Home

Heath Zenith SL-5408 User's Manual

image

Contents

1. ON TIME SENS a 10 5 1 TEST Z gt gt Bottom of Sensor Avoid aiming the control at Objects that change temperature rapidly such as heating vents and air conditioners These heat sources could cause false triggering Areas where pets or traffic may trigger the control Nearby large light colored objects reflecting light may trigger the shut off feature Do not point other lights at the sensor e e 110 un 60 ft 18 3 m Maximum Range Maximum Coverage Angle The detector is most sensitive to motion across its field of view O Least Sensitive Most Sensitive 595 5292 18 O Loosen the clamp screw in the sensor ball joint and gen he tly rotate the sensor O Walk through the coverage area noting where you are when the lights turn on Move the sensor head up down or sideways to change the cov erage area Keep the sensor at least 1 2 5 cm away Aim Sensor from the lamps es for Short O Adjust the SENSITIVITY as overage needed Too much sensitivity may increase false triggering O Secure the sensor head by Aim Sensor tightening the clamp screw Higher for Long Do not overtighten the screw Coverage O Set the amount of TIME you want the lights to stay on after motion is detected 1 5 or 10 minutes Warning Risk of fire Do not aim the lamps at a combustible surface within 3 ft 1 m SPECIFICATIONS
2. de joint A Commande d clairage 2 serre fils Exigences La commande d clairage n cessite une alimenta tion de 120 V c a Pour utiliser la priorit manuelle raccorder la commande un interrupteur Certains codes de b timent locaux peuvent exiger que l installation soit faite par un lectricien qualifi Ce produit est con u pour tre utilis avec une bo te de jonction portant une indication d utilisation pos sible en milieu humide Pour votre commodit la plaque arri re est maintenant pourvue de trous d bouchures pour que l appareil puisse facilement tre mont sur presque n importe quelle bo te de jonction Pour certaines applications une plaque d adaptation universelle peut tre n cessaire On peut se procurer ces plaques d adaptation dans des centres de r novation domiciliaire et magasins de fournitures lectriques 2004 DESA Specialty Products FONCTIONNEMENT Mode Temps en circuit En fonction Jour Nuit Essal 5 secondes x x Auto 1 5 ou 10 min x Manuel au choix x amanecer Revient au mode automatique au lever du soleil Note Apr s mise en circuit attendre enfiron 1 1 2 minute pour que l talonnage du circuit soit compl t ESSAI Amener en position d essai TEST ON TIME l interrupteur de temps en circuit ON TIME du bas du d tecteur 105 1 TEST AUTOMATIQUE Amener
3. Put the ON TIME switch onthe bottom ON TIME of the sensor in the TEST position 105 1 TEST AUTO Putthe ON TIME switch inthe 1 5 or ON TIME 10 minute position 1051 TEST MANUAL MODE Manual mode only works at night because daylight returns the sensor to AUTO Flip the light switch offforonesecond 4 Second OFF then back on to toggle between AUTO then and MANUAL MODE Manual mode works only with the ON SA TIME switch in the 1 5 or 10 position back on Mode Switching Summary Move ON TIME Switch to 1 5 or 10 minutes Flip light switch off for one second then back on MANUAL MODE If you get confused while switching modes turn the power off for one minute then back on After the calibration time the control will be in the AUTO mode 595 5292 18 INSTALLATION For easy installation select an existing light operated by a wall switch for replacement For best performance mount the fixture about 8 feet 2 4 m above the ground O Drillthe holes needed to mount the backplate to the junction box Wall Mount Eave Mount For under eave installation the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock For eave mount only O Rotate the sensor head towards the clamp screw joint Control Switch os E Joint Clamp O Then rotate the senso
4. RE ET SPECIFIQUEMENT DE TOUS DOMMAGES SPECIAUX DIRECTS INDIRECTS OU SECONDAIRES LE REMPLACEMENT OU LA REPARATION CONSTITUENT LE SEUL RECOURS DU CLIENT ET DESA SPECIALTY PRODUCTS NE POURRA ETRE TENUE RESPONSABLE DE TOUS DOMMAGES SPECIAUX DIRECTS INDIRECTS OU SECONDAIRES Y COMPRIS SANS S Y LIMITER LES PERTES COMMERCIALES ET PERTES DE PROFIT QU ELLES SOIENT PREVISIBLES OU NON Certaines provinces n autorisent pas l exclusion ou la limitation des dommages indirects ou secondaires et la limitation ou l exclusion ci dessus pourrait ne pas s appliquer vous Pour toute r clamation en vertu de la garantie il est n cessaire de pr senter une preuve d achat 12 595 5292 18
5. l interrupteur de temps en ON TIME circuit ON TIME a la position correspondant a 1 5 ou 10 minutes 1051 TEST PRIORIT MANUELLE Le mode manuel ne fonctionne que la nuit parce que la lumi re du jour remet le capteur en mode AUTO Mettre l interrupteur hors circuit pen dant une seconde plus en circuit 1 Second OFF pour alterner entre les modes AUTO tien et MANUEL Le mode manuel ne fonctionne SA qu avec l interrupteur ON TIME aux positions 1 5 ou 10 Back on PRIORITE MANUELLE Si vous ne savez plus dans quel mode se trouve l appareil R sum du mode de commutation Placer l interrupteur ON TIME 1 5 ou 10 minutes Mettre l interrupteur hors circuit pendant une seconde puis le remettre en circuit couper l alimentation pendant une minute puis la r tablir Apr s le temps d talonnage la commande reviendra au mode AUTO 595 5292 18 F INSTALLATION Pourfaciliter l installation choisir un appareil d clairage devant tre remplac et qui est d j command par un interrupteur Pour assurer un rendement maximal monter l appareil d clairage environ 2 4 m tres au dessus du sol O Percezlestrousn cessaires au montage de la plaque arri re a la bo te de K jonction lt S Montage sous avant toit Montage mural Pour viter le risque de choc lectrique les commandes du d tecteur doivent tre
6. se llama al Servicio T cnico por favor tener lista la siguiente informaci n N mero de Modelo Fecha de compra y Lugar de compra No hay piezas de servicio disponibles para este producto GARANT A LIMITADA A 2 A OS Esta es una Garant a Limitada que le da a Ud derechos legales espec ficos Usted puede tambi n tener otros derechos que var an de estado a estado o de provincia a provincia Por un per odo de 2 a os desde la fecha de compra cualquier mal funcionamiento ocasionado por partes defectuosas de f brica o mano de obra ser corregido sin cargo para Ud No cubierto Servicio de reparaci n ajuste y calibraci n debido al mal uso abuso o negligencia bombillas bater as u otras partes fungibles no est n cubiertas por esta garant a Los Servicios no autorizados o modificaciones del producto o de cualquier componente que se provee invalidar n esta garant a en su totalidad Esta garant a no incluye reembolso por inconveniencia instalaci n tiempo de instalaci n perdida de uso servicio no autorizado o costos de transporte de retorno Esta garant a cubre solamente los productos ensamblados por DESA Specialty Products y no se extiende a otros equipos o componentes que el consumidor usa junto con nuestros productos ESTA GARANT A EST EXPRESAMENTE EN LUGAR DE OTRAS GARANT AS EXPRESADAS O SOBREENTENDIDAS INCLUYENDO CUALQUIER GARANT A REPRESENTACI N O CONDICI N DE COMERCIABILIDAD O QUE LOS PRODUCTOS SE ADAPTEN
7. sito de autom viles Reapunte el detector La Sensibilidad es demasiado alta Reduzca la sensibilidad La luz se queda prendida continuamente La luz se prende y se apaga 1 Unfaro est colocado demasiado cerca aldetectoro apunta a objetos cercanos que hace que el calor active el detector Reposicione la l mpara lejos del de tector o de los objetos cercanos El Control de Luz est apuntando hacia una fuente de calor tal como un conducto de aire de secadora o hacia una superficie con pintura brillante y que refleja el calor Reposicione el detector El control de luz est en la Modo Manual C mbiela a Autom tica El calor o la luz de las l mparas pueden estar prendiendo y apagando el Control de Luz Reposicione las l mparas lejos del detector Elcalor que se refleja de otros objetos puede estar afectando al detector Reposicione el detector El Control de Luz est en fase de Prueba y calent ndose El prenderse y apagarse es normal bajo estas condiciones Laluz puede estarescap ndose porlos reflectores del faro Cambie los faros con nuevas l mparas de alta calidad SERVICIO T CNICO No enviar los productos Si tiene alg n problema por favor siga esta gu a Lo sentimos pero no podemos contestar preguntas en espa ol por tel fono Usted puede tambi n escribir a DESA Specialty Products P O Box 90004 Bowling Green KY 42102 9004 Si
8. Heath Zemth Motion Sensor Light Control As an ENERGY STAR Partner Heath Zenith has determined that this product meets the ENERGY STAR guidelines for energy effi ciency This product is ENERGY STAR com pliant when used with 120 Watt bulbs Model SL 5408 Features e Turns on lighting when motion is detected e Automatically turns lighting off Photocell keeps the lighting off during daylight hours This package includes ua 4 Mounting Screws 2 sizes Cover Lamp Holders Plate Sensor Gasket NG 2 Wire Connectors SS Light Control Requirements The Light Control requires 120 volts AC If you want to use Manual Mode the control must be wired through a switch Some codes require installation by a qualified electrician This product is intended for use with a junction box marked for use in wet locations The backplate has knockouts so the sensor can be mounted on most junction boxes Insome applications a universal adaptor plate may be needed Adaptors are available at home centers and electrical supply stores 2004 DESA Specialty Products OPERATION Mode On Time Works Day Night Test 5 Sec x x Auto 1 5 10 min x Manual Until Dawn X resets to Auto Mode at dawn Note When first turned on wait about 1 2 minutes for the circuitry to calibrate TEST
9. LIMITED TO ANY LOSS OF BUSINESS OR PROFITS WHETHER OR NOT FORESEEABLE Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Proof of purchase is required for warranty claims 4 595 5292 18 Heath Zemth Detector de Movimiento y Control de Luz Como socio de ENERGY STAR Heath Ze nith ha determinado que este producto cumple con las pautas de ENERGY STAR con respecto a eficiencia de energia Este producto esta en conformidad con ENERGY STAR cuando se usa con focos de 120 vatios Modelo SL 5408 Caracter sticas e Prende la luz cuando detecta movimiento e Apaga la luz autom ticamente e La fotoc lula mantiene la luz apagada durante el d a a ENERGY STAR Este paquete tiene Placa Cubertora Porta l mparas 4 Tornillos Vs T 2 dimensiones NI LA LL CA N E Detector 2 Tuercas para Alambre Control de Luz Empaquetadura Requisitos El Control de Luz requiere 120 VCA Para usar el Sobrecontrol Manual conecte el control con un interruptor Algunos c digos requieren instalaci n por un electricista calificado Este producto debe ser usado con una caja de empalmes marcada para ser usada en lugares mojados La placa trasera tiene discos removibles para poder montar el detector en casi todas las cajas de empalmes En algunas aplicaciones se p
10. PARA CUALQUIER PROP SITO O USO EN PARTICULAR Y ESPECIFICAMENTE EN LUGAR DE TODOS LOS DA OS ESPECIALES INDIRECTOS INCIDENTALES Y CONSECUENTES LA REPARACI N O EL REEMPLAZO DEBER A SER LA NICA SOLUCI N DEL CLIENTE Y NO HABR RESPONSABILIDAD POR PARTE DE DESA SPECIALTY PRODUCTS POR CUALQUIER DA O ESPECIAL INDIRECTO INCIDENTAL O CONSECUENTE INCLUIDOS PERO NO LIMITADOS A CUALQUIER P RDIDA DE NEGOCIO O GANACIAS SEAN O NO PREVISIBLES Algunos estados o provincias no permiten la exclusi n o limitaci n de da os incidentales o consecuentes de modo que la limitaci n o exclusi n arriba indicada puede que no se aplique a Ud Para reclamos por la garant a se requiere la prueba de compra 8 595 5292 18 Heath Zemth Commande d clairage d tecteur de mouvement ENERGY STAR En tant que partenaire ENERGY STAR Heath Zenith a d termin que ce produit satisfait aux directives d efficacit nerg tique ENERGY STAR Ce produit est conforme ENERGY STAR lorsqu il est utilis avec des ampoules de 120 watts Mod le SL 5408 Caract ristiques e Allume l clairage lorsqu un mouvement est d tect e Eteint automatiquement l clairage e Photocellule qui maintient l clairage teint pendant la p riode de lumi re du jour Cet emballage comprend Douilles de lampe a 4 vis incluses 2 formats Plaque de garde D tecteur DN Garniture A
11. RRANTY This is a Limited Warranty which gives you specific legal rights You may also have other rights which vary from state to state or province to province For a period of two years from the date of purchase any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you Not Covered Repair service adjustment and calibration due to misuse abuse or negligence light bulbs batteries and other expendable items are not covered by this warranty Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety This warranty does not include reimbursement for inconvenience installation setup time loss of use unauthorized service or return shipping charges This warranty covers only DESA Specialty Products assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY WARRANTY REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE AND SPECIFICALLY IN LIEU OF ALL SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF DESA SPECIALTY PRODUCTS FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT
12. Range Up to 60 ft 18 3 m varies with surrounding temperature Sensing Angle Up to 110 Electrical Load Up to 300 Watt Maximum In candescent Up to 150 Watt maximum each lamp holder 120 VAC 60 Hz TEST AUTO and MANUAL MODE Time Delay 1 5 10 minutes Range Adjustable Power Requirements Operating Modes DESA Specialty Products reserves the right to dis continue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold SYMPTOM TROUBLESHOOTING GUIDE POSSIBLE CAUSE POSSIBLE CAUSE SYMPTOM Lights will not come on Lights come on in daylight Lights come on for no apparent rea son Light Control is Light switch is turned off Flood light is loose or burned out Fuseis blown or circuit breaker is turned off Daylight turn off is in effect re check after dark Incorrect circuit wiring if this is a new installation Re aim the sensor to cover de sired area Light Control may be installed in a relatively dark location in Test Set control switch to an ON TIME position Light Control may be sensing small animals or automobile traf fic re aim sensor Sensitivity is set too high Re duce sensitivity Lights stay on continuously Lights flash on and off 1 A flood lamp is positi
13. e l horizontale KR Ajusterles douilles de fa on que les lampes se trouvent au moins 25 mm du d tecteur O Ajuster les porte lampes en desserrant les crous de blocage mais ne pas faire tourner les porte lampes de plus de 180 par rapport au r glage d usine Ne pas trop serrer les lampes dans les porte lampes 595 5292 18 ESSAIS ET REGLAGES O Mettre en circuit le disjoncteur et l interrupteur d clairage Tourner la commande de sensibilit SENS la position interm diaire et la commande de temps en circuit ON TIME TEST NOTE Le capteur doit se r chauffer 1 2 minute avant de pouvoir d tecter le mouvement Lorsque l appareil est mis en circuit attendre 1 1 2 minute ON TIME SENS oe D I SS MIN MAX 10 51 TEST Bas du d tecteur viter de pointer l appareil en direction d objets dont la temp rature change rapidement tels que des bouches d air chaud et des climatiseurs De telles sources de chaleur peuvent provoquer des d clenchements intempestifs vers des endroits o des animaux des v hicules ou des passants peuvent d clencher la commande sur de grands objets clairs proximit qui r fl chissent la lumi re du jour et risquent de d clencher le dispositif d arr t Ne pas pointer d autres appareils d clairage vers le d tecteur 10 2 4m 18 3 m Port e maxima
14. entation lectrique Modes de fonctionnement Essai automatique etpriorit manuelle D lais 1 5et 10 minutes Port e R glable DESA Specialty Products se r serve le doit d abandonner tout produit et d en changer les sp cifications en tout temps et sans contracter quelque obligation que ce soit quant l incorporation de nouvelles caract ristiques aux produits d ja vendus SYMPTOME GUIDE DE DEPANNAGE CAUSE POSSIBLE CAUSE POSSIBLE SYMPTOME L clairage s allume pas ne L clairage s allume en plein jour L clairage s allume sans raison apparente L interrupteur d clairage est hors tension Le projecteur est d viss ou br l Lefusible a saut oule disjoncteur a t d clench Le dispositif de coupure pendant le jour fonctionne V rifiez nouveau la noirceur Mauvais c blage du circuit dans le cas d une nouvelle installation R orientez le capteur pour couvrir la zone d sir e Lacommande peut tre install e dans un endroit relativement sombre La commande est en mode TEST Placez l interrupteur de la commande a une postion ON TIME La commande peut d tecter de petits animaux ou la circulation au tomobile R orientez le d tecteur Le r glage de port e est trop L clairage reste 1 allum continuellement L clairage clignote Un projecteur e
15. le Angle de couverture maximale Le d tecteur est moins sensible au mouvement dans sa direction Mouvement Mouvement D tecteur Le moins sensible Le plus sensible 595 5292 18 O Desserrer la vis de blocage de la rotule et faire pivoter le d tecteur pour pointer Vis de f blocage O Marcher dans la zone de couverture et noter quel endroit l clairage se d clenche D placer la t te du d tecteur vers le haut le bas ou le c t pour modifier la Rotule zone de couverture Ne pas Pointer le permettre au d tecteur d tecteur vers d tre moins de 25 mm le bas pour des lampes r duire la O R gler la sensibilit sens oUverture TIVITY selonles besoins Une trop grande sensibilit pourrait causer des d clenchements i intempestifs Pointer le d tecteur vers O Fixer la t te du d tecteur en le haut pour position en serrant la vis de augmenter la blocage Eviter de trop serrer couverture la vis O Placer l interrupteur ON TIME 1 5 ou 10 minutes Avertissement Risque d incendie Ne pas pointer les lampes vers une surface combustible situ e a moins de 1 m tre FICHE TECHNIQUE Jusqu a 18 3 m 60 pi Varie selon la temp rature ambiante Jusqu a 110 Jusqu a deux ampoules incandescentes pour un maximum de 300 W maxi mum de 150 W par support 120 V CA 60 Hz Angle de d tection Charge lectrique Alim
16. nillos de montaje O Calafatee la placa de la pared y la superficie de montaje con un sellador de silicona contra la intemperie Evite el golpe el ctrico y el da ado causado por el agua mantengalos portal mparas abajo del nivel horizontal SS 7 Mantenga las l mparas por lo menos a 25 mm del detector Contratuercas O Ajustelos portal mparas aflojando las contratuercas pero no los gire m s de 180 de la calibraci n hecha en f brica Cuando atornille los proyectores no los ajuste demasiado 595 5292 18 PRUEBA Y AJUSTE O Prenda el cortacircuitos y el interruptor de luz O Gire el control de sensibilidad SENS a la mid y el control de tiempo ON TIME ala posici n de prueba TEST NOTA El detector tiene un per odo de cerca de 1 2 minutos de calentamiento antes de detectar movimiento Cuando lo prenda por primera vez espere 1 1 2 minutos ON TIME SENS a les gt MIN MAX 10 51 TEST Parte de abajo del detector Evite apuntar el control hacia Objetos que cambien rapidamente de temperatura tales como ductos de calefacci n y acondicionadores de aire Estas fuentes de calor pueden causar falsas alarmas Areas donde animales dom sticos o el trafico puedan activar el control Los objetos grandes cercanos y de colores resplandecientes que reflejan la luz del dia pueden hacer
17. oned too close to the sensor or pointed at nearby ob jects that cause heat to trigger the sensor Reposition the lamp away from the sensor or nearby objects Light Control is pointed toward a heat source like an air vent dryer vent or brightly painted heat reflective sur face Reposition sensor Light Control is in Manual Mode Switch to Auto Heat or light from the lamps may be turning the Light Control on and off Reposition the lamps away from the sensor Heat being reflected from other ob jects may be affecting the sensor Reposition sensor Light Control is in the Test mode and warming up Flashing is normal un der these conditions Light may be leaking through the floodlamp reflectors Replace the lamps with new high quality PAR 38 lamps TECHNICAL SERVICE Please call 1 800 858 8501 for assistance before returning product to store If you experience a problem follow this guide You may also want to visit our Web site at www desatech com If the problem persists call for assistance at 1 800 858 8501 7 30 AM to 4 30 PM CST M F You may also write to DESA Specialty Products ATTN Technical Service Specialty Products P O Box 90004 Bowling Green KY 42102 9004 If contacting Technical Service please have the following information available Model Number Date of Purchase and Place of Purchase No Service Parts Available for this Product TWO YEAR LIMITED WA
18. por un minuto y pr ndala de nuevo Despu s del tiempo de calibraci n el control estar en fase AUTO MATICA 595 5292 18 S INSTALACION Para una facil instalaci n escoja una luz con un interruptor de pared Para un mejor funcionamiento instale el aparato a casi 2 4 m del suelo O Perfore los agujeros que se necesiten para montar la placa de atr s a la caja de empalmes Montaje en pared Montaje en alero Para instalarlo bajo el alero la cabeza del detector debe ser girada como se muestra en los dos pasos siguientes para evitar el riesgo de un choque el ctrico S lo para montaje el ctrico O Gire la cabeza del detector hacia la uni n del tornillo sujetador y Controles No 0 Tornillo Sujetador O Entonces gire la cabeza del detector hacia la derecha por 180 hasta que los controles miren hacia abajo CONECTE EL CONTROL DE LUZ O Apague la energ a en el fusible o cortacircuitos O Quite el aparato de luz existente O Conecte los alambres de la caja de empalmes con los alambres del Control de Luz Unalos y aseg relos con un conector de alambre Blanco a Negro a blanco negro AA K X F o Empaquetadura INSTALE EL CONTROL DE LUZ O Alinee la placa cubertora del Control de Luz y los agujeros de la caja de empalmes Aseg relos con los tor
19. que el detector se apague No apunte otras luces hacia el detector 110 8 pies 2 4 m 60 pies 18 3 m Alcance Maximo Angulo de Cobertura Maxima El detector es menos sensible del movimiento que se dirige hacia l Movimiento Movimiento e Detector Lo menos sensible 595 5292 18 Lo m s sensible O Afloje el tornillo sujetador en la uni n esf rica y gire despacio el detector O Camine por el rea a protegerse y d se cuenta d nde est cuando se prende la luz Mueva la cabeza del detector hacia arriba hacia abajo o hacia los lados para cambiar el area de protecci n Mantenga al detector por lo menos a 1 pulgada 2 5 Tornillo Sujetador Uni n Esf rica Apunte el detector hacia abajo para poca cm de las l mparas cobertura O Fije la sensibilidad SENS como necesite Demasiada sensibilidad puede aumentar Apunte el las falsas alarmas ee mas arriba para O Asegure la punter a de la mayor cobertura cabezadeldetectorajustando el tornillo sujetador No lo apriete demasiado O Fije el per odo de tiempo ON TIME que la luz debe quedarse prendida despu s de detectar movimiento 1 56 10 minutos Advertencia Riesgo de incendio No apunte las l mparas a superficies combustibles dentro de un 3 pies 1 m ESPECIFICACIONES Alcance Hasta 60 pies 18 3 m varia de acuerdo a la temperatura que le rodea Hasta 110 Has
20. r head clockwise 180 so the controls face down WIRE THE LIGHT CONTROL Turn power off at the fuse or circuit breaker Remove the existing light fixture Route the Light Control s wires through the large gasket hole Connect the junction box wires to the Light Control wires Twist together and secure with a wire connector Q O00 Black to White to Gasket MOUNT THE LIGHT CONTROL El Align the Light Control cover plate and the junction box holes Secure with the mounting screws O If not installed on a weatherproof box or if an adaptor plate not included was used caulk the wall plate and mounting surface with silicone SS Avoid water damage and electrical shock keep lamp TK holders below horizontal a Keep lamps at least 1 25 mm from the sensor Lock nuts O Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180 from the factory setting When screwing in the floodlamps do not overtighten 595 5292 18 TEST AND ADJUSTMENT O Turn on the circuit breaker and light switch O Turn the SENSITIVITY SENS control to the mid position and the ON TIME control to the TEST position NOTE Sensor has a 1 2 minute warm up period before it will detect motion When first turned on wait 1 2 minutes
21. sponible pour ce produit GARANTIE LIMIT E DE 2 ANS Il s agit d une Garantie limit e qui vous conf re des droits juridiques sp cifiques Vous pouvez galement jouir d autres droits variables d une province l autre Pendant une p riode de 2 ans compter de la date d achat toute anomalie de fonctionnement imputable un vice de mat riau ou de main d oeuvre sera corrig e gratuitement Exclusions de la garantie R parations r glage et calibrage dus une mauvaise utilisation un mauvais traitement ou la n gligence Les ampoules les piles et des autres articles non durables ne sont pas couverts par cette garantie Le service non autoris ou la modification du produit ou d un ou l autre de ses composants fournis invalidera totalement la pr sente garantie Cette garantie n inclut pas le remboursement pour le d rangement l installation le r glage la perte d utilisation le service non autoris ou les frais d exp dition pour le renvoi de la marchandise La garantie ne couvre que les produits assembl s DESA Specialty Products et ne s tend pas aux autres quipements et composants que le client pourrait utiliser conjointement avec nos produits CETTE GARANTIE TIENT EXPRESSEMENT LIEU DE TOUTES AUTRES GARANTIES EXPLICITES OU IMPLICITES Y COMPRIS DE TOUTE GARANTIE DE REPRESENTATION OU DE CONDITION DE CONVENANCE LA COMMERCIALISATION OU L EFFET QUE LES PRODUITS CONVIENNENT A UN BUT OU UNE UTILISATION PARTICULI
22. st situ trop pr s du d tecteur ou point vers des objets etla chaleur d clenchele d tecteur Repositionnez le projecteur loin du d tecteurou des objets rapproch s La commande d clairage est point e vers une source de chaleur comme un vent une sortie de s cheuse ou une surface claire qui r fl chit la chaleur Repositionnez le d tecteur Lacommanded clairage esten mode manuel Mettez la en mode auto La chaleur ou l clairage des projecteurs peut teindre et allumer la commande d clairage Repositionnez les lampes loin du d tecteur ou des objets rapproch s La chaleur r fl chie par les objets environnants peutaffecterle d tecteur Repositionnez le d tecteur La commande est en mode test et se r chauffe Le clignotement est normal dans ces conditions La lumi re peut filtrer travers les r flecteurs des projecteurs Remplacezles projecteurs par des projecteurs neufs PAR 38 de haute qualit lev R duisez la port e SERVICE TECHNIQUE N envoyez pas de produits Si vous prouvez des difficult s suivez ce guide Vous pouvez galement crire l adresse suivante DESA Specialty Products P O Box 90004 Bowling Green KY 42102 9004 Lors d un appel au service technique veuillez avoir les renseignements suivants a port e de main num ro du mod le date d achat et endroit de l achat Aucune pi ce de rechange n est di
23. ta 300 vatios maximo de luz incandescente hasta 150 vatios maximo por cada portalamparas 120 V ca 60 Hz Angulo de sensibilidad Carga el ctrica Requisitos de potencia Modos de operaci n PRUEBA AUTOMATICO y MODO MANUAL Retardo de Tiempo 1 5 10 minutos Alcance Ajustable DESA Specialty Products se reserva el derecho de descontinuar productos y de cambiar especificaciones a cualquier momento sin incurrir en ninguna obligaci n de tener que incorporar nuevas caracter sticas en los productos vendidos con anterioridad GUIA DE INVESTIGACION DE AVERIAS SINTOMA POSIBLE CAUSA SINTOMA POSIBLE CAUSA La Luz no se enciende La luz se prende durante el dia La luz se prende sin ninguna raz n aparente No est El interruptor de luz esta apagado El faro esta flojo o fundido El fusible esta quemado o el cortacircuitos esta apagado La desconexi n de luz del dia esta en efecto Compru belo cuando comience la obscuridad Alambrado incorrecto si sta es una nueva instalaci n apuntando correctamente Apunte de nuevo el detector para proteger el rea deseada El Control de Luz puede estar instalado en un relativamente oscuro lugar El Control de Luz est en fase de Prueba Fije el interruptor del controla la posici n de TIEMPO El Control de Luz puede estar detectando animales peque os o el tr
24. tourn es vers le bas Pour montage sous avant toit seulement O Faire pivoter la t te du d tecteur en direction du joint vis de blocage Commandes o 7 Vis De Blocage O Puis faire pivoter le d tecteur sur 180 de fa on que les commandes soient tourn es vers le bas Si le d tecteur sort de la rotule desserrer la vis de blocage et r ins rer le d tecteur dans la rotule et resserrer la vis C BLAGE DE LA COMMANDE D ECLAIRAGE Couper l alimentation du circuit d clairage au fusible ou au disjoncteur Enlever l appareil d clairage existant Faire passer les fils de la commande d clairage par le trou de la garniture Torsader les fils de la bo te de jonction avec ceux de la commande d clairage Les fixer ensemble l aide de serre fils QO OO Y blanc Garniture blanc noir MONTAGE DE LA COMMANDE D ECLAIRAGE Aligner la plaque de garde de la commande d clairage et le joint la plaque d adaptation s il y alieu avec la bo te de jonction Ins rer et serrer les vis de montage Si elle n est pas mont e dans un boiter tanche ou si une plaque d adaptation est utilis e calfeutrer la plaque murale et la surface de montage avec un scellant au silicone Pour viter les dommages par l eau et les risques de choc lectrique s assurer que les douilles de lampe pointent en dessous d
25. uede necesitar una placa adaptadora Los adaptadores se pueden comprar en los Centros Comerciales para el Hogar y en las Tiendas de Aparatos El ctricos O 2004 DESA Specialty ProductsTM FUNCIONAMIENTO Modalidad tiempo encendido Trabaja Dia Noche Prueba 5 seg x x Autom 1 5610 min x Manual Hasta el x amanecer Se pone en Autom tico al amanecer Nota Cuando lo prenda por primera vez espere 1 2 minutos para que el circuito se claibre Para PRUEBA Ponga el interruptor de tiempo ON ON TIME TIME al fondo del detector en la posici n de prueba TEST 1051 TEST Para AUTOMATICO Ponga el interruptor de tiempo ON TIME ON TIME en la posici n de 1 56 10 minutos 1051 TEST Para MODO MANUAL El modo manual funciona s lo por la noche porque la luz del d a pone al detector en modo AUTOMATICO EG Apague el interruptor por un segundo y 4 segundo vu lvalo a prender para conmutar entre APAGADO MODO AUTOMATICO y MANUAL luego El modo manual funciona s lo con el interruptor ON TIME en la posici n kek 1 56 10 X pr ndalo Resumen de las modalidades del interruptor Mueva el interruptor de tiempo ON TIME a 1 56 10 minutos Apague el interruptor por un segundo y pr ndalo de nuevo MODO MANUAL Si se confunde mientras cambia de fases apague la electricidad