1. clear conical prism lens assembly Electrical Thermally protected class P ballast C B M approved non PCB If K O is within 3 of ballast use wire suitable for at least 90 UL Listed for damp locations Labels B E W UL and ULc Listed This product may have a mercury containing lamp Manage in accord with Disposal Laws See www lamprecycle org For Factory Technical Information 978 657 7600 Fax 978 658 0595 631 Airport Road Fall River MA 02720 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2009 a Philips Group Section 5 Folio MA12 12 PHILIPS
2. 7 7600 Fax 978 658 0595 01 09 631 Airport Road Fall River MA 02720 e 508 679 8131 Fax 508 674 4710 We reserve the right to change details of design materials and finish www lightolier com 2009 a Philips Group Section 5 Folio MA12 12 PHILIPS LIGHTOLIER Skyway SKS2GPK214 or 224 Page 2 of 2 Model No SKS2GPK214UNVPG LER FP 56 4 IW 32 5 BF 1 05 Comparative yearly lighting energy cost per 1000 lumens 4 25 Report Number G2008325 Catalog Number SKS2GPK214UNVPG Lamps 2 F14T5 835 ALTO Luminaire Skyway Recessed 2 x 2 fixture prismatic acrylic lens assembly Ballast ICN 2S28 SC Report is based on 1200 Lumens per lamp Efficiency 72 8 CIE Type Direct Indirect Plane 0 Deg 90 Deg Spacing Criteria 1 2 1 3 Shielding Angles 90 90 Plane 0 Deg 90 Deg Luminous Length 21 600 21 600 COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0 20 CANDELA DISTRIBUTION ZONAL LUMEN SUMMARY LUMENS LAMP 568 23 7 927 38 6 487 62 0 746 0 746 ERAGE AVERAGE AVERAGE DEG 902 523 187 014 724 45 DEG 1973 1558 1202 975 686 90 DEG 1944 1453 1116 873 572 2 x 2 Recessed Fluorescent Tri Lens Frame Static or Air Supply Return 2 Lamp T5 or T5HO Model No SKS2GPK224UNVPG LER FP 52 4 IW 51 3 BF 1 0 Comparative yearly lighting energy cost per 1000 lumens 4 58 Report Number G2008179 Catalog Number S
3. G tt 24 Watt i NK For NYC Code Local 3 Manufactured ttProgram Rapid Start UNV only Options Accessories Fusing Internal fast blow fusing SUFFIX A Internal slow blow fusing SUFFIX C Drywall Kit Order Catalog Number FK92X2 Electrical Wiring Options Consult factory For motion or light sensor See Folio 0A20 10 and 0A20 30 Specifications continuned Specifications Performance In an installation of 2 lamp ratio of 1 with reflectance 80 ceiling 50 be less than 77 To reduce glare the avera 1202 candelas per square meter To contro in the 30 90 zone shall not be less than Air Handling SKA only side air passages for air supp air is discharged vertically Optional side c ed through the lamp compartment through Materials Chassis parts are die formed cod 14W luminaires in a room cavity wall 20 floor the C U shall not ge brightness at 65 shall not exceed veiling reflections luminaire output 67 4 y or air return Supply osure strips Air return is also provid fixture body ends e gauge cold rolled steel Housing has side rails hemmed over and housing ends t Finish Chassis exterior black baked po polyester enamel minimum 86 reflectance Rust preven Reflectors 95 reflective white powder rned in for safe handling yester enamel Cavity white baked ative undercoating coated Lightolier is a Philips group brand Lens Proprietary high quailty frost white acrylic and
4. KS2GPK224UNVPG Lamps 2 F24T5HO Luminaire Skyway Recessed 2 x 2 fixture prismatic acrylic lens assembly Ballast ICN 2S24 Report is based on 1800 Lumens per lamp Efficiency 74 6 CIE Type Direct Indirect CANDELA DISTRIBUTION Plane 0 Deg 90 Deg Spacing Criteria 1 2 1 3 Shielding Angles 90 90 Plane 0 Deg 90 Deg Luminous Length 21 600 21 600 COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE 0 20 ZONAL LUMEN SUMMARY LUMENS LAMP 885 24 6 1442 40 0 2301 63 9 2685 0 2685 LUMINANCE DATA IN CANDELA SQ METER AVERAGE AVERAGE AVERAGE AVERAGE IN DEG 0 DEG 45 DEG 90 DEG 45 2935 3043 3001 2310 2385 2223 1760 1815 1689 1450 1450 1322 991 914 800 55 65 75 85 Ordering Information Explanation of Catalog Number Example SKS2GPK214UNVPG Skyway Body Style Fixture Ceiling Type Side Lens Center Lens Lamp Lamp Voltage Options Recessed S Static Width G Standar P Frost White K Pattern 19 Quantity By Others 120 277 or Add appropriate Fluorescent A Air Grid Acrylic Lens 156 Virgin 2 2 Lamp 14 15 14W UNV 120 277 suffix to catalog T Slot Gri Acyrlic Lens 24 T5HO 24W no ie A Nominal 24 Ballast Type lt 20THD lt 10THD SK standard say 2 Lamp Elec T5 PGH 14 Watt SY For NYC Code B E W Manufactured 2 Lamp Elec TSHO P
5. LIGHTOLIER Page 1 of 2 Features Aesthetically pleasing triple lens design Curved high light transmission frost white acrylic side lenses Clear acrylic conical prismatic center lens Internal reflector coated with 95 reflective white paint 72 8 efficient 2 Lamp 14 watt T5 74 6 efficient 2 Lamp 24 watt T5HO 5 deep body Black housing exterior for cooler ballast operating temperature Eyeleted heat removal vents in fixture ends Hemmed over side rails for maximum safety Fixture ends turned in for safe handling Built in earthquake clips patent no 5 072 344 Door jamb finished black on four sides for positive light stop True mitered corner aluminum lens frame Spring loaded rooster head latches 18 gauge steel hinges Skyway SKS2GPK214 or 224 2 x 2 Recessed Fluorescent Tri Lens Frame Static or Air Supply Return 2 Lamp T5 or T5HO Construction to meet NYC Code Requirements or Chicago Plenum is available Mounting Methods Exposed Slot T grid ceiling Support by others Fixture Drywall Kit lt See Options A rywall by others earthquake clip installed lay in grid Drywall Kit Catalog Number FK92X2 Lightolier is a Philips group brand Dimensions 24 610mm Air supply slots SKA Only 2 X 2 1 2 Access Plate with 2 7 8 73mm Dia KO s Job Information Job Name Cat No Lamp s Volts Ballast For Factory Technical Information 978 65
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 e 自警ネットワーク研究会認定 監視ソフトウェア 代理 EYE software EMC® Documentum® TaskSpace TaxScripts® TaxPro User Manual UT4000 Series Digital Storage Oscilloscope User Manual 省スペース型電子式電力量計 (SMシリーズ:単独計器) 取扱説明書 Samsung Багатофункціональний пристрій SCX-4200 Керівництво користувача transversale n°12 - amérique du sud - site Copyright © All rights reserved.