1. 80V f Mounting rT J inserts 2 lifi 3 Hf 4 A pate Chain or Cable Mounting Please O Direct Mounting Hang two chains 5 Indirect Mounting for Uplighting follow all UL NEC and minimum load cables from a structural member Hang two chains cables from a rating guidelines when selecting and of the ceiling Fixture must be structural member of the ceiling installing a cable or chain supported independently of an Fixture must be supported NOTE When selecting chain a outlet box Tighten adjustment independently of an outlet box joint in a circular chain link shall screws on all four mounting inserts Attach chain or cable to eye bolt be welded A joint in a chain link of then attach chain or cable to mounts on both ends of fixture another shape shall not be located mounting inserts on both ends of within 30 degrees of the vertical fixture unless welded Electrical Connections 120 277V Option power input from top A Install 1 2 conduit or B install AC power cord with strain relief B Power cord Option power input from side Remove knockout in Connect the green ground black line and white endcap and A Install 1 2 conduit or B install AC power neutral wires of the AC line to the similarly colored cord with strain relief Plug unused hole on top with wires of the fixture s power supply using UL listed appropriate fitting wire connectors Re attach endcap Electrical Connections 347 480V A I
2. GE Installation Guide Lighting Albeo LED Luminaire Modular High amp Low Bay Lighting ABH2 series Features e 5 year warranty e Damp location rated BEFORE YOU BEGIN Read these instructions completely and carefully AX WARNING AVERTISSEMENT RISK OF ELECTRIC SHOCK RISQUES DE DECHARGES ELECTRIQUES e Turn power off before inspection installation or removal e Coupez l alimentation avant d inspecter installer ou d placer le luminaire e Properly ground electrical enclosure e Assurez vous de correctement mettre la terre le bo tier d alimentation lectrique RISK OF FIRE RISQUES D INCENDIE e Follow all NEC and local codes e Respectez tous les codes NEC et codes locaux e Use only UL or IEC approved wire for input output connections e N utilisez que des fils approuv s par UL ou IEC pour les entr es sorties de Minimum size 18 AWG connexion Taille minimum 18 AWG This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation CAN ICES 3 A NMB 3 A This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed o provide reasonable protection against harmful interference when the equipment is operated in a com
3. f the wires they are connected to e Check that all wire connectors are properly connected e Verify that your input voltage is within specs e If you are using any additional controls IE wireless controls motion sensors please also verify that those are working properly and that the unit is setup to interface with the controllers Mounting insert slides e Check that the mounting insert is properly tightened using the adjustment screws provided from side to side Endplate of Pendant Mount Kit e Check that the top plate is properly slotted in main bracket does not snap in place e Check that endplate tabs are properly aligned in pendant mount bracket assembly e Check that endplate is pushed firmly into place GE Lighting e 1 888 MY GE LED 1 888 69 43 533 www gelighting com GE Lighting LLC is a subsidiary of the General Electric Company The GE brand logo and Albeo are trademarks of the General Electric Company 2013 GE Lighting LLC Information provided is subject to change without notice All values are design or typical values when measured under laboratory conditions ALB014 012114
4. mercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Save These Instructions Use only in the manner intended by the manufacturer If you have any questions contact the manufacturer Prepare Electrical Wiring Electrical Requirements e The LED driver must be supplied with 120 480 VAC 50 60 Hz per product label and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker Grounding Instructions e The grounding and bonding of the overall system shall be done in accordance with National Electric Code NEC Article 600 and local codes imagination at work Unit Installation Carefully unpack unit and properly inspect for defects before installing Wear work gloves to prevent dirt and oil from being transferred to the luminaire Choose a mounting method chain or cable rod mount or pendant mount Chain or cable is covered here Other options are covered in the section Optional Mounting Methods Fixture Weight Attach to A Attach to structural member g ural member ABH2 series Max Weight Ibs JN i LED Modules 120 277V__347 4
5. nstall 1 2 conduit or B install AC power cord with strain relief 3 Connect AC line to fixture s power supply using UL listed O Re attach endcap wire connectors Green to green ground red to black line and black to white neutral Optional Mounting Methods fo ite Rod Mount Kit Attach to structural member Attach two rod mount brackets to fixture using four Secure 1 2 threaded rods into structural members in 10 32 x 3 8 pan head screws per bracket ceiling Place a nut on each threaded rod where fixture should hang Slide fixture onto threaded rods and tighten second nut onto rods to secure fixture 0 Ne N Pendant Mount Kit NOTE Pendant Mount Kit cannot be used with the 6 module fixture Attach pendant mount bracket assembly to four mounting inserts on the fixture with 8 10 32 x 3 8 through conduit top plate and locking nut if used Philips pan head screws Connect the AC input wires to the fixture wires coming from the strain relief in the main bracket assembly bottom plate cS Slide top plate into main bracket Align top tabs of end 4 Fasten endplate to bracket with a 8 32 x 1 4 Philips pan plate with slots in main bracket and push endplate into head screw Fasten endplate to mounting hub with a place 6 32 x 1 2 hex head screw Troubleshooting Symptom Solution Luminaire will not turn on e Check that the color of the supply side wires match the color o
Download Pdf Manuals
Related Search
Related Contents
0Dht8 - Ophta France Betriebsanleitung 95-2554 - Detector Electronics Corporation. ビタCシャワー 取扱説明書 INSTRUCTIONS FOR USE MODE D`EMPLOI Boss Audio Systems MR1400W User's Manual BENDIX BW2478F User's Manual Foundry Networks AR1202 User's Manual Emini B&W_manual_english_website BRT2640 - Migros Copyright © All rights reserved.