Home

Maytag MGDB850WL User's Manual

image

Contents

1. A Standard rear offset exhaust installation B Left or right side exhaust installation C Bottom exhaust installation Alternate installations for close clearances Venting systems come in many varieties Select the type best for your installation Two close clearance installations are shown Refer to the manufacturer s instructions A B A Over the top installation also available with one offset elbow B Periscope installation NOTE The following kits for close clearance alternate installations are available for purchase Please see the Assistance or Service section in your Use and Care Guide to order Over the Top Installation Part Number 4396028 10 Periscope Installation For use with dryer vent to wall vent mismatch Part Number 4396037 0 0 mm to 18 460 mm mismatch Part Number 4396011 18 460 mm to 29 737 mm mismatch Part Number 4396014 29 737 mm to 50 1270 mm mismatch Special provisions for mobile home installations The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home Terminate the exhaust vent outside Determine vent path Select the route that will provide the straightest and most direct path outdoors Plan the installation to use the fewest nu
2. 7 Close door to engage door strike TROUBLESHOOTING First try the solutions suggested here and possibly avoid the cost of a service call Dryer Operation Dryer will not run Has a household fuse blown or has a circuit breaker tripped There may be 2 household fuses or circuit breakers for the dryer Check that both fuses are intact and tight or that both circuit breakers have not tripped Replace the fuse or reset the circuit breaker If the problem continues call an electrician Is the correct power supply available Electric dryers require 240 volt power supply Check with a qualified electrician Was a regular fuse used Use a time delay fuse No heat Has a household fuse blown or has a circuit breaker tripped The drum may be turning but you may not have heat Electric dryers use 2 household fuses or circuit breakers Replace the fuse or reset the circuit breaker If the problem continues call an electrician 14 Dryer displaying code message PF power failure check the following Was the drying cycle interrupted by a power failure Press and hold START PAUSE to restart the dryer Try the following Check to see if a household fuse has blown or circuit breaker has tripped Electric dryers use two household fuses or breakers Replace the fuse or reset the circuit breaker Confirm the power cord is properly installed Select a Timed Dry heated cycle and
3. 3 8 approved aluminum or copper tubing is acceptable for lengths under 20 ft 6 1 m if local codes and gas supplier permit If you are using Natural gas do not use copper tubing T TEFLON is a registered trademark of Du Pont De Nemours and Company 7 Dryer gas pipe The gas pipe that comes out through the rear of your dryer has a 3 8 male pipe thread 674 159 12 38 mm A 1 2 NPT gas supply line B 3 8 NPT dryer pipe NOTE If the dryer is mounted on a pedestal the gas pipe height must be an additional 10 254 mm or 15 5 894 mm from the floor depending on the pedestal model For a garage installation the gas pipe height must be an additional 18 460 mm from the floor Make Gas Connection 1 Remove the red cap from the gas pipe 2 Using a wrench to tighten connect the gas supply to the dryer Use pipe joint compound on the threads of all non flared male fittings If flexible metal tubing is used be sure there are no kinks A Flared male fitting B Non flared male fitting A 0 NOTE For LP gas connections you must use pipe joint compound resistant to the action of LP gas Do not use TEFLON tape A combination of pipe fittings must be used to connect the dryer to the existing gas line Shown is a recommended connection Your connection may be different according to the supply line type size and location IS B
4. A 3 8 flexible gas connector 3 8 dryer pipe C 3 8 to 3 8 pipe elbow D 3 8 pipe to flare adapter fitting T TEFLON is a registered trademark of Du Pont De Nemours and Company 8 3 Open the shutoff valve in the supply line The valve is open when the handle is parallel to the gas pipe Fe A Closed valve B Open valve 4 Test all connections by brushing on an approved noncorrosive leak detection solution Bubbles will show a leak Correct any leak found VENTING Venting Requirements A WARNING Fire Hazard Use a heavy metal vent Do not use a plastic vent Do not use a metal foil vent Failure to follow these instructions can result in death or fire WARNING To reduce the risk of fire this dryer MUST BE EXHAUSTED OUTDOORS IMPORTANT Observe all governing codes and ordinances The dryer exhaust must not be connected into any gas vent chimney wall ceiling attic crawlspace or a concealed space of a building Only rigid or flexible metal vent shall be used for exhausting If using an existing vent system Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint m Replace any plastic or metal foil vent with rigid or flexible heavy metal vent Review vent system chart Modify existing vent system if necessary to achieve the best drying performance If this is a new vent system Vent material Use a heavy metal vent Do
5. Un espace suppl mentaire peut tre requis pour les moulures de porte et de plancher et pour les plinthes Un espace suppl mentaire doit tre envisag de tous les c t s de la s cheuse afin de r duire le transfert de bruit Pour installation dans un placard avec porte on doit pr voir des ouvertures minimales d entr e d air en haut et en bas de la porte Les portes a claire voie offrant des ouvertures quivalentes de passage de l air sont acceptables faut aussi prendre en compte l espace requis entre les appareils voisins lt 48 2 310 cm 3 76 3 76 24 lal 155 cm gt lt gt lt 1 gt gt 5 29 291 h 25 mm 737 mm 25 mm 743 mm 127 mm Encastrement Vue lat rale Porte de placard Placard ou avec orifices endroit exigu d entr e d air Exigences suppl mentaires concernant l installation dans une maison mobile Cette s cheuse peut tre install e dans une maison mobile Linstallation doit tre conforme la norme canadienne sur les maisons pr fabriqu es CAN CSA Z240 MH L installation dans une maison mobile exige Sp cifications lectriques m Un syst me d vacuation en m tal qui peut tre achet chez votre marchand faut prendre des dispositions sp ciales pour l apport d air ext rieur dans la s cheuse lors d une installation dans une maison mobile La surface de toute ouverture pour appo
6. que l essence loin de s cheuse Placer la s cheuse au moins 460 mm 18 po au dessus du plancher pour une installation dans un garage Le non respect de ces instructions peut causer un d c s une explosion ou un incendie Risque d incendie Utiliser un conduit d vacuation en m tal lourd La s cheuse est elle install e dans un placard Ne pas utiliser un conduit d vacuation en plastique Les portes du placard doivent comporter des ouvertures d a ration au sommet et en bas de la porte Un espace minimum de 1 25 mm est n cessaire l avant de la s cheuse et pour la plupart des installations un espacement minimum Le non respect de ces instructions peut causer de 5 127 mm est n cessaire a l arri re de la s cheuse un d c s ou un incendie Voir Instructions d installation Ne pas utiliser un conduit d vacuation en feuille de m tal Le conduit d vacuation ou le clapet d vacuation a l ext rieur est il obstru de charpie restreignant le mouvement de l air Faire fonctionner la s cheuse pendant 5 10 minutes Tenir la main sous le clapet d vacuation l ext rieur pour v rifier le mouvement de l air Si vous ne ressentez pas de l air en mouvement nettoyer le syst me d vacuation ou remplacer le conduit d vacuation par un conduit en m tal lourd ou flexible Voir Instructions d installation Des feuilles d assouplissant de tissu bloquent
7. A VAPEUR dense nanan 26 R GLAGE DE L APLOMB DE LA 27 ACHEVER L INSTALLATION ns 27 INVERSION DU SENS D OUVERTURE DE LA PORTE sasn 28 D PANNAGE nd es 29 Fonctionnement de la 29 R sultats de la s cheuse ceecceeeeeeeeeeeneeeeeeeteeeeeeeeeteeneeteneetes 30 DRYER SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean You can be killed or seriously injured if you don t immediately A DAN G E R follow instructions You can be killed or seriously injured if you don t follow A WARN N G instructions All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed A WARNING Risk of Fire Clothes dryer installation must be performed by a qualified installer Install the clothes dryer according to the manufacturer s instructions and local codes Do not install a clothes dryer with flexible plastic venting
8. Il vous faudra m Un emplacement avec un conduit d vacuation proximit Voir Exigences concernant l vacuation Un circuit s par de 30 amp res Une prise lectrique avec liaison la terre situ e moins de 2 pi 610 mm de l un des c t s de la s cheuse Voir Sp cifications lectriques Un plancher robuste capable de supporter un poids total s cheuse et charge de 200 Ib 90 7 kg Le poids combin d un appareil voisin doit galement tre pris en compte Un plancher de niveau ayant une pente maximale de 1 25 mm sous l ensemble de la s cheuse Si l inclinaison est sup rieure 1 25 mm installer l ensemble de pieds d extension de s cheuse pi ce no 279810 Si la s cheuse n est pas de niveau les v tements peuvent ne pas culbuter convenablement et les programmes automatiques de d tection peuvent ne pas fonctionner correctement Pour l installation dans un garage vous devez placer la s cheuse au moins 18 460 mm au dessus du sol En cas d utilisation d un pi destal il faudra 18 460 mm jusqu au fond de la s cheuse m Mod les vapeur uniquement Les robinets d eau froide doivent tre situ s moins de 4 pi 1 2 m de la s cheuse et la pression de l eau doit tre de 20 100 Ib po 137 9 689 6 kPa Vous pouvez utiliser l alimentation en eau droite de votre laveuse l aide du connecteur en Y fourni Ne pas faire fonctionner l
9. Placer la s cheuse son emplacement final Ne pas craser ni d former le conduit d vacuation 3 Sur les mod les gaz V rifier l absence de d formation de la canalisation de gaz souple 4 Une fois que le conduit d vacuation est raccord retirer les corni res et le carton RACCORDEMENT DES TUYAUX D ALIMENTATION MODELES A VAPEUR La s cheuse dolt tre connect e au robinet d eau froide l aide des nouveaux tuyaux d alimentation Ne pas utiliser de tuyaux usag s 1 Arr ter le robinet d eau froide et retirer le tuyau d alimentation de la laveuse 2 Retirer l ancienne rondelle de caoutchouc du tuyau d alimentation et la remplacer par la nouvelle rondelle fournie Si l espace le permet fixer l embout femelle du connecteur Y au robinet d eau froide REMARQUE Si le connecteur en Y peut tre fix directement au robinet d eau froide passer l tape 6 Si le connecteur en Y ne peut tre fix directement au robinet d eau froide il faut utiliser le tuyau d alimentation court Passer l tape 3 3 Fixer un tuyau court au robinet d eau froide Visser compl tement le raccord la main pour qu il souit scell au robinet 26 4 l aide d une pince serrer les raccords en effectuant deux tiers de tour suppl mentaires REMARQUE Ne pas serrer excessivement Le raccord risque d tre endommag Fixer le connecteur en Y l embout m le du tuyau
10. court Visser compl tement le raccord la main pour qu il soit scell au connecteur en Y Lun des extr mit s du tuyau long comporte un treillis m tallique l int rieur du raccord Fixer cette l extr tremit au connecteur en Y Fixer le tuyau d alimentation en eau froide de la laveuse la main jusqu ce qu il soit fix au connecteur en Y A Inlet to cold water Terminer le serrage des raccords deux tiers de tour suppl mentaires avec une pince REMARQUE Ne pas serrer excessivement Le raccord risque d tre endommag Fixer l autre extr mit du long tuyau la main jusqu ce qu il repose sur le connecteur de l lectrvanne situ e au bas du panneau arri re de la s cheuse Visser le raccord la main jusqu ce qu il repose sur le connecteur de l lectrovanne 10 Terminer le serrage des raccords deux tiers de tour suppl mentaires avecu un pince REMARQUE Ne pas serrer excessivement Le raccord risque d tre endommag 11 V rifier que les robinets d eau sont ouverts 12 V rifier s il y a des fuites autour du connecteur en Y du robinet et des tuyaux d alimentation R GLAGE DE L APLOMB DE LA S CHEUSE Contr ler l aplomb de la s cheuse en pla ant d abord un niveau sur la partie sup rieure de la s cheuse pr s de la console Puis en pla ant un niveau dans la zone situ e sur le c t de la s cheuse entre la partie sup rieure et la
11. es Les installations typiques consistent acheminer le conduit d vacuation l arri re de la s cheuse D autres installations sont possibles C D A E F G B H A S cheuse E Brides de serrage B Coude Conduit m tallique rigide ou souple C Mur D Clapet de d charge G Longueur de conduit n cessaire pour raccorder les coudes H Bouche de d charge 24 Installations d vacuation facultatives AVERTISSEMENT Risque d incendie Recouvrir tous les orifices d evacuation non utilis s avec une trousse du fabricant Contacter votre marchand local Le non respect de ces instructions peut causer un d c s un incendie un choc lectrique ou une blessure grave Trousse de recouvrage pour les orifices d vacuation pour les orifices d vacuation mon utilis Pi ce num ro W10186596 Tous mod les Cette s cheuse peut tre convertie pour une vacuation par le c t droit le c t gauche ou par le bas Si vous pr f rez vous pouvez contacter votre marchand local pour faire convertir la s cheuse A Installation d vacuation standard en d cal par l arri re Installation d vacuation par le c t gauche ou droit Installation d vacuation par le bas Autres installations o le d gagement est r duit existe de nombreux syst mes d vacuation C
12. hood style An exhaust hood should cap the vent to keep rodents and insects from entering the home m Exhaust hood must be at least 12 305 mm from the ground or any object that may be in the path of the exhaust such as flowers rocks or bushes snow line etc m Do not use an exhaust hood with a magnetic latch Improper venting can cause moisture and lint to collect indoors which may result in Moisture damage to woodwork furniture paint wallpaper carpets etc Housecleaning problems and health problems Plan Vent System Choose your exhaust installation type Recommended exhaust installations Typical installations vent the dryer from the rear of the dryer Other installations are possible B C I D 5 H A Dryer E Clamps B Elbow F Rigid metal or flexible metal vent C Wall G Vent length necessary to connect elbows D Exhaust hood H Exhaust outlet Optional exhaust installations AWARNING Fire Hazard Cover unused exhaust holes with a manufacturer s exhaust cover kit Contact your local dealer Failure to follow these instructions can result in death fire electrical shock or serious injury m Exhaust Cover Kit to cover unused exhaust holes Part Number W10186596 all models This dryer can be converted to exhaust out the right side left side or through the bottom If you prefer you may contact your local dealer to have the dryer converted
13. location Use the straightest path possible See Determine vent path in Plan Vent System Avoid 90 turns Use clamps to seal all joints Do not use duct tape screws or other fastening devices that extend into the interior of the vent to secure vent which can catch lint INSTALL LEVELING LEGS A WARNING Excessive Weight Hazard Use two or more people to move and install dryer Failure to do so can result in back or other injury To avoid damaging the floor use a large flat piece of cardboard from the dryer carton Place cardboard under the entire back edge of the dryer Firmly grasp the body of the dryer not the console panel Gently lay the dryer on the cardboard See illustration Examine the leveling legs Find the diamond marking Screw the legs into the leg holes by hand Use a wrench to finish turning the legs until the diamond marking is no longer visible Place a carton corner post from dryer packaging under each of the 2 dryer back corners Stand the dryer up Slide the dryer on the corner posts until it is close to its final location Leave enough room to connect the exhaust vent CONNECT VENT Using a 4 102 mm clamp connect vent to exhaust outlet in dryer If connecting to existing vent make sure the vent is clean The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood Check that the vent is secured to exhaust hood with a 4 102 mm clamp Move dryer into
14. restart the dryer If the message persists consult a qualified electrician Variable F1E1 F2E2 F3E1 F3E2 F7E1 F3E6 F3E7 service codes Call for service For all models without a display window If the WET indicator light is flashing and all other display indicator lights on the control panel are off Call for service Dryer Results Clothes are not drying satisfactorily drying times are too long or load is too hot Is the lint screen clogged with lint Lint screen should be cleaned before each load A WARNING Fire Hazard Use a heavy metal vent Do not use a plastic vent Do not use a metal foil vent Failure to follow these instructions can result in death or fire 15 the exhaust vent or outside exhaust hood clogged with lint restricting air movement Run the dryer for 5 10 minutes Hold your hand under the outside exhaust hood to check air movement If you do not feel air movement clean exhaust system of lint or replace exhaust vent with heavy metal or flexible metal vent See the Installation Instructions Are fabric softener sheets blocking the grille Use only one fabric softener sheet and use it only once Is the exhaust vent the correct length Check that the exhaust vent is not too long or has too many turns Long venting will increase drying times See the Installation Instructions Is the exhaust vent diameter the correct size Use 4 102 mm diameter
15. s direction 90 ou ou coudes persiennes 0 M tallique 64 pi 58 pi rigide 20 m 17 7 m 1 M tallique 54 pi 48 pi rigide 16 5 m 14 6 m 2 M tallique 44 pi 38 pi rigide 13 4 m 11 6 m 3 M tallique 35 pi 29 pi rigide 10 7 m 8 8 m 4 M tallique 27 pi 21 pi rigide 8 2 m 6 4 m Installation du syst me d vacuation 1 Installer le clapet d vacuation Utiliser du compos de calfeutrage pour sceller louverture murale l ext rieur autour du clapet d vacuation 2 Raccorder le conduit d vacuation au clapet Le conduit doit tre ins r l int rieur du clapet Fixer ensemble le conduit et le clapet avec une bride de serrage de 4 102 mm 3 le conduit d vacuation jusqu l emplacement de la s cheuse Utiliser l itin raire le plus rectiligne possible Voir D terminer l itin raire d acheminement du conduit dans Planification du syst me d vacuation viter les changements de direction 90 Utiliser des brides de serrage pour sceller tous les joints Ne pas utiliser de ruban adh sif pour conduit de vis ou d autres dispositifs de fixation qui se prolongent l int rieur du conduit pour fixer celui ci INSTALLATION DES PIEDS DE NIVELLEMENT AVERTISSEMENT Risque du poids excessif Utiliser deux ou plus de personnes pour d placer et installer la s cheuse Le non respect de cette instruction peut causer une blessure au dos ou d autre bless
16. smell gas instructions IMPORTANT The gas installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 or the Canadian Natural Gas and Propane Installation Code CSA B149 1 The dryer must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 or Canadian Electrical Code CSA C22 1 In the State of Massachusetts the following installation instructions apply m Installations and repairs must be performed by a qualified or licensed contractor plumber or gasfitter qualified or licensed by the State of Massachusetts If using a ball valve it shall be a T handle type m A flexible gas connector when used must not exceed feet INSTALLATION REQUIREMENTS Tools and Parts Optional Equipment Gather the required tools and parts before starting installation Read Refer to your Use and Care guide for information about the and follow the instructions provided with any tools listed here accessories available for your dryer For All Installations Location Requirements Flat blade screwdriver Caulking gun and compound Adjustable wrench that for installing new exhaust opens to 1 25 mm or vent AWARN NG hex head socket wrench snips new vent for adjusting dryer feet installations Level 1 4 nut driver Vent clamps recommended Knife Tape meas
17. vent material Is the dryer located in a room with temperature below 45 F 7 C Proper operation of dryer cycles requires temperatures above 45 F 7 AWARNING Explosion Hazard Keep flammable materials and vapors such as gasoline away from dryer Place dryer at least 18 inches 460 mm above the floor for a garage installation Failure to do so can result in death explosion or fire Is the dryer located in a closet Closet doors must have ventilation openings at the top and bottom of the door The front of the dryer requires a minimum of 1 25 mm of airspace and for most installations the rear of the dryer requires 5 127 mm See the Installation Instructions 15 16 SECURITE DE LA SECHEUSE Votre s curit et celle des autres est tres importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous y conformer Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous signale les dangers potentiels de d c s et de blessures graves a vous et a d autres Tous les messages de s curit suivront le symbole d alerte de s curit et le mot DANGER ou AVERTISSEMENT Ces mots signifient Risque possible de d c s ou de blessure grave si vous ne A DANG R suivez pas imm diatement les instructions Risque possible de d c s o
18. with a damp cloth to remove any dust 8 Read the Dryer Use section in your Use and Care Guide Electric Models Only 9 For power supply cord installation plug into a grounded outlet Gas Models Only 10 Check that gas supply is on 11 Check for leaks All Models 12 Select a Timed Dry heated cycle and start the dryer Do not select the Air Only Temperature setting If the dryer will not start check the following Controls are set in a running or On position Start button has been pushed firmly Dryer is plugged into an outlet and or electrical supply is connected Household fuse is intact and tight or circuit breaker has not tripped m Dryer door is closed This dryer automatically runs an installation diagnostic routine at the start of its first cycle NOTE You may notice an odor when the dryer is first heated This odor is common when the heating element is first used The odor will go away REVERSE DOOR SWING You can change your door swing from a right side opening to a left side opening if desired 1 Place a towel or soft cloth on top of dryer or work space to avoid damaging the surface Remove the door assembly 1 Open the dryer door 2 Remove the bottom screw from each of the 2 hinges that attach dryer door to front panel of dryer 3 Loosen the top screw from each of the 2 hinges in Step 2 A Loosen these screws B Remove these screws 4 Remove the dryer d
19. A B D A Pieds nivellement 4 B Connecteur en Y C Tuyau d alimentation court D Tuyau d alimentation avec connecteur angle droit E Rondelle en caoutchouc Retirer le sachet de pi ces du tambour de la s cheuse V rifier que toutes les pi ces sont pr sentes REMARQUE Ne pas utiliser les pieds de nivellement fournis avec la s cheuse en cas d installation sur un pi destal Pi ces n cessaires Consulter les codes locaux V rifier l alimentation lectrique et le circuit d vacuation existants Voir Sp cifications lectriques et Exigences concernant l vacuation avant d acheter les pi ces 18 Les installations pour maison mobile n cessitent un syst me d vacuation en m tal disponible chez le marchand chez qui vous avez achet votre s cheuse Pour en savoir plus veuillez consulter la section Assistance ou service de votre Guide d utilisation et d entretien quipement facultatif Consulter votre Guide d utilisation et d entretien pour en savoir plus sur les accessoires disponibles pour votre s cheuse Exigences d emplacement AVERTISSEMENT Risque d explosion Garder les mati res et les vapeurs inflammables telle que l essence loin de la s cheuse Placer la s cheuse au moins 460 mm 18 po au dessus du plancher pour une installation dans un garage Le non respect de ces instructions peut causer un d c s une explosion ou un incendie
20. DRYER INSTALLATION INSTRUCTIONS GAS U S A AND CANADA ELECTRIC CANADA ONLY INSTRUCTIONS D INSTALLATION DE LA SECHEUSE GAZ U ET CANADA ELECTRIQUE CANADA UNIQUEMENT Para una version de estas intrucciones en espa ol visite www Whirlpool com TABLE OF CONTENTS DRYER SAFETY 2 INSTALLATION 4 tiens mn 4 Optional Eq ipment 4 Location Requirements cccssccccssssceeessseesssseeesessseeeesssteeeesees 4 ELECTRIC DRYER POWER HOOKUP CANADA ONLY 6 Electrical Requirements ccccsscccesssceeesssseeeessseeeeessneeesesseeeeeees 6 GAS DRYER POWER 7 Gas Supply 7 Make Gas Connection 8 anne an en enterrer nn 8 Venting Requirement ccccccccecceeeeeeseeeceeeceaeeeeeeeseeeeeeaeeseeeeeaes 8 Plan Vent Systasis der docetvenasdetasteatecantens cite 9 Install Vent System 11 INSTALL LEVELING 11 CONNECT VEN Woe nee Pa ee 11 CONNECT INLET HOSES STEAM MODELS 11 LEVEL DRYER seccsssssavsssccucicnccsnsrsnescoar
21. OTE Most installations require a minimum 5 127 mm clearance behind the dryer for the exhaust vent with elbow See Venting Requirements Installation spacing for recessed area or closet installation The following spacing dimensions are recommended for this dryer This dryer has been tested for spacing of 0 0 mm clearance on the sides and rear Recommended spacing should be considered for the following reasons Additional spacing should be considered for ease of installation and servicing Additional clearances might be required for wall door and floor moldings Additional spacing should be considered on all sides of the dryer to reduce noise transfer For closet installation with a door minimum ventilation openings in the top and bottom of the door are required Louvered doors with equivalent ventilation openings are acceptable Companion appliance spacing should also be considered 14 356 mm 4g x _ 5 310 cm g 76 mm oir g 76 mm 4 88 155 cm ie leg 291 h 25 mm 743 mm 127 mm Recessed Side view closet Closet door area or confined area with vents Mobile home Additional installation requirements This dryer is suitable for mobile home installations The installation must conform to the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safet
22. a s cheuse a des temp ratures inf rieures a 45 F 7 C A des temp ratures inf rieures la s cheuse risque de ne plus s arr ter a la fin d un programme automatique Les temps de s chage risquent alors d augmenter La s cheuse ne doit pas tre install e ou remis e dans un endroit o elle sera expos e l eau et ou aux intemp ries V rifier les r glements locaux Certains codes limitent ou n autorisent pas l installation des s cheuses dans un garage un placard une maison mobile ou une chambre coucher Communiquer avec l inspecteur des b timents local D gagements de s paration respecter L emplacement doit tre assez grand pour permettre d ouvrir compl tement la porte de la s cheuse Dimensions de la s cheuse 221 4 za 565 mm 737 mm 291 Ja 743 mm REMARQUE La plupart des installations requi rent un espace minimum de 5 127 mm derri re la s cheuse pour le conduit d vacuation avec coude Voir Exigences concernant l vacuation Espacement pour une installation dans un encastrement ou dans un placard On recommande les dimensions d espacement suivantes pour cette s cheuse Cette s cheuse a t test e pour une installation avec d gagement de 0 0 mm sur les c t s et l arri re Lespacement recommand doit tre consid r pour les raisons suivantes Pr voir davantage d espace pour faciliter l installation et l entretien
23. ant au gaz sp cifique qui alimente l habitation L information sur le br leur se trouve sur la plaque signal tique dans le logement de la porte de la s cheuse Si cette information ne correspond pas au type de gaz disponible communiquer avec votre marchand ou composer les num ros indiqu s dans la section Assistance ou service dans le Guide d utilisation et d entretien Conversion au gaz de p trole liqu fi Un technicien qualifi doit effectuer la conversion Ne pas entreprendre de convertir l appareil pour l utilisation d un gaz diff rent de celui indiqu sur la plaque signal tique sans d abord consulter le fournisseur de gaz Canalisation d arriv e de gaz La canalisation doit comprendre un connecteur obtur filetage NPT 1 8 ou plus accessible pour le raccordement de l instrument de mesure imm diatement en amont de la connexion d alimentation en gaz de la s cheuse voir l illustration suivante Un tuyau IPS de 1 2 est recommand Pour les longueurs inf rieures 20 pi 6 1 m on peut utiliser des tuyaux approuv s de cuivre ou d aluminium de 3 8 si les codes locaux et le fournisseur de gaz le permettent Pour le gaz naturel ne pas utiliser de conduits en cuivre Pour les longueurs sup rieures 20 pi 6 1 m on peut utiliser des tuyaux plus gros et un adaptateur de grosseur diff rente Si la s cheuse a t convertie au gaz de p trole liqu fi on peut utiliser un t
24. caisse de la s cheuse v rifier l aplomb dans le sens avant arri re Si la s cheuse n est pas d aplomb la relever l aide d un bloc de bois Utiliser une cl pour ajuster les pieds vers le haut ou vers le bas et v rifier nouveau si elle est d aplomb ACHEVER L INSTALLATION 1 V rifier que toutes les pi ces sont maintenant install es S il reste une pi ce passer en revue les diff rentes tapes pour d couvrir laquelle aurait t oubli e 2 V rifier la pr sence de tous les outils Jeter ou recycler tous les mat riaux d emballage 4 V rifier l emplacement d finitif de la s cheuse S assurer que le conduit d vacuation n est pas cras ou pinc 5 V rifier que la s cheuse est d aplomb Voir R glage 6 de l aplomb de la s cheuse 7 Retirer la pellicule de bleue ou tout ruban adh sif rest sur la s cheuse 8 Essuyer soigneusement l int rieur du tambour de la s cheuse avec un chiffon humide pour liminer toute trace de poussi re 9 Lire Utilisation de la s cheuse en la Instructions d utilisation de la laveuse Mod les lectriques uniquement 10 Pour l installation avec cordon d alimentation brancher sur une prise reli e la terre Mod les gaz uniquement 11 V rifier que l alimentation en gaz est ouverte 12 V rifier l absence de fuites Tous les mod les 13 S lectionner un programme minut avec s chage chaud et mettre la s che
25. d installation suivantes sont applicables Les travaux d installation et r paration doivent tre ex cut s par un plombier ou tuyauteur qualifi ou licenci ou par le personnel qualifi d une entreprise licenci e par l tat du Massachusetts Si une vanne boisseau sph rique est utilis e elle doit comporter une manette Si un conduit de raccordement flexible est utilis sa longueur ne doit pas d passer 3 pi 17 EXIGENCES D INSTALLATION Outillage et pi ces Rassembler les outils et pi ces n cessaires avant de commencer l installation Lire et suivre les instructions fournies avec les outils indiqu s ici Pour toutes les installations Tournevis lame plate Pistolet calfeutrage et compos de calfeutrage pour l installation d un nouveau conduit d vacuation m Cl molette avec ouverture jusqu 1 25 mm ou cl douille hexagonale pour ajuster les pieds de la s cheuse Cisaille de ferblantier pour l installation d un nouveau Niveau conduit m Brides de serrage Tourne crou de 1 4 Couteau recommand m Pince M tre ruban Installations gaz Cl tuyau de 8 ou 10 Compos d tanch it des raccords filet s r sistant Cl mollette de 8 ou 10 au gaz propane pour le raccordement au gaz Pi ces fournies Mod les sans vapeur 4 pieds de nivellement Mod les vapeur UN 1 gt D
26. de plastique ou en feuille m tallique Utiliser un conduit d vacuation en m tal lourd de 4 102 mm et des brides de serrage eo Conduit d vacuation en m tal lourd de 4 102 mm On peut se procurer les produits d vacuation aupr s du marchand ou en t l phonant a Whirlpool Service Pour plus de renseignements voir la section Assistance ou service dans le Guide d utilisation et d entretien Conduit m tallique rigide Pour un meilleur rendement de s chage on recommande d utiliser des conduits m talliques rigides m On recommande d utiliser un conduit m tallique rigide pour r duire les risques d crasement et de d formation Conduit m tallique souple m Les conduits m talliques souples sont acceptables seulement dans la mesure o ils sont accessibles en vue du nettoyage Un conduit m tallique souple doit tre totalement d ploy et soutenu lorsque la s cheuse est sa position finale m Enlever tout exc s de conduit souple pour viter tout affaissement ou d formation susceptible de r duire la capacit d vacuation et le rendement m Ne pas installer le conduit m tallique flexible dans les cavit s ferm es des murs plafonds ou planchers m La longueur totale du conduit m tallique souple ne doit pas d passer 7 pi 2 4 m Coudes Les coudes 45 permettent une meilleure circulation de l air que les coudes 90 CL _ Y Meilleur Br
27. e cl pour serrer raccorder l alimentation en gaz la s cheuse Utiliser un compos d tanch it des tuyauteries sur tous les filetages m les non vas s Si on utilise un conduit m tallique souple veiller ce qu il ne soit pas d form Filetage m le vas B Filetage m le non vas REMARQUE Pour les raccordements au gaz de p trole liqu fi il faut utiliser un compos d tanch it des tuyauteries r sistant l action du gaz de p trole liqu fi Ne pas utiliser de ruban TEFLON T T TEFLON est une marque d pos e de Du Pont De Nemours et Compagnie 22 On doit utiliser une combinaison de raccords de tuyauterie pour raccorder la s cheuse l alimentation en gaz existante On voit ci dessous une illustration d un raccordement recommand Le raccordement peut varier selon le type la dimension et l emplacement de l alimentation B A Connecteur gaz souple de 3 8 B Conduit de la s cheuse de 3 8 C Coude de conduit de 3 8 3 8 D Adaptateur entre le conduit et le joint conique de 3 8 Ouvrir le robinet d arr t du conduit d alimentation Le robinet est ouvert lorsque la poign e est parall le au conduit d alimentation en gaz A Robinet ferm B Robinet ouvert V rifier tous les raccordements en les badigeonnant d une solution de d tection des fuites non corrosive approuv e L apparition de bulles indique une fuite R par
28. e ou d autres vapeurs ou liquides inflammables proximit de cet appareil ou de tout autre appareil lectrom nager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ e Ne pas tenter d allumer un appareil e Ne pas toucher un commutateur lectrique ne pas utiliser le t l phone se trouvant sur les lieux e Evacuer tous les gens de la pi ce de l difice ou du quartier e Appeler imm diatement le fournisseur de gaz du t l phone d un voisin Suivre ses instructions d faut de joindre votre fournisseur de gaz appeler les pompiers L installation et entretien doivent tre effectu s par un installateur qualifi une agence de service ou le fournisseur de gaz AVERTISSEMENT L odorat ne permet pas toujours la d tection d une fuite de gaz Les distributeurs de gaz recommandent l emploi d un d tecteur de gaz homologation UL ou CSA Pour d autre information contacter le fournisseur de gaz local En cas de d tection d une fuite de gaz ex cuter les instructions Que faire dans le cas d une odeur de gaz IMPORTANT L installation du gaz doit se conformer aux codes locaux ou en l absence de codes locaux au code canadien d installation B149 1 du gaz naturel ou du propane La s cheuse doit tre lectriquement reli e la terre conform ment aux codes locaux ou en l absence de codes locaux au Code canadien de l lectricit CSA C22 1 Dans l tat du Massachusetts les instructions
29. ectrical shock It is your responsibility representative or personnel if you are in doubt as to contact a qualified electrical installer whether the dryer is properly grounded Do not modify the m To be sure that the electrical connection is adequate and plug provided with the dryer if it will not fit the outlet have in conformance with the Canadian Electrical Code C22 1 latest a proper outlet installed by a qualified electrician edition and all local codes A copy of the above codes standard SAVE THESE INSTRUCTIONS may be obtained from Canadian Standards Association 178 Rexdale Blvd Toronto ON M9W 1R3 CANADA To supply the required 4 wire single phase 120 240 volt 60 Hz AC only electrical supply on a separate 30 amp circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended Connect to an individual branch circuit This dryer is equipped with a CSA International Certified Power Cord intended to be plugged into a standard 14 30R wall receptacle The cord is 5 ft 1 52 m in length Be sure wall receptacle is within reach of dryer s final location UU 4 wire receptacle 14 30R If using a replacement power supply cord it is recommended that you use Power Supply Cord Replacement Part Number 9831317 GAS DRYER oo HOOKUP Lengths over 20 ft 6 1 m should use larger tubing and Gas Supply Requirements a different size adapter fitting If your dryer has be
30. elles la grille de sortie Utiliser une seule feuille d assouplissant par charge et l utiliser une seule fois Le conduit d vacuation a t il la longueur appropri e V rifier que le conduit d vacuation n est pas trop long ou ne comporte pas trop de changements de direction Un long conduit augmentera les dur es de s chage Voir Instructions d installation m Le diam tre du conduit d vacuation a t il la taille correcte Utiliser un composant de 4 102 mm de diam tre La s cheuse est elle install e dans une pi ce o la temp rature est inf rieure 45 F 7 C Un bon fonctionnement des programmes de la s cheuse exige des temp ratures sup rieures 45 F 7 C 30 NOTES 31 W10261614A W10267631A SP 11 09 2009 Whirlpool Corporation A All rights reserved Printed in U S A
31. en converted to use LP gas 3 8 LP A compatible copper tubing can be used If the total length WARN NG of the supply line is more than 20 ft 6 1 m use larger pipe NOTE Pipe joint compounds that resist the action of LP gas must be used Do not use TEFLON tape Must include a shutoff valve In the U S A An individual manual shutoff valve must be installed within six 6 Explosion Hazard feet 1 8 m of the dryer in accordance with the National Fuel Use new CSA International approved gas supply line Gas Code ANSI 2223 1 The location should be easy to reach i for opening and closing Install a shut off valve Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 13 330 mm water column Examples of a qualified person include B D licensed heating personnel do nie plugged authorized gas company personnel fitting p D 1 2 NPT gas supply line authorized service personnel E Gas shutoff valve Failure to do so can result in death explosion or fire Gas supply connection requirements Gas Type m Use an elbow and a 3 8 flare x 3 8 NPT adapter fitting Natural between the flexible gas connector and the dryer gas pipe atura gas as needed to avoid kinking This dryer is equipped for use with Natural gas It is design certified by CSA International for LP propane or butane gases with appropriate conversi
32. er toute fuite ventuelle EVACUATION Exigences concernant l vacuation A AVERTISSEMENT Risque d incendie Utiliser un conduit d vacuation en m tal lourd Ne pas utiliser un conduit d vacuation en plastique Ne pas utiliser un conduit d vacuation en feuille de m tal Le non respect de ces instructions peut causer un d c s ou un incendie AVERTISSEM ENT Pour r duire le risque d incendie cette s cheuse DOIT EVACUER L AIR L EXTERIEUR IMPORTANT Observer les dispositions de tous les codes et r glements en vigueur Le conduit d vacuation de la s cheuse ne doit pas tre connect une vacuation de gaz une chemin e un mur un plafond ou un vide de construction Seul un conduit m tallique rigide ou souple doit tre utilis pour l vacuation En cas d utilisation du syst me d vacuation existant liminer la charpie sur toute la longueur du syst me et veiller ce que le clapet de d charge ne soit pas obstru par une accumulation de charpie Remplacer tout conduit de plastique ou de feuille m tallique par un conduit de m tal lourd rigide ou souple Examiner le tableau du conduit d vacuation Apporter les modifications n cessaires au syst me d vacuation pour atteindre le meilleur rendement de s chage En cas de nouveau syst me d vacuation Mat riel pour l vacuation Utiliser un conduit d vacuation en m tal lourd Ne pas utiliser un conduit
33. es normes applicables aux connecteurs utilis s avec des appareils m nagers gaz CSA 6 10 T TEFLON est une marque d pos e de E I Du Pont De Nemours et Compagnie 21 Exigences concernant l alimentation du br leur Altitudes sup rieures a 10 000 pi 3048 m Lors d une installation au dessus de 10 000 pi 3 048 une r duction de 4 du d bit thermique en BTU indiqu sur la plaque signal tique est n cessaire pour chaque tranche de 1 000 pi 305 m d l vation preuve sous pression de l alimentation en gaz m La s cheuse doit tre d connect e du syst me de canalisations d alimentation en gaz lors de tout test de pression des pressions sup rieures gt b po Canalisation d arriv e de gaz de la s cheuse La canalisation d arriv e de gaz sortant l arri re de la s cheuse est dot e d un filetage m le de 3 674 159 12 38 mm A Canalisation d arriv e de gaz NPT de 1 2 B Tuyau NPT de la s cheuse de 3 8 REMARQUE Si la s cheuse est mont e sur un pi destal pr voir 10 254 mm ou 15 5 894 mm de plus a partir du sol pour la hauteur de la canalisation d arriv e de gaz en fonction du mod le de pi destal Pour une installation dans un garage pr voir 18 460 mm de plus a partir du sol pour la hauteur de la canalisation d arriv e de gaz Raccordement au gaz 1 Retirer le capuchon rouge de la conduite de gaz 2 l aide d un
34. hoisir le syst me qui convient le mieux votre installation Deux installations d gagement r duit sont illustr es Voir les instructions du fabricant A B Installation au dessus de la s cheuse galement disponible avec un coude d cal B Installation avec p riscope REMARQUE On peut acheter les trousses suivantes pour les installations o le d gagement est r duit Voir la section Assistance ou service in your Use and Care Guide pour commander Installation au dessus de la s cheuse Pi ce num ro 4396028 Installation avec p riscope pour utilisation en cas de non concordance de la bouche de d charge de la s cheuse avec la bouche d vacuation murale Pi ce num ro 4396037 Non concordance de 0 0 mm 18 460 mm Pi ce num ro 4396011 Non concordance de 18 460 mm 29 737 mm Pi ce num ro 4396014 Non concordance de 29 737 mm 50 1270 mm Dispositions sp ciales pour les installations dans une maison mobile Le syst me d vacuation doit tre solidement fix une section non combustible de la structure de la maison mobile et ne doit pas se terminer en dessous de la maison mobile Acheminer le conduit d vacuation vers l ext rieur D terminer l itin raire d acheminement du conduit Choisir l itin raire d acheminement vers l ext rieur qui sera le plus direct et le plus rectiligne Planifier l installation pour introduire le no
35. ides de serrage m Utiliser des brides de serrage pour sceller tous les joints Le conduit d vacuation ne doit pas tre connect ou fix avec des vis ou avec tout autre dispositif de serrage qui se prolonge l int rieur du conduit Ne pas utiliser de ruban adh sif pour conduit Bride de serrage vacuation A et Styles de clapets recommand s Style de clapet acceptable B 4 102 102 mm 2 te mm 102 mm A Style de clapet persiennes B Style de clapet de type bo te C Style de clapet inclin Terminer le conduit d vacuation par un clapet de d charge pour emp cher les rongeurs et insectes d entrer dans l habitation 23 Le clapet de d charge doit tre situ au moins 12 305 mm au dessus du sol ou de tout autre objet susceptible de se trouver sur le trajet de l air humide rejet par exemple fleurs roches ou arbustes limite de la neige etc pas utiliser un clapet d vacuation fermeture magn tique Une mauvaise vacuation de l air peut causer de l humidit et une accumulation de charpie l int rieur de la maison ce qui peut provoquer Dommages par l humidit aux boiseries meubles peinture papier peint tapis etc m Probl mes de nettoyage dans la maison et probl mes de sant Planification du syst me d vacuation Choisir un type de syst me d vacuation Installations d vacuation recommand
36. in Y connector 4 ft 1 2 m of dryer and water pressure of 20 100 psi C Short inlet hose Rubber washer i 137 9 689 6 kPa Cold water supply may come from Remove parts package from dryer drum Check that all parts washer using connector provided are included Do not operate your dryer at temperatures below 45 F 7 C NOTE Do not use leveling legs supplied with dryer if installing At lower temperatures the dryer might not shut off at the on a pedestal of an automatic sensor cycle This can result in longer drying times The dryer must not be installed or stored in an area where it will Parts needed be exposed to water and or weather Check local codes Check existing electrical supply and venting Check code requirements Some codes limit or do not permit See Electrical Requirements and Venting Requirements before installation of the dryer in garages closets mobile homes purchasing parts or sleeping quarters Contact your local building inspector Mobile home installations require metal exhaust system hardware available for purchase from the dealer from whom you purchased your dryer For further information please refer to the Assistance or Service section in your Use and Care Guide Installation clearances The location must be large enough to allow the dryer door to open fully Dryer Dimensions 431 2 1105 221 4 _ gt 565 mm a 737 mm N
37. its final location Do not crush or kink vent On gas models Check that there are no kinks in the flexible gas line Once the exhaust vent connection is made remove the corner posts and cardboard CONNECT INLET HOSE STEAM MODELS The dryer must be connected to the cold water faucet using the new inlet hoses Do not use old hoses 1 2 Turn cold water faucet off and remove washer inlet hose Remove old rubber washer from inlet hose and replace with new rubber washer provided If space permits attach the brass female end of the Y connector to the cold water faucet NOTE ff Y connector can be attached directly to cold water faucet go to Step 6 If Y connector cannot be attached directly to the cold water faucet the short hose must be used Continue with Step 3 Attach short hose to cold water faucet Screw on coupling by hand until it is seated on faucet Using pliers tighten the couplings with an additional two thirds turn NOTE Do not overtighten Damage to the coupling can result Attach Y connector to brass male end of small hose Screw on coupling by hand until it is seated on connector One end of the long hose has a wire mesh strainer inside the coupling Attach this end to the Y connector Attach washer cold inlet hose to other end of Y connector Screw on coupling by hand until it is seated on connector A A Inlet to cold water 8 Using pliers tighten the cou
38. materials If flexible metal foil type duct is installed it must be of a specific type identified by the appliance manufacturer as suitable for use with clothes dryers Flexible venting materials are known to collapse be easily crushed and trap lint These conditions will obstruct clothes dryer airflow and increase the risk of fire To reduce the risk of severe injury or death follow all installation instructions Save these instructions WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS e Do not try to light any appliance e Do not touch any electrical switch do not use any phone in your building e Clear the room building or area of all occupants e Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions e If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that you use a gas detector approved by UL or CSA For more information contact your gas supplier If a gas leak is detected follow the What to do if you
39. mber of elbows and turns When using elbows or making turns allow as much room as possible Bend vent gradually to avoid kinking m Use the fewest 90 turns possible Determine vent length and elbows needed for best drying performance Use the following vent system chart to determine type of vent material and hood combinations acceptable to use NOTE Do not use vent runs longer than those specified in the Vent system chart Exhaust systems longer than those specified will Shorten the life of the dryer m Reduce performance resulting in longer drying times and increased energy usage The vent system chart provides venting requirements that will help to achieve the best drying performance Vent system chart NOTE Side and bottom exhaust installations have a 90 turn inside the dryer To determine maximum exhaust length add one 90 turn to the chart Number Type of vent Louvered Angled 90 elbows hoods hoods 0 Rigid metal 64 ft 20 m 58ft 17 7 1 Rigid metal 54 ft 16 5 m 48 ft 14 6 m 2 Rigid metal 44 ft 13 4 m 38 ft 11 6 m 3 Rigid metal 35 ft 10 7 m 29 ft 8 8 m 4 Rigid metal 27 ft 8 2 m 21 ft 6 4 m Install Vent System Install exhaust hood Use caulking compound to seal exterior wall opening around exhaust hood Connect vent to exhaust hood Vent must fit inside exhaust hood Secure vent to exhaust hood with 4 102 mm clamp Run vent to dryer
40. mbre minimal de coudes et de changements de direction m Sides coudes ou changements de direction sont utilis s pr voir autant d espace que possible Plier le conduit graduellement pour viter de le d former Utiliser le moins possible de changements de direction 90 D terminer la longueur du conduit et les coudes n cessaires pour la meilleure performance de s chage Utiliser le tableau des syst mes d vacuation ci dessous pour d terminer le type de composants et les combinaisons acceptables REMARQUE Ne pas utiliser un conduit de longueur sup rieure la valeur sp cifi e dans le tableau des syst mes d vacuation Si la longueur du circuit est sup rieure la valeur sp cifi e dans le tableau on observera Une r duction de la long vit de la s cheuse Une r duction du rendement avec temps de s chage plus longs et une plus grande consommation d nergie Le tableau des syst mes d vacuation fournit les exigences d vacuation qui vous aideront atteindre la meilleure performance de s chage Tableau des syst mes d vacuation REMARQUE Les conduits d vacuation par le c t et par le bas comportent un changement de direction 90 l int rieur de la s cheuse Pour d terminer la longueur maximale du conduit ajouter un changement de direction 90 de plus dans le tableau Nombre de Type de Clapets de Clapets changements de conduit type bo te inclin
41. n lectrique homologu par la CSA International introduire dans une prise murale standard 14 30R Le cordon mesure 5 pi 1 52 m Veiller ce que la prise murale se trouve proximit de l emplacement d finitif de la s cheuse UU Prise murale a 4 fils 14 30R En cas d utilisation d un cordon d alimentation de rechange il est recommand d utiliser le cordon d alimentation lectrique num ro 9831317 pi ce de rechange 20 Pour en savoir plus veuillez vous reporter aux num ros de service qui se trouvent a la section Assistance ou service dans le Guide d utilisation et d entretien INSTRUCTIONS DE LIAISON A LA TERRE Pour une s cheuse reli e la terre et connect e par un cordon Cette s cheuse doit tre reli e a la terre En cas de mauvais fonctionnement ou de panne la liaison a la terre r duira le risque de choc lectrique en offrant au courant lectrique un acheminement d vacuation de moindre r sistance Cette s cheuse est aliment e par un cordon lectrique comportant un conducteur reli a la terre et une fiche de branchement munie d une broche de liaison la terre La fiche doit tre branch e sur une prise appropri e qui est bien install e et reli e la terre conform ment tous les codes et r glements locaux AVERTISSEMENT Le raccordement incorrect de cet appareil au conducteur de liaison la terre peut susciter un risque de choc lectrique E
42. n cas de doute quant la qualit de liaison la terre de la s cheuse consulter un lectricien ou un technicien ou un personnel qualifi Ne pas modifier la fiche de branchement fournie avec la s cheuse si la fiche ne correspond pas la configuration de la prise de courant demander un lectricien qualifi d installer une prise de courant appropri e CONSERVEZ CES INSTRUCTIONS RACCORDEMENT DE L ALIMENTATION A LA SECHEUSE A GAZ Alimentation en gaz A AVERTISSEMENT Risque d explosion Utiliser une canalisation neuve d arriv e de gaz approuv e par CSA International Installer un robinet d arr t Bien serrer chaque organe de connexion de la canalisation de gaz En cas de connexion au gaz propane demander une personne qualifi e de s assurer que la pression de gaz ne d passe pas 330 mm 13 po de la colonne d eau Par personne qualifi e on comprend le personnel autoris de chauffage le personnel autoris d une compagnie de gaz et le personnel d entretien autoris Le non respect de ces instructions peut causer un d c s un explosion ou un incendie Type de gaz Gaz naturel Cette s cheuse est quip e pour une alimentation au gaz naturel Sa conception est homologu e par CSA International pour l alimentation au gaz de p trole liqu fi propane ou butane avec conversion appropri e Cette s cheuse doit tre quip e du br leur convenable correspond
43. not use plastic or metal foil vent 4 102 mm heavy metal exhaust vent and clamps must be used a ny 4 102 mm heavy metal exhaust vent Vent products can be purchased from your dealer or by calling Whirlpool Service For more information see the Assistance or Service section in your Use and Care Guide Rigid metal vent m For best drying performance rigid metal vents are recommended Rigid metal vent is recommended to avoid crushing and kinking Flexible metal vent Flexible metal vents are acceptable only if accessible for cleaning Flexible metal vent must be fully extended and supported when the dryer is in its final location m Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance Do not install flexible metal vent in enclosed walls ceilings or floors The total length of flexible metal vent should not exceed 7 ft 2 4 Elbows 45 elbows provide better airflow than 90 elbows j Good Better Clamps Use clamps to seal all joints m Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the duct and catch lint Do not use duct tape Clamp Exhaust A and Recommended hood styles C Acceptable hood style B 4 C 102 mm 102 mm 212 qu mm 102 mm A Louvered hood style B Box hood style C Angled
44. on m This dryer must be connected to the gas supply line with Your dryer must have the correct burner for the type of gas a listed flexible gas connector that complies with the standard in your home Burner information is located on the rating plate for connectors for gas appliances ANSI 221 24 or CSA 6 10 in the door well of your dryer If this information does not agree Use only pipe joint compound Do not use TEFLON tape with the type of gas available contact your dealer or call Burner input requirements the phone numbers referenced in the Assistance or Service section in your Use and Care Guide Elevations above 10 000 ft 3 048 m LP gas conversion When installed above 10 000 ft 8 048 a 4 reduction of the burner Btu rating shown on the model serial number plate Conversion must be made by qualified technician is required for each 1 000 ft 305 m increase in elevation No attempt shall be made to convert the appliance from the gas specified on the model serial rating plate for use with a different gas Gas supply pressure testing without consulting your gas company The dryer must be disconnected from the gas supply piping system during pressure testing at pressures greater than 1 2 psi Gas supply line Must include 1 8 NPT minimum plugged tapping accessible for test gauge connection immediately upstream of the gas connection to the dryer See illustration m 1 2 IPS pipe is recommended
45. oor and the hinges by lifting upward on the door Lay the door on a flat protected surface with the inside of the door facing up Remove remaining 2 loose screws from dryer front panel 5 Remove the 4 plastic plugs located outside the dryer door opening 6 Install 4 plastic plugs into screw holes in the dryer left where the hinges were removed in Step 4 Reverse the strike 1 Remove the door strike from the dryer door opening 2 Remove the cosmetic screw opposite the door strike A Door strike B Cosmetic screw 3 Reinstall the door strike and cosmetic screw on the opposite side of dryer door opening from where they were removed NOTE Door strike and plugs must be on the same side of the dryer door opening Reinstall the door 1 Remove the 4 screws and 2 hinges from the dryer door 2 Replace the 4 screws in the same holes 3 Remove the 4 screws from the opposite side of the door Qi ir Ss SS _ 8 8 8 gt Install the 2 hinges to the front panel of the dryer using 4 screws Use the non slotted side to attach the hinge to the front panel 5 Install screws in top hinge holes in the door Do not tighten screws Leave approximately 1 4 6 mm of screw exposed 13 Hang door by placing screw heads into top slotted holes of hinges and slide door down Align bottom screw holes in hinge and door Install two bottom screws Tighten all hinge screws
46. plings an additional two thirds turn NOTE Do not overtighten Damage to the coupling can result 11 9 Attach other end of long hose to fill valve at bottom of dryer back panel Screw on coupling by hand until it is seated on fill valve connector qT 10 Using pliers tighten the coupling an additional two thirds turn NOTE Do not overtighten Damage to the coupling can result 11 Check that the water faucets are on 12 Check for leaks around Y connector faucet and hoses LEVEL DRYER Check the levelness of the dryer by first placing a level on the top of the dryer near the console Then by placing a level in the crease on the side of the dryer between the top of the dryer and the dryer cabinet check the levelness from front to back If the dryer is not level prop up the dryer using a wood block Use a wrench to adjust the legs up or down and check again for levelness 12 COMPLETE INSTALLATION 1 Check that all parts are now installed If there is an extra part go back through the steps to see which step was skipped 2 Check that you have all of your tools 3 Dispose of recycle all packaging materials 4 Check the dryer s final location Be sure the vent is not crushed or kinked 5 Check that the dryer is level See Level Dryer 6 Remove the blue film on the console and any tape remaining on the dryer 7 Wipe the dryer drum interior thoroughly
47. rni res et glisser la porte vers le bas Aligner les trous de vis inf rieurs dans la charni re et la porte Fixer deux vis inf rieures Serrer toutes les vis de la charni re 7 Fermer la porte v rifier l engagement de la g che D PANNAGE Essayer d abord les solutions sugg r es ici ce qui vous vitera peut tre le co t d une visite de service Fonctionnement de la s cheuse Le s cheuse ne fonctionne pas m Un fusible est il grill ou un disjoncteur s est il d clench Remplacer le fusible ou r enclencher le disjoncteur Il peut y avoir 2 fusibles ou disjoncteurs pour la s cheuse lectrique V rifier que les deux fusibles sont intacts et serr s ou que les deux disjoncteurs ne se sont pas d clench s Si le probl me persiste appeler un lectricien Remplacer le fusible ou r enclencher le disjoncteur Une alimentation lectrique correcte est elle disponible Les s cheuses lectriques n cessitent une alimentation lectrique de 240 V V rifier avec un lectricien qualifi A t on utilis un fusible ordinaire Utiliser un fusible temporis Absence de chaleur Un fusible est il grill ou un disjoncteur s est il d clench Le tambour peut tourner mais sans chaleur Les s cheuses lectriques utilisent 2 fusibles ou disjoncteurs Remplacer le fusible ou r enclencher le disjoncteur Si le probl me persiste appeler un lectricien La s che
48. rt d air ext rieur telle qu une fen tre proximit doit tre au moins deux fois plus grande que l ouverture de d charge de la s cheuse Pour les s cheuses a gaz Trousse d installation pour maison mobile Pi ce n 346764 Voir la section Outillage et pi ces pour des renseignements sur la commande 19 RACCORDEMENT DE L ALIMENTATION A LA SECHEUSE ELECTRIQUE Sp cifications lectriques A AVERTISSEMENT Risque de choc lectrique Brancher sur une prise a 4 alv oles reli e a la terre Le non respect de cette instruction peut causer un d c s ou un choc lectrique C est l utilisateur qu incombe la responsabilit de Contacter un lectricien qualifi S assurer que le raccordement lectrique est ad quat et conforme au code national de l lectricit C22 1 derni re dition et tous les codes locaux Pour obtenir un exemplaire des normes des codes ci dessus contacter Canadian Standards Association 178 Rexdale Blvd Toronto ON M9W 1R3 CANADA L appareil doit tre aliment uniquement par une alimentation lectrique monophas e de 120 240 V CA seulement 60 Hz 4 fils sur un circuit s par de 30 amp res prot g e par fusible aux deux extr mit s de la ligne On recommande d utiliser un fusible ou un disjoncteur temporis On recommande galement que cet appareil soit aliment par un circuit ind pendant Cette s cheuse est quip e d un cordo
49. sorserstevstentensndssncvsenssiesenssnesss 12 COMPLETE INSTALLATION 12 REVERSE DOOR SWING nnna 12 TROUBLESHOOTING Fe cses 14 Diver Operation ee ressentie 14 Dryer ites 15 W10261614A W10267631A SP TABLE DES MATIERES S CURIT DE LA SECHEUSE ssssssssssssesssssestessteesteesatesnaes 16 EXIGENCES 18 Outillage et pi ces 18 quipement facultatif 18 Exigences d emplacement 18 RACCORDEMENT DE L ALIMENTATION LA SECHEUSE ELECTRIQUE i csiscscectsencsteseiceasscesccsccccustiendsuadieracesiese 20 Sp cifications lectriques 20 RACCORDEMENT DE L ALIMENTATION LA SECHEUSE A GAZ mnrnrnmnnnnnnmnnnnnnnnnnnnnnnnrere 21 Alimentation en gaz 21 Raccordement au gaz 22 EVACUATIONS ne 23 Exigences concernant 23 Planification du syst me d vacuation 24 Installation du syst me 25 INSTALLATION DES PIEDS DE NIVELLEMENT 25 RACCORDEMENT DU CONDUIT D EVACUATION 26 RACCORDEMENT DES TUYAUX D ALIMENTATION MODELES
50. taller la g che de la porte et la vis cosm tique sur le c t oppos de leur place initiale REMARQUE La g che de la porte et les chevilles d obturation doivent tre sur le m me c t de l ouverture de la porte R installation de la porte 1 Retirer les quatre vis et les deux charni res de la porte de la s cheuse 2 Replacer les quatre vis dans les m mes trous A Desserrer ces vis B Oter ces vis 4 Retirer la porte de la s cheuse et les charni res en les soulevant a la verticale Poser la porte sur une surface plane prot g e c t int rieur partie interne de la porte vers le haut Retirer les deux vis desserr es du panneau avant de la s cheuse 5 Retirer les quatre chevilles de plastique situ es l ext rieur de l ouverture de la porte de la s cheuse H A gt 4 Installer les deux charni res sur le panneau avant gt o de la s cheuse l aide de quatre vis Utiliser le c t sans fente pour fixer la charni re sur le panneau avant 6 Installer 4 chevilles de plastique dans les trous des vis sur la gauche de la s cheuse apr s avoir retir les charni res Etape 4 28 5 Installer les vis dans les trous sup rieurs de la porte destin s la pose des charni res Ne pas serrer les vis Laisser les vis en retrait d environ 1 4 6 mm 6 Suspendre la porte ins rer les t tes de vis dans les trous de fente sup rieurs des cha
51. u de blessure grave si vous A AVE RTISSE ME NT ne suivez pas les instructions Tous les messages de s curit vous diront quel est le danger potentiel et vous disent comment r duire le risque de blessure et ce qui peut se produire en cas de non respect des instructions AVERTISSEMENT Risque d incendie Linstallation de la s cheuse linge doit tre effectu e par un installateur qualifi Installer la s cheuse conform ment aux instructions du fabricant et aux codes locaux Ne pas installer de s cheuse a linge avec des mat riaux d vacuation en plastique souple Si un conduit m tallique souple de type papier d aluminium est install celui ci doit tre d un type sp cifique identifi par le fabricant de l appareil et convenir une utilisation avec les s cheuses linge Les mat riaux d vacuation souples sont connus pour s affaisser tre facilement cras s et bloquer la charpie Ces situations obstrueront le d bit d air de la s cheuse linge et augmenteront le risque d incendie Pour r duire le risque de blessure grave ou de d c s suivre toutes les instructions d installation Conserver ces instructions AVERTISSEMENT Pour votre s curit les renseignements dans ce manuel doivent tre observ s pour r duire au minimum les risques d incendie ou d explosion ou pour viter des dommages au produit des blessures ou un d c s Ne pas entreposer ou utiliser de essenc
52. ure 1 Afin d viter d endommager le plancher utiliser une grande pi ce de carton de la bo te de la s cheuse Placer la pi ce de carton sous toute la longueur du bord arri re de la s cheuse 25 2 Saisir fermement la s cheuse par la caisse ni par le dessus ni par le panneau de commande D poser d licatement la s cheuse sur le carton Voir l illustration 3 Examiner les pieds de nivellement Trouver le symbole de rep rage losange 4 Engager manuellement les pieds dans les trous pr vus cet effet Utiliser une cl molette pour visser les pieds jusqu ce que le symbole de rep rage losange ne soit plus visible 5 Placer une corni re en carton sous chacun des deux coins arri re de la s cheuse Placer la s cheuse debout Glisser la s cheuse sur les corni res jusqu ce que l appareil soit proche de son emplacement final Laisser assez d espace pour connecter le conduit d vacuation RACCORDEMENT DU CONDUIT D EVACUATION 1 l aide d une bride de serrage de 4 102 mm relier le conduit d vacuation la bouche d vacuation de la s cheuse Si on utilise un syst me d vacuation existant s assurer qu il est propre Le conduit d vacuation de la s cheuse doit tre fix sur la bouche d vacuation de la s cheuse et dans le clapet d vacuation S assurer que le conduit d vacuation est fix au clapet d vacuation l aide d une bride de serrage de 4 102 mm 2
53. ure Pliers Explosion Hazard Gas Installations Keep flammable materials and vapors such as m 8 or 10 pipe wrench Pipe joint compound gasoline away from dryer 8 or 10 adjustable wrench resistant to LP gas Place dryer at least 18 inches 460 mm above the floor for gas connections for a garage installation Failure to do so can result in death explosion or fire Parts supplied Non Steam Models You will need A location that allows for proper exhaust installation See Venting Requirements 4 Leveling legs A separate 30 amp circuit If you are using a power supply cord a grounded electrical outlet located within 2 ft 610 mm of either side of the dryer Steam Models See Electrical Requirements A sturdy floor to support the total dryer weight of 200 Ibs 90 7 kg The combined weight of a companion appliance should also be considered level floor with a maximum slope of 1 25 mm under entire dryer If slope is greater than 1 25 mm install Extended Dryer Feet Kit Part Number 279810 Clothes may not tumble properly and automatic sensor cycles may not operate correctly if dryer is not level lt Fora garage installation you will need to place the dryer at least 18 460 mm above the floor If using a pedestal you will need Q A B C D E 18 460 mm to the bottom of the dryer a 4 D right angle m Steam models only Cold water faucets located with
54. use affiche un message cod PF panne de courant v rifier ce qui suit Le programme de s chage a t il t interrompu par une panne de courant Appuyer sans relacher sur START PAUSE mise en marche pause pour remettre la s cheuse en marche Essayer de r soudre le probl me de la fa on suivante V rifier si un fusible est grill ou si un disjoncteur s est d clench Les s cheuses lectriques utilisent deux fusibles ou disjoncteurs Remplacer le fusible ou r enclencher le disjoncteur V rifier que le cordon d alimentation lectrique est bien install S lectionner un programme de s chage minut avec chaleur et remettre la s cheuse en marche Si le message reste affich consulter un lectricien qualifi m Codes de service variables F1E1 F2E2 F3E1 F3E2 F7E1 F3E6 F3E7 Faire un appel de service Pour tous les mod les sans fen tre d affichage Si le t moin lumineux mouille WET clignote et tous les autres t moins lumineux de la console sont teints Faire un appel de service 29 R sultats de la s cheuse AVERTISSEMENT Le s chage des v tements n est pas satisfaisant les dur es de s chage sont trop longues ou la charge est trop chaude Le filtre charpie est il obstru de charpie Le filtre charpie doit tre nettoy avant chaque charge Risque d explosion AVERTISSEMENT Garder les mati res et les vapeurs inflammables telle
55. use en marche Ne pas s lectionner le r glage Air Only air seulement Si la s cheuse ne d marre pas v rifier ce qui suit m Les commandes sont r gl es la position de marche ou On m La bouton Start mise en marche a t enfonc fermement La s cheuse est branch e dans une prise et ou l alimentation lectrique est allum e Les fusibles du domicile sont intacts et serr s le disjoncteur n est pas d clench m La porte de la s cheuse est ferm e Cette s cheuse ex cute automatiquement une routine de diagnostic d installation au d but de son premier programme REMARQUE Il est possible que la s cheuse d gage une odeur lors du chauffage initial Cette odeur est normale lorsque l l ment chauffant est utilis pour la premi re fois Lodeur dispara tra a 27 Inversion de la g che INVERSION DU SENS aia ae de la porte D OUVERTURE DE LA PORTE Le sens d ouverture de la porte peut tre chang du c t droit au c t gauche si d sir 1 Placer une serviette ou un linge doux sur le dessus de la s cheuse ou du plan de travail pour emp cherd endommager la surface D pose de la porte 1 Ouvrir la porte de la s cheuse 2 Retirer la vis inf rieure de chacune des deux charni res qui fixent la porte au panneau avant de la s cheuse 3 Desserrer la vis sup rieure de chacune des deux charni res A G che de la porte de l tape 2 B Vis cosm tique 3 R ins
56. uyau en cuivre compatible avec le gaz de p trole liqu fi de 3 8 Si la longueur totale de la canalisation d arriv e de gaz est sup rieure 20 pi 6 1 utiliser une plus grosse conduite REMARQUE On doit utiliser un compos d tanch it des tuyauteries r sistant l action du gaz de p trole liqu fi Ne pas utiliser de ruban TEFLON Doit comporter un robinet d arr t du gaz Au Canada Un robinet d arr t manuel individuel doit tre install conform ment la norme B149 1 du Code des installations au gaz naturel ou propane On recommande que le robinet d arr t manuel individuel soit install moins de 6 pi 1 8 m de la s cheuse L emplacement doit tre facilement accessible pour l ouverture et la fermeture A C E A Connecteur de gaz souple de 3 8 B Adaptateur du tuyau au joint conique de 3 8 Connecteur obtur filetage NPT 1 8 ou plus D Canalisation d arriv e de gaz NPT de 1 2 Robinet d arr t du gaz Exigences concernant le raccordement au gaz Utiliser un coude et un adaptateur NPT de 3 8 x 3 8 entre le connecteur de gaz flexible et la conduite de gaz de la s cheuse tel que n cessaire pour viter le pincement Utiliser uniquement un compos d tanch it des tuyauteries Ne pas utiliser de ruban TEFLONS1 On doit raccorder la s cheuse la conduite d alimentation en gaz l aide d un connecteur de gaz flexible homologu qui respecte l
57. y Title 24 HUD Part 280 or Standard CAN CSA Z240 MH Mobile home installations require All Dryers m Metal exhaust system hardware which is available for purchase from your dealer Special provisions must be made in mobile homes to introduce outside air into dryer The opening such as a nearby window should be at least twice as large as the dryer exhaust opening For gas dryers Mobile Home Installation Kit Part Number 346764 See Tools and Parts section for information on ordering ELECTRIC DRYER POWER HOOKUP CANADA ONLY For further information please reference the service numbers Electrical Requirements located in the Assistance or Service section A WARNING GROUNDING INSTRUCTIONS m For a grounded cord connected dryer This dryer must be grounded In the event of malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This dryer is equipped with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or service Electrical Shock Hazard Plug into a grounded 4 prong outlet Failure to do so can result in death or el