 0081 or an equivalent low voltage thermostat A wall thermostat can be used in place of the thermal control sensor You must first remove the sensor by unplugging it from the right side of the appliance beside the main power cord Replace the sensor with the wire harness provided in the manual baggie Plug it into the appliance and connect the other end to the thermostat The thermostat should be placed as per the thermostat installation instructions FIGURE 3 5a FIGURE 3 5b W415 0760 12 19 08 13 4 0 FRAMING TOP VIEW SHOWING APPROVED ROOM LOCATIONS OF FIREPLACE FIGURE 9 Se L ees gt FIGURE 10 zji CZN lt I 11 a Sipe ST NOTE In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the appliance body it is recommended that the walls of the appliance enclosure be finished ie dry wall sheetrock as you would finish any other outside wal
19. r use only with the optional accessories listed in these instructions Use of optional accessories not specifically tested for this electric fireplace could void the fireplace warranty and or result in a safety hazard Risk of electric shock No user serviceable parts inside High temperature risk of fire Keep electrical cords drapery furnishings and other combustibles at least 3 feet 0 9m from the front of the fireplace and away from sides and rear Do not use damaged electrical cords Servicing should be done only while the fireplace is disconnected from the power supply circuit This electric appliance meets the construction and safety standards of H U D for application in manufactured homes when installed according to theses instructions 1 2 1 Prior to plugging your appliance into an electrical outlet verify that the house circuit breakers for the outlet are on 1 2 2 The appliance may emit a slight harmless odour when first used This odour is normal and it is caused by the initial heating of internal appliance elements and will not occur again 1 2 3 If your appliance does not emit heat consult the operation section of this manual for further information 1 2 4 Use with a CSA or UL certified surge protector 1 3 PRECAUTIONS When using electric appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following 1 3 1 Read all instructio
20. rated life There are a total of 8 halogen light bulbs Type GX6 35 rated 120Volts 35Watts in FIGURE 6 1 1 BACK PLATE Mantel Back View of Insert 2 Screws 2 Screws On The s i On The Side 3 Screws On Side The Back Flame Generation Cylinder Drum I eedeeeed 1 P N Screw FIGURE 6 1 2 TP MAINTENANCE WARNING W415 0760 12 19 08 18 6 2 6 3 Remove spring clip Hold socket and pull out old bulb Hold socket and push in new bulb DO NOT exceed wattage Replace spring clip Repeat steps 3 and 4 for the second bulb Insert bottom edge of removed cylinder half into bottom drum track Gently squeeze drum cylinder until its top edge fit into top drum rack Reattach the screw that was previously removed Secure the backplate to the main appliance by reattaching the 7 screws removed EMBER BED BULB REPLACEMENT 6 2 1 6 2 2 6 2 3 6 2 4 6 2 5 6 2 6 Remove the 7 screws from the bottom BACK PLATE half of the back of appliance as illustrated Remove back plate Mantel Back View of Insert Locate the ember bed bulbs which are underneath the flame generation cylinder drum 2 Screws OnThe Side Ne DDD 000 000 DOD DDD 000 000 DDD DOD 000 000 DDO DDD DDD DDD DOD DDD DDDIDDD DDD Remove spring clip Hold socket and pull out old bulb Hold socket and push in new bulb DO NOT exceed wattage or handle wi
21. s components or accessories are excluded NAPOLEON neither assumes nor authorizes any third party to assume on its behalf any other liabilities with respect to the sale of this product Any damages to fireplace brass trim or other component due to water weather damage long periods of dampness condensation damaging chemicals or cleaners will not be the responsibility of NAPOLEON The bill of sale or copy will be required together with a serial number and a model number when making any warranty claims from your authorized dealer The warranty registration card must be returned within fourteen days to register the warranty NAPOLEONG reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON GOING PRODUCT IMPROVEMENTS NAPOLEON IS AREGISTERED TRADEMARK OF WOLF STEEL LTD PATENTS U S 5 303 693 801 CAN 2 073 411 2 082 915 WOLF STEEL LTD TP ELECTRIC WARNING W415 0760 12 19 08 4 1 2 GENERAL INSTRUCTIONS Read these instructions completely before beginning installation Failure to follow them could cause a fireplace malfunction resulting in serious injury and or property damage All electric fireplaces have hot and arcing or sparking parts inside Do not use it in areas where gaso line paint or flammable liquids are present This electric fireplace is tested and listed fo
22. s in your appliance have burned out you will notice one or more of following COMMON OBSERVED PROBLEMS There is no flame Flame or Ember bed is dim or dark in certain areas Flame is not moving or glowing BULB TYPE GX 6 35 120V 35W B pcs included Mlaxirmurmi your appliance 2 bulbs provide illumination for the ember bed 2 bulbs provide illumination for flame generation 4 extra bulbs for replacement FIGURE 6 0 FLAME GENERATION BULB REPLACEMENT 6 1 1 6 1 2a 6 1 2b 6 1 2c Remove the 7 screws from the bottom half of the back of appliance as illustrated Remove back plate Locate the flame generation cylinder drum It is constructed of two removable halves They are two 2 matte black sheet metal pieces with holes in them either of which can be removed from the appliance Remove the screw as illustrated that are used to secure the flame generation cylinder drum Squeeze half of drum cylinder until its top edge clears the top drum track Remove the bottom edge of the cylinder drum from the bottom drum track This will give you access to the light bulbs NOTE Do not exert excessive pressures on the drum cylinder as this may cause damage FLAME GENERATION CYLINDER Your appliance appliance must be opened in order to replace the light bulbs To reduce the number of times you need to open the appliance replace all bulbs at the same time if they are close to the end of their
23. th bare hands Repeat steps 3 and 4 for the second bulb Secure the back plate to the main appliance by reattaching the 7 screws that were previously removed CLEANING 6 3 1 The glass is cleaned in the factory during assembly During shipment installation handling etc the glass surface may collect dust particles These can be removed by buffing lightly with a clean dry cloth 2 Screws n OnThe Side 3 Screws On Tt The Back FIGURE 6 2 1 FIGURE 6 1 2 FLAME GENERATION CYLINDER DRUM Flame Generation F Ani Drum Squeeze DRUM BULB REPLACEMENT Bulbs with Flame Generation spring Clips Cylinder Drum FIGURE 6 1 6 LOCATE THE EMBER BED BULBS Flame Generation Cylinder Drum EMBER BED BULB REPLACEMENT FIGURE 6 2 4 6 3 2 To remove fingerprints or other marks the glass can be cleaned with a damp cloth using a good quality household glass cleaner The glass should be completely dried with a lint free cloth or paper towel 6 3 3 In the event of glass breakage vacuum all remaining glass pieces with a shop vac DO NOT VACUUM WHILE PIECES ARE HOT Replace glass only with replacement part specifically for this appliance Never substitute material Only fully tempered safety glass may be used on this appliance W415 0760 12 19 08 19 7 0 REPLACEMENTS Contact your dealer or the factory for questions
24. tomatically if the room FIGURE 5 1 temperature drops below the pre set temperature To adjust the height of the flame press the or buttons To increase the height of the flame press the button to decrease the height of the flame press the button There are seven levels of flame effects To turn off the appliance press the ON OFF button once NOTE This remote control must remain within 8 meters or 26 feet of the appliance to be effective Make sure your batteries are fully charged and installed correctly in your remote control W415 0760 12 19 08 6 0 MAINTENANCE 6 1 17 Always disconnect the power and allow the electric fireplace to cool before performing any cleaning maintenance or relocation of this electric fireplace Turn controls to OFF and remove plug from outlet or turn off the house circuit breaker to electric fireplace receptacle Do not install replacement bulbs that exceed specified maximum watts The halogen light bulbs in your unit can become extremely hot Allow at least 10 minutes between turning off the fireplace and removing the light bulbs to avoid accidental burns Do not handle the lamp bulbs with bare fingers oils from your skin will damage the bulbs whey they heat up Use gloves ora clean dry cloth when handling bulbs Most halogen light bulbs are rated to last approximately 1800 hours Like all light bulbs halogen bulbs require periodic replacement When the bulb
25. unded in accordance with local codes if hard wired In the absence of local codes use the current CSA C22 1 CANADIAN ELECTRICAL CODE in Canada or the ANSI NFPA 70 1996 NATIONAL ELECTRICAL CODE in the United States TP HARDWIRE WARNING W415 0760 12 19 08 3 3 1 Remove cover plate located beside the power cord to reveal the 7 8 wire hole Discard cover plate screws and insert a box connector into the hole 3 3 2 Remove the lower back panel from the appliance to expose wiring FIGURE 3 3 3 Remove 2 screws on cover plate 3 3 3 Remove the power cord strain relief from the side of the appliance and cut the cord where shown below This F will be the hardwire us connection point de on O70 0 BE Box Connector 3 3 4 Feed the supply wires through the box connector and the grommet 3 3 5 Using wire connectors connect the common white wires together then the hot black wires and then the ground green wires 3 3 6 Ensure the newly connected wires are kept away from the rotating parts and the circuit board and re install the back panel NOTE This appliance must be serviced from the back leave enough wire so that the appliance can be removed from the enclosure without disconnecting the power supply wires W415 0760 12 19 08 10 3 0 INSTALLATION 3 1 3 2 RISK OF FIRE The power cord must not be pinched against a sharp edge Secure cord to avoid tripping or snagging to reduc
Download Pdf Manuals
Related Search
Related Contents
Samsung MAX-KT65 Kasutusjuhend Samsung NP-P510 User Manual (Vista/Windows7) Owner's Manual 取扱説明書 Bedienungsanleitung Mode d'emploi Beyem M-15 Philips myLiving Copyright © All rights reserved.
Failed to retrieve file