Home
GE V21W Installation Guide
Contents
1. GE Lighting Solutions READ THOROUGHLY BEFORE INSTALLING A WARNING Risk of electric shock e Turnpower off before servicing seeinstructions A WARNING Risk of fire e Use supply wire specified on nameplate GENERAL Versaflood II Wallighter This luminaire is designed for outdoor lighting service and should not be used in areas of limited ventilation or in high ambient temperature enclosures Best results will be obtained if installed and maintained according to the following recommendations Versaflood II Industrial Wallighter This luminaire is designed for elevated ambient outdoor or indoor lighting service See nameplate for ambient ratings versus wattage Best results will be obtained if installed and maintained according to the following recommendations UNPACKING This luminaire has been properly packed so that no parts should have been damaged during transit Inspect to confirm INSTALLATION A CAUTION Unit will fall if not installed properly e Follow installation instructions 1 Remove door by loosening the door and hinge screws and opening at least 30 and pushing or bumping the door toward the hinge so that the hinge springs slide over the hinge pin 2 Remove the reflector by removing the center screw loosening the two flange screws and disconnecting the socket connector 3 Remove the protective insulation shield GEH 3897D INSTRUCTIONS Versaflood II Wallighter 4 Versaf
2. cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation operation or maintenance Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser s purposes the matter should be referred to GE Lighting Solutions Verify that supply voltage is correct by comparing it to nameplate If unit is designated as multivolt or multiwatt follow specific instruction Do not remove insulated connectors from wires not needed for required voltage connection IF SINGLE VOLTAGE All single voltage ballasts are pre wired such that user need only connect the supply conductors IF MULTIVOLT 120 208 240 277 volts Connect the ballast lead with the insulated terminal to the desired voltage terminal as indicated on the ballast terminal nameplate IF MULTIWATT Multiwatt ballasts are available in various combinations of wattage See wiring instructions on wiring tag inside the luminaire FINAL ASSEMBLY To assemble luminaire follow the steps below 1 Engage the quick disconnect plug 2 Install reflector 3 Install lamp 4 Align door with hinges and pull or bump to snap spring over the pin Tighten the three captive screws LAMP INSTALLATION Use only lamps specified on nameplate Observe lamp manufacturer s recommendations and restric tions on lamp operation particularly ballast type b
3. ing in loose connections and intermittent operation 438 in 11mm DIA KNOCKOUT 4 TD 19 000 in 483mm i 2 250 in 57mm 750 in 19mm 4 500 in GE Lighting Solutions e 1 888 MY GE LED e www gelightingsolutions com 1 888 69 43 533 GE Lighting Solutions is a subsidiary of the General Electric Company Evolve and other trademarks belong to GE Lighting Solutions The GE brand and logo are trademarks of the General Electric Company 2011 GE Lighting Solutions Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions 35 201578 C7 11 99
4. lood Wallighter For surface mounting there are four 0 438 in 11mm diameter knockouts provided and a 0 875 22mm diameter knockout for the back wiring entrance This unit is also provided with three inch diameter threaded conduit entrances one at the top and one on each side Versaflood II Industrial Wallighter For surface mounting there are four 0 438 in 11mm diameter knockouts provided Back wiring entrance is not permitted This unit is also provided with three 0 75 in 19mm diameter threaded conduit entrances one at the top and one on each side NOTE Do not use the rear outlet box wiring entrance with series V2IW fixtures PHOTOELECTRIC CONTROLS Versaflood II Wallighter Only Photoelectric control receptacle if present should be oriented before control is installed Loosen the two holding screws and rotate receptacle until NORTH is directed as near as possible to true North Tighten holding screws and install control WIRING To assure against heat damage to leads position all leads to prevent contact with reflector Make all electrical connections in accordance with the National Electrical Code and any applicable local code requirements CONNECTIONS FOR SINGLE AND DUAL RATED UNITS Terminals are readily accessible on the terminal board and will accept No 14 through No 6 wire Attach the service leads to the terminal board as shown on the luminaire nameplate These instructions do not purport to
5. urning position etc 3 4 in THREADED CONDUIT ENTRANCE ONE TOP ONE EACH SIDE PE WHEN REQUIRED 8 125 in 206mm 875 in 22mm DIA KNOCKOUT WIRE ENTRANCE 1 Versaflood II Wallighter Only 10 000 in 251mm 254mm 5 000 in 127mm 17 375 in 441mm Lamp Tightness Mogul Base Lamp The lamp should be securely inserted to the NEMA EEI specified torque of 35 inch pounds which is best achieved by very firm tightening sufficient to fully depress and load the center contact of the socket Lamp Tightness Medium Base Lamp The lamp shouldbe tightened to a light firmness sufficient to depress the center contact MAINTENANCE A CAUTION Risk of burn Allow lamp fixture to cool before handling A WARNING Risk of burn e Do not touch operating luminaire For cleaning the reflector and door glass use a soap cleaner detergent or a solution of the same 6 10 ounces per gallon of water or the manufacturers recommendations which is essentially neutral oH approximately 6 to 8 nonabrasive and which contains no chlorinated or aromatic hydrocarbons Wash thoroughly in this solution using a soft cloth or brush if necessary Rinse in clean cold water drain and wipe dry When servicing luminaire always be sure to mate polar ized disconnect plugs only with each other Do not use oversize test prods in female portion of disconnect plug as sleeves will be deformed result
Download Pdf Manuals
Related Search
Related Contents
Manuale utente GPS Discover your IHP en Date / Time " " Ref 見る - JVCケンウッド Sweex Wireless Mouse Red USB Our Lady of Lourdes Hospital Executive Summary Course Description: This course is an exploration of the theories and BETRIEBSANLEITUNG „i-CHARGE MOBILE PREMIUM“ Betriebsanleitung Operating instructions LG Electronics 42PG69 Flat Panel Television User Manual AdvanLED Lighting Copyright © All rights reserved.