Home
Napoleon Fireplaces 1600C-1 User's Manual
Contents
1. A 22 in Minimum clearance must be maintained from combustible wall to the chimney connector Double walled connectors listed for a minimum clearance of 12 or less from combustible materials must be used to achieve the following clearances Flue configuration Type 2 Horizontal Vertical A 16 16 FROM UNIT B 14 14 C 15 15 D 25 25 FROM 7 PIPE E 18 INSTALLATION WHEN INSTALLED WITH BLOWER KITEP63 For reduced clearances installation must comply with NFPA 211or CAN CSA B365 Alcove installation Model 1600C 1 may be installed into an alcove having a depth of not more than 4 feet and a height of at least 7 feet when using a listed double wall connector that is rated for a minimum 12 clearance to combustible material The minimum clearances are as shown Alcove installation 84 4 foot max Illustrated with 75 hearth pad Walls shall not extend from front of unit when installed in the alcove configuration Stove installation If the stove is to be installed ona combustible floor it must be placed on a approved non combustible hearth pad 8 8 that extends 8 200mm beyond the stove sides and back and 18 455mm to the 18 front Listed single wall chimn
2. Flue configuration Type 1 Horizontal Vertical A 406 mm 406 mm DU F PO LE B 559 mm 559 mm C 381 mm 381 mm 635 mm 635 mm DU CONDUIT E ie 559 mm Une distance minimum de 559 mm sera maintenue entre le mur combustible et le raccord de chemin e Afin d obtenir ces mesures de d gagement il faut utiliser des raccords double parois homologu s pour une distance de 305 mm ou moins par rapport aux mat riaux combustibles Flue configuration Type 2 Horizontal Vertical A 406 mm 406 mm DU POELE B 356 mm 356 mm C 381 mm 381 mm D 635 mm 635 mm abe E 406 mm CONDUIT INSTALLATION AVEC LE KIT SOUFFLERIE EP63 Les installations avec des d gagements r duits doivent se conformer aux normes NFPA211 ou CAN CSA B365 Installation dans une alc ve Le mod le 1600C 1 peut tre install dans une alc ve de profondeur inf rieure 122 mm et d une hauteur d au moins 213 mm quip d un conduit mural double enveloppe homologu pos une distance minimum de 305 mm des mat riaux combustibles Les distances minimum sont comme indiqu Installation dans une alc ve 213 mm f Illustr avec protection au sol de 19 mm 75 122 mm max Les murs ne doivent p
3. Fire extinguishers smoke detectors All homes with a solid fuel burning fireplace should have at least one fire extinguisher in a central location known to all and at least one smoke detector in the room containing the fireplace Ifit sounds an alarm correct the cause but do not deactivate or relocate the smoke detector Fuel loading and burn cycle For maximum efficiency when the stove is thoroughly hot load it fully to the top of the door opening and burn at a medium low setting Maximum heat for minimum fuel optimum burn occurs when the stove top temperature is between 500 F 260 C and 600 F 315 C The cleanness of the glass is a good indicator of your operating efficiency Not enough heat is produced when only one or two pieces of wood are burned or the wood may not burn completely A minimum of three pieces are needed to encase a bed of coals that sustains the fire Loosely stacked wood burns quicker than a tightly packed load Wood burns in cycles rather than giving a steady output of heat It is best to plan these cycles around your house hold routine so that only enough coals are left to start the next load In the evening load your stove atleast a half hour before bed to ensure a good fire hot enough to close the draft control for an overnight burn Burn only dry seasoned wood It produces more heat and less soot or creosote Do not burn ocean beach wood Its salt content can produce a metal eating
4. Ca SECURING Y o lt 1 BRACKETS Voies Sie a E N z CA STUD fe n RETAINER Ed EN ES S VENT O CONNECTOR When installing the 1600C 1 in a mobile home use the 111KT Outside air kit in conjunction with the 113KT Outside Air Adaptor Kit Remove the two screws from the bottom of the unit and install the two floor securing brackets using the two screws removed Install the vent connector by inserting the stud retainer into the hole in the bottom of the fireplace Position the retainer so that the studs come through the holes indicated Hold the retainer in place and align the holes in the vent connector with the studs of the retainer Secure the vent connector in place using the 2 nuts supplied Secure the unit to the floor using the securing brackets and the two 10x1 5 screws supplied Hardware included Qty Description 1 2 10x1 5 screws 2 2 nuts 3 1 stud retainer nf 10 Bl 4 OPERATING INSTRUCTIONS WARNING Objects placed in front of the fire place should be kept a minimum of 48 from the front face CAUTION Never use gasoline gasoline type lantern fuel kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire in this heater Keep all such liquids well away from the heater while it is in use Your Napoleon EPA listed product is a Hi Tech unit designed with the most advanced technology The
5. Pix Se is Nix ss Pa s 01 8 252674 Grat cover fait e ik etats DU AU AS a Peis ioe te ad N Eh us 01 9 309233 EF Grat M ERA A es A e et ra Pd ts N ESS 01 10 322718 EF Air channel cover Pix Das Nit Poenat 01 11 330018 EF Hearth plate Pots Nuts Ela 01 12 105275 Ceramic brick liner Pin N S ne Es 01 13 306285 EF Back panel Pog Be dks N ge Poemas 01 14 331001 EF gt Adaptoti ns tan a ae E A Bae Pi es Nate Ela ses 01 15 303826 EF Flue collar Pire N ESS 01 16 157968 Rating plate Pos is Noa Eta de 01 17 310734 RJ Right side panel Es es 01 17 310734 EF Right side panel Peas PAR a Rs 01 17 310734 77 Right side panel Na ot oe Oe due 01 18 305214 EF Liner right side Pee elie ous N El es 01 19 319738 EF Grate support Inner base Pre Ni ru ASE 01 20 332000 EF Air duct left side Pix SP bas Nee ou Eire 01 21 315610 EF Air duct right side Bi rs N Fa es 01 22 270411 00 Air control damper Pre NE nu ANNE 01 23 236131 00 Sealing plate Pos SP boss Nuit ou Fire 01 24 300491 EF Base ass ae a Lens A t ek Pise Nudo Fat es 01 25 359806 RJ Frontiplate s een Ad O RE A Nu Fe 01 25 359806 EF Frontplate s 2 obrar ta
6. INSTRUCTIONS D OP RATION AVERTISSEMENT Objects placed in front of the fire place should be kept a minimum of 48 from the front face ATTENTION N utilisez jamais d essence d huile lampe de k ros ne d essence briquets ou autres liquides similaires pour allumer ou raviver un feu dans cet appareil Gardez tous ces liquides loin du po le lorsqu il est en fonction Votre appareil Napol on certifi aux normes EPA est une unit de haute technologie con ue selon les principes technologiques les plus avanc s Cet appareil est extr mement herm tique et est quip d une alimentation directe d air comburant exclusive ensemble optionnel un dispositif de s curit qui emp che les coulements afin de garder votre maison exempte de monoxyde de carbone advenant un refoulement de chemin e ou une pression n gative interne Lors du premier allumage Le po le mettra une l g re odeur pendant quelques heures C est un tat provisoire normal provoqu par la combustion des peintures internes et des lubrifiants utilis s dans le processus de fabrication et ne se produira plus par la suite Ouvrez simplement une fen tre pour a rer suffisamment la salle pendant les premi res heures de fonctionnement Pour commencer un feu vif est n cessaire Placez du papier chiffonn sur la grille et couvrez de bois d allumage Ouvrez la commande d air enti rement en la d pla ant vers la droite Allumez le papier et l
7. begin Also check with the chimney connector manufacturer for any specific requirements Consult with your dealer va d regarding special Y ESE This is the preferred connection components x method of passing a flue pipe through a combustible available for use for wall D a et pass throughs Use only parts that have been tested and listed for use in a wall pass through Heat shield installation The heat shield stored in the unit must be installed under the stove with 2 provided screws Please see page 8 to respect the orientation of the heat shield MOBILE HOME INSTALLATION MODEL 1600C 1 IS APPROVED FOR INSTALLATION IN MOBILE HOMES IN BOTH CANADA AND THE UNITED STATES The stove must be secured to the floor of the mobile home Warning Do not install this stove in a bedroom sleeping room Do not install the stove in any way that might compromise the structural integrity of the mobile home floor walls ceiling or roof Venting Connect the stove to a chimney system using a listed double wall connector with a minimum clearance rating of 12 or less Use chimney system listed to ULC S629 in Canada or UL103HT in the USA The chimney must be installed in accordance with the manufacturer s instructions Use only specified components with no substitutions The chimney and pipe must extend at least 8 feet above the stove and 3 feet above the highest point of
8. Un tuyau fum e non isol ne doit pas traverser un grenier un entre toit un placard ou autre endroit dissimul similaire ou traverser un plancher un plafond un mur ou une cloison ou toute autre construction combustible N UTILISEZ AUCUN MAT RIAU DE FORTUNE DURANT L INSTALLATION 1 Posez le po le en position Rep rez le centre du tuyau de fa on ne pas avoir si possible couper les soliveaux Utilisez un fil plomb pour aligner le centre du tuyau 2 D coupez et charpentez une ouverture dans le toit Un d gagement minimal de 2 entre la chemin e et les mat riaux combustibles doit tre maintenu NE REMPLISSEZ CET ESPACE D AUCUN MAT RIAUX Des boutisses devraient tre plac es entre les soliveaux et clou es en place pour assurer un support additionnel Pour tout plancher ou plafond travers par la chemin e les espaceurs coupe feu doivent tre fix s la base de la charpente de louverture 3 D terminez les dimensions de louverture d couper dans le toit l aide d un fil plomb Dessinez l ouverture 2 plus grande sur tous les c t s que le diam tre de la chemin e afin de conserver les d gagements ad quats Ajout de sections de chemin e Ajoutez des sections de chemin e selon les instructions d installation du fabricant autant qu il est requis pour atteindre la hauteur voulue Le sommet de la chemin e doit d passer d au moins 3 pieds le point o la chemin e merge du toit
9. 4 4 4 Lu eA eee ee es Nils aus de bs 01 Clou cannel 6X30 Pise Now band PR 04 Tresse c ramique DIAM6 PL ES N Bie 2m Verre n oc ramique 278 X 220 Bi bus 8 Ni 4 5 44 ZETTE 02 Patte fixation Pa ss Ni sis Free as 08 JONE 2p at tae fe ae Mentos eee see ee teat onde eds Re or tere Bee N Fr 08 Poign e crochet Pig Ni 4 5 44 TETEE 01 Axe de fermeture Poca es Ni e Exts 01 Tresse c ramique DIAM15 Pot wee N F 1 64m Tresse c ramique DIAM10 Pos dew 4 5 4 N 22224 F 1 33m Tresse c ramique DIAM7 Poca os Nooo F 3 16m SOME PCS La Mk sr eed a ke desk Re tee oe N F2 1m Gant s acs eus had as da eka ad Pris sa N 4 2 4 Fe adad 01 Souffleri s 24 00 eG eaea e ea arte Ge a a Po Ya Nue F Pare tincelles Por 2 N F Adaptateur pour prise d air ext rieur Pumas Nix sua F Ensemble prise d air ext rieur Poda ah eS EE F 13 14
10. retirez les vis et les supports qui retiennent la vitre Enlevez toute la vitre bris e Remplacez le joint si n cessaire Placez ensuite la nouvelle vitre en position et remplacez les vis et les supports INSTALLATION Les installations avec des d gagements r duits doivent se conformer aux normes NFPA211 ou CAN CSA B365 Pour les d gagements avec le kit EP63 install se r f rer la page 6 Installation dans une alc ve Le mod le 1600C 1 peut tre install dans une alc ve de profondeur inf rieure 122 mm et d une hauteur d au moins 213 mm quip d un conduit mural double enveloppe homologu pos une distance minimum de 305 mm des mat riaux combustibles Les distances minimum sont comme indiqu Installation dans une alc ve 213 mm 122 mm max Illustr avec protection au sol de 19 mm 75 Les murs ne doivent pas se prolonger devant la facade de l appareil lorsque install dans une alc ve Installation du po le Si le po le est install sur un plancher combustible il doit tre plac sur un protecteur de plancher incombustible approuv qui doit d passer les c t s et l arri re du po le de 203 mm et se prolonger de 457 mm sur le devant 203 mm O 203 mm 203 mm 457 mm CE W OER XXI RSS RAS Ow DEAR XY Y Raccord simple paroi
11. un incendie ou un feu de chemin e AVERTISSEMENT PROPOSITION 65 DE LA CALIFORNIE L utilisation de cet appareil peut produire de la fum e qui contient des substances chimiques qui selon l tat de Californie causeraient le cancer des malformations cong nitales ou autres dangers pour la reproduction Soin de la vitre Si vous ne nettoyez pas le d p ts r guli rement la vitre risque de rester marqu e en permanence Normalement un feu tr s chaud maintiendra la vitre propre Les raisons les plus fr quentes pourquoi la vitre se salit incluent trop peu de combustible est utilis alors le po le ne se r chauffe pas compl tement du bois vert ou humide est utilis le contr le de tirage est trop ferm il n y a alors pas suffisamment d air pour r aliser une combustion compl te S il est n cessaire de nettoyer la vitre utilisez des linges doux sans abrasifs NETTOYEZ SEULEMENT LORSQUE LA VITRE EST FROIDE La vitre est tr s r sistante mais ne laissez pas le bois en combustion s appuyer contre la vitre Fermez toujours la porte doucement Si la vitre devait craqueler pendant que le feu br le n ouvrez pas la porte jusqu ce que le feu s teigne et n utilisez pas l appareil jusqu ce que la vitre ait t remplac e pr f rablement par votre d taillant par une nouvelle plaque de verre c ramique de 4 mm d paisseur N UTILISEZ PAS DE SUBSTITUT Pour enlever la porte ouvrez la et soulevez la
12. ESS 01 16 157968 Plaque signal tique Poa Sot N Foardat 01 17 310734 RJ Cot diot LR a a E ee ee o A Es es 01 17 310734 EF C t droit Peas PAR a Rs 01 17 310734 77 Cote droit 4 2 dog a te ban Les Ra at hs A Na ot oe Oe due 01 18 305214 EF Brique droite Pee elie ous N El es 01 19 319738 EF Support grille Pre N Es 01 20 332000 EF Suppl ment conduit Pix 22 24 Nee Le Pe tin at 01 21 315610 EF Conduita et ie ea ie ane es Pot N Fa es 01 22 270411 00 Clapet d air Prises N Fes 01 23 236131 00 Plaque obturation Pix e Ne Le Podha 01 24 300491 EF DESSOUS unta ai eg A E Pot Nudo Fat es 01 25 359806 RJ AA AA EA A IA AER NE tira 01 25 359806 EF Fa ade sle p22 ad a Pis posi trae ad 01 25 359806 77 Facade ia lee ed DN neue os 01 26 327905 RJ Suppl ment dessous Fe 01 26 327905 EF Suppl ment dessous Pis aa adat di miens dires 01 26 327905 77 Suppl ment dessous N ES ok a ace 01 27 158627 Poign e ressort Prat NE ob Et 01 28 179624 Tige de commande Pix 22 a Ne Le FY hin ae 01 29 331700 Compl ment cendrier Peete ne N Fate te 01 30 624045 00 Corps cendrier Pare Nix se Ei da 01 31 262611 cran de dessous Pott
13. Is the smoke flow impeded by too long a horizontal pipe or too many bends Is it a weak draft perhaps caused by a leaky chimney a cold outside chimney too short a chimney ora chimney too close to trees or a higher roof Creosote formation and removal When wood is burned slowly it produces tar and other organic vapours which combine with expelled moisture to form creosote These vapours condense in the relatively cooler chimney flue of a slow burning fire and when ignited make an extremely hot fire So the smoke pipe and chimney should be inspected monthly during the heating season to determine if a buildup has occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire Runaway or chimney fire Runaway fires can be the result of two major factors 1 Using incorrect fuel or small fuel pieces which would normally be used as kindling 2 Leaving the door ajar too long and creating extreme temperatures as the air rushes in the open door Solutions 1 Do not burn treated or processed wood coal charcoal coloured paper or cardboard 2 Be careful not to over fire the unit by leaving the door open too long after initial start up A thermometer on the chimney connector and or stove top helps What to do if a runaway or chimney fire starts 1 Close the draft fully 2 Call local fire department 3 Examine flue pipes chimney attic and roof of the house to see if any part has become
14. STOVE THERMOMETER OFFERS A GUIDE TO PERFORMANCE Can t get the stove going Use more kindling and paper Assuming the chimney and vent are sized correctly and there is sufficient combustion air the lack of sufficiently dry quantities of small kindling is the problem Thumb size is a good gauge for small kindling diameter Can t get heat out of the stove One of two things may have happened The stove door may have been closed prematurely and the stove itself has not reached optimum temperature Reopen the door and or draft control to re establish a brisk fire The other problem may have been wet wood The typical symptom is sizzling wood and moisture being driven from the wood Achieving proper draft Draft is the force which moves air from the stove up through the chimney The amount of draft in your chimney depends on the length and diameter of chimney local geography nearby obstructions and other factors Adjusting the air control Item B regulates the temperature The draft can be adjusted from a low burn rate with the control fully closed to a fast burn rate with the control fully open Inadequate draft may cause back puffing into the room through the stove and chimney connector points and may cause plugging of the chimney Too much draft may cause an excessive temperature in the stove glowing red stove parts or chimney connectors or an uncontrollable burn which can lead to a chimney fire or permanent damage to the unit
15. chemin e soit chaude et fournisse un bon tirage Le feu grondant que vous voyez quand la porte est ouverte entra ne inutilement l air chaud de la pi ce vers le haut de la chemin e ce qui n est pas souhaitable Fonctionnez toujours avec la porte enti rement ferm e d s que les b ches moyennes sont enflamm es Vous pouvez maintenant ajouter de plus grands morceaux de bois et actionner le po le normalement Une fois que le po le est enti rement chaud il br lera tr s efficacement avec peu de fum e dans la chemin e Il y aura un lit de braises oranges dans la chambre de combustion et les flammes secondaires vacilleront juste au dessous de la brique r fractaire sup rieure Vous pouvez sans risque remplir le po le de bois jusqu au dessus de la porte et obtiendrez les meilleures combustions si vous gardez les temp ratures de tuyau de po le entre 250 F 121 C et 450 F 232 C Un thermom tre de surface vous aidera r gler ceci SANS THERMOMETRE DE PO LE VOUS TRAVAILLEZ L AVEUGLETTE ET N AVEZ AUCUNE ID E DE LA FA ON DONT LE PO LE FONCTIONNE UN THERMOMETRE DE PO LE OFFRE UNE INDICATION DE PERFORMANCE Vous n arrivez pas faire d marrer votre feu Utilisez un peu plus de bois d allumage et de papier Si la chemin e et le tuyau d vacuation sont de grandeur appropri e et si il y a suffisamment d air comburant alors le probl me est d au manque de petits morceaux de bois d allumage sec en quanti
16. eens N Fist 01 32 300132 RJ Pida a A a AA QE alee me E id Paba 04 32 300132 EF PIG AER to ad Ade ds e NI tran de PO ARR o E 04 32 300132 77 Piedi s d anag E date ae Noria a ment 04 12 N Code 33 301172 33 301172 33 301172 34 134711 35 101055 36 189825 37 101057 38 134714 39 331800 39 331800 39 331800 40 331900 40 331900 40 331900 41 110404 42 181632 43 188829 44 259015 45 142881 46 808001 47 101054 48 181634 49 181633 50 181625 51 142316 52 134107 ACCESSOIRES 60 EP63 61 EP90 K 90 113KT 111KT RJ EF 77 RJ EF 77 RJ EF 77 00 ED Description Pos iva a N F Qty Porte cendrier Free 01 Porte cendrier Pi psg hoe ne Bae La 4 01 Porte cendrier Nu sein Lise 01 Goupille cannel e Ps tds N A 01 Axe de fermeture Pos tye 4 Ni 4 5 44 Piz a 01 Vis M5X6 Po a N Fee 03 Axe DIAM 8 E te N FL 01 Goupille cannel e 6X24 Poiana Napaa ZETTE 01 Porte droite 22 ao ece ee eee ES ee de de cp E oaia Fine 01 Porte droite Peen ae e dey ek Joy de a dore 01 Porte droite 2 4 24 eA La das das em d mb bdd Niro us aus de bh toe 01 Porte gauche Fie ies 01 Porte gauche Percent Ge tees do dd o ees Meee 01 Port gauche
17. et d passer d au moins 2 pieds toute surface ou structure et situ e lint rieur d une distance horizontale de 10 pieds Si l int rieur de l attique votre chemin e est entour e un cran protecteur pour les chevrons est requis Air ext rieur Si possible raccordez la prise d air la base de l appareil avec une prise d air ext rieur de 4 100 mm de diam tre disponible chez votre d taillant Napol on Wolf Steel lt e Suivez les instructions de Air ext rieur de maison mobile Inversion du collet de conduit d vacuation Le collet de conduit d vacuation est orient pour une vacuation sur le dessus Retirez les deux boulons et tournez le collet 180 degr s Fixez le collet en place l aide des deux boulons crous et rondelles Installation du r cup rateur de cendre Pour viter des dommages pendant le transport le r cup rateur de cendre a t plac derri re la porte de l appareil Pivotez le r cup rateur de cendre sur la patte A et abaissez pour le placer Evacuation travers un mur Si possible l installation des conduits de raccordement ne doit pas passer travers un mur combustible S il faut absolument passer travers un mur combustible consultez votre inspecteur en b timent avant de proc der Consultez aussi le fabricant des conduits de raccordement pour toutes contraintes particuli res Consultez votre d taillant pour tout compos
18. expenses related to the reinstallation of a warranted part and such expenses are not covered by this warranty Notwithstanding any provisions contained in the President s Limited Lifetime Warranty NAPOLEON S responsibility under this warranty is defined as above and it shall not in any event extend to any incidental consequential or indirect damages This warranty defines the obligations and liability of NAPOLEON with respect to the NAPOLEON wood fireplace and any other warranties expressed or implied with respect to this product its components or accessories are excluded NAPOLEON neither assumes nor authorizes any third party to assume on its behalf any other liabilities with respect to the sale of this product NAPOLEON will not be responsible for over firing downdrafts spillage caused by environmental conditions such as rooftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting configurations insufficient makeup air or negative air pressures which may or may not be caused by mechanical systems such as exhaust fans furnaces clothes dryers etc Any damages to fireplace combustion chamber heat exchanger brass trim or other component due to water weather damage long periods of dampness condensation damaging chemicals or cleaners will not be the responsibility of NAPOLEON The bill of sale or copy will be required together with a serial number and a model number when making any warranty
19. hot enough to catch fire If necessary spray with a fire extinguisher or water from a garden hose 4 Do not operate the stove again until you are certain the chimney and its lining have not been damaged 11 ORDERING PROCEDURES Contact your dealer or the factory for questions concerning prices and policies on replacement parts Normally all parts can be ordered through your Napoleon dealer or distributor When ordering replacement parts always give the following information 1 Model amp Serial Number of fireplace 2 Installation date P 1600CP Painted 3 Part Number 4 Description of part N 1600CN Brown 5 Finish F 1600CF Green N Code Description Pis os N F Qty 1 352165 RJ Topiplato 2 1 tack Catt Nea O no Ad pote Fes 01 1 352165 EFS TOP PlAte ainia 4 Us au oa Pis acid taste je can 01 1 352165 77 Jop plate a a tr de MUR Re es NU RE re chad es 01 2 269443 Deflector Pat tas N ESS 01 3 326602 00 Flue baffle Pog Bedok Ne ge Poemas 01 4 222566 00 Secondary air plate Bin ins Ni ce Fute 01 5 259037 00 Bracket air plate Pre N R 02 6 310830 RJ Leftiside panels 2 2 nenne ra amp R 44 ada mg des mat e Fee ts 01 6 310830 EF Left side panel Pi das Regent dey ae Bi aka ee 01 6 310830 77 Left side panel Ne ea rater 01 7 305016 EF Liner left side
20. the chimney passes through 3 Hold a plumb bob from the underside of the roof to determine where the opening in the roof should be Cut and frame the roof opening to maintain proper 2 clearances Adding chimney sections Add chimney sections according to manufacturer s installation instructions to the required height The chimney must extend atleast 3 feet above its point of contact with the roof and atleast 2 feet higher than any wall roof or building within 10 feet If your chimney system is enclosed within the attic area a rafter radiation shield is required Outside air If possible connect the air intake at the bottom to the outside with a 4 inch 100mm diameter fresh air kit available at your Napoleon Wolf Steel Ltd dealer Follow detailed instructions under Mobile Home Outside Air Flue collar reversal The flue collar is oriented in the Top Exit position Remove the two mounting bolts and turn the collar 180 degrees Secure the collar using the same bolts nuts and washers Ash fender installation To avoid damage during transport the ash fender has been stored behind the main door Pivot the ash fender onto tab A and lower into place Wall pass through If possible design the installation so that the connector does not pass through a combustible wall If during your installation you must pass through a combustible wall check with your building inspector before you KP
21. thereby allowing ash to be in contact with the underside of the grate If this condition is allowed the grate will wear out prematurely Hot ashes may be kept in a metal container with a tight fitting lid Keep the closed container on a noncombustible floor or ground well away from all combustible materials The ashes should be retained in the closed container until all cinders have thoroughly cooled Cold wood ashes can be used on the garden or in the compost DO S 1 Build a hot fire 2 Use only dry wood 3 Several pieces of medium sized wood are better than a few big pieces 4 Clean chimney regularly 5 Refuel frequently using medium sized wood 6 Fine Tune the air settings for optimum performance DON TS 1 Take ash out immediately Let it accumulate to a depth of at least one inch A good ash layer provides for a longer lasting and better burning fire 2 Burn wet wood 3 Close the door too soon or damper down too quickly 4 Burn one large log rather than two or three smaller more reasonably sized logs 5 Burn at continually low setting if glass door is constantly blackened This means the firebox temperature is too low EP90 K OPTIONAL SCREEN KIT The 1600C 1 may only be operated with the doors open when spark screen EP90 K is used and installed properly This kit is not applicable for mobile homes 10 WOOD PILE MAINTENANCE Burn only dry clean unpainted wood that has been seas
22. unit is extremely airtight lt has an exclusive direct outside air supply optional kit a safety feature designed to prevent spillage and to keep your house free of carbon monoxide in case of a downdrafting chimney or an internal negative pressure When lit for the first time The stove will emit a slight odour for a few hours This is a normal temporary condition caused by the burn in of internal paints and lubricants used in the manufacturing process and will not occur again Simply open a window to sufficiently ventilate the room during the first few hours of operation To start a brisk fire is required Place loosely crumpled paper on the grate and cover with dry kindling Open the air control fully by moving it to the right Light the paper and leave the door slightly ajar one inch until all kindling is burning To maintain a brisk fire a hot coal bed must be established and maintained Slowly add larger wood 2x4 size pieces Lay the pieces lengthwise from side to side in the hot coal bed with a shallow trench between so that the primary air can flow directly into this trench and ignite the fuel above When the fire seems to be at its peak medium sized logs may be added Once these logs have caught fire carefully close the door Closing the door too quickly after refuelling will reduce the firebox temperature and result in an unsatisfactory burn Remember it is
23. ATION AVEC Soufflerie optionnelle EP63 LE KIT SOUFFLERIE EP63 M thodes de d cendrage Ajout de sections de chemin e Pare tincelles optionnel EP90K Air ext rieur Inversion du collet de conduit d vacuation ENTRETIEN DU TAS DE BOIS ENTRETIEN DU PO LE Installation du r cup rateur de cendre Formation et enl vement de cr osote vacuation travers un mur Feu de chemin e ou feu hors contr le Installation de l cran de dessous REMPLACEMENTS Principe de fonctionnement Soin de la vitre INSTALLATION Installation dans une alc ve Installation du po le Pp 5 ois Pp 5 pp pp 9 INSTALLATION MAISON MOBILE p L vacuation SP CIFICATIONS MODELE 1600C 1 LARGEUR X PROFONDEUR 681 X 615 mm 26 8 X 24 2 HAUTEUR 712 mm 28 0 HAUTEUR D PART ARRI RE A 698 mm 27 5 FOYER P L H 304 X 520 X 265mm 11 9 X 20 4 X 10 4 CONTENANCE LITER 41 3L 1 46 f SURFACE CHAUFF E 56 112 m 600 1200 ft PUISSANCE MAXI 14 kw DUR E 7 hr POIDS 150 KG 330 LB CES DONN ES VARIENT CONSID RABLEMENT
24. INSTALLER THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER CERTIFIED UNDER U S ENVIRONMENTAL PROTECTION AGENCY E P A JULY 1990 AND THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY D E Q PARTICULATE EMISSION STANDARDS BY E E M C THESE STOVES HAVE BEEN TESTED AND LISTED BY WARNOCK HERSEY LTD TO STANDARDS UL 1482 ULC S627 MODEL 1600C 1 HAS BEEN TESTED AND LISTED FOR INSTALLATION IN MOBILE HOMES NAPOLEON QUALITY STOVES INSTALLATION AND OPERATION INSTRUCTIONS FOR LISTED SOLID FUEL BURNING SPACE HEATER MODEL 1600C 1 WARNING Please read this entire manual before you install and use your new room heater Failure to follow instructions may result in property damage bodily injury or even death If this stove is not properly installed a house fire may result FOR YOUR SAFETY Follow the installation directions This stove can be very hot when burning Combustible materials such as firewood wet clothing etc placed too close can catch fire Children and pets must be kept from touching the stove when it is hot The chimney must be sound and free of cracks Before installing this unit contact the local building or fire authority and follow their guidelines Operate only with door tightly closed The door must be kept closed during operation to prevent smoke embers from entering the room Burn wood directly on cast grate supplied Do not elevate the fire An opening of at least 14 square i
25. IOVE oi A eR we Ru aia Peis as ed N Fins 01 Blower Kits amp 2 sre se ee Aer durent eS Paire Ni sas F Screen kit S dis Lu es Ed gestes LR m0 4 Poda Nick baa F Adapter kit s 2 20 42 0 eae fe Sek Palta Nana F Outside air kitas 4 244 ic ee de au wa Pra si ba No ned F 13 14 INSTALLATEUR CETTE NOTICE DOIT TRE REMISE AU PROPRI TAIRE DU PO LE ET CONSERV E PAR LUI HOMOLOGU SELON LES NORMES DE L AGENCE DE PROTECTION DE L ENVIRONNEMENT AM RICAINE E P A JUILLET 1990 ET LE D PARTEMENT D OREGON DE LA QUALIT DE L ENVIRONNEMENT D E Q LES NORMES D MISSION DE PARTICULES DE E E M C CE PO LE A T TEST ET HOMOLOGU PAR WARNOCK HERSEY LT E SELON LES NORMES UL 1482 ULC S627 LE MOD LE 1600C 1 A T TEST ET HOMOLOGUE POUR INSTALLATION LES MAISONS MOBILES c NAPOLEON QUALITY STOVES INSTRUCTIONS D INSTALLATION ET D OP RATION POUR LES APPAREILS DE CHAUFFAGE LOCALIS A COMBUSTIBLE SOLIDE MOD LE 1600C 1 ATTENTION Veuillez lire le manuel d instructions en entier avant d installer et d utiliser votre appareil de chauffage Si ces instructions ne sont pas suivies la lettre des dommages mat riels des blessures corporelles ou des pertes de vie pourraient s ensuivre Si cet appareil n est pas install ad quatement un incendie pourrait en r sulter POUR VOTRE S CURIT Observez les instructions d installation Ce po l
26. SELON LES CONDITIONS INDIVIDUELLES BTU H R ALISTES ESTIM S PAR WOLF STEEL LT E AVEC B CHES DE BOIS DUR ET RAVITAILLEMENT NORMAL INTRODUCTION Informations g n rales Le po le bois 1600C 1 a t sp cifiquement con u pendant plusieurs mois de recherches pour satisfaire les exigences de l E P A am ricaine concernant les missions standard de particules pour 1990 il a t consid rablement test par les laboratoires canadiens et am ricains Ce syst me est le plus efficace le plus simple et sans probl mes connus il fonctionne comme suit Le 1600C 1 est un appareil de chauffage au bois a fonctionnement continu ayant une chambre de combustion ferm e avec parois en fonte o tout le combustible est br l sur la grille fournie C est un appareil fonctionnant en d part dessus et arri re et pouvant tre install pr s d un mur ll dispose d une commande d air permettant de bien contr ler son allure de fonctionnement et est quip d un cendrier de grande contenance NOTE Avant de mettre votre appareil en fonctionnement veillez retirer les articles pouvant se trouver l int rieur buse de raccordement outil d ouverture de porte tisonnier r cup rateur de cendre et mat riel d installation After removing the unit from the pallet use the securing screws to install the heat shield to the base of the unit Principe de fonctionnement Le po le bois 1600C 1 est concu pour fonctionner a
27. a chaleur Plus le bois est humide moins il y aura de chaleur et plus il y aura de cr osote Le bois dur et le bois tendre br lent galement bien dans ce po le mais le bois dur est plus dense p sera plus lourd par corde et br lera plus lentement et plus longtemps Le bois de chauffage devrait tre fendu empil de sorte que Pair puisse s tendre toutes les parties de celui ci et couvert en d but de printemps pour tre pr t br ler l automne Le bois de chauffage sec a des fissures a l extr mit de ces veines Coupez le bois de sorte qu il soit dispos horizontalement d avant en arri re facilitant le chargement et vitant que le bois ne roule sur la vitre ENTRETIEN DU PO LE Afin de pr venir les accumulations de suie et de cr osote v rifiez vos chemin e et tuyau fum e toutes les semaines jusqu ce qu une fr quence de nettoyage s curitaire soit tablie Si les accumulations sont excessives d branchez le po le et nettoyez le ainsi que la chemin e A l aide d un aspirateur nettoyez le d flecteur sup rieur du po le Vous pourriez faire appel aux services d un ramoneur professionnel pour nettoyer le po le et la chemin e ils doivent tre nettoy s au moins une fois l an ou aussi souvent que n cessaire ENFUMAGE Un po le Napol on install convenablement ne devrait pas fumer Si le v tre fume v rifiez les points suivants Est ce que la chemin e a pu se r chauffer suffisammen
28. acid When refueling open the door slowly to prevent smoke spillage Use a pair of long gloves barbecue gloves when feeding the fire Because these stoves burn at the front they are clean and efficient but they are also very hot and gloves are useful Keep a small steel shovel nearby to use as a poker and to remove ashes Do not store the wood within 3 feet 1m of the stove EP63 OPTIONAL BLOWER KIT O Remove the 4 screws from the rear plate of the stove Replace the screws removed with the 4 spacers supplied Install the rear heat shield using the 4 screws removed and secure to the 4 spacers The flue collar shield is only needed if the flue collar is in the top exit position If the flue collar is in the rear exit position the flue collar shield can be discarded Install the flue collar shield to the rear heat shield using 2 of the screws supplied O Install the blower and housing using 4 of the screws supplied Loosen the 2 screws securing the thermodisc bracket and slide the bracket forward until the thermodisc is touching the heat shield Secure in place by tightening the screws Ash removal procedures CAUTION Risk of excessive temperatures Keep the ash door closed during firing of the heater It is essential to keep the grate free of a heavy build up of ashes When burning solid fuel always empty the ash pan at least once a day or whenever it is full of ashes Never allow the ashpan to overfill
29. aissez la porte l g rement entreb ill e un pouce jusqu ce que tout le bois d allumage soit enflamm Pour maintenir un feu vif un lit de braises chaud doit tre tabli et maintenu Ajoutez lentement du bois de plus grande taille morceaux de taille 2 x 4 R partir les morceaux de bois en longueur d un c t l autre du lit de braises chaud s par par un foss peu profond de sorte que lair primaire puisse s couler directement dans ce foss et mettre feu le combustible au dessus Quand le feu semble tre son point haut des b ches de tailles moyennes peuvent tre ajout es Une fois que ces b ches sont enflamm es fermez soigneusement la porte la fermeture de la porte trop rapide apr s r approvisionnement en combustible r duira la temp rature et engendrera une combustion insuffisante Rappelez vous qu il est plus efficace de br ler des b ches de dimension moyenne feu vif et de recharger en combustible fr quemment que de charger la chemin e avec des grandes b ches qui a comme cons quence un feu couvant inefficace et une vitre sale D s que la porte sera ferm e vous observerez un changement de la forme des flammes Les flammes deviendront plus petites et plus paresseuses parce qu il y moins d oxyg ne qui entre dans la chambre de combustion Les flammes cependant sont plus efficaces Les flammes resteront paresseuses mais plus grandes d s que le po le sera compl tement chaud et que la
30. an de buse utilisez les 2 vis fournies Installez la soufflerie et le boitier l aide des 4 vis fournies Desserrez les 2 vis servant fixer le support du thermodisque et glissez le thermodisque vers l avant jusqu ce qu il touche l cran arri re Fixez en place en resserrant les vis M thodes de d cendrage ATTENTION Danger de temp ratures lev es Gardez la chute cendres bien ferm e lorsque le po le est en fonction Il est essentiel de maintenir la grille exempte d une accumulation importante de cendres En br lant du combustible solide videz toujours le cendrier au moins une fois par jour ou toutes les fois qu il est plein des cendres Ne laissez jamais le cendrier se remplir de facon excessive et permettre aux cendres d tre en contact avec le dessous de la grille Si cela arrivait la grille se d t riorerait pr matur ment Des cendres chaudes peuvent tre maintenues dans un r cipient en m tal avec un couvercle convenablement serr Gardez le r cipient ferm sur un plancher non combustible ou la terre bien l cart de tous mat riaux combustibles Les cendres devraient tre maintenues dans le r cipient ferm jusqu ce que toute la cendre se soit compl tement refroidie Des cendres de bois froides peuvent tre utilis es sur le jardin ou dans le compost A FAIRE 1 Construisez un feu chaud 2 Br lez du bois sec seulement 3 Plusieurs morceaux de dimension moyenne sont
31. ant autoris NAPOLEON et sous r serve des conditions et limitations suivantes Cette garantie d usine n est pas transmissible et ne peut tre tendue par aucun de nos repr sentants qu elle qu en soit la raison Le po le au bois doit tre install par un installateur ou entrepreneur qualifi L installation doit tre faite conform ment aux instructions d installation inclues avec le produit et tous les codes d incendie et de construction locaux et nationaux Cette garantie limit e ne couvre pas les dommages caus s par un usage impropre un manque d entretien un accident des alt rations des abus ou de la n gligence L installation de pi ces d autres fabricants annulera cette garantie Cette garantie limit e ne couvre pas non plus les raflures les bossellements la corrosion ou d coloration caus s par une chaleur excessive des produits d entretien chimiques et abrasifs ou l caillage des pi ces en mail de porcelaine ou tout composant de ventilation utilis dans l installation du po le Au cours de la premi re ann e seulement cette garantie s tend la r paration ou le remplacement des pi ces garanties dont les mat riaux ou la fabrication sont d fectueux sous condition que le produit ait t utilis conform ment aux instructions de fonctionnement et sous des conditions normales Apr s la premi re ann e concernant cette Garantie Vie Limit e du Pr sident NAPOLEON peut sa discr tion se d barrasser en
32. ant de raccordement travers un mur dont vous auriez besoin N utilisez que les pi ces qui ont t test es et certifi es pour des installations travers un mur Voici la fa on id ale de passer un conduit de raccordement travers un mur combustible jusqu la chemin e de ma onnerie Installation de l cran de dessous L cran de dessous plac dans le po le doit tre install sous l appareil avec 2 vis pr vues Reportez vous la page 8 afin de respect le sens de montage de l cran de dessous INSTALLATION DANS UNE MAISON MOBILE LE MODELE 1600C 1 EST HOMOLOGU POUR INSTALLATION DANS LES MAISONS MOBILES AU CANADA ET AUX TATS UNIS Le po le doit tre fix au plancher de la maison mobile Avertissement N installez pas ce po le dans une chambre coucher N installez pas ce po le de facon compromettre Pint grit structurale du plancher des murs du plafond ou du toit de la maison mobile L vacuation Raccordez le po le la chemin e en utilisant un ds conduit de raccordement SCLIN ETOH double aroi certifi POUR MAISON MOBILE Utilisez r syst me de gt z f a 3 chemin e homologu selon __ CRAN DE PROTECTION la norme ULC S629 au Canada ou l quivalent aux tats Unis Ces quipements doivent tre install s conform ment aux instructions de leurs ZN fabricants N utilisez que B les composants sp cifi s A N Les s
33. as se prolonger devant la fa ade de l appareil lorsque install dans une alc ve Installation du po le Si le po le est install sur un plancher combustible il doit tre plac sur un protecteur de plancher incombustible approuv qui doit d passer les c t s et l arri re du po le de 203 mm et se prolonger de 457 mm sur le devant 1203 mm O 203 mm 457 mm Raccord simple paroi Flue configuration Type 1 Horizontal Vertical A 406 mm 406 mm DU PO LE B 254 mm 406 mm C 280 mm 280 mm D 635 mm 635 mm DU CONDUIT E q 457 mm F de 457 mm Une distance minimum de 457 mm sera maintenue entre le mur combustible et le raccord de chemin e Afin d obtenir ces mesures de d gagement il faut utiliser des raccords double parois homologu s pour une distance de 305 mm ou moins par rapport aux mat riaux combustibles Flue configuration Type 2 Horizontal Vertical A 406 mm 406 mm DU PO LE B 254 mm 254 mm C 280 mm 280 mm D 635 mm 635 mm pu E 406 mm CONDUIT F 305 mm Raccordement de la chemin e Un conduit de raccordement paroi simple de 6 de diam tre utilis pour raccorder le po le la chemin e doit tre install avec l extr mit gaufr e par
34. cedures EP90 K OPTIONAL SCREEN KIT WOOD PILE MAINTENANCE STOVE MAINTENANCE Creosote formation and removal Runaway or chimney fire ORDERING PROCEDURES SPECIFICATIONS WIDTH X DEPTH HEIGHT REAR FLUE HEIGHT A CHAMBER D W H CAPACITY LITER APP AREA HEATED HEAT OUTPUT HIGH BURN DURATION LOW FIRE WEIGHT MODEL 1600C 1 681 X 615 mm 26 8 X 24 2 712 mm 28 0 698 mm 27 5 304 X 520 X 265 mm 11 9 X 20 4 X 10 4 41 3L 1 46 f 56 112 m 600 1200 ft 50 000 Btu 7 hr 150 KG 330 LB FIGURES WILL VARY CONSIDERABLY WITH INDIVIDUAL CONDITIONS WOLF STEEL LTD ESTIMATED REALISTIC BTU H WITH HARDWOOD LOGS AND REGULAR REFUELING INTRODUCTION General information The 1600C 1 was specifically designed over many months of research to meet the 1990 U S A EPA particulate emission standards and has been extensively tested in Canadian laboratories This system is the most efficient simple and trouble free we know and works as follows The 1600C 1 is designated as a continuous wood burning heating appliance having a combusti
35. cian before packaging to ensure that you the customer receives the quality product that you expect from NAPOLEON NAPOLEON WOOD FIREPLACE PRESIDENT S LIFETIME LIMITED WARRANTY The following materials and workmanship in yournew NAPOLEON wood fireplace are warranted against defects for as long as you own the fireplace This covers combustion chamber heat exchanger ceramic glass thermal breakage only porcelainized enamelled components and cast iron castings Electrical 110V components and wearable parts such as blowers thermal switch switches wiring firebrick grate baffle gasketing and high temperature paint are covered and NAPOLEON will provide replacement parts free of charge during the first year of the limited warranty Labour related to warranty repair is covered free of charge during the first year Repair work however requires the prior approval of an authorized company official Labour costs to the account of NAPOLEON are based on a predetermined rate schedule and any repair work must be done through an authorized NAPOLEON dealer CONDITIONS AND LIMITATIONS NAPOLEON warrants its products against manufacturing defects to the original purchaser only i e the individual or legal entity registered customer whose name appears on the warranty registration card filed with NAPOLEON provided that the purchase was made through an authorized NAPOLEON dealer and is subject to the following condi
36. claims from your authorized dealer The warranty registration card must be returned within fourteen days to register the warranty NAPOLEON reserves the right to have its representative inspect any product or part thereof prior to honouring any warranty claim ALL SPECIFICATIONS AND DESIGNS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE DUE TO ON GOING PRODUCT IMPROVEMENTS NAPOLEON IS A REGISTERED TRADEMARK OF WOLF STEEL LTD PATENTS U S 5 303 693 801 CAN 2 073 411 2 082 915 WOLF STEEL LTD PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE TABLE of CONTENTS INTRODUCTION General information Principal of operation Care of glass INSTALLATION Alcove installation Stove installation INSTALLATION WHEN INSTALLED WI BLOWER KIT EP63 Adding chimney sections Outside air Flue collar reversal Ash fender installation Wall pass through Heat shield installation po 2 4 DAN RR y VS NN A AAAA x X AV SZ SES K OK es 2S os S Tr a TAN p MOBILE HOME INSTALLATION Venting Outside air 113KT 1600C Adaptor Kit Intallation OPERATING INSTRUCTIONS When lit for the first time Achieving proper draft Fire extinguishers smoke detectors Fuel loading and burn cycle EP63 OPTIONAL BLOWER KIT Ash removal pro
37. da a Pica ee a dde so taa dia E 01 25 359806 77 Frontplatte oy ape A ho eh on Oe Ee Oi NE aka cs 01 26 327905 RJ ASOMO A Le echelon pata Fes 01 26 327905 EF ASHWithay aitor hit ae un asus a ees Pee ee tides dpt See 01 26 327905 77 AShitrayis hy A de NRE i soln healed aoc 01 27 158627 Handle door Prier Nes res Fes TEE 01 28 179624 Shaft air control Pos SP eas Nic oa Pes ke oe ES 01 29 331700 Ash pan housing Peete ne N Fate te 01 30 624045 00 ASh pan is L AIR ad hele Prato Nive eu RSR 01 31 262611 Heat shield Ash Pan Pass Nov 4 Poenis 01 32 300132 RJ LOG rista a da Shana ae ce Paba 04 32 300132 EF LA TE E A PO ARR o E 04 32 300132 77 Leg 4 4 dns he als fa bu e AE at Gwe gets Nia sas ment 04 12 N Code 33 301172 33 301172 33 301172 34 134711 35 101055 36 189825 37 101057 38 134714 39 331800 39 331800 39 331800 40 331900 40 331900 40 331900 41 110404 42 181632 43 188829 44 259015 45 142881 46 808001 47 101054 48 181634 49 181633 50 181625 51 142316 52 134107 ACCESSORIES 60 EP63 61 EP90 K 90 113KT 111KT RJ EF 77 RJ EF 77 RJ EF 77 00 ED Description Pog ha La N F Qty Ash Pando coi anor 24 yh bed ata dad a aa t e chee bal bee ZETTE 01 Ash pan door Pit A A SEA Aot 01 Ash pan doom a 58 aa is a Gs See a A ww 4 Noam ee 01 Pin 6X30 ash pan door la
38. e d air ext rieur est obstru e par de la glace des feuilles etc ou parce que la porte du po le est demeur e ouverte ou cause d un ventilateur puissant en op ration etc des vapeurs et des fum es dangereuses pourraient tre aspir es dans la pi ce Adaptateur pour prise d air ext rieur 113KT PATTES mi FIXATION o A AU SOL AD SUPPORT GOUJON O m E ADAPTATEUR PRISE D AIR a sy EXTERIEUR Lorsque vous installez le 1600C 1 dans une maison mobile utilisez l ensemble de prise d air ext rieur 111KT conjointement avec l adaptateur pour prise d air ext rieur 113KT Retirez les deux vis situ es en dessous de l appareil et installez les deux supports de fixation pour plancher l aide de deux vis retir es Installez l adaptateur pour prise d air ext rieur en ins rant le support goujon de sorte que les goujons passent par les trous indiqu s Maintenez le support goujon en place et alignez les trous de l adaptateur pour prise d air ext rieur avec les goujons du support Fixez l adaptateur en place l aide des 2 crous fournis Fixez l appareil au plancher l aide des deux supports de fixation et des deux vis longues fournies Mat riaux inclus Qt Description 1 2 vis 10x1 5 2 2 crous 3 1 support goujon nf 10 Bl 4
39. e outside air feature of the stove is utilized you will never experience a shortage of combustion air If you choose not to utilize outside air and experience draft or smoking problems you may need to open a door or Window WARNING Burning your unit with the ashpan door open or ajar creates a fire hazard that may result in internal damage to the stove or a house and or chimney fire CALIFORNIA PROP 65 WARNING Use of this product may produce smoke which contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm Care of glass If the glass is not kept clean permanent discolouration and or blemishes may result Normally a hot fire will clean the glass The most common reasons for dirty glass include not using sufficient fuel to get the stove thoroughly hot using green or wet wood closing the air control so far that there is insufficient air for complete combustion If it is necessary to clean the glass use a soft cloth with a nonabrasive cleaner DO NOT CLEAN GLASS WHEN HOT The glass is very strong but do not let burning fuel rest against it and always close the door gently If the glass should ever crack while the fire is burning do not open the door until the fire is out and do not operate the stove again until the glass has been replaced with a new 4 mm thick plate of ceramic glass available from your Napoleon Wolf Steel Ltd dealer DO NOT SUBSTITUTE MATERIALS To re
40. e peut devenir tr s chaud pendant la chauffe Les mat riaux combustibles tels que le bois de chauffage les v tements d tremp s etc plac s trop pr s de l appareil peuvent prendre feu Il faut emp cher les enfants et les animaux domestiques de toucher l appareil lorsqu il est chaud La chemin e doit tre en bonne condition et doit tre herm tique Avant d installer cet appareil contactez le service du b timent ou le service d incendie de votre municipalit et suivez leurs directives Ne faites fonctionner l appareil qu avec la porte herm tiquement ferm e Vous devez garder la porte ferm e durant le fonctionnement pour viter que la fum e et les braises s infiltrent dans la pi ce Br lez le bois directement sur le chenet en fonte fourni avec l appareil Ne sur levez pas le feu Au moins 14 carr s 90 cm ca d air ext rieur doit tre admis dans la pi ce Cet appareil est con u pour br ler le bois son tat naturel seulement Comparativement aux bois mous ou aux bois verts fra chement coup s les bois durs et secs produiront des taux d efficacit plus lev s et des taux d missions plus bas N allumez pas l appareil avec des produits chimiques ou des fluides tels que de l essence de l huile moteur etc Ne br lez pas de bois trait s du charbon du charbon de bois du papier couleur du carton des solvants ou des d chets qui ont tendances produire plus de pollution que le bois Ne laissez pas chauffer l appare
41. ey connector Flue configuration Type 1 Horizontal Vertical A 16 16 FROM E UNIT B 10 16 C 11 11 D 25 25 FROM PIPE E ye F 18 A 18 in Minimum clearance should be maintained from combustible wall to the chimney connector Double walled connectors listed for a minimum clearance of 12 or less from combustible materials must be used to achieve the following clearances Flue configuration Type 2 Horizontal Vertical A 16 16 FROM UNIT B 10 10 C 11 11 D 25 25 FROM PIPE E 1e F 12 Chimney connection A 6 diameter single wall stove pipe used to connect the stove to the chimney must be installed with the crimped end toward the stove This will ensure that the moisture which condenses from the burning wood will flow back into the fire chamber Each joint in the stove pipe must be secured with at least three sheet metal screws This room heater must be connected to 1 A chimney complying with the requirements for Type HT chimneys in the Standard for Chimneys Factory Built Residential Type and Building Heating Appliance UL 103 or 2 A code approved masonry chimney with a flue liner Vent the stove into a masonry chimne
42. il au point o ses composants seront chauff s au rouge GARDEZ LA TEMPERATURE SUR LE DESSUS DE L APPAREIL SOUS 700 F 371 C Toute tentative de d passer le d bit maximum de chaleur tel que mentionn dans les sp cifications du design des po les pourrait provoquer la distorsion de l acier et causer des dommages Wolf Steel Ltd 24 Napoleon Rd Barrie ON Canada L4M 4Y8 705 721 1212 Fax 705 722 6031 www napoleonfireplaces com Email ask napoleon on ca member Warnock Hersey Be ver 1PB C CHPBA Cc Ha US Hearth Patio amp Barbecue Association of Canada lal 9001 m an International Affiliate of HPBA Hearth Ratio amp Barbecue Association AFAQ N 1995 4027 ga a Document n 1178 1 02 12 2004 Les po les au bois NAPOLEON sont fabriqu s conform ment aux normes strictes du certificat d assurance de qualit mondialement reconnu ISO 9001 Les produits NAPOLEON sont con us avec des composants et des mat riaux de qualit sup rieure assembl s par des artisans qualifi s qui sont fiers de leur travail Le po le entier est soigneusement inspect par un technicien qualifi avant d tre emball pour garantir que vous le client recevez le produit de qualit que vous attendez de NAPOLEON LA GARANTIE DU PR SIDENT Les mat riaux suivants et la fabrication de votre nouveau po le au bois NAPOLEON sont garantis contre les d fauts tant que vous en tes le propri taire Ceci c
43. more efficient to burn medium sized wood briskly and refuel frequently than to load the fireplace with large logs that result in a smouldering inefficient fire and dirty glass As soon as the door is closed you will observe a change in the flame pattern The flames will get smaller and lazier because less oxygen is getting into the combustion chamber The flames however are more efficient The flames will remain lazy but become larger again as soon as the castings have been heated thoroughly and the chimney becomes heated and provides a good draft At this point the roaring fire that you see when the door is opened is wastefully drawing heated room air up the chimney certainly not desirable So always operate with the door fully closed once the medium sized logs have caught fire You can now add larger pieces of wood and operate the stove normally Once the stove is entirely hot it will burn very efficiently with little smoke from the chimney There will be a bed of orange coals in the firebox and secondary flames flickering just below the top firebrick You can safely fill the firebox with wood to the top of the door and will get best burns if you keep the stove pipe temperatures between 250 degrees Fahrenheit 121 degrees Celsius and 450 degrees Fahrenheit 232 degrees Celsius A surface thermometer will help regulate this WITHOUT A STOVE THERMOMETER YOU ARE WORKING BLINDLY AND HAVE NO IDEA OF HOW THE STOVE IS OPERATING A
44. move the door glass open the door remove the screws and brackets holding the glass in place Remove all broken glass Replace the gasket if necessary Place the new glass in position and replace the brackets and screws INSTALLATION For reduced clearances installation must comply with NFPA 2110r CAN CSA B365 For clearances when installed with blower kit EP63 refer to page 6 Alcove installation Model 1600C 1 may be installed into an alcove having a depth of not more than 4 feet and a height of at least 7 feet when using a listed double wall connector that is rated for a minimum 12 clearance to combustible material The minimum clearances are as shown Alcove installation 84 4 foot max Illustrated with 75 hearth pad Walls shall not extend from front of unit when installed in the alcove configuration Stove installation If the stove is to be installed ona combustible floor it must be 8 placed on a approved non combustible hearth pad 8 g that extends 8 200mm beyond the stove sides and back and 18 455mm to the 18 front ANN Ry Listed single wall chimney connector Flue configuration Type 1 Horizontal Vertical A 16 16 FROM a UNIT B 22 22 C 15 15 25 25 FROM P PIPE E _ 22
45. nches 90 sq cm of outside air must be admitted to the room This stove is designed to burn natural wood only Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods as compared to softwoods or too green or freshly cut hardwoods Do not start a fire with chemicals or fluids such as gasoline engine oil etc Do not burn treated wood coal charcoal coloured paper cardboard solvents or garbage which tend to produce more pollution than wood Do not let the stove become hot enough for any part to glow red KEEP THE STOVE TOP TEMPERATURE BELOW 700 F 371 C Attempts to achieve heat output rates that exceed stove design specifications can result in metal distortion and damage Wolf Steel Ltd 24 Napoleon Rd Barrie ON Canada L4M 4Y8 705 721 1212 Fax 705 722 6031 www napoleonfireplaces com Email ask napoleon on ca member sar CHPBAC CHPBA Hearth Patio amp Barbecue Association of Canada E 9001 an International Affiliate of HPBA Hearth Patio Bar ue Association AFAQ N 1995 4027 gar T a Document n 1178 1 02 12 2004 NAPOLEON wood fireplaces are manufactured under the strict Standard of the World Recognized ISO 9001 2000 Quality Assurance Certificate NAPOLEON products are designed with superior components and materials assembled by trained craftsmen who take great pride in their work The complete fireplace is thoroughly inspected by a qualified techni
46. on chamber enclosed with cast brick walls where all fuel is meant to be burnt on the grate supplied It is a top and rear vented appliance capable of being installed near a wall It has an adjustable air control for controlling the burning rate as well as a large ash pan NOTE The following items supplied with the unit must be removed from the firebox before attempting to operate the stove door handle tool ash fender and installation hardware After removing the unit from the pallet use the securing screws to install the heat shield to the base of the unit Principal of operation The 1600C 1 is designed to be operated with the door closed The heat produced is mainly transmitted through the window and the body of the unit Combustion occurs on the grate with a draft entry through the top of the combustion chamber Be sure to provide sufficient combustion air There are many other appliances in your home competing for air such as a kitchen range hood forced air heating devices or a bathroom exhaust fan Do not connect this unit to a chimney flue serving another appliance Expansion contraction noises during heating up and cooling down cycles are normal and to be expected After extended periods of non operation such as following a vacation or a warm weather season the fireplace may emit a slight odour for a few hours This is caused by dust particles in the firebox burning off Open a window to sufficiently ventilate the room If th
47. oned lt produces more heat and less soot or creosote Freshly cut wood contains about 50 moisture while after proper seasoning only about 20 of the water remains As wood is burned this water boils off consuming energy that should be used in heating The wetter the wood the less heat is given off and the more creosote is produced Both hardwood and softwood burn equally well in this stove but hardwood is denser will weigh more per cord and burn a little slower and longer Firewood should be split stacked in a manner that air can get to all parts of it and covered in early spring to be ready for burning that fall Dry firewood has cracks in the end grain Cut the wood so that it will fit horizontally sideways making for easier loading and less of a likelihood that the wood will roll onto the glass STOVE MAINTENANCE Check your chimney and chimney connector for creosote and soot buildup weekly until a safe frequency for cleaning is established If accumulation is excessive disconnect the stove and clean both the chimney and the stove You may want to call a professional chimney sweep to clean them Both have to be cleaned at least once a year or as often as necessary SMOKING A properly installed stove should not smoke If yours does check the following Has the chimney had time to get hot Is the smoke passage blocked anywhere in the stove chimney connector or chimney Is the room too airtight Try with a window partly open
48. ouverte trop longtemps cr ant des temp ratures extr mes lorsque lair est entra n pr cipitamment par la porte ouverte Solutions 1 Ne br lez pas du bois trait ou transform du charbon du charbon de bois du papier color ou du carton 2 Faites attention de ne pas surchauffer l unit en laissant la porte ouverte trop longtemps apr s le d marrage initial C est alors qu un thermom tre sur le tuyau de chemin e ou sur le dessus du po le serait d sirable Que faire si un feu hors contr le ou un feu de chemin e se d clare 1 Fermez le contr le de tirage compl tement 2 Appelez votre service d incendies 3 Examinez le tuyau fum e la chemin e le grenier et le toit de la maison pour voir si certaines composantes sont devenues assez chaudes pour prendre feu Si n cessaire arrosez avec un extincteur ou avec le boyau d arrosage du jardin 4 Ne faites pas fonctionner le po le avant que vous soyez certain que la chemin e et son conduit n ont pas t endommag s 11 REMPLACEMENTS Contactez votre d taillant ou l usine concernant les questions de prix et politiques relatives aux pi ces de remplacement Normalement toutes les pi ces peuvent tre command es par votre d taillant ou le distributeur NAPOLEON Lorsque vous commandez des pi ces de remplacement pr cisez toujours l information suivante 1 Num ro de mod le amp num ro de s rie du foyer 2 Date l installation du foye
49. ouvre la chambre de combustion l changeur de chaleur la vitre en c ramique cassure thermique seulement les pi ces plaqu es or contre le ternissement les composants en mail de porcelaine et les moulages en fonte Les composants lectriques 110 V et les pi ces portables telles que les ventilateurs l interrupteur thermique les interrupteurs l installation lectrique les briques r fractaires les grilles les chicanes les joints d tanch it et la peinture r sistante aux hautes temp ratures sont couverts et NAPOLEON fournira gratuitement les pi ces de rechange durant la premi re ann e de la garantie limit e Les co ts de main d uvre relatifs aux r parations garanties sont couverts gratuitement durant la premi re ann e Cependant les travaux de r parations n cessitent l approbation pr alable d un repr sentant autoris de la compagnie Les co ts de main d uvre la charge de NAPOLEON sont bas s sur un programme de tarifs pr d termin et tout travail de r paration doit tre accompli par l entremise d un repr sentant autoris NAPOLEON CONDITIONS ET LIMITATIONS NAPOLEON garantit ses produits contre les d fauts de fabrication l acheteur d origine seulement l individu ou la personne morales client inscrit dont le nom appara t sur la carte d enregistrement de garantie d pos e aupr s de NAPOLEON condition que lachat ait t fait par l entremise d un repr sent
50. pr f rables quelques gros morceaux 4 Nettoyez la chemin e r guli rement 5 Rechargez fr quemment en utilisant des morceaux de dimension moyenne 6 R gler pr cis ment les entr es d air pour obtenir des performances optimales ANE PAS FAIRE 1 Retirer les cendres imm diatement Laissez la accumuler sur une paisseur d au moins un pouce Une bonne couche de cendre favorise une attis e qui br le mieux et qui dure plus longtemps 2 Br ler du bois humide 3 Fermer la porte pr matur ment ou fermer les entr es d air trop rapidement 4 Br ler un gros morceau de bois plut t que deux ou trois morceaux plus petits de dimension plus raisonnable 5 Br ler continuellement avec les contr les trop ferm s Si la vitre de la porte est constamment noircie cela veut dire que la temp rature de la bo te feu est trop basse Pare tincelles optionnel EP90K Lorsque vous utilisez le pare tincelles EP90 K le po le 1600C 1 doit fonctionner avec les portes ouvertes Ce pare tincelles ne peut tre utilis dans des maisons mobiles 10 ENTRETIEN DU TAS DE BOIS Br lez seulement du bois non peint propre et bien sec Il produit plus de chaleur et moins de suie ou de cr osote Fra chement coup le bois contient 50 d humidit tandis qu apr s un s chage appropri seulement 20 de l eau reste Quand le bois br le l eau bout en consommant une partie de l nergie qui aurait d produire de l
51. r P 1600CP Peint noir 3 Num ro de pi ce he 4 Description de la pi ce N 1600CN Marron majolique 5 Type de finition F 1600CF Vert majolique N Code Description PE et tae N F Qt 1 352165 RJ DOSSUS ti 4 eat et oud e E di DNS Esad 01 1 352165 EF Dessus ataca as o Pis acid tete dec 01 1 352165 77 DOSSUS ils dun AURAS A rt d ee NU RE re chad es 01 2 269443 D flecteur Pat tas N ESS 01 3 326602 00 Chicane a sara ae WA ate dee dits Pog Bedok Ne ge Poemas 01 4 222566 00 Chicane ss a a es ae ee Bi es Nate Ela ses 01 5 259037 00 Patte de fixation Pr N ESS 02 6 310830 RJ C t gauche same errata raras a aa Fu 01 6 310830 EF C t gauche Pre ete Pie dee E E le tes 01 6 310830 77 C t gauche Nec ren nt 01 7 305016 EF Brique gauche Pes 22 pk Nix at Fe asad 01 8 252674 Couvercle de grille Pee it Nas ue Fakes 01 9 309233 EF GHG ss es tec ts cette Mid Ae A end Pine N ESS 01 10 322718 EF Suppl ment support Poa cias Nilo Fee ae 01 11 330018 EF Plaque motif Bi layt Nate Ela 01 12 105275 Brique d isolation c ramique Ps va N Fi 01 13 306285 EF Derri re sic bona ad pr Pog Be dks N ge Poemas 01 14 331001 EF Adaptateur Pi es Nate Ela ses 01 15 303826 EF BUS A ds do A a Pire N
52. s que les ventilateurs d vacuation les fournaises les s choirs linge etc Tous dommages au po le la chambre de combustion l changeur de chaleur la garniture de cuivre ou autre composant dus l eau les dommages caus s par le temps de longues p riodes d humidit de condensation des produits chimiques ou produits d entretien nuisibles ne seront pas de la responsabilit de NAPOLEON La facture ou sa copie sera requise ainsi qu un num ro de s rie et un num ro de mod le lors d une r clamation aupr s de votre repr sentant autoris La carte d enregistrement doit tre retourn e dans les quatorze jours pour enregistrer la garantie NAPOLEON se r serve le droit de demander son repr sentant d inspecter tout produit ou pi ce avant d honorer toute r clamation Toutes les sp cifications et les designs peuvent tre modifi s sans pr avis ou aux am liorations constantes du produit NAPOLEON est une marque de commerce d pos e DE WOLF STEEL LT E Brevets U S 5 303 693 801 CAN 2 073 411 2 082 91 5 WOLF STEEL LT E S V P CONSERVEZ CE MANUEL COMME R F RENCE TABLE des MATIERES INTRODUCTION Air ext rieur fixation au plancher Informations g n rales Adaptateur pour prise d air ext rieur 113KT INSTRUCTIONS D OP RATION Lors du premier allumage Cr er un tirage appropri Extincteurs et d tecteurs de fum e Chargement du combustible et cycle de combustion INSTALL
53. t Est ce que le passage de fum e est bloqu en quelqu endroit dans le po le le tuyau fum e ou la chemin e Est ce que la pi ce est trop herm tique Essayez avec une fen tre partiellement ouverte Est ce que le flot de fum e est restreint par un tuyau vertical trop long ou par un trop grand nombre de coudes S agit il d un tirage faible caus par une chemin e non herm tique une chemin e ext rieure froide ou une chemin e trop courte ou trop pr s des arbres ou d un toit plus lev Formation et enl vement de cr osote Lorsque le bois br le lentement il produit du goudron et autres Vapeurs organiques qui se combinent la vapeur d eau vacu e pour former la cr osote Ces vapeurs se condensent dans le conduit relativement froid de la chemin e d un po le br lant lentement et lorsqu elle prend feu la cr osote produit un feu extr mement chaud Par cons quent le tuyau fum e et la chemin e devraient tre inspect s mensuellement pendant la saison de chauffage afin de d terminer si une accumulation s est produit Si la cr osote s est accumul e elle doit tre enlev e pour r duire le risque de feu de chemin e Feu de chemin e ou feu hors contr le Des feux hors contr le peuvent tre caus s par les deux facteurs suivants 1 L utilisation d un combustible inappropri ou des morceaux trop petits qui normalement auraient t utilis s comme feu d allumage 2 Une porte laiss e entr
54. t s suffisantes Une grandeur ad quate pour le bois d allumage serait de la taille de votre pouce Votre po le n met pas assez de chaleur L une de deux choses a pu arriver La porte du po le a t ferm e pr matur ment et le po le n a pas atteint la temp rature optimale Ouvrez la porte et ou le contr le de tirage nouveau afin de reconstruire un feu p tillant Du bois mouill pourrait tre la deuxi me cause Un bois gr sillant d o s chappe l humidit en est le sympt me typique Cr er un tirage appropri Le tirage est la force qui entra ne l air du po le par la chemin e Le niveau de tirage dans votre chemin e d pend de la longueur et du diam tre de la chemin e de la g ographie locale des obstructions voisines et d autres facteurs En ajustant le clapet d air B on r gle la temp rature Le tirage peut tre ajust e d une allure de chauffe minimale avec la commande enti rement ferm e une allure de chauffe rapide avec la commande enti rement ouverte Un tirage insatisfaisant peut causer un retour de fum e dans la salle par les points de connection du po le et de la chemin e et peut causer le blocage de la chemin e Trop de tirage peut causer une temp rature excessive dans le po le faire rougir les pi ces du po le les connections de chemin e ou une allure de chauffe incontr lable qui peut mener un feu de chemin e ou des dommages permanents Extincteurs e
55. t d tecteurs de fum e Toutes les maisons poss dant un po le bois devraient conserver au moins un extincteur d incendie dans un emplacement central connu de tous et au moins un d tecteur de fum e plac dans la pi ce o le po le est situ Si l alarme retentit corrigez la cause mais ne d sactivez pas ou ne relocalisez pas le d tecteur de fum e Chargement du combustible et cycle de combustion Une fois le po le r chauff remplissez le po le avec du bois jusqu au sommet de la porte de chargement et br lez en r glant feu moyen bas pour une efficacit maximale On obtient une chaleur maximum pour un minimum de combustible quand le haut du po le atteint des temp ratures entre 500 F 260 C et 600 F 315 C Les briques r fractaires seront presque blanches et la vitre presque propre Ce sont des indicateurs du fonctionnement efficace de votre po le Lorsque vous n avez qu une ou deux b ches ou que le bois ne br le pas compl tement le po le ne produira pas assez de chaleur Il faut au moins 3 b ches pour arriver avoir un lit de braises qui nourrira le feu Des b ches plac es trop serr es les unes contre les autres br lent moins vite que celles plac es de facon plus l che Le bois br le par tapes au lieu de fournir une chaleur constante Il est donc pr f rable de planifier ces cycles selon la routine de votre famille de fa on ce que suffisamment de braises soient disponibles pour all
56. tch Bus dos Niue cd Exodo 01 Axle ash pan door latch Proa Nooo isc sha 01 Screw M 5X6 doorlatch Pita eae teed a Noise Es BaP a 03 Hinge DIAM 8 ash pandoor Pis a Ni 44 ZETTE 01 Pin 6X24 door latch Pena ais Nooo Pitra 01 Door right side coi e a ra a Boe eA Pie Both a 01 Door right side Pina da ds gousse abc din 4 01 Doof rightiSid ax 4 sti ee Eden chere ee de Nota dent A 01 Doofleft Sid s 48 ete rue oe te ne ds See Mie So ae aaa ae Bd Bo AUX de Pies Bott ps 01 Door leftside 2 4 Aui mass Atcha e Bee a a Pina s dyn as Oyen le wage de 4 01 Doorclett Side neea 24 a Gedo da de ae ee ea oe Nota ain ea 01 Hinge pin 6X30 door Pig ees ta a Nese ae Fix 2 52 ee 04 Gasket door glass Pipa Ni tea Faces deal a 2m Ceramic glass 278 X 220 Pas sue Nao Fine 02 Bracket glass retainer Pa acne tard a Nid ay herd oe CRUE 08 ROPS 2 4 02 2 uen Lu alar a Pole ch gd de ce Nes aaa Fibs a 08 Hand folies el Eo Pants aa Nao Finch 4 01 Axle doorlateh o o aobis Wo wate a Pa ae tard a Nie ake ee Pie ot acs 01 Gasket dooft 4 604 dank bd a net Lan Pro ated ob Noble F 1 64m Gasket ashpandoor Pi ns se Ninos F 1 33m Gasket ashpanhousing Pia eae tas a Ni aix a F 3 16m Gasket flue collar Pele ch kad de ce Nig 4 TETEN 1m G
57. the roof Install a rain cap at the top which will not impede the smoke exhaust The chimney must be supported at the ceiling or roof so that its weight does not rest on the stove It must be installed between ceiling joists with radiation shield and roof flashing so that the structural strength insulation and waterproof qualities of the home are not lessened Seal with silicone to maintain a vapour barrier at the chimney and outside air pipe penetrations S CHAPEAU SOLIN DE TOIT POUR MAISON MOBIL YLLLL 4 LLELLLLLELELLELA f CRAN DE PROTECTIC 7 CEILING SUPPORT j ee Te TRIM COLLAR STOVE BOLTED TO FLOOR HEARTH PAD OUTSIDE AIR CONNECTION THROUGH WALL OR FLOOR Outside air Floor Securing Connecting the stove s air intake to the outside as well as securing the unit to the floor is mandatory in mobile homes only Use a fresh air kit and the floor securing brackets Avoid cutting away floor joists wall studs electrical wires or plumbing Seal around the outside pipe with insulation to prevent drafts If room air starvation occurs because the fresh air intake is blocked with ice leaves etc or because the stove door was left open or due to a strong exhaust fan operating etc dangerous fumes and smoke from the operating stove could be drawn into the room 113KT 1600C 1 Adaptor Kit Intallation D e NS
58. ti rement de toutes obligations concernant cette garantie en remboursant l acheteur d origine le prix de gros de toute pi ce garantie mais d fectueuse Apres la premi re ann e NAPOLEON ne sera pas responsable de l installation main d uvre au autres co ts ou d penses relatives la r installation d une pi ce garantie et de telles d penses ne sont pas couvertes par cette garantie En d pit de toute disposition contenue dans cette Garantie Limit e Vie du Pr sident LA RESPONSABILIT DE NAPOLEON sous cette garantie est d finie comme ci dessus et elle ne s tendra aucun dommage accidentel cons cutif ou indirect Cette garantie d finit l obligation et la responsabilit de NAPOLEON concernant le po le NAPOLEON et toutes autres garanties exprim es ou implicites concernant ce produit ses composants ou accessoires sont exclus NAPOLEON n assume ou n autorise aucun tiers assumer en son nom toutes autres responsabilit s concernant la vente de ce produit NAPOLEON ne sera pas responsable pour une surchauffe un mauvais tirage des d versements caus s par des conditions li es l environnement telles que des toits des b timents la proximit d arbres de collines de montagnes une ventilation ou des vents inad quats une configuration d a ration excessive une constitution d air insuffisante ou des pressions atmosph riques n gatives qui sont peut tre ou peut tre pas caus es par des syst mes m caniques tel
59. tie m le sur la buse du po le Ceci permettra l humidit du bois en combustion de retourner dans la chambre de combustion Chaque joint de raccordement doit tre fix l aide de trois vis m tal Cet appareil de chauffage doit tre raccord 1 Une chemin e qui se conforme aux exigences des chemin es pr fabriqu es de type HT r sidentiel et selon le Building Heating Appliance UL 103 ou 2 Une chemin e en ma onnerie avec chemisage int gral conforme aux codes et aux exigences Raccorder le po le une chemin e de ma onnerie ou une chemin e isol e en acier inoxydable approuv e Le tuyau fum e de 6 150 mm de diam tre doit tre aussi court et aussi droit que possible Le raccordement la chemin e de ma onnerie doit se faire l aide d un manchon m tallique ou de ma onnerie ciment en place Une chemin e m tallique isol e doit tre support e au plafond ou au toit et son installation doit tre conforme aux instructions de son manufacturier A ENTRETOISES CARTEUR COUPE FEU AU BAS DE LA SOLIVE LA LONGUEUR TOTALE DU TUYAU FUM E NE DEVRAIT PAS EXC DER 40 DE LA HAUTEUR DE LA CHEMIN E AU DESSUS DU PO LE Tout tuyau fum e doit poss der une pente l g re vers le haut 1 4 au pied 6 mm au 0 3 m en direction de la chemin e et toutes les connexions doivent tre herm tiques en plus d tre solidifi es par trois vis m tal espac es galement
60. tions and limitations This factory warranty is non transferable and may not be extended whatsoever by any of our representatives The wood fireplace must be installed by an authorized service technician or contractor Installation must be done in accordance with the installation instructions included with the product and all local and national building and fire codes This limited warranty does not cover damages caused by misuse lack of maintenance accident alterations abuse or neglect and parts installed from other manufacturers will nullify this warranty This limited warranty further does not cover any scratches dents corrosion or discolouring caused by excessive heat abrasive and chemical cleaners nor chipping on porcelain enamel parts nor any venting components used in the installation of the fireplace In the first year only this warranty extends to the repair or replacement of warranted parts which are defective in material or workmanship provided that the product has been operated in accordance with the operation instructions and under normal conditions After the first year with respect to the President s Limited Lifetime Warranty NAPOLEON may at its discretion fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part s After the first year NAPOLEON will not be responsible for installation labour or any other costs or
61. ubstitutions ne sont vd pas acceptables La T chemin e et le tuyau de raccordement doivent se A TRAVERS UN MUR O UN PLANCHER prolonger d au moins 8 pi au dessus du po le et 3 pi au dessus du point le plus lev sur le toit Au sommet installez un chapeau qui ne restreindra pas le passage de la fum e La chemin e doit tre support e au plafond ou au toit de fa on ce que son poids ne repose pas sur le po le Elle doit tre install e entre les solives de plafond en utilisant un cran de protection et un solin de toit pour que la solidit de l ossature l isolation et l imperm abilit de la maison ne soient pas diminu es Scellez avec du silicone pour maintenir une barri re thermique la chemin e et aux ouvertures par lesquelles p n trent les conduits d air ext rieur 7 SUPPORT DE TOIT E COLLET DE FINITION PO LE FIX AU PLANCHER Air ext rieur fixation au plancher Le raccordement de la prise d air du po le sur lPext rieur ainsi que la fixation au plancher n est obligatoire que pour les maisons mobiles Utilisez un ensemble de prise d air ext rieur et des supports de fixation pour plancher vitez de sectionner les solives de plancher les montants muraux les c bles lectriques ou les l ments de plomberie Pour pr venir les courants d air scellez le contour du conduit d air ext rieur avec de l isolation Si la pi ce est priv e d air parce que la pris
62. umer la charge suivante Le soir chargez votre po le au moins une demi heure avant de vous coucher pour garantir un bon feu qui vous permettra de fermer le contr le du tirage pour une combustion nocturne Ne br lez que du bois bien sec Il produit plus de chaleur et moins de suie et de cr osote Ne br lez pas le bois qui a s journ dans l eau de mer le sel contenu pourra g n rer un acide qui ronge le m tal Lorsque vous rechargez le po le ouvrez la porte lentement afin d emp cher les d versements de fum e Lorsque vous alimentez le feu utilisez une paire de gants assez longs comme ceux pour le gril Ces po les sont propres et efficaces parce qu ils ont une combustion vers l avant mais ils deviennent aussi tr s chauds et les gants sont alors tr s utiles Gardez une petite pelle en acier proximit elle peut tre utilis e comme tisonnier ou pour enlever les cendres N entreposez pas le bois a moins de trois pieds un m tre du po le Soufflerie optionnelle EP63 Aa 2 La z De 24 SU THERNODI ST BRACKET O Retirez les 4 vis de la plaque signal tique de l appareil Remplacez les vis retirez par les 4 entretoises fournies O Installez l cran arri re en utilisant les 4 vis retirez et le fixer sur les 4 entretoises L cran de buse n est n cessaire quand cas de raccordement vertical Lors d un raccordement horizontal l cran de buse peut tre retir Pour installer l cr
63. vec la porte ferm e La chaleur produite est principalement transmise par la vitre et le corps de l appareil La combustion se produit sur la grille avec une entr e d air par le haut de la chambre de combustion Assurez vous qu il y a assez d air comburant qui rentre ll y a beaucoup d autres appareils chez vous qui ont besoin d air tels les hottes des cuisini res les installations de chauffage air puls les ventilateurs d extraction d air des salles de bain Do not connect this unit to a chimney flue serving another appliance Les bruits caus s par l expansion et la contraction lors des cycles de chauffage et de refroidissement sont tout fait normaux et il faut s y attendre Apr s de longues p riodes sans utiliser le po le telles qu la suite de vacances ou en automne il se peut qu une l g re odeur s en d gage pendant quelques heures Ceci est caus par des particules de poussi re br lant dans le po le Ouvrez une fen tre afin d a rer la pi ce de mani re suffisante Si vous utilisez la prise d air ext rieur de votre po le vous ne manquerez jamais d air comburant Si vous choisissez de ne pas utiliser cette prise d air ext rieur et que vous avez des probl mes de tirage ou de fum e vous devrez ouvrir une fen tre ou une porte AVERTISSEMENT Faire fonctionner votre appareil avec la chute cendres ouverte ou entrouverte constitue un risque d incendie et peut r sulter en des dommages internes au po le
64. y or an approved insulated solid fuel stainless steel chimney with as short and straight a length of six inch 150mm diameter smoke pipe as possible Connection to a masonry chimney must be by a metal or masonry thimble cemented in place An insulated stainless steel chimney must be supported atthe ceiling or roof and its installation must comply with its manufacturer s instructions HEADERS FIRESTOP SPACER UNDERSIDE OF JOIST THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40 OF THE CHIMNEY HEIGHT ABOVE THE STOVE All horizontal smoke pipe must slope slightly upwards a minimum of 1 4 per foot 6mm 0 3m and all connections must be tight and secured by three sheet metal screws equally spaced An uninsulated smoke pipe shall not pass through an attic roof space closet or similar concealed space or through a floor ceiling wall or partition or any combustible construction DO NOT USE ANY MAKESHIFT MATERIALS DURING INSTALLATION 1 Move the stove into position with the flue centered midpoint between two joists to prevent having to cut them Use a plumb bob to line up the centre 2 Cut and frame an opening in the roof to provide a 2 clearance between the outside of the chimney and any combustible material DO NOT FILL THIS SPACE WITH ANY TYPE OF MATERIAL Nail headers between the joist for extra support Firestop spacers must be placed on the bottom of each framed opening in any floor or ceiling that