1. Fresh air damper s 2 Channel Telephone access module 4 Channel Telephone access module Part number W8735D1017 Bypass flow through or steam humidifier Part number HE265A1007 UV air purifica Part number UV100E1043 Cover plate coococcnncnnicnnnnnnannncn nan nnn crac nac cnn crac Part number 32003796 001 Use to cover marks left by old thermostats Part number HR200B1005 Part number EARD6 Part number W8735D1009 Contact your dealer or Honeywell rep for a complete list of compatible products 69 1816EFS 03 8 as Honeywell Guide d installation FN VisionPRO IAQ Thermostat programmable a cran tactile ENERGY Pour installations comportant 4 circuits de chauffage 2 circuits de climatisation avec Honeywell THM5421C ou quivalent Il est imp ratif de faire r aliser l installation par un technicien chevronn Lisez attentivement les pr sentes consignes La non observation de celles ci risque d endommager le produit ou de pr senter des dangers MISE EN GARDE RISQUE DE CHOC LECTRIQUE Peut causer un choc lectrique ou endommager l quipement Couper l alimentation avant de commencer l installation mande qui contient du mercure dans un tube scell ne pas jeter la vieille commande aux ordures Consulter l administration locale de gestion des d chets pour conna tre les instructions relatives au recyclage et l limination Ce thermos
2. 0510 0520 0530 0540 0580 0600 0610 0640 0650 0660 0670 0680 0690 0700 Le message de rappel de remplacement du tampon de l humidificateur sera affich Rappel de filtre de four changer Options d alerte de filtre de four Rappel de changement du tampon de l humidificateur Rappel de changement de lampe UV Adaptive Intelligent Recovery Plages de programme Protection compresseur Limites de la tem p rature de chauff Limites de la tem p rature de clim Format horloge Prolongation de ven tilation chauff Prolongation de ventilation clim Verrouillage du clavier Commande de la temp rature de chauffage Commande de la temp rature de cli matisation Ecart de l affichage de temp rature E 0 1 2 3 4 5 6 0d DB On DOM OnN om o0 60 12 24 O SN OAN NSO Auto Discover arrangement automatique Arr t 7 270 jours de fonctionnement 10 jours de fonctionnement 8 365 jours de fonctionnement 30 jours de fonctionnement 9 30 jours de calendrier 60 jours de fonctionnement 10 60 jours de calendrier 90 jours de fonctionnement 11 90 jours de calendrier 120 jours de fonctionnement 12 180 jours de fonctionnement 120 jours de calendrier 13 180 jours de calendrier 14 365 jours de calendrier Le temporisateur compte le temps d ex cution de Heat Cool Le temporisateur compte le temps d ex cution de Cool seulement Auto Di
3. Auto Discover Other options 1 to 12 CPH Auto Discover Other options 1 to 12 CPH Auto Discover Other options 1 to 12 CPH Backlight on for approx 45 seconds after keypress Backlight always on low intensity full bright after keypress Manual User options Heat Cool Off Automatic User options Heat Cool Auto Off System selects heat cool based on indoor temp Heat cool settings 3 F apart 1 5 C Other options 2 9 2 F to 9 F 1 C to 5 C Fahrenheit Celsius Auto change to daylight savings time 2007 and beyond for areas that use the new 2007 DST calendar Auto change to daylight savings time through 2006 and for areas that do not use the new 2007 DST calendar Daylight savings time is turned off Display temp at thermostat location only Display temp at indoor sensor location s Average between thermostat amp sensor location s Auto Discover None Remote sensor Balance point plus 2 F droop Balance point only Balance point Aux Heat Lockout plus 2 F droop 60 minutes Off Other options 30 45 or 75 minutes No compressor lockout Other options 5 to 60 F 15 C to 15 5 C No heat pump auxiliary lockout Other options 5 to 65 F 15 C to 18 5 C Auto Discover No Yes Internal sensor in thermostat Sensors disabled Auto Discover See page 6 3 69 1816EFS 03 Installation Guide Installer setup Setup function 0372 0
4. 6 595 430 7 012 927 7 044 397 D509151 y otras Oprima DONE para salir patentes pendientes Copyright O 2008 Honeywell International Inc Todos los derechos reservados Oprima DONE para guardar los cambios Installation Guide Configuraci n 1 Presione SYSTEM sistema 2 Oprima 5 segundos Oprima DONE para salir y 3 Cambie los ajustes guardar los ajustes vea p 18 22 ES ES Giet cu G srsten ie L L E ll DONE Funci n ge 0120 Oprima Y para cambiar Ajustes y opciones configuraci n de f brica en negritas Configuraci n Funci n 0110 N mero de zona o 1 9 0120 A o primeros 20 2 d gitos 21 0130 A o segundos 06 2 d gitos 0140 Mes 6 0150 Fecha 15 0160 Formato de horario 4 0 0165 Restaure el horario 0 Energy Star 1 0172 Tipos de sistemas 1 2 3 E 0174 Etapas del compresor 1 de refrigeraci n 0176 Etapas de calor o de 1 la bomba de calor auxiliar 0180 Ventilador calefac 0 ci n convencional 1 2 E 0190 V lvula de cambio 0 1 terminal O B 69 1816EFS 03 Sin divisi n de zona N mero de zona 2000 2099 2100 2178 2006 Otras opciones 00 99 Otras opciones 1 12 Otras opciones 1 31 programaci n de 7 d as No programable No Si Convencional Bomba de calefacci n Calor solamente ning n ventilador Auto Discover ajuste autom tico 1
5. 69 1816EFS 03 10 VisionPRO IAQ Configuration Fonctions Param tres et choix d faut usine en gras 0200 0210 0220 0230 0240 0250 0260 0280 0300 0310 0320 0330 0340 0342 0345 0346 0350 0360 0365 Chauffage auxiliaire Disp externe de combustible fossile Cycle du compres seur de tage 1 Cycle du compres seur du tage 2 Cycle de chauffe du tage 1 Cycle de chauffe du tage 2 Cycle de chauffe du tage 3 R tro clairage Changement Manuel Auto Zone morte de basculement Affichage de temp rature Changement horaire t Sonde de temp rature d int rieur Sonde de temp rature ext rieure Commande de thermopompe 2 carburant Thermopompe 2 carburant upstage au temporisateur de chaudi re Verrouillage de la thermopompe Verrouillage aux de la thermopompe Sonde de temp rature de d charge somN o o NO sa Auto Discover arrangement automatique Chauffage de secours lectrique Chauffage de secours combustible fossile External fossil fuel kit controls backup heat Commande le chauffage de secours capteur ext rieur requis Auto Discover arrangement automatique Autres choix 1 6 cycles heure Auto Discover arrangement automatique Autres choix 1 6 cycles heure Auto Discover arrangement automatique Autres choix 1 12 cycles heure Auto Discov
6. 7 012 927 7 044 397 D509151 International Inc All rights reserved 69 1816EFS 03 and other patents pending Copyright 2008 Honeywell Installation Guide Installer setup 1 Press SYSTEM 2 Press and hold for 5 seconds Press DONE to save amp exit 3 Change settings see p 2 6 TUE Inside 4 AUTO ES vied cu EE no A l DONE l 5 E CANCEL Function Setting ne De De pu AR SCHED HOLD DONE Press Y to change Installer setup Setup function Settings amp options factory default in bold 0110 Zone number O Not zoned 1 9 Zone number 0120 Year 20 2000 2099 first two digits 21 2100 2178 0130 Year 06 2006 second two digits Other options 00 99 0140 Month 6 Other options 1 12 0150 Date 15 Other options 1 31 0160 Schedule format 4 7 day programming 0 Non programmable 0165 Restore Energy 0 No Star schedule 1 Yes 0172 System type 1 Conventional 2 Heat pump 3 Heat only no fan E Auto Discover 0174 Cooling compressor 1 1 stage of cool stages Other options 0 or 2 stages or E 0176 Heat or Heat Pump 1 1 stage of heat Aux stages Other options 0 2 or 3 stages or El 0180 Fan control conventional heat Gas Oil heat equipment controls heating fan Electric furnace
7. Pas de verrouillage auxiliaire de la thermopompe Autres choix 15 C 18 5 C 5 65 F Auto Discover arrangement automatique Non Oui Voir la page 14 11 69 1816EFS 03 Installation Guide Configuration Fonctions Param tres et choix d faut usine en gras 0370 0372 0374 0379 0383 0384 0390 0391 0392 0393 0394 0400 0401 0402 0403 0404 0405 0406 Sonde d int rieur d humidit Commande d humidification d humidificateur Commande de 1 0 E E 0 1 3 Action de ventilateur O 1 2 3 0 d shumidification 1 3 3 Surrefroidissement de la limite Action de ventilateur O de d shumidification 1 Mode de maison vide O Maison vide o ventilateur 1 2 Maison vide basse 76 temp rature limite Maison vide 85 temp rature Maison vide 65 d shumidification Ventilation o 1 2 Nombre de chambres 2 coucher Taille de maison 10 Niveau de ventilation 160 Limite maximale de 50 ventilation F Action de ventilateur 1 69 1816EFS 03 Sonde interne dans le thermostat Les sondes ont neutralis Auto Discover arrangement automatique Auto Discover arrangement automatique Aucun Humidifiez aucun antigel Humidifiez avec antigel Humidifiez seulement quand le ventilateur ou la chaleur est activ L humidificateur force le ventilateur dessus Humidifiez seulement quand la chaleur est allum e L h
8. configuradas en E Auto Discover se configurar n de manera autom tica seg n la informaci n enviada desde el equipo conectado Cuando utilice la funci n Auto Discover descubrimiento autom tico verifique que el valor descubierto sea el correcto Si no es correcto el equipo no est transmitiendo la informaci n y deber cambiar las configuraciones manualmente Adaptive Intelligent Recovery Funci n 0530 Permite que el termostato aprenda cu nto tiempo les lleva a la estufa y al acondicionador de aire alcanzar la temperatura programada de modo que se alcance la temperatura a la hora fijada Protecci n del compresor Funci n 0580 Fuerza al compresor a esperar unos minutos antes de volver a encenderse para prevenir da os Durante este tiempo el mensaje Wait titila en la pantalla Control meridional de la deshumidificaci n Funciones 0390 0394 Esta caracter stica es til para los hogares en climas meridionales Permite control de la humedad cuando el casa es vacante durante la estaci n caliente Usted puede controlar la temperatura funci n 0393 y la deshumidificaci n funci n 0394 mientras que la casa es vacante Usted puede controlar humedad con un deshumidificador o un sistema de enfriamiento funci n 0379 Si se utiliza un sistema de enfriamiento la humedad es controlada refrescando el aire de interior a la temperatura l mite baja funci n 0392 Cuando se alcanza la humedad deseada el sistema m
9. etapa de fr o Otras opciones 0 2 etapas o E 1 etapa de calor Otras opciones 0 2 6 3 etapas o El Calefacci n a gas petr leo el equipo controla el ventilador Estufa el ctrica el termostato controla el ventilador de la calefacci n El equipo controla etapa 1 el termostato controla etapa 2 Auto Discover ajuste autom tico Terminal O B controla la v lvula en refrigeraci n Terminal O B controla la v lvula en calefacci n Vea la p gina 22 18 VisionPRO IAQ Configuraci n Funci n Ajustes y opciones configuraci n de f brica en negritas 0200 0210 0220 0230 0240 0250 0260 0280 0300 0310 0320 0330 0340 0342 0345 0346 0350 0360 0365 Calor de reserva Aux amp EmHeat Juego para combus tible f sil externo Ciclo del compresor de etapa 1 Ciclo del compresor de etapa 2 Ciclo de calefacci n de etapa 1 Ciclo de calefacci n de etapa 2 Ciclo de calefacci n de etapa 3 Iluminaci n de la pantalla Cambio Manual Auto Banda muerta del cambio autom tico Pantalla de temperatura Ahorro diurno Sensor de temperatura interior Sensor de temperatura exterior Bomba de calefacci n com bustible dual Bomba de calefac ci n contador de tiempo del horno 0 1 1 0 o o 1 3 D oO 0 o 1 2 E 0 1 1 0 2 6 0 Cierre del compresor 0 de la bomba de calefacci n Cie
10. fonctionne Entre ces temp ratures les deux sources de chaleur fonctionnent Commande de la thermopompe secours de combustible fossile fonction 0345 Option 0 point d quilibre seulement Si ext rieur la temp rature est au dessus de point d quilibre fonction 0350 seulement le compresseur fonctionne Au dessous de cette temp rature seulement la chaleur de secours fonctionne Option 1 point d quilibre abattemen 2 F Comme pr c demment mais la chaleur de secours est activ e si la temp rature ambiante chute par 2 F le compresseur est mis hors tension Option 2 point d quilibre Aux Heat abattemen 2 F Le compresseur fonctionne seulement au dessus de la temp rature auxiliaire de verrouillage travaux de secours de la chaleur seulement au dessous du point d quilibre l abattemen 2 F entre les temp ratures Si la temp rature n est pas atteinte dans un temps raisonnable placez le temporisateur fonction 0346 Apr s le temps indiqu le compresseur sera mis hors tension et le syst me commutera la chaleur de secours Commande De Ventilation Fonctions 0400 0406 S il y a une unit ind pendante de ventilation vous pouvez a rer la maison sur demande fonction 0400 La maison peut tre a r e automatiquement si le humidit lev est d tect tandis que la chaleur est allum e fonction 0406 69 1816EFS 03 14 VisionPRO IAQ Essai du systeme Pendant la config
11. syst me par l installateur Le mode de test par l installateur fait partie du menu de configuration par l installateur 1 Passer au test du syst me par l installateur 3 Voir ci dessus pour conna tre les tests offerts en entrant dans le menu de configuration par l installateur 4 Si l installation comporte un capteur de temp rature de l air de soufflage CTAS 2 Les tests figurent la fin des param tres ISU365 1 appuyer sur MORE pour observer d installation la temp rature de l air de soufflage et sur CANCEL pour revenir l cran des tests 15 69 1816EFS 03 Installation Guide 027 Le thermostat est d fectueux doit tre remplac 035 D tection de deux zones de thermostat 036 Deux temporisateurs UV ont d tect 037 Deux temporisateurs de filtre ont d tect 038 Deux temporisateurs d humidificateur ont d tect 039 Deux senseurs d humidit ont d tect 040 Le compresseur devrait tre activ mais il n est pas 050 Deux sondes de temp rature ext rieures 052 La sonde de d charge d air est d fectueuse 053 La sonde de temp rature ext rieure est d fectueuse 054 La sonde d int rieur d humidit est d fectueuse 089 L quipement est absent chauffage ou refroidissement 090 L interface de donn es est toujours occup e 091 Le thermostat ne re oit pas des donn es de l autre quipement 118 La sonde de temp rature de l air de d charge est d fectueuse 119 La sonde de temp rature est d f
12. 374 0379 0383 0384 0390 0391 0392 0393 0394 0400 0401 0402 0403 0404 0405 0406 0500 Indoor humidifica tion control Humidifier fan action Dehumidification control Over cooling limit Dehumidification fan action Dehumidification away mode Dehum away mode fan setting Dehum away mode low limit temp Dehum away mode temp setting Away dehumidifica tion setting Ventilation control Number of bedrooms Size of house Ventilation level Max ventilation limit Ventilation fan action Ventilation in high humidity Furnace filter change alert 69 1816EFS 03 Settings amp options factory default in bold Auto Discover Off Humidify no frost protection Humidify with frost protection E 0 1 3 o Humidify only while fan or heat is on 1 Humidify forces fan on 2 Humidify only when heat is on 3 Humidifier operates independent of fan o 1 3 3 No dehumidification control Dehumidify with air conditioner Whole house dehumidifier 3 F 1 5 C Other options 1 2 1 F or 2 F 0 5 C to 1 5 C System fan turns on with dehumidifier Dehumidifier operates independent of fan 0 1 o No 1 Yes o Fan auto 1 2 Fan always on Fan circulate 76 Low limit temperature 76 F 24 C Other options 70 F to 80 F 21 C to 27 C 85 Away temperature 85 F 29 C Other options 70 F to 99 F 21 C to 37 C 65
13. Away humidity level 65 Other options 55 to 70 o No ventilation 1 Ventilation always allowed 2 Ventilation not allowed during sleep period 2 Two bedrooms Other options 1 to 6 10 1 000 square feet Other options 11 to 50 1 100 to 5 000 square feet 160 CFM cubic feet per minute Other options 30 to 195 CFM 50 50 ventilation limit Other options 30 to 60 or 100 P Meets ASHRAE 62 2 standard F Does not meet ASHRAE 62 2 standard 1 Ventilation on forces fan on 2 Ventilation does not force fan on 1 On heat mode only 0 Off E Auto Discover 7 270 day run time 0 Off 8 365 day run time 1 10 day run time 9 30 calendar days 2 30 day run time 10 60 calendar days 3 60 day run time 11 90 calendar days 4 90 day run time 12 120 calendar days 5 120 day run time 13 180 calendar days 6 180 day run time 14 365 calendar days See page 6 VisionPRO IAQ Installer setup Setup function Settings amp options factory default in bold 0502 0510 0520 0530 0540 0580 0600 0610 0640 0650 0660 0670 0680 0690 0700 0701 0710 Humidifier Pad replacement will be displayed in the user interface as run Furnace filter alert options Humidifier pad change alert UV lamp change alert Adaptive Intelligent Recovery Program periods Compressor off time min Heat temperature range stop Cool temperature range stop Clock format Ext
14. Honeywell Installation Guide VisionPRO AQ Touch screen Programmable Thermostat For up to 4 Heat 2 Cool systems with Honeywell THM5421C or equivalent Must be installed by a trained experienced technician Read these instructions carefully Failure to follow these instructions can damage the product or cause a hazardous condition CAUTION ELECTRICAL HAZARD Can cause electrical shock or equipment damage A Disconnect power before beginning installation sealed tube do not place the old control in the trash Contact your local waste manage ment authority for instructions regarding recycling and proper disposal This thermostat contains a Lithium battery which may contain Perchlorate material Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate A MERCURY NOTICE If this product is replacing a control that contains mercury in a Installation Thermostat can be mounted on 2 x 4 J box or on drywall or plaster using included wall anchors drill 3 16 holes for drywall 7 32 holes for plaster Connect 1 2 3 terminals on thermostat to 1 2 3 terminals on EIM or Zone Panel see EIM or Zone Panel Installation Guide for wiring diagrams Set date time Date Time TUE Month a Dm Year v m LJ Y Press DONE to save changes Press DONE to exit X U S Registered Trademark US Patent No 6 208 263 6 373 376 6 448 901 6 595 430
15. a pi ce est plus fra che que la temp rature r gl e Choisissez si la pi ce n atteint pas la temp rature r gl e Le thermostat affiche le temp rature r elle de la pi ce Autres choix 1 5 C 1 5 C 3 F 3 F Voir la page 14 en nombre de jours de fonctionnement l interface utilisateur si le param tre ISU 372 est r gl 1 ou 3 et en jours civils si ce param tre est r gl 0 13 69 1816EFS 03 Installation Guide Configuration Fonctions Param tres et choix d faut usine en gras 0701 cart de l affichage 0 Le thermostat affiche le humidit r elle de la pi ce de humidit Autres choix 5 5 0710 R TABLISSEMENT 0 Pas de r tablissement 1 Remettre les choix d installation et le programme au d faut d usine seuls les r glages de date et d heure sont conserv s Fonctions sp ciales Auto Discover Les fonctions de figuration r gl es E auto d couverte seront configur es automatiquement en fonction de l information transmise par le mat riel raccord En mode auto d couverte il faut s assurer que la valeur inscrite par le syst me est exacte Si tel n est pas le cas le mat riel ne transmet pas l information et il faut modifier les param tres manuellement Adaptive Intelligent Recovery Rattrapage intelligent fonction 0530 Elle permet au thermostat d apprendre combien de temps il faut la chaudi re et au climatiseur pour atte
16. anda de calor Apagado Otras opciones El ventilador funciona durante 30 60 90 o 120 segundos despu s de terminada la demanda de fr o Teclado desbloqueado totalmente funcional Parcialmente bloqueado s lo acceso a ajustes de temperatura Completamente bloqueado Control de temperatura normal recomendado Elija si el cuarto es m s caliente que temperatura se alada Elija si el cuarto no alcanza la temperatura se alada Control de temperatura normal recomendado Elija si el sitio est m s fresco que temperatura se alada Elija si el cuarto no alcanza la temperatura se alada El termostato muestra la temperatura real de la habitaci n Otras opciones 3 F a 3 F ajuste 1 5 C a 1 5 C El termostato muestra la humedad real de la habitaci n Otras opciones 5 a 5 ajuste El reemplazo de la almohadilla del humidificador se mostrar en la interfaz Vea la p gina 22 del usuario como d as de funcionamiento si ISU 372 est configurado en 1 6 3 y como d as calendario si ISU 372 est configurado en 0 21 69 1816EFS 03 Installation Guide Funci n Ajustes y opciones configuraci n de f brica en negritas 0710 REAJUSTE O Sin reconfiguraci n 1 Reconfigure las opciones y el horario de programa del instalador al original de f brica s lo se conservan los ajustes de fecha y hora Funciones especiales Auto Discover descubrimiento autom tico Las funciones de la configuraci n que est n
17. antendr la temperatura usted selecto en la funci n 0393 Control de la bomba de calefacci n reserva el ctrica del calor Funciones 0350 0360 Si hay un sensor de temperatura exterior seleccione una temperatura del cierre del compresor funci n 0350 Debajo de esta temperatura solamente el calor el ctrico funciona Tambi n seleccione una temperatura auxiliar del cierre funci n 0360 Sobre esta temperatura solamente el compresor funciona Entre estas temperaturas ambas fuentes de calor funcionan Control de la bomba de calefacci n reserva combustible f sil del calor Funcione 0345 Opci n 0 punto del balance solamente Si la temperatura exterior est sobre el punto del balance funci n 0350 s lo el compresor funciona Debajo de esta temperatura solamente el calor de reserva funciona Opci n 1 punto del balance inclinaci n 2 F Como arriba solamente se activa el calor de reserva si la temperatura ambiente cae por 2 F se desactiva el compresor Opci n 2 punto del balance AuxHeat inclinaci n 2 F El compresor funciona solamente sobre la temperatura auxiliar del cierre trabajos de reserva del calor solamente debajo del punto del balance inclinaci n 2 F entre las temperaturas Si la temperatura no se alcanza en un rato razonable fije el contador de tiempo funci n 0346 Despu s del tiempo se alado el compresor ser desactivado y el sistema cambiar al calor de reserva Control De la Ven
18. atura exterior es defectuoso 054 El sensor de interior de la humedad es defectuoso 089 El equipo falta calefacci n o el refrescarse 090 El interfaz de los datos est siempre ocupado 091 El term stato no est recibiendo datos del otro equipo 118 El sensor de temperatura del aire de la descarga es defectuoso 119 El sensor de temperatura es defectuoso 121 Dos sensores de la descarga del aire detectaron Accesorios Comun quese con su distribuidor para encargar piezas de repuesto Sensor de temperatura ext riOr iiennn N mero de pieza C7089U1006 Sensor remoto de temperatura interior N mero de pieza C7189U1005 Sensor de temp del aire de la descarga N mero de pieza C7835A1009 Ventilador de la recuperaci n de la energ a N mero de pieza ER200B2006 Ventilador de la recuperaci n del calor N mero de pieza HR200B1005 Apagador del aire fresco N mero de pieza EARD6 M dulo de acceso telef nico de 2 canales N mero de pieza W8735D1009 M dulo de acceso telef nico de 4 canales N mero de pieza W8735D1017 Humidificador desviador de flujo o humidificador de vapor N mero de pieza HE265A1007 Purificador UV del aire 53ssretstiinirmnnsenscernanseness N mero de pieza UV100E1043 Cubierta cncmoccniccannnnnnes N mero de pieza 32003796 001 Para cubrir marcas dejadas por otros termostatos P ngase en contacto con su distrib
19. ba de la EmHeat etapas 1 2 5 Humidificador 0 Apagado PRECAUCI N RIESGO DE DA OS 1 Encendido AL EQUIPO Durante las pruebas se its suspende la protecci n del compresor 6 Deshumidificador 0 Apagado Para evitar dafios al equipo evite ciclar el 1 Encendido Fu compresor demasiado r pido 7 Ventilador 0 Apagado 1 Encendido C mo usar la Prueba del sistema La Prueba del sistema es parte del Men de configuraci n de instalaci n 1 Para ingresar en la Prueba del sistema 4 ingrese en la configuraci n de instalaci n 2 Tenga en cuenta que la prueba aparece al final de los N meros de la configuraci n de instalaci n 3 Vea arriba las Pruebas del sistema disponibles C digos de error El term stato es defectuoso debe ser substituido 027 035 036 037 038 039 040 050 052 Se detect el termostato de la zona duplicada Dos contadores de tiempo UV detectados Dos contadores de tiempo del filtro detectaron Dos sensores de la humedad detectaron El compresor debe ser activado pero no es Dos sensores de temperatura exterior El sensor de la descarga del aire es defectuoso 23 Si est instalado con el Sensor de temperatura de aire de descarga ISU365 1 presione MORE m s para visualizar la temperatura de descarga y presione CANCEL cancelar para volver a la pantalla de prueba Dos contadores de tiempo del humectador detectaron 69 1816EFS 03 C digos de error 053 El sensor de temper
20. cooler than set temperature Choose if room does not reach set temperature Thermostat displays actual room temperature Other options 3 F to 3 F offset 1 5 C to 1 5 C Thermostat displays actual room humidity Other options 5 to 5 offset No reset Reset installer options amp program schedule to factory default only date and time settings are retained See page 6 time days if ISU 372 is set to 1 or 3 and calendar days if ISU 372 is set to 0 5 69 1816EFS 03 Installation Guide Special function Auto Discover Setup functions set to E Auto Discover will be configured automatically based on information sent from connected equipment When using Auto Discover verify that the discovered value is correct If it is not the equipment is not communicating the information and you must change settings manually Adaptive Intelligent Recovery Setup Function 0530 Allows the thermostat to learn how long the furnace and air conditioner take to reach programmed temperature settings so the temperature is reached at the scheduled time Compressor Protection Setup Function 0580 Forces the compressor to wait a few minutes before restarting to prevent damage During this time the message Wait flashes on the display Southern Away Dehumidification Control Setup Functions 0390 0394 This feature is useful for homes in southern climates It allows humidity control when the the home is unoccupied fo
21. e Installer Setup Menu 1 Enter the Installer System Test by entering 3 See above for available Installer System Installer Setup Tests 2 The test appears at the end of the Installer 4 If installed with a Discharge Air Setup Numbers Temperature Sensor ISU365 1 press MORE to view the discharge temperature and press CANCEL to return to the Installer test screen 7 69 1816EFS 03 Installation Guide Error codes 027 Faulty thermostat must be replaced 035 Duplicate thermostat zone detected 036 Duplicate UV timer 037 Duplicate filter timer 038 Duplicate humidifier pad timer 039 Duplicate indoor humidity sensor 040 Compressor should be running but it is not 050 Duplicate outdoor temperature sensor 052 Faulty post coil air discharge sensor 053 Faulty outdoor temperature sensor 054 Faulty indoor humidity sensor 089 Heating cooling equipment is missing 090 Data interface is continuously busy 091 Thermostat is not receiving data from other equipment 118 Faulty discharge air temperature sensor 119 Faulty temperature sensor 121 Duplicate post coil air discharge sensor Accessories Please contact your distributor to order replacement parts Outdoor temperature sensor Part number C7089U1006 Remote indoor temperature sensor Part number C7189U1005 Discharge air temp sensor Part number C7835A1009 Energy recovery ventilator Part number ER200B2006 Heat recovery ventilator
22. ectueuse 121 Deux sondes de d charge d air ont d tect Accessoires Veuillez contacter votre distributeur pour commander des pi ces de rechange Capteur de temp rature ext rieure oooocccnccnnincncncnnccnncnnnennnnnnnnnn Num ro de la pi ce C7089U1006 Capteur distance de temp rature int rieure Num ro de la pi ce C7189U1005 Sonde de air temp rature de d charge ococcnnccccanccancnncnanennnnnnannnas Num ro de la pi ce C7835A1009 Ventilateur de r tablissement d nergie Num ro de la pi ce ER200B2006 Ventilateur de r tablissement de la chaleur Amortisseur d air frais mi Module d acc s t l phonique 2 voies Num ro de la pi ce W8735D1009 Module d acc s t l phonique 4 voies Num ro de la pi ce W8735D1017 Humidificateur d rivation et passage direct ou vapeur Num ro de la pi ce HE265A1007 Eptirateut UVA Mica a Num ro de la pi ce UV100E1043 Cache trou Num ro de la pi ce 32003796 001 Sert dissimuler les marques laiss es par d anciens thermostats Num ro de la pi ce HR200B1005 Num ro de la pi ce EARD6 Communiquez avec votre repr sentant Honeywell pour obtenir la liste compl te des produits compatibles 69 1816EFS 03 16 as Honeywell Gu a de instalaci n FN VisionPRO IAQ Termostato programable sensible al tacto ENERGY Para hasta 4 sistemas de calefacci n 2 de refrigeraci n con Honeywell THM5421C o equivalen
23. ended fan timer heat Extended fan timer cool Keypad lock Heat temperature control Cool temperature control Temperature display offset Humidity display offset RESET o 1 E 0 1 2 3 E 0 1 2 1 0 4 2 5 60 12 24 O ON ON NSO Timer counts Heat amp Cool run time Timer counts Cool run time only Auto Discover Off 90 calendar days or 30 days run time 180 calendar days or 60 days run time 365 calendar days or 90 days run time Auto Discover Off 365 calendar days 1 year 730 calendar days 2 years On k Off 4 program periods Wake Leave Return Sleep 2 program periods Wake Sleep 5 minute compressor off time Other options 0 to 4 minutes Max heat temperature setting is 90 F 32 C Other options 40 to 90 F 4 C to 32 C Min cool temperature setting is 60 F 15 C Other options 60 99 F 15 C to 37 C 12 hour time i e 3 30 pm 24 hour time i e 15 30 Off Other options Fan runs for 30 60 90 or 120 seconds after call for heating ends Off Other options Fan runs for 30 60 90 or 120 seconds after call for cooling ends Keypad unlocked fully functional Partially locked access to temperature settings only Fully locked Standard temperature control recommended Choose if room is warmer than set temperature Choose if room does not reach set temperature Standard temperature control recommended Choose if room is
24. er arrangement automatique Autres choix 1 12 cycles heure Auto Discover arrangement automatique Autres choix 1 12 cycles heure R tro clarage allum pendant env 45 secondes apr s utili sation R tro clairage toujours sur faible intensit plein clairage apr s utilisation du clavier Manuel Options d utilisateur Heat Cool Off Automatique Options d utilisateur Heat Cool Auto Off Le syst me choisit heat cool bas sur la temp rature d int rieur cart de 1 5 C 3 F Temp rature chauffage clim Autres choix 2 9 1 C 5 C 2 F 9 F Fahrenheit Celsius Changement automatique horaire d t 2007 et au del pour les zones qui utilisent le nouveau calendrier HE 2007 Changement automatique horaire d t jusqu 2006 et pour les zones qui n utilisent pas le nouveau calendrier HE 2007 L horaire t est d sactiv Mesure de la temp rature l endroit de thermostat seulement Mesure de la temp rature aux endroits d int rieur de sonde La temp rature moyenne de tous les endroits Auto Discover arrangement automatique Aucun Sonde distance Point d quilibre plus l abattemen 2 F Point d quilibre seulement Point d quilibre Aux Heat Lockout plus l abattemen 2 F 60 minutes Aucun Autres choix 30 45 ou 75 minutes Pas de verrouillage du compresseur de la thermopompe Autres choix 15 C 15 5 C 5 60 F
25. ersten a Fonction 5 A gien DONE SJ Giet cu LL a nl 5 4 pra Arrangement ei op Appuyez A W pour changer Configuration Fonctions 0110 Nombre de zones O Aucune 1 9 Nombre de zones 0120 Ann e deux 20 2000 2099 premiers chiffres 21 2100 2178 0130 Ann e deux 06 2006 derniers chiffres Autres choix 00 99 0140 Mois Autres choix 1 12 0150 Date 0160 Format du programme 5 Autres choix 1 31 Programmation 7 jours Non programmable 6 1 4 0 0165 Programme du O Non d faut Energy Star 1 Oui 1 2 3 E 1 Typique Thermopompe La chaleur seulement aucun ventilateur Auto Discover arrangement automatique 0172 Type d installation 0174 tages de compres 1 tage de refroidissement seur de refroid Autres choix 0 2 ou E 0176 tages auxiliaires 1 1 tage de chauffage de chauffage ou de Autres choix 0 2 3 ou E thermopompe 0180 Commande de o Gaz mazout l quipement commande le ventilateur de ventilateur la chauffage Chaudi re lectrique le thermostat commande le ventilateur de chauff L quipement commande tage 1 thermostat commande tage 2 Auto Discover arrangement automatique chaleur typique Borne O B commande la valve en climatisation Borne O B commande la valve en chauffage 0190 Valve d inversion borne O B MN Voir la page 14
26. imer Function 0346 After the designated time the compressor will be deactivated and the system will switch to backup heat Ventilation Control Setup Functions 0400 0406 If the system includes a self powered ventilation unit Function 0400 the home can be ventilated on demand or ventilated automatically if high humidity is detected while in heating mode Function 0406 69 1816EFS 03 6 VisionPRO IAQ Installer system test During installer setup press W Test System repeatedly until Test appears number status Press A Vto Press A W to Press DONE to terminate testing select test change status System test System status Other messages 1 Cooling 0 Off P Ventilation meets ASHRAE 62 2 system 1 Test cooling stage 1 standard Function 0404 Test cooling stages te F Ventilation does not meet ASHRAE 2 Fan system 0 Fan off 62 2 standard Function 0404 Fanon Err See error codes 3 Heating o Off system 1 Test heating stage 1 2 Test heating stages 1 2 3 Test heating stages 1 2 3 CAUTION EQUIPMENT 4 Test heating stages 1 2 3 4 DAMAGE HAZARD Compressor 4 Emergency 0 Off protection is bypassed during heating 1 Test EmHeat stage 1 testing To prevent equipment system 2 Test EmHeat stages 1 2 damage avoid cycling the com pressor quickly 5 Humidifier 0 Off 1 On 6 Dehumidifier 0 Off 1 On 7 Ventilator 0 Off 1 On How to Use the Installer System Test The Installer Test is part of th
27. indre la temp rature pr programm e de mani re atteindre celle ci heure programm e Protection du compresseur fonction 0580 Elle force le compresseur attendre quelques minutes avant de red marrer pour ne pas endommager celui ci Pendant ce temps le message Wait clignote sur l affichage Commande de la d shumidification m ridionale fonctions 0390 0394 Ce dispositif est utile pour des maisons dans des climats m ridionaux ll commande l humidit quand la la maison est vide pendant la saison chaude Vous pouvez commander la temp rature fonction 0393 et la d shumidification fonction 0394 tandis que la maison est vide Vous pouvez commander l humidit avec un d shumidificateur ou un syst me de refroidissement fonction 0379 Si un syst me de refroidissement est employ l humidit est command e en refroidissant l air d int rieur la basse temp rature limite fonction 0392 Quand l humidit d sir e est atteinte le syst me maintiendra la temp rature vous choisi dans la fonction 0393 Commande de la thermopompe chauffage lectrique de secours fonctions 0350 0360 S il y a une sonde de temp rature ext rieure choisissez une temp rature de verrouillage de compresseur fonction 0350 Au dessous de cette temp rature seulement la chaleur lectrique fonctionne Choisissez en outre une temp rature auxiliaire de verrouillage fonction 0360 Au dessus de cette temp rature seulement le compresseur
28. o de 2 dormitorios Tama o de la casa 10 Ventilaci n 160 L mite m ximo de 50 la ventilaci n P F Acci n del ventilador 1 de ventilaci n 2 Ventilaci n en hume 1 dad alta 69 1816EFS 03 Ajustes y opciones configuraci n de f brica en negritas Sensor interno en term stato Sensores inhabilitados Auto Discover ajuste autom tico Auto Discover ajuste autom tico Apagado Humedezca ninguna protecci n de helada Humedezca con la protecci n de helada Humedezca solamente mientras que el ventilador o el calor est encendido La humectaci n activa el ventilador Humedezca solamente cuando el calor est encendido El humectador funciona la independiente del ventilador Ninguno Utilice el acondicionador de aire Utilice el deshumidificador de la casa 33 F 1 5 C Otras opciones 1 2 1 F o 2 F 0 5 C o 1 5 C El deshumidificador activa el ventilador del sistema El deshumidificador funciona la independiente del ventilador No Si Ventilador autom tico Ventilador funciona continuamente Ventilador circula el aire L mite de la temperatura 76 F 24 C Otras opciones 70 F a 80 F 21 C a 27 C Temperatura mientras que la casa es vacante 85 F 29 C Otras opciones 70 F a 99 F 21 C a 37 C Nivel de la humedad mientras que la casa es vacante 65 Otras opciones 55 a 70 Ninguna ventilaci n La ventilaci n permiti siempre Ventilaci n no permitida d
29. pantalla de humedad Auto Discover ajuste autom tico Apagado 7 270 d as de funcionamiento 10 d as de funcionamiento 8 365 d as de funcionamiento 30 d as de funcionamiento 9 30 d as de calendario 60 d as de funcionamiento 10 60 d as de calendario 90 d as de funcionamiento 11 90 d as de calendario 120 d as de funcionamiento 12 120 d as de calendario 180 d as de funcionamiento 13 180 d as de calendario 14 365 d as de calendario El contador de tiempo cuenta tiempo de pasada de Heat amp Cool El contador de tiempo cuenta tiempo de pasada de Cool solamente Auto Discover ajuste autom tico Apagado 90 d as calendarios o 30 d as de funcionamiento 180 d as calendarios o 60 d as de funcionamiento 365 d as calendarios o 90 d as de funcionamiento Auto Discover ajuste autom tico Apagado 365 d as calendarios 1 a o 730 d as calendarios 2 a os Activado Apagado 4 per odos del programa Wake Leave Return Sleep 2 per odos del programa Wake Sleep 5 minutos Otras opciones 0 a 4 minutos Temperatura de calefacci n m xima es 90 F 32 C Otras opciones 40 a 90 F 4 C a 32 C Temperatura de refrigeraci n m nima es 60 F 15 C Otras opciones 60 a 99 F 15 C a 37 C Horario de 12 horas ej 3 30 pm Horario de 24 horas ej 15 30 Apagado Otras opciones El ventilador funciona durante 30 60 90 or 120 segundos despu s de terminada la dem
30. r long periods during the hot humid season You can control temperature Function 0393 and dehumidification Function 0394 while away You can control humidity with a dehumidifier or a cooling system Function 0379 If a cooling system is used humidity is controlled by cooling indoor air to the Low Limit Temperature Function 0392 When the desired humidity is reached the system will maintain the temperature you select in Function 0393 Heat Pump Control Electric Backup Setup Functions 0350 0360 If an outdoor temperature sensor is installed select a compressor lockout temperature Function 0350 Below this temperature only electric heat operates Also select an auxiliary lockout temperature Function 0360 Above this temperature only the compressor operates Between these temperatures both heat sources operate Heat Pump Control Fossil Fuel Backup Setup Function 0345 Option O Balance point only If outdoor temperature is above balance point Function 0350 only the compressor operates Below this temperature only backup heat operates Option 1 Balance point 2 F droop As above but backup heat is activated if room temperature drops by 2 F compressor is deactivated Option 2 Balance point Aux Heat 2 F droop Compressor works only above auxiliary lockout temperature backup heat works only below balance point 2 F droop between temperatures If temperature is not reached in a reasonable time set the upstage t
31. rre de la bomba de O calefacci n auxiliar Sensor de tempera tura de la descarga E 0 1 Auto Discover arrangement automatique Calefacci n el ctrica de respaldo Calefacci n de combustible f sil de respaldo Juego de combustible f sil externo controla la calefacci n de respaldo Termostato controla la calefacci n de respaldo necesita sensor exterior Auto Discover ajuste autom tico Otras opciones 1 a 6 ciclos por hora Auto Discover ajuste autom tico Otras opciones 1 a 6 ciclos por hora Auto Discover ajuste autom tico Otras opciones 1 a 12 ciclos por hora Auto Discover ajuste autom tico Otras opciones 1 a 12 ciclos por hora Auto Discover ajuste autom tico Otras opciones 1 a 12 ciclos por hora Iluminaci n encendida por 45 seg despu s de oprimir tecla Iluminaci n siempre encendida en baja intensidad brillo total despu s de oprimir tecla Cambio Manual Opciones del usuario Heat Cool Off Cambio autom tico Opciones del usuario Heat Cool Auto Off El sistema selecciona heat cool basado en la temperatura de interior Temp Cal Ref con 3 F de diferencia 1 5 C Otras opciones 2 9 2 F a 9 F 1 C a 5 C Fahrenheit Celsius Cambio autom tico a horario de ahorro de energ a diurno 2007 y posterior para reas que usan el nuevo calendario 2007 DST Cambio autom tico a horario de ahorro de energ a diurno 2006 y para reas que no usan el n
32. scover arrangement automatique Arr t 90 jours de calendrier ou 30 jours de fonctionnement 180 jours de calendrier ou 60 jours de fonctionnement 365 jours de calendrier ou 90 jours de fonctionnement Auto Discover arrangement automatique Arr t 365 jours de calendrier 1 an 730 jours de calendrier 2 ans Marche Arr t 4 plages de programme Wake Leave Return Sleep 2 plages de programme Wake Sleep Arr t de 5 minutes du compresseur Autres choix 0 4 minutes Max Le r glage max de la temp rature de chauff 32 C 90 F Autres choix 4 C 32 C 40 90 F Min Le r glage inf rieur de la temp rature de clim 15 C 60 F Autres choix 15 C 37 C 60 a 99 F Heure sur 12 heures c d 3 30 pm Heure sur 24 heures c d 15 30 Arr t Autres choix Le ventilateur tourne pendant 30 60 90 120 sec ondes apr s la fin de l appel de chauffage Arr t Autres choix Le ventilateur tourne pendant 30 60 90 120 sec ondes apr s la fin de l appel de climatisation Clavier d verrouill compl tement fonctionnel Partiellement verrouill seulement commandes de temp rature Compl tement verrouill Temp rature de commande standard conseill e Choisissez si la pi ce est plus chaude que la temp rature r gl e Choisissez si la pi ce n atteint pas la temp rature r gl e Temp rature de commande standard conseill e Choisissez si l
33. tat contient une pile au lithium qui pourrait contenir du perchlorate Mat riau contenant du perchlorate des consignes de manipulation sp ciales pourraient s appliquer pri re de consulter www dtsc ca gov hazardouswaste perchlorate REMARQUE PROPOS DU MERCURE Si ce produit sert remplacer une com Installation Le thermostat s installe sur une bo te de jonction de 2 x 4 po sur un mur de placopl tre ou de pl tre l aide des chevilles d ancrage fournies percer des ouvertures de 3 16 po dans les murs de placopl tre percer des ouvertures de 7 32 po dans les murs de pl tre Raccorder les bornes 1 2 et 3 du thermostat aux bornes 1 2 et 3 du module d interface ou du tableau de zonage consulter le guide d installation du module d interface ou du tableau de zonage pour observer les sch mas de raccordement Placez date l heure Ann e Date oOo DO a CA Mois Appuyez DONE 20062 E af 1 00 en ROS En e U S Marque d pos e Brevets US N 6 208 263 6 373 376 6 448 901 Appuyez DONE pour quitter 6 595 430 7 012 927 7 044 397 D509151 et autres brevets en instance Copyright O 2008 Honeywell International Inc Tous droits r serv s Heure Installation Guide Configuration 1 Appuyer sur 2 Appuyez 5 secondes Appuyez DONE pour SYSTEM sauvegarder et quitter 3 Changez les arrangements voir p 10 14 E Ersten Ca Inside 4 am AUTO i DONE
34. te Debe instalarlo un t cnico capacitado y con experiencia Lea atentamente estas instrucciones Si las ignora podr a da arse el producto o generarse condiciones de peligro PRECAUCI N RIESGO EL CTRICO Puede ocasionar descargas el ctricas o da ar A el equipo Descon ctelo de la fuente de energ a antes de comenzar la instalaci n trol que contenga mercurio en tubo sellado evite arrojar el viejo control a la basura P ngase en contacto con la autoridad local para el manejo de desechos a fin de obten er instrucciones sobre el reciclado y la correcta eliminaci n de este tipo de desechos AVISO SOBRE EL MERCURIO En caso de que este producto reemplace a un con Este termostato tiene una bateria de litio que puede contener perclorato Perclorato puede ser necesario manipularlo con m todos especiales Visite www dtsc ca gov hazardouswaste perchlorate Instalaci n El termostato se puede montar en una caja J de 2 x 4 sobre tablarroca o sobre yeso usando anclas de expansi n en tablarroca realice agujeros de 3 16 y en yeso de 7 32 Conecte los terminales 1 2 y 3 del termostato a los terminales 1 2 y 3 del EIM o del Panel de Zona Consulte la Gu a de Instalaci n del EIM o del Panel de Zona para obtener informaci n acerca del cableado del termostato Fije fecha hora Fecha Que A o 4 Hora D Dm en A Marca registrada en EE UU Patente en EE UU N 6 208 263 6 373 376 6 448 901
35. thermostat controls heating fan Equipment controls stage 1 thermostat controls stage 2 Auto Discover 0190 Changeover valve O B terminal 0200 Backup heat Aux amp EmHeat O B terminal controls valve in cooling O B terminal controls valve in heating Auto Discover Electric backup heat Fossil fuel backup heat om 0 mN 0 See page 6 69 1816EFS 03 2 VisionPRO IAQ Installer setup Setup function Settings amp options factory default in bold 0210 0220 0230 0240 0250 0260 0280 0300 0310 0320 0330 0340 0342 0345 0346 0350 0360 0365 0370 External fossil fuel kit Stage 1 compressor 1cycle rate Stage 2 compressor cycle rate Stage 1 heat cycle rate CPH cycles per hour Stage 2 stage heat cycle rate CPH Stage 3 heat cycle rate CPH Backlight Manual Auto changeover Auto changeover deadband Temperature display Daylight savings Indoor temp sensor Outdoor temp sensor Dual fuel heat pump control Dual fuel heat pump upstage to furnace timer Heat pump compressor lockout Heat pump auxiliary lockout Discharge temp sensor Indoor humidity sensor O 0 0 N om NO O OO NO mo 10m External fossil fuel kit controls backup heat Thermostat controls backup heat outdoor sensor required Auto Discover Other options 1 to CPH Auto Discover Other options 1 to 6 CPH
36. tilaci n Funciones 0400 0406 Si hay equipo de la ventilaci n usted puede ventilar la casa a pedido funci n 0400 La casa puede ser ventilada autom ticamente si se detecta la humedad alta mientras que el sistema de calefacci n est encendido funci n 0406 69 1816EFS 03 22 VisionPRO IAQ Prueba del sistema Durante la configuraci n oprima y repetidamente hasta que aparezca N mero de prueba Estado d l sistema Test en pantalla 0120 4 ES ed 5 gt Looe __ LJ Oprima DONE para terminar la prueba la prueba E Oprima A y TELS para seleccionar 74 as Oprima A Y para cambiar el estado Prueba Estado del del sistema sistema Otros mensajes 1 Sistema de 0 Apagado P La ventilaci n se refrigeraci n 1 Prueba del sistema de refrigeraci n etapa 1 conforma con las 2 Prueba del sistema de refrigeraci n etapas 1 amp 2 regulaciones de ASHRAE 62 2 fun 2 Sistema de 0 Apagado ventilador 1 Encendido ci n 0404 3 Sistema de 0 Apagado F La ventilaci n no calefacci n 1 Prueba de la calefacci n etapa 1 se conforma con 2 Prueba de la calefacci n etapas 1 2 las regulaciones 3 Prueba de la calefacci n etapas 1 2 3 de ASHRAE 62 2 4 Prueba de la calefacci n etapas 1 2 3 4 funci n 0404 4 Sistema de 0 Apagado Err Vea los c digos calefacci n de 1 Prueba de la EmHeat etapa 1 de error emergencia 2 Prue
37. uevo calendario 2007 DST El horario de ahorro de energ a diurno est desactivado Temperatura de la medida solamente en el term stato Mida la temperatura en el location s de interior del sensor Temperatura media en el locations del term stato y del sensor es Auto Discover ajuste autom tico Ninguno Sensor alejado Punto del balance m s la inclinaci n 2 F Punto del balance solamente Punto del balance Aux Heat Cierre m s la inclinaci n 2 F 60 minutos Apagado Otras opciones 0 30 45 o 75 minutos Ninguno Otras opciones 5 a 60 F 15 C a 15 5 C Ninguno Otras opciones 5 a 65 F 15 C a 18 5 C Auto Discover ajuste autom tico No Si Vea la p gina 22 19 69 1816EFS 03 Installation Guide Funci n 0370 0372 0374 0379 0383 0384 0390 0391 0392 0393 0394 0400 0401 0402 0403 0404 0405 0406 Sensor interior de la humedad Control interior de 1 0 E E la humectaci n 0 1 3 0 Acci n del ventilador del humectador Control de la deshumidificaci n U x On Enfriar demasiado limite Ventilador de la deshumidificaci n la casa Casa vacante control 0 1 Modo vacante de o 1 0 del ventilador 1 Casa vacante tem 76 peratura l mite baja Casa vacante ajuste 85 de la temperatura Casa vacante ajuste 65 de la deshumidifi caci n Control de la o ventilaci n 1 2 N mer
38. uidor o con su representante de Honeywell para obtener una lista completa de productos compatibles Need Help For assistance with this product please visit http yourhome honeywell com or call Honeywell Customer Care toll free at 1 800 468 1502 Besoin d aide Pour obtenir de l aide et apprendre faire fonctionner votre produit Honeywell veuillez consulter le site Web http yourhome honeywell com ou vous adress er aux Services la client le de Honeywell en composant le 1 800 468 1502 Necesita ayuda Consulte sobre este producto en http yourhome honeywell com o llamando sin cargo a atenci n al cliente de Honeywell 1 800 468 1502 Automation and Control Solutions Honeywell International Inc Honeywell Limited Honeywell Limit e 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Toronto Ontario M1V 4Z9 http yourhome honeywell com Printed in U S A on recycled paper containing at least 10 O n eywe post consumer paper fibers U S Registered Trademark 2008 Honeywell International Inc 69 1816EFS 03 M S Rev 06 08
39. umidificateur actionne le ind pendant du ventilateur Aucune commande de d shumidification Employez le climatiseur pour commander l humidit D shumidificateur entier de maison 1 5 C 3 F Autres choix 1 2 0 5 C ou 1 5 C 1 F ou 2 F Le ventilateur de syst me s allume avec le d shumidificateur Le d shumidificateur actionne le ind pendant du ventilateur Non Oui Ventilateur auto Ventilateur toujours dessus Circulation d air Basse temp rature limite 24 C 76 F Autres choix 21 C 27 C 70 F 80 F Maison vide temp rature 29 C 85 F Autres choix 21 C 27 C 70 F 99 F Maison vide niveau d humidit 65 Autres choix 55 70 Aucune ventilation La ventilation a toujours laiss Ventilation non permise pendant la p riode du Sleep Deux chambres coucher Autres choix 1 6 1 000 pieds carr s Autres choix 11 50 1 100 5 000 pieds carr s CFM pieds cubes par minute Autres choix 30 195 CFM 50 limite de ventilation Autres choix 30 60 ou 100 Se conforme aux r glements d ASHRAE 62 2 Ne se conforme pas aux r glements d ASHRAE 62 2 La ventilation force le ventilateur dessus La ventilation ne force pas le ventilateur dessus Marche mode de la chaleur seulement Arr t Voir la page 14 12 VisionPRO IAQ Configuration Fonctions Param tres et choix d faut usine en gras 0500 0502
40. urante per odo del Sleep Dos dormitorios Otras opciones 1 a 6 1 000 pies cuadrados Otras opciones 11 a 50 1 100 a 5 000 pies cuadrados Pies c bicos por minuto Otras opciones 30 a 195 CFM 50 limite de ventilation Otras opciones 30 a 60 o 100 Se conforma con la regulaci n de ASHRAE 62 2 No se conforma con la regulaci n de ASHRAE 62 2 La ventilaci n fuerza el ventilador encendido La ventilaci n no fuerza el ventilador encendido S modo del calor solamente Apagado Vea la p gina 22 20 VisionPRO IAQ Funci n Ajustes y opciones configuraci n de f brica en negritas 0500 Recordatorio de cambio del filtro de la estufa oOnhon OoOMm 0502 Opciones del filtro de la estufa 0510 Recordatorio de cambio del pa o del humidificador 0520 Recordatorio de cambio de lampara UV 0530 Adaptive Intelligent Recovery 0540 Periodos del programa a NA OA NOM NOM 0 0580 Compresor tiempo apagado 0600 Tope de rango de temp de calefacci n 0610 Tope de rango de 60 temp de refrigeraci n 0640 Formato de reloj 12 24 0650 Temporizador de 0 ventilador extendido calefacci n 0660 Temporizador de 0 ventilador extendido refrigeraci n 0670 Bloqueo del teclado o 0680 Control de temp de calefacci n o 1 2 2 1 3 0690 Control de temp 2 de refrigeraci n 1 3 0700 Compensaci n de 0 la pantalla de temp 0701 Compensaci n de la O
41. uration d installation Num ro du test Etat de l installation appuyez plusieurs fois sur W jusqu ce que Test apparaisse r ge DONE TES Appuyez Y pour s lectionner un test pone f Appuyez Y pour modifier l tat Appuyez DONE pour terminer les essais Essai de Etat de installation l installation D autres messages 1 Installation de climatisation Arr t P La ventilation est conforme Essai de refroidissement tape 1 aux r glements d ASHRAE Essai de refroidissement tapes 1 2 62 2 fonction 0404 Arr t Marche F La ventilation n est pas Arr t conforme aux r glements Essai de chauffage tape 1 d ASHRAE 62 2 fonction Essai de chauffage tapes 1 2 0404 Essai de chauffage tapes 1 2 3 0 1 2 2 Ventilateur 0 1 0 1 2 3 A i 4 Essai de chauffage tapes 1 2 3 4 Err Voir les codes d erreur 0 1 2 0 1 0 1 0 1 3 Installation de chauffage Arr t Essai de EmHeat tape 1 Essai de EmHeat tapes 1 2 Arr t RS 1 MISE EN GARDE RISQUE 4 Installation de chauffage d urgence 5 Humidificateur D ENDOMMAGER L QUIPEMENT La pro tection du compresseur temps d arr t minimum est contourn e pendant les essais Pour ne pas Arr t endommager le mat riel vitez d arr ter et de Marche mettre en marche en succession rapide Arr t Marche 6 D shumidificateur 7 Ventilateur Comment proc der au test du

Download Pdf Manuals

image

Related Search

Related Contents

Vampir 8 User Manual  MirrorOp Presenter User's Manual  Mise en page 1 - CFE-CGC  マイコムテレビパッケージの接続方法について  Mode d`emploi des taxes foncières 2012  安全データシート - Santa Cruz Biotechnology  Rotel RX-1052 Stereo System User Manual  取扱説明書 HPー4372  Danfoss TLX User Manual ML L00410310  177728 - termometro interno esterno radio, a colori, radiocontrollato  