1. 0 2 423 4X 24 Route all cables to allow unrestricted movement of the assembly when sliding in and out Attach wires to cable retractor Figure 1 3 item 26 using cableties Figure 1 3 item 27 20 Chapter1 WARNING CAUTION Addendum to D Class Enterprise Servers System Installation Guide DC Power Supply DC Power Supply The HP 9000 Series 800t D Class Server contains a NEBS compatible direct current DC power supply rather than the alternating current AC power supply furnished with the standard HP 9000 D Class computer This switching power supply is designed to work on DC by replacing the AC input module with a DC to DC converter module This DC power supply directly replaces the standard AC supply for the purpose of operating this computer from a telephone central office negative 48 volt battery or negative 60 volt battery input A shock hazard exists Do not attempt to power up the power supply system outside the computer system chassis The power supply requires a load and other enabling signals to operate properly This DC power option provides a D Class computer server compatible to NEBS requirements for operation in a Central Office environment where equipment is powered from 48VDC batteries The power supply also provides alarm outputs in the form of relay contact closures to indicate a power supply failure An additional feature provides a remote c
2. 26 IEC Statement Worldwide 26 International a Loria OS dale aad sides ate de egy ay de date a ee 27 VCCI Class A Statement J apan Only 27 Sp cification ATI Classe A France seulement 27 Product Noise Declaration Germany Only 28 EMC Regulatory 29 EMC Certification 29 EMG Labels u 40 a a a a na ae 29 SE LS ii a A a ee 29 Safety Certification 29 Safety Labels aan ae eh he 29 Contents 1 Addendum to D Class Enterprise Servers System Installation Guide Addendum to D Class Enterprise Servers System Installation Guide Contents Contents e Purpose of this Addendum e Seismic Rack Kit e Installation DC Power Supply 8 Chapter 1 Addendum to D Class Enterprise Servers System Installation Guide Purpose of this Addendum Purpose of this Addendum This addendum provides information and procedures for installation of a Hewlett Packard 9000 Series 800t D Class Server in a Central Office It provides information about differences between this computer and the Hewlett Packard D Class Enterprise Server and contains the following procedures not found in the D Class Enterprise Servers System Installation Guide e Earthquake mounting of an HP 9000 Series 800t D Cl
3. 110 Ibs Use Two people to lift the D Class server cabinet 16 With tray extended hoist computer into position aligning base with locator pins in tray Slide tray and computer into rack and secure at three places with thread forming screws hardware item 22 at rear of tray 17 With the computer positioned into the rack fasten knurled screws in latch panel to lower tabs in bezel mount brackets NOTE tighten securely 18 Chapter 1 Addendum to D Class Enterprise Servers System Installation Guide Installation 18 Attach the latch panel item 4 to front of mounting tray using five Screws 19 With the computer securely engaged within the rack assembly check alignment of top cover refer to Step 10 and tighten all fasteners Figure 1 5 Seismic Rack Installation D Class Server 20 Install the emblem insert and door removed from the standard bezel refer to Step 3 onto the wide bezel Figure 1 6 item 14 21 Remove handles from the wide bezel and position it onto the bezel mounts attached to the rack 22 Apply lock label item 15 to the front door where shown Chapter 1 19 Addendum to D Class Enterprise Servers System Installation Guide Installation 23 Secure the bezel tothe bezel mounts with the cover plates item 10 2 places shown in Figure 1 6 Figure 1 6 Seismic Rack Installation Fi Por RAIS one ER pa E a Ce Le Le to y amp Eo A A Dee BN RT
4. to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The end user of this product should be aware that any changes or modifications made to this equipment without the approval of Hewlett Packard could result in the product not meeting the Class A limits in which case the FCC could void the user s authority to operate the equipment IEC Statement Worldwide This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures 26 Appendix A Regulatory Safety Statements International International VCCI Class A Statement J apan Only CORB FREE eee Se lies VCCI OEE EX 05 2A Tae CT CORRE SR CHEMIE ER Des Re IL EU ET COA EN ASH ES ES Nec by ET Sp cification ATI Classe A France seulement DECLARATION D INSTALLATION ET DE MISE EN EXPLOITATION d un mat riel de traitement de l information ATI class A en fonction des niveaux de perturba
5. 991 Al A2 A3 EN 60950 1992 A1 A2 A3 GR 63 CORE 1995 Seismic Zone 4 EMC CISPR 22 1993 EN 55022 1994 Class A2 EN 50082 1 1992 TEC 801 2 1991 prEN 55024 2 1992 4 kV CD 8kV AD IEC 801 3 1984 prEN 55024 3 1991 3 V m IEC 801 4 1988 pr EN55024 4 1992 0 5 kV Signal Lines 1 kV Power Lines Supplementary Information The product herewith complies with the requirements of the Low Voltage Directive 73 23 EEC and the EMC Directive 89 336 EEC and carries the CE marking accordingly 1 Product models where y is equal to 0 through 5 meet the EMC directive as attested to in Certificate Number RFI CBC1 3397A 2 The product was tested in a typical configuration with Hewlett Packard computer peripherals Roseville June 25 1997 Frank Dembski Quality Manager European Contact Your local Hewlett Packard Sales Service Office or Hewlett Packard GmbH Department TRE Herrenberger Strasse 130 D 71034 Boblingen Germany FAX 49 7031 14 3143 30 Appendix A
6. Addendum to D Class Enterprise Servers Installation and User s Guide Third Edition HP 9000 Series 800t Computers Us HEWLETT PACKARD Manufacturing Part Number Z7634 96002 February 2000 Communications Infrastructure Computer Operation Copyright 2000 Hewlett Packard Company Notice Theinformation contained in this document is subject to change without notice HEWLETT PACKARD MAKES NO WARRANTY OF ANY KIND WITH REGARD TO THE MATERIAL INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Hewlett Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material Hewlett Packard assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Hewlett Packard This document contains proprietary information which is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated to another language without the prior written consent of Hewlett Packard Company O Copyright 1997 1998 2000 Hewlett Packard Company Printing History ThePrinting History below identifies the edition of this manual and any updates that are induded Periodically update packages are distributed which contain replacement pages to be merged into the manual including an updated copy of
7. Label Lock 1 15 Z7616 80005 Pan Screw 12 24 x 62 20 16 2940 0289 10 Chapter 1 Addendum to D Class Enterprise Servers System Installation Guide Seismic Rack Kit Table 1 1 Earthquake Rack Mount Components Description Quantity Item Part Number Number Split Lock Washer 12 10 17 2190 0631 Flat Washer 12 10 18 3050 0103 Screw 10 32 x 38 Torx Pan 28 19 2680 0281 Flat Washer 10 8 20 3050 0226 Nut w lock 10 32 8 21 2740 0003 Screw 6 32 thread forming 3 22 0624 0727 Screw 6 32 X 38 Pozi flat 4 23 2360 0196 Screw 12 24 X 38 Pozi flat 6 24 2940 0297 Screw 6 32 X 38 Torx Pan 5 25 C2260 20001 Ass y Cable Retractor 1 26 Z7616 60009 Cable Tie 11 long 10 27 1400 0482 Clip Bezel Attach 2 2 opt 28 C2786 40002 Screw M4 x 0 7 X 8 Torx Pan 2 2opt 29 0515 0433 Receptacle Clip on 2 30 1390 1090 Chapter 1 11 Addendum to D Class Enterprise Servers System Installation Guide Seismic Rack Kit Site Hazard Considerations Hewlett Packard recommends the following environmental and mechanical factors for review and compliance prior to installation of equipment 85 F T mra Manufacturer s maximum recommended ambient temp 1 Elevated Operating Ambient Temp If installed in a multi unit rack assembly consider air conditioning or ventilation to avoid exceeding 85 F Reduced Air Flow Installation of equi
8. ass Server in a Central Office equipment frame e Connecting DC Power to an HP9000 Series 800t D Class Server Tools Needed Phillips head screw drivers size 3 and 1 e Nut driver or socket or open end size 3 8 in e Star point Torx drivers size 15 and 25 e Needlenose pliers Chapter 1 9 Addendum to D Class Enterprise Servers System Installation Guide Seismic Rack Kit Seismic Rack Kit TheHP 9000 Series 800t D Class Server can befitted with a seismicrack mount kit for installation in a 19 inch open relay rack This earthquake rack fulfills Bellcore requirements for Telecommunication equipment installed in a NEBS compatible central office Table 1 1 shows the parts induded for this installation and identification numbers for each component as it appears on Figure 1 1 through Figure 1 6 Table 1 1 Earthquake Rack Mount Components Description Quantity Item Part Number Number Assembly Top Cover 1 1 Z7616 60008 Bracket Main Left 1 2 Z7616 00009 Bracket Main Right 1 3 Z7616 00010 Assembly Panel Latch 1 4 Z7616 60005 Bezel Mount Left 1 5 Z7616 00012 Bezel Mount Right 1 6 Z7616 00013 Pan Base 1 7 Z7616 00014 Support Bezel 1 8 Z7616 00015 Bracket Rear 2 9 Z7630 00001 Plate Cover 2 10 Z7630 00016 Assembly Slide Left 1 11 Z7616 60003 Assembly Slide Right 1 12 Z7616 60004 Weldment Mounting Tray 1 13 A3262 60024 Assembly Rack Bezel 1 14 A3262 60036
9. g hardware item 24 Table 1 1 on page 10 The bracket panel is oriented top to bottom as shown in Figure 1 2 Align the upper counter sunk hole on the panel with the hole in the vertical channel that was noted in the previous step 6 Attach the rear brackets Figure 1 2 item 9 2 places tothe right and left main brackets using item 19 hardware in three places as shown Attach torear of relay rack using hardware items 16 17 and 18 4 pls each side 14 Chapter 1 Addendum to D Class Enterprise Servers System Installation Guide Installation 7 Assemble base pan Figure 1 2 item 7 to lower row of holes on main brackets but do not tighten the hardware yet With pan positioned between the main bracket panels from the rear raise it to align the holes as needed U se item 19 hardware in four places on each bracket Usethe item 16 17 18 hardware to fasten each side of the pan to the vertical channel 2 pls Figure 1 2 Seismic Rack Installation Chapter 1 15 Addendum to D Class Enterprise Servers System Installation Guide Installation 8 Using item 16 screws only attach the bezel mount brackets items 5 6 in Figure 1 3 to the vertical rails as shown Attach the two clip on receptacles item 30 at the bottom of the brackets as shown 9 For full GR 63 CORE NEBS compliance attach only the two bezel clips at the top of the brackets using item 29 screws Optionally attach two clips at the bottom as well 10 Attach
10. ind die Ergebnisse von Typpr fungen an Ger tekonfigurationen mit den h chsten Ger uschemissionen 8 Plattenlaufwerke Alle andere Konfigurationen haben geringere Ger uschpegel Fur weitere Angaben siehe unter Umgebungsbedingungen 28 Appendix A Regulatory Safety Statements EMC Regulatory EMC Regulatory EMC Certification prEN 55024 2 prEN 55024 3 prEN 55024 4 For USA FCC Class A part 15 For Europe CISPR 22 Level A For J apan VCCI Class A EMC Labels CE MarkFCC Statement Canadian EMC Statement Japanese VCCI Statement Safety Safety Certification UL 1950 2nd Edition CSA 22 2 No 950 93 IEC 950 1991 2nd Edition Am 1 and Am 2 EMOKO TUE 74 DK203 TUV EN60950 1992 2nd Edition SS EN 60950 EMKO TSE 74 SEC 203 93 SSIFS 1980 2 or SS EN 60825 EN 60950 1992 2nd Edition Am 1 and Am 2 Safety Labels UL Mark listed UL Mark recognized for component CSA Mark TUV GS Mark Appendix A 29 Regulatory Safety Statements EMC Regulatory DECLARATION OF CONFORMITY according to ISO IEC Guide 22 and EN 45104 Manufacturers Name Hewlett Packard Company Manufacturer s Address 8000 Foothills Blvd Roseville CA 95747 USA declares that the product Product Name PA RISC Computer System Model Numbers HP 9000 Models Dxyz x y z is any number 0 9 and Z76xy x y is any number from 0 to 9 Product Options All conforms to the following Product Specifications Safety IEC950 1
11. isconnect the input to power supply 2 Make sure that all central office safety precautions are carefully observed when connecting the power supply to primary power source 3 This product is to be installed only in Restricted Access Areas dedicated equipment rooms equipment closets or the like in accordance with Articles 110 16 to 110 18 of National Electrical Code ANSI NFFA 70 22 Chapter1 NOTE Figure 1 7 WARNING Addendum to D Class Enterprise Servers System Installation Guide DC Power Supply To protect the equipment from overload or short circuits that may cause equipment damage or fire the power supply is fused internally For added safety and integrity in the Central Office the circuit which connects to power supply should be protected with a 30 Amp over current fuse DC Power Cable Pin Diagram Safety Grounding Procedures Connect an earth ground cable to the grounding stud provided on the power supply chassis Attach the cable to the stud using the lockwasher and nut provided Preferably use at least a 10 AWG cable with a round eyelet crimp lug The computer system should at all times be connected to chassis ground The stud has been provided near the input power connector for this purpose Failure to connect an earth ground wire to the ground stud on the computer system will in essence leave the chassis floating which could be hazardous to an operator because
12. of the potential of electric shock Chapter 1 23 Table 1 3 Addendum to D Class Enterprise Servers System Installation Guide DC Power Supply Specifications DC Power Specifications Specification Data Input 48V 20A max under full load 60V Shutdown Thresholds 72V input over voltage 40V input under voltage Power 650W Outputs remote sense provided 3 3V 25A maximum SV 55A maximum 12 V 10A maximum Aux5V 55A maximum Temperature Ranges Operating Non operating Short term Operating 5 to 40 C 41 to 104 F 40 to 45 C 40 to 113 F 5 to 50 C 23 to 122 F Remote switched ground RESET signal 48V 50mA minimum 500mA maximum Alarm signals Input out of tolerance Output out of tolerance Dry relay contact closure for all alarms Fused circuits Power Input Not field replaceable 30A Replacement Power Supply To order a replacement DC Power Supply order replacement part number Z7634 67003 24 Chapter 1 A Regulatory Safety Statements 25 Regulatory Safety Statements FCC Statement USA Only FCC Statement USA Only The Federal Communications Commission in 47 CFR 15 105 has specified that the following notice be brought to the attention of the users of this product This equipment has been tested and found to comply with thelimits for a Class A digital device pursuant
13. ontrol input which can be used to turn off the power supply for the purposes of resetting the computer system Connections The DC Power Supply comes with a 9 pin Universal Mate N Lock connector for power alarm and control circuits A mating 9 pin plug with a 15 foot cable is supplied with the unit The other end of the cable is bare wire to be connected to the battery plant on the site The power wire assembly has been evaluated for use as internal wire only and therefore needs to be installed in a cabinet for the system to retain its safety regulatory markings Chapier 1 21 Table 1 2 Addendum to D Class Enterprise Servers System Installation Guide DC Power Supply Table 1 2 shows the pinouts for the site end of this cable Figure 1 5 shows a diagram of the pins The user installer must make connections to the site installation using this information Connect the 9 pin connector on the supplied cable to the negative 48 60 volt power supply at the rear of the system chassis DC Power Cable Pinouts Function Color Pin No 48V 14 AWG Black 1 Power Supply Status Open OK White 2 Shield 3 48V 14 AWG Black 4 Fan Status Open OK Red 5 Alarm Common Green 6 48V RTN 14 AWG Red 7 48V RTN 14 AWG Red 8 Remote Reset Close reset Black 9 WARNING 1 The power supply cable is used as the main disconnect device for this equipment The key switch on front of SPU does NOT d
14. pment in a rack should be such that the amount of air flow required for safe operation is not compromised Mechanical Loading Mounting of equipment in a rack should be such that no hazard exists due to uneven mechanical loading 4 Circuit Overloading Please refer to the note on page 23 5 Reliable Earthing Please refer to the topic Safety Grounding 12 Procedures on page 23 Chapter 1 Addendum to D Class Enterprise Servers System Installation Guide Installation Installation Install the seismic rack kit and the HP 9000 Series 800t D Class Server into an open relay rack using the following steps References to item numbers in these steps pertain to the item numbers listed in Table 1 1 on page 10 1 Unpack the rack mount kit and check the hardware using the parts list in Table 1 1 and the illustrations in this procedure to ensure that all the required parts are present 2 Remove the standard front bezel narrow that was shipped installed on the computer It is hinged at the top and secured by split molded posts which fit into openings in the metal work It can be removed by pulling outward at the bottom edge and lifting the top edge off the hinges 3 Remove the emblem insert and the door from the standard bezel These items will be transferred to the wide bezel in a later step e The molded plastic emblem insert has three tapered split post protrusions on the back which insert into matching holes on the co
15. the bezel support item 8 to lower area of vertical rails using item 16 screws only as shown Top edge of bezel support is flush with bottom of bezel mount brackets 11 Position top cover item 1 in upper area as shown Install but don t tighten screws Figure 1 3 Seismic Rack Installation 16 Chapter 1 NOTE Addendum to D Class Enterprise Servers System Installation Guide Installation 12 Attach cable retractor item 26 Figure 1 3 to right main bracket as shown 13 Attach the slide assemblies to the main brackets using the top row of holes abovethe base pan Do not tighten the hardware items 20 21 yet These two assemblies are mirror image ensure that they are oriented as shown 14 Position the base pan installed in step 6 to support the slides by exerting forceful upward pressure on the base pan then secure all fasteners including on the slides 15 Extend slides until they lock and position the mounting tray Figure 1 4 item 13 tothe front extensions as shown Engage alignment pins for proper location and secure with item 19 hardware Test for proper installation by sliding to full extent of travel in and out Slide release buttons are on sides of slide channels near front Chapter 1 17 Addendum to D Class Enterprise Servers System Installation Guide Installation Figure 1 4 Seismic Rack Installation WARNING The HP 9000 D Class Enterprise Server weighs about 49 5 kg
16. this printing history page Also the update may contain write in instructions Each reprinting of this manual will incorporate all past updates however no new information will be added Thus the reprinted copy will be identical in content to prior printings of the same edition with its user inserted update information New editions of this manual will contain new information as well as all updates Printing History First Edition May 1997 Second Edition May 1998 Third Edition February 2000 About This Manual TheHP 9000 family of products embraces the D Class Enterprise Server line which includes Series 800t a NEBS compatible version This document explains how to install the seismic rack and DC power supply which provide NEBS compatibility for the system Contents Addendum to D Class Enterprise Servers System Installation Guide ContentSin i sae nr ie deu da 8 Purpose of this Addendum 9 T ols N geded rota cta ER Ar ia EE a 9 SEISMIC RaKk Kit ersi ven Fea eae eed 10 Site Hazard Considerations 12 Installations ooo tee coca 0 aes wn Dee en ee 13 DG Power Supply ss seca es aa Ge AeA a ea deere eed 21 CONNOR aaah nent ae 21 Safety Grounding Procedures 23 Specifications ess iia Se aa ei dae PS 24 Replacement Power Supply 24 Regulatory Safety Statements FCC Statement USA Only
17. tions radio lectriques mis d finis dans la norme europ enne EN 55022 concernant la Compatibilit Electromagn tique Cher Client Conform ment la R glementation Fran aise en vigueur l installation ou le transfert d installation et l exploitation de cet appareil de classe A doivent faire l objet d une d claration en deux exemplaires simultan ment aupr s des services suivants Comit de Coordination des T l communications 20 avenue de S gur 75700 PARIS Pr fecture du d partement du lieu d exploitation Le formulaire utiliser est disponible aupr s des pr fectures La d daration doit tre faite dans les 30 jours suivant la mise en exploitation Le non respect de cette obligation peut tre sanctionn par les peines pr vues au code des Postes et T l communications et celles indiqu es dans la loi du 31 mai 1993 susvis e Appendix A 27 Regulatory Safety Statements International Arr t du 27 Mars 1993 publi au J O du 28 Mars ATI Product Noise Declaration Germany Only Acoustic Noise Emissions LpA 57 dB At bystander position per ISO 7779 All data arethe results from type tests of the product configuration having the highest acoustic emissions 8 disk drives All other configurations have lower emission levels Refer to the environmental specification section of the manual for details Ger uschemission LpA 57 dB Amfiktiven Arbeitsplatz nach DIN 45635 T 19 Die Daten s
18. ver and spread apart when inserted to provide an interference fit A convenient tool for compressing the split retainers is a pair of needle nose pliers Start at one end and push out on the emblem insert as you compress each split post retainer from the rear e Theplastic door is pivoted in each corner on its left edge Open the door and flex it carefully forming a slight bow near the center on the inside edge to pop the molded plastic pin on the bezel out of the molded socket on the bottom of the door See Figure 1 1 on page 14 4 Tolocate the position within the rack for installing the seismic rack kit allow 5 8 in above the top most hole in the vertical channels needed for attaching the main bracket panels For example to install the kit so that the top edge of its front bezel is flush with the bottom edge of existing equipment in the rack measure 5 8 in below that bottom edge and note the corresponding hole in the vertical channel Chapter 1 13 Addendum to D Class Enterprise Servers System Installation Guide Installation Figure 1 1 Seismic Rack Installation STD BEZEL REMOVE RET AIN Ae as a eat EMBLEM INSERT REINSTALLED ON WIDE BEZEL DOOR REINSTALLED ON WIDE BEZEL ES VANS NN ee de e def D Class Server DER ET AAA AAA AAA 5 Attach theright and left main bracket panels items 2 3 in Figure 1 2 on page 15 tothe vertical mounting rails of the relay rack usin

Download Pdf Manuals

image

Related Search

Related Contents

Digitus PCI Serial interface card  Axis P3346-VE    AS 1300 / AS 1300 Pro  安全データシート - ユシロ化学工業  Page 1 votre boite mail universitaire I "dm CROUS centre ville I)_  Operating Instructions FRIAMAT® XL  取扱説明書/399KB  Emerson 912 Series Pressure Reducing Regulators for LP-Gas Service Instruction Manual  Manual del Propietario  