Home
Honeywell F115 User's Manual
Contents
1. Sound Level at 3 3 ft 1m F114 59 dBA on High speed 55 dBA on Low speed F115 52 to 56 dBA Replacement Parts and Accessories See Parts List on page 8 PLANNING THE INSTALLATION A WARNING Electrical Shock Hazard Power source can cause personal injury Do not damage electrical wiring or hidden utilities when cutting or drilling into the wall or ceiling Do not install where the media air cleaner can be reached from a tub or shower e Always turn off the power at the service panel Lock the panel to prevent the power from being switched on accidentally when servicing or cleaning the media air cleaner Choose Location The air cleaner is mounted horizontally and can be used in almost any air cleaning application For the most efficient operation centrally locate the air cleaner to the area to be cleaned For the best air patterns avoid discharging the air directly at an obstruction such as a ceiling beam decorative cornice or pillar The discharge air pattern has a range of 20 to 25 ft 6 to 7 5m at full speed IMPORTANT Do not install at heights greater than 16 ft 4 8m When multiple air cleaners are needed for a large area divide the space into equal areas and centrally mount the air cleaners See Fig 3 68 0201 2 Revised 11 07 F114 AND F115 CEILING SURFACE MOUNTED MEDIA AIR CLEANERS MEDIA AIR CLEANER t A D gt 4 AIR SPACE TO BE CLEANED piscHarce AIR FLOW IN ANY DIRE
2. ACE MOUNTED MEDIA AIR CLEANERS 1 Grasp the edge of the air cleaner cover near the CAUTION plenum and remove the cover from the support Electrical Shock Hazard brackets lta eg P hock 2 Remove the prefilters e ia can a ah ad Ben clean 3 Check the prefilters and replace them if they are fully urn off the power to the air cleaner when cleaning coated with dust and lint approximately every 1 to 3 or servicing l months Standion a stable platiorm When Working 4 Replace the CPZ cartridge when a continuous with the air cleaner noticeable odor is emitted from the air cleaner approximately every 4 to 12 months uN CAUTION 5 Replace the primary filter when there is a noticeable loss of air volume circulation approximately every 10 Eye Exposure to 24 months elle dust can obstruct or injure unshielded 6 Reassemble the air cleaner and turn the power on A CPZ module usually releases dust when it is handled Always wear safety glasses when installing or removing CPZ canisters PARTS LIST Refer to Table 2 or 3 and Fig 6 or 7 for a parts list and an exploded view of the parts Table 2 F114 Ceiling Surface Mounted Media Air Cleaner Parts List Fig oo Pack Qty Order Number Reference No oz sosoteneer f HEPA filter requires 2 21500 D O P Particle filter requires 2 28710 OoOo 8 Disposable CPZ cartridge requires 2 36210 e 68 0201 2 Revised 11 07 6 F114 AND F115 CEILING SURFAC
3. CTION IS ACCEPTABLE M11694 Fig 3 Choose location for air cleaners IMPORTANT uN CAU TI O N When selecting a location make sure the air cleaner is secured to ceiling load bearing supports Electrical Shock Hazard or joists If installing on a T grid drop ceiling secure Power source can shock the air cleaner to the true ceiling e Do not connect the power source until after the air cleaner is mounted This will prevent electrical INSTAL LATION shock or equipment damage e Be sure to turn off the air cleaner before servicing it When Installing this Product e If the air cleaner must be turned on for an electrical check be extremely cautious Be cautious when working near the moving parts 1 Read these instructions carefully Failure to follow of the air cleaner them could damage the product or cause a hazardous condition 2 Check the ratings given in the instructions and on the Mount and Wire the Air Cleaner product to make sure the product is suitable for your lication uN 3 Aen be a trained experienced service CAUTION technician Eye Exposure 4 After installation is complete check out product Harmful dust can obstruct or injure unshielded operation as provided in these instructions eyes A CPZ module usually releases dust when it is handled Always wear safety glasses when installing or removing CPZ canisters 68 0201 2 Revised 11 07 4 F114 AND F115 CEILING SURFACE MOUNTED MEDIA AI
4. E MOUNTED MEDIA AIR CLEANERS Xo M12711 Fig 6 Exploded view of F114 Ceiling Surface Mounted Media Air Cleaner components 68 0201 2 Revised 11 07 F114 AND F115 CEILING SURFACE MOUNTED MEDIA AIR CLEANERS Table 3 F115 Ceiling Surface Mounted Media Air Cleaner Parts List Fig Reference No Reference No Prefilter 1 box 36015 HEPA filter requires 4 21500 D O P Particle filter requires 4 28710 Disposable CPZ canister requires 4 36210 68 0201 2 Revised 11 07 8 F114 AND F115 CEILING SURFACE MOUNTED MEDIA AIR CLEANERS INSPECTION ACCESS PLATE SY N SS Wy Y H Zz E ES TY Lip LAA x N Y O N Fig 7 Exploded view of F115 Ceiling Surface Mounted Media Air Cleaner components 68 0201 2 Revised 11 07 F114 AND F115 CEILING SURFACE MOUNTED MEDIA AIR CLEANERS LIMITED TWO YEAR WARRANTY Air Pure Systems warrants its air cleaner products to be free from defects in workmanship or materials under normal use and service for a period of two 2 years from the date of purchase by the originial end user If at anytime during the warranty period the product is defective or malfunctions Air Pure Systems through the distributor or dealer from which the product was purchased or through an authorized warranty repair station shall at Air Pure Systems option replace or repair the defective product or component This warranty does not
5. Honeywell F114 and F115 Ceiling Surface Mounted Media Air Cleaners GENERAL The F114 and F115 Ceiling Surface Mounted Media Air Cleaners use direct drive forward curve blower motors with 95 D O P particle or HEPA filters to remove airborne contaminants The air cleaners are designed for use in restaurants conference rooms lounges and offices where overhead air cleaning is required They provide their own air circulation so the air cleaners can be used in any situation that requires the reduction of contamination from an enclosed area The Honeywell Trademark is used under license from Honeywell Intellectual Properties Inc by Air Pure Systems Honeywell International Inc makes no representations or warranties with respect to this product PRODUCT DATA FEATURES High Efficiency Particulate AIR HEPA filter models are 99 97 efficient and the D O P particle filter models are 95 efficient at 0 3 micron particles Both models are more efficient on particles smaller and larger e F114 two speed direct drive forward curve motor blower models deliver up to 325 cfm 550 m3 hr e F115 single speed models deliver up to 600 cfm 1020 m3 hr e Select models include CPZ disposable canisters for odor control Light colored covers complement the ceiling finish e Available in 120 Vac 60 Hz or 220 240 Vac 50 60 Hz models READ AND SAVE THESE INSTRUCTIONS Contents GONG Kall EE AEAEE E iste wists e
6. R CLEANERS IMPORTANT When installing the air cleaner be sure to follow all local codes and accepted practices 1 Decide if the air cleaner wire connections will be from from the top or the side Make the necessary wiring provisions at the ceiling 2 Grasp the air cleaner cover edge near the plenum and remove the cover from the support brackets Set it aside 3 Loosen and remove the filter securing nuts holding plates and filters Set them aside 4 Insert fastening hardware lag bolts eye bolts or threaded rod through the 3 8 in 10 mm mounting holes in the filter motor bases See Fig 1 or 2 5 Secure the air cleaner to the ceiling load bearing supports or joists If installing on a T grid drop ceiling secure the air cleaner to the true ceiling 6 Fasten the plenum assembly snugly against the ceiling IMPORTANT Do not over tighten the plenum fasteners which can collapse or break the plastic base plenum 7 Connect the power See Fig 4 and 5 JUNCTION BOX Se Kr CONDUIT IN PLENUM M11693 Fig 4 F114 Media Air Cleaner 120 60 Hz typical wiring diagram l CONDUIT IN PLENUM Pa M12736 Fig 5 F115 Media Air Cleaner 120 60 Hz typical wiring diagram IMPORTANT Make sure the air cleaner is grounded for proper operation and safety 8 Turn on the power and check that the blowers are operating freely 9 Position the filter cartridges on the filter base 10 Insert the CPZ cartridg
7. Vac 60 Hz 1PHS 3 6A 95 7 220 240 Vac 50 60 Hz 1PHS 1 7A 95 7 F115 120 Vac 60 Hz 1PHS 7 2A 99 97 HEPA N A 220 240 Vac 60 Hz 1PHS 8 6A 99 97 HEPA N A F115C 120 Vac 60 Hz 1PHS 7 2A 95 12 220 240 Vac 50 60 Hz 1PHS 3 6A 95 12 aNot applicable ORDERING INFORMATION If you have additional questions need further information or would like to comment on our products or services please write or phone 1 Your local Honeywell Commercial Air Products Distributor 2 Air Pure Systems 16873 Fish Point Rd SE Prior Lake MN 55372 1714 Phone 800 998 1919 Fax 800 221 3248 www cleanairfacility com 68 0201 2 Revised 11 07 2 F114 AND F115 CEILING SURFACE MOUNTED MEDIA AIR CLEANERS Dimensions See Fig 1 and 2 for dimensions 7 1 2 952 a 34 1 8 867 l 8 7 8 733 moy 1 1 4 31 lt 3 8 IN 10 DIAMETER MOUNTING HOLES 2 POWER INPUT POINT M12735 Fig 1 Approximate dimensions of F114 in in mm POWER INPUT POINT m 3 8 IN MOUNTING HOLES 4 34 3 4 859 406 28 7 8 724 yan POWER INPUT POINT au 6 A 9 3 4 248 M11688 lt _ _ 34 3 4 859 Fig 2 Approximate dimensions of F115 in in mm Installation Weight F114 approximately 40 lbs 18 kg F115 approximately 80 Ibs 36 kg Controls F114 two speed On Off switch F115 direct wired optional remote mounted On Off switch
8. cover removal or installation costs This warranty shall not apply if it is shown that the defect or malfunction was caused by damage which occurred during handling or shipment improper electrical connections improper use of the product or abuse Air Pure Systems sole responsibility shall be to repair or replace the product within the terms stated above AIR PURE SYSTEMS SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow the exclusion or limitation or incidental or consequential damages so this limitation may not apply to you THE WARRANTIES SET FORTH HEREIN ARE EXCLUSIVE AND AIR PURE SYSTEMS EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES WHETHER WRITTEN OR ORAL IMPLIED OR STATUTORY INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OR MERCHANTABILITY WORKMANSHIP OR FITNESS FOR A PARTICULAR USE This warranty gives you specific legal rights and you may have other rights which vary from state to state How to make a warranty claim or have questions answered Should you have a warranty claim or questions about the warranty policy contact the distributor or dealer from which you purchased the product or the authorized warranty repair stations nearest your location NOTE Do not return any products or parts to the factory without a factory issued Return Wa
9. e Ls OR EA 1 Features ccs2scsss dates cate ctcskenssdstiieese cuassseedhiees tes aeeensete seagrass 1 SPOCIICATIONS sorsien eane er iiien Eaa Saia 2 Ordering Information oeseri 2 Planning the Installation 0 0 eee eeeseeeeeeeeeeeeeeeeneeeeeees 3 Installation iosian iea a a 4 OPO KAU OM ars cos iieiea eie eesin a ide a oE Eh EENE eat 5 MOST VIG e E E E A E A N 5 Pars List setts e eee eee 6 Warranty ernennen i araa a 10 68 0201 2 Revised 11 07 F114 AND F115 CEILING SURFACE MOUNTED MEDIA AIR CLEANERS SPECIFICATIONS eee Refer to Table 1 for model descriptions IMPORTANT Color The specifications given in this publication do not F114 white cabinet and cover include normal manufacturing tolerances Therefore F115 white cabinet and cover this unit may not exactly match the listed specifications This product is tested and calibrated Blower Motor under closely controlled conditions and some minor F114 two speed direct drive forward curve differences in performance can be expected if those F115 single speed direct drive forward curve conditions are changed Table 1 F114 and F115 Description HI 325 550 LOW 180 306 HI 350 595 LOW 200 340 fon 2 T Q DS 2 Efficiency Particulates at 0 3 Approximate CPZ Model Voltage Micron D O P Test components in pounds F114A 120 Vac 60 Hz 1PHS 3 6A 99 97 HEPA N A 220 240 Vac 60 Hz 1PHS 1 7A 99 97 HEPA NA F114C 120
10. e with the cartridge base notches against the motor towers 11 Attach the filter cover plates 12 Replace the air cleaner cover OPERATION The F114 and F115 Ceiling Surface Mounted Media Air Cleaners provide their own air circulation When the air cleaner is powered the blower motor draws the contaminated air into the air cleaner Particles that are too small to be caught in the prefilter are removed by the particle or HEPA filter The cleaned air is then returned to the building space In areas with ceilings up to 10 feet high the F114 models can effectively clean an area of 200 to 600 sq ft 18 to 54 sq m The F115 models can clean a 600 to 1200 sq ft 54 to 108 sq m area SERVICE The air cleaner removes a variety of particulate contaminants from the air In the process of cleaning the air the air cleaner filters become dirty To maintain a high standard of reliability and efficiency it is necessary to periodically service the air cleaner The filter life is determined by the quantity and type of contaminants present and the frequency of air cleaner use In relatively clean spaces the filter life can extend as long as 30 months In areas that are very smoky and dusty filters need to be replaced sooner The frequency of servicing can only be established after a period of use NOTE Some Full Service Distributors provide regular servicing to commercial establishments 68 0201 2 Revised 11 07 F114 AND F115 CEILING SURF
11. rranty Good Label issued by Air Pure Systems In the event you or other persons have any questions concerning the use and care of this product of this warranty please call or write the factory Air Pure Systems 16873 Fish Point Rd SE Prior Lake MN 55372 1714 Phone 800 998 1919 Fax 800 221 3248 Air Pure Systems 16873 Fish Point Rd SE Prior Lake MN 55372 1714 Phone 800 998 1919 Fax 800 221 3248 68 0201 2 Revised 11 07 10 www cleanairfacility com