Home

Leviton VZS15-1L User's Manual

image

Contents

1. date Leviton s only obligation is to correct such defects by repair or replacement at its option if within such five year period the product is returned prepaid with proof of purchase date and a description of the problem to Leviton Manufacturing Co Inc Att Quality Assurance Department 59 25 Little Neck Parkway Little Neck New York 11362 2591 This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation This warranty is void if this product is installed improperly or in an improper environment overloaded misused opened abused or altered in any manner or is not used under normal operating conditions or not in accordance with any labels or instructions There are no other or implied warranties of any kind including merchantability and fitness for a particular purpose but if any implied warranty is required by the applicable jurisdiction the duration of any such implied warranty including merchantability and fitness for a particular purpose is limited to five years Leviton is not liable for incidental indirect special or consequential damages including without limitation damage to or loss of use of any equipment lost sales or profits or delay or failure to perform this warranty obligation The remedies provided herein are the exclusive remedies under this warranty whether based on contract tort or otherwise
2. wall box wire identified tagged when removing old switch to First Traveler note color as above Second Traveler wall box wire note color as above to terminal screw marked YL RD This traveler from the remote must go to the terminal screw on the switch marked YL RD Remove White insulating label from terminal screw marked WH Line Neutral wall box wire to terminal screw marked WH Proceed to Step 5 3 Way Wiring with Matching Remote Testing your Switch prior to mounting in OPERATION For additional information contact Leviton s w LED Application wall box Techline at 1 800 824 3005 or visit Leviton s NOTE The locator light will illuminate when the load is in the OFF position website at www leviton com ae a Matching Remote Switch Serew marked e Position all wires to provide room in t facilitate access in the dark i ne WH outlet wall box for device Push Pad Default settings U S amp Foreign Patents Pending Copyright 2006 Leviton Manufacturing Co Inc All Rights Including Trade Dress Rights Reserved Additional Neutral Wire Ensure that the word TOP is Turn ON from OFF position facing up on device strap Tap Lights turn ON Terminal ee aaa i i Screw marked eg Partially screw in mounting screws Turn OFF from ON position _ Pee ee TOR EONS UNORE FCC COMPLIANCE STATEMENT uoe Minal If there is a power outage when the power is restored the lights will return Yellow R
3. Line YLU RD e Press pad until locator light is OFF Lights 120VAC 60Hz i should turn ON e Consult the dealer or an experienced radio tv technician for help Neutral White NOTE The switch must be installed in a wall box that has a Load 5 N Push Locator connection The matching remote must be installed in a wall box Pad Light with a Line Hot connection and a Neutral connection A Neutral wire to the matching remote needs to be added as shown Cleaning Clean with a damp cloth DO NOT use chemical cleaners If you are unsure about any part of these instructions consult a qualified electrician TROUBLESHOOTIN NOTE Maximum wire length from dimmer to all installed remotes cannot oy gt HOO 2 exceed 300 ft 90 m BJJ Switch Mounting e Lights Flickering WIRING MATCHING REMOTE TURN OFF POWER AT CIRCUIT BREAKER OR FUSE T Lamp has a bad connection l l wall box with Line Hot connection Wires not secured firmly under terminal screws of switch Connect wires per WIRING DIAGRAM as follows and or remote e Green or bare copper wire in wall box to Green terminal screw a Light does not turn ON and Locator LED does not turn ON e Line Hot common wall box wire identified tagged when removing ee old switch and First Traveler to switch terminal screw marked BK p R E Mee A has tripped Second Traveler wall box wire from switch to remote terminal 4 Seige odie A screw marked YL RD note wire colo
4. Terminal Screw marked Black BK Terminal Screw marked _ Yellow Red YL RD Terminal Label Use Terminal for 3 Way or More Applications Only For Single Pole Applications Do Not Remove This Label WARNINGS AND CAUTIONS e Use only one 1 Vizia electronic switch in a multi location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs e Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft 90 m e Disconnect power at circuit breaker or fuse when servicing installing or removing fixture e Use this device only with copper or copper clad wire With aluminum wire use only devices marked CO ALR or CU AL Step 4a cont d Hot Black e Line 120VAC 60Hz Use Terminal for 3 Way or More Applications Only For Single Pole Applications Do Not Remove This Label Neutral White WIRING SWITCH Connect wires per WIRING DIAGRAM as follows e Green or bare copper wire in wall box to Green terminal screw Line Hot wall box wire to terminal screw marked BK Load wall box wire to terminal screw marked RD Line Neutral wall box wire to terminal screw marked WH Switch terminal screw marked YL RD should have Red insulation label affixed NOTE If insulating label is not affixed to terminal screw marked YL RD use electrical tape to cover e Proceed to Step 5 Seely 3 Way Wiring with Coordinating Remote no LED Ap
5. Z LEVITON Building A Connected World DI 000 VZS15 02A X3 WARNINGS AND CAUTIONS e To be installed and or used in accordance with appropriate electrical codes and regulations If you are unsure about any part of these instructions consult a qualified electrician Vizia electronic switches are not compatible with standard 3 way or 4 way switches They must be used with compatible Vizia on off remotes Recommended minimum wall box depth is 2 1 2 Tools needed to install your Switch Slotted Phillips Screwdriver Electrical Tape Pencil Cutters Changing the color of your Switch Your switch includes three color options The switch ships with the White frame attached To change color of frame proceed as follows Pliers Ruler Line up tabs and Push in side press in side to attach at tab to release INSTALLING YOUR SWITCH NOTE Use check boxes V when Steps are completed Step 1 WARNING TO AVOID FIRE SHOCK OR DEATH TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring NOTE If the wiring in your wall box does not resemble any of these configurations consult a qualified electrician Single Pole 1 Line Hot 1 Line or Load see important instruction below 2 Neutral 2 Neutral 3 Ground 3 Ground 4 5 3 Way 4 Load First Traveler note color Second Traveler note color NOTE For matching remote w LEDs installation the First Traveler becomes L
6. ed p L to the last setting before the power interruption This equipment has been tested and found to comply with the limits for URD Toimia N a Class B Digital Device pursuant to Part 15 of the FCC Rules These Screw marked oer limits are designed to provide reasonable protection against harmful ed HD ba J interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment OFF and ON the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving Antenna e Increase the separation between the equipment and the receiver e Connect the equipment into an outlet on a circuit different from that to If lights do not turn ON refer to the which the receiver is connected FA L TROUBLESHOOTING section Matching Remote with LED Switch NOTE Dress wires with a bend as shown in diagram in order to relieve Hot Black WH stress when mounting device aL Groen e Restore power at circuit breaker or fuse
7. ine Hot Single Pole One location or 3 Way Multi location Electronic Switch Cat No VZS15 1L Lighted Incandescent 1800W Magnetic low Voltage 1800VA 1440W Electronic Low Voltage 1800W Fluorescent 1800VA Supplemental 1 2 HP 120VAC 60Hz INSTALLATION INSTRUCTIONS IMPORTANT For 3 Way applications note that one of the screw terminals from the old switch being removed will usually be a different color Black or labeled Common Tag that wire with electrical tape and identify as the common Line or Load in both the switch wall box and remote wall box ESH Preparing and connecting wires This switch can be wired using side wire terminal screws or through backwire openings Choose appropriate wire stripping specifications accordingly 5 8 1 6 cm l A Back Wire either hole may be used Back wire openings use 14 12 AWG solid wire copper only Strip Gage measure bare Cut wire here if necessary l 9 Side Wire Connection Side wire terminals accept 14 AWG solid wire copper only e Make sure that the ends of the wires from the wall box are straight cut if necessary Remove insulation from each wire in the wall box as shown For Single Pole Application go to Step 4a For 3 Way Coordinating Remote no LEDs Application go to Step 4b For 3 Way Matching Remote with LEDs Application go to Step 4c Single Pole Wiring Application L Terminal Screw marked White WH
8. plication Coordinating Remote Terminal Switch Sqperiain Terminal Screw marked Black BK Terminal Screw marked Yellow Red YURD Terminal Screw marked Red RD Step 4b cont d Coordinating Remote no LED Switch 120VAC 60Hz Neutral White WIRING SWITCH Connect wires per WIRING DIAGRAM as follows NOTE The switch must be installed in a wall box that has a Line Hot connection NOTE Maximum wire length from switch to all installed remotes cannot exceed 300 ft 90 m e Green or bare copper wire in wall box to Green terminal screw e Line Hot common wall box wire identified tagged when removing old switch to terminal screw marked BK First Traveler wall box wire to terminal screw marked RD note wire color Remove Red insulating label from terminal screw marked YL RD Second Traveler wall box wire to terminal screw marked YL RD note wire color This traveler from the switch must go to the terminal screw on the remote marked YL RD e Line Neutral wall box wire to terminal screw marked WH WIRING COORDINATING REMOTE Connect wires per WIRING DIAGRAM as follows NOTE BK and RD terminals on coordinating remote are unused Tighten both screws NOTE Maximum wire length from switch to last remote is 300 ft 90 m e Green or bare copper wire in wall box to Green terminal screw e Load
9. r This traveler from the Lamp Neutral connection is not wired remote must go to the terminal screw on the switch marked YL RD hi e Remote does not operate lights Line Neutral wall box wire to remote terminal screw marked WH Installation may now be completed by Ensure that total wire length does not exceed 300 ft 90 m WIRING SWITCH wall box with Load connection tightening mounting screws into wall box Connect wires per WIRING DIAGRAM as follows Attach wallplate e Green or bare copper wire in wall box to Green terminal screw e Load wall box wire identified tagged when removing old switch to terminal screw marked RD Restore Power First Traveler Line Hot to terminal screw marked BK Restore power at circuit breaker or fuse Remove Red insulating label from terminal screw marked YL RD Installation is complete Second Traveler wall box wire note color as above to terminal screw marked YL RD This traveler from the switch must go to the terminal screw on the remote marked YL RD Line Neutral wall box wire to remote terminal screw marked WH Proceed to Step 5 DI 000 VZS15 02A X3 LIMITED 5 YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase

Download Pdf Manuals

image

Related Search

Related Contents

KUDA 097060 holder  e+p T 65 telephony cable  Numark Industries CD MIX-1 User's Manual  Broan ERV90HCS Air Cleaner User Manual  LG Green Rumor User's Manual  Bedienungsanleitung  istruzioni per l`uso e la manutenzione en instruction manual de    . - Callas Software  Lightolier Lytespan Track Lighting System 8276 User's Manual  