1. 73332 rev3 10 9 08 09 56 Page 1 s morphy richards Cyclonic bagless upright vacuum cleaner Cli Please read and keep these instructions Getting the best from your new cleaner If your cleaner is not picking up as well as it should please check Dust canister It is important to regularly empty the canister even if it does not appear full Filters It is important that the pleated filter is shaken clean each time the dust canister is emptied this allows air through the appliance Wash the canister filters regularly in warm water and allow to air dry Blockages Check the hose tubes and tools for blockages Safety cut out If the air flow is blocked or the filters are not regularly cleaned a thermostat may operate If this happens switch off and disconnect from the mains supply Clear any blockage empty and clean the filters Allow 60 minutes for the thermostat to reset Belt Check and replace damaged or broken belt Height adjustment The height adjustment only comes into effect when the handle is released by the handle release pedal 2year If you have a problem or complaint please call our dedicated UK based helpline before returning your product to the retailer from where it was purchased UK Helpline 0844 871 0949 Replacement Parts 0844 873 0715 B Ireland Helpline 1800 409 119 VC73332 MUK Rev 3 For details of other Morphy Richards 7 products plus replacement parts
2. and WWW morphyrichards com accessories please see our website 73332 rev3 10 9 08 09 56 Page 2 2 E Aeon e Disconnect from the P t f mains supply before e Never use the appliance INSTRUCTIONS attempting to clear without the filters being The use of any electrical appliance requires the following common sense safety rules Primarily there is danger of injury or death and secondly the danger of damage to the appliance These are indicated in the text by the following two conventions WARNING Danger to the person IMPORTANT Damage to the appliance In addition we offer the following safety advice Location Do not use or keep this product outside Do not store the appliance near hot surfaces eg ovens or heating appliances E Mains lead Do not allow the mains lead to become strained or run this appliance over it If the electrical cable becomes damaged the cable assembly must be replaced Do not attempt this task yourself contact the helpline number that is found at the bottom of the page E Personal safety _ WARNING Keep loose clothing hair fingers etc away from the floor nozzle whenever the cleaner is connected to the mains WARNING Only lift the product by the handles and blockages clear the brush or replace the belt Disconnect from the mains supply before cleaning or emptying the appliance Never modify the cleaner in any way Never use in the presence o
3. carpet 5 Using a flat bladed screwdriver or a coin rotate the three cover fixings a quarter of a turn from lock to unlock 4 6 Lift the base cover from the rear fixing area first the cover will rotate forward Unhook the cover from the front edge and remove Ireland Helpline 1800 409 119 73332 rev3 10 9 08 09 56 Page 7 s a pomoni rotating 17 Tighten the three fixings using a brush amp belt M m screwdriver to turn the fixings a 7 Lift the metal belt guard out of the floor nozzle and put it safely to one side I 8 Slide the belt past the end of the motor drive shaft If the belt has broken remove all pieces and clean the drive shaft 9 Lift the rotating brush equally at both ends to slide it free of the floor nozzle TJ Holding the ends of the brush check it rotates freely or not if not it must be replaced Call our Helpline for replacement parts or belts H Re fitting rotating brush amp belt W 10 Hook the belt over the the drive shaft the belt must be slid sideways past the end of the drive shaft Note The belt guard must have been removed first see point 7 above 11 Refit the belt guard ensuring it is correctly located Press down fully 12 Pass the rotary brush through the belt ensuring the correct end is located against the belt 13 Pull the brush forward against the pull of the belt and locate the square ends of the brush into location slots in the flo
4. damage This guarantee is offered as an additional benefit and does not affect your statutory rights as a consumer This guarantee is valid in the UK and Ireland only Z For electrical products sold within the European Community At the end of the electrical products useful life it should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice in your country morphy richards The After Sales Division Morphy Richards Ltd Mexborough South Yorkshire England S64 8AJ Helplines office hours UK 0844 871 0949 Spare Parts 0844 873 0715 Republic of Ireland 1800 409 119 VC73332 MUK Rev 3 09 08 For details of other Morphy Richards UAT products plus replacement parts and WWW morphyrichards com accessories please see our website
5. that the cleaner is pulled over IMPORTANT Turning the cleaner sideways helps prevent the cleaner being pulled along by the stretch hose I Using amp cleaning the turbo nozzle Certain models only Attach the turbo nozzle amp to the hose end connector Following use your turbo nozzle may become clogged Turn over the nozzle and pull away any hairs or fibres If they are tightly wound around the brush carefully snip the fibres with scissors being careful not to damage the brush bar pull away from the brush bar and dispose I Using the Stair and Hair tool Certain models only Attach the stair tool to the hose connector for effective stair cleaning Attach the hair tool amp to the stair tool for fantastic pet and human hair pick up BJ B EMPTYING h N A OQ a 8 Empty the dust canister regularly even if it does not look full this will maintain the performance Remove the front cover by lifting the cover release lever Lift up the dust canister release and pull the canister away from the main body Take the canister to the dustbin Turn the lid quarter of a turn anti clockwise to unlock lift off the lid with pleated filter put to one side Lift out the central mesh filter from the dust canister 8 Brush clean if necessary Empty out the dust canister Re fit the central mesh filter Shake the pleated filter to remove all dust Re fi
6. ection filter The motor protection filter is located underneath the dust canister 1 Remove the dust canister 2 Lift out the filter and shake over a dustbin The filter may also be washed in water no detergents Allow the filter to air dry Ensure the filter is thoroughly dry before refitting 3 Replace the filter UK Helpline 0844 8710949 Replacement Parts 0844 873 0715 E Exhaust filter 0 The exhaust filter is located below the dust canister compartment 1 Remove the front cover 2 Remove the exhaust filter by pulling forward at the top and lifting it away 3 Take the filter out of the cage and shake vigorously over a dustbin The filter may also be washed in warm water Do not use detergents The filter must be completely dry before re fitting Allow filters to air dry naturally 4 Replace the filter and the front cover E Changing the belt If the brush bar stops rotating it is likely that the drive belt has snapped usually because the brush has been stalled A spare belt is supplied Replacement belts can also be obtained from Morphy Richards by calling the helpline number at the base of the page E Accessing the floor nozzle K 1 Disconnect the cleaner from the mains supply 2 Put the switch to the off position 3 Remove the front cover and the dust canister 4 Press the handle release pedal and place the cleaner face down in a flat position on a soft surface eg
7. f explosive liquid or vapours Never pick up inflammable or poisonous liquids such as petrol copier toner or other volatile substances Never pick up acids asbestos or asbestos dust Never touch the plug or cable with wet hands Unprofessional repairs can be dangerous for users Use only Morphy Richards spare parts and accessories The appliance must never be left running unsupervised This appliance is intended for domestic use only Misuse or use for commercial or any other purpose will render the guarantee invalid Always disconnect the appliance from the mains supply after use This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety To protect against fire electric shock and personal injury do not immerse cord plug or cleaner in water or other liquid UK Helpline 0844 8710949 Replacement Parts 0844 873 0715 p installed Never use the appliance to vacuum hot ashes broken glass sharp objects or liquids Never over extend the hose such that the cleaner is pulled over If the cleaner is knocked over switch off before attempting to upright Never pick the cleaner up by the floor nozzle when connected to the mains use the carrying handle hildre
8. iture brush knob Turbo nozzle Hose clip slot certain models only Floor nozzle with powered brush Handle release pedal amp Stair and Hair tool certain models only Upper handle Hose connector Flexible hose Dust canister release shown page 5 For details of other Morphy Richards products please see our website www morphyrichards com 73332 rev3 10 9 08 09 56 Page 4 s E OPERATING THE h N a oa APPLIANCE M Assembly A WARNING Do not plug in the cleaner until it is assembled Carefully unpack all of the components Lift the cleaner body to the upright position Remove the two screws that are already attached to the body From the rear of the cleaner align the handle with the groove and slide into the body If necessary use thumb and finger pressure to slide the handle into position Fasten the handle with the two screws H Floor nozzle height adjustment E DEEP CARPET WOOD amp LAMINATE SHORT PILE CARPET amp VINYL MEDIUM CARPET UK Helpline 0844 8710949 Replacement Parts 0844 873 0715 Before using the cleaner the floor nozzle height must be set to the correct height Choose the setting which most closely matches your floor surface Use the TOOLS setting when using the tools Note The height adjustment only comes into effect when the handle is released by the handle release pedal J Eco Switch Ce
9. n Children do not understand the dangers associated with operating electrical appliances Never allow children to use this appliance Children should be supervised to ensure that they do not play with the appliance or stumble over the power cord Electrical requirements Check that the voltage on the rating plate of your appliance corresponds with your house electricity supply which must be A C Alternating current If the socket outlets in your home are not suitable for the plug supplied with this appliance the plug should be removed and the appropriate one fitted WARNING The plug removed from the mains lead if severed must be destroyed as a plug with a bared flexible cord is hazardous if engaged into a live socket outlet Should the fuse in the 13 amp plug require changing a 13 amp BS1362 fuse must be fitted Ireland Helpline 1800 409 119 73332 rev3 10 9 08 09 56 Page 3 F m FEATURES Cord storage with quick Dust canister lid release cleat Eco Switch Pleated circular filter certain models only On Off switch Dust canister Front cover release Carrying handle Central mesh filter Removable front cover Nested extension tubes x2 Canister handle Exhaust filter grille Crevice nozzle Hose clip Carpet height adjustment Furn
10. or nozzle Ii 14 Rotate the brush by hand to ensure the belt is running in the centre of it s location on the brush euna the floor nozzle base cover 15 Hook the base cover into the front of the floor nozzle ensuring all four hooks are engaged 0 16 Rotating the cover downwards and rearwards slowly close the cover quarter of a turn to the lock position Note If the cover will not fully close or fixings will not lock lift the cover slightly and rotate the fixings until they are in the correct position for closure 18 Return the cleaner to the upright position re fit the dust canister and front cover Connect to the mains supply Switch on to test B HELPLINE If you have any difficulty with your appliance do not hesitate to call us We are more likely to be able to help than the store from where you bought it Please have the following information ready to enable our staff to deal with your query quickly e Name of the product e Model number as shown on the underside of the appliance e Serial number as shown on underside of the appliance UK Helpline 0844 871 0949 Replacement Parts 0844 873 0715 Ireland Helpline 1800 409 119 B WEBSITE You may also contact us through our website or visit the site to browse and purchase appliances spare parts and accessories from the extensive Morphy Richards range www morphyrichards com For detail
11. rtain models only The Eco Switch allows you to turn down the power when cleaning more delicate items such as curtains and upholstery saving energy and reducing costs 1 MIN ECO MAX E Using on carpets 1 Place the cleaner in it s upright position 2 Set the carpet height adjustment knob to the desired position 3 Release the mains cable by revolving the quick release cleat half a turn and extend the cable fully 4 Plug the cable into the mains socket 5 Step on the handle release pedal to release the handle to the desired position 6 Press the on off button to the on position IMPORTANT To prevent damage to carpets never leave the cleaner switched on in one place for an extended period e Never have the brushes set too low such that the cleaner is hard to push Ireland Helpline 1800 409 119 73332 rev3 10 9 08 09 56 Page 5 F I Using the attachments Follow steps 1 4 but set the carpet height adjustment knob to the TOOLS setting Remove the hose connector from the rear of the cleaner Lift the hose from the top handle hook Insert the hose clip into the hose clip slot Push the required attachment firmly onto the end of the hose If additional length is required attach one or both extension tubes Switch on IMPORTANT Always fix the hose clip to the main body slot when using the hose and tools Never over extend the hose such
12. s of other Morphy Richards products please see our website www morphyrichards com 73332 rev3 10 9 08 09 56 Page 8 fb E YOUR TWO YEAR GUARANTEE It is important to retain the retailer s receipt as proof of purchase Staple your receipt to this back cover for future reference Please quote the following information if the product develops a fault These numbers can be found on the base of the product Model no Serial no All Morphy Richards products are individually tested before leaving the factory In the unlikely event of any appliance proving to be faulty within 28 days of purchase it should be returned to the place of purchase for it to be replaced 1 If the fault develops after 28 days and within 24 months of original purchase you should contact the helpline number quoting model number and serial number on the product or write to Morphy Richards at the address shown 2 You will be asked to return the product in secure adequate packaging along with a copy of proof of 3 purchase Subject to the exclusions set out below 1 7 the faulty appliance will then be 4 repaired or replaced and dispatched usually within seven working days of receipt If for any reason this item is replaced during the 2 year guarantee period the guarantee on the new item will be calculated from original purchase date Therefore it is vital to retain your original receipt or invoice to indicate
13. t pleated filter with lid into the dust canister by lining up the two arrows and turning the lid quarter of a turn clockwise to lock 10 Re fit dust canister into cleaner and push to lock into position 11 Re fit the front cover 73332 rev3 10 9 08 09 56 Page 6 F E SAFETY CUT OUT If the cleaner overheats a motor protection thermostat will automatically switch the motor off If this happens switch the cleaner off unplug from the power supply and leave the cleaner to cool for at least 60 minutes Check the airways for blockages empty the dust canister and clean the filters before restarting E CLEANING THE FILTERS To maintain suction the pleated filter must be shaken clean each time the dust canister is emptied Failure to clean the filter will reduce suction and could damage the motor if used for a prolonged period This may invalidate the guarantee If the filters become damaged they must be replaced B Pleated filter This must be shaken clean at every emptying to maintain suction To thoroughly clean it wash it regularly To remove it from the dust canister lid turn the filter e anti clockwise Wash in warm water no detergent and allow to air dry before refitting E Mator prot
14. the date of initial purchase To qualify for the two year guarantee the appliance must have been used according to the manufacturer s instructions For example the filters must have been regularly cleaned as instructed Morphy Richards shall not be liable to replace or repair the goods under the terms of the Guarantee where E EXCLUSIONS The fault has been caused or is attributable to accidental use mis use negligent use or used contrary to the manufacturer s recommendations or where the fault has been caused by power surges or damage caused in transit The appliance has been used on a voltage supply other than that stamped on the products Repairs have been attempted by persons other than our service staff or authorised dealer The appliance has been used for hire purposes or non domestic use Morphy Richards products are intended for household use only Morphy Richards has a policy of continuous improvement in product quality and design The company therefore reserves the right to change the specification of it s models at any time 5 The appliance is second hand 6 Morphy Richards are not liable to carry out any type of servicing work under the guarantee 7 Consumables such as the filters and belt are not covered by the guarantee e This guarantee does not confer any rights other than those expressly set out above and does not cover any claims for consequential loss or