Home
Guardian Technologies GGU300 User's Manual
Contents
1. HOSE CRADLE amp HOSE ASSEMBLY HOSE CRADLE ASSEMBLY Set hose cradle on the top of the cleaner Fig 1 Using a Phillips screwdriver secure the 3 4 inch screw HOSE ASSEMBLY Insert the body end of hose into the hose hole on the top of the cleaner Fig 2 Line up circular tab on hose cuff with inner groove Fig 2 Connect and twist clockwise to secure proper hose connection Fig 3 Place hose in hose cradle Fig 4 Insert the base end of the hose into the hose inlet on the base of the cleaner Fig 5 Fig 3 Base Hose Connector AGA Fig 4 HANDLE ASSEMBLY HANDLE DISASSEMBLY HANDLE ASSEMBLY Insert handle in the handle hole on the top of the body Fig 6 Push the handle removal button Pull handle upward Protrusion to lock Handle Hole Handle _ Removal Button BASE ASSEMBLY BASE ASSEMBLY Set the body on the top of the base Fig 7 Use both sides of the guide feature on the base BASE DISASSEMBLY Push the release canister pedal Lift up the body Release Canister Pedal Guides CONVERTING TO CANISTER MODE cont Push handle removal button and pull up on handle to disconnect from body Fig 13 Insert hose into handle hose connector and twist clockwise to lock in position Fig 14 Crevice Push button on wand to extend telescoping wand Fig 14 Tool Insert end of handle into hard floor nozzle F
2. Cleaner won t run 1 i se Power cord not firmly plugged into outlet Motor protector tripped Need service 1 Plug unit in firmly 2 Cool down and press the reset button See page 3 Take to service center or call 1 866 603 5900 oo Brushroll won t spin A ow Pp Cleaner is not in the upright mode Brush switch is off Brushroll is jammed Belt is broken or off motor pulley 4 The brush only turns on when the handle is released for vacuuming The brush does not come on in the upright position even if the switch is on Depress handle for brushroll to start turning See page 5 Make sure the brush switch is in on Remove it and clean debris hair etc off of brush then replace Replace the new belt or correct belt securing See page 10 ao N A Cleaner or tool won t pick up dirt D D Sz Incorrect height setting Hose not attached to base Clogged hose Dirt cup is full Inner filter is blocked Crack or hole in hose Rotate setting knob to correct height setting See page 7 Grasp hose tube and firmly push onto base Try to remove clog by squeezing out of hose Empty dirt cup See page 8 if washed after dried well reinsert it Clean it or replace new See page 9 MN oe A Sz ep Take to service center or call 1 866 603 5900 Cleaner is d
3. when it becomes dirty Fig 24 Use filter FLTA for exhaust filter Caution This filter is not washable Filter Frame Filter Exhaust Filter Fig 23 Note Replacement parts can be purchased by calling 1 866 603 5900 BELT REPLACEMENT wang Before replacing the belt make sure the cleaner is unplugged from electrical outlet Turn off the cleaner and unplug from electrical outlet Remove the bottom plate of the base by removing the 5 screws using a Phillips screwdriver Fig 25 Set the new belt over motor pulley Fig 26 Use belt BLT1 Slip the brushroll into the belt and reassemble Fig 27 Replace the bottom plate and secure the 5 screws HEADLIGHT REPLACEMENT Turn off the cleaner and unplug from electrical outlet Press the handle release pedal and use the handle to place the body in a flat position Remove the headlight cover by removing the screw with Phillips screwdriver Fig 28 Pull the bulb straight out of the socket Fig 29 Install the new bulb model LBU Replace the headlight cover and secure the screw Headlight Cover A PE Note Replacement parts can be purchased by calling 1 866 603 5900 10 TROUBLESHOOTING GUIDE Please check each item below if you have trouble with your cleaner Before checking ensure that the cleaner is unplugged from the power supply PROBLEM PROBLEM SOLUTION
4. LIMITED WARRANTY To the consumer Guardian Technologies LLC warrants this product to be free of defects in materials or workmanship commencing upon the date of the original purchase Refer to your product carton for the length of warranty and save your original sales receipt to validate start of warranty period If this product should become defective within the warranty period we will repair or replace any defective parts free of charge The complete machine must be delivered pre paid to any authorized Guardian Technologies LLC warranty service center Please include complete information on the problem day of purchase copy of original sales receipt and your name address and telephone number If you are not near a warranty station call the factory for assistance in the US and Canada at 1 866 603 5900 Use only genuine Guardian Technologies replacement parts The warranty does not include unusual wear damage resulting from accident or unreasonable use of the product This warranty does not cover unauthorized repairs This warranty gives you specific legal rights and you may also have other rights other rights may vary from state to state in the U S A We consider the registration process important to ensuring superior service to our customers however submitting this card to Guardian Technologies LLC is optional and does not affect your rights to utilize this warranty according to the conditions stated above If you have any questions or comme
5. LTERS TO CLEAN OR REPLACE DO NOT OPERATE VACUUM WITHOUT FILTERS WARNING DO NOT USE SHARP OBJECTS TO CLEAN OUT THE HOSE SINCE THEY COULD CAUSE DAMAGE OCCASIONALLY REMOVE BRUSHROLL AND REMOVE DEBRIS FROM END CAPS TO ENSURE BRUSHROLL ROTATES SMOOTHLY WARNING THE CORDS WIRES AND OR CABLES SUPPLIED WITH THIS VACUUM CONTAIN CHEMICALS INCLUDING LEAD OR LEAD COMPOUNDS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM WASH HANDS AFTER USING WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY Do not leave appliance when plugged in Unplug vacuum from wall outlet when not in use and before servicing or performing any maintenance on the unit Do not use outdoors or on wet surfaces Electrical shock could occur Do not use as a toy Close attention and supervision is necessary when used by or near children Use only as described in this manual Use only manufacturer s recommended attachments and replacement parts such as filters belts and headlights Do not use with damaged cord or plug If vacuum is not working as it should has been dropped damaged left outdoors or dropped in water return it to the manufacturer for service or call 1 866 603 5900 for more information Do not pull or carry by cord use cord as a handle close a door on a cord vacuum over the cord pull the cord around sharp corners or edges Keep cord away from heated surfaces Do not unplug by pulling
6. e cleaner store in upright mode Store accessories on the storage clips located on the cleaner body Wrap the cord around the cord storage hooks on the side of the body and hang the plug at the cord clip on the wand Fig 18 Fig 18 CLEANING DIRT CUP You will need to empty dirt cup when dust reaches the FULL line Turn off the cleaner and unplug from electrical outlet Grasp the dirt cup handle and depress button pull out the dirt cup from body Fig 19 To empty remove the dirt cup and hold over trash bin Push the dirt release button and dispose of the dirt Fig 20 Dirt Cup Fig 19 Fig 20 CLEANING amp REPLACING FILTER To optimize the vacuum performance you should clean the filter each time you empty the dirt cup Lift up the dirt cup cover rotate and remove the inner filter Fig 21 Tap the inner filter on a trash bin to remove the dust from the pleats Fig 22 Note This inner filter is washable and can be rinsed if you notice a reduction in vacuum performance suction To wash first tap filter to remove excess dirt and dust from the pleats Rinse filter clean with warm water then allow to completely dry a minimum of 24 hours before returning to dirt cup Use filter FLTB for inner dirt cup Inner Filter Fig 21 Fig 22 EXHAUST FILTER CLEANING amp REPLACEMENT Pull out the exhaust filter Fig 23 Replace the exhaust filter
7. ifficult to push zk MN Incorrect height setting Brush switch is off Rotate height setting knob to correct height setting See page 7 Make sure the brush switch is in on MN Visible dust escaping from cleaner k MN oo Dirt cup is full Filter missing or installed incorrectly Dirt cup installed incorrectly Empty dirt cup See page 8 wash it after dried well replace it Check inner filter amp exhaust filter for correct installation Pull out and re insert dirt cup correctly N oe 11
8. ig 15 Canister mode Fig 16 TOOL ASSEMBLY Attach crevice tool dusting brush and upholstery brush into storage area on the back of the vacuum Fig 8 t L E Dusting Fig 8 Brush UPRIGHT MODE USING IN UPRIGHT MODE Push the handle release pedal Fig 9 Turn main power switch on Turn brush power switch on Caution The headlight and brush does not come on when in the upright position even if the switch is on You must release the handle for the brushroll to begin spinning Fig 10 7 Base Safety Handle Removal Button A Handle _ Hose Connector Telescoping Button Switch Fig 13 Fig 14 Fig 9 Fig 10 CONVERTING TO CANISTER MODE CONVERTING TO CANISTER MODE vo Remove hose from base hose connector Fig 11 n Step on release canister pedal and pull body upward by canister handle Fig 12 Hard Floor Canister 4 A amp Handle Base Hose D Release f Ft N A Connector A Canister 4 Pedal Fig 11 Fig 12 Nozzle Fig 15 Dirt Cup Release Button HEIGHT ADJUSTMENT KNOB Rotate the height adjustment knob to the correct carpet height Fig 17 To clean bare floor set this knob to the bare floor position and turn off the brush power switch Located on the top of the Cleaner see page 2 Fig 17 HEIGHT ADJUSTMENT KNOB KY bA o KS vox e s STORING After using th
9. nts about our product call toll free at 1 866 603 5900 or send comments to Attn Customer Service Guardian Technologies LLC 7700 St Clair Avenue Mentor OH 44060 Warranty registration is also available online at www guardiantechnologies com Guardian Technologies LLC 7700 St Clair Avenue Mentor Ohio 44060 1 866 603 5900 www guardiantechnologies com 2010 Guardian Technologies LLC pureguardian guardiantechnologies com pureguardian 2 in 1 l Upright amp Canister with Silver Clean Technology USE amp CARE INSTRUCTIONS Replacement Parts HEPA Dirt Cup Filter FLTB Exhaust Filter FLTA Belt Style BLT1 English Manual E 1 French Manual F 1 Spanish Manual S 1 ZAWARNING Cleaner assembly may include small parts Small parts can present a choking hazard Upright to Canister Model No GGU300 1 Year Limited Warranty www guardiantechnologies com 1 866 603 5900 REVO411 THIS VACUUM CLEANER IS INTENDED FOR HOUSEHOLD USE ONLY IMPORTANT SAFETY INSTRUCTIONS When you use an appliance basic precautions should always be followed Please read the entire manual before using this appliance READ ALL INSTRUCTIONS BEFORE USE ALWAYS FOLLOW SAFETY INSTRUCTIONS BRING VACUUM TO AN UPRIGHT POSITION IF NOT USING IN CANISTER MODE TO USE THE HOSE AND ATTACHMENTS DO NOT LEAVE VACUUM CLEANER UNATTENDED WHEN PLUGGED IN REGULARLY CHECK FI
10. on cord To unplug grasp the plug and not the cord Do not handle plug or vacuum with wet hands Do not put any objects into openings Do not use vacuum with any openings that are blocked Keep all Openings free of dust lint hair and anything that may reduce air flow Keep loose hair clothing fingers and all parts of the body away from openings and moving parts Keep animals away from openings and moving parts Do not pick up anything that is burning or smoking such as cigarettes matches or hot ashes Do not use without dirt cup container and filters in place If the vacuum is not working as it should please call customer service at 1 866 603 5900 or visit www guardiantechnologies com Turn off all controls before unplugging Use extra care when cleaning on stairs or under furniture Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present Keep the vacuum cleaner on the floor Only hand held vacuum cleaners may be set on furniture Do not use an extension cord with this vacuum Store the vacuum indoors Put the vacuum away after use to prevent tripping accidents Using improper voltage may result in damage to the motor and possible injury to the user Proper voltage is listed on the data label located on the vacuum cleaner SAVE THESE INSTRUCTIONS ZAwarnine To reduce the risk of electric shock this vacuum cleaner has a polarized plug one blade i
11. s wider than the other This plug will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician to install the proper outlet Do not change the plug in any way 2 PLEASE READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE WARNING Do not use the Dirt Cup Handle to move the cleaner Thermal Reset Button Operates due to over heating caused by a full dirt cup clogged filter or blocked pipes Unplug the cleaner and remove the blocked materials To operate again after cooling down the cleaner about 30 minutes press the thermal reset button GGU300 Cord Length 120V 60Hz Inner Filter Amperage Exhaust Filter Weight Net Headlight Dimensions LxWxH 15 x 14 x 45 25 ganar alacraiac a Handle 9 ___ Cord Clip Main Power Brush Power a a N Switch Switch Handle Handle Hose r A Connector z 7 Extension O Button q g 7 Handle Hole Mc Hose Hole Canister A SY a Handle K WIZ A UU Dirt Cup i f PA o Q DirtCupHandle f Body we Removal Button Ww Height Adjustment Knob _ U Base Hose l A Connector r Release Canister Pedal Headlight Reset Button Plug SY m 3 4 Phillips Hard Floor Nozzle Crevice Tool Dusting Brush Upholstery Brush Head Screw