Home

Hunter Engineering Quick Tread Specification Sheet

image

Contents

1. Quick Check Drive Thru with Quick Tread Flush Mounted A 15 ft RECOMMENDED BAY WIDTH For inspection information visit www hunter com inspection Drive Thru Quick Check and Flush Mount Quick Tread Power Requirements Air Supply Req IS Units Approximate Air Consumption Pedestal Location Max Wheel Weight Test Entry Speed N E S Quick Check Cabinet Quick Check Drive Under Sensor Quick Tread Installation Amperage shown is minimal circuit rating Substructure Specifications HUNTER Engineering Company Site Specifications 115 230v 15 amp 50 60 Hz 1 ph 90 150 PSI 6 2 10 3 bar 25 SCFM 90 PSI 648 Lom 6 2 bar Refer to Form 6905 T 36 96 in 914 2438 mm from QT1F Product Specifications 3500 Ib 1588 kg per wheel 2 to 8 mph 3 13 km h Shipping Weight 290 Ibs 132 kg f g 316 Ibs 143 kg 1723 Ibs 455 kg Isolated ground recommended QUICK TREAD COMMUNICATION CABLES UP TO 75 ft DISTANCE OF LONGEST WHEELBASE VEHICLE TO BE TESTED TYPICAL 165 in v 93 in 7 ft 9 in OPTIONAL PEDESTAL LOCATION For general inquiries visit www hunter com or call 800 448 6848 END OF BAY TO a FRONT WHEEL STOP gt TYPICAL 120 in MINIMUM 95 in 108 in 114 in 9 ft 9 ft 6 in TYPICAL RECOMMENDED BAY LENGTH 28 ft 4 in TO 26 ft 3 in For local contact visit www hunter com company findrep
2. cfm Form 6895 T 05 15a Copyright 2015 Hunter Engineering Company Quick Check Drive Thru with Quick Tread HUNT EF Flush Mounted Engineering Company lt 24 1 2 in 67 1 4 in 5 ft 7 1 4 in 50 in 45 1 4 in 34 1 2 it I S 17 3 8 in a J5 in I M 23 1 2 in A gt 12 in p l l l i lt 26in gt lt 4 36 in lt __ 26in 51 in 96 in 8 ft is the maximum distance between the middle of the pedestal and nearest edge of Quick Tread Any further will reduce max vehicle test entry speed 36 to 96 in 93 in l gt m ii lt _ lt 3 ft to 8 ft 7 ft 9 in END VIEW SIDE VIEW QUICK TREAD Quick Tread s 3 in M QUICK TREAD o ij underground conduit must e SUB STRUCTURE _ be routed to the pedestal CONTRACTOR according to local codes The pedestal can be placed on SUPPLIED either side Exact placement of conduit will vary Refer to Form 6905 T I I lt _ 51 in gt y lt __ 9 in pay FLOOR 8 in l Form 6895 T 05 15a Copyright 2015 Hunter Engineering Company

Download Pdf Manuals

image

Related Search

Related Contents

Cypress CY7C1231H User's Manual    "取扱説明書"  三菱電機株式会社 中津川製作所  Manual - Ionfilter  Expert Sleepers Augustus Loop v2.0.1 User Manual  USER MANUAL  Jabra Tour  ・取り付けの前には必ずこの取扱説明書を最後まで読み、  ファイル名:kouhou2005 サイズ:5.89 MB  

Copyright © All rights reserved.
Failed to retrieve file