Home
JVC WB-1540U User's Manual
Contents
1. connection cover and fasten the 4 screws M3 x 12 removed in step 4 using the provided hexagon wrench 14 Others Specifications WB 1540U E General E Mass 5 0 kg Power Voltage AC 24 V 50 Hz 60 Hz Main Housing Unit E Accessories Power Consumption INStrUCTIONS eeeeeeeeeeeeeeeeeeee 1 25 W During heater operation excluding Bsr e e 11 Coe ee ee 1 camera Screw M4X20 suasanana 4 Installation Location Hexagon wrench 1 Outdoor general Ambient Temperature 20 C to 50 C when equipped with TK C625U E 20 C to 40 C when equipped with VN C625U Heater Operation Temperature Internal temperature Heater turns ON between 8 C 5 C Turns OFF between 20 C 5 C Ambient Humidity 35 to 90 Vibration Shock Locations without vibration shock Dustproof Waterproof IP66 x When combined with compatible camera Permissible Wind Speed 40 m s or below E Compatible Cameras TK C625U E VN C625U E Dimensional Outline Drawing Unit mm 294 x Specifications and appearance of this unit as well as related products may be modified for improvement without prior notice E General Power Voltage AC 24 V 50 Hz 60 Hz Main Housing Unit Power Consumption 25 W During heater operating excluding camera Installation Location Outdoor general Ambient Temperature 20 C to
2. OUTDOOR HOUSING WB 1540U WB 1550U INSTRUCTIONS B wB 1550U only For Customer Use Enter below the Serial No which is located on the body Retain this information for future reference Model No WB 1540U WB 1550U Serial No LST0267 001C These are general IMPORTANT SAFEGUARDS and certain items may not apply to all appliances IMPORTANT SAFEGUARDS OJ AUN 10 11 12 13 14 15 16 17 18 Slots and openings in the cabinet and the back or bottom are provided for ventilation and to insure reliable operation Read all of these instructions Save these instructions for later use All warnings on the product and in the operating instructions should be adhered to Unplug this appliance system from the wall outlet before cleaning Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning Do not use attachments not recommended by the appliance manufacturer as they may cause hazards Do not use this appliance near water for example near a bathtub washbowl kitchen sink or laundry tub in a wet basement or near a swimming pool etc Do not place this appliance on an unstable cart stand or table The appliance may fall causing serious injury to a PORTABLE CART WARNING child or adult and serious damage to the appliance may fall causing serious injury to a child or adult and serious symbol provided By RETAC damage to the appliance Use only with a ca
3. Pay attention when handling the desiccant in order to maintain its effectiveness Do not remove it from the bag until you are about to use it e Do not wet it or touch it with wet hands e Assemble promptly upon adhering the desiccant e Be sure to replace the desiccant during maintenance 2 Mount the lower housing Mount the lower housing that is dismantled in Step 2 t pg 10 to the main housing unit using the 3 Screws A M4 x 6 Do so by aligning the position marks of the lower housing and the main housing unit 3 Mount the gasket and gasket gland Mount the gasket and gasket gland that are dismantled in Step 7 pg 10 of the housing disassembly procedure to the lower housing using the 6 Screws B M4 Screw B M4 x6 CAUTION During assembly ensure that wires and cables are not caught in the housing Do not exert force unnecessarily on the gasket or twist it during mounting e Check to ensure that the gasket is in close contact with the camera Mounting the Housing to the wall 1 Drill a hole into the wall ie ae and above Drill a hole 45 mm for inserting the connection cable Refer to left fig Washer 2 Affix anchor bolts onto the wall e Affix 4 anchor bolts M8 35 mm and above for attaching the housing Refer to left fig Affix an anchor bolts for attaching the safety wire in the middle about 60 mm from both ends of the 2 upper anchor bolts 30 mm fr
4. falls it may cause injury or accidents W Taking vibrations mass and wind force into account ensure to mount in a location with sufficient strength using solid anchor bolts If reinforced or spiral nuts are not tightened enough picture blurring may occur on the monitor screen due to vibration and in the worst case there is a danger of falling W Use at the voltage indicated A voltage other than that displayed may result in fire or electric shocks W This unit supports lightning conduction to the connection cable to some extent but not fully At installation locations where there may be a lightning hazard be sure to add an arrester to the connection cable or take other precautions WE Do not dangle shake or hook objects If too much load is placed on top it may fall and cause injury or accidents W If a ball or bird hits this unit bringing about some sort of trouble consult your dealer or the nearest Victor service center WE Do not modify this unit yourself Accidents may result W Do not install in locations where there may be vibrations or impact If it falls it may Cause injury or accidents W Regularly check for the deterioration of attaching parts and the loosening of the screws caused by vibrations If it falls it may Cause injury or accidents W Do not install in locations where radiation X rays or corrosive gases are emitted Doing so may cause the camera to malfunction WE Keep all packaging out of the
5. Screw M4 x 4 2 Screw M3 x 2 Preparation Converter Unit 3 X Mounting Bracket 7 Dismantle the camera mounting bracket Loosen the screws on the camera mounting bracket M4 4 pcs using a driver to dismantle it 2 Dismantle the converter unit mounting bracket Loosen the screws on the converter unit mounting bracket M3 2 pcs using a driver to dismantle it 3 Mount the converter unit to the housing Clamp the converter unit using the converter unit mounting bracket followed by mounting it to the housing using the screws M3 2 pcs removed in Step 2 When mounting pay attention to the orientation of the converter unit as shown in the left diagram 4 Mount the camera mounting bracket Mount the camera mounting bracket dismantled in step 1 to the housing Mount it exactly to the original position Mounting Before mounting Remove the ceiling mount cover of the camera and guide the cables supplied with WB 1550U through the cover x For further details please refer to the instruction manual of To POWER INPUT DC 18 V the camera in use Terminal of Ceiling Mount Camera Mounting Bracket Connector 7 Connect the AC 24 V output cable to the converter unit Follow the procedures below to connect the AC 24 V output cable of the main board on the main housing unit to the converter unit 4 Push both ends of the connector as shown in the left diagram to remove it from the supplied
6. reach of children If used for play it may cause injury or suffocation W This installation should be made by a qualified service person and should conform to all local codes and the National Electrical Code ANSI NFPA 70 System Example VN C625U and VN C655U Systems WB 1540U WB 1550U Power Cable DC 12V Power Cable Not in use on this system 1 AC 24V mp AC 24 V Power Supply x Coaxial Cable E Monitor WB 1540U WB 1550 U Main Board Alarm Cable a 5 p z m Alarm Device Bi TQ lt LAN Cable L Connected fo v O TO CAMERA Fuse x To VIDEO OUT Terminal To ALARM IN OUT Terminal Power Indicator Red light turns on during power supply VN C625U 655U Supplied Converter Unit To POWER INPUT DC 18 V _ _ _ To 10 BASE T 100 BASE TX Terminal Terminal VN C655U To POWER INPUT DC 12 V CTD Ceiling Mount of Network Camera Terminal VN C625U CAUTION x1 Not in use on this system Ensure to bind both ends of cables that are not in use with insulating tape x2 Power will not be supplied to this unit and the installed camera when the fuse on the main board burns out When this occurs please consult your nearby JVC dealer as exchange of fuse according to the rating 125 V 5 A will be required TK C625U E TK C655E and TK C676E Systems WB 1540U WB 1550U Power Cable DC 12 V Not in use on this system 1 LAN
7. 50 C when equipped with TK C676E TK C655E 20 C to 40 C when equipped with VN C655U Heater Operation Temperature Internal temperature Heater turns ON between 8 C 5 C Turns OFF between 20 C 5 C Ambient Humidity 35 to 90 Vibration Shock Locations without vibration shock Dustproof Waterproof IP66 x When combined with compatible camera Permissible Wind Speed 40 m s or below E Mass 5 0 kg E Accessories INSTFUCTIONS ccecceeeeeeeeeeeeees 1 DIOSICCANM ecwatsarersntiwonesedeacenrendeess 1 Screw M4x20 cccceessseeeees 4 Hexagon wren ch 0ee 1 E Compatible Cameras TK C676E TK C655E VN C655U E Dimensional Outline Drawing Unit mm 294 A 152 Xs 260 Hat x Specifications and appearance of this unit as well as related products may be modified for improvement without prior notice 15 2007 Victor Company of Japan Limited LST0267 001C ONISNOH HOOGLNO NOSSL GM NOVSL GM
8. Cable Power Cable AG 24 V ower Cable To Insulated AC 24 V Power Supply Coaxial Cable ml B VIDEO INPUT Communication Cable TO CAMERA B 8888 aoe WB 1540U WB 1550U Main Board LED RM P2580U E 1 AC24V INPUT TB TO CAMERA Power Indicator Red light turns on during power supply Fuse To VIDEO OUT TO CCU Terminal To POWER INPUT AC 24 V Terminal _ ___ To CONTROL ALARM IN OUT Terminal Ceiling Mount of Combination Camera CAUTION Ensure to turn of the power of devices in use before connecting Refer to the instruction manual for the combination camera that is supplied with this unit as well during connection and installation x1 Not in use on this system Ensure to bind both ends of cables that are not in use with insulating tape x2 Power will not be supplied to this unit and the installed camera when the fuse on the main board burns out When this occurs please consult your nearby JVC dealer as exchange of fuse according to the rating 125 V 5 A will be required Installation and Connection WB 1540U Disassembling the Housing gt A M4 x6 x3 Lower Housing Safety Wire l P Gasket 1 LQ D Gasket Gland a ie lt 5 Screw B M4 x 6 7 Dismantle the gasket and gasket gland Loosen the 6 Screws B M4 using a driver followed by dismantling the gasket and gasket gla
9. assembly ensure that wires and cables are not caught in the housing e Do not exert force unnecessarily on the gasket or twist it during mounting Check to ensure that the gasket is in close contact with the camera Lower Housing Position Mark Gasket Gland Mounting the Housing to the wall 1 Drill a hole into the wall eee and above Drill a hole 45 mm for inserting the connection cable Refer to left fig Washer 2 Affix anchor bolts onto the wall e Affix 4 anchor bolts M8 35 mm and above for attaching the housing Refer to left fig Affix an anchor bolt for attaching the safety wire in the middle about 60 mm from both ends of the 2 upper anchor bolts 30 mm from the top Refer to left fig 3 Mount the safety wire and arm to the wall e Mount the safety wire attached to the housing to the anchor bolts using the nut and wire Use the nut and wire to mount the housing onto the wall Safety Wire 13 Installation and Connection WB 1550U Mounting the Housing to the Wall continued 4 Open the cable connection cover Use provided hexagon wrench to remove the 4 screws M3 x 12 from the cable connection cover to open it 5 Connect each cable Connect the necessary cables CAUTION Ensure to bind connectors of LAN cables that are not in use with an insulating tape before use Ensure to bind the DC 12 V Power Cable that is not in use on this
10. converter unit 2 Cut the Y terminal of the AC 24 V output cable and peel off about 5 mm of the coating 3 Push the arrow mark using tools such as a flat head screwdriver to insert the coating of the AC 24 V output cable into the connector 4 Attach the connector to the converter unit 2 Mount the Y terminal of the converter unit to the Connect to AC 24 V Output Cable AC 24 V Output Cable f Main Board TT a Aare D To POWER ceiling mount of VN C655U N DC Guide the Y terminal of the converter unit through the AE Terminal of ceiling mount cover followed by connecting it to the g g Ceiling Mount POWER INPUT DC 18 V terminal of VN C655U s ceiling mount 3 Connect other cables Connect the necessary cables supplied with the housing coaxial video cable alarm signal cable LAN cable etc to the corresponding terminals on the ceiling mount CAUTION Connect the communication cable to the alarm terminal if necessary In addition DC 12 V Power Cable is not in use Main Board on this system For safety reasons ensure to cut off any Safety OY ast f ON excess cable and bind using an insulating tape before use ee A Mark e For further details on connection please refer to the Cables D instruction manual of the camera in use 3 8 8 amp Ceiling Mount 4m leon n agen nee Mount the camera s ceiling mount to the main t Screws Supplied 4 pcs ho
11. e abused by persons walking on it Follow all warnings and instructions marked on the appliance Do not overload wall outlets and extension cords as this can result in fire or electric shock Never push objects of any kind into his appliance through cabinet slots as they mat touch dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the appliance Do not attempt to service this appliance yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel Unplug his appliance from the wall outlet and refer servicing to qualified service personnel under following conditions a When the power cord or plug is damaged or frayed b If liquid has been spilled into the appliance c If the appliance has been exposed to rain or water d If the appliance does not operate normally by following the operating instructions Adjust only those controls that are covered by the operating instructions as improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the appliance to normal operation e If the appliance has been dropped or the cabinet has been damaged f When the appliance exhibits a distinct change in performance this indicates a need for service When replacement parts are required be sure the service technician has used r
12. eidicted cabeeted 11 TK C655E a d TK GO70E ririri i aa 11 VN CO55U irnn na a 12 Assembling the Housing ssssssssseesenssssrnrresrrrrensrrrrrerrrrreeen 13 Mounting the Housing to the wall sssseessessesseseerresrrreesen 13 Others Specifications oier iera esac e Reese 15 WB 1540U sccciastecteccaghtdsaicdcnassiaaceaanicsatatinarbsaaetaemeaaqnesceees 15 WB 15500 urnana a t 15 Operating Precautions Mi Depending on the installation environment of this unit the life span of the attached camera may decrease significantly Give close attention to the installation location especially if used continuously under high temperature or in locations constantly exposed to direct sunlight W As the interior of this unit will heat up be sure to use San Disk industrial if loading the CF card to VN C625U W This unit may stop functioning properly due to natural hazards as it is to be installed outdoors To take photographs properly be sure to perform daily checks W Do not install this unit in locations with sharp temperature changes such as near air con compressors or exhaust pipes Condensation may occur inside the attached combination camera W To save energy switch off the system when not in use Mi For safety reasons special techniques are necessary for installation Consult your dealer regarding installation and ensure that it is carried out by a specialist Mi Be sure to mount the safety wire for safety purposes If it
13. eplacement parts specified by the manufacturer that have the same characteristics as the original part Unauthorized substitutions may result in fire electric shock or other hazards Upon completion of any service or repairs to this appliance ask the service technician to perform routine safety checks to determine that the appliance is in safe operating condition For USA and CANADA CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance INFORMATION FOR USA E INFORMATION This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and
14. he left diagram 7 Failure to do so may cause malfunctions due to penetration of rain water vi Bind using a waterproof adhesive tape 6 8 Cover the hole and the mounting side of 7 housing with waterproof seal Not in use on this system After the cables have been connected cover the holes made in step 7 with waterproof seal With the Cable connection cover open put your hand in and cover the hole Cover the mounting side of the housing with waterproof seal NOTE Be sure to perform waterproofing Seepage of rainwater may result in malfunction Use GE silicon or its equivalents as the sealing material 9 Close the cable connection cover When cable connection is complete close the cable connection cover and fasten 4 screws M3 x 12 removed in step 4 using the provided hexagon wrench Installation and Connection WB 1550U Disassembling the Housing Main Housing Unit Screw A M4 x 6 x3 ma JVC S z S oo Lower Housing Safety Wire e id oN _ tt Gasket Ete pe 1 L O Gasket Gland Screw B M4 x 8 7 Dismantle the gasket and gasket gland Loosen the 8 Screws B M4 using a driver followed by dismantling the gasket and gasket gland from the lower housing x The 8 Screws B M4 cannot be totally removed from the gasket to prevent it from falling off 2 Dismantle the lower housing Loosen the 3 Screws A M4 x 6 using a driver follo
15. if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help E CAUTION CHANGES OR MODIFICATIONS NOT APPROVED BY JVC COULD VOID USER S AUTHORITY TO OPERATE THE EQUIPMENT THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND 2 THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION INFORMATION FOR CANADA RENSEIGNEMENT POUR LE CANADA This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme a la norme NMB 003 du Canada Due to design modification data given in this instruction book are subject to possible change without prior no
16. le to the ceiling mount of JVC Mark Notch the camera to be installed 2 Connect other cables Connect the coaxial video cable and communication cables alarm signal control terminal etc supplied with the housing to the ceiling mount CAUTION Connect the communication cable to the ALARM IN OUT and CONTROL terminals if necessary For safety reasons ensure to cut off any excess cable and bind using an insulating tape before use For further details on connection please refer to the instruction manual of the camera in use Ensure to bind connectors of LAN cables and DC 12 V Power Cable that are not in use with an insulating tape Interior of Housing Safety Wire ate Board D gt m Jve before use ain Boar f z 5 eS A 3 babar the eum of the camera to the N main housing unl Cables 7 Use the 4 screws supplied to mount the ceiling mount to 2 a Rouen i LS OSL the main housing unit T Sy A Mark sale bs ean CAUTION A i 6 4 set During mounting align the A mark of the ceiling mount with P e oun e Ree N Screws Supplied ao on the camera mount bracket of the main housing 4 pcs unit N 4 Mount the camera to the ceiling mount 4 Follow instructions in the manual of the camera to be installed to mount the camera to the ceiling mount To POWER INPUT AC 24 V Terminal of Ceiling Mount CP Camera Installation and Connection WB 1550U Mounting the Camera VN C655U 1
17. nd from the lower housing x The 6 Screws B M4 cannot be totally removed from the gasket to prevent it from falling off 2 Dismantle the lower housing Loosen the 3 Screws A M4 x 6 using a driver followed by dismantling the lower housing from the main housing unit x The lower housing is connected to the main housing unit using a safety wire CAUTION Pay careful attention to store the dismantled parts and screws until assembly is complete to prevent them from being misplaced Mounting the Camera TK C625U E Interior of Housing Safety Wire Main Board Cables Cover IN 4t FRONT P Sahat 2 Mark EG F To POWER INPUT AC 24 V Terminal of Ceiling Mount Screws Supplied M4 x 20 x 4 4 Camera Before mounting Remove the ceiling mount cover of the camera and guide the cables supplied with WB 1540U through the cover x For further details please refer to the instruction manual of the camera in use 7 Connect the AC 24 V output cable to the camera Connect the AC 24 V output cable of the main board to the camera s ceiling mount bracket 2 Connect other cables Connect the necessary cables supplied with the housing coaxial video cable communication cable etc to the ceiling mount CAUTION Connect the communication cable to the ALARM IN OUT and CONTROL terminals if necessary For safety reasons ensure to cut off any excess cable and bind using an i
18. nsulating tape before use For further details on connection please refer to the instruction manual of the camera in use Ensure to bind connectors of LAN cables and DC 12 V Power Cable that are not in use with an insulating tape before use 3 Mount the camera s ceiling mount to the main housing unit Use the 4 screws supplied M4 x 20 to mount the ceiling mount to the main housing unit NOTE During mounting align the t FRONT Mark of the ceiling mount with the notch on the camera mount bracket of the main housing unit 4 Mount the camera to the ceiling mount Follow instructions in the manual of the camera in use to mount the camera to the ceiling mount Mounting the Camera VN C625U Screw M4 x 4 2 Screw M3 x 2 a j Converter Unit i Mounting Bracket Camera IGE Mounting ra Bracket Connector Connector To POWER INPUT DC 12 V Terminal of Ceiling Mount S Main Board AC 24V Output Cable eae eee 2 To POWER INPUT DC aa 12 V gi gt Terminal of E Connector rs Ceiling XG Interior of Housing Mount Wve lt q Main Board Safety Wire To 4 E a Screws Supplied M4 x 20 x 4 Ceiling Mount Camera Preparation 7 Dismantle the camera mounting bracket Loosen the screws on the camera mounting bracket M4 4 pcs using a driver to dismantle it 2 Dismantle the conver
19. om the top Refer to left fig 3 Mount the safety wire and arm to the wall e Mount the safety wire attached to the housing to the anchor bolts using the nut and wire Use the nut and wire to mount the housing onto the wall Mounting the Housing to the Wall continued 4 Open the cable connection cover Use provided hexagon wrench to remove the 4 screws M3 x 12 from the cable connection cover to open it 5 Connect each cable Connect the necessary cables NOTES When connecting to TK C625U E ensure to bind connectors of LAN cables that are not in use with an insulating tape before using e Ensure to bind the DC 12 V Power Cable that is not in use on this system with insulating tape 8 4 Screw M3 x 12 x 6 Bind cable using a waterproof tape Upon connecting ensure to perform waterproofing procedures by binding the joint of each cable with a waterproof adhesive tape CAUTION For safety reasons turn on the power only upon connecting all cables Alarm Communication Cable LAN Cable Male Coaxial Video Cable AC 24V X DC 12 V Power Cable Power Cable Fasten the cables in the interior of the arm When waterproofing is complete insert the cables into the 8 VLA upper interior of the arm and fasten using a tape CAUTION When inserting the cables ensure that all cable connections are above the cable connection cover see dotted line in t
20. rt or stand recommended by the manufacturer or sold with the appliance Wall or shelf mounting should follow the manufacturer s instructions and should use a mounting kit approved by the manufacturer An appliance and cart combination should be moved with care Quick stops excessive force and uneven surfaces may cause the appliance and cart combination to overturn of the appliance and to protect it from overheating these openings must not be blocked or covered The openings should never be blocked by placing the appliance on a bed sofa rug or other similar surface This appliance should S3125A never be placed near or over a radiator or heat register This appliance should not be placed in a built in installation such as a bookcase unless proper ventilation is provided This appliance should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power supplied to your home consult your dealer or local power company For appliance designed to operate from battery power refer to the operating instructions For added protection for this product during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the antenna or cable system This will prevent damage to the product due to lightning and power line surges Do not allow anything to rest on the power cord Do not locate this appliance where the cord will b
21. system with insulating tape 6 Bind cable using a waterproof tape Upon connecting ensure to perform waterproofing procedures by binding the joint of each cable with a waterproof adhesive tape CAUTION For safety reasons turn on the power only upon connecting all cables Alarm Communication Cable Coaxial Video Cable LAN Cable Male AC 24 V X DC 12 V Power Cable Power Cable Fasten the cables in the interior of the arm 8 ped When waterproofing is complete insert the cables into the Hole n Sy upper interior of the arm and fasten using a tape Waterproofing sient CROTON When inserting the cables ensure that all cable connections are above the cable connection cover see dotted line in the left diagram Failure to do so may cause malfunctions due to penetration of rain water vi Bind using a waterproof adhesive tape 6 eel aoe a ils eyeiom 8 Cover the hole and the mounting side of housing with waterproof seal After the cables have been connected cover the holes made in step 7 with waterproof seal With the Cable connection cover open put your hand in and cover the hole Cover the mounting side of the housing with waterproof seal NOTE Be sure to perform waterproofing Seepage of rainwater may result in malfunction Use GE silicon or its equivalents as the sealing material 9 Close the cable connection cover When cable connection is complete close the cable
22. ter unit mounting bracket Loosen the screws on the converter unit mounting bracket M3 2 pcs using a driver to dismantle it 3 Mount the converter unit to the housing Clamp the converter unit using the converter unit mounting bracket followed by mounting it to the housing using the screws M3 2 pcs removed in Step 2 When mounting pay attention to the orientation of the converter unit as shown in the left diagram 4 Mount the camera mounting bracket Mount the camera mounting bracket dismantled in step 7 to the housing Mount it exactly to the original position Before mounting Remove the ceiling mount cover of the camera and guide the cables supplied with WB 1540U through the cover x For further details please refer to the instruction manual of the camera in use 7 Connect the AC 24 V output cable to the converter unit Follow the procedures below to connect the AC 24 V output cable of the main board on the main housing unit to the converter unit 4 Push both ends of the connector as shown in the left diagram to remove it from the supplied converter unit 2 Cut the Y terminal of the AC 24 V output cable and peel off about 5 mm of the coating 3 Push the arrow mark using tools such as a flat head screwdriver to insert the coating of the AC 24 V output cable into the connector 4 Attach the connector to the converter unit 2 Mount the Y terminal of the converter unit to the ceiling mount of VN C625U Guide
23. the Y terminal of the converter unit through the ceiling mount cover followed by connecting it to the POWER INPUT DC 12 V terminal of VN C625U s ceiling mount 3 Connect other cables Connect the necessary cables supplied with the housing coaxial video cable alarm signal cable LAN cable etc to the corresponding terminals on the ceiling mount CAUTION Connect the communication cable to the alarm terminal if necessary In addition DC 12 V Power Cable is not in use on this system For safety reasons ensure to cut off any excess cable and bind using an insulating tape before use For further details on connection please refer to the instruction manual of the camera in use 4 Mount the camera s ceiling mount to the main housing unit Use the 4 screws supplied M4 x 20 to mount the ceiling mount to the main housing unit NOTE During mounting align the t FRONT mark of the ceiling mount with the notch on the camera mount bracket of the main housing unit 5 Mount the camera to the ceiling mount Follow instructions in the manual of the camera in use to mount the camera to the ceiling mount Installation and Connection WB 1540U Assembling the Housing 1 Adhering the desiccant Use a tape to adhere the supplied desiccant to the interior of the lower housing CAUTION Fogging may occur when there are drastic temperature changes In this case continue using without turning off the power
24. tice Getting Started Thank you for purchasing this product These instructions are for WB 1540U WB 1550U Before beginning to operate this unit please read the instruction manual careully in order to make sure that the best possible performance is obtained The compatible cameras for each housing are as follows e WB 1540U TK C625U E VN C625U e WB 1550U TK C676E TK C655E VN C655U Table of Contents Getting Started TADEO COMNEN S ereire esi a eae seen avec aa ie 4 Operating Precautions svsez vecssnisacenectestesceenisecesnaettactaveeuseuentes 4 DV SIC EXa Mpe mosen eles aa caters i 5 VN C625U and VN C655U Systems cccceeseeeeeeeeeeees 5 TK C625U E TK C655E and TK C676E Systems 5 Installation and Connection WB 1540U Disassembling the HOUSING ccceceesseeeeceeneeeeeenanereeeeeaes 6 Mounting the Camera cc ceececceeceeeeseeeeeeceeeeneeeeeeeeeeeaaseeeees 6 TKR CG2Z5U E inorena ine cel eeiiein eane ted NSS 6 VINSG625U 5 dacantadgenasaeuedeateasncenaetantaneanaccotandecnnadsamsteeetnares 7 Assembling the HOUSING c cccccseesereceeeseeeeeeseeeeenenseeeenes 8 Mounting the Housing to the wall ccceeeeeeeeeeeeeeeeeeee eee 8 Installation and Connection WB 1550U Disassembling the HOUSING cceeeeeeeeeeeeeeeeeeeeeeeeeeeeeaaees 10 Procedures Before Mounting the Camera ceee 10 Mounting the CAMera ce cccciicietiveolteeclneteveentie
25. using unit VA N Use the screws supplied 4 pcs to mount the ceiling 4 5 mount to the main housing unit NOTE D camera During mounting align the A mark of the ceiling mount with the notch on the camera mount bracket of the main housing unit 5 Mount the camera to the ceiling mount Follow instructions in the manual of the camera in use to mount the camera to the ceiling mount 12 Assembling the Housing 7 Mount the desiccant Use a tape to adhere the supplied desiccant to the interior of the lower housing CAUTION Fogging may occur when there are drastic temperature changes In this case continue using without turning off the power Pay attention when handling the desiccant in order to maintain its effectiveness e Do not remove it from the bag until you are about to use it Do not wet it or touch it with wet hands Assemble promptly upon adhering the desiccant Be sure to replace the desiccant during maintenance 2 Mount the lower housing Mount the lower housing that is dismantled in Step 2 t pg 10 to the main housing unit using the 3 Screw A M4 x 6 Do so by aligning the position marks of the lower housing Gasket and the main housing unit 3 Mount the gasket and gasket gland Mount the gasket and gasket gland that are dismantled in Step 7 pg 10 of the housing disassembly procedure to the lower housing using the 8 Screws B M4 CAUTION Screw B M4 x 8 During
26. wed by dismantling the lower housing from the main housing unit x The lower housing is connected to the main housing unit using a safety wire Camera Body Cover Dome Cover Rubber ___ Rubber Gasket Gasket WUT IE uum Se 10 7 Dismantle the rubber gasket of the camera s ceiling mount Dismantle the rubber gasket white on the same side as the ceiling mount of the combination camera to be installed 2 Dismantle the rubber gasket in the interior of the camera Follow the procedures below to remove the rubber gasket from the interior of the combination camera 1 Turn the camera body cover in the direction as indicated in the left diagram When the camera body cover is tight and cannot be turned do so upon fastening the main unit 2 Dismantle the camera body cover 3 Dismantle the dome cover 4 Remove the rubber gasket and restore the dome cover and camera body cover to their original positions CAUTION The combination camera is an enclosed unit In order to prevent fogging in the interior of the dome cover ensure to remove the rubber gasket 2 types before use e Do not remove the combination camera from the housing and use it singly after removing the rubber gasket and installing to the housing Doing so may cause the camera to malfunction Mounting the Camera TK C655E and TK C676E 7 Connect the AC 24 V output cable to the camera Connect the AC 24 V output cab