1. Kenmore Range Hood Installation Manual Manual de uso y cuidado instalaci n Models 233 51840591 30 wide Stainless Modelos 233 51841591 30 wide White 233 51844591 30 wide Bisque 233 51848591 30 wide Almond 99043202D Sears Roebuck and Co Hoffman Estates IL 60179 U S A www sears com EEE t y af af SOLOS SESS OCS Oe SCS OES OCR SOLO tf af Ey t tf Ey af t E Ey af Ey E EE Waan a PA eo O A 2 STORY MSPC an a N 2 RD UE ON aano oei 3 SAMA is 3 Parts Included WHPR HOOO cuca adas 4 Parts Not Included With Hood oocccccoocccconoccnononinoccnononnnnos 4 TOS NGO ea n 4 Equivalent Duct Length Chart 00 i ccccce esse eeeeee ees 5 Prepare The Hood Location ooo ceccceecseeseseeeeseeees 6 Prepare TNE HOOG ni ici 7 8 Connect TIe WI 9 instal The FOOG arcada dad 10 SONICO RAS condi 11 lf within 1 year from the date of installation any part of this range hood fails to function properly due to a defect in mate rial or workmanship Sears will repair the part or furnish and install a new part free of charge FULL 30 DAY WARRANTY ON FINISH ON PAINTED OR BRIGHT METAL PARTS If within 30 days from the date of installation the finish on any painted or bright metal parts of this range hood is defective in material or workmanship Sears will furnish and install a new part free of charge WARRANTY SERVICE IS AVAILABLE BY CONTACTING
2. Acodado con alero corto a y ngulo a la if derecha Largo equivalente 4 6 m 15 pies N Modelo Sears ji Tapon de pared Largo equivalente 14 m 45 pies 2 1 m 7 pies sin regulador de tiro A Modelo Broan 431 P eae x 10 pulg Modelo Y fer Acodado i Sears 59091 ft con alero largo Tap n de techo y ngulo a la acepta ducto de 7 pulg redondo o de 3 44 pulg x 10 pulg Largo equivalente 9 1 m 30 ples 2 1 m 7 pies sin regulador de tiro Modelo Broan 419 Acodado redondo Sy HF derecha de 6 pulg oe Largo equivalente Largo equivalente 46m 15 pies 2 4 m 8 pies 1 Modelo Broan 415 Acodado redondo Accesorios para conductos modelo Sears disponibles llamando a de 7 pulg Sears at 1 800 4 MY HOME Largo equivalente T i roe E a ps a 3 EeCesSorigos para COnGUCIOS MoGo roari ISponi es HamandoO a 2 4 m 8 pies 1 800 558 1711 Modelo Sears 59581 3 pulg x 10 pulg a 6 pulg Transici n redondo Largo equivalente 1 7m 5 5 pies 4 Modelo Broan 412H 314 pulg x 10 pulg a 7 pulg Transicion redondo Largo equivalente 1 7m gt 5 ples u peiod enueIes Pen Y BZaIMuilT Oo F B a amp Oo E O 1 Determine si la descarga de la campana ser vertical horizontal o sin conducto En el caso de descarga vertical u horizontal tienda los conductos entre el lugar donde se
3. ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities 6 To reduce the risk of fire or electric shock do not use this range hood with an additional speed control device 7 Ducted fans must always be vented to the outdoors 8 To reduce the risk of fire use only metal ductwork 9 Use with approved cord connection kit only 10 This unit must be grounded TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE 1 Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings 2 Always turn hood ON when cooking at high heat or when cooking flaming foods 3 Clean ventilating fans frequently Grease snould not be allowed to accumulate on fan or filter 4 Use proper pan size Always use cookware appropriate for the size of the surface element 2 STIC CO KIN ON A WARNING 44 4 TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING 1 SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS Ifthe flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result 4 Use an e
4. in x 10 in duct Equivalent length 30 ft 7 ft w o damper f Sears Model Ducting Accessories available by calling j Sears at 1 800 4 MY HOME Broan Model Ducting Accessories available by calling 1 800 558 1711 IS gt S ES EN pr nm BB gy ES Me Ke al Eo 1 Determine whether hood will discharge vertically hori zontally or non ducted For vertical or horizontal discharge run ductwork between the hood location and a roof cap or wall cap For best results use a minimum number of transitions and elbows 2 Use these diagrams for proper placement of ductwork and electrical cutout in cabinet or wall For a non ducted installation DO NOT cut a duct access hole 3 Run house wiring between service panel and hood location ROOF CAP qa a 3 X 10 DUCT For vertical discharge ichaadaahahaheaededabeel 7 EN E SOFFIT _JN a AA Ng is N LS ZEA hake N HOUSE WIRING CABINET N La Top or Back of hood A cd _ A WALL CAP 24 30 ABOVE COOKING SURFACE 314 X 10 DUCT For horizontal discharge 3 X 10 HOOD MOUNTING SCREWS 4 VERTICAL DUCTING 131546 lacas f CABINET FRONT y El TEO DUCT gt a is ACCESSHOLE 5 6 ELECTRICAL WOOD SHIMS ACCESS HOLE recessed bottom dios in cabinet bottom cabinets only WOOD SHIMS recessed bottom cabinets only a MOE HORIZONTAL DUCT g
5. DEL GABINETE L 4 9 orn J 9 5 om y ORIFICIO DE ACCESO DEL au 4 CONDUCTO HORIZONTAL e GABINETE va cn mg 19 1 om all 35 4 om TORNILLOS PARA ii MONTAJE DE LA L NEA ORIFICIO DE ACCESO CAMPANA 4 CENTRAL PARA D e OS PREPARE LA CAMPANA 1 Retirar la cinta adhesiva de embarque de la punta de la CINTA campana ADHESIVA EnUueJeE pepinbes 2 Quite la tapa del cableado del interior de la campana Coloque la tapa y el tornillo de montaje a un lado O OPCI N Si se instalar la campana sin conductos e Compre un kit sin conductos que contenga un filtro e de cocina limpio e Instale el filtro de cocina limpio detr s del filtro de VENTE malla de aluminio e Continue con el paso 5 e uolgeied Vea la pagina 4 para informacion sobre el Kit sin Conducto El Kit sin Conducto esta disponible llamando a Sears al 1 800 4 MY HOME 4 ezaidull SOLO PARA INSTALACIONES AS 7 ie CON DUCTO e CONDUCTO RECTANGULAR Quite para descarga vertical de 8 3 x 25 4 cm 3 Quite el agujero o agujeros ciegos para conducto apropiados de la parte superior o de la parte posterior de la campana M a S 9 O AGUJERO CIEGO POSTERIOR PARA CONDUCTO RECTANGULAR Quite para descarga horizontal de 8 3 x 25 4 cm p SEZOld OJSIA1OS Y 17 S LO PARA INSTALACIONES CON CONDUCTOS BORDE DE LA PARTE SUPERIOR POSTERIOR as Coloque el conectador del regulador de tiro
6. INCENDIO DE GRASA EN LA ESTUFA OBSERVE LO SIGUIENTE 1 APAGUE LAS LLAMAS con una tapa ajustada plancha para galletitas o charola decorativa y luego apague la hornilla TENGA CUIDADO DE EVITAR QUEMADURAS Si las llamas no se apagan de inmediato EVACUE EL LUGAR Y LLAME AL DEPARTAMENTO DE BOMBEROS 2 NUNCA LEVANTE UNA SARTEN QUE ESTE EN LLAMAS Usted se podr quemar 3 NO UTILICE AGUA incluyendo toallas de cocina mojadas puede resultar una explosi n de vapor violenta 4 Utilice un extintor SOLAMENTE si A Usted sabe que tiene un extintor de clase ABC y ya sabe utilizarlo B El incendio es pegue o y contenido dentro del area donde se inici C Los bomberos han sido avisados D Usted puede combatir el incendio con una salida a su espalda Basado en las recomendaciones para Seguridad en la Cocina publicadas por NFPA de los EE UU PRECAUCI N amp 1 Solamente para uso general de ventilaci n No utilice para descargar materiales peligrosos o materiales y vapores explosivos 2 Para evitar da os al cojinete del motor y evitar que las paletas del ventilador emitan mucho ruido o est n fuera de equilibrio mantenga el motor libre de pelusa polvo etc 3 Para obtener mejores resultados en la captura de impurezas la parte superior de la campana debe estar montada de forma tal que la campana quede de 61 a 76 cm de distancia de la superficie de la estufa 4 Use s lo kits de cable de conexi n para campa
7. conducto de 8 3 x 25 4 cm 3 4 x 10 sobre la abertura del agujero ciego Asegurese de que el pivote del regulador de tiro quede lo m s cerca posible del borde superior posterior de la campana Quite la cinta adhesiva de la aleta del regulador de tiro 8 3 x 25 4 cm CONECTOR DEL REGULADOR DE TIRO CONDUCTO PIVOTE S LO PARA INSTALACIONES SIN CONDUCTOS VENTILACI N 5 Retire la cubierta de ventilaci n de la parte delantera de la campana 6 Quite el agujero ciego para los cables el ctricos ya sea el superior o el posterior e instale una grapa para cable el ctrico aprobada Bs hs ds es a a AGUJERO CIEGO PARA GRAPA DEL CABLE CABLES ELECTRICO ELECTRICOS 18 CONECTE EL CABLEADO ADVERTENCIA Para reducir el riesgo de descargas el ctricas aseg rese de apagar el interruptor de alimentaci n el ctrica en el panel de servicio Bloquee o rotule el panel de servicio para evitar que alguien conecte accidentalmente la energ a el ctrica 1 Conecte el cableado de la casa 120 VCA a la campana Si fuera necesario use un pedazo de cart n para proteger la superficie de la estufa Hay un Kit de Cable disponible que permite que se enchufe la campana en una toma de pared est ndar de 120 VCA Vea la p gina 4 para informaci n sobre el Kit de Cable El Kit de Cable est disponible llamando a Sears al 1 800 4 MY HOME Use s lo kits de cable de conexi n
8. instalar la campana y el tap n de techo o el tap n de pared Para obtener los mejores resultados utilice una cantidad minima de transiciones y codos Utilice estos diagramas para colocar adecuadamente los conductos y hacer el corte exacto para la conexi n el ctrica en el gabinete o en la pared En el caso de aquellas instalaciones en sistemas sin conductos NO haga ning n orificio de acceso para el conducto Guie las conexiones del cableado de la casa entre el panel de servicio y el lugar donde instalar la campana 16 TAPA DE TECHO 83cmx254cm o CONDUCTO REDONDO E 17 8 cm AGARRE SE CLALALATA e eon PE AF N RN IF NA RE UN N CABLEADO EL CTRICO N LDE LA CASA ANE a F j Parte superior o posterior l LA A de la campana P CAMPANA TAP N DE PARED 45 70ma60 90m o SOBRE LA SUPERFICIE FARA CONCINAR CONDUCTO DE 8 3 em x 25 4 cm Para descarge horizontal m ao ZEEE SISTEMA VERTICAL DE CONDUCTOS DE 8 3 cm x 25 4 cm 3 4 x 10 TORNILLOS PARA MONTAJE DE LA CAMPANA 4 35 4 orn or pn 35 4 om E FRENTE DEL GABINETE ORIFICIO DE ACCESO DEL CONDUCTO VERTICAL 2 8 cm ORIFICIO DE E CU AS DE MADERA mga PARA COBLES EL CTRICOS s lo gabinetes con CENTRAL en la base del gabinete base empotrada SISTEMA HORIZONTAL DE CUNAS DE MADERA CONDUCTOS DE s lo gabinetes con base empotrada 8 3 cm x 25 4 cm 3 4 x 10 FRENTE
9. para campana de cocina cuyo uso ya se haya estudiado y aprobado con este modelo de campana 2 Conecte el cable negro del suministro de la casa al cable negro de la campana el cable blanco del suministro de la casa al cable blanco de la campana y la conexi n a tierra del suministro dom stico debajo del tornillo verde de conexi n a tierra Ajuste bien la grapa para cable el ctrico al cableado de la casa 3 Vuelva a instalar la tapa de la conexi n el ctrica 19 CABLEADO DE LA CASA 120 VCA CART N Usar para proteger la superficie de la estufa TORNILLO VERDE DE CONEXION A TIERRA O e uolgelied 4 ezaidull E1SU Fo Fe 2 a Y N Y Q OPSIAIOS INSTALE LA CAMPANA 1 Cuelgue la campana de los 4 tornillos de montaje que se encuentran en la bolsa de piezas Deslice la campana hacia la pared hasta que los tornillos de montaje queden conectados en el extremo angosto de los 4 orificios tipo bocallave Apriete fijamente los tornillos de montaje del ventilador El empujar el filtro o la paleta del ventilador puede hacerla interferir con otras piezas de la campana PRECAUCI N No presione el filtro o la paleta ORIFICIO TIPO TORNILLO DE BOCALLAVE MONTAJE 4 4 S LO PARA INSTALACIONES _ NBA CON CONDUCTO a CONDUCTOS SISTEMA DE CONDUCTOS 2 Conecte el sistema de conductos a la campana Use cinta para conductos para fijar y sellar las uniones herm ticame
10. Installa 75 W Maximum Light Bulb Purchase bulb locally Gently squeeze Light Lens Legs to remove and replace lens CAUTION Bulbs may be hot Refer to bulb pack aging for further information 4 Make sure fan blade turns freely Turn on power at service panel and test for proper operation 75 W MAXIMUM LIGHT BULB 10 P IN A NO Ee AAA LO A 97006184 Outlet Box Cover 99170245 8 18 x 3 8 Phillips Truss Sheet Metal Screw 2 Required 97010966 Bulb Holder with Wires 99110437 Light Lens 97011217 Screw Nut Kit Includes 2 10 16 x 500 Screws and 2 10 16 Sheet Metal Nuts 99020272 Fan Blade 99260428 46 32 Locking Nuts 2 Required 98005568 Motor Mounting Bracket 97011224 Motor Assembly Includes Key Nos 7 8 amp 9 97006931 Aluminum Filter 99420472 Filter Retainer 99150415 8B x 1 4 Hex Head Sheet Metal Screw 2 Required 98005221 Damper Flap 99100379 Damper Bushing 97005544 Damper Assembly Includes Key Nos 15 amp 16 97014275 Plastic Nameplate Assembly 99360232 Knob 2 Required 99030285 Solid State Motor Switch 99260422 Nut 3 8 32 97016438 Light Switch 99260470 Nut 15 32 32 for Light Switch 97013649 Motor Receptacle with Wires 99150471 10 32 x 1 2 Green Ground Screw 97007501 Diode Assembly Light Bulb 75 Watt Not Included 99043202 Installation Instructions ee O ON O 014 Go Po uoneyeysuy Standard Hardware May be purchased locally No
11. S ESTADOS UNIDOS Esta garant a es v lida nicamente si este producto se encuentra en uso dentro de los Estados Unidos Esta garant a le confiere derechos legales espec ficos y Ud puede tener ademas otros derechos que var an de estado a estado Sears Roebuck and Co Dept 817WA Hoffman Estates IL 60179 A PREVISTO PARA COCINAR DOM STICO SOLAMENTE A ADVERTENCIA A PARA REDUCIR EL RIESGO DE INCENDIO CHOQUE EL CTRICO O LESION A PERSONAS OBSERVE LO SIGUIENTE 1 Utilice esta unidad s lo en la manera prescrita por el fabricante Si tiene usted alguna pregunta comuniquese con el fabricante a la direcci n o al t letono indicados en la garant a 2 Antes de efectuar alg n servicio o limpieza se debe desconectar la corriente el ctrica en el armario de circuitos y asegurarlo con llave para evitar que la corriente sea conectada accidentalmente Cuando el medio de desconexi n del servicio no puede ser trabado sujete un dispositivo de advertencia evidente tal como una etiqueta al panel de servicio 3 Todo trabajo do instalaci n y cableado el ctrico debe ser realizado por personal calificado y de acuerdo con todos los c digos y normas pertinentes incluyendo los c digos y normas relacionados con construcci n clasificada para incendio 4 Aire suficiente es necesario para facilitar la combusti n adecuada y la salida apropiada de gases por la chimenea de la unidad y para evitar corrientes d
12. THE NEAREST SEARS SEVICE CENTER DEPARTMENT LIN THE UNITED STATES This warranty applies only while this product is in use in the United States This warranty gives you specific legal rights and you may have other rights which vary from state to state Sears Roebuck and Co Dept 817WA Hoffman Estates IL 60179 WARNING amp TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in the manner intended by the manufac turer If you have questions contact the manufacturer at the address listed in the warranty 2 Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated codes and standards 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers
13. chato y Phillips Cinta m trica Ly 1 4 N Ajustador Sy de tuercas ya Cinta Pelador de WA pra adhesiva cable f p OS para conductos 14 Las campanas de cocina Kenmore fueron dise adas para su desempe o eficiente cuando se las sujeta a largos recorridos de conducto Como punto de referencia esta campana funcionar a aproximadamente el 80 de su flujo de aire nominal cuando se le sujeta 61 m 200 pies equivalentes de conducto redondo de 17 8 cm 7 Utilice esta cuadro para calcular el largo equivalente de conducto de su sistema Modelo Broan 401 Conducto recto 3 4 pulg x 10 pulg x 2 pies de largo Largo equivalente 0 61 m 2 pies Modelo Broan 428 34 pulg x 10 pulg ge BAcodado con ngulo a la derecha Largo equivalente 2 6 m 8 5 pies Modelo Broan 429 3 pulg x 10 pulg Acodado plano con ngulo a la derecha Largo equivalente 7 3 m 24 pies Modelo Sears 59691 6 pulg Tapon de pared redondo Largo equivalente 10 m 34 pies 1 8 m 6 ples sin regulador de tiro Modelo Broan 647 7 pulg Tap n de pared redondo Largo equivalente 10 m 34 pies 1 8 m 6 pies sin CU Modelo Broan 406 Conducto recto 6 pulg alrededor x 2 pies de largo Largo equivalente 0 61 m 2 pies CU Modelo Broan 407 Conducto recto 7 pulg alrededor x 2 pies de largo Largo equivalente 0 61 m 2 ples regulador de tiro A Modelo Broan 430 y 3 pulg x 10 pulg
14. ckwise to second position for normal lighting Rotate the switch clockwise to the third position for a night light fa WARNING To reduce the risk of electric shock A disconnect from power supply before clean ing Aluminum mesh filter Clean frequently using hot water and a mild detergent or in your dishwasher The aluminum mesh filter snould be washed approximately every month depending on the amount of us age Wash more often if your cooking style generates greater grease like frying foods or wok cooking Non ducted filter Clean Cooking hoods only available separately see page 4 Clean filter surfaces frequently with a damp cioth and a mild detergent DO NOT immerse filter in water or put in dish washer The special Clean Sense feature indicates when the filter is to be replaced The blue and yellow Strips will blend to green when it is time to change the filter The Clean Sense feature works best when facing toward the cooking surface Painted hood surfaces Wiping regularly with mild soap detergent and warm water should protect painted hood surfaces Be cautious about us ing New and Improved cleaning agents Your hood is installed over hot cooking equipment Most chemicals found in clean ing agents react with heat to loosen paint Stainless steel hood surfaces Stainless steel hoods should be washed regularly with a clean cloth warm water and mild soap or dish detergent Clean in the directio
15. damente cada mes dependiendo de su uso L velos con mayor frecuencia s su forma de cocinar genera m s grasa como por ejemplo frituras o wok Filtros sin conducto campanas de cocina limpia solamente disponibles por separado ver p gina 4 Limpie frecuentemente las superficies de los filtros con un pa o h medo y un detergente suave NO sumerja los filtros en agua ni los coloque en el lavaplatos La caracter stica especial Clean Sense Detecci n de limpieza indica cuando se debe reemplazar el filtro Las l neas azules y amarillas se combinar n produciendo un color verde cuando sea el momento de cambiar el filtro La caracter stica Clean Sense funciona mejor cuando se coloca orientada hacia la superficie para cocinar Superficies pintadas de la campana Limpiarlas peri dicamente con agua tibia y un jab n detergente suave proteger las superficies pintadas de la campana Tenga cuidado si usa agentes de limpieza Nuevos y Mejorados Su campana est instalada sobre equipos de cocina calientes La mayor a de los productos qu micos que contienen los agentes de limpieza calentar n y aflojaran la pintura Superficies de acero inoxidable de la campana Se debe lavar las campanas de acero inoxidable peri dicamente con un pa o limpio agua tibia y un jab n o detergente para platos suave Limpielas en la direcci n de las l neas de pulido Enju guelas bien con agua limpia y s guela de inmediat
16. e alre invertidas Siga las instrucciones y medidas de seguridad del fabricante del equipo y de las sociedades profesionales de equipos do calentadores y los reglamentos de seguridad locales 5 Alcortar o perforar la pared o el techo no da e el cableado el ctrico y otros servicios p blicos ocultos 6 Para reducir el riesgo de incendio o de descarga el ctrica no utilice esta campana con un dispositivo de control de velocidad adicional 7 Los ventiladores con conducto deber n siempre tener una salida hacia el exterior 8 Para reducir el riesgo de incendio use s lo conductos de metal 9 Uso con el kit aprobado del la conexi n de la cuerda solamente 10 Esta unidad se debe instalar con conexi n a tierra PARA REDUCIR EL RIESGO DE UN INCENDIO POR GRASA EN LA ESTUFA 1 Nunca deje las unidades de superficie sin supervisi n cuando tengan ajustes altos Los reboses pueden provocar humo y derrames grasosos que se pueden incendiar Caliente lentamente el aceite en un ajuste bajo o medio 2 Siempre ENCIENDA la campana cuando cocine con alta temperatura o cuando cocine alimentos que se puedan incendiar 3 Limpie con frecuencia los ventiladores No debe permitir que la grasa se acumule en el ventilador ni en el filtro 4 Utilice un sart n de tama o adecuado Siempre utilice el utensilio adecuado al tama o del elemento do superficie 12 ADVERTENCIA amp PARA REDUCIR EL RIESGO DE LESIONES A PERSONAS EN CASO DE
17. el regulador incluye claves nos 15 16 Unidad de placa de identificaci n de pl stico Perillas se necesitan 2 Interruptor de estado s lido del motor Tuerca 3 8 32 Interruptor de luz Tuerca 15 32 32 para interruptor de luz Recept culo del motor con cables Tornillo verde de conexi n a tierra No 10 32 x 1 2 Unidad de diodos Bombilla de luz de 75 watts no incluida Instrucciones para la instalaci n es est ndar pueden comprarse localmente No ilustrado 21 uolselad uoloe Ko gt amp tad amp peer ay e Bzalduily e 3 E a 2 22 23 Your Home For repair in your home of all major brand appliances lawn and garden equipment or heating and cooling systems no matter who made it no matter who sold it For the replacement parts accessories and owner s manuals that you need to do it yourself For Sears professional installation of home appliances and items like garage door openers and water heaters 1 800 4 MY HOME 1 800 469 4663 Call anytime day or night U S A and Canada www sears com www sears ca Our Home For repair of carry in items like vacuums lawn equipment and electronics call or go on line for the location of your nearest Sears Parts Repair Center 1 800 488 1222 Call anytime day or night U S A only www sears com To purchase a protection agreement U S A or maintenance agreement Ca
18. n of the polish lines Rinse well with clear water and wipe dry immediately You may wish to apply light oil used for furniture polishing to emphasize it s bright finish Fan assembly Fan blade can be cleaned with a damp cloth and mild deter gent Use care when cleaning fan blade it must not become bent or misaligned DO NOT ALLOW WATER TO ENTER MO TOR Make sure all surfaces are completely dry before re installing filters and restoring power Motor is permanently lubricated Do not oil or disassemble motor uo ejjersuj SIJBg 9914198 Sujueo Aluminum Grease Filter Parts Bag 4 hood mounting screws inside Light Bulb 75 W Maximum 1 per hood Purchase locally OPTIONAL PARTS purchase separately Non Ducted Kit Clean Cooking Filter 1 per hood Sears Part No 50183 Splashplate Sears Part Nos 58120 30 Black Bisque 58128 30 White Almond 58129 30 Stainless Cord Kit Allows hood to be plugged into a standard 120 VAC wall outlet Sears Part No 233 22HCK44D Ducting Accessories See Equivalent Duct Length Chart on page 5 for Ducting Accessory Model Nos Screwdriver Flat amp Phillips Tape Measure 1 4 Nutdriver J Y Q Duct Wire Tape Stripper Kenmore range hoods are designed to perform efficiently when attached to long runs of duct As a point of reference this hood will function at approximately 80 of its rated air flow when 200 e
19. na de cocina cuyo Uso ya se haya estudiado y aprobado con este modelo de campana 5 Por favor lea la etigueta de especificaciones del producto para mayores informaciones y requerimientos Si se E la campana sin conducto Con su distribuidor o minorista local compre un filtro sin conducto e inst lelo debajo del filtro de aluminio FAN LIGHT Ventilador El interruptor del ventilador es un control de velocidad de estado s lido Gire el interruptor en el sentido de las manecillas del reloj para llevarlo desde la posici n de encendido ON hasta la de velocidad alta HIGH Contin e girando el interruptor en el sentido de las manecillas del reloj para reducir la velocidad del ventilador Luz El interruptor de la luz tiene 3 posiciones La luz se apaga OFF cuando se gira el interruptor totalmente en sentido contrario a las manecillas del reloj Gire el interruptor hasta la segunda posici n en el sentido de las manecillas del reloj para la iluminaci n normal Gire el interruptor hasta la tercera posici n en el sentido de las manecillas del reloj para la iluminaci n nocturna ADVERTENCIA Para reducir el riesgo de una descarga el ctrica desconecte el suministro el ctrico antes de limpiar la unidad Filtros de malla de aluminio Limpie frecuentemente los filtros con agua caliente y un detergente suave Los filtros se pueden lavar en lavaplatos Se debe lavar los filtros de malla de aluminio aproxima
20. nada on a product serviced by Sears 1 800 827 6655 U S A 1 800 361 6665 Canada Para pedir servicio de reparacion Au Canada pour service en francais a domicilio y para ordenar piezas 1 800 LE FOYER 1 888 SU HOGAR 1 800 533 6937 1 888 784 6427 www sears ca SEARS Registered Trademark Trademark Service Mark of Sears Roebuck and Co O Marca Registrada Marca de F brica Marca de Servicio de Sears Roebuck and Co MC Marque de commerce MP Marque d pos e de Sears Roebuck and Co Sears Roebuck and Co
21. nte PATAS DE LA LENTE DE LUZ 3 Instale una bombilla de luz con un m ximo de 75W Compre la bombilla localmente Apriete las patas de la lente de luz suavemente para retirar y reemplazar la lente PRECAUCI N Las bombillas de luz pueden A ser calientes Consulte el embalaje de las bombillas informaci n adicional 4 Aseg rese que las paletas del ventilador giren libremente Conecte la energ a en el panel de servicio y revise el funcionamiento adecuado de la campana BOMBILLA CON UN MAXIMO DE 75W 20 Herra J IEZA E NO E NO 97006184 99170245 197010966 199110437 97011217 99020272 99260428 198005568 97011224 197006931 99420472 99150415 98005221 99100379 99260422 97016438 99260470 97013649 99150471 97007501 MAF HAE me em mee mm mer me 99043202 Tapa de la caja de enchufe Tornillo met lico Phillips para chapa met lica de enrejado de 8 18 x 3 8 se necesitan 2 Soporte de bombilla con cables Lente de luz Kit de tornillos tuercas incluye 2 tornillos No 10 16 x 500 y 2 tuercas de chapa met lica No 10 16 Paleta de ventilador Tuercas de retenci n No 6 32 se necesitan 2 Abrazadera de montaje del motor Conjunto del motor incluye claves nos 7 8 y 9 Filtro de aluminio Retenedor de filtro Tornillos para l mina No 8B x 1 4 con cabeza hexagonal se necesitan 2 Aleta del regulador de tiro Manguito del regulador de tiro Unidad d
22. o con un pa o Podr aplicarles un aceite leve utilizado para lustrar muebles para realzar su acabado lustroso Montaje del ventilador Se puede limpiar las paletas del ventilado con un pa o h medo y un detergente suave Tenga cuidado cuando limpie la paleta del ventilador No se debe doblar ni desalinear NO PERMITA LA ENTRADA DE AGUA EN EL MOTOR Aseg rese de que todas las superficies est n completamente secas an tes de volver a colocar los filtros y conectar la energia el ctrica El motor est permanentemente lubricado No lubrique ni desmonte el motor 13 eysuy uoloe ezeldu 4 p SEZOld OJSIAJOS E Bombilla de luz M ximo 75 W 1 por campana Compre localmente PIEZAS OPTATIVAS compra separada Bolsa de piezas 4 tornillos de montaje de la campana adentro Kit sin conductos Filtro limpio para cocina 1 por campana Pieza Sears No 50183 Placa posterior Piezas Sears Nos 58120 30 Negro Beige 58128 30 Blanco Almendra 58129 30 Inoxidable Kit de cable Permite que se enchufe la campana en una toma de pared est ndar de 120 VCA Pieza Sears No 233 22HCK44D Accesorios para conductos Vea el Cuadro de largo equivalente de conducto de la p gina 5 para obtener los Nos de Modelos de Accesorios para Conductos 1 Las Piezas no incluidas con la campana est n disponibles llamando a Sears al 1 800 4 MY HOME _ Destornillador
23. of electric shock make sure power is switched off at the service panel Lock or tag service panel to prevent power from being switched on acci dentally 1 Connect House Wiring 120 VAC to hood Use a piece of Cardboard to protect the cooktop if necessary A Cord Kit is available which enables the hood to plug into a standard 120 VAC wall outlet See page 4 for Cord Kit information Cord Kit available by calling Sears at 1 800 4 MY HOME Use only with range hood cord connection kits that have been investigated and found accept able for use with this model range hood 2 Connect house black to hood black wire house white to hood white wire and house ground under Green Ground Screw Securely tighten cable clamp onto house wiring 3 Replace wiring cover GROUND HOUSE WIRING 120 VAC CARDBOARD Use to protect cooktop 19 bulmues uoneyjelsul Y me 9 y ms 0 INSTALL THE HOOD 1 Hang hood from 4 Mounting Screws from parts bag Slide hood towards wall until mounting screws are engaged in narrow end of 4 Keyholes Tighten mounting screws securely CAUTION Do not push on filter or fan blade Pushing on the filter or fan blade may cause them to interfere with other hood parts KEYHOLE MOUNTING 4 SCREW 4 DUCTED INSTALLATIONS ONLY DUCTWORK 2 Connect Ductwork to hood Use Duct Tape to make joints secure and air tight LIGHT LENS 3
24. quivalent feet of 7 round ductwork is attached Use this chart to calculate the equivalent duct length of your system Broan Model 401 Straight Duct 3 in x 10 in x 2 fL long Equivalent length 2 ft CU Broan Model 406 Straight Duct 6 in round x 2 ft long Equivalent length 2 ft CU Broan Model 407 Straight Duct 7 in round x 2 ft long Equivalent length 2 ft Broan Model 419 6 in Round Elbow Equivalent length 8 ft Broan Model 415 7 in Round Elbow Equivalent length 8 it timmy Sears Model 59581 3 in x 10 in to Equivalent length 5 5 fl famn Broan Model 412H 34 in x 10 in to 7 in Round Transition Equivalent length 5 5 ft A 6 in Round Transition Broan Model 428 3 in x 10 in Right angle Elbow Equivalent length 8 5 ft Broan Model 429 3 in x 10 in Right angle Flat Elbow Equivalent length 24 ft 4 Broan Model 430 3V in x 10 in 2 Right angle E Short P Eave Elbow Equivalent length 15 ft y Broan Model 431 AA Iain x 10 in Right angle 2 Long Eave Elbow Equivalent length 15 ft Sears Model 59691 6 in Round Wail Cap Equivalent length 34 ft 6 ft w o damper Broan Model 647 7 in Round Wall Cap Equivalent length 34 ft GAL w o damper Sears Model 59391 3 in x Equivalent length 45 ft 7 ft w o damper Sears Model 59091 Root Cap accepts 7 in round or 3
25. t F ME IA O BOTTOM b 514 mote 5514 Law 772 UNI ELECTRICAL MOUNTING CENTER SCREWS 4 LINE ACCESS HOLE in wall 1 Remove Shipping Tape from nose of hood 2 Remove Wiring Cover from inside the hood Set cover and mounting screw aside if hood is to be installed Non Ducted e Purchase a Non Ducted Kit containing one Clean Cooking Filter e Install the Clean Cooking Filter behind the aluminum mesh filter e Skip to Step 5 See page 4 for Non Ducted Kit information Non Ducted Kit available by calling Sears at 1 800 4 MY HOME DUCTED INSTALLATIONS ONLY 3 Remove appropriate Duct Knockout s from top or back of hood WIRING COVER SHIPPING TAPE TOP RECTANGULAR DUCT KNOCKOUT Remove for 314 x 10 vertical discharge REAR RECTANGULAR DUCT KNOCKOUT Remove for 314 x 10 horizontal discharge uoneledo 19 bulmues o SIJBg 8914198 DUCTED INSTALLATIONS ONLY 4 Attach 3 x 10 Damper Duct Connector over TOP BACK knockout opening Make sure damper Pivot is nearest EDGE s to Top Back Edge of hood Remove any shipping tape from damper flap 3 x 10 DAMPER DUCT CONNECTOR NON DUCTED INSTALLATIONS ONLY 5 Remove Vent Cover from the front of hood 6 Remove either top or back Wiring Knockout and install approved Electrical Cable Clamp WIRING KNOCKOUT ELECTRICAL CABLE CLAMP CONNECT THE WIRING WARNING To reduce the risk
26. t illustrated 11 SECCI N coccoconcooonnncnnaenann E CAA A A eect ati eeanes 12 Instrucciones de Seguridad oocccccococccocononnonnoccannncnanoncnnos 12 OPCION lirica 13 LINEA aii 13 Piezas incluidas con la Campana ooccccnncnnncnncnancnnnnnnnnanos 14 Piezas no incluidas con la Campana eee eee 14 Herramientas NecesarlaS cccooccnccononcnoconenoconenonenocanonocanonos 14 Cuadro de largo equivalente de conducto eeen 15 Prepare la localizaci n para la Campana 16 Prepare la campana cocncccnccnnnnnnnnnnennnnnnnnanonanononannnnos 17 18 Conecte el Cableado occoocccnccocononcnonnncnnoconononnnonononconononanos 19 stare da CAMPANA evita enews 20 Piezas de servicio it a 21 Si dentro de t a o de la fecha de la instalaci n a ne de esta campana de cocina deja de funcionar en forma apropiada debido a defecto en el material o mano de obra Sears reparar la pieza afectada o proveer e instalar una pieza nueva sin cargo GARANTIA COMPLETA DE 30 DIAS EN EL ACABADO DE PIEZAS PINTADAS O DE METAL LUSTROSO Si dentro de los 30 dias de la fecha de instalaci n el acabado de cualquier pieza pintada o de metal lustroso de esta campana de cocina presenta defecto de material o mano de obra Sears proveer e instal ra una pieza nueva sin cargo EL SERVICIO DE GARANT A SE OBTIENE PONI NDOSE EN CONTACTO CON EL CENTRO DE SERVICIO O DEPARTAMENTO SEARS MAS CERCANO EN LO
27. xtinguisher ONLY if A You know you have a Class ABC extinguisher and you already know how to operate it B The fire is small and contained in the area where it started C The fire department is being called D You can fight the fire with your back to an exit Based on Kitchen Firesafety Tips published by NFPA CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 3 For best capture of cooking impurities your range hood should be mounted so that the top of the hood is 24 30 above the cooking surface 4 Use only with range hood cord connection kits that have been investigated and found acceptable for use with this model range hood 5 Please read specification label on product for further information and requirements If hood is to be installed Non Ducted se Purchase a non ducted filter from your local distributor or retailer and install it beneath the aluminum mesh filter FAN LIGHT Fan The fan switch is a solid state speed control Rotate the switch clockwise to turn the fan ON to HIGH speed Continue rotat ing the switch clockwise to reduce the fan speed Light The light switch has 3 positions The light is OFF when the switch is rotated fully counterclockwise Rotate the switch clo