Home

LG Dehumidifier 115V User's Manual

image

Contents

1. If the unit experiences a loss of power which can result from a power inter ruption or overheating we recommend you let the unit sit off for five minutes before restarting Otherwise it might shut off again READ AND SAVE THESE INSTRUCTIONS How To USE THE ToUCHPAD ConTROL KEYS DRIEAZ The Touchpad on the Evolution LGR has one display and four keys The normal display messages are DEHUMIDIFIER OFF CMPRSR DELAY DEHUMIDIFIER ON PUMP PURGING ER TOTAL HRS DEFROST ON JOB HRS GET SERVICE ERO1 When you first plug in the unit the touchpad display will cycle con tinuously through three messages DEHUMIDIFER OFF TOTAL HOURS and JOB HOURS Illustration of Touchpad Cle ON OFF Press the ON OFF key to turn the unit on or off When turning the machine on usually the display reads CMPRSR DELAY and performs a numeral count down from a maximum of 60 seconds to 0 The compressor delay gives the machine time to warm up when needed If you don t see a compressor delay countdown the machine is ready to go Once the unit completes the CMPRSR DELAY the display reads DEHUMIDIFIER ON and continues to cycle between TOTAL HOURS JOB HOURS and DEHUMIDIFIER ON Press the ON OFF key again to turn the unit off The display will read DEHUMIDIFIER OFF DISPLAY Press the DISPLAY key to stop the display at DEHU MIDIFER ON or OFF TOTAL HOURS or JOB HOURS as it cycles Press DISPLAY again to re start the display cycle Ho
2. Maintenance A WARNING wz ELECTRIC SHOCK HAZARD Unplug any DrizAir dehumidifier before performing maintenance MAINTENANCE INTERVALS Before Each Use e Inspect the electrical cord for damage Look for fraying cuts etc Do not use the unit if you find any Call Dri Eaz for the nearest Service Center e Inspect filter Look for accumulated dust and dirt that would restrict airflow through the filter into the unit If any is visible vacuum out the debris Do not wash the filter as it will reduce the effectiveness of the electrostatic material IMPORTANT Replace the filter whenever It has been vacuumed clean 3 times It has been used on a mold remediation job READ AND SAVE THESE INSTRUCTIONS Monthly Remove housing in order to locate the coils catch basin float shaft and drain hose e Check coils and clean when visibly dirty Dirty coils can cause the unit to over heat Unplug unit Remove housing locate coils and allow coils to dry if wet Vacuum both sides of the coils until clean being careful not to let the nozzle touch the fins as that may cause damage by bending them Remove dirt with an aluminum evaporator coil comb available from a refrigeration supply outlet Follow product directions If a sticky oil residue remains on the coils use a squirt bottle to flush the coil using a small amount of detergent e Check catch basin tray and clean when dirt and debris are present 1 wipe clean with a r
3. operate unit when dust or air borne particles are present such as dur ing sanding or spray painting Inspect and clean coils frequently Read and understand manual before use 07 01480C LW 04 13 Copyright 2007 Dri Eaz Products Inc materials especially wood products may crack shrivel or discolor Use of a dehu midifier in high heat conditions will reduce its effeciency and the life of the machine Managing temperature rise Dri Eaz dehumidifiers warm the air as they remove moisture Optimal drying temperatures range from 68 85 F 20 29 C The most accurate way to monitor temperature is with a thermo hygrometer however you can use an indoor outdoor thermometer to gauge temperature just make sure it s located in the center of the room away from the airflow of the dehumidifier Maintain temperatures between 70 90 F 21 32 C to ensure best perform ance and drying results This may require the use of the building s HVAC Heating or Air Conditioning system If there s no HVAC system call a Dri Eaz at 1 888 867 3235 and a Technical Specialist help you find an appropriate solution OPERATING YOUR EVOLUTION LGR DEHUMIDIFIER Setup Place dehumidifier upright If you transport the Evolution LGR in a horizontal position set it upright vertical for at least 30 minutes before you turn it on This is necessary because when the machine is horizontal the oil from the compressor flows into the refrigerant co
4. 35 Check the temperature or sensor cable contact Service for instructions 888 867 3235 Check the touchpad key Press and release each key several times Check for obstructions or kinks in the drain hose 07 01480C LW 04 13 Copyright 2007 Dri Eaz Products Inc PURGE Press the PURGE key to empty water from the pump reservoir During normal operation the pump purges automatically every six minutes or whenever the reservoir is full The display will read PUMP PURGING with a numeral countdown To purge the pump manually 1 Turn the power off using the OFF key and let the unit sit plugged in for about 10 minutes This allows water to drip from the coils 2 Press PURGE to remove residual water Other displays Defrost Cycle During normal operation the temperature sensor detects frost forming on the coils causing a defrost cycle to start The display will read DEFROST ON Dehumidification stops during the defrost cylce When the unit completes the cycle the display will return to DEHUMIFIER ON Messages When the display menu shows the error message GET SERVICE followed by ERO1 or another numeral follow these steps 1 Unplug the unit and then plug it back in This may re set the electronics 2 If that does not fix the problem try the solution if one is listed in the Error Message Table to the left 3 If that does not fix the problem contact the Dri Eaz Service Department at 888 867 3235
5. Compressor will not start Unit needs 5 minutes before restart Switch off unit wait 5 minutes before starting Overload preventing start up Reduce room temperature below 90 F 32 C Blower wheel not turning Obstructed blower Remove obstruction Loose blower wheel set screw Tighten Screw Unit operating but room not dry Not enough time to dry Allow more time for drying Poor air movement in room Increase airmovement with TurboDryers Excessive air infiltration Reduce airflow into the area being dried Unit continuously in defrost Room temperature too low Increase room temperature Unit collects little water Room air is dry Check humidity with hygrometer Room temperature too low Inrease the room temperature Airflow through unit restricted check filter and coils clean if debris Pump does not function Stuck float valve Clean float valve shaft SPECIFICATIONS MODEL EVOLUTION LGR CONTROLS TOUCHPAD F292 nm DEPTH M 70 PINTS DAY 33 LTR HANDLE COLLAPSIBLE METAL 80 F 20 RH 7 PINTS HOUSING ROTOMOLDED OPERATING RANGE 33 90 F 1 32 C POWER 115V 5 6 AMPS COMPRESSOR TYPE 5 595 BTU ROTARY CORD LENGTH 25 FT 7 6 M HOT GAS BYPASS SAFETY MARKS women E 07 01480C LW 04 13 Copyright 2007 Dri Eaz Products Inc
6. DRIEAZ Owner s Manual Evolution LGR Dehumidfier 115v Model DRI EAZ PRODUCTS INC 15180 Josh Wilson Road Burlington WA USA 98233 Fax 360 757 7950 Phone US 360 757 7776 www dri eaz com 07 01480C LW 04 13 Copyright 2007 Dri Eaz Products Inc Owner s Manual Dri Eaz Evolution LGR Dehumidfier 115 volt model READ AND SAVE THESE INSTRUCTIONS Use and Operation A WARNING INTRODUCTION The Evolution LGR dehumidifier reduces humidity in enclosed structural C environments by removing water vapor from the air With proper use the SW W Evolution LGR can help dry wet materials like carpet carpet pad floors walls building contents and more Using dehumidifiers may also prevent secondary damage caused by high humidity FIRE AND ELECTRIC SHOCK HAZARD For best results we recommend you use the Evolution LGR dehumidifer with Dri Eaz TurboDryer airmovers The airmovers speed evaporation by Unit must be electrically grounded lifting moisture into the air eInsert 3 prong plug on power cord directly into matching grounded How THE EvoLuTION LGR Works receptacle Dri Eaz refrigerant dehumidifiers operate by pulling moist air in across a so not use adaptor very cold evaporator core The moisture condenses freezes on the coil Keep wiring and motor dry At intervals the machine will go into defrost mode warming the frost back i to water The water collects in a tray and leaves the unit through a drain Do not o
7. ag e Check drain hose 1 Look for obstructions Disconnect and clear any debris present 2 Reattach gravity drain hose e Inspect filter cover this can be done without removing the housing 1 Vacuum off any visible dirt or wash with mild soap and water 2 Let dry and put back in place a A WN Annually Have the pump system inspected 1 Call a the Dri Eaz Service Department and they ll help locate a Service Center near you 1 888 867 3235 2 To inspect the pump system yourself use the detailed instruction located at www dri eaz com in the Service section Once there click repairs on the left menu and select Trouble shooting a leaky pump Be sure to follow the directions specific to the Evolution If you have questions as you go through the process call a Dri Eaz Service associ ate for assistance at 888 867 3235 3 To access the Evolution LGR pump remove the four bolts located at the bottom of the unit Use a 3 8 nut driver or socket Diagrams 4 amp 6 Diagram 4 Evolution LGR Diagram 6 Diagram 5 Location of blower Pump removal location of 4 bolts 07 01480C LW 04 13 Copyright 2007 Dri Eaz Products Inc TROUBLESHOOTING For any problems not listed below call your local distributor or contact our Service Department toll free at 888 867 3235 PROBLEM CAUSE SOLUTION Unit does not operate No power to machine Plug in the unit check power at outlet Switch not turned on Turn on switch
8. ils reducing the ability of the dehu midifier to function How to unlock the handle On the back of the Evolution LGR just below the top you ll find the handle folded down into the unit Locate the red lever and pull it to the right That releases the handle Flip it up and fold the red lever back into place to lock the handle into position see Diagram 2 Locate drainage system The Evolution LGR pump connects to a plastic drainage hose You ll find the hose on the hose wrap located on the back of the unit see Diagram 1 You can release the hose by flipping the top reel of the hose wrap down simply pull exerting an outward force until you re able to twist it to the right see Diagram 3 Twist it down 180 This feature makes it easy to take off the entire hose quickly Place the unattached hose end in a sink drain bucket even outside anywhere that water can drain out safely If you use a bucket or contained receptacle for water collection check it regularly CAUTION Uncoil and straighten the entire drain hose Do not leave any of portion of the hose coiled on the unit Also check for kinks or obstruction that would restrict the flow of water Failure to do so may cause a water backup in the pump resulting in leakage Plug in electrical cord Locate the electrical cord either on the top or back of the unit The Evolution LGR dehumidifier runs on a 115 volt 15 amp grounded outlet which is stan dard in most homes
9. perate in standing water hose or pump Do not operate in rain or snow IMPORTANT Before moving the unit make sure there s no water in the elf electrical components become pump See how to use the PURGE function under How to Use the Touchpad wet allow them to dry before Controller on page 3 using SETTING UP A DRYING AREA Read and understand manual before use Use in an enclosed space You should operate dehumidifiers in an enclosed area as this creates a drying chamber Close all doors windows or areas that open to the outside to maximize the unit s water removal effeciency Also keep traffic though the drying chamber to a minimum How to position the Evolution LGR dehumidifier e Place your Evolution LGR dehumidifier in the middle of a room away from walls and contents e Keep it away from anything that could prevent airflow into and out of the unit Do not use with an adaptor Use a 115V 3 prong grounded connection Illustration of proper dehumidifier placement 07 01480C LW 04 13 Copyright 2007 Dri Eaz Products Inc READ AND SAVE THESE INSTRUCTIONS CAUTION Do not operate the Evolution LGR dehumidifier at temperatures above 90 F 32 C This can cause damage to both the machine and the structure s contents Over dried Diagram 1 Evolution LGR Diagram 2 Picture of hose release CAUTION Dust can cause unit to overheat and shut down Do not
10. w to change the language display CAUTION While in the change language mode pressing other keys can change the programming of the machine Do NOT press other keys you re not instructed to press Use the DISPLAY key to change the display language Follow these steps 1 Start with the unit unplugged 2 While holding down the DISPLAY key plug the unit in The display reads ENGLISH 3 To change to FRANCAIS DEUTSCH or ESPANOL press the DISPLAY key or the CLEAR key 4 When the desired language is shown in the display unplug the unit and the language is set CLEAR Press the CLEAR key to reset the JOB HOURS 1 As the display cycles between DEHUMIDIFIER ON JOB HOURS OR TOTAL HOURS press the DISPLAY key when JOB HOURS appears on the screen That will make the display read JOB HOURS steadily 2 Then press the CLEAR key to re set the numerals to 00000 3 Press DISPLAY again to re start the display cycle NOTE the TOTAL HOURS reading cannot be re set 07 01480C LW 04 13 Copyright 2007 Dri Eaz Products Inc READ AND SAVE THESE INSTRUCTIONS A WARNING T Electric Shock Hazard Unplug unit before performing any maintenace Never use a water hose or pres sure washer to clean coils water could enter the electrical cam partment causing a shock haz ard Follow cleaning instructions in manual Error Message Table Problem with electronic control panel Contact Dri Eaz Service at 888 867 32

Download Pdf Manuals

image

Related Search

Related Contents

Check list examinateur  IAN 104447 - Lidl Service Website  Continental PS78403 User's Manual  User Manual LCU–ONE Analog  取扱説明書  Equip Cat.5e F/UTP Networking Cable  Icy Dock MB884U-C  Sistema de Informações do Programa Nacional de Imunizações  continui - capas.it  Endos AC/ACP User Manual - at www.ImageWorksCorporation.com.  

Copyright © All rights reserved.
Failed to retrieve file