Home

Monte Carlo Fan Company 5CY60XX User's Manual

image

Contents

1. housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulbs CAUTION Make sure main power is turned off before entering switch housing MONTE CARLO Customer Service Center 740 S W Loop 820 Suite 110 Fort Worth Texas 76115 1 800 519 4092
2. Owner s Manual Ceiling Fan Installation Instructions Total fan weight lari H For 5CY60XX Series Fans READ AND SAVE THESE INSTRUCTI ONS WOVEN o Quality Ceiling fans LISTED WI Nan 10 11 12 13 15 16 Installation SAFETY TIPS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTI ONS Installation work and electrical wiring must be done by qualified person s in accordance with applicable codes and standards ANSI NFPA 70 1999 including fire rated construction Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Before you begin installing the fan Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities M
3. ake sure the installation site you choose allows the fan blades to rotate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade To reduce the risk of fire electric shock or personal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 Ibs Do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control If this unit is to be installed over a tub or shower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel buming equipment may be affected by this unit s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting
4. all engages the ridge in the mounting bracket This will allow hands free wiring Fan c Black 77 Blue White Green X XXF Green downrod C XXXXZI Green Bracket For pullchain controls follow diagram above Make sure that all exposed wiring is secured inside wire nuts Note Wires from house may vary in color and may not include ground wire After wiring is conplete gently push wires into junction box with wire nuts pointing upward Refer to point 3 of safety tips Install 3 screws and washers per blade and tighten securely Repeat for all 5 blades The blades will have a label showing this side up on each blade The screws washers and motor pads are pre installed to the blade holders Attach blade assembly to motor and tighten screws securely Connect plug from fan to switch house plug Install switch housing plate by twist Loosen 2 screws with key slots and ing plate with key hole slots into remove 1 screw without slot from place Replace screw removed and motor plate and save screw tighten the 3 screws securely AF Install the switch housing using the 4 Remove 4 screws and save to install screws previously removed switch housing Trouble Shooting If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly installation or wiring In some cases these installation errors may be mistaken for defects If you experience any faults please check
5. means cannot be locked securely fasten a prominent waming device such as a tag to the service panel Note For Outdoor Fans Only Suitable for use in wet locations when installed in a GFCI protected branch circuit Phillips Screwdriver Before you begin installing the fan Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel re ay Remove keeper from pin Remove pin replace keeper and save TOOLS REQUIRED Wire Cutters Pliers Before installing this fan make sure the outlet box is properly installed to the house structure To reduce the risk of fire electric shock or per sonal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 Ibs Loosen the 2 set screws in yoke for downrod to slip into yoke Step Ladder Use metal outlet box suitable for fan support must support 35 Ibs Before attaching fan to outlet box ensure the outlet box is securely fastened by at least two points to a structural ceiling member a loose box will cause the fan to wobble Use only the screws provided with the outlet box Thread wire through downrod with canopy and yoke cover assembled onto downrod Insert downrod into motor yoke Next insert clevis pin through
6. of 24 hours Most noises associated with a new fan will disappear after this period 1 Make sure that the ridge of the canopy engages the notch in the downrod ball 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor 4 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is positioned for measurement Repeat for each blade If all blade levels are not equal you can adjust blade levels by the following procedure To adjust a blade tip down insert a washer not supplied between the blade and blade holder at the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws farthest from the motor Reverse the position of the washer if blades mount from top of blade 6 If blade wobble is still noticeable interchanging two adjacent side by side blades can redistribute the weight and possibly result in smoother operation 1 Check wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch
7. this Trouble Shooting Chart If a problem cannot be remedied or you are experiencing difficulty in installation please call our Customer Service Center at the number printed on your parts list insert sheet Warning Before servicing or cleaning unit Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag Trouble 1 If fan does not start 2 If fan sounds noisy 3 If fan wobbles 4 1f light does not work to the service panel Suggested Remedy 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections in switch housing 3 Make sure that any shipping stabilizer has been removed from motor CAUTION Make sure main power is turned off 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the screws which attach the fan blade holder to the motor are tight 3 Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off before entering switch housing 4 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 5 Allow break in period
8. yoke and downrod Remove screws from stabilizer plate on bottom of fan motor Safety cable installation q dai E a I 3 lag lock screw Washer For Canadian installation and for USA fan and light kit combinations over 35 Ibs in both flush and downrod mode the safety cable must be installed into the house structure beams using the 3 lag screws washers and lock washers provided Make sure that when the safety cable is fully extended the leadwires are longer than the cable and no stress is placed on the lead wires Light Switch cme Fan Switch Control For control of fan and optional light from wall location follow diagram above NOTE A profes sional electrician is recommended for this type of installation Remove stabilizer plate you will not need this plate Make wire connections to power source using wire nuts provided Make sure that no filiments are outside of the wirenut After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the out let box and ungrounded conductor on the other side of the outlet box Raise the canopy up and align the two holes in the canopy with the two holes in the hanger bracket Secure with two screws provided l te te i a O Tighten both yoke set screws to fur ther secure downrod Carefully lift fan assembly onto mounting bracket Rotate fan so that the notch on the b

Download Pdf Manuals

image

Related Search

Related Contents

Texas Instruments TPA3008D2 User's Manual  取扱説明書  運搬・搬送費用特約  Le plan régional d`évaluation des Programmes Européens  Atlantis Land A02-PCI-W54M Network Card User Manual  300615FR , Appareils et accessoires multi  Lecture 5: The Internet, Continued  EA987FL-5 (牽引フック) 取扱説明書  Sensia 200D Connect user guide (multilingual for  取扱説明書・保証書 DM - 11  

Copyright © All rights reserved.
Failed to retrieve file