Home

Hunter 43041-01 User's Manual

image

Contents

1. Turn on the power source Test the motor If the motor does not run check the plug connection 43041 01 01 31 2008 Go to step E on page 18 to attach grille Existing Construction accessible only from below EXISTING FAN Remove an existing fan and check to make sure the opening Move the housing into position above the ceiling is large enough to accommodate the new motor housing 8 x Pull wires through strain relief Attach existing ducting to duct connector Tape joints ducting does not fit securely an adapter may need to be purchased 43041 01 01 31 2008 Install the housing flush with the sheetrock and secure by tight ening the pre loaded screws into the joist Black Switch 2 AC In Connect wires as shown Install the wiring cover plate Connect wiring from the motor to the wiring cover plate 43041 01 01 31 2008 Reinstall the motor by inserting the tabs and pushing up into Secure the motor by tightening the 2 screws position Make sure the wires are not pinched between the mo tor and the housing ON OFF Turn on the power source Test the motor If the motor does not run check the plug con nection Go to step Er on page 18 to attach grille 43041 01 01 31 2008 Remove the str
2. Desserrer les vis EL Retirer le moteur souffleur du bo tier Retirer les capuchons du bout des vis pr install es D visser les vis pr install es jusqu a ce que leur bout affleure le c t du bo tier 43041 01 01 31 2008 D foncer le premi re pastille d acc s Introduire le raccord non compris dans le bo tier En utiliser une seconde si n cessaire et le fixer avec une rondelle Choisir votre option d installation Pour une nouvelle construction Fixation une solive aller l tape A11 page 50 Pour une nouvelle construction Fixation entre des solives aller l tape B11 page 52 Pour une construction existante accessible du dessus aller l tape C11 page 55 Pour une construction existante accessible uniquement du dessous aller l tape D11 page page 59 43041 01 01 31 2008 Nouvelle construction Fixation a une solive Placer la bonne marque de hauteur sur le bord inf rieur de la Visser les vis pr install es dans la solive ou la structure solive selon l paisseur de votre plaque de gypse Passer les fils par le raccord Prise de terre du ventilateur Lumi re O Noir Interrupteur principal 2 entree CA Connecter les fils tel qu indiqu 43041 01 01 31 2008 NA Installer la plaque de couvercle du c blage Assurez vous que Raccorder la gaine de 4 po et l vent l ext rieur Jointer avec t
3. 7 a O Negro Interruptor 2 CA Conecte los alambres como se muestra Instale la placa de cubierta del cableado Aseg rese que todas Conecte el mazo de cables NO PERMITA QUE EL MOTOR las conexiones de cableado est n dentro de la caja o debajo SOPLADOR CUELGUE DEL MAZO DE CABLES de la placa de cubierta del cableado EJ 38 43041 01 01 31 2008 2 E ap Y D A da CA Vuelva a instalar el motor soplador introduciendo las pesta as Asegure el motor soplador apretando los 2 tornillos y levantando a su posici n Aseg rese que los alambres no se pellizquen entre el motor soplador y el alojamiento Encienda la fuente de alimentaci n Pruebe el motor soplador Si el motor soplador no funciona verifique la conexi n del enchufe Vaya al paso en la p gina 40 para fijar la rejilla 43041 01 01 31 2008 Retire los tornillos de mano Conecte el mazo de cables NO PERMITA QUE EL ARTEFAC TO DE ILUMINACION CUELGUE DEL MAZO DE CABLES Retire el tornillo del soporte del aliviador de tensiones Coloque el soporte del aliviador de tensiones 3 debajo del motor como se muestra Introduzca la pesta a en ngulo del soporte del aliviador de Alinee los postes A B C y D estampados en la caja del mo tensiones para que se engan
4. bath exhaust fan IF THE ORIGINAL USER OR CONSUMER PURCHASER CEASES TO OWN THE FAN THIS WARRANTY AND ANY IMPLIED WARRANTY WHICH THEN REMAINS IN EFFECT INCLUDING BUT NOT LIMITED TO ANY IM PLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE VOIDED NO WARRANTY EXPRESS OR IMPLIED INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IS MADE IN RESPECT OF GLASS FIXTURES OR LIGHT BULBS OR THE FINISH ON ANY METAL PORTION OF THE BATH EXHAUST FAN THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES THE DURATION OF ANY IMPLIED WARRANTY INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FIT NESS FOR A PARTICULAR PURPOSE IN RESPECT TO ANY HUNTER FAN BATH EXHAUST FAN MOTOR OR OTHER FAN PART IS EXPRESSLY LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY SET FORTH ABOVE FOR SUCH MOTORS OR OTHER PARTS This warranty is voided if your Hunter bath exhaust fan is not purchased and installed in the U S A This warranty excludes and does not cover defects malfunctions or failures of any Hunter bath exhaust fan which were caused by repairs by persons not authorized by us use of parts or accessories not authorized by us mishandling improper installation modifications or damage to the Hunter bath exhaust fan while in your possession or unreasonable use including failure to provide reasonable and necessary maintenance To obtain servicing contact the nearest Hunter authorized service c
5. bonne marque de profondeur sur le bord inf rieur de Marquer la position des vis en vous servant des trous comme la solive selon l paisseur de votre plaque de gypse gabarit Percer un trou au centre de chaque trait Ins rer les vis en laissant un espace entre la t te de la vis et la solive Les vis ne sont pas fournies Fixer les glissi res sur les vis Visser les vis 43041 01 01 31 2008 Raccorder la gaine de 4 po et l vent a l ext rieur Jointer avec Passer les fils par le raccord du ruban Si la gaine n est pas de la bonne dimension vous pourriez devoir acheter un adaptateur Serrer les vis du raccord Prise de terre CS S N Cuivre nu Moteur X du ventilateur Ay Lumi re O Noir Interrupteur principal 2 entree CA Connecter les fils tel qu indiqu 43041 01 01 31 2008 Installer la plaque de couvercle du cablage Assurez vous que Connecter le cablage NE LAISSER PAS LE MOTEUR toutes les connexions de cablage sont dans la boite ou der SOUFLEUR PENDRE PAR LE CABLAGE ri re la plaque de couvercle du cablage Reposer le moteur souffleur en ins rant les languettes et en le Fixer le moteur souffleur en serrant les deux vis poussant vers le haut en place Assurez vous que les fils n ont pas t pinc s entre le moteur souffleur et le boitier Remettre le courant Essayer le moteur souffleur Si
6. de moteur souffleur tout en poussant vers l ext rieur le c t du bo tier ou ins rer un tournevis dans la fente du boi tier pr s de la languette et faire levier Passer doucement l aspirateur sur le ventilateur le moteur souffleur et l int rieur du bo tier IL NE FAUT JAMAIS IMMERGER DANS L EAU LES PI CES M TALLIQUES ET LECTRIQUES ENTRETIEN Roc Plancher Le moteur souffleur est lubrifi en permanence et n a jamais besoin d huile Si cuisson les paliers du moteur souffleur font un bruit excessif ou inhabituel remplacer le moteur souffleur avec exactement le m me moteur souffleur Vous devriez en m me temps remplacer la turbine 43041 01 01 31 2008 sy 3 sy 45 45 a FS fo Y V rifier toutes les pi ces Si certaines sont endommag es appeler le 1 866 405 3814 3 de eee pour des pi ces de rechange eee oe ees gt 95044 01 000 gt 95029 01 000 gt 75191 01 000 03242 07 133 98037 01 000 74508 03 133 77521 01 000 gt gt gt gt 65219 01 000 gt gt gt 97956 01 000 75184 01 133 97958 01 000 77537 01 000 Inclus Outils n cessaires Non fournis Temps estim du montage De 30 60 minutes 43041 01 01 31 2008 Avant l installation NOTE Enlevez tous les mat riaux d emballage avant installation
7. del manguito de alivio de tension Blanco Cobre desnudo Motor del Negro Interruptor principal 1 CA ventilador Blanco Negro Interruptor 2 CA Conecte los alambres como se muestra 43041 01 01 31 2008 NA Instale la placa de cubierta del cableado Aseg rese que Conecte un ducto de 4 y ventile hacia el exterior Aplique todas las conexiones de cableado est n dentro de la caja o cinta a las uniones Si el ducto no se ajusta firmemente debajo de la placa de cubierta del cableado puede ser necesario comprar un adaptador Conecte el mazo de cables NO PERMITA QUE EL MOTOR Vuelva a instalar el motor soplador introduciendo las pesta as SOPLADOR CUELGUE DEL MAZO DE CABLES y levantando a su posici n Aseg rese que los alambres no se pellizquen entre el motor soplador y el alojamiento Asegure el motor soplador apretando los 2 tornillos Encienda la fuente de alimentaci n 43041 01 01 31 2008 Vaya al paso E en la p gina 40 para fijar la rejilla Pruebe el motor soplador Si el motor soplador no funciona verifique la conexi n del enchufe Deslice los rieles de montaje en los soportes Ubique la correcta marca de profundidad en el borde inferior de la viga seg n el espesor de su plancha de yeso Marque la posici n de los tornillos utilizando los agujeros Marque la posici n de los tornillos utili
8. des pi ces en verre et des ampou les fait d faut durant l ann e suivant la date de l achat cause d un d faut de mat riel ou de main d uvre nous r parerons ou remplacerons notre choix la pi ce d fectueuse sans frais de pi ces ou de main d uvre notre plus proche centre de service ou notre atelier de service de Memphis au Tennessee Apr s cette p riode d un an vous serez responsable pour tous les frais de pi ces et de main d uvre pour les r parations du ventilateur de salle de bain l exception des r parations au moteur telles qu offertes ci dessous Si votre moteur de ventilateur de salle de bain tombe en panne durant les cinq ans suivant la date de votre achat cause d un d faut de mat riel ou de main d uvre nous vous offrirons sans frais le travail et les mat riaux pour r pa rer ce d faut notre plus proche centre de service ou notre atelier de service de Memphis au Tennessee Si aucune pi ce de rechange ne peut tre fournie nous rembourserons le prix d achat r el de votre ventilateur de salle de bain ou nous vous en fournirons un sans frais en remplacement notre choix Apr s cette p riode de cinq ans vous serez responsable pour tous les frais de pi ces et de main d uvre pour les r parations du ventilateur de salle de bain SI LUSAGER RESIDENTIEL INITIAL OU LE CLIENT ACHETEUR CESSE D TRE PROPRI TAIRE DU VENTILATEUR CETTE GARANTIE ET TOUT AUTRE GARANTIE IMPLICITE QUI RESTEN
9. los materiales para reparar la falla ser n proporcionados sin costo en nuestro centro de reparaciones m s cercano o en nuestro Departamento de servicio en Memphis Tennessee Si no puede proporcionarse alguna parte de reemplazo a nuestra elecci n le reembolsaremos el precio de compra real de su Extractor de aire para ba o o le proporcionamos uno de reemplazo sin costo Despu s de este per odo de cinco a os usted ser responsable de todos los costos de partes y mano de obra para reparaciones de cualquier componente del Extractor de aire para ba o SI EL USUARIO O COMPRADOR ORIGINAL DEJA DE POSEER EL EXTRACTOR DE AIRE ESTA GARANT A Y CUALQUIER GARANT A IMPLICITA QUE PERMANEZCA EN EFECTO INCLUYENDO PERO SIN LIMITARSE A TODA GARANT A IMPLICITA DE COMERCIABILIDAD O IDONEIDAD PARA UN PROPOSITO PARTICULAR QUEDA ANU LADA NO SE OFRECE NINGUNA GARANT A EXPRESA O IMPLICITA INCLUYENDO CUALQUIER GARANT A DE COMERCIABILIDAD O IDONEIDAD PARA UN PROPOSITO PARTICULAR PARA LAS LAMPARAS DE VIDRIO O LAS BOMBILLAS O ELACABADO DE CUALQUIER PARTE MET LICA DEL EXTRACTOR DE AIRE PARA BA O ESTA GARANT A SUSTITUYE A TODAS LAS OTRAS GARANT AS EXPRESAS LA DURACI N DE TODA GARANT A IMPLICITA INCLUYENDO PERO SIN LIMITARSE A CUALQUIER GARANT A IMPLICITA DE COMERCIABILIDAD O IDO NEIDAD PARA UN PROPOSITO PARTICULAR CON RESPECTO DE CUALQUIER MOTOR DE EXTRACTOR DE AIRE PARA BA O HUNTER U OTRA PARTE DEL VENTILADOR EST EXPRESAMENTE LIMITADAAL PERIODO DE
10. sdlo de la manera indicada por el fabricante Si tiene alguna pregunta contacte con el fabricante 2 Antes de dar servicio o limpiar la unidad desconecte la ali mentaci n en el tablero de servicio y bloquee los elementos de desconexi n a fin de evitar que la alimentaci n pueda ser conectada accidentalmente Cuando los elementos de descon exi n no pueden ser bloqueados asegure firmemente una forma destacada de advertencia como una etiqueta en el tablero de servicio 3 Los trabajos de instalaci n y cableado el ctrico deben ser realizados por personas calificadas de acuerdo con todos los c digos y las normas aplicables incluyendo el de dise o contra incendio 4 Se necesita aire suficiente para una combusti n adecuada y para evacuar los gases por el tubo de la chimenea de equipo que quema combustible a fin de evitar el flujo inverso Siga las pautas del fabricante del equipo de calefacci n y las A PRECAUCI N S lo para uso de ventilaci n general No use para liberar materiales y vapores peligrosos o explosivos Para evitar da os a los rodamientos del motor soplador e impul sores ruidosos o desbalanceados mantenga la unidad de potencia lejos de la aplicaci n de aerosol para paneles de yeso drywall polvo de la construcci n etc NO instale este producto en una pared Este producto est dise ado para instalarse en techos con una inclinaci n de hasta 12 12 45 La red de ductos debe dirigirse hacia arr
11. 00 77537 01 000 gt gt gt gt 65219 01 000 gt gt gt incluido Herramientas necesarias no suministradas Tiempo estimado de ensamblaje entre 30 y 60 minutos 43041 01 01 31 2008 Antes de la instalaci n NOTA Retire todo el material de embalaje antes de la instalaci n Afloje los tornillos EL Retire las cubiertas de las puntas de tornillo precargadas Retire las puntas de tornillo precargadas hasta que est n a nivel con el lado del alojamiento 43041 01 01 31 2008 Retire el primer tap n met lico de acceso del cableado Utilice Inserte el manguito de alivio de tensi n no se incluye en la el segundo si es necesario caja y suj telo firmemente con una arandela Escoja la opci n de instalaci n Para constricci n nueva fijaci n a la viga vaya al paso A11 p gina 28 Para construcci n nueva suspendido entre vigas vaya al pasa B11 p gina 30 Para construcci n existente accesible desde arriba vaya al paso C11 p gina 33 Para construcci n existente accesible s lo desde abaja vaya al paso D11 p gina 37 43041 01 01 31 2008 Construcci n nueva fijaci n a la viga Ubique la correcta marca de profundidad en el borde inferior Instale los tornillos precargados en la viga o el marco de la viga seg n el espesor de su plancha de yeso Tienda los cables a trav s
12. 008 Probl me Le ventilateur ne fonctionne pas Solution e Les ventilateurs de salle de bain Hunter sont tr s silencieux Pour v rifier que le ventilateur fonc tionne placez votre main pr s des vents pour sentir le mouvement de l air Remettre le courant remplacer le fusible ou r armer le disjoncteur e V rifier toutes les connexions enfichables pour s assurer qu elles sont correctes e V rifier le c blage pour s assurer qu il correspond au diagramme du circuit Probl me La lumi re ne fonctionne pas Solution Remplacer l ampoule e Remettre le courant remplacer le fusible ou r armer le disjoncteur e V rifier toutes les connexions enfichables pour s assurer qu elles sont correctes e V rifier le c blage pour s assurer qu il correspond au diagramme du circuit Probl me Le ventilateur est bruyant Solution e V rifier et resserrer toutes les pi ces de fixation e V rifier que le globe est bien fix e V rifier que le clapet bouge librement Si vous avez besoin de pi ces ou d aide appelez 888 830 1326 ou rendez nous visite sur notre site Web au http www hunterfan com 43041 01 01 31 2008 Hunter Fan Company Ventilateur de salle de bain GARANTIE LIMITEE La soci t Hunter Fan Company Inc offre la garantie limit e suivante a usager initial ou au client acheteur de ce ven tilateur de salle de bain Si une pi ce quelconque de votre ventilateur de salle de bain Hunter l exception
13. 1886 SINCE ENGLISH See page 2 ESPA OL VEEBER ELLE FRAN AIS Consulter la page 45 Model 81021 Victorian Bath Ventilator with Light READ and SAVE THESE INSTRUCTIONS 43041 01 01 31 2008 TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Use this unit only in a manner intended by the manufacturer If Engineers ASHRAE and the local code authorities you have questions contact the manufacturer When cutting or drilling into wall s or ceiling do not Before servicing or cleaning the unit switch power off at ser damage electrical wiring or other hidden utilities vice panel and lock the service disconnecting means to prevent power from being switched on accidentally when the service Ducted fans must always be vented to the outdoors disconnecting means cannot be locked securely fasten a promi nent warning device such as a tag to the service panel If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Installation work and electrical wiring must be done by qualified Fault Circuit Interrupter protected branch circuit person s in accordance with all applicable codes and standards including fire rated construction Never place a switch where it can be reached from a tub or shower Sufficient air is needed for proper combustion and exhausting Install fan at least 5 fe
14. DE Uniquement pour un usage g n ral de ventilation Ne pas s en servir pour ventiler des mat riaux ou des vapeurs dangereux ou explosifs Installer le ventilateur a au moins 1 52 5 pi au dessus du plancher Pour viter des dommages au palier du moteur et des turbines DECO N N ECTE R L ALI M E NTATIO N bruyantes ou mal quilibr es prot ger le groupe moteur de la pein E LECTRIQ U E ET VE RRO U LLE R ture au oe la aie de construction etc LE PAN N EAU DE SE RVICE AVANT ae intake dane lee lane cues Uranga dede ge Ge DE FAIRE L ENTRETIEN DE pointer vers le haut L U N ITE Veuillez lire l tiquette des sp cifications sur le produit pour des ren seignements et conditions suppl mentaires ENTRETIEN PR VENTIF Un ventilateur propre fournit un meilleur service Couper le courant et nettoyer EQUIPEM ENT DE CU ISSON le ventilateur comme indiqu ci dessous POUR NETTOYER LA GRILLE Se servir d un d tergent doux comme du lt Ne rien installer liquide vaisselle et d un chiffon doux Ne pas se servir de chiffons abrasifs x F de tampons de laine d acier ou de poudres r curer au dessus ou dans cette aire POUR NETTOYER L ENSEMBLE DU VENTILATEUR D brancher le cordon du moteur souffleur de la prise Pour retirer la plaque du moteur souffleur rep rer la languette unique sur la plaque situ e pr s de la prise Pousser vers le haut et l arri re la languette de la plaque
15. LA GARANTIA EXPRESA ESTABLECIDA ANTERIORMENTE PARA DICHOS MOTORES U OTRAS PARTES Esta garant a es nula si su Extractor de aire para ba o no se adquiere e instala en los EE UU Esta garant a excluye y no cubre defectos aver as o fallas del Extractor de aire para ba o Hunter que fueran ocasionados por reparaciones por parte de personas no autorizadas por nosotros por el uso de piezas o accesorios no autorizados por nosotros por mal uso modificaciones o da os al Extractor de aire para ba o Hunter mientras est en su posesi n o por un empleo no razon able incluyendo la falta de suministrar un razonable y necesario mantenimiento Para obtener servicio contacte con el centro de servicio autorizado Hunter m s cercano o con nuestro Departamento de servicio de Hunter Fan Company en 2500 Frisco Avenue Memphis Tennessee 38114 Le agradeceremos que se ponga en contacto con nosotros antes de enviarnos su Extractor de aire para ba o Si le autorizamos a enviarlo usted ser responsable de todos los cargos de seguro y flete o de otras cargas del transporte a nuestra planta o centro de reparaciones Devolveremos su Extractor de aire para ba o Hunter con el flete prepagado Su Extractor de aire para ba o Hunter se debe embalar apropiadamente para evitar da os durante el tr nsito ya que no seremos responsables de dichos da os Al solicitar un servicio de garant a debe exhibir una prueba de su compra El comprador debe presentar el recibo de co
16. Problema El ventilador hace ruido Soluci n e Verifique y apriete todos los pernos y tornillos e Verifique la pantalla para asegurarse que est firme e Verifique la clapeta para asegurarse que se mueva con libertad Si necesita repuestos o servicio llame al 888 830 1326 o visite nuestro sitio web en http www hunterfan com 43041 01 01 31 2008 Garantia Hunter Fan Company Extractor de aire para ba o GARANTIA LIMITADA Hunter Fan Company establece la siguiente garantia limitada al usuario o comprador original de este Extractor de aire para ba o Hunter Si alguna pieza de su Extractor de aire para ba o Hunter con excepci n de las lamparas de vidrio y las bombillas falla en cualquier momento dentro de un a o despu s de la fecha de compra debido a una falla de material o mano de obra repararemos o a nuestra elecci n reemplazaremos la pieza defectuosa sin costo de partes y mano de obra realizada en nuestro centro de reparaciones m s cercano o en nuestro Departamento de servicio en Memphis Tennessee Despu s de este per odo de un a o usted ser responsable de todos los costos de partes y mano de obra para reparaciones del Extractor de aire para ba o con excepci n de reparaciones del motor como se estipula a continuaci n Si el motor de su Extractor de aire para ba o Hunter falla en cualquier momento dentro de cinco a os despu s de la fecha de compra debido a una falla de material o mano de obra la mano de obra y
17. T ENCORE VALIDES INCLUANT MAIS SANS Y TRE LIMIT E TOUTE GARANTIE IMPLICITE DE QUALIT MARCHANDE OU DE COMPATIBILIT UN USAGE PARTICULIER SONT ANNUL ES AUCUNE GARANTIE EXPRESSE OU IMPLICITE INCLUANT TOUTE GARANTIE IMPLICITE DE LA QUALIT MARCHANDE OU DE COMPATIBILIT UN USAGE PARTICULIER N EST FAITE L GARD DES PI CES DE VERRE OU DES AMPOULES OU DU FINI DE TOUTE PARTIE M TALLIQUE DU VENTILATEUR CETTE GARANTIE TIENT LIEU DE TOUT AUTRE GARANTIE EXPRESSE LA DUR E DE TOUTE GARANTIE IMPLICITE INCLUANT MAIS SANS Y TRE LIMIT E UNE QUELCONQUE GARANTIE IMPLICITE DE QUALIT MARCHANDE O DE COMPATIBILIT UN USAGE PARTICULIER EST EXPRESS MENT LIMIT E LA P RIODE DE LA GARANTIE EXPRESSE NONC E PLUS HAUT POUR LES MOTEURS ET AUTRES PI CES Cette garantie est nulle si votre ventilateur n a pas t achet et install aux U ou au Canada Cette garantie exclue et ne couvre pas les d fauts les mauvais fonctionnements et les pannes d un ventilateur dus des r parations par des personnes auxquelles nous n avons pas donn d autorisation l utilisation de pi ces ou d accessoires non autoris es un mauvais traitement des modifications ou des dommages au ventilateur tandis qu il tait en votre possession ou un usage d raisonnable y compris l incapacit de fournir un entretien raisonnable et n cessaire Pour b n ficier du service prenez contact avec le centre de service autoris Hu
18. ain relief bracket screw Position the strain relief bracket under the motor as shown Insert the strain relief bracket s dog leg tab so that it hooks Align posts A B C and D stamped into motor housing with over the lip of the motor Reinstall the strain relief bracket posts A B C and D stamped into light fixture Slide light screw 18 fixture over posts 43041 01 01 31 2008 Attach thumbscrews Install 2 Max 60 Watt A15 bulbs Not Included WARNING To reduce the risk of electrical shock all 4 thumbscrews MUST be properly installed Align glass dome and push up Screw Finial into position Complete 43041 01 01 31 2008 Trouble Shooting Problem Fan does not come on Solution e Hunter Fan Bath Ventilators are extremely quiet To confirm that the fan is running place your hand near the vents to feel the air movement e Turn power on replace fuse or reset breaker e Check all plug connections to be sure they are secure e Check the wiring to make sure it matches the wiring diagram Problem Light does not come on Solution e Replace the light bulb with a new bulb e Turn power on replace fuse or reset breaker e Check all plug connections to be sure they are secure e Check the wiring to make sure it matches the wiring diagram Problem Fan is noisy Solution e Check and tighten all fasteners e Check the glass to make sure it is secure e Check the flapper to make sure it moves
19. che en el borde del motor Rein tor soplador con los postes A B C y D estampados en el stale el tornillo del soporte del aliviador de tensiones EN artefacto de iluminaci n Deslice la l mpara sobre los postes 43041 01 01 31 2008 Instale los tornillos de mano ADVERTENCIA Para reducir el Instale 2 bombillas A 15 de 60 vatios como maximo riesgo de descarga el ctrica los 4 tornillos de mano DEBEN No incluidas instalarse apropiadamente Alinee el la pantalla y levante Enrosque la cubierta ornamental Completo 43041 01 01 31 2008 Soluci n de problemas Problema El ventilador no est operando Soluci n e Los ventiladores de ba o Hunter son muy silenciosos Para confirmar que el ventilador est funcionando coloque su mano cerca de los conductos de ventilaci n para sentir el movimiento del aire e Encienda la alimentaci n el ctrica reemplace el fusible o restablezca el interruptor autom tico e Verifique todas las conexiones de los enchufes para asegurarse que est n firmes e Verifique el cableado para asegurarse que coincida con el diagrama de cableado Problema La luz no funciona Soluci n e Reemplace la bombilla con una nueva e Encienda la alimentaci n el ctrica reemplace el fusible o restablezca el interruptor autom tico e Verifique todas las conexiones de los enchufes para asegurarse que est n firmes e Verifique el cableado para asegurarse que coincida con el diagrama de cableado
20. e 18 to attach grille Test the motor If the motor does not run check the plug connection New Construction suspended between joists Slide the mounting rails into brackets Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock Mark position of screws by using holes as a template Drill a hole in the center of each outline 43041 01 01 31 2008 Insert screws leaving space between the screw Attach the rails onto the screws head and the joist Screws are not provided Tighten screws Pull wires through the strain relief Bare Copper PERTE TAC Im 2 Black Switch 2 AC In Connect wires as shown 43041 01 01 31 2008 Install the wiring cover plate Make sure all wiring Connect 4 duct and vent to the outside Tape joints connections are inside the box or under the If ducting does not fit securely an adapter may need wiring cover plate to be purchased Connect wiring from the motor to the wiring cover plate Reinstall the motor by inserting the tabs and pushing up into position Make sure the wires are not pinched between the motor and the housing 524 L a 8 O A ve Secure the motor by tightening the 2 screws Turn on the power source 43041 01 01 31 2008 Test the motor If the motor does not run OFF check t
21. e la conexi n del enchufe Construcci n existente accesible desde arriba C14 VENTILADOR EXISTENTE SIN VENTILADOR EXISTENTE Retire el ventilador existente y aseg rese que la abertura sea Utilice el alojamiento del motor soplador como una plantilla suficientemente grande para acomodar el alojamiento del para marcar la posici n motor soplador nuevo 8 pulg x 8 1 2 pulg Recorte una abertura para el alojamiento Deslice los rieles de montaje en los soportes 43041 01 01 31 2008 Ubique la correcta marca de profundidad en el borde inferior Marque la posici n de los tornillos utilizando los agujeros como de la viga seg n el espesor de su plancha de yeso una plantilla Introduzca los tornillos dejando espacio entre la cabeza del tornillo y la viga No se proporcionan los tornillos Fije los rieles con los tornillos Apriete los tornillos 43041 01 01 31 2008 Conecte un ducto de 4 y ventile hacia el exterior Aplique cinta Tienda los cables a trav s del manguito de alivio de tension a las uniones Si el ducto no se ajusta firmemente puede ser necesario comprar un adaptador Apriete los tornillos del aliviador de tensiones Cobre desnudo Motor del Negro Interruptor principal 1 CA ventilador Negro Interruptor 2 CA Conecte los alambres como se muestra 43041 01 01 31 2008 Instale la placa de cubierta del cableado Asegurese que Conecte el mazo de cabl
22. ef into the housing and secure with the washer Choose Installation Option For New Construction attaching to joist fo to step A11 page 6 For New Construction suspended between joists go to step B11 page 8 For Existing Construction accessible from above go to step C11 page 11 For Existing Construction accessible only from below go to step D11 page 15 43041 01 01 31 2008 New Construction attaching to joist Position the correct depth mark at the bottom edge of the joist Screw pre loaded screws into joist or framing based on the thickness of your sheetrock Pull wires through the strain relief Ground Green Bare Copper Black Main Switch 1 AC In Black Switch 2 AC In Connect wires as shown 43041 01 01 31 2008 Install the wiring cover plate Make sure all Connect 4 duct and vent to the outside Tape joints wiring connections are inside the box or under If ducting does not fit securely an adapter may need the wiring cover plate to be purchased pa al Connect wiring from the motor to the wiring cover plate Reinstall the motor by inserting the tabs and pushing up into position Make sure the wires are not pinched between the motor and the housing Secure the motor by tightening the 2 screws Turn on the power source 43041 01 01 31 2008 A21 Go to step EC OFE on pag
23. enter of the Hunter Fan Company Service De partment 2500 Frisco Avenue Memphis Tennessee 38114 Please contact us before shipping your bath exhaust fan to us If we authorize you to ship it to us you will be responsible for all insurance and freight or other transpor tation charges to our factory or service center We will return your Hunter bath exhaust fan freight prepaid Your Hunter bath exhaust fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage Proof of purchase is required when requesting warranty service The purchaser must present the sales receipt or other document that establishes proof of purchase IN NO EVENT SHALL HUNTER FAN COMPANY BE LIABLE FOR CONSEQUENTIAL OR INCIDENTAL DAM AGES SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EX CLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSIONS MAY NOT APPLY TO YOU THE WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE 21 2008 Hunter Fan Company 43041 01 01 31 2008 43041 01 01 31 2008 Modelo 81021 Victorian Ventilador para ba o con luz LEA y CONSERVE ESTAS INSTRICCIONES 43041 01 01 31 2008 m D gt 2 e E AADVERTE NC A PARA REDUCIR EL RIESGO DE INCENDIO CHOQUE EL CTRICO O LESIONES A PERSONAS OBSERVE LO SIGUIENTE 1 Utilice esta unidad
24. ers le haut en place Assurez vous que les fils n ont pas t pinc s entre le moteur souffleur et le boitier Remettre le courant Essayer le moteur souffleur Si le moteur souffleur ne fonc tionne pas v rifier la connexion enfichable Aller l tape E a la page 62 pour fixer la grille 43041 01 01 31 2008 Fixation de la grille Retirer les vis a serrage a main Connecter le cablage NE LAISSER PAS LA LUMINAIRE PENDRE PAR LE CABLAGE Retirer la vis de l trier 2 de d charge de traction Placer l trier de d charge de traction 3 sous le moteur tel qu illustr Ins rer la languette de d centrage de l trier de d charge de Aligner les tenons A B C et D rivet s au bo tier du moteur traction afin qu elle s accroche la l vre du moteur Reposer la souffleur avec les trous A B C et D de lembase du luminai vis de l trier de d charge de traction A re Faire glisser l embase du luminaire sur les tenons 43041 01 01 31 2008 Visser les vis serrage main MISE EN GARDE Pour r duire le risque de choc lectrique Poser des ampoules A15 de 60 w max Non comprises les quatre vis serrage main DOIVENT tre correctement viss es Vissez le d me de d me en place Visser la finial en place Compl ter 43041 01 01 31 2
25. es NO PERMITA QUE EL MOTOR todas las conexiones de cableado est n dentro de la caja o SOPLADOR CUELGUE DEL MAZO DE CABLES debajo de la placa de cubierta del cableado Vuelva a instalar el motor soplador introduciendo las pesta as Asegure el motor soplador apretando los 2 tornillos y levantando a su posici n Aseg rese que los alambres no se pellizquen entre el motor soplador y el alojamiento Encienda la fuente de alimentaci n Pruebe el motor soplador Si el motor soplador no funciona verifique la conexi n del enchufe 43041 01 01 31 2008 Vaya al paso E en la p gina 40 para fijar la rejilla Construcci n existente accesible s lo desde abajo Retire el ventilador existente y aseg rese que la abertura sea Mueva el alojamiento a su posici n encima del techo suficientemente grande para acomodar el alojamiento del motor soplador nuevo 8 pulg x 8 1 2 pulg Tienda los cables a trav s del manguito de Conecte el ducto existente con el conector de ducto Aplique alivio de tension cinta a las uniones Si el ducto no se ajusta firmemente puede ser necesario comprar un adaptador 43041 01 01 31 2008 Instale el alojamiento a nivel con la plancha de yeso y asegurelo apretando los tornillos precargados en la viga clavijas Blanco Cobre desnudo Motor del Negro Interruptor principal 1 CA SN ventilador fi fA Blanco y J Z l
26. et 1 52 m above the floor of gasses through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufac This unit must be grounded turer s guideline and safety standards such as those published by the National Fire Prevention Association NFPA and the Unit must not be installed in a ceiling thermally insulated to a value American Society for Heating Refrigeration and Air Conditioning greater than R40 A CAUTION A WARNING For general ventilating use only Do not use to exhaust haz ardous or explosive materials and vapors D SCO N N ECT E LECTRI C To avoid motor bearing damage and noisy unbalanced impel lers keep drywall spray construction dust etc off power POWE R S U PPLY DO NOT install this product ina wall This product is AN D LOCK OUT ja a Me SERVICE PANEL BEFORE ea as aa label on product for further infor S E RV Cl N G U N IT PREVENTATIVE MAINTENANCE A clean fan provides better service Disconnect the power supply and clean the fan as listed below COOKING AREA Do Not Install Above TO CLEAN GRILLE Use a mild detergent such as dishwashing liquid and a soft cloth DO NOT use abrasive cloths steel wool pads or scouring powders Or Inside This Area TO CLEAN FAN ASSEMBLY Unplug motor cord from receptacle To remove motor plate find the single tab on the motor plate located next to the recepta cle Push up rear motor plate tab while
27. freely If you need parts or service assistance please call 888 830 1326 or visit us at our web site at http www hunterfan com 43041 01 01 31 2008 Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan If any part of your Hunter bath exhaust fan except for glass fixtures and light bulbs fails at any time within one year afterthe date of sale to you due to a defect in material or workmanship we will repair or at our option replace the defective part free of charge for parts and labor performed at our nearest service center or at our Service Depart ment in Memphis Tennessee After this one year period you will be responsible for all parts and labor costs for repairs on the bath exhaust fan except for motor repairs as provided below If your Hunter bath exhaust fan motor fails at any time within five years after the date of sale to you due to a defect in material or workmanship labor and materials to repair the defect will be provided free of charge at our nearest service center or our Service Department in Memphis Tennessee If no replacement part can be provided we will at our option either refund the actual purchase price of your bath exhaust fan or provide a replacement free of charge After this five year period you will be responsible for all parts and labor costs for repairs on all parts of the
28. he plug connection Existing Construction accessible from above EXISTING FAN Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing 8 x 8 5 Cut out an opening for the housing 43041 01 01 31 2008 Go to step E on page 18 to attach grille NO EXISTING FAN Slide the mounting rails into brackets Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock Insert screws leaving space between the screw head and the joist Screws are not provided Attach the rails onto the screws Tighten screws 43041 01 01 31 2008 Connect 4 duct and vent to the outside Tape joints Pull wires through the strain relief If ducting does not fit securely an adapter may need to be purchased Ground 3 Green A Bare Copper S Black Main Switch 1 AC In SN Black Switch 2 AC In Connect wires as shown 43041 01 01 31 2008 Install the wiring cover plate Make sure all wiring Connect wiring from motor the motor connections are inside the box or under the to the wiring cover plate wiring cover plate Reinstall the motor by inserting the tabs and pushing up into Secure the motor by tightening the 2 screws position Make sure the wires are not pinched between the motor and the housing C28 ON G OFF
29. iba Vea m s informaci n y los requisitos en la etiqu eta de especificaci n del producto MANTENIMIENTO PREVENTIVO UN VENTILADOR LIMPIO PROPORCIONA MEJOR SERVICIO DESCONECTE LA ALIMENT ACI N Y LIMPIE EL VENTILADOR COMO SE INDICA A CONTINUACI N PARA LIMPIAR LA REJILLA USE un DETERGENTE SUAVE COMO L QUIDO PARA LAVADO DE PLATOS Y UN PA O SUAVE NO EMPLEE PA OS ABRASIVOS ALMOHA DILLAS DE LANA DE ACERO NI POLVOS PARA FREGAR PARA LIMPIAR EL CONJUNTO DEL VENTILADOR pesconecte EL CORD N DEL MOTOR SOPLADOR DE LA TOMA DE CORRIENTE PARA RETIRAR LA PLACA DEL MOTOR SOPLADOR ENCUENTRE LA PESTA A EN LA PLACA UBICADA JUNTO ALATOMA DE CORRIENTE LEVANTE LA PESTA A POSTERIOR DE LA PLACA DEL MOTOR SOPLADOR MIENTRAS EMPUJA HACIA AFUERA EN EL LADO DEL ALOJAMIENTO O INTRO DUZCA UN DESTORNILLADOR EN LA RANURA DEL ALOJAMIENTO JUNTO A LA PESTA A Y GIRE EL DESTORNILLADOR SUAVEMENTE ASPIRE EL VENTILADOR EL MOTOR SOPLA DOR Y EL INTERIOR DEL ALOJAMIENTO LAS PARTES MET LICAS EL CTRICAS NUNCA DEBEN SUMERGIRSE EN AGUA MANTENIMIENTO EL MOTOR SOPLADOR EST LUBRICADO PERMANENTEMENTE Y NO NECESITA SER ENGRASADO SI LOS RODAMIENTOS DEL MOTOR SOPLADOR HACEN RUIDOS EXCESIVOS normas de seguridad como las de la Asociaci n Nacional de Protecci n contra Incendios NFPA la Asociaci n de Ingenieros Americanos en Calefacci n y Aire acondicionado ASHRAE y los c digos locales Al cortar o taladrar en paredes o tech
30. le moteur souffleur ne fonc tionne pas v rifier la connexion enfichable 43041 01 01 31 2008 Aller a l tape 9 a la page 62 pour fixer la grille Construction existante accessible uniquement du dessous EXISTING FAN Enlever un ventilateur existant et v rifier que l ouverture est Mettre le bo tier en place au dessus du plafond assez grande pour permettre la pose d un nouveau bo tier de moteur 203 mm x 216 mm 8 po x 8 5 pol Passer les fils par le raccord Fixer la gaine existante au connecteur de gaine Jointer avec du ruban Si la gaine n est pas de la bonne dimension vous EN pourriez devoir acheter un adaptateur 43041 01 01 31 2008 Installer le bo tier affleurant la plaque de gypse et le fixer en vissant les vis pr install es dans la solive Prise de terre ES Vert a oe Cuivre nu Noir Interrupteur principal 1 entree CA X du ventilateur Lumi re O Noir Interrupteur principal 2 entree CA Connecter les fils tel qu indiqu Installer la plaque de couvercle du cablage Assurez vous que Connecter le cablage NE LAISSER PAS LE MOTEUR toutes les connexions de cablage sont dans la boite ou der SOUFFLEUR PENDRE PAR LE CABLAGE ri re la plaque de couvercle du cablage 60 43041 01 01 31 2008 tm Y a Reposer le moteur souffleur en ins rant les languettes et en le Fixer le moteur souffleur en serrant les deux vis poussant v
31. mpra u otro documento que establezca la prueba de su compra EN NING N CASO HUNTER FAN COMPANY SER RESPONSABLE DE DA OS PERJUDICIALES O ACCESORIOS ALGUNOS ESTADOS NO PERMITEN LIMITACIONES SOBRE LA DURACI N DE UNA GARANT A IMPL CITA OLA EXCLUSION O LIMITACI N DE DA OS ACCESORIOS O PERJUDICIALES POR LO QUE LA LIMITACI N O EXCLU SIONES ANTES MENCIONADAS PUEDEN NO APLICARSE A USTED LA GARANT A LE DA DERECHOS LEGALES ESPEC FICOS PERO USTED TAMBI N PUEDE TENER OTROS DERECHOS QUE VAR AN DE ESTADO A ESTADO O 2008 Hunter Fan Company 43041 01 01 31 2008 43041 01 01 31 2008 e I I I I I I I Model 81021 Victorian Ventilateur de salle de bain avec lumi re LIRE ET CONSERVER CES CONSIGNES 43041 01 01 31 2008 TI 2 gt Z O a 7 MISE EN GARDE POUR REDUIRE LE RISQUE D INCENDIE DE DECHARGE LECTRIQUE OU DE BLESSURES VEUILLEZ SUIVRE LES DIRECTIVES SUIVANTES 1 Utiliser cet appareil seulement de la fa on pr vue par le fabri l association nationale de protection contre les incendies NFPA cant Si vous avez des questions communiquer avec le fabri National Fire Protection Association la soci t am ricaine des ing cant nieurs en chauffage r frig ration et climatisation ASHRAE American Avant l entretien ou le nettoyage de cet appareil couper le Society for Heating Refrigeration and Air Conditioning Engineers et courant au panneau de service et verrouiller les moyens de le
32. necter les fils tel qu indiqu 43041 01 01 31 2008 Installer la plaque de couvercle du cablage Assurez vous que Raccorder la gaine de 4 po et l vent a l ext rieur Jointer avec toutes les connexions de cablage sont dans la boite ou der du ruban Si la gaine n est pas de la bonne dimension vous ri re la plaque de couvercle du cablage pourriez devoir acheter un adaptateur Connecter le cablage NE LAISSER PAS LE MOTEUR Reposer le moteur souffleur en ins rant les languettes et en le SOUFFLEUR PENDRE PAR LE CABLAGE poussant vers le haut en place Assurez vous que les fils n ont pas t pinc s entre le moteur souffleur et le boitier Fixer le moteur souffleur en serrant les deux vis Remettre le courant 43041 01 01 31 2008 Aller a l tape la page 62 pour fixer la grille Essayer le moteur souffleur Si le moteur souffleur ne fonc tionne pas v rifier la connexion enfichable Construction existante accessible du dessus Enlever un ventilateur existant et v rifier que l ouverture est Utiliser le bo tier du moteur comme gabarit pour marquer sa assez grande pour permettre la pose d un nouveau bo tier de position moteur 203 mm x 216 mm 8 po x 8 5 pol D couper une ouverture pour le bo tier Faire glisser les glissi res de fixation dans les supports 43041 01 01 31 2008 Placer la
33. nter le plus proche ou avec l atelier de service de la soci t Hunter Fan Company 2500 Frisco Avenue Memphis Tennessee 38114 Veuillez communiquer avec nous au 901 248 2222 avant de nous exp dier votre ventilateur de salle de bain Si nous vous autorisons faire cet envoi Vous devrez assumer les frais d assurance et de transport notre usine ou notre centre de service Nous vous retournerons votre ventilateur de salle de bain Hunter en port pr pay Votre ventilateur de calle de bain devra tre emball avec soin pour viter tout dommage durant le transport puisque nous ne pourrons tre tenus responsables d un tel dommage Une preuve d achat est exig e pour obtenir un service de garantie L acheteur devra pr senter une facture ou un autre document qui tablit la preuve de l achat EN AUCUN CAS LA SOCI T HUNTER FAN COMPANY NE SERA TENUE RESPONSABLE DES DOMMAGES ACCESSOIRES OU INDIRECTS CERTAINS ETATS OU PROVINCES N AUTORISENT PAS DE RESTRICTIONS SUR LA DUREE DE LA GARANTIE IMPLICITE OU SUR LEXCLUSION OU LA RESTRICTION DES DOMMAGES ACCESSOIRES OU INDIRECTS PAR CONSEQUENT LA RESTRICTION OU LES EXCLUSIONS CI DESSUS POURAIENT NE PAS S APPLIQUER A VOUS CETTE GARANTIE VOUS DONNE DES DROITS LEGAUX SPECIFIQUES ET VOUS POURRIEZ EGALEMENT AVOIR D AUTRES DROITS QUI PEUVENT VARIER SELON LES TATS ET LES PROVINCES 65 2008 Hunter Fan Company 43041 01 01 31 2008
34. o no da e el cableado el ctrico u otros servicios no visibles Los ventiladores canalizados siempre deben descargar al aire libre Si va a instalar esta unidad en una ba era o ducha debe tener una 10 11 marca que indique que es apropiado para ese uso y debe conectarse a un circuito derivado protegido por un GFCI interruptor autom tico de falla a tierra Nunca coloque un interruptor donde pueda ser alcanzado desde una tina o una ducha Instale el ventilador por lo menos a 5 pies 1 52 m por encima del piso Esta unidad se debe poner a tierra La unidad no debe ser instalada en un techo con aislamiento t rmico mayor que R40 ADVERTENCIA DESCONECTE LA ALIMENTACI N EL CTRICA Y CIERRE EL PANEL DE SERVICIO ANTES DE DAR MANTENIMIENTO A LA UNIDAD AREA DE LACOCINA No instale sobre o dentro de esta area PA Y 4 w s 45 45 JRO ARS 4 Equipo de cocina O INUSUALES REEMPLACE EL MOTOR SOPLADOR CON EL MOTOR SOPLADOR DE SERVI CIO EXACTO DEBE REEMPLAZAR EL IMPULSOR AL MISMO TIEMPO EN 43041 01 01 31 2008 Verifique todos los componentes Si estan da a dos llame al 1 866 405 3814 i Tornillos para obtener un reemplazo y adicionales D 95044 01 000 gt 95029 01 000 gt 75191 01 000 03242 07 133 98037 01 000 74508 03 133 77521 01 000 97956 01 000 75184 01 133 97958 01 0
35. outes les connexions de c blage sont dans la bo te ou der du ruban Si la gaine n est pas de la bonne dimension vous ri re la plaque de couvercle du c blage pourriez devoir acheter un adaptateur Connecter le c blage NE LAISSER PAS LE MOTEUR Reposer le moteur en ins rant les languettes et en le SOUFFLEUR PENDRE PAR LE CABLAGE poussant vers le haut en place Assurez vous que les fils n ont pas t pinc s entre le moteur souffleur et le bo tier Fixer le moteur souffleur en serrant les deux vis Remettre le courant 43041 01 01 31 2008 Aller a l tape 9 a la page 62 pour fixer la grille Essayer le moteur souffleur Si le moteur souffleur ne fonc tionne pas v rifier la connexion enfichable Faire glisser les glissi res de fixation dans les supports Placer la bonne marque de profondeur sur le bord inf rieur de la solive selon l paisseur de votre plaque de gypse Marquer la position des vis en vous servant des Percer un trou au centre de chaque trait trous comme gabarit 43041 01 01 31 2008 Ins rer les vis en laissant un espace entre la t te de la Fixer les glissi res sur les vis vis et la solive Les vis ne sont pas fournies Visser les vis Passer les fils par le raccord Prise de terre Mot A acne r Y Lumi re O Noir Interrupteur principal 2 entree CA Con
36. pushing out on the side of the housing or insert a screwdriver into the slot in the housing next to tab and twist screw driver Gently vacuum fan motor and interior of housing METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER MAINTENANCE The motor is permanently lubricated and never needs oiling If the motor bear Cooking ings are making excessive or unusual Equipment noises replace the motor with the exact service motor You should replace the impeller at the same time 43041 01 01 31 2008 Check all the parts If damaged call 1 888 830 1326 Extra Screws for replacements gt 95044 01 000 gt 95029 01 000 gt 75191 01 000 03242 07 133 98037 01 000 74508 03 133 77521 01 000 gt gt gt gt 65219 01 000 gt gt gt 97956 01 000 75184 01 133 97958 01 000 77537 01 000 Included Tools Needed Estimated assembly time 30 to 60 minutes 43041 01 01 31 2008 Before Installation NOTE Remove all packing materials before installation Turn off the power source Loosen screws Remove the pre loaded screw tip covers Back out the pre loaded screw tips until flush with the side of the housing 43041 01 01 31 2008 Pop out the first wiring access slug Use second if needed Insert the strain reli
37. s administrations des codes locaux d connexion pour emp cher que le courant soit remis acciden Ne pas endommager le c blage lectrique ou autres quipements tellement Si vous ne pouvez pas verrouiller les moyens de cach s en coupant ou en per ant les murs ou le plafond d connexion bien attacher un dispositif de mise en garde visible Les ventilateurs canalis s doivent toujours disposer d une vacuation comme une tiquette au panneau de service vers l ext rieur Une personne qualifi e doit effectuer le travail d installation et Si cet appareil doit tre install au dessus d un bain ou d une douche de c blage lectrique conform ment tous les codes et normes il doit tre identifi comme appropri cet usage connect un dis applicables y compris les codes et normes de la construction joncteur de fuite la terre pare feu Ne jamais poser un interrupteur qu on pourrait atteindre depuis une ll faut suffisamment d air pour une bonne combustion et un bon baignoire ou une douche chappement des gaz par le conduit chemin e de l quipement br lant le combustible pour emp cher un refoulement Suivre les directives du fabricant de votre installation de chauffage ainsi que Il faut mettre cette unit la terre les normes de s curit telles que celles publi es par II ne faut pas installer cet appareil dans un plafond ayant une isolation thermique sup rieure a R40 A ATTENTION A MISE EN GAR
38. zando los agujeros como una plantilla como una plantilla 43041 01 01 31 2008 Introduzca los tornillos dejando espacio entre la cabeza del Fije los rieles con los tornillos tornillo y la viga No se proporcionan los tornillos Apriete los tornillos Tienda los cables a trav s del manguito de alivio de tension Blanco Cobre desnudo Motor del Negro Interruptor principal 1 CA WE ventilador a Y Blanco WO lt iP Luz O Negro Interruptor 2 CA Conecte los alambres como se muestra 43041 01 01 31 2008 Instale la placa de cubierta del cableado Asegurese que Conecte un ducto de 4 y ventile hacia el exterior Aplique todas las conexiones de cableado est n dentro de la caja o cinta a las uniones Si el ducto no se ajusta firmemente debajo de la placa de cubierta del cableado Conecte el mazo de cables NO PERMITA QUE EL MOTOR Vuelva a instalar el motor soplador introduciendo las pesta as SOPLADOR CUELGUE DEL MAZO DE CABLES y levantando a su posici n Aseg rese que los alambres no se pellizquen entre el motor soplador y el alojamiento 524 E T 8 O A iz Asegure el motor soplador apretando los 2 tornillos Encienda la fuente de alimentaci n 43041 01 01 31 2008 Vaya al paso 9 en la p gina 40 para fijar la rejilla Pruebe el motor soplador Si el motor soplador no funciona verifiqu