1. Inspect all components If damage is evident please notify the carrier and your Graham Field equipment provider 750000 INS LAB RevC11 11 PUMP AND MATTRESS INSTALLATION 1 Place the mattress on top of the bed frame ensure that the foot end symbol faces up at foot end as shown at right 2 Fold open the wire hangers on the back of the pump as shown at right 3 Either hang the pump on the bed s foot end as shown at right or place the pump on a flat surface easily accessible to the user caregiver and or doctor A NOTICE Place the device in a position where the user Caregiver and or doctor can access it easily 4 Connect the mattress pump air hose quick connector ensure that the connector has clicked securely into place before continuing A NOTICE Ensure that the air hoses are not kinked or tucked under the mattress 12 750000 INS LAB RevC11 Z WARNING Locate all cords so that they will not be stepped on tripped over or otherwise subjected to damage or stress Z WARNING Do not use a household extension cord if the electrical cord does not reach the power outlet Use of an improper extension cord could result in fire and electric shock If an extension cord must be used use a three conductor cord with ground properly wired in good electrical condition and keep it as short as possible Z WARNING Ensure that the local power voltage is appropriate for the pump unit 5 Plug the po
2. pressure adjust knob controls the air pressure output Turn it clockwise to increase output pressure firmer turn it counter clockwise to decrease air output pressure softer Higher pressure output will better support the heavier weight user The setting is measured in kilograms kg Please consult your physician for an appropriate setting Normal pressure indicator The green normal pressure LED illuminates when the pressure inside the air mattress has reached the selected pressure setting Low pressure indicator The yellow low pressure LED illuminates when the pressure inside the air mattress is below the selected setting 750000 INS LAB RevC11 9 Static function switch Press the static function switch to suspend alternating function if needed the pressure inside the air tubes will then be adjusted to identical pressure Press the static function switch again to change back to alternating mode The static function switch toggles between static and alternating modes Main power switch The main power switch toggles between ON and OFF When power is ON either the normal or low pressure indicator illuminates 10 750000 INS LAB RevC11 INSTALLATION UNPACKING 1 Before unpacking check for obvious damage to the carton or its contents If damage is evident please notify the carrier and your Graham Field equipment provider 2 Remove all loose packing from the carton 3 Carefully remove all components from the carton 4
3. surface such as a bed or couch where the openings may be blocked Keep the air opening free of lint hair and other similar particles Z WARNING Connect this product only to a properly grounded power outlet Z WARNING Maximum patient weight capacity for this product is 350 Ib 159 kg 750000 INS LAB RevC11 5 WARNING Patient entrapment with bed side rails may cause injury or death The bed frame and its components including the mattress bed side rails head and foot board bedding and any accessories added to the bed can all affect the risk of entrapment Thorough patient assessment and monitoring are necessary to reduce the risk of entrapment including establishing whether the use of a bed rail is in the best interest of the patient Read and understand the User Manual before using this equipment GF Health Products Inc product manuals are available online at www grahamfield com Visit the FDA s Bed Safety page at www fda gov to learn more about the risks of entrapment It is the responsibility of the facility and provider to be in compliance with these guidelines Refer to user manuals for beds and rails for additional product safety information After any adjustment repair or service and before use ensure all attaching hardware is securely tightened Bed rails with dimensions different than the original equipment specified by the bed manufacturer may not be interchangeable and may result in entrapment or other
4. If a product is deemed to be under warranty GF Health Products Inc shall provide at its option 1 replacement of any defective part or product or 2 a credit of the original selling price made to GF Health Products Inc s initial customer The warranty does not include any labor charges incurred in replacement part s installation or any associated freight or shipping charges to GF Health Products Inc The warranties contained herein contain all the representations and warranties with respect to the subject matter of this document and supersede all prior negotiations agreements and understandings with respect thereto The recipient of this document hereby acknowledges and represents that it has not relied on any representation assertion guarantee warranty collateral contract or other assurance except those set out in this document 750000 INS LAB RevC11 19 USA Corporate Headquarters GF Health Products Inc 2935 Northeast Parkway Atlanta Georgia 30360 telephone 770 368 4700 fax 770 368 2386 GRAHAM FIELD www grahamfield com 2011 GF Health Products Inc
5. LUMEX A Graham Field Brand AltaDyne 750000 ALTERNATING PRESSURE LOW AIR LOSS MATTRESS SYSTEM Important Do not operate the Mattress System Without first reading and understanding this manual Save this manual for future use Info The most current version of this manual can be found online at www grahamfield com 0000 INS LAB RevC11 CONTENTS INTRODUCTION ssscsssssunc aassanaansenntnaaassannegaannannc ncansnnnegeannannenatannnnnest 3 INTENDED USE OF THIS DEVICE un nisrsrnennnnnnnnes 3 CONTRAINDICATION ccccseeeeseeeseeeeseeessnensseeeenseesneeeeneeesenenenes 3 IMPORTANT SAFETY PRECAUTIONS ni ssnnnnmrnnnnnnte 4 DANGER oaee aeaea aaee Saana Ea ea aaea aaaea aaa iaaa iaaa aaaea 4 WARNING WE 5 NOTICE RE A A E E 6 EQUIPMENT SYMBOLS nn tereSEEREEEEEEFEEEEEEEEEREREEEEEERRRREEEEEESEREEEEEESSEREEEEEEER 7 PRODUCT DESCRIPTION ssemrrrnnannenmnnnnnnnmnnnnnnnennnnnnnn ee 8 PUMP AND MATTRESS SYSTEM scssssseseeesseeeseeeeseneeseneneneenesenees 8 PUMP d Lal UE 8 PUMP REAR TTT 9 PUMP TOP PANEL ejssisctsesteiscceswad covassuddcvaasedtnenssudcetuasiduuunscudssvadereue 9 INSTALLATION sssicsssnrinccnnsarecasnenmnnannsacenetndianeennaneamereasauaaecenneuaues 11 UNPACKING nrernnnmennnennnnennnnnenenennnnennnnennnnnnnnenennnennnnennns 11 PUMP AND MATTRESS INSTALLATION nisnrinennennner 12 OPERATION nn rrrrensnrrrmnnnnnanmenennnannnnnnnnnnnnenennnnnnnnnnennnennennne 14 PRESSURE ADJUSTMENT inissirenenmennnnnsnn
6. ergent The mattress may also be cleaned using a 10 solution of sodium hypochlorite bleach diluted in water Air dry all parts thoroughly before use A NOTICE Do not use phenolic products to clean the mattress A NOTICE After cleaning air dry the mattress without direct exposure to sunlight GENERAL MAINTENANCE 1 Check main power cord and plug for abrasion or excessive wear 2 Check mattress cover for signs of wear or damage Ensure mattress cover and tubes are connected correctly 3 Check airflow from the air hose connector The airflow should alternate between each connector every half cycle time if it s in alternating mode 4 Check the air hoses for any kink or break For replacement please contact your GF equipment provider 16 750000 INS LAB RevC11 Fuse replacement tool needed small screwdriver 1 If you suspect a blown fuse disconnect the plug from the wall outlet immediately 2 Use a small screwdriver to remove the cover of the fuse holder fuse locations are shown in picture at right 3 Insert a new fuse of the correct rating T1A 250V VDE approved 4 Replace the fuse holder cover Air filter replacement 1 Remove the air filter plate located at rear of pump filter location shown in picture at right 2 Remove the filter The filter is reusable if not torn and can be washed gently with a mild detergent and water Dry the filter before use 3 Replace the air fil
7. essure by placing four fingers below the mattress 14 750000 INS LAB RevC11 under the patient s buttock area your fingers should just fit If the fit is too loose decrease the setting If your fingers do not fit well increase the setting two notches firmer Wait ten minutes and then check again You should only have to adjust this setting one time per patient Please consult your physician for an appropriate setting QUICK DISCONNECT Pull the power plug from the wall connector to disconnect the device quickly TRANSPORT CAP In case of power failure or transport Disconnect the quick connector and cap the mattress with the transport cap to slow deflation CPR FUNCTION 4 If CPR must be performed on the patient while the mattress is in use to immediately deflate the mattress either 1 Pull the CPR valves from the ug mattress in the location of the arrow shown at right or VI connector transport cap 2 Disconnect the quick connector from the pump in the location of the arrow shown at right 750000 INS LAB RevC11 15 MAINTENANCE CLEANING Perform the following cleaning procedures before use Pump Wipe the pump with a clean damp cloth and mild detergent and keep it away from dust Air dry A NOTICE Do not use phenolic products or corrosive or powdered cleansers to clean the pump A NOTICE Do not immerse or soak the pump Mattress Wipe the mattress unit with a clean damp cloth and mild det
8. injury NOTICE A NOTICE The pump can be used only with the accompanying mattress Do not use it for any other purpose 6 750000 INS LAB RevC11 EQUIPMENT SYMBOLS A Attention Consult accompanying documents this manual BF symbol Indicates that this product is in accordance with the degree of protection against electric shock for type BF equipment _ Functional earth for UL only o Class II for UL only this product please consult your local city office household waste disposal service or Graham Field equipment provider Disposal of Electrical amp Electronic Equipment WEEE Do not treat this product as household waste For more detailed information with regard to returning and recycling For U S and Canada only Medical Equipment Air Pump E228589 with respect to electrical shock fire and 53DG US mechanical hazards only in accordance with UL60601 1 and CAN CSA C22 2 No 601 1 750000 INS LAB RevC11 7 PRODUCT DESCRIPTION PUMP AND MATTRESS SYSTEM foot end symbol M valves mattress mattress pump connectors pump and mattress system Pump front Yo g vi connector 8 750000 INS LAB RevC11 Bump rear Pump top panel Lr function switch Static main power switch n E OFF B i Power 1 Normal Pressure son Pam Cl Low Pressure L pressure indicator normal pressure indicator pressure adjustment knob Pressure adjust knob The
9. nnnnnnnes 14 QUICK DISCONNECT au e eseeereee eg eege ENEE ES 15 TRANSPORT CAP 2 cccsseceseeeeseeeeseeeeseeeeseeeeneeeeneneensneesenenssneeeneenenenees 15 CPR FUNCTION E 15 MAINTENANCE 0 cccseeceeseeeeeeeeeeenneeeseseeeneeseeseneeeeseseeeeeeseeseeneenenseeenenens 16 CLEANING ed nent ananas eme tend nn ere a use aies 16 GENERAL MAINTENANCE nnnnnnnnrrsnrersnrennnnmnnnenennnnennenennnnennnnes 16 FUSE REPLACEMENT sccssessseeesseeeseeeessneeseeeneneeeeseeesenenenees 17 AIR FILTER REPLACEMENT 2 cssseessseresseeeseeeeseneessnenensenensnees 17 CH Kei 17 SPECIFICATIONS sssssanssnncuansenancceannssnneeanansonecannsenncanannaneneannsscaeeanns 18 WARRANTY sissoscesticssscisctercssavindsesannsscetiasstasesiessassedenrsssasetedavsasdccatsvasescaadd 19 Graham Field Lumex and AltaDyne are registered trademarks of GF Health Products Inc GF Health Products Inc Graham Field is not responsible for typographical errors Packaging warranties specifications and products are subject to change without notice 2 750000 INS LAB RevC11 INTRODUCTION Use this manual for set up and operation of the Lumex AltaDyne 750000 Alternating Pressure Low Air Loss Mattress System Read all instructions before using the mattress system Save this manual for future reference INTENDED USE OF THIS DEVICE The intended use of the Lumex AltaDyne 750000 Alternating Pressure Low Air Loss Mattress System is The treatment of p
10. perty damage Info Provides application recommendations or other useful information to ensure that you get the most from your product DANGER To reduce the risk of electrocution Z DANGER Always unplug this product immediately after using Z DANGER Do not use this product while bathing A DANGER Do not place or store this product where it can fall or be pulled into a tub or sink Z DANGER Do not place this product in or drop into water or other liquid Z DANGER Do not reach for a product that has fallen into water Unplug it immediately 4 750000 INS LAB RevC11 WARNING To reduce the risk of burns electrocution fire or personal injury A WARNING Do not leave this product unattended when plugged in A WARNING Always use close supervision when this product is used by on or near children or those who require close supervision A WARNING Use this product only as intended and described in this manual Do not use attachments or accessories not recommended by Graham Field A WARNING Never operate this product if a It has a damaged cord or plug b It is not working properly c It has been dropped or damaged d It has been dropped into water Return the product to your Graham Field equipment provider Z WARNING Keep the cord away from heated surfaces Z WARNING Never drop or insert any object into any opening or hose Z WARNING Never block the air openings of this product or place it on a soft
11. ressure ulcers while optimizing user comfort Pain management as prescribed by a physician As described above in either a homecare or long term care setting Contraindication A WARNING DO NOT use this product in the presence 750000 INS LAB RevC11 of flammable anesthesia There is a possible fire hazard when this product is used with certain oxygen delivery equipment Use nasal cannula face mask or 1 2 length oxygen tent to deliver oxygen in the presence of this product DO NOT use a full length oxygen tent that extends past the top surface of the mattress with this product IMPORTANT SAFETY PRECAUTIONS The safety statements presented in this chapter refer to the basic safety information that should be observed by those using the Alternating Pressure Low Air Loss Mattress System There are additional safety statements in other chapters or sections which may be the same as or similar to the following or specific to the operations Z DANGER Indicates an imminent hazard situation that if not avoided will result in death or serious injury Z WARNING Indicates a potential hazard situation or unsafe practice that if not avoided could result in death or serious injury Z CAUTION Indicates a potential hazard or unsafe practice that if not avoided could result in minor or moderate personal injury A NOTICE Indicates a potential hazard or unsafe practice that if not avoided could result in product or pro
12. ter regularly if it is gray torn or the environment is dirty STORAGE 1 Lay the mattress out flat and upside down 2 Roll from the head end toward the foot end 3 Stretch the foot end strap around the rolled mattress to prevent unrolling 4 Store mattress and pump in a dust free environment with no exposure to direct sunlight A NOTICE Do not fold crease or stack the mattress 750000 INS LAB RevC11 17 SPECIFICATIONS Pump Specification Power Supply 120V System AC 120V 60 Hz Info see rating label on product Fuse Rating T1A 250V Air input gt 4LPM Dimensions L x W x H 9 8 x 5 3 x 3 7 25 x 13 5 x 9 5 cm Weight 4b 1 8 ko Temperature Operation 50 F to 104 F 10 C to 40 C Storage 5 F to 122 F 15 C to 50 C Shipping 5 F to 158 F 15 C to 70 C Humidity Operation 10 to 90 non condensing Storage 10 to 90 non condensing Shipping 10 to 90 non condensing Classification Class II Type BF IPXO Applied Part Air Mattress Not suitable for use in the presence of a flammable anesthetic mixture No AP or APG protection Mattress Specification model Jee 78 7 x 35 4 x 8 200 x 90 x 20 3 cm Weight z21B 00kg 20 x 8 bladders Cover CE cens TT 18 750000 INS LAB RevC11 WARRANTY GF Health Products Inc warrants the Lumex AltaDyne 750000 Alternating Pressure Low Air Loss Mattress System for a period of twelve months for defects in workmanship and materials
13. wer cord into a properly grounded electrical outlet 750000 INS LAB RevC11 13 OPERATION 1 Turn the power switch to the ON position OFF Power 2 Adjust the pressure adjust knob to the maximum position Info Set the pressure adjust knob to the maximum position for the quickest inflation at set up the mattress can then be adjusted to the desired pressure 3 The pump will begin delivering air into the mattress While the g Low Pressure mattress is filling the low pressure indicator yellow LED will illuminate 4 When the selected pressure level is reached the low Normal Pressure pressure indicator will de illuminate and the normal pressure indicator green LED will automatically illuminate 5 Replace all sheets blankets and pillows on the bed PRESSURE ADJUSTMENT Generally a lighter patient will need a lower softer setting while a heavier patient will need a higher firmer setting but pressure adjustment must ultimately be based on the patient s weight distribution A short stocky person may be the same weight as a tall thin person but their settings will not be the same The mattress should be firm enough to support the patient yet soft enough so the patient will sink down to eliminate pressure points Test the pr

Download Pdf Manuals

image

Related Search

Related Contents

Conversions Technology CTVGA-HDMI video converter  Bedienungsanleitung Allgemein  Sophie Talbot - CPM interactiv  Atlas D K 130 Unit  User Manual  nüvi® 1490TV Manuale Utente  FICHA DE DATOS DE SEGURIDAD (REACH  Black & Decker 4011 Instruction Manual  OS Terrain 5 - Digimap Home Page  HG-DOx User Manual  