Home
Hampton Bay H200 User's Manual
Contents
1. 3 Do not burn any quantities of paper gar bage and never burn flammable fluids such as gasoline naptha or engine oil in your stove 4 Ifyou have smoke detectors prevent smoke spillage as this may set off a false alarm 5 Do not overfire heater If the chimney con nector flue baffle or the stove top begin to glow you are overfiring Stop adding fuel and close the draft control Overfiring can cause extensive damage to your stove including warpage and premature steel corrosion Overfiring will void your warranty 6 Do not permit creosote or soot build up in the chimney system Check and clean chimney at regular intervals Failure to do so can result in a serious chimney fire 7 Your Hampton stove can be very hot You may be seriously burned if you touch the stove while it is operating keep children clothing and furniture away Warn children of the burn hazard 8 The stove consumes air while operating provide adequate ventilation with an air duct or open a window while the stove is in use 9 Do not connect this unit to a chimney flue serving another appliance 10 Do not use grates or andirons or other methods for supporting fuel Burn directly on the bricks 11 Open the draft control fully for 10 to 15 seconds prior to slowly opening the door when refuelling the fire 12 Do not connect your unit to any air distribu tion duct 13 Your woodstove should burn dry standard firewood only The use of
2. Ways to Prevent and Keep Unit Free of Creosote 1 Burn stove with the draft control wide open for about 10 15 minutes every morning during burning season 2 Burn stove with draft control wide open for about 10 15 minutes every time you apply fresh wood This allows the wood to achieve the charcoal stage faster and burns up any unburned gas vapours which might otherwise be deposited within the system 3 Only burn seasoned wood Avoid burning wet or green wood Seasoned wood has been dried at least one year 4 A small hot fire is preferable to a large smouldering one that can deposit creosote within the system 5 Thechimney and chimney connector should be inspected at least once every two months during the heating season to determine if a creosote buildup has occurred 6 Have chimney system and unit cleaned by competent chimney sweeps twice a year during the first year of use and at least once a year thereafter or when a significant layer of creosote has accu mulated 3mm 1 8 or more it should be removed to reduce the risk of a chimney fire WOOD STORAGE Store wood under cover such as in a shed or covered with a tarp plastic tar paper sheets of scrap plywood etc as uncovered wood can absorb water from rain or snow delaying the seasoning process Hampton H200 Cast Freestanding Woodstove 25 MAINTENANCE FRONT DOOR GASKET If the front door gasket requires replacement 5 8 diameter mat
3. FOR USE WITH SOLID WOOD FUEL ONLY USE OF OTHER FUELS MAY DAMAGE HEATER AND CREATE A HAZARDOUS CONDITION DO NOT OBSTRUCT COMBUSTION AIR OPENINGS OPERATE ONLY WITH FIREBRICKS IN PLACE OPERATE ONLY WITH DOOR CLOSED OPEN FEED DOOR TO FEED FIRE ONLY DO NOT USE GRATE OR ELEVATE FIRE BUILD WOOD FIRE DIRECTLY ON HEARTH DO NOT OVERFIRE IF HEATER OR CHIMNEY CONNECTOR GLOWS YOU ARE OVERFIRING INSPECT AND CLEAN CHIMNEY AND CONNECTOR FREQUENTLY UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAPIDLY KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL AWAY FROM HEATER REPLACE GLASS ONLY WITH NEOCERAM GLASS COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON COMBUSTIBLE MATERIAL EXTENDING BENEATH THE HEATER AND TO THE FEB MAR APR FRONT AND SIDES AS INDICATED OR TO THE NEAREST PERMITTED COMBUSTIBLE MATERIAL z OPTIONAL COMPONENT FAN 846 515 ELECTRICAL RATING VOLTS 115 60 HZ 2 AMPS lt DANGER RISK ELECTRIC SHOCK DISCONNECT POWER BEFORE SERVICING UNIT DO ROUTE POWER CORD UNDER OR IN FRONT 7 APPLIANCE COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION OUTSIDE AIR KIT AND ONE OF THE FOLLOWING DOUBLE WALL CONNECTOR INCANADA LISTED SECURITY MODEL DP OR OLIVER MACLEOD PRO VENT PV DOUBLE WALLED CONNECTOR WITH LISTED CHIMNEY SYSTEM SECURITY MODEL 52100 ICC EXCEL 2100 SUPER VENT 2100 SUPERPRO 2100 CF SENTINAL INUSA LISTED DOUBLE WALL CONNECTORS SECURITY MODEL DP SELKIRK MODEL DS OLIVER MACLEOD PRO VENT PV SIMPSON DURA
4. 1 2 3 4 Safety Precautions Do not allow ashes to build up to the loading doors Only remove ashes when the fire has died down Even then expect to find a few hot embers Please take care to prevent the build up of ash around the start up air housing located inside the stove box near the pilot Never start a fire if the ash plug and ash drawer are not in place This will cause overfiring which can cause excessive warp ing of the stove Evidence of overfiring can void the warranty on your stove The firebricks are brittle and can be damaged if the plug is replaced carelessly or pieces that are too large are forced through the hole 1 2 3 Optional Ash Drawer Operating Guideline Only clean ashes out of the stove when the unit has cooled down Remove the plug by lifting on the handle using the tool provided The plug may still be warm use caution Push the ashes down the hole into the ash drawer the large pieces can be left in the firebox and burned during the next fire or removed through the door opening Ash Plug Ash Plug Tool Always leave 1 2 to 1 inch of ash in the bottom of the firebox This helps in easier starting and a more uniform burn of your fire To remove the drawer slide it out When the drawer is completely out slide the cover plate over the ash drawer and carry away 4 5 44 Slide cover plate over Ash Drawer When emptying the ash drawer m
5. Mantel Height from finished floor 48 1219 mm Note Floor Protection must extend 2 50mm Max Mantel Depth 12 305 mm to each side of the elbow 10 Hampton H200 Cast Freestanding Woodstove INSTALLATION FLOOR PROTECTION Acombustible floor must be protected by non combustible material like tile concrete board or certified to UL 1618 or as defined by local codes extending beneath the heater and a minimum of 6 from each side and minimum 16 from the front face of the stove and minimum 6 or the rear clearance to combustibles whichever is smaller from the rear of the stove When installed with horizontal venting non combustible floor protection must beneath the flue pipe and extend 2 51mm beyond each side A minimum of a 1 2 thick thermal floor protector with a 0 84k factor is required when installing the standard or optional short legs This applies to both Canada and the US All other require ments ie hearth size remain the same NOTE In Canada floor protection must extend 18 450mm to the front and 8 200mm to each side and back of the stove Residential Close Clearance Residential C Vent H200 US 43 1092 mm 6 152 mm 43 1092 mm H200 Canada 45 Minimum Overall Width X of Floor Protector for all installations 36 914 mm US 40 1016 mm Canada 6 152 mm 43 1092 mm 45 8 203 mm 45 8 203 mm 1143 mm 11
6. SAFETY LABEL This is a copy of the label that accompanies NOTE Hampton units are constantly being each Hampton H200 Freestanding Woodstove improved Check the label on the unit and if We have printed a copy of the contents here _ there is a difference the label on the unit is the for your review correct one LISTED SPACE HEATER SOLID FUEL TYPE ALSO DO NOT REMOVE THIS LABEL SUITABLE FOR MOBILE HOME INSTALLATION o 290 ul Tooled Listed By Oregon USA MODEL HAMPTON CAST FREESTANDING WOOD STOVE H200 TESTED TO UL 1482 ULC S627 00 REPORT NO 219 S 09 2 INSTALLAND USE ONLY INACCORDANCE WITH THE MANUFACTURER S INSTALLATION AND OPERATINGINSTRUCTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA USE 150 MM 6 IN DIAMETER MINIMUM 24 MSG BLACK OR 26 MSG BLUED STEEL CONNECTOR WITH LISTED UL103 HT FACTORY BUILT CHIMNEY SUITABLE FOR USE WITH SOLID FUELS OR MASONRY CHIMNEY SEE LOCAL BUILDING CODE AND MANUFACTURER S INSTRUCTIONS FOR PRECAUTIONS REQUIRED FOR PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING DO NOT PASS CHIMNEY CONNECTOR THROUGH COMBUSTIBLE WALL OR CEILING DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE MINIMUM CLEARANCES TO MEASURE FLUE FROM HEATER CENTER LINE RESIDENTIAL INSTALLATION USING SINGLE WALL CONNECTOR SIDEWALL A 431 mm 17 in D 737 mm 29 in BACKWALL B 381
7. that your unit is secured to the floor by using the bolt down holes inside the legs the same ones used in Mobile Home installations 11 For residential installations using 6 152mm Vent single wall the chimney connector must be at least 24 gauge steel Do not use galvanized pipe refer to the Mobile Home installation section 12 Do not connect this unit to chimney serving another appliance 13 connector cannot pass through an attic or roof space closet or similar concealed space or a floor ceiling wall or partition of combustible construction In Canada if passage through wall or partition of combustible construction is desired the installation shall conform to CAN CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment 14 Your Hampton Woodstove is not to be con nected to any air distribution duct Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer birth defects or other reproductive harm MODULAR INSTALLATION OPTIONS OPTIONS These can be installed at time of installation or added later Modular Option Blower Fan Outside Air Adaptor Side Shelves Things to consider when choosing options Adding the blower will increase the area heated by the stove it can move warm air beyond the room where the stove is installed refer to the Optional Blower Fan Installation section Helps combus
8. 299 GASKET 3 8 WIDE X 3 16 15 902 579 VERMICULITE LEFT THICK 37 220 065 REAR HEAT SHIELD TOP 16 200 351 LH SIDE CHARCOAL GREY 38 220 064 REAR HEAT SHIELD BOTTOM 200 355 LH SIDE TIMBERLINE BROWN 17 200 341 RH SIDE CHARCOAL GREY 200 345 RH SIDE TIMBERLINE BROWN 18 200 960 BRICK SET 19 200 110 FIREBOX FRONT 20 200 160 ANDIRON X2 21 200 120 FIREBOX INNER 22 200 217 BRACKET HINGE 23 200 361 FRONT VENTS CHARCOAL GREY 200 365 FRONT VENTS TIMBERLINE BROWN 24 200 381 FRONT SKIRT CHARCOAL GREY 200 385 FRONT SKIRT TIMBERLINE BROWN 25 220 042 SKIRT BRACKET X2 28 Hampton H200 Cast Freestanding Woodstove PARTS LIST Hampton H200 Cast Freestanding Woodstove PARTS LIST 30 8 9 PART 200 218F 200 219F 200 220F 940 345 P 936 243 936 232 200 371 200 375 220 546 948 158 220 089 10 220 046 11 948 153 12 904 018 13 904 525 14 904 751 15 948 155 16 948 163 200 DOOR ASSEMBLY DESCRIPTION GLASS RETENTION TOP GLASS RETENTION SIDE x2 GLASS RETENTION BOTTOM x2 GLASS 5mm NEOCERAM GLASS GASKET 5 8 GRAPHITE DOOR GASKET DOOR CHARCOAL GREY DOOR TIMBERLINE BROWN DOOR HANDLE ASSEMBLY SLOTTED SPRING TENSION PIN DOOR
9. Note 1 With your location already established cut and frame the roof hole It is recommended that no ceiling support member be cut for chimney and support box installation If it is necessary to cut them the members must be made structurally sound 2 Install radiant shield and support from above 3 Stack the insulated pipe onto your finish support to a minimum height of 3 feet above the roof penetration or 2 feet above any point within 10 feet measured horizontally There must be at least 3 feet of chimney above the roof level 2 ft 0 6 m Minimum ft 0 9 m Minimum Note Ridge 10 ft 3 0 m Increasing the chimney height above this minimum level will sometimes help your unit to breathe better by allowing a greater draft to be cre ated This greater draft can decrease problems suchas difficult start ups back smoking when door is open and dirty glass It might be sufficient to initially try with the minimum re quired height and then if problems do arise add additional height at a later date 4 Slide the roof flashing over your chimney and seal the flashing to the roof with roofing compound Secure the flashing to your roof with nails or screws 5 Place the storm collar over the flashing sealing the joints with a silicone caulking 6 Fasten the raincap with spark screens if required to the top of your chimney 7 For optimum efficiency when installing into a masonry chimney
10. 43 mm 1143 mm Mobile Home Close Clearance 6 152 mm 43 1092 mm 8 203 mm 45 8 203 mm 1143 mm 6 152 mm How To Determine If Alternate Floor Protection Materials Are Acceptable The specified floor protector should be 3 8 Step b 18mm thick material with a K factor of Calculate R of proposed system 0 84 4 brick of C 1 25 therefore Rbrick 1 C 1 1 25 0 80 1 8 mineral board of k 0 29 therefore Rmin bd 1 0 29 x 0 125 0 431 Total R Rbrick Rmineral board 0 8 0 431 1 231 The proposed alternative is 4 100mm brick with a C factor of 1 25 over 1 8 3mm mineral board with a K factor of 0 29 Step a Use formula above to convert specification Step c to R value Compare proposed system R of 1 231 to R 1 k x T 1 0 84 x 75 0 893 specified R of 0 893 Since proposed system R is greater than required the system is acceptable DEFINITIONS Thermal Conductance C Btu W hr ft m K Thermal Conductivity k Btu inch W Btu hr ft F m K hr fEeF Thermal Resistance R f XANEF Btu Hampton 200 Cast Freestanding Woodstove 11 INSTALLATION STEP BY STEP CHIMNEY AND CONNECTOR INSTALLATION These are a generic set of chimney in stallation instructions Always follow the manufacturers own instructions explicitly check the Minimum Rec ommended Flue Heights section
11. HAMPTON www hampton fire com Freestanding VWoodstove S Installation Manual MODEL 200 Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference 918 427a FIREPLACE PRODUCTS INTERNATIONAL LTD 6988 Venture St Delta BC Canada V4G 1 4 04 04 08 Thank you for purchasing a HAMPTON FIREPLACE PRODUCT The pride of workmanship that goes into each of our products will give you years of trouble free enjoyment Should you have any questions about your product that are not covered in this manual please contact the HAMPTON DEALER in your area Keep those HAMPTON FIRES burning SAFETY NOTE If this woodstove is not properly installed a house fire may result For your safety follow the instal lation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit HATIOMAL r i FIBER ACE We recommend that our products be INSTITUTE installed and serviced by professionals who are certified in the 0 5 by the ONE REGENCY ONE TREE National Fireplace Institute NFI For each Regency sold or in Canada by UM we plant a tree Energy Technical fid ood Energy AmericanForests org Technical Train
12. IONAL SIDE SHELF INSTALLATION 1 Secure 2 Support Gussets to each Side Shelf using 2 screws per 4 Mount side shelf to stove and secure in place using the allen key gusset provided to secure the 2 set screws Underside of Side Shelf Shown NOTE Ensure that the Bracket cut out is towards the back of the stove Bracket Cut Out Support Gussets 2 Secure the Brackets to the middle of the Side Shelves using 2 screws and washers Underside of Right Hand Side Shelf Shown Bracket Cut Out NOTE When mounting the side shelf ensure that the gusset closest to the frontofthe stove is against the top ofthe Side Casting and NOT against the side of the Front Casting This 3 will help with alignment when the stove top is put back in place Right Bracket Gusset Side Casting Front Casting Left side of stove shown Left Bracket 5 Place top back on stove Bracket Cut Out 3 Remove stove top 20 Hampton H200 Cast Freestanding Woodstove INSTALLATION OPTIONAL ASH DRAWER KIT INSTALLATION NOTE This option is only available with use of standard legs 1 Remove the andirons and bricks from within the firebox 4 Re install bottom tray and then install the 2 ash drawer rails to the bottom tray using 4 bolts Andiron 5 Slide the ash drawer on top of the rails making sure the cover is in Bricks the open position Ash Drawer in open position 3 Remove the ash dump cover plates one
13. LATCH SPACER DOOR HANDLE 1 4 FLAT WASHER x 5 8 O D 1 4 LOCK WASHER 1 4 20 x 4 1 2 HEX HEAD HINGE PIN CANE BOLT LATCH LH Hampton H200 Cast Freestanding Woodstove PARTS LIST H200 ASH DRAWER ASSEMBLY PART DESCRIPTION 200 911 ASH DRAWER PACKAGE 1 942 110 ASH PLUG 2 936 236 1 2 ROPE GASKET 3 200 232 ASH DRAWER GUIDE RIGHT 4 200 231 ASH DRAWER GUIDE LEFT 5 820 249 ASH PLUG TOOL HANDLE Hampton H200 Cast Freestanding Woodstove 31 PARTS LIST 32 PART 200 917 220 026 910 157 910 142 H200 FAN ASSEMBLY DESCRIPTION FAN ASSEMBLY PACKAGE FAN HOUSING FRONT FAN HOUSING BOTTOM SENSOR MOUNT FAN BRACKET RIGHT HAND FAN BRACKET LEFT HAND FAN HOUSING BACK FAN THERMODISC Hampton H200 Cast Freestanding Woodstove NOTES Hampton H200 Cast Freestanding Woodstove 33 5 34 Hampton 200 Cast Freestanding Woodstove WARRANTY HAMPTON Hampton Fireplace Products are designed with reliability and simplicity in mind In addition our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility FPI Fireplace Products International Ltd is pleased to extend this limited lifetime warranty to the original purchaser of a Hampton Product This warranty is not transferable The Warranty Limited Lifetime H200 H300 Firebo
14. SECURITY 2100 SUPERVENT 2100 Roof Support 6PLRS 12 BK ICC EXCEL 2100 SUPERPRO 2100 Flashing CF SENTINAL Chimney Length Chimney Length Rain Cap 6PL MPC The use of alternate pitch flashings support box extensions additional chimney lengths and additional chimney bracing may be used on each of the previously listed systems These parts though must be from the same system as listed and must be a similar and or compli mentary part Description Connector Kit CAUTION At no time use unlabelled parts or substitute parts made for another chimney system Description 48 Chimney length also in 12 18 24 lengths Rain Cap Round Ceiling Support Install as per chimney manufacturer s Flashing installation instructions Close Clearance Connector ICC EXCEL 2100 Qty Part 1 6CL48 6RC 6RCS 6RDS SQS 6VF 6UBA Description 48 Chimney length also in 12 18 24 lengths Rain Cap Spark Screen for rain cap Round Square support box Flashing Ultrablack Close Clearance Connector Hampton H200 Cast Freestanding Woodstove 17 INSTALLATION BRICK INSTALLATION Firebrick is included to extend the life of your stove and to radiate heat more evenly Check to see that all firebricks are in their correct positions and have not become misaligned during shipping Optional Ash Plug shown DOOR REMOVAL 1 Open door 2 Push spring lever down while holding onto the d
15. SHING CEILING JOIST 4 INCH CLEARANCE Tr WITH FIRE STOP tt X EAVE SS 4 CLEARANCE COMBUSTIBLE WA THIMBLE 12 INCHES OF BRICK i SHEATHING 10 FLOOR PROTECTOR TY AIRTIGHT nr 1 sj CLEANOUT DOOR aM gt m att T Support Plate amp Clamp BIA Listed Rigid Stainless Liner Fireclay liner 5 8 16mm Minimum or 2 Equivalent Carry Stovepipe Stainless Steel Above the Liner Flex Section BUS We Stainless Tee with Cleanout Damper Plate is TAS Removed or Stainless Connector Pipe Position pain EL Y L i E FO Use Damper Adapter or Seal With Sheetmetal and Sealant Cleanout II GR ER Hampton H200 Cast Freestanding Woodstove 13 INSTALLATION COMBUSTIBLE WALL CHIMNEY CONNECTOR PASS THROUGHS Method A 12 304 8 mm Clearance to Combustible Wall Member Using a minimum thickness 3 5 89 mm brick and a 5 8 15 9 mm minimum wall thickness clay liner construct a wall pass through The clay liner must conform to ASTM C315 Standard Specification for Clay Fire Linings or its equivalent Keep a minimum of 12 304 8 mm of brick masonry between the clay liner and wall combustibles The clay liner shall run from the brick masonry outer surface to the inner surface of the chimney flue liner but not past
16. SHORT LEGS 23 7 8 606mm GAS ON COE rT 20 12 25 1 8 639mm 25 5 8 574mm 20 3 8 519 21 533mm 24 610mm 22 5 8 575mm 23 3 4 602 CZ II TS NENNEN 5 8 E Hampton H200 Cast Freestanding Woodstove INSTALLATION PRE INSTALLATION ASSEMBLY After removing the stove from its packing open the front door and remove the contents from the firebox leaving the bricks in place Draft Control Lever Handle 1 Insert bolt and lock washer through draft control lever hole 2 Place handle through bolt Tighten to se cure Bolt Washer Handle Draft Control Lever Hampton H200 Cast Freestanding Woodstove Rotating Elbow 3 Slide the tabs on the rear heat shield in This stove be connected to either top or rear vent exit by simply reversing the orientation Please Note The shield needs to be stretched of the elbow flexed in order to fit in place Simply remove the 2 screws change the position of the elbow as desired and secure in place with screws Slide tabs in between Rear Heat Shield washer and bolt 4 Once rear heat shield is evenly in place Rear Heat Shield tighten bolts to secure Used only on Vertical Installations 1 Loosen the bolts that secure the elbow to the unit Ensure elbow does not fall off 2 Bendthe tabs onthe rear heat shield inwards 90 d
17. VENT MODEL DVL GSW SUPER PIPE 6 METAL FAB DOUBLE WALL CONNECTED TO ONE OF THE FOLLOWING COMPATIBLE CHIMNEY SYSTEMS SECURITY MODEL 52100 OR MODEL ASHT SELKIRK MODEL SSII OLIVER MACLEOD PRO JET 3103 SIMPSON DURA PLUS GSW MODEL SC OR METAL FAB TEMP GUARD AMERI TECHS ICC EXCEL 2100 SIMPSON DURA PLUS HTC USE CHIMNEY COMPONENTS AS SPECIFIED IN INSTALLATION INSTRUCTIONS MANUFACTURED BY FPI FIREPLACE PRODUCTS INTERNATIONAL LTD H 6988 VENTURE ST DELTA BC V4G 1H4 UNITED STATES ENVIRONMENTAL CERTIFIED TO COMPLY WITH JULY 1990 PROTECTION AGENCY PARTICULATE EMISSION STANDARDS CAUTION HOT WHILE IN OPERATION DO NOT TOUCH KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS READ NAMEPLATE AND INSTRUCTIONS 918 4282 DATE OF MANUFACTURE 2008 C 2009 7 2010 7 4 Hampton H200 Cast Freestanding Woodstove INSTALLATION UNIT DIMENSIONS WITH STANDARD LEGS 23 7 8 606mm gt 5 C C er E E Z 2 D gt 15 z N d O LO 27 5 8 703mm 28 3 4 729mm em 181mm Hampton H200 Cast Freestanding Woodstove 5 INSTALLATION UNIT DIMENSIONS WITH OPTIONAL
18. ake sure the ashes have cooled down com pletely Ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a non combustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the closed container until all cinders have thoroughly cooled Other waste should not be placed in the ash container Before putting the ash drawer backin ensure that the ash plug is back in place 24 Hampton H200 Cast Freestanding Woodstove MAINTENANCE MAINTENANCE It is very important to carefully maintain your stove including burning seasoned wood and maintaining aclean stove and chimney system Have the chimney cleaned before the burning season and as necessary during the season as creosote deposits may build up rapidly Moving parts of your stove require no lubrication GLASS INSTALLATION REPLACEMENT 1 Remove door from unit 2 Toreplace the glass remove the 12 screws highlighted in the diagram below 3 Lift off the glass retainer and carefully re move glass 4 Place new glass in the door make sure that the glass gasketing will properly seal your unit 5 Position the glass retainer back on En sure that it rests on the gasket and not the glass 6 Secure glass retainer using the 12 screws Do not wrench down on th
19. anent outside air source for combustion 3 The stove must be electrically grounded to the steel chassis of the Mobile Home 4 A listed double wall connector chimney system roof thimble spark arrestor and roof flashing kit suitable for use in Mobile Homes must be used 5 If the chimney exits the Mobile Home ata location other than through the roof and exits at a point 7ft 2130mm or less above the ground level on which the Mobile Home is positioned a guard or method of enclosing the chimney shall be fitted at the point of exit for a height up to 7ft 2130mm 6 The chimney shall be attached directly to the room heater and shall extend at least 3 ft 914mm above the part of the roof through which it passes The top of the chimney should project at least 2ft 610mm above the highest elevation of any part of the Mobile Home within 10 ft 3048mm of the chimney 7 Thechimney system shall comply with Local Requirements 8 Any openings in chimney guard where required must not permit the entrance of 3 4 19mm diameter rod 9 CAUTION THE STRUCTURAL INTEG RITY OF THE MOBILE HOME ROOF FLOOR WALLS AND CEILING MUST BE MAINTAINED 10 Check any other local building code as other local codes may apply 11 WARNING DO NOT INSTALLINASLEEP ING ROOM OF A MOBILE HOME 12 Use silicone to create an effective vapour barrier at the location where the chimney or other component penetrates to the exterior of the s
20. cut lumber ply wood mill ends etc is not allowed as this fuel can easily overheat your woodstove Evidence of excessive overheating will void your warranty As well a large portion of sawmill waste is chemically treated lumber which is illegal to burn in many areas Salt drift wood and chemically treated fire logs also must not be burned in your wood stoves 14 Do not store any fuel closer than 2 feet from your unit Do not place wood paper furniture drapes orother combustibles near the appliance 15 WARNING Do not operate without the Ash Plug properly seated 16 Do not operate with broken glass DRAFT CONTROL Both the primary and air wash drafts are control led by the control handle located onthe right side of the unit when facing the unit To increase your draft push lever to the back and to decrease pull lever to the front All units have a secondary draft system that continually allows combustion air to the induction ports at the bottom of the firebox just below the rear cover Front Closed Back Open WARNING To build a fire with disregard to the information contained in this section can cause serious permanent damage to the unit and void your war ranty Hampton H200 Cast Freestanding Woodstove 23 OPERATING INSTRUCTIONS ASH DISPOSAL During constant use ashes should be removed every few days The Ash Drawer features a convenient ash drawer for easy removal of ashes
21. de mismatch door or glass gasketing or trim At no time will be liable for any consequential damages which exceed the purchase price of the unit FPI has no obligation to enhance or modify any unit once manufactured ie as products evolve field modifications or upgrades will not be performed FPI will not be liable for travel costs for service work Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the terms of this warranty policy Refractory liners firebrick gaskets door handles paint are not covered under the terms of this warranty policy Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy The warranty will not extend to any part which has been tampered with or altered in any way or in our judgment has been subject to misuse improper instal lation negligence or accident spillage or downdrafts caused by environmental or geographical conditions inadequate ventilation excessive offsets negative air pressure caused by mechanical systems such as furnaces fans clothes dryer etc Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer FPI will not be liable for acts of God or acts of terrorism which cause malfunction of the appliance Performance problems due to operator error will not be covered by this warrant
22. e glass as this may cause the glass to break 7 Place door back on unit Remove 12 screws Glass Retainer GLASS MAINTENANCE Your Hampton stove is supplied with 5 mm Neoceram ceramic glass Part 940 345 that will withstand the highest heat that your unit will produce Inthe event that you break your glass by impact purchase your replacement from an authorized Hampton dealer only and follow our step by step Glass Installation Replacement instructions refer to previous section It will be necessary to clean carbon and fly ash off of the glass at times If carbon and fly ash remain on the glass for an extended period of time the glass could eventually become etched and cloudy 1 Allow the stove to cool down completely before cleaning the glass do not clean the glass when it is hot 2 Use cleaners specifically designed for this glass cleaning Do not use abrasive clean ers 3 Ensure the glass is dry before burning your stove CREOSOTE When wood is burned slowly it produces tar and other organic vapours which when combined with moisture form creosote The creosote va pours condense in the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote can result in an extremely hot fire WARNING Things to remember in case of a chimney fire 1 Close all draft and damper controls 2 CALL THE FIRE DEPARTMENT
23. egrees Bend tabs inwards 90 degrees INSTALLATION 1 2 3 4 5 6 RESIDENTIAL INSTALLATION Please read this entire manual before you install and use your new woodstove Failure to follow instructions may result in property damage bodily injury or even death Be aware that local Codes and Regulations may override some items in this manual Check with your local inspector Select a position for your Hampton Stove Consult the minimum clearance chart for your model and set the stove in place For close clearance installation use listed double wall connector systems To insure vertical alignment suspend a plumb bob from the ceiling over the exact center of your stove flue and mark a spot on the ceiling to indicate the center of the chimney Check that the area above the ceiling is clear for cutting Re confirm the clearance from the stove to combustibles to insure that they are within the prescribed limits This woodstove must be connected to a UL 103 HT ULC S629 listed chimney or a code approved masonry chimney with a flue liner from the ceiling and beyond Install chimney according to chimney manu facturers instructions The performance of your woodstove is governed to a very large part by the chimney system Too short a chimney can cause difficult start up dirty glass backsmoking when door is open and 7 8 even reduced heat output Too tall a chimney may prompt excessive draf
24. erial must be used Hampton uses a 5 8 diameter gasket Part 936 232 A proper high temperature gasket adhesive is required See your Hampton Dealer HANDLE REPLACEMENT 1 Remove handle front or side by undoing the hex head bolt using a 7 16 socket wrench 2 Fit new door handle over latch and se cure Assembly shown below Hex Head Front Door Handle Shown me Secure using 7 16 socket wrench LATCH ADJUSTMENT METHOD The door bracketry may require adjustment as the door gasket material compresses after a few fires Removal of the spacer washer will allow the latch to be moved closer to the door frame causing a tighter seal Relocate the washer removed from the back of the bracket to the front This will allow the same screw to be used Use the 3 16 allen key enclosed in the packaged manual to make this adjustment Front of Bracket Remove spacer washers behind screws Allen Key If position of bracketry needs to be changed after adjustment The bracketry should start from the highest point as seen below If needed bring the bracketry down 1 16 each time until finding the best locking position The door latch will catch best in this way Listen for a double click sound when the door is locked Bracketry at highest position Front of Bracket 26 Hampton H200 Cast Freestanding Woodstove MAINTENANCE 3 Remove the left and right baff
25. ing CERTIFIED Training WETT 2 Hampton H200 Cast Freestanding Woodstove TABLE CONTENTS SAFETY LABEL NS I I6 4 UNIT DIMENSIONS Unit Dimensions with Standard Legs 5 Unit Dimensions with Optional Short Legs 6 INSTALLATION Pre installation Assembly Residential 8 Modular Installation Options 8 Minimum Clearance To Combustible Materials 9 Minimum Alcove Clearance To Combustible Materials 10 Additional Clearances For Backwall Exit 10 Floor d gn 11 Step by Step Chimney and Connector Installation 12 Factory Built ChiMNney a dete io adaidun 12 Masonry Chimie uesuauaseud2xiidinic i gcc abad ausu satus 13 Masonry 13 Combustible Wall Chimney Connector 14 Recommended Heights For Woodstove Flue 15 Mobile Home Installation 16 Listed Components For Mobile Home Installat
26. ing 2 bolts CAUTION Moving parts may cause injury Do not operate unit with blower housing removed T Tighten DANGER Risk of electric shock Discon bolts nect power before servicing unit Grounding lt 8 Groung Lug Lug Detail Ground wire EE NUL fom fan Lockwasher SS ET 6 3 Loosen the 2 bolts you see after remov ing back shield on each side of the SS stove Groundwire from power cord Star washer Star washer Back Shield WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock 7 Using the 3 screws from the fan cover plate secure the fan assembly to the back shield hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug 8 Plug in power cord Green Manual 120V AC Auto Switch H 60 Hz CAUTION Label all wires SPUM prior to disconnection when servicing controls Fan Thermodisc normally open Wiring errors can cause improper and dangerous operation i E UJ D Q 2 2 NOTE INPUT POWER Australia New Zealand China and Japan use 240V AC 50 Hz 1 Blower Fan Wiring Diagram Hampton H200 Cast Freestanding Woodstove 19 INSTALLATION OPT
27. inside the firebox and one on the underside of the firebox by removing the 2 nuts and bolts holding the 2 plates together from underneath the stove 6 Push the ash plug into the hole inside the firebox and re install the bricks and andirons P Ash Plug Hampton H200 Cast Freestanding Woodstove 21 OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS With your unit now correctly installed and safety inspected by your local authority you are now ready to start a fire Before establishing your first fire it is important that you fully understand the operation of your draft control See below First Fire section for details FAN OPERATION Automatic To operate the optional fan automatically push the bottom switch on the side of the fan housing to AUTO and the top switch to either HIGH or LOW for fan speed This will allow the fan to turn on as the stove has come up to operating temperature It will also shut the fan system off after the fire has gone out and the unit cooled to below a useful heat output range Manual To manually operate the fan system push the bot tom switch to MAN and the top switch to either HIGH or LOW This will bypass the sensing device and allow full control of the fan Switching from AUTO to MAN or HIGH to LOW may be done anytime FIRST FIRE When your installation is completed and spected you are ready for your first fire 1 Open control fully 2 Ope
28. ion 17 Briek InstallattOJ Luise 18 Door SIO EE T 18 Optional Short Leg Installation 18 Optional Blower Fan Installation 19 Optional Side Shelf Installation 20 Optional Ash Drawer Kit Installation 21 Hampton H200 Cast Freestanding Woodstove OPERATING INSTRUCTIONS Operating Instructions NITE 22 Fan 22 SLEEP EN 22 Safety Guidelines And Warnings 29 D Ce 23 Ash 24 Glass 25 MAINTENANCE Maintenance 25 Glass Installation Replacement 25 Creosote EE ee ne ne 25 219 2 25 Front Door Ec 26 Handle 26 Latch Adjustment 2 2 2 22 1 26 Top Baffle 27 PARTS LIST H200 Main 28 H200 Door ASSembyuu nusnmarususrubanjeninbeaern 30 H200 Ash Drawer 31 H200 Fan Assembly aansasii rmmmnmesdnh stenene 32 WARRANTY H200 Fan Assembly 35 3
29. ized to fit and hold the metal chimney connector See that the supports are fastened securely to wall surfaces on all sides Make sure fasteners usedto secure the metal chimney connector do not penetrate chimney flue liner Method D 2 50 8 mm Clearance to Combustible Wall Member Start with a solid pak listed factory built chimney section at least 12 304 mm long with insulation of 1 25 4 mm or more and an inside diameter of 8 2 inches 51 mm larger than the 6 152 4 mm chimney connector Use this as a pass through for a minimum 24 gage single wall steel chimney connector Keep solid pak section concentric with and spaced 1 25 4 mm off the chimney connector by way of sheet metal support plates at both ends of chimney section Cover opening with and support chimney section on both sides with 24 gage minimum sheet metal supports See that the supports are fastened securely to wall surfaces on all sides Make sure fasteners used to secure chimney flue liner Minimum chimney clearance to brick and combustibles 2 in 50 8mm Minimum clearance 12 in 304 8mm of brick 7 NNN Chimney connector Chimney Flue Fire clay Minimum liner 12 in 304 8mm to combustibles Masonry chimney Minimum chimney clearance trom masonry to sheet steel supports and combustibles 2 in 50 8 mm rez Minimum clearance 9 in 228 6 mm N
30. le caps by 5 Replace the Top Baffle TOP BAFFLE removing the 2 bolts 7 16 socket 1 4 20 x REPLACEMENT 1 2 hex head on each side and lift out 6 Reverse steps 4 to 1 1 Lift the Top Hob off the top of the stove Top Hob 4 Remove the three 7 16 socket 1 4 20 x 1 2 stainless steel hex bolts inside the firebox holding the top baffle assembly and remove 2 Remove the five 7 16 socket 1 4 x 1 hex bolts from the Firebox Top Assembly and lift off Top Baffle Removed Hampton H200 Cast Freestanding Woodstove 27 PARTS LIST H200 MAIN ASSEMBLY PART DESCRIPTION PART DESCRIPTION 1 200 301 TOP CHARCOAL GREY 26 820 376 RETAINER PLATE 200 305 TOP TIMBERLINE BROWN 27 200 391 BASE CHARCOAL GREY 2 200 522 FIREBOX TOP ASSEMBLY 200 395 BASE TIMBERLINE BROWN 28 200 401 ASH LIP CHARCOAL GREY 3 200 514 BAFFLE ASSEMBLY 200 405 ASH LIP TIMBERLINE BROWN 4 200 203 BAFFLE CAP LEFT 29 820 375F ASH HOLE COVER PLATE 5 200 204 BAFFLE CAP RIGHT 6 200 140 LH BAFFLE RETENTION 30 200 206F PRIMARY AIR PROFILE PLATE 7 200 150 RH BAFFLE RETENTION 31 200 518 DRAFT LEVER CONTROL ASSEMBLY 8 220 431 45 DEGREE EXHAUST 32 200 205 PRIMARY AIR SLIDE GUIDE 9 200 224 BACK SHIELD 33 200 211 SUB BASE 10 200 225 AIR DEFLECTOR 11 200 230 FAN OPENING COVER 34 200 411 LEG CHARCOAL GREY 12 200 000 MAIN BACK 200 415 LEG TIMBERLINE BROWN 13 200 130 FIREBOX BACK 35 936 236 1 2 GRAPHITE GASKET 14 902 580 VERMICULITE RIGHT 36 936
31. llowing vertical height to compen Example b 5000 21 60 25 20 sate for One 90 deg elbow 2 ft 8000 23 76 27 72 45 deg elbow 1 ft 2 ft of horizontal run 4 ft 90 deg elbow 2ft one T 3 ft p 3 ft Total Addition at sea level 9 ft Each foot of horizontal run 2 ft 3 Add 4 overall for each 1000 above sea level TABLE 1 MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET Measured from the top of the unit OF ELBOWS ELEVATION FT 0 1000 1000 2000 2000 3000 3000 4000 4000 5000 5000 6000 6000 7000 7000 8000 8000 9000 9000 10000 NOTE more than two offsets four elbows allowed Two 45 elbows equal one 90 elbow Hampton H200 Cast Freestanding Woodstove 15 INSTALLATION MOBILE HOME INSTALLATION Once you have properly marked the position of your unit and the floor protection as outlined in the Residential Installation items 1 through 8 a supply of fresh air has to be supplied to your unit Place your unit in position and secure it to the floor using four lag bolts 1 4 through the four holes inside the legs It is important to maintain the structural integrity of the Mobile Home floor walls and roof when installing your unit For Mobile Home units installed in the U S the unit must be grounded using a 8 ground wire with approved termination and star washer CAUTION At no time use unlabelled parts or substitute parts made for another chimney system Install as
32. low over firing Stop loading fuel immediately and close the draft control until the glow has completely subsided 14 Green or wet wood is not recommended for yourunit If you must add wet or green fuel open the draft control fully until all moisture has been dispersed by the intense fire Once all moisture has been removed the draft control may be adjusted to maintain the fire 15 Ifyou have been burning your stove on alow draft use caution when opening the door After opening the damper open the door a crack and allow the fire to adjust before fully opening the door 16 The controls of your unit or the air supply passages should not be altered to increase firing for any reason 17 If you burn the unit too slowly or at too low a setting your unit will not be operating as efficiently as it can An easy rule of thumb saysthatif your glass is clean then your flue is clean and your exhaustis clean Burn the stove hot enough to keep your glass clean and you won t need to clean your flue as often 22 Hampton H200 Cast Freestanding Woodstove OPERATING INSTRUCTIONS SAFETY GUIDELINES AND WARNINGS 1 Never use gasoline gasoline type lantern fuels kerosene charcoal lighter fuel or similar liquids to start or freshen up a fire in your heater Keep all such liquids well away from the heater while it is in use 2 Keep the door closed during operation and maintain all seals in good condition
33. mm 15 in E 435 mm 17 1 8 in CORNER C 330 mm 13 in F 505 mm 19 7 8 in INSTALLATION USING LISTED DOUBLE WALL CONNECTOR MOBILE HOME SIDEWALL 381 mm 15 D 686 mm 27 in BACKWALL B 254 mm 10 E 308 mm 12 1 8 BACKWALL In Canada floor protection must extend 18 CORNER 228 mm 9 in F 403 mm 15 7 8 INSTALLATION USING LISTED DOUBLE WALL 457mm to the front and 8 200mm to each 17 G CONNECTOR RESIDENTIAL CLOSE CLEARANCE SIDEWALL A 381 mm 15 D 686 27 ADJACENT WALL BACKWALL B 254 mm 10in 308 mm 12 1 8 in BACKWALL FLOOR PROTECTION LE 457 18 150mm M 150 mm AUG TEER SIDEWALL side and back of the stove SIDEWALL JUN MAY CORNER C 228 mm 9in F 403 15 7 8 in INSTALLATION USING LISTED DOUBLE WALL CONNECTOR ALCOVE SIDEWALL 6381 15 686 mm 27 in BACKWALL H 330 mm 13 J 384 mm 15 1 8 in SIDEWALL MINIMUM ALCOVE CEILING HEIGHT 1 5 5 FT MAXIMUM ALCOVE DEPTH 1220 MM 48 IN MINIMUM CLEARANCES FOR HORIZONTAL CONNECTOR TO CEILING 457 MM 18 THE SPACE BENEATH THE HEATER MUST NOT BE OBSTRUCTED OPERATE ONLY WITH FIREBRICKS IN PLACE
34. n firebox door and build a small fire us ing paper and dry kindling on the firebrick hearth Secure door on the firebox and wait a few minutes for a good updraft in the flue to establish the fire Leaving the door slightly open will help your fire start more rapidly CAUTION Never leave unit unat tended if door is left open This procedure is for fire start up only as unit may overheat if door is left open for too long 3 With the draft still in the fully open position add two or three seasoned logs to your fire Form a trench in the ash bed to allow air to reach the rear of the firebox prior to closing the door 4 After about 45 minutes when your wood has begun to burn strongly adjust your draft control down to keep the fire at a moderate level WARNING Never build a roaring fire in a cold stove Always warm your stove up slowly 5 Once a bed of coals has been established on the firebrick hearth you may adjust the draft control to a low setting to operate the unit at its most efficient mode 6 During the first few fires keep the combus tion rate at a moderate level and avoid a large fire Only after 5 or 6 such fires can you operate the stove at its maximum setting and only after the metal has been warmed 7 For the first few days the stove will give off an odour from the paint This is to be expected as the high temperature paint becomes seasoned Windows and or doors should be left open to provide adequa
35. nit From From Flue Center Line Corner 15 381 mm 10 254 mm 9 228 mm 27 686 mm 12 1 8 308 15 7 8 403mm Mobile Home Close Clearance To be installed with required pipe components C Vent single wall pipe is not approved for Mobile Home installations refer to Mobile Home Instructions Unit with Heat Shield From Unit From Flue Center Line A B C D E F 381mm 10 254 mm 9 228mm 27 686mm 12 1 8 308mm 15 7 8 381mm Hampton H200 Cast Freestanding Woodstove 9 INSTALLATION MINIMUM ALCOVE CLEARANCE TO COMBUSTIBLE MATERIALS L 7 7777 This Hampton Freestanding model has been alcove approved and must be installed I with a listed double wall connector to the ceiling level I Note Minimum alcove ceiling height from finished floor 60 1525 mm G Maximum depth of alcove 48 1220 mm l 18 457mm From Flue Min Hearth Unit with Heat Shield Center line to Rear Wall H200 15 381 mm 13 330 27 686 mm 15 1 8 384 mm 54 1372 mm 50 1270 mm ADDITIONAL CLEARANCES FOR BACKWALL EXIT Minimum Clearance to Combustibles Unit with Heat Shield NEN AEN A B 9 228 15 381 mm 2 50 Minimum Clearance to Non Combustibles Unit with Heat Shield min 0 0 mm max 9 228 mm Min
36. onsoluble refractory cement Factory built chimney length Chimney connector Chimney length Hush with inside of flue Use chimney mirs parts to attach conmector securely Air space 9 in 228 6 mm min Chimney Solid insulated listed factory built chimney length M Masonry Chimnev Dec Sheet steel supports Minimum chimnev clearance to sheet steel supports and combustibles 2 1n 50 8 mm Two air channels each 1 in 25 4 mm Fenn Chimney connector 2 AM Minimum 1n Two ventilated air i 5 fiber insulation e 1 I 25 4 mm Masonry Chimney Construction of gt Sheet steel sheet steel supports Minimum chimney clearance to sheet steel supports and combustibles Sheet steel 2 10 aL Minimum clearance 2 1n 50 8 mm in 25 4 mm air space to chimney length Chimney connector Chimney length Exam a Masonry Sheet steel chimney supports 2 in 50 8 mm 14 Hampton H200 Cast Freestanding Woodstove INSTALLATION RECOMMENDED HEIGHTS FOR WOODSTOVE FLUE Simple rules on draft See Table 1 Example a Recommended Flue Height 1 1 2 ft of horizontal run 3 IL Elevation Example a Example b 1 At sea level minimum height is 12 one T 3 ft 0 18 21 straight Total Addition at sea level 6 ft 1000 18 72 21 84 2000 19 44 22 68 2 Add the fo
37. oor 3 Pulldoordownand lift out to remove Bottom of door lifts right out Spring Lever Bottom part of door fits into slot OPTIONAL SHORT LEG INSTALLATION 1 Remove the cast lid from the top of the stove 2 Remove fan if installed 3 Carefully lay the unit on it s back on a soft surface to prevent scratching 4 Remove the 4 standard legs by undoing the bolts Standard Leg 5 Secure the 4 short legs using the bolts removed from step 4 Short Leg 6 Carefully bring stove to standing position 7 Place cast lid back on top of stove 8 Re install fan if removed 9 Place decal 918 700 included with cast legs on the back of the stove near the serial number decal 18 Hampton H200 Cast Freestanding Woodstove INSTALLATION An optional blower is available for the Hampton OPTIONAL BLOWER FAN INSTALLATION H200 The blower is factory assembled wired and ready for attachment to the stove 1 Remove fan cover plate from back shield 4 Hook fan over the bolts This unit must be connected to a grounded by undoing 3 screws and discard plate standard 120 volts 60 Hz electrical outlet Never route the power cord under or in front of the unit Do not under any circumstances cut or remove the grounding prong from the power cord Do not use an adaptor plug NOTE For more detailed information see instructions included with the Optional Blower 2 Remove back shield by undo
38. per chimney manufacturer s installation instructions IMPORTANT DO NOT CONNECT TO OR USE IN CON JUNCTION WITH ANY AIR DISTRIBUTION DUCTWORK UNLESS SPECIFICALLY AP PROVED FOR SUCH INSTALLATIONS If desired the air for combustion may be drawn directly from the outside ofthe house as detailed below It is not obligatory to do this but it may help combustion in small or poorly ventilated house Connect a 4 100 mm diameter stainless steel or other non combustible corrosion resistant material tothe O S Ahook up box In orderto do this the O S Ahook up box mustbe connected to the base using 1 2 12 mm hex head bolts Run the pipe up to 54 1372 mm long to the outside avoiding sharp bends and joints within cavity walls Turn the end down and fit corrosion resistant mesh to prevent the entry of leaves and rodents Seal the penetration of the outside wall with silicon T Unit Bolted to eee Floor Permanent Outside Air Inlet WARNING Do not obstruct free air supply to the air inlet duct located at the back of the stove NOTE Listed factory built chimney con nectors including elbows are acceptable for use in Mobile Home Installations In addition to standard installation instructions the following requirements are mandatory for installation in a mobile home 1 The stove must be permanently bolted to the floor of the Mobile Home using the floor screws provided 2 The stove must have a perm
39. size accordingly i e the 6 152mm flue dia is 28 28 sq in 8 Tocomplete your chimney installation install the double wall connector pipe from the stove s flue collar to the chimney support device 9 If you are using a horizontal connector the chimney connector should be as high as possible while still maintaining the 18 457mm minimum distance from the hori zontal connector to the ceiling 10 NOTE Residential Close Clearance and Alcove installations require a listed dou ble wall connector from the stove collar to the ceiling level The diagrams below illustrate one way to in stall your unit into a standard ceiling or with a horizontal connector Check with your dealer or installer for information on other options available to you Rain Cap gt Chimney Storm Collar LE Sections nn A lt Roof Flashing TR Ty Roof Radiation Shield if required Ja AX t MX lt y Attic Radiation Shield Minimum Air Space in accordance with chimney listing Chimney Connector lt a 14 ce D Non Combustible Existing Floor Floor Protector Combustible Standard Ceiling Installation Rain Cap Chimney Sections Roof Radiation Shield if required Storm Collar lt Roof Flashing R Minimum Air Space in accordance with chimney listing Chimney Connector Insulated Tee Wall Support Chase Optional Non Combustible Existing Floor Floor Pro
40. t which can result in very short burn times and excessive heat output The use of an inexpensive flue pipe damper may be helpful in reducing excessive draft CAUTION The chimney should be the same size as the 6 152mm flue outlet on the stove The chimney must be listed as suit able for use with solid fuels For other types of chimneys check with your local building code officials Do not confuse a chimney with a type B Venting System used for gas appliances as suitable for a wood burning appliance refer to the Mobile Home instal lations section Mark the location of the legs on the floor then move the stove aside and mark the position of the floor protector The floor protector must be of non combus tible material and must extend 16 406mm in front of the door opening and 6 152mm to the sides and rear of the unit Some areas may require a larger size floor protector However when installing the unit with the short leg option there is a requirement of 0 84k of floor protector beneath the non combustible finished floor See your local inspector For outside air installation refer to Mobile Home installation section NOTE In Canada floor protection must ex tend 18 450mm to the front and 8 200mm to each side and back of the stove 9 When the floor protection is complete posi tion the stove with the flue collar centered under the installed chimney 10 In seismically active areas we recommend
41. te ventilation while this temporary condition exists Burning the stove at a very high temperature the first few times may damage the paint Burn fires at a moderate level the first few days 8 Do not place anything on the stove top during the curing process This may result in damage to your paint finish 9 During the first few days it may be more difficult to start the fire As you dry out your firebrick and your masonry flue your draft will increase 10 Forthose units installed at higher elevations or into sub standard masonry fireplaces drafting problems may occur Consult an experienced dealer or mason on methods of increasing your draft 11 Some cracking and popping noises may be experienced during the heating up process These noises will be minimal when your unit reaches temperature 12 Before opening your door to reload open draft fully for approximately 10 to 15 seconds until fire has been re established This will minimize any smoking 13 All fuel burning appliances consume oxygen during operation It is important that you supply a source of fresh air to your unit while burning A slightly opened window is sufficient for the purpose If you also have a fireplace in your home a downdraft may be created by your Hampton Stove causing a draft down your chimney If this occurs slightly open a window near your unit CAUTION If the body of your unit flue baffle or any part of the chimney connector starts to g
42. tector Combustible Horizontal Installation FACTORY BUILT CHIMNEY When a metal prefabricated chimney is used the manufacturer s installation instructions must be followed You must also purchase and install the ceiling support package or wall pass through and section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clearance to the structure as recommended by the manufac turer The chimney must be the required height above the roof or other obstructions for safety and proper draft operation 12 Hampton H200 Cast Freestanding Woodstove INSTALLATION MASONRY CHIMNEY Ensure thata masonry chimney meets the minimum standards ofthe National Fire Protection Association NFPA by having it inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed and operated When connecting the stove through a combustible wall to a masonry chimney special methods are needed Refer to page 13 for Combus tible Wall Chimney Connector Pass Throughs MASONRY FIREPLACE There are listed kits available to connect a stove to a masonry fireplace The kit is an adapter that is installed at the location of the fireplace damper The existing damper may have to be removed to allow installation ml FIRECLA Y FLUE LINER CONCRETE CAF A WITH AIRSPACE ANS RAFTER en FLA
43. the consumer from FPI after the original coverage has expired on the unit will carry 90 day warranty valid with a receipt only Any item shown to be defective will be repaired or replaced at our discretion No labor coverage is included with these parts Conditions Porcelain Enamel Absolute perfection is neither guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection Any part or parts of this unit which in our judgement show evidence of such defects will be repaired or replaced at FPI s option through an accredited distribu tor or agent provided that the defective part be returned to the distributor or agent Transportation Prepaid if requested It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to FPI and evaluated for manufacturer defect The authorized selling dealer is responsible for all in field service work carried out on your Hampton product will not be liable for results or costs of workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective Exclusions This limited Lifetime Warranty does not extend to or include paint charcoal units porcelain including pinholes scratches and minor sha
44. the inner surface Firmly grout or cement the clay liner in place to the chimney flue liner Method B 9 228 6 mm Clearance to Combustible Wall Member Using a 6 152 4 mm inside diameter listed factory built Solid Pak chimney section with insulation of 1 25 4 mm or more build a wall pass through with a minimum 9 228 6 mm air space between the outer wall of the chimney length and wall combustibles Use sheet metal supports fastened securely to wall surfaces on all sides to maintain the 9 228 6 mm air space When fastening supports to chimney length do not penetrate the chimney liner the inside wall of the Solid Pak chimney The inner end of the Solid Pak chimney section shall be flush with the inside of the masonry chimney flue and sealed with a non water soluble refractory cement Use this cement to also seal to the brick masonry penetration Method C 6 152 4 mm Clearance to Combustible Wall Member Starting with a minimum 24 gage 024 61 mm 6 152 4 mm metal chimney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing fiberglass insulation from the outer surface of the wall thimble to wall combustibles Support the wall thimble and cover its opening with a 24 gage minimum sheet metal support Maintain the 6 152 4 mm space There should also be a support s
45. tion in small or poorly ventilated houses Installation instructions come with adaptor Add to the traditional look of the stove and double as warming area for your cookstove creations Ash Drawer Adding the ash drawer will allow for easier removal and transport of ashes Helps in reducing the overall height of the unit to accomodate variety of installations Using this option prohibits the use of the ash drawer Short Legs Hampton H200 Cast Freestanding Woodstove INSTALLATION MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS Please read the section below carefully Measurements From Unit are from the top plate of the stove to a side wall or to a corner and from the rear heat shield to a back wall Clearances may only be reduced by means approved by the regulatory authority NOTE Be aware that local Codes and Regulations may override some clearances listed in this manual Check with your local inspector Residential Installation C Vent Single Wall Unit with Heat Shield From Unit From From Flue Center Line Corner 17 431 mm 15 381 mm 13 330 mm 29 737 mm 17 1 8 435 mm 19 7 8 505mm Residential Close Clearance To be installed with required pipe components When the stove is installed as close clearance residential unit a listed double wall connector is required from the stove collar to the ceiling level Unit with Heat Shield From U
46. tructure 16 Hampton H200 Cast Freestanding Woodstove INSTALLATION U S Installation METALBESTOS SSII Qty Part Description 1 6DS VK Connector Kit 1 6TMH Shield Support 1 6TAF 6 Flashing 1 61 36 Chimney Length 1 61 18 Chimney Length 1 6 Rain Cap PRO JET 3103 Qty Part Description 1 PV06 TK Connector 1 CSB Shield Support 1 RRS Radiation Shield 1 LFR03 Flashing 1 53 Chimney Length 1 SL1 Chimney Length 1 RCSA Rain Cap SECURITY ASHT Qty Part Description 1 DL42A 6 Connector Kit 1 6SS Shield Support 1 6FAMH Flashing 1 6L3 Chimney Length 1 6L1 Chimney Length 1 CPE Rain Cap SECURITY 52100 Qty Part Description 1 DL42A 6 Connector Kit 1 6XSF Support 1 6XFA Flashing 1 6XL3 Chimney Length 1 6XL18 Chimney Length 1 6XCPE Rain Cap METAL FAB TEMP GUARD 2100 Qty Part Description 1 6DWBK Connector 1 6TGRS Roof Support 1 6TGG36 Chimney Length 1 6TGG12 Chimney Length 1 G6TGF Flashing 1 6TGC Rain Cap LISTED COMPONENTS FOR MOBILE HOME INSTALLATION The Hampton H200 Cast Freestanding unit is approved for installation in a Mobile Home if one of the following pipe systems is used AMERI TECHS Qty Part 1 6DCC 1 6HSRS 12 6F 6HS 36 6HS 18 6HS RCS SIMPSON DURA PLUS Qty Part 1 6DVL8693 1 6DP MH9096 Mobile Home Kit SIMPSON DURA PLUS HTC Qty Part 1 C9013SS C9084 C9045 C9049 8685 _ Canadian Installations Description Connector
47. x castings on all Hampton Wood burning Appliances are covered against manufacturer defects for a period of three 3 years parts subsidized labour and a further two 2 years parts only Stainless steel baffles are covered against manufacturer defects for a period of three 3 years parts and subsidized labour and parts only thereafter 00 Steel fireboxes to be free from defects in materials and workmanship also covered are vermiculite baffles and air tubes against warpage against manufacturer s defects for a period of 3 years parts and subsidized labor and parts only thereafter External casting not directly in contact with the fire such as hobs sides side shelves ash lips legs fronts fire doors and surrounds are covered against cracks and warps resulting from manufacturer defects parts and subsidized labour for three 3 years from the date of purchase and parts only thereafter Glass is covered for lifetime against thermal breakage only parts and subsidized labour for three 3 years and parts only thereafter from date of pur chase Blowers and electrical are covered against manufacturer defect for two years parts and one year subsidized labour from date of purchase Replacement blowers are considered repairs and continue as if new with appliance ie twelve 12 months from original purchase date of appliance with a minimum of three 3 months coverage from date of replacement Repair replacement parts purchased by
48. y policy Subsidy according to job scale as predetermined by Hampton H200 Cast Freestanding Woodstove 35 Hampton fireplace products are designed with reliability and simplicity in mind In addition our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door Fireplace Products International Ltd 15 pleased to extend this Limited Lifetime Warranty to the original purchaser of a Hampton Product See the inside back cover for details Register your Hampton online at http www hampton fire com Installer Please complete the following information Dealer Name amp Address Installer Phone Date Installed D 1 u 1 a BAN L T3 ie 5 1 ET Ja Serial No 4 1 7 Tu GQQ L