Home
KitchenAid 9763382 User's Manual
Contents
1. 20 INSTALLATION INSTRUCTIONS 7 INSTRUCTIONS D INSTALLATION 21 Install Chimney Support T Installation du support de chemin e 21 Complete Chimney Support Installation 8 Achever l installation du support de chemin e 22 Make Electrical Connection 8 Raccordement 22 Install Chimney Covers 9 Installation du cache chemin e 23 Install Range Hood 10 Installation de la hotte de cuisini re 24 Complete Installation 10 Achever l installation 25 Check Operation 11 Contr le du fonctionnement 25 RANGE HOOD USE s s oer rr RR 11 UTILISATION DE LA HOTTE DE CUISINIERE 26 Operation uec et 11 Fonctionnement 26 RANGE HOOD CARE 12 ENTRETIEN DE LA HOTTE DE CUISINIERE 26 Cleaning and Maintenance 12 Nettoyage et entretien 26 ACCESSONES uasa nic eta eae 12 ACGOSSOINCS 27 REQUESTING ASSISTANCE OR SERVICE 13 DEMANDE D ASSISTANCE OU DE S
2. OF ES Sd D Er n Se SSS oe SS 0 0 LA Y A Armature de l extension de chemin e A Vis B Support de chemin e zs C Pid 9 R installer et bien serrer les quatre vis D crou captif 1 Faire passer le c blage travers le trou de 114 3 cm dans le plafond respecter les prescriptions du Code national de l lectricit ou de la norme CSA en vigueur ou des codes et r glements locaux en vigueur Il faut que la longueur des conducteurs soit suffisante pour qu il soit possible de r aliser la liaison entre le tableau de distribution et la hotte et les connexions dans la boite de connexion de la hotte 2 Utiliser un calfeutrant pour assurer l tanch it au niveau de Risque de choc lectrique chaque ouverture NOTE Ne pas reconnecter la source de courant lectrique avant d avoir compl tement termin l installation 3 Enlever le couvercle du bo tier de connexion sur la section D connecter la source de courant lectrique avant l entretien Replacer pieces et panneaux avant de faire la remise sup rieure du support de chemin e en marche 4 Installer un serre c ble homologation UL ou CSA sur le Le non respect de ces instructions peut causer boitier de connexion veiller ce qu il soit possible de serrer un d c s ou un choc lec
3. and 9 194 2 79 m For recirculating installations the chimney can be adjusted for ceilings between 8 3 2 52 m and 9 5 74 2 88 m M Vent system must terminate to the outside except for the recirculating installation E Do not terminate the vent system in an attic or other enclosed area Bi Do not use 4 10 2 cm laundry type wall caps Use 6 15 2 cm metal vent only Rigid metal vent is recommended Do not use plastic or metal foil vent For the most efficient and quiet operation Use a straight run or as few elbows as possible Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than one elbow is used Wi Do not install two elbows together Use duct tape to seal all joints in the vent system Use caulking to seal exterior wall or roof opening around the cap Cold weather installations An additional backdraft damper should be installed to minimize backward cold air flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the vent system The damper should be on the cold air side of the thermal break The break should be as close as possible to where the vent System enters the heated portion of the house Make up air Local building codes may require the use of make up air systems when using ventilation systems greater than specified CFM of air movement The specified CFM var
4. 3 Remove wiring box cover located on the top section of the Fiectmical Shock Hazard chimney support Electrically ground blower 4 Install a UL or CSA listed strain relief in the wiring box so that Connect ground wire to green ground screw in the screws can be tightened after the chimney support is terminal box attached to the ceiling 5 Lift chimney support into final position feeding electrical wire through the strain relief Failure to do so can result in death or electrical shock 6 Position the chimney support so that the large end of the 4 Connect ground wire to green ground screw in terminal box keyhole slots are over the ceiling attachment bolts Then push the chimney support so that the bolts are in the neck of the A slots Tighten bolts securely IMPORTANT The chimney support must be securely attached to the ceiling 7 Determine the desired length of the chimney support 8 Remove the four screws and adjust the length of the lower chimney support as needed NOTE This is the only section that can be adjusted A Ground screw connector B Ground wire Ss C Power supply cable 5 Tighten strain relief securely 6 Replace wiring box cover Tighten screw securely V E A Screws Vented Installation Option 1 Attach the vent system to the damper Seal all joints with duct tape 2 Remove the plastic
5. Chimney Extension Kit Installation Optional 1 Remove the plastic covering from the chimney covers 2 Discard the upper chimney cover supplied with the hood 3 Slide the chimney cover provided with the extension kit over the lower chimney support and extension frame and secure to the top of the extension frame using the two screws provided A B gt C NN A Screw B Upper chimney extension cover C Lower chimney cover 4 Slide lower chimney cover over the chimney support and extension chimney cover and attach to the bottom of the support using the two screws provided A Chimney extension kit assembled to hood assembly with chimney covers attached 1 Lift the hood up against the chimney support and attach to the support with 4 bolts provided Tighten bolts securely 10 2 From the underside of the hood plug control cables together as shown Insert each connected cable into a black plastic connector box half 4 Place the top half of the connector box on each and screw the two halves together using the four screws provided for each connector box A Screws B Connector box half 5 Using the two longer screws provided for each box attach the assembled connector boxes to the metal flange 1 recirculating installations only install charcoal filter from Recirculating Chimney Kit behind the center grease filter by inserting and locking
6. product warranty and provide after warranty service anywhere in the United States To locate the designated service company in your area you can also look in your telephone directory Yellow Pages If you need replacement parts If you need to order replacement parts we recommend that you use only factory authorized parts These parts will fit right and work right because they are made to the same exacting specifi cations used to build every new KitchenAid appliance To locate factory authorized parts in your area call our Customer Interaction Center telephone number your nearest authorized service center or 1 800 442 1111 For further assistance If you need further assistance you can write to KitchenAid with any questions or concerns at Customer Interaction Center c o Correspondence Dept 2000 North M 63 Benton Harbor 49022 2692 Please include a daytime phone number in your correspondence If you need assistance or service in Canada For product related questions please call the KitchenAid Canada Inc Customer Interaction Center toll free 1 800 461 5681 Monday to Friday 8 00 a m 6 00 p m EST Saturday 8 30 a m 4 30 p m EST Our consultants provide assistance with M Features and specifications on our full line of appliances Referrals to local dealers For parts accessories and service in Canada Call 1 800 807 6777 KitchenAid Canada Inc designated service technicians are trained to fulfill
7. 28 Si vous avez besoin d assistance ou de service au Canada Pour des questions relatives aux produits veuillez appeler sans frais le Centre d interaction avec la client le de KitchenAid Canada Inc au 1 800 461 5681 Du lundi au vendredi de 8 h 00 18 h 00 HNE Le samedi de 8 h 30 16 h 30 HNE Nos consultants fournissent de l assistance pour Caract ristiques et sp cifications de notre gamme compl te d appareils m nagers R f rences aux concessionnaires locaux Pour pi ces accessoires et service au Canada T l phoner au 1 800 807 6777 Les techniciens de service d sign s par KitchenAid Canada Inc sont form s pour remplir la garantie des produits et fournir un service apr s garantie partout au Canada Pour plus d assistance Si vous avez besoin de plus d assistance vous pouvez crire KitchenAid Canada Inc en soumettant toute question ou probl me au Centre d interaction avec la client le KitchenAid Canada Inc 1901 Minnesota Court Mississauga Ontario L5N 3A7 Dans votre correspondance veuillez indiquer un num ro de t l phone l on peut vous joindre dans la journ e GARANTIE DU SYST ME DE VENTILATION KITCHENAID GARANTIE LIMIT E DE UN AN Pendant un an compter de la date d achat lorsque ce gros appareil m nager est utilis et entretenu conform ment aux instructions jointes ou fournies avec le produit KitchenAid ou KitchenAid Canada ci apr s d sign es Kit
8. avant d entreprendre une cuisson et laisser le ventilateur fonctionner pendant plusieurs minutes apr s l ach vement d une cuisson pour pouvoir vacuer de la cuisine toute trace d odeur de cuisson vapeur ou fum e Tableau de commande de la hotte Les commandes de la hotte sont situ es sur la droite du panneau de fa ade de la hotte t moin de fonctionnement du ventilateur Commutateur d clairage 1 Appuyer sur le bouton de droite pour commander l allumage des lampes 2 Appuyer de nouveau sur ce bouton pour commander l extinction Utilisation du ventilateur 1 Appuyer sur le bouton de gauche 1 pour commander mise en marche du ventilateur NOTE Quelle que soit la vitesse s lectionn e pour le ventilateur il faut que ce bouton soit enfonc pour que le ventilateur fonctionne Le t moin de fonctionnement du ventilateur s illumine alors et le ventilateur fonctionne basse vitesse 2 Appuyer sur le bouton 2 pour s lectionner la vitesse moyenne 3 Appuyer sur le bouton 3 pour s lectionner la haute vitesse 4 Appuyer sur le bouton 1 pour commander l arr t du ventilateur 26 Avant toute op ration de nettoyage de la hotte v rifier que les lampes ont refroidi Surfaces externes Bi Ne pas utiliser de tampon de laine d acier ou un tampon de r curage savonneux M Frotter dans la direction des lignes du grain pour ne pas d t riorer la surface M S cher
9. d utilisation et d entretien Apr s avoir v rifi la section D pannage de l aide suppl mentaire peut tre trouv e en v rifiant la section Assistance ou service ou en appelant KitchenAid Aux E U composer le 1 800 422 1230 Au Canada composer le 1 800 807 6777 10 05 Conservez ce manuel et votre recu de vente ensemble pour Nom du marchand r f rence ult rieure Pour le service sous garantie vous devez pr senter un document prouvant la date d achat ou Adresse d installation Num ro de t l phone Inscrivez les renseignements suivants au sujet de votre appareil m nager pour mieux vous aider obtenir assistance ou service Num ro de mod le en cas de besoin Vous devrez conna tre le num ro de mod le et le num ro de s rie au complet Vous pouvez trouver cette Num ro de s rie information sur la plaque signal tique situ e sur votre appareil Date d achat 29 A SCHEMA DE CABLAGE 3HOL V Hf3lvINHOJSNVH L 3dAV 1 4 eas INN ANM iv LA Jamiy jani 4 GROUPE MOTEUR i N IL i 2 i oo gt gt oo gt gt gt PEN gt i TNO lt a des atu Big 5 wo uo N EZ 1 1 NOIX3NNOO 30 NOTES 31 9763382 Printed in Italy 2005 KitchenAid Imprim en Ita
10. le permettent et si on utilise un conducteur distinct de liaison la terre il est recommand qu un lectricien qualifi v rifie la qualit de la liaison la terre Pour obtenir un exemplaire des codes mentionn s ci dessus contacter National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 L appareil doit tre aliment par un circuit de 120 V 60 Hz CA seulement 15 amp res prot g par fusible On recommande galement d utiliser un fusible ou un disjoncteur temporis est recommand d alimenter la hotte par un circuit distinct qui n alimente que cet appareil Ne pas utiliser une tuyauterie de gaz pour le raccordement la terre En cas de doute quant la qualit de la liaison la terre de la hotte consulter un lectricien qualifi Ne pas installer un fusible dans le conducteur neutre ou dans le conducteur de liaison la terre La hotte doit tre raccord e au r seau lectrique uniquement avec des conducteurs de cuivre La hotte doit tre raccord e directement au coupe circuit avec fusible ou au disjoncteur par l interm diaire d un c ble conducteurs de cuivre blindage m tallique flexible ou gaine non m tallique Un serre c ble homologation UL ou CSA doit tre install chaque extr mit du c ble d alimentation Le calibre des conducteurs cuivre s
11. par essuyage pour viter de laisser des marques d eau Pour le nettoyage des surfaces d acier inoxydable de ce produit on recommande l emploi du produit de nettoyage et poli pour acier inoxydable KitchenAid Professional Formula On peut commander ce produit aupr s du Centre de service la client le au 1 800 442 9991 ou en ligne www applianceaccessories com commander la pi ce n 8171420 Pour commander au Canada t l phoner au 1 800 807 6777 W Dans le cas de l utilisation d un produit de nettoyage commercial appliquer les instructions fournies avec le produit Ne pas utiliser un produit qui pourrait contenir du chlore agent corrosif Pour le nettoyage de routine et l limination des marques de doigt utiliser de l eau et un savon d tergent liquide Essuyer avec une ponge ou un chiffon humide puis rincer avec de l eau propre et s cher par essuyage Filtres m talliques Il convient de nettoyer fr quemment les filtres Nettoyer les filtres au lave vaisselle ou avec une solution de d tergent chaude D pose des filtres m talliques NOTE Utiliser les deux mains pour d poser les filtres avec une main tirer et faire tourner le bouton avec l autre main tenir le filtre pour qu il ne tombe pas sur la table de cuisson 1 Tirer le bouton vers l avant de la hotte tout en faisant tourner le bouton vers la gauche sens anti horaire pour lib rer la tige de blocage 2 Faire glisser le filtre vers le bas
12. the product warranty and provide after warranty service anywhere in Canada For further assistance If you need further assistance you can write to KitchenAid Canada Inc with any questions or concerns at Customer Interaction Center KitchenAid Canada Inc 1901 Minnesota Court Mississauga Ontario L5N 3A7 Please include a daytime phone number in your correspondence 13 KITCHENAID VENTILATION WARRANTY ONE YEAR LIMITED WARRANTY For one year from the date of purchase when this major appliance is operated and maintained according to instructions attached to or furnished with the product KitchenAid or KitchenAid Canada hereafter KitchenAid will pay for factory specified parts and repair labor to correct defects in materials or workmanship Service must be provided by a KitchenAid designated service company ITEMS KITCHENAID WILL NOT PAY FOR 1 Service calls to correct the installation of your major appliance to instruct you how to use your major appliance to replace or repair house fuses or to correct house wiring or plumbing 2 Service calls to repair or replace appliance light bulbs air filters or water filters Those consumable parts are excluded from warranty coverage 3 Repairs when your major appliance is used for other than normal single family household use Damage resulting from accident alteration misuse abuse fire flood acts of God improper installation installation not in accordance with electrica
13. the right hand button L in to turn the lights on 2 Push in again to turn lights off Operating the blower 1 Push the left hand button 1 in to turn the blower on NOTE This button must be pushed in for the blower to operate at any speed The blower indicator light will light up to indicate blower is on and the blower will operate at low speed 2 Push button 2 to operate the blower at medium speed Push button 3 to operate blower at high speed 4 Push button 1 to turn blower off e 11 RANGE HOOD CARE Be sure lights are cool before cleaning the hood Exterior surfaces W Do not use steel wool or soap filled scouring pads Rub in direction of the grain line to avoid marring the surface Always wipe dry to avoid water marks KitchenAid Professional Formula Stainless Steel Cleaner amp Polish is the cleaner recommended for cleaning stainless steel surfaces on this product To order call our Customer Service Center at 1 800 442 9991 or order on line at www applianceaccessories com and ask for part number 8171420 To order from Canada call 1 800 807 6777 W f commercial cleaners are used follow label directions Do not use products that contain chlorine bleach Chlorine is a corrosive substance For routine cleaning and fingerprints use liquid detergent soap and water Wipe with damp cloth or sponge then rinse with clean water and wipe dry Metal filters The filters should be washed fr
14. verrouiller le tableau de disjoncteurs placer sur le tableau de disjoncteurs une tiquette d avertissement pro minente interdisant le r tablissement de l alimentation m Tout travail d installation ou c blage lectrique doit tre r alis par une personne qualifi e dans le respect des prescriptions de tous les codes et normes applicables y compris les codes du b timent et de protection contre les incendies m Une source d air de d bit suffisant est n cessaire pour le fonctionnement correct de tout appareil gaz combustion et vacuation des gaz combustion par la chemin e pour qu il n y ait pas de reflux des gaz de combustion Respecter les directives du fabricant de l quipement de chauffage et les prescriptions des normes de s curit comme celles publi es par la National Fire Protection Association NFPA et l American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE et les prescriptions des autorit s r glementaires locales Lors d op rations de d coupage et de percage dans un mur ou un plafond veiller ne pas endommager les c blages lectriques ou canalisations qui peuvent s y trouver Les syst mes d vacuation doivent toujours d charger l air l ext rieur MISE EN GARDE Cet appareil est congu uniquement pour la ventilation g n rale Ne pas l utiliser pour l extraction de mati res ou vapeurs dangereuses ou explosives MISE EN GARDE Pour minimiser le risq
15. ERVICE 28 RANGE HOOD WARRANTY 14 GARANTIE DE LA HOTTE DE CUISINIERE 29 WIRING DIAGRAM 15 SCHEMA DE C BLAGE 30 RANGE HOOD SAFETY Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all safety messages This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean DANGER AWARNING All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed You can be killed or seriously injured if you don t immediately follow instructions You can be killed or seriously injured if you don t follow instructions IMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING m Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer Before servicing or cleaning the unit switch the power off at the service panel disconnecting means to prevent power from being switched on accidentally When the service disco
16. KitchenAid 36 91 4 cm PRO LINE SERIES ISLAND RANGE HOOD HOTTE D ASPIRATION PRO LINE DE 36 91 4 cm POUR CUISINE CONFIGUREE EN ILOT Table of Contents Table des mati res IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY IMPORTANT LIRE ET CONSERVER CES INSTRUCTIONS POUR UTILISATION RESIDENTIELLE UNIQUEMENT IMPORTANT Installer Leave installation instructions with the homeowner Homeowner Keep installation instructions for future reference Save installation instructions for local inspector s use IMPORTANT Installateur Remettre les instructions d installation au propri taire Propri taire Conserver les instructions d installation pour consultation ult rieure Conserver les instructions d installation pour consultation par l inspecteur local 9763382 TABLE OF CONTENTS TABLE DES MATIERES RANGE HOOD SAFETY 2 SECURITE DE LA HOTTE DE CUISINIERE 16 INSTALLATION REQUIREMENTS 4 EXIGENCES D INSTALLATION 18 Tools and Parts 4 Outillage et pi ces 18 Location Requirements 4 Exigences d emplacement 18 Venting Requirements 5 Exigences concernant l vacuation 19 Electrical Requirements 6 Sp cifications lectriques
17. chenAid paiera pour les pi ces sp cifi es par l usine et la main d uvre pour corriger les vices de mat riaux ou de fabrication Le service doit tre fourni par une compagnie de service d sign e par KitchenAid KITCHENAID NE PRENDRA PAS EN CHARGE 1 Les visites de service pour rectifier l installation du gros appareil m nager montrer l utilisateur comment utiliser l appareil remplacer ou r parer des fusibles ou rectifier le c blage ou la plomberie du domicile 2 Les visites de service pour r parer ou remplacer les ampoules lectriques de l appareil les filtres air ou les filtres eau Ces pi ces consomptibles ne sont pas couvertes par la garantie 3 Les r parations lorsque le gros appareil m nager est utilis des fins autres que l usage unifamilial normal 4 Les dommages imputables accident modification usage impropre ou abusif incendie inondation actes de Dieu installation fautive ou installation non conforme aux codes d lectricit ou de plomberie ou l utilisation de produits non approuv s par KitchenAid 5 Le co t des pi ces de rechange et de la main d uvre pour les appareils utilis s hors des tats Unis ou du Canada 6 Leramassage et la livraison Ce gros appareil m nager est concu pour tre r par domicile 7 Les r parations aux pi ces ou syst mes r sultant d une modification non autoris e faite l appareil 8 Les frais de voyage ou de transport pour le service d un pro
18. covering from the chimney covers 3 Slide the upper chimney cover over the chimney support and attach to the top of the support using two screws provided lt lt A Upper chimney cover B Lower chimney cover C Screw 4 Slide the lower chimney cover over the chimney support and the upper cover Attach to the bottom of the support using two screws provided Recirculating Installation Option Kit Required 1 Remove the plastic covering from the chimney covers 2 Slide the upper chimney cover over the chimney support and attach to the top of the support using two screws provided 3 Place the diverter from the Recirculating Chimney Kit over the vent motor exhaust outlet and push down to seat on the outlet Make sure the diverter exhaust outlets are parallel with the vent motor sides so that they will align with the vent cover openings in lower chimney A A Diverter B Vent motor 4 Install the two vent extension pieces onto the diverter pushing them until they stop A Vent extensions 5 Discard the lower chimney cover shipped with the hood and use the cover from the Recirculating Kit purchased separately 6 Slide the recirculating kit lower chimney cover over the chimney support and the upper cover Make sure the diverter extensions line up with the openings in the cover Attach the cover using the two screws provided 7 Snap vent grilles into place A Vent grill location
19. culating installations see Recirculating Installations in Install Chimney Covers section All openings in ceiling and where island hood will be installed must be sealed Product Dimensions 1394 12146 34 9 30 6 2638 65 1 min 39 99 1cm max 27 d d 69 9 DX 35 89 9 cm 12 1 Recirculating chimney kit dimensions For recirculating installations optional Recirculating Chimney Kit No 4396911 Stainless Steel or Kit No 4396912 Meteorite must be used These kits include a new lower chimney cover that replaces the lower chimney cover shipped with the island hood a charcoal filter and a diverter 1334 12 746 32 81 3 39 99 1 Installation Clearances see NOTE 36 91 4 cm typical countertop height NOTE The hood chimneys are adjustable and designed to meet varying ceiling or soffit heights depending on the distance X between the bottom of the hood and the cooking surface For higher ceilings a 40 101 6 cm Chimney Extension Kit No 4396913 Stainless Steel or Kit No 4396914 Meteorite is available See your dealer The chimney extension replaces the upper chimney shipped with the hood IMPORTANT Minimum distance X 24 61 0 cm Suggested maximum distance X 30 76 2 cm For vented installations the chimneys can be adjusted for ceilings between 7 7 2 31
20. duit dans les r gions loign es 9 La d pose et la r installation de votre appareil si celui ci est install dans un endroit inaccessible ou n est pas install conform ment aux instructions d installation fournies CLAUSE D EXON RATION DE RESPONSABILIT AU TITRE DES GARANTIES IMPLICITES LIMITATION DES RECOURS LE SEUL ET EXCLUSIF RECOURS DU CLIENT DANS LE CADRE DE LA PR SENTE GARANTIE LIMIT E CONSISTE EN LA R PARATION PR VUE CI DESSUS LES GARANTIES IMPLICITES Y COMPRIS LES GARANTIES APPLICABLES DE QUALIT MARCHANDE ET D APTITUDE UN USAGE PARTICULIER SONT LIMIT ES UN AN OU ALA PLUS COURTE P RIODE AUTORIS E PAR LA LOI KITCHENAID N ASSUME AUCUNE RESPONSABILIT POUR LES DOMMAGES FORTUITS OU INDIRECTS CERTAINES JURIDICTIONS NE PERMETTENT PAS L EXCLUSION OU LA LIMITATION DES DOMMAGES FORTUITS OU INDIRECTS OU LES LIMITATIONS DE LA DUR E DES GARANTIES IMPLICITES DE QUALIT MARCHANDE OU D APTITUDE UN USAGE PARTICULIER DE SORTE QUE CES EXCLUSIONS OU LIMITATIONS PEUVENT NE PAS S APPLIQUER DANS VOTRE CAS CETTE GARANTIE VOUS CONFERE DES DROITS JURIDIQUES SPECIFIQUES ET VOUS POUVEZ EGALEMENT JOUIR D AUTRES DROITS QUI PEUVENT VARIER D UNE JURIDICTION A UNE AUTRE l ext rieur du Canada et des 50 tats des tats Unis cette garantie ne s applique pas Contacter votre marchand KitchenAid autoris pour d terminer si une autre garantie s applique Si vous avez besoin de service voir d abord la section D pannage du Guide
21. e est variable d une juridiction une autre Pour d terminer les exigences sp cifiques consulter un professionnel local des installations de chauffage et climatisation M thodes d vacuation Cette hotte d extraction a t configur e l usine pour la d charge travers le toit ou le mur Pour l installation un circuit d vacuation constitu de conduits ronds de diam tre 6 15 2 cm non fourni est n cessaire L orifice de sortie de la hotte est circulaire diam 6 15 2 cm NOTE On d conseille l emploi de conduit flexible Un conduit flexible peut susciter une r tro pression et des turbulences de l air ce qui r duit consid rablement la performance La d charge de l air aspir peut tre effectu e travers le mur ou le toit Pour la d charge travers le mur on doit utiliser un raccord coud 90 La longueur effective d un circuit d vacuation en conduit rond de 6 15 2 cm ne doit pas d passer 35 pi 10 7 m Pour une installation avec recyclage voir Installation avec recyclage la section Installation du circuit d vacuation mitre conduit conduit rond rond bouche de dia 6 dia 6 ascharge 15 2 cm murale 15 2 cm d charge travers le toit d charge travers le mur 19 Calcul de longueur effective du circuit d vacuation Pour calculer la longueur effective du circuit d vacuation n cessaire ajouter les l
22. e lampes halog ne 12 V 20 W teindre la hotte de cuisini re et laisser les lampes halog ne refroidir Remplacer l ampoule en utilisant un chiffon ou en portant des gants en coton Ne pas manipuler l ampoule mains nues 1 D connecter la source de courant lectrique 2 Oter les deux vis de fixation de la garniture circulaire autour de la lampe 3 Tirer vers le bas la garniture avec la lampe encore attach e suffisamment pour qu il soit possible de d gager la lampe des agrafes de la douille 4 Ins rer une lampe neuve et remettre en place dans la hotte la lampe et sa garniture 5 R installer les vis de fixation 6 Reconnecter la source de courant lectrique Filtre charbon de rechange Pi ce n 8285507 27 DEMANDE D ASSISTANCE OU DE SERVICE Si vous avez besoin d assistance ou de service aux Etats Unis T l phoner au Centre d interaction avec la clientele KitchenAid sans frais au 1 800 253 1301 Nos consultants sont disponibles pour vous aider Lors de votre appel Veuillez conna tre la date d achat et les num ros de mod le et de s rie au complet de votre appareil Ces renseignements nous aideront mieux r pondre votre demande Nos consultants fournissent de l assistance pour m Caract ristiques et sp cifications de notre gamme d appareils m nagers m Renseignements d installation m Proc d s d utilisation et d entretien m Ve
23. en fonction de la hauteur disponible sous plafond ou soffite et selon la distance entre le bas de la hotte et le plan de travail Pour une hauteur sous plafond plus lev e des sections d extension de chemin e de 40 10 2 cm sont disponibles kit n 4396913 acier inoxydable ou kit 4396914 m t orite consulter le revendeur ce sujet L extension de chemin e remplace la section de chemin e sup rieure fournie avec la hotte IMPORTANT Valeur minimale de la distance X 24 61 cm Valeur maximale sugg r e pour la distance X 30 76 2 cm Pour une installation avec d charge l ext rieur on peut ajuster la chemin e pour une hauteur sous plafond de 7 78 2 31 m 9 194 2 79 m Pour une installation avec recyclage on peut ajuster la chemin e pour une hauteur sous plafond de 8 336 2 52 m 9 5 2 88 m Le circuit d vacuation de l air doit se terminer l ext rieur sauf pour une installation avec recyclage Ne pas terminer le circuit d vacuation dans un espace ferm grenier ou autre Ne pas utiliser une bouche de d charge murale de 4 10 2 cm du type utilis pour un appareil de buanderie B Utiliser uniquement un conduit m tallique de 6 15 2 cm On recommande l emploi de conduit rigide Ne pas utiliser de conduit de plastique ou de m tal tr s mince Pour obtenir un fonctionnement efficace et silencieux Wi Utiliser autant que possible des
24. en le faisant sortir de la rainure de retenue avant R installation des filtres m talliques NOTE Utiliser les deux mains pour r installer les filtres avec une main tirer et faire tourner le bouton avec l autre main maintenir le filtre pour qu il ne tombe pas sur la table de cuisson 3 R installation des filtres graisse tirer d abord et faire tourner le bouton vers la gauche pour que la tige de verrouillage ne d passe pas du filtre 4 Ins rer l extr mit oppos e du filtre dans la rainure de retenue 5 Ins rer l extr mit se trouve le bouton et faire tourner le bouton vers la droite pour caler le filtre en place 6 R p ter ces op rations pour les autres filtres Filtres charbon Installation sans d charge l ext rieur recyclage Les filtres charbon ne sont pas lavables ou r utilisables On doit changer les filtres charbon intervalle de quatre mois utilisation normale ou plus fr quemment si n cessaire Les filtres charbon retiennent les compos s responsables des odeurs de cuisson Remplacement des filtres charbon 1 Enlever les filtres graisse m talliques voir ci dessus Filtres m talliques 2 Faire tourner les deux agrafes m talliques vers le filtre pour lib rer le filtre charbon Enlever le vieux filtre 3 R installer le filtre graisse m tallique Remplacement d une lampe halog ne L clairage sous la hotte est assur par quatr
25. equently Place metal filters in dishwasher or hot detergent solution to clean To remove metal filters NOTE Use two hands to remove filters one to pull and turn the knob the other to hold the filter so that it doesn t fall onto the cooktop 1 Pull knob forward toward the front of the hood while turning the knob to the left counter clockwise to release the locking lever 2 Slide filter down and away from front retaining channel To replace metal filters NOTE Use two hands to replace filters one to pull and turn the knob the other to hold the filter so that it doesn t fall onto the cooktop 3 Replace metal filters by first pulling and turning the knob to the left so that the locking lever does not protrude from the filter 4 Insert the opposite end of the filter into the retaining channel 5 Insert knob end and turn knob to the right to lock the filter into place 6 Repeat for remaining filters Charcoal Filters For recirculating installations The charcoal filters are not washable nor reusable They should be changed every 4 months in normal use or more often if needed The charcoal filters capture unpleasant cooking odors To replace charcoal filters 1 Remove the metal grease filters see Metal filters above 2 Rotate the two metal filter clips toward the filter to release the charcoal filter Remove old filter 3 Reinstall metal grease filter 12 Replacing a halogen lamp This hood use
26. er une surface plane pour l assemblage de la hotte Lors de l assemblage recouvrir cette surface avec un mat riau de protection couverture ou feuille de carton NOTE Ne pas d j enlever la feuille de plastique destin e recouvrir le cache chemin e durant l installation Faire intervenir deux personnes ou plus pour placer sur cette surface tous les composants et accessoires de la hotte La chemin e de la hotte est exp di e assembl e on doit la d monter pour l installation 3 4 S parer les parties du cache chemin e S parer la section inf rieure du cache chemin e du support de chemin e enlever les deux vis Phillips en bas l ext rieur du cache chemin e S parer la section sup rieure du cache chemin e du support de chemin e enlever les deux vis Phillips au sommet l ext rieur du cache chemin e Marquer l axe central de la hotte et de la table de cuisson sur le plafond en veillant ce que la hotte soit centr e au dessus de la surface de cuisson 10 11 12 13 1 Avec du ruban adh sif fixer le gabarit fourni dans l emballage du support de chemin e au plafond et marquer la position des trous de montage du trou de passage du c ble lectrique et du conduit d vacuation le cas ch ant A Gabarit coll au plafond B Axe central C Table de cuisson Selon la m thode de fixation employ e percer les avant trous appropri s travers les trous de montage d
27. eulement et les connexions doivent tre compatibles avec la demande de courant de l appareil sp cifi e sur la plaque signal tique B La taille des conducteurs doit satisfaire aux prescriptions de la plus r cente dition du National Electrical Code ANSI NFPA 70 ou du Code canadien des installations lectriques normes CSA C22 1 94 et C22 2 n 0 91 et aux prescriptions de tous les codes et r glements locaux en vigueur INSTRUCTIONS D INSTALLATION Du fait du poids et de la taille de cette hotte d extraction pour ilot il faut que le support de chemin e soit solidement fix au plafond 2 Pour un plafond en platre ou en panneaux de gypse le support de chemin e doit tre fix aux solives si ceci n est pas possible on doit construire une structure de support appropri e derri re le plafond en pl tre ou panneaux de gypse On ne doit couper un poteau de colombage ou une solive que si c est absolument n cessaire S il est n cessaire de couper un poteau ou une solive on devra construire une structure de support appropri e Avant d ex cuter les d coupages v rifier la disponibilit d un espace de passage suffisant dans le plafond ou le mur pour le conduit d vacuation A AVERTISSEMENT Risque du poids excessif Utiliser deux ou plus de personnes pour d placer et installer la hotte de la cuisini re Le non respect de cette instruction peut causer une blessure au dos ou d autre blessure S lectionn
28. he chimney during installation 2 Using two or more people place all hood parts and hardware on the protective covering The chimney section of the hood is shipped assembled It must be disassembled for installation 3 Slide apart the chimney covers 4 Remove the lower chimney cover from the chimney support by removing the two Phillips screws on the outside bottom of the chimney cover 5 Remove the upper chimney cover from the chimney support by removing the two Phillips screws on the outside top of the chimney cover 6 Determine and mark the centerline on the ceiling where the hood will be installed making sure that the hood is centered over the cooking surface 7 Tape the template supplied in the chimney support carton to the ceiling and mark the mounting holes electrical hole and vent location if used on the ceiling A Template on ceiling B Centerline C Cooking surface 8 Drill pilot holes in the chimney support mounting hole locations for your attachment method 9 Use a 1 or 3 0 cm drill bit to drill the hole for the power supply cable 10 If venting to the outside cut the hole for the vent system in the ceiling and install the vent system See Venting Requirements section 11 If venting to the outside place the round damper into the exhaust opening of the vent motor housing 12 Remove the 4 chimney support ceiling attachment bolts from the parts bag and install in previously drilled pilo
29. here Tools needed m level m drill with 1 3 0 cm drill bit m pilot hole drill bit determined by chimney support attachment method m pencil m wire stripper or utility knife m measuring tape or ruler m pliers m caulking gun and weatherproof caulking compound m duct tape jig saw or keyhole saw m flat blade screwdriver m metal snips m Phillips screwdriver Parts needed m 2 UL or CSA listed 12 12 5 mm strain reliefs power supply cable 1 wall or roof cap metal vent system 4 concrete anchors for x 4 hex head lag bolts if installing into concrete Parts supplied Remove parts from packages Check that all parts were included hood canopy assembly with ventilator and light bulbs installed chimney assembly ceiling template Installation Instructions and Use amp Care Guide 3 filters hardware package 4 wood shelf bolts 4 wood shelf bolt washers 4 wood shelf nuts 4 concrete plugs 1 mounting template 1 damper IMPORTANT Observe all governing codes and ordinances Island hood location should be away from strong draft areas such as windows doors and strong heating vents Cabinet opening dimensions that are shown must be used Given dimensions provide minimum clearance Grounded electrical outlet is required See Electrical Requirements section It is recommended that the hood be fastened into solid wood The island hood is factory set for venting through the roof or wall For recir
30. hode de fixation du support de chemin e crayon pince d nuder ou couteau utilitaire m tre ruban ou r gle pince pistolet de calfeutrage et compos de calfeutrage r sistant l eau ruban adh sif pour conduits scie sauteuse ou scie guichet tournevis lame plate cisailles de ferblantier tournevis Phillips Pi ces n cessaires 2 serre c bles 2 12 5 mm homologation UL ou CSA m c ble d alimentation lectrique 1 bouche de d charge d charge travers le mur ou travers le toit W circuit d vacuation m tallique 4 vis d ancrage pour b ton 74 x 4 t te hexagonale en cas de fixation sur du b ton Pi ces fournies Retirer les pi ces des emballages V rifier la pr sence de toutes les pi ces m hotte d extraction avec ventilateur et lampe install s chemin e gabarit pour plafond Instructions d installation et Guide d utilisation et d entretien 3 filtres un paquet de pi ces de quincaillerie 4 vis pour tablette en bois 4 rondelles pour vis pour tablette en bois 4 crous pour tablette en bois 4 bouchons en b ton 1 gabarit de montage 1 clapet IMPORTANT Observer les dispositions de tous les codes et r glements en vigueur Installer la hotte d extraction distance de toute zone expos e des courants d air comme fen tres portes et bouches de chauffage Respecter les dimensions indiqu es pour les ouvertures d couper dans les placards Les dimension
31. ies from locale to locale Consult your HVAC professional for specific requirements in your area Venting Methods This hood is factory set for venting through the roof or wall A 6 15 2 cm round vent system is needed for installation not included The hood exhaust opening is 6 15 2 cm round NOTE Flexible vent is not recommended Flexible vent creates back pressure and air turbulence that greatly reduces performance Vent system can terminate either through the roof or wall To vent through a wall a 90 elbow is needed A 6 15 2 cm round vent system length should not exceed 35 feet 10 7 m For recirculating installations see Recirculating Installations in Install Chimney Covers section roof cap 6 15 2 round vent wall 15 2 cm cap round vent Roof venting Wall venting Calculating Vent System Length To calculate the length of the system you need add the equivalent feet meters for each vent piece used in the system Maximum equivalent vent length is 35 feet 10 7 meters Vent piece 6 15 2 cm round 45 elbow 2 5 feet 0 8 m 9 90 elbow 5 0 feet 1 5 m S wall cap 90 elbow ft 1 8 m gt Example vent system 2ft 1 90 elbow 5ft 1 5 m Mem 8 ft 2 4 m straight 8ft 24m y 1 wall cap oft system length 138 3 9 NOTE Flexible vent is not recommended Flexible ve
32. it in place eA 2 Install grease filters using two hands by first pulling and turning the knob to the left so that the locking lever does not protrude from the filter 3 Insert the opposite end of the filter into the retaining channel 4 Insert knob end and turn knob to the right to lock the filter into place A Locking lever slot B Retaining channel C Knob 5 Repeat for remaining filters 6 Reconnect power 1 Check operation of the range hood by turning the power on blower indicator 2 Push the right hand button L in to turn the lights on push in again to turn lights off 3 Push the left hand button 1 in to turn the blower on NOTE This button must be pushed in for the blower to operate at any speed The blower indicator light will light up to indicate blower is on and the blower will operate at low speed 4 Push button 2 to operate the blower at medium speed Push button 3 to operate blower at high speed 6 Push button 1 to turn blower off e RANGE HOOD USE The hood is designed to remove smoke cooking vapors and odors from the cooktop area For best results start the hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the kitchen Hood control panel The hood controls are located on the right hand front surface of the hood blower indicator Operating the light 1 Push
33. l or plumbing codes or use of products not approved by KitchenAid Replacement parts or repair labor costs for units operated outside the United States or Canada Pickup and delivery This major appliance is designed to be repaired in the home Repairs to parts or systems resulting from unauthorized modifications made to the appliance Expenses for travel and transportation for product service in remote locations The removal and reinstallation of your appliance if it is installed in an inaccessible location or is not installed in accordance with published installation instructions A ooN DISCLAIMER OF IMPLIED WARRANTIES LIMITATION OF REMEDIES CUSTOMER S SOLE AND EXCLUSIVE REMEDY UNDER THIS LIMITED WARRANTY SHALL BE PRODUCT REPAIR AS PROVIDED HEREIN IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO ONE YEAR OR THE SHORTEST PERIOD ALLOWED BY LAW KITCHENAID SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES SOME STATES AND PROVINCES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LIMITATIONS ON THE DURATION OF IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS SO THESE EXCLUSIONS OR LIMITATIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE OR PROVINCE TO PROVINCE Outside the 50 United States and Canada this warranty does not apply Contact your au
34. lie Registered trademark trademark of KitchenAid U S A KitchenAid Canada licensee in Canada 10 2005
35. nnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes amp standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other utilities Ducted systems must always be vented outdoors CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls ceilings attics crawl spaces or garages WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE m Never leave the surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings m Always turn hood ON
36. ns la rainure de retenue 4 Ins rer l extr mit se trouve le bouton et faire tourner le bouton vers la droite pour caler le filtre en place s 7 A Fente de la tige de verrouillage B Rainure de retenue C Bouton R p ter ces op rations pour les autres filtres Reconnecter la source de courant lectrique Mettre l appareil sous tension pour v rifier le bon fonctionnement de la hotte t moin de fonctionnement du ventilateur 1 L Appuyer sur le bouton de droite L pour commander l allumage des lampes appuyer de nouveau sur ce bouton pour commander l extinction Appuyer sur le bouton de gauche 1 pour commander mise en marche du ventilateur NOTE Quelle que soit la vitesse s lectionn e pour le ventilateur il faut que ce bouton soit enfonc pour que le ventilateur fonctionne Le t moin de fonctionnement du ventilateur s illumine alors et le ventilateur fonctionne basse vitesse Appuyer sur le bouton 2 pour s lectionner la vitesse moyenne Appuyer sur le bouton 3 pour s lectionner la haute vitesse Appuyer sur le bouton 1 pour commander l arr t du ventilateur 25 UTILISATION DE LA HOTTE DE CUISINIERE ENTRETIEN DE LA HOTTE DE CUISINIERE La hotte est congue pour extraire fum e vapeurs de cuisson et odeurs au dessus de la table de cuisson Pour obtenir les meilleurs r sultats mettre le ventilateur de la hotte en marche
37. nt creates back pressure and air turbulence that gently reduce performance AWARNING I Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating Failure to do so can result in death or electrical shock IMPORTANT The hood must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition or Canadian Electrical Code CSA C22 1 If codes permit and a separate ground wire is used it is recommended that a qualified electrical installer determine that the ground path is adequate A copy of the above code standards can be obtained from National Fire Protection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland Ohio 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required A time delay fuse or circuit breaker is also recommended It is recommended that a separate circuit serving only this hood be provided Do not ground to a gas pipe B Check with a qualified electrician if you are not sure range hood is properly grounded E Do not have a fuse in the neutral or ground circuit E The range hood must be connected with copper wire only M The range hood should be connected directly to the fused disconnect or circuit breaker box through flexible armored or nonmetallic
38. nte d accessoires et de pi ces de rechange m Assistance sp cialis e au client langue espagnole malentendants malvoyants etc m Les r f rences aux concessionnaires compagnies de service de r paration et distributeurs de pi ces de rechange locaux Les techniciens de service d sign s par KitchenAid sont form s pour remplir la garantie des produits et fournir un service apr s garantie partout aux Etats Unis Pour localiser la compagnie de service d sign e dans votre r gion vous pouvez galement consulter les Pages jaunes Si vous avez besoin de pi ces de rechange Si vous avez besoin de commander des pi ces de rechange nous vous recommandons d employer uniquement des pi ces d origine Ces pi ces conviendront et fonctionneront bien parce qu elles sont fabriqu es avec la m me pr cision utilis e dans la fabrication de chaque nouvel appareil KitchenAid Pour localiser des pi ces de rechange d origine dans votre r gion t l phoner au Centre d interaction avec la client le au centre de service d sign le plus proche ou appeler le 1 800 442 1111 Pour plus d assistance Si vous avez besoin de plus d assistance vous pouvez crire KitchenAid en soumettant toute question ou probl me Customer Interaction Center c o Correspondence Dept 2000 North M 63 Benton Harbor MI 49022 2692 Dans votre correspondance veuillez indiquer un num ro de t l phone o l on peut vous joindre dans la journ e
39. nts dans ce manuel et sur votre appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous y conformer Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous signale les dangers potentiels de d c s et de blessures graves a vous et a d autres Tous les messages de s curit suivront le symbole d alerte de s curit et le mot DANGER ou AVERTISSEMENT Ces mots signifient Risque possible de d c s ou de blessure grave si vous ne A DANG ER suivez pas imm diatement les instructions Risque possible de d c s ou de blessure grave si vous AVERTISSEM ENT ne suivez pas les instructions Tous les messages de s curit vous diront quel est le danger potentiel et vous disent comment r duire le risque de blessure et ce qui peut se produire en cas de non respect des instructions IMPORTANTES INSTRUCTIONS DE SECURITE AVERTISSEMENT POUR REDUIRE LE RISQUE D INCENDIE CHOC ELECTRIQUE OU DOMMAGES CORPORELS RESPECTER LES INSTRUCTIONS SUIVANTES m Utiliser cet appareil uniquement dans les applications envisag es par le fabricant Pour toute question contacter le fabricant m Avant d entreprendre un travail d entretien ou de nettoyage interrompre l alimentation de la hotte au niveau du tableau de disjoncteurs et verrouiller le tableau de disjoncteurs pour emp cher tout r tablissement accidentel de l alimentation du circuit Lorsqu il n est pas possible de
40. ongueurs quivalentes pieds m tres de tous les composants utilis s dans le syst me La longueur quivalente du circuit ne doit pas d passer 35 pieds 10 7 m tres Composant du circuit Conduit rond dia 6 15 2 cm Coude 45 2 5 pi 0 8 m 9 90 5 0 1 5 Gy bouche de d charge murale Coude 90 lt x s pi 1 8 m gt Exemple de circuit ra d vacuation 2 pi 1 coude 90 5 pi 1 5 m m section droite de 8 2 4 m 8 pi 2 4 m 1 bouche de d charge murale Opi 0m Longueur quivalente totale du syst me 13 pi 8 9 m NOTE On d conseille l emploi d un conduit flexible Un conduit flexible peut susciter une r tro pression et des turbulences de l air ce qui r duit consid rablement la performance 20 A AVERTISSEMENT Risque de choc lectrique D connecter la source de courant lectrique avant l entretien Replacer pieces et panneaux avant de faire la remise en marche Le non respect de ces instructions peut causer un d c s ou un choc lectrique IMPORTANT La hotte doit tre correctement reli e la terre en conformit avec les codes et r glements locaux en vigueur ou en l absence d un tel code conform ment aux prescriptions de la plus r cente dition du National Electrical Code ANSI NFPA 70 ou du Code canadien des installations lectriques CSA C22 1 Si les codes en vigueur
41. r le cache chemin e fourni avec le kit d extension sur la 3 Enfiler he ch f le kit d ext section inf rieure du support de chemin e et de l armature d extension et le fixer au sommet de l armature d extension en 2 Par le dessous de la hotte brancher le connecteur du c blage utilisant les deux vis fournies voir l illustration A B 3 Ins rer chaque connecteur du c blage dans une moiti de boitier de protection en plastique noir C A Vis Extension du cache chemin e section sup rieure 24 C Cache chemin e section inf rieure 4 Pour chaque boitier de protection de connecteur placer moiti sup rieure sur la moiti inf rieure et visser les deux moiti s ensemble avec les quatre vis fournies A Vis Moiti s de boitier de protection de connecteur 5 Utiliser les deux vis longues fournies avec chaque boitier de protection pour fixer le boitier de protection assembl sur le rebord m tallique 1 Uniquement pour une installation avec recyclage installer le filtre charbon fourni avec le kit de chemin e pour recyclage derri re le filtre graisse central ins rer et immobiliser le filtre en place ES 2 Installer les filtres graisse utiliser les deux mains tirer d abord et faire tourner le bouton vers la gauche pour que la tige de verrouillage ne d passe pas du filtre 3 Ins rer l extr mit oppos e du filtre da
42. rrer la vis Installation avec d charge l ext rieur 1 Raccorder le conduit d vacuation sur la section du clapet anti reflux Assurer l tanch it des jointures avec du ruban adh sif pour conduits 2 Oter la feuille de plastique de protection des sections du cache chemin e 3 Enfiler la section sup rieure du cache chemin e sur le support de chemin e fixer au sommet du support avec deux vis fournies A Cache chemin e section sup rieure B Cache chemin e section inf rieure C Vis 4 Faire glisser la partie inf rieure du cache chemin e sur le support de chemin e et la partie sup rieure du cache chemin e Fixer sur le bas du support avec deux vis fournies Option de l installation avec recyclage kit n cessaire 1 ter la feuille de plastique de protection des sections du cache chemin e 2 Enfiler la section sup rieure du cache chemin e sur le support de chemin e fixer au sommet du support avec deux vis fournies 3 Placer le raccord de diversion fourni dans le kit sur l orifice de sortie du carter du moteur du ventilateur enfoncer pour r aliser une bonne connexion Veiller orienter les sorties du raccord de diversion parall lement aux c t s du carter du ventilateur r aliser ainsi l alignement entre les sorties du raccord de diversion et les ouvertures du cache chemin e dans la partie inf rieure de la chemin e A Raccord de diversion B Moteur du
43. s four 12 volt 20 watt halogen lamps Turn off the range hood and allow the halogen lamps to cool Replace bulb using a tissue to handle bulb or wearing cotton gloves Do not touch bulb with bare fingers 1 Disconnect power 2 Remove 2 screws from the circular metal trim around the lamp assembly 3 Pull the trim with the lamp assembly attached down far enough so that the lamp can be pushed out of the socket clips 4 Insert the new lamp into the socket clips and push the lamp and trim assembly back up into the hood 5 Replace the screws 6 Reconnect power Replacement Charcoal Filter Part Number 8285507 REQUESTING ASSISTANCE OR SERVICE If you need assistance or service in U S A Call the KitchenAid Customer Interaction Center toll free at 1 800 253 1301 Our consultants are available to assist you When calling Please know the purchase date and the complete model and serial number of your appliance This information will help us better respond to your request Our consultants provide assistance with Features and specifications on our full line of appliances Installation information Use and maintenance procedures Accessory and repair parts sales Specialized customer assistance Spanish speaking hearing impaired limited vision etc Referrals to local dealers service companies and repair parts distributors KitchenAid designated service technicians are trained to fulfill the
44. s indiqu es prennent en compte les valeurs minimales des d gagements de s paration n cessaires On doit disposer d une prise de courant lectrique reli e la terre Voir la section Sp cifications lectriques On recommande que la hotte soit fix e sur du bois massif 18 La hotte d extraction a t configur e l usine pour la d charge travers le toit ou travers le mur Pour une installation avec recyclage voir Installation avec recyclage la section Installation du cache chemin e On devra assurer l tanch it de toutes les ouvertures plafond et mur d coup es pour l installation de la hotte Dimensions du produit 12 m 06 cm 34 9 cm 2638 65 1 cm min 39 99 1cm max XY 69 9 cm 494 12 1 cm N 35 89 9 cm Kit de chemin e pour une installation avec recyclage dimensions Pour une installation avec recyclage on doit utiliser le kit de chemin e n 4396911 acier inoxydable ou n 4396912 m t orite Ces ensembles comprennent une nouvelle section inf rieure de cache chemin e rempla ant le cache chemin e fourni avec la hotte un filtre charbon et un raccord de diversion 12 Ve em 85 cm 34 9 cm 32 81 3 cm min 39 99 1 cm D gagements de s paration a respecter hauteur typique du plan de travail 36 91 4 T QY NOTE La chemin e de la hotte est r glable on peut l ajuster
45. sections droites et minimiser le nombre de coudes M Ne pas utiliser plus de trois coudes 90 M Veiller ce qu il y ait une section droite de conduit de 24 61 cm ou plus entre deux coudes si on doit utiliser plus de un raccord coud Ne pas connecter ensemble deux raccords coud s E Assurer l tanch it de chaque jointure du circuit d vacuation avec du ruban adh sif pour conduit Wi Utiliser un calfeutrant pour assurer l tanch it autour de bouche de d charge l ext rieur entre le conduit et l ouverture travers le toit ou le mur Installation dans une r gion climat froid Il convient d installer un clapet anti reflux additionnel pour minimiser les reflux d air froid et d installer au sein du circuit d vacuation un mat riau non m tallique isolant thermique pour minimiser la conduction de chaleur entre l ext rieur et l int rieur de la maison Par rapport l isolant thermique le clapet anti reflux devrait tre situ du c t froid L isolant thermique doit tre plac aussi pr s que possible de l endroit o le circuit d vacuation p n tre dans la partie chauff e de la maison Air d appoint Le code du b timent local peut exiger l utilisation d un systeme d introduction d air d appoint dans le cas o la capacit d extraction pieds cubes d air par minute de la hotte est sup rieure une valeur sp cifi e La valeur sp cifi e d bit d air en pieds cubes par minut
46. sheathed copper cable B A UL or CSA listed strain relief must be provided at each end of the power supply cable Wire sizes copper wire only and connections must conform with the rating of the appliance as specified on the model serial rating plate Wire sizes must conform to the requirements of the National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 0 M91 latest edition and all local codes and ordinances INSTALLATION INSTRUCTIONS Because of the size and weight of this island hood the chimney support must be securely attached to the ceiling Wi For plaster or drywall ceilings the chimney support must be attached to joists If this is not possible you must build a support structure behind the plaster or drywall Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed B Before making cutouts make sure there is proper clearance within the ceiling or wall for exhaust vent AWARNING Excessive Weight Hazard Use two or more people to move and install range hood Failure to do so can result in back or other injury 1 Select a flat surface for assembling the hood Cover that surface with a protective covering such as a blanket or cardboard during assembly NOTE Do not remove the plastic covering on the chimney covers at this time The covering protects t
47. sur le r cipient un couvercle bien ajust une t le biscuits ou un plateau m tallique POUR ETOUFFER LES FLAMMES puis teindre le br leur gaz ou lectrique VEILLER A EVITER LES BRULURES Si les flammes ne s teignent pas imm diatement EVACUER LA PIECE ET APPELER LES POMPIERS m NE JAMAIS PRENDRE EN MAIN UN R CIPIENT ENFLAMME vous risquez de vous br ler m NE PAS UTILISER D EAU ni un torchon humide ceci pourrait provoquer une explosion de vapeur br lante m Utiliser un extincteur SEULEMENT si I s agit d un extincteur de classe ABC dont on connait le fonctionnement I s agit d un petit feu encore limit l endroit o il s est d clar Les pompiers ont t contact s est possible de garder le dos orient vers une sortie pendant l op ration de lutte contre le feu Recommandations tir es des conseils de s curit en cas d incendie de cuisine publi s par la NFPA m AVERTISSEMENT Pour r duire le risque d incendie ou de choc lectrique ne pas utiliser ce ventilateur avec un quelconque dispositif de r glage de la vitesse semi conducteurs CONSERVEZ CES INSTRUCTIONS 17 EXIGENCES D INSTALLATION Rassembler les outils et pieces n cessaires avant de commencer l installation Lire et suivre les instructions fournies avec les outils indiqu s ici Outillage n cessaire niveau perceuse avec foret 11 4 3 cm m foret avant trou selon la m t
48. t holes Leave screw heads about 1 4 6 4 mm away from ceiling strips Ee a Ya 6 4 mm 13 If the extension kit is not being installed go to Complete Chimney Support Installation section Installing Chimney Extension Kit Optional 1 Remove chimney extension cover if factory assembled 2 Position the chimney extension over the chimney support so that the outside edges and the electrical holes line up 3 Attach the extension to the support using the 4 bolts supplied 9 Replace the four screws and tighten securely with the extension kit Tighten bolts securely A B Electrical Shock Hazard Disconnect power before servicing Replace all parts and panels before operating A Chimney extension frame Failure to do so can result in death or electrical shock B Chimney support C Bolt D Captive threaded insert 1 Disconnect power 2 Use twist on connectors and connect black wires together 3 Use twist on connectors and connect white wires together 1 Run wire through the 1 3 0 cm electrical hole in the ceiling AWARN i NG according to the National Electrical Code or CSA Standards and local codes and ordinances There must be enough power supply cable from the fused disconnect or circuit breaker box to make the connection in the hood s electrical wiring box 2 Use caulk to seal all openings NOTE Do not reconnect power until installation is complete
49. thorized KitchenAid dealer to determine if another warranty applies If you need service first see the Troubleshooting section of the Use amp Care Guide After checking Troubleshooting additional help can be found by checking the Assistance or Service section or by calling KitchenAid In the U S A call 1 800 422 1230 In Canada call 1 800 807 6777 10 05 Keep this book and your sales slip together for future Dealer name reference You must provide proof of purchase or installation date for in warranty service Address Write down the following information about your appliance to Phone number better help you obtain assistance or service if you ever need it You will need to know your complete model number and serial Model number number You can find this information on the model and serial number label plate located on your appliance Serial number Purchase date 14 WIRING DIAGRAM Q 0 1 MID MAX 0 1 1 1 1 1 1 1 L jam r immr lem b uud HANHOASNVHL IVGdIlOHO L diNV1 IVNOLLO3MIG 120 VAC LINE IN Pim X18 MOTOR GROUP VOLTAGE 120V 60 Hz 100V 50 60 Hz gt gt gt ttt 25 240 V 15 16 SECURITE DE LA HOTTE DE CUISINIERE Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importa
50. trique les vis apr s que le support de chemin e aura t fix au plafond 5 Soulever le support de chemin e jusqu sa position de service finale faire passer le c ble d alimentation lectrique travers le serre c ble 6 Positionner le support de chemin e placer l extr mit large des trous d accrochage au niveau des vis de fixation au plafond pousser ensuite le support de chemin e pour engager la partie troite des trous de fixation sur les vis Bien serrer les vis IMPORTANT Le support de chemin e doit tre solidement fix au plafond 7 D terminer la longueur n cessaire du support de chemin e 1 D connecter la source de courant lectrique 2 Connecter les conducteurs noirs ensemble utiliser un connecteur de fils vis 3 Connecter les conducteurs blancs ensemble utiliser un connecteur de fils vis 22 A AVERTISSEMENT Risque de choc lectrique Relier le ventilateur a la terre Brancher le fil reli a la terre a la vis verte reli e la terre dans boite de borne Le non respect de cette instruction peut causer un d c s ou un choc lectrique 4 Connecter le conducteur de liaison a la terre a la vis verte de liaison a la terre dans la boite de connexion A Vis de liaison a la terre B Conducteur de liaison a la terre Cable d alimentation lectrique 5 Bien serrer le serre cable 6 R installer le couvercle du boitier de connexion Bien se
51. u support de chemin e Utiliser un foret de 14 ou 3 0 cm pour percer le trou de passage du c ble d alimentation lectrique Pour une configuration avec d charge de l air l ext rieur d couper dans le plafond le trou de passage n cessaire pour le conduit d vacuation et installer le circuit d vacuation Voir la section Exigences concernant l vacuation Pour une configuration avec d charge de l air l ext rieur placer le clapet anti reflux rond dans l ouverture de sortie du carter du moteur du ventilateur Placer dans les 4 avant trous d j perc s les 4 vis fournies dans le sachet de pi ces de fixation au plafond du support de chemin e Laisser les t tes de vis environ 1 4 6 4 mm du plafond L 4 6 4 mm Si le kit d extension n est pas install consulter la section Achever l installation du support de chemin e Installation de l extension de chemin e option Enlever les parties de cache chemin e de l extension installation l usine 2 Positionner l extension de chemin e sur le support de chemin e veiller l alignement des bords externes et des trous de passage du c ble lectrique 21 3 Fixer l extension sur le support avec les 4 vis fournies avec 8 Oter les quatre vis et ajuster la longueur du support de l extension de chemin e Bien serrer les vis chemin e selon le besoin NOTE C est la seule section qui peut tre ajust e J
52. ue d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plafond un grenier un vide sanitaire ou un garage AVERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE UTILISER UNIQUEMENT DES CONDUITS M TALLIQUES AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR LA CUISINIERE m Ne jamais laisser un l ment de surface fonctionner puissance de chauffage maximale sans surveillance Un renversement d bordement de mati re graisseuse pourrait provoquer une inflammation et la g n ration de fum e Utiliser une puissance de chauffage moyenne ou basse pour le chauffage d huile Veiller toujours faire fonctionner le ventilateur de la hotte lors de la cuisson avec une puissance de chauffage lev e ou lors de la cuisson d un mets flamber savoir cr pes Suzette cerise jubil e steak au poivre flamb Nettoyer fr quemment les ventilateurs d extraction Veiller ne pas laisser la graisse s accumuler sur les surfaces du ventilateur ou des filtres Utiliser toujours un ustensile de taille appropri e Utiliser toujours un ustensile adapt la taille de l l ment chauffant AVERTISSEMENT POUR R DUIRE LE RISQUE DE DOMMAGES CORPORELS APRES LE DECLENCHEMENT D UN FEU DE GRAISSE SUR LA CUISINIERE APPLIQUER LES RECOMMANDATIONS SUIVANTES m Placer
53. ventilateur 4 Installer les deux pi ces d extension sur le raccord de diversion pousser jusqu la but e PSS A Pi ces d extension 23 5 pas utiliser la section inf rieure de cache chemin e fournie 4 Enfiler la section inf rieure du cache chemin e par dessus le avec la hotte utiliser le cache chemin e fourni avec le kit de support de chemin e et l extension du cache chemin e et la chemin e pour recyclage achat s par fixer en bas du support en utilisant les deux vis fournies 6 Enfiler la section inf rieure de cache chemin e pour recyclage par dessus le support de chemin e et la section sup rieure du cache chemin e Veiller ce que les extensions connect es sur le raccord de diversion soient align es avec les ouvertures du cache chemin e Fixer le cache chemin e avec les deux vis fournies 7T Emboiter les grilles en place A Extension de chemin e assembl e et install e sur la hotte avec cache chemin e fix 1 Soulever la hotte pour la placer contre le support de chemin e fixer la hotte sur le support avec quatre vis fournies Bien serrer les vis A Emplacement de la grille d vacuation B Installation du kit d extension de chemin e option 1 Enlever la feuille de plastique de protection des sections du cache chemin e 2 Jeter la section sup rieure du cache chemin e fournie avec la A Support de chemin e hotte B Hotte C Vis Enfile
54. when cooking at high heat or when flameing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flamb m Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter m Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING m SMOTHER FLAMES with a close fitting lid cookie sheet or other metal tray then turn off the gas burner or electric element BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP A FLAMING PAN you may be burned m DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if You know you have a class ABC extinguisher and you already know how to operate it The fire is small and contained in the area where it started The fire department is being called You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA WARNING To reduce the risk of fire or electrical shock do not use this fan with any solid state speed control device SAVE THESE INSTRUCTIONS INSTALLATION REQUIREMENTS Gather the required tools and parts before starting installation Read and follow the safety instructions provided with any tools listed
Download Pdf Manuals
Related Search
Related Contents
Manuseamento de Produtos Hortofrutícolas 1. indoor unit installation Manual notice d`utilisation radiateurs infrarouges wolff meier GeoVision GV-Data Capture Troubleshooting 21.46 MB 安全データシート MouseFiler-mde - Jean Pfister F-529-PDSL Installation Guide Copyright © All rights reserved.
Failed to retrieve file