1. you operate the Pump and no water comes out shut the Pump off IMMEDIATELY Check the pipes for air tightness Check also that the bottom of the Inlet pipe is underneath the surface of the water and a foot valve is properly installed 1 Connect a bucket full of at least 3 gallons of water 6 to one side of the Y fitting using a hose as shown l above If available a continuous water supply such as a spigot may be used instead The bucket 7 When finished using the pump turn the Power must be positioned higher than the pump s outlet Switch off O then unplug the Power Cord Follow procedures for Storage explained below After the pump is running properly the priming hose and bucket can be disconnected Item 69304 For technical questions please call 1 800 444 3353 Page 5 1 If you will not be using the Pump for an extended 3 If you use the Pump only occasionally when period of time drain the Pump Body First disconnect you are done pumping replace the Inlet both the suction and outlet lines then tip the pump and Outlet covers to protect the unit so that all the water is drained from the pump cavity D If the Pump sits idle for a period of 5 days or more it should be unplugged and rotated with a screwdriver through the middle hole of the fan cover through several revolutions to prevent it from taking a permanent set Troubleshooting Possible Causes Likely Solutions Motor will 1 Cord not connected Check
2. Outlet Power Switch range of the rated Suction Lift The connections must Priming be airtight Wrap all threaded connections with PTFE tape sold separately 1 Remove the Inlet and Outlet Covers from the Pump 2 Attach the water source to the Inlet using appropriate methods The Inlet hose or pipe must be collapse proof to properly withstand the suction force 3 Install a foot valve and filter sold separately at the bottom of the inlet Pump Body TO PREVENT ELECTRIC SHOCK AND DEATH Make sure that the Terminal Box Cover is properly closed and sealed before priming or operation AWARNING Note A foot valve on the inlet connection is critical 2 Close the valve on the outlet side of the Y fitting and to help prevent the pump from losing prime open the valve on the priming side of the Y fitting Note Check that the water source and piping 3 Remove the Priming Plug and wait until water are clear of sand dirt and debris starts coming out of the Priming Plug Replace the Priming Plug and tighten securely 4 To start the pump a Open the valve on outlet side of the Y fitting Bucket full of clean water b Make sure your hands are dry c Plug in the pump d Turn on the Power Switch I e Close the valve on the priming side of the Y fitting CAUTION Do not run the Pump Dry Turn off the Pump IMMEDIATELY if water stops coming out the Outlet with one valve for each outlet 5 If
3. Owner s Manual amp Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions assembly operating inspection maintenance and cleaning procedures Write the product s serial number in the back of the manual near the assembly diagram or month and year of purchase if product has no number Keep this manual and the receipt in a safe and dry place for future reference ITEM 69304 PACIFIGHYDROSTAR PORTABLE SPRINKLER PUMP Visit our website at http www harborfreight com Email our technical support at tech harborfreight com PUMP IS NOT SUBMERSIBLE When unpacking make sure that the product is intact and undamaged If any parts are missing or broken AWARNING please call 1 800 444 3353 as soon as possible Copyright 2011 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in Read this material before using this product any shape or form without the express written consent of Harbor Freight Tools Failure to do so can result in serious injury Diagrams within this manual may not be drawn proportionally Due to continuing SAVE THIS MANUAL improvements actual product may differ slightly from the product described herein Tools required for assembly and service may not be included AWARNING When using electric pumps basic safety precautions should always be followed to reduce the risk of fire electr
4. alterations outside our facilities criminal activity improper installation normal wear and tear or to lack of maintenance We shall in no event be liable for death injuries to persons or property or for incidental contingent special or consequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation of exclusion may not apply to you THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the complaint must accompany the merchandise If our inspection verifies the defect we will either repair or replace the product at our election or we may elect to refund the purchase price if we cannot readily and quickly provide you with a replacement We will return repaired products at our expense but if we determine there is no defect or that the defect resulted from causes not within the scope of our warranty then you must bear the cost of returning the product This warranty gives you specific legal rights and you may also have other rights which vary from state to state 3491 Mission Oaks Blvd PO Box 6009 Camarillo CA 93011 800 444 3353 PACIFICHYOROSTAR Record Product s Serial Num
5. ber Here Note If product has no serial number record month and year of purchase instead Note Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts 3491 Mission Oaks Blvd PO Box 6009 Camarillo CA 93011 800 444 3353
6. ic shock and personal injury READ ALL INSTRUCTIONS BEFORE USING THIS PUMP 1 This Pump has not been investigated for use in Swimming pool or marine areas 2 Use only with clear water Do not use with flammable liquids such as gasoline chemicals or and corrosive liquids 3 Risk of electric shock This pump is supplied with a grounding conductor and grounding type attachment plug To reduce the risk of electric shock connect only to a properly grounded grounding type receptacle 4 If there is danger of flooding the electrical connections must be taken to higher ground 5 DO NOT IMMERSE IN WATER This is not a submersible pump Use indoors only 6 Always lock up pumps and keep out of reach of children 7 Wear ANSI approved safety goggles during installation 8 DISCONNECT POWER Unplug when not in use before servicing and when changing accessories Page 2 9 10 11 12 13 14 For technical questions please call 1 800 444 3353 CHECK DAMAGED PARTS Before using any pump check for alignment and binding of moving parts any broken parts or mounting fixtures and any other condition that may affect proper operation Any part that is damaged should be properly repaired or replaced by a qualified technician REPLACEMENT PARTS AND ACCESSORIES When servicing use only identical replacement parts Use of any other parts will void the warranty Only use accessories intended for use with this p
7. o an appropriate outlet properly installed and grounded in accordance with all codes and ordinances The plug and outlet should look like those in the preceding illustration Ee See 3 Prong Plug and Outlet 4 This pump is intended for use on a circuit that has an outlet that looks like the one illustrated above in 125 V 3 Prong Plug and Outlet The pump has a grounding plug that looks like the plug illustrated above in 125 V 3 Prong Plug and Outlet Grounding Pin 5 The outlet must be properly installed and grounded 125 V 3 Prong Plug and Outlet in accordance with all codes and ordinances for up to 125 V and up to 15 A Do not use an adapter to connect 1 Tools marked with Grounding Required have a three this pump to a different outlet wire cord and three prong grounding plug The plug must be connected to a properly grounded outlet If the tool should electrically malfunction or break down grounding provides a low resistance path to carry electricity away from the user reducing the risk of electric shock See 3 Prong Plug and Outlet Extension Cords 1 Grounded tools require a three wire extension 6 If you are using an extension cord outdoors make cord Double Insulated tools can use either sure it is marked with the suffix W A W in a two or three wire extension cord Canada to indicate it is acceptable for outdoor use 2 As the distance from the supply outlet increases 7 Make s
8. that cord is plugged in not start 2 No power at outlet Check power at outlet If outlet is unpowered turn off tool and check circuit breaker If breaker is tripped make sure circuit is right capacity for tool and circuit has no other loads Fuse is blown or breaker tripped Have fuse replaced by a qualified service technician Internal damage or wear Carbon Have serviced by a qualified service technician brushes or switch for example Motor runs 1 Improper priming Re prime according to directions but water isn t Clogged filter at end of Clean filter pumping intake connections Discharge valve closed Open discharge valve Pipe size too small Re pipe using pipe of the same size as the Pump inlet and outlet ports Impeller plugged Have Impeller cleaned by qualified service technician Pipes frozen Thaw pipes Check for damage before using pump Pump does not Corroded pipes Replace pipes deliver water at 2 Piping size too small Re pipe using pipe of the same size as full capacity the Pump inlet and outlet ports 3 Not enough water supplied to Pump 3 Enlarge inlet pipe Check well pump system 4 Low Voltage 4 Check that outlet is 120V Excessive noise Internal damage or wear Carbon Have technician service tool or rattling brushes or bearings for example Follow all safety precautions whenever diagnosing or servicing the tool Disconnect power supply before ser
9. ump Approved accessories are available from Harbor Freight Tools The pump must be protected from frost The pump must be protected from running dry Do not run the pump with the outlet closed or blocked The connections may burst due to excessive pressure WARNING Handling the cord on this product will expose you to lead a chemical known to the State of California to cause cancer and birth defects or other reproductive harm Wash hands after handling California Health amp Safety Code 25249 5 et seq Item 69304 Grounding Instructions AWARNING TO PREVENT ELECTRIC SHOCK AND DEATH FROM INCORRECT GROUNDING WIRE CONNECTION READ AND FOLLOW THESE INSTRUCTIONS Check with a qualified electrician if you are 2 The grounding prong in the plug is connected through in doubt as to whether the outlet is properly the green wire inside the cord to the grounding grounded Do not modify the power cord system in the tool The green wire in the cord must plug provided with the tool Never remove the grounding be the only wire connected to the tool s grounding prong from the plug Do not use the tool if the power cord system and must never be attached to an electrically or plug is damaged If damaged have it repaired by a live terminal See 3 Prong Plug and Outlet service facility before use If the plug will not fit the outlet have a proper outlet installed by a qualified electrician 3 The tool must be plugged int
10. ure the extension cord is properly wired you must use a heavier gauge extension cord and in good electrical condition Always replace Using extension cords with inadequately sized wire a damaged extension cord or have it repaired Causes a serious drop in voltage resulting in loss of by a qualified electrician before using it power and possible tool damage See Table A Protect the extension cords from sharp objects 3 The smaller the gauge number of the wire the excessive heat and damp or wet areas greater the capacity of the cord For example a 14 gauge cord can carry a higher current than a 16 gauge cord See Table A 4 When using more than one extension cord to make up the total length make sure each cord contains at least the minimum wire size required See Table A 5 If you are using one extension cord for more than one tool add the nameplate amperes and use the sum to determine the required minimum cord size See Table A ltem 69304 For technical questions please call 1 800 444 3353 Page 3 TABLE A RECOMMENDED MINIMUM WIRE TABLE A RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS 120 240 VOLT GAUGE FOR EXTENSION CORDS 120 240 VOLT NAMEPLATE EXTENSION CORD NAMEPLATE EXTENSION CORD AMPERES LENGTH AMPERES LENGTH at fullload 25 50 75 100 150 atfullload 25 50 75 100 150 C ro we alo Ceo a o e120 2 0 5 1 7 0 Based on limiting the line
11. vice PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND OR DISTRIBUTOR HAS PROVIDED THE PARTS DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER NOR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN FACT THE MANUFACTURER AND OR DISTRIBUTOR EXPRESSLY STATES That ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Page 6 For technical questions please call 1 800 444 3353 ltem 69304 Parts List amp Assembly Diagram Qty Item Description Qty 8 Bolt M8 14 Sealing Ring For Terminal 24 Bolt M4 8 ltem 69304 For technical questions please call 1 800 444 3353 Page Limited 90 Day Warranty Harbor Freight Tools Co makes every effort to assure that its products meet high quality and durability standards and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase This warranty does not apply to damage due directly or indirectly to misuse abuse negligence or accidents repairs or
12. voltage drop to five volts at oO Based on limiting the line voltage drop to five volts at 150 of the rated amperes 150 of the rated amperes Symbology WARNING marking concerning Risk Double Insulated of Eye Injury Wear ANSI approved safety goggles with side shields rica SP Canadian Standards Association L b Pead ihe mandar belor set up and or use UL Underwriters Laboratories Inc WARNING marking concerning O Risk of Hearing Loss V Volts Alternating Current Se Wear hearing protection WARNING marking Amperes concerning Risk of Fire Do not cover ventilation ducts No Load Revolutions per Minute RPM Risk of Electric Shock Properly connect power cord to appropriate outlet Specifications Electrical Rating 1120 V 60 Hz 10A 1215 GPH Maximum Suction Lift 26 FT 147 FT Pressure its C C dCL 7 1 PS Inlet and Outlet Diameter 1 IN NPT Power Cord Length FT AWTERTE Listed Page 4 For technical questions please call 1 800 444 3353 Item 69304 WARNING This is NOT a submersible pump Do not immerse in water Pipe Connection The Pump uses 1 NPT piping sold separately 4 Attach the outlet connection to the Outlet A Y fitting Purchase the necessary length of pipe including any with dual valves sold separately is helpful for needed fittings and bends Mount the Pump as close priming the pump see next section to the source of water as possible and within the

Download Pdf Manuals

image

Related Search

Related Contents

Benq MS502  scanCONTROL Demo-Software 1.5 - Micro  SF-320α  Fiche Technique Enovit  Descargar ficha de producto  Frigidaire 12 cu. ft. / 340 liter Upright Freezer FFU12C2A  LEYBOLD DIDACTIC GMBH Mode d`emploi 516 21 Instrucciones de  Samsung YP-S3AL دليل المستخدم  Curtis FRW062  ALIMENTATORI DC Agilent E361xA 60W SERIE BENCH MANUALE  