Home

Monte Carlo Fan Company 5MYR56 User's Manual

image

Contents

1. 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections in switch housing 3 Check to make sure the dip switches from the transmitter and receiver are set on the same frequency CAUTION Make sure main power is turned off 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight 3 Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off before entering switch housing 4 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 5 Allow break in period of 24 hours Most noises associated with a new fan will disap pear after this period 1 Make sure that the ridge of the canopy engages the notch in the downrod ball 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this dis tanc
2. Owner s Manual Ceiling Fan Installation Instructions Total fan weight o For 5MYR56 Series Fans READ AND SAVE THESE INSTRUCTIONS MONTE CARLO AD Quality Ceiling fans LISTED Installation SAFETY TIPS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS Installation work and electrical wiring must be done by qualified person s in accordance with applicable codes and standards ANSI NFPA 70 1999 including fire rated construction Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Before you begin installing the fan Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Make sure the installation site you choose
3. allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade To reduce the risk of fire electric shock or personal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 Ibs 16kg Do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control If this unit is to be installed over a tub or shower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Warning Before attempting to replace the fuse make sure that the power is turned off to the fan Replace only with 3 amp fuse Before servicing or cleaning unit Switch power off at Service panel and lock service disconnect
4. e from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 1f blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly result in smoother operation 1 Check wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulbs CAUTION Make sure main power is turned off before entering switch housing Warning Before attempting to replace the fuse make sure the power is turned off to the fan Replace only with 3 amp fuse MONTE CARLO Customer Service Center 740 S W Loop 820 Suite 110 Fort Worth Texas 76115 1 800 519 4092
5. ed into the house structure beams using the 3 lag screws provided Make sure that when the safety cable is fully extended the leadwires are longer than the cable and no stress is placed on the leadwires Loosen 2 screws and remove pin with keeper for downrod yoke cover and canopy to fit in yoke of fan install cotter pin into VO aa Remote Transmitter Dip swtiches lt a y i Remote Receiver Dip switches Set dip switches on the Remote Transmitter and Remote Receiver to the same settings This must be done so the units will communcate properly If you have other fans you can set to control from one transmitter by setting both receivers the same as the transmitter If you have more than one fan with remote You can set the dip switches to different positiosns to have seperate control House Fan Black E N Eac White 2 White Green X XXF gt Green down rod XRAN Green Bracket Make wire connections as per above diagram Connect the white wire from the fan to the White or Neutral wire from the power source Connect the black wire from the fan to the Black or hot wire from the power source Connect all Green Yellow wires from the fan Downrod and mounting bracket to the Ground wire from the house ME a Install downrod into yoke Tighten 2 downrod set screws and lock nuts z a a _ Raise fan with downrod assembled to the ceil ing bracket and han
6. g fan assembly Be sure to rotate the downrod ball so that the notch in the bracket engages the slot in the ball Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Lift Canopy to ceiling aligning the key hole slots with the screws on the bottom of the Mounting bracket Rotate the canopy Counter Clockwise to lock in place Tighten the screws to secure the Canopy See inset for Keyhole shape Take switch cap and place over 2 screws and twist into place Replace screw removed and tighten it and the two other screws securely Install wall control unit to outlet box using machine screws provided Place medallion on decorative side of blade and blade bracket to other side of blade and attach using the blade bracket screws and washers Remove cover by Snaping off from top or bottom Install 12V battery into wall remote Duracell MN21 Eveready A23 GP 23A all 12V Attach front cover to wall control with screws provided Check the motor for plastic shipping stabilizer tabs and remove them if they are present The screws washers and motor pads are pre installed to the blade holders Attach blade assembly to motor and t
7. ighten screws securely Attach cover of remote by placing over buttons and snaping into place Fan speed Light dim control but mer for up tons and down lights Fan on off T CD reverse button To control fan speed select from High Medium or low speed buttons To turn the fan off press the Fan on off button To dim upper lights press and hold U L botton To dim Lower lights press and hold D L button To turn off either up or down light press and quickly release either U L or D L button Press button marked ie to reverse the rotation direction of the fan ades Trouble Shooting If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly installation or wiring In some cases these installation errors may be mistaken for defects If you experience any faults please check this Trouble Shooting Chart If a problem cannot be remedied or you are experiencing difficulty in installation please call our Customer Service Center at the number printed on your parts list insert sheet Warning Before servicing or cleaning unit Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag 1 If fan does not start 2 If fan sounds noisy 3 If fan wobbles 4 If light does not work to the service panel
8. ing means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Phillips Screwdriver Before you begin installing the fan Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel h Install 4 x 25 watt candelabra base bulbs _ included TOOLS REQUIRED Wire Cutters Pliers Before installing this fan make sure the outlet box is properly installed to the house structure To reduce the risk of fire electric shock or per sonal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 Ibs 16 kg Install canopy onto downrod as shown Step Ladder Install the Mountiing Bracket to the Outlet box Use only the screws provided with the out let box Install yoke cover onto downrod as shown Thread black white wire and safety cable through downrod Align hole in downrod with hole in yoke and install cross pin Remove switch housing cap by removing 1 screw without key slots and loosening the other 2 screws and twist to remove For Canadian installation in both flush and downrod mode the safety cable must be install

Download Pdf Manuals

image

Related Search

Related Contents

PCA7750G02 User`s Manual  MaraMeter--3750317--BA--840F--840FC--840FM--DE  280MHz 無線呼出機能付き防災ラジオ仕様書  Symbol Technologies 1-PortPower-over  ISL54206AIRTZ-T  Tannoy T303C Cell Phone User Manual    Manuale utente - kodakpixpro.com  タッチパネルティーチング CON-PT/PD/PG ファーストステップガイド 第 5 版  Marshall 2061X User's Manual  